U-shaped plan of commercial- residential building in Bhuj
description
Transcript of U-shaped plan of commercial- residential building in Bhuj
![Page 1: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/1.jpg)
U-shaped plan of commercial- residential building in Bhuj
![Page 2: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/2.jpg)
Open ground story collapse of short wing of same building
![Page 3: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/3.jpg)
Shear cracking in infill masonry in weak cement mortar and sandstone blocks
![Page 4: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/4.jpg)
Collapse of a partially open ground story building in Bhuj,coupled with vertical split of the building at midline
![Page 5: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/5.jpg)
Collapse of the upper stories of this Gandhidham apartment building was due to plan irregularity
![Page 6: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/6.jpg)
Collapse of corner owingto failure of diaphragm at the reentrant
![Page 7: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/7.jpg)
damage to perimetercolumns of building with varying lateral
![Page 8: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/8.jpg)
Damage to small servicewater tank on top of RC frame building
![Page 9: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/9.jpg)
Open ground story buildings with masonry infills only in the upper storiesare subject to severe deformation demands on ground story columns.
![Page 10: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/10.jpg)
Shear cracking of non-ductilecolumns of an open ground story buildingin Bhuj
![Page 11: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/11.jpg)
RC elevator cores savedmany buildings with open ground stories
![Page 12: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/12.jpg)
RC columns sustainedsevere damage. Shutters were down atthe time of the earthquake
![Page 13: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/13.jpg)
Many open groundstory buildings did not collapse, butsustained severe damage to thecolumns in the ground story
![Page 14: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/14.jpg)
Shear failures incolumns due to inadequateconfinement reinforcement
![Page 15: U-shaped plan of commercial- residential building in Bhuj](https://reader036.fdocuments.us/reader036/viewer/2022070416/568151dd550346895dc0158a/html5/thumbnails/15.jpg)
Intermediate storycollapse in the 6 story building inBhuj