2
N-PE: Voltage protection level U p at U oc of 6 kV 1.2/50 μs and I sc of 3 kA 8/20 μs (per mode) 640 V 2 L-PE: Voltage protection level U p at U oc of 6 kV 1.2/50 μs and I sc of 3 kA 8/20 μs (per mode) 712 V 2 Transient overvoltage performance L-N Transient overvoltage performance L-PE Transient overvoltage performance N-PE Transient Overvoltage Performance Test Certificate Surge Protective Device (SPD): Furse ESP 415 M1 For installation in Havells distribution boards: Type ‘B’ TPN: PSB41, PSB61, PSB61M, PSB81, PSB121, PSB121M, PSB181, PSB181M The Havells/Furse solution combines best-in-class mains power distribution with transient overvoltage protection ensuring controlled and verified SPD installation in line with IET Wiring Regulations 17th Edition, BS 7671:2008(+A1:2011), for optimal protection of installed equipment. Installed performance test: IEC 61643-11 Class III Combination waveform 6 kV (1.2/50 μs voltage) 3 kA (8/20 μs current) Date: Transient specification (at SPD terminals) Voltage protection level U p at U oc of 6 kV 1.2/50 μs and I sc of 3 kA 8/20 μs (per mode) 600 V 1 All testing performed in accordance with IEC 61643-11 Class III test 6 kV (1.2 μs voltage) 3 kA (8/20 μs current) for verifying SPD transient overvoltage protective performance at terminal equipment level. 2 Typical values, subject to manufacturing component tolerances. Essential detail relates to voltage protection level U p <715 V for effective protection below impulse immunity/susceptibility of equipment. Transient specification (installed performance - SPD to Type ‘B’ TPN board) L-N: Voltage protection level U p at U oc of 6 kV 1.2/50 μs and I sc of 3 kA 8/20 μs (per mode) 708 V 2 Target voltage protection level U p : (2 x peak operating voltage, 230 V AC system) 715 V This document certifies that the Furse ESP 415 M1 SPD has been installed on the Havells Type ‘B’ TPN distribution board in accordance with best practice principles to IET Wiring Regulations 17th Edition, BS 7671:2008(+A1:2011) and tested to achieve the voltage protection levels (U p ) shown above. 1 The maximum transient overvoltage let-through the SPD throughout the test (±5%), phase to neutral, phase to earth and neutral to earth. Havells UK: Longbow House, 14-20 Chiswell Street, London, EC1Y 4TW Tel: 0843 2275 388 Furse: Wilford Road, Nottingham, NG2 1EB Tel: 0115 964 3700 Signed: Keith Herrington R&D Manager, Furse ESP 12th July 2012

Transcript of TransientOvervoltagePerformance TestCertificate Tech Spec.pdf · Protectionstandard,BSEN/IEC62305....

Page 1: TransientOvervoltagePerformance TestCertificate Tech Spec.pdf · Protectionstandard,BSEN/IEC62305. BS7671providesguidancethroughSections443&534ontheSPDselectionandinstallationrequirementsforACpowersuppliestoensure

N-PE: Voltage protection level Up at Uoc of 6 kV 1.2/50 µsand Isc of 3 kA 8/20 µs (per mode) 640 V2

L-PE: Voltage protection level Up at Uoc of 6 kV 1.2/50 µsand Isc of 3 kA 8/20 µs (per mode) 712 V2

Transient overvoltage performance L-N

Transient overvoltage performance L-PE

Transient overvoltage performance N-PE

Transient Overvoltage PerformanceTest Certificate

Surge Protective Device (SPD):

Furse ESP 415 M1

For installation in Havells distribution boards:

Type ‘B’ TPN: PSB41, PSB61, PSB61M, PSB81, PSB121,PSB121M, PSB181, PSB181M

The Havells/Furse solution combines best-in-class mains powerdistribution with transient overvoltage protection ensuringcontrolled and verified SPD installation in line with IET WiringRegulations 17th Edition, BS 7671:2008(+A1:2011), for optimalprotection of installed equipment.

Installed performance test:IEC 61643-11 Class III Combination waveform6 kV (1.2/50 µs voltage) 3 kA (8/20 µs current)

Date:

Transient specification (at SPD terminals)

Voltage protection level Up at Uoc of 6 kV 1.2/50 µsand Isc of 3 kA 8/20 µs (per mode) 600 V1

All testing performed in accordance with IEC 61643-11 Class III test 6 kV (1.2 µs voltage) 3 kA (8/20 µs current) forverifying SPD transient overvoltage protective performance at terminal equipment level.

2 Typical values, subject to manufacturing component tolerances. Essential detail relates to voltage protection levelUp <715 V for effective protection below impulse immunity/susceptibility of equipment.

Transient specification (installed performance - SPD to Type ‘B’ TPN board)

L-N: Voltage protection level Up at Uoc of 6 kV 1.2/50 µsand Isc of 3 kA 8/20 µs (per mode) 708 V2

Target voltage protection level Up:(2 x peak operating voltage, 230 V AC system) 715 V

This document certifies that the Furse ESP 415 M1 SPD hasbeen installed on the Havells Type ‘B’ TPN distribution board inaccordance with best practice principles to IET Wiring Regulations17th Edition, BS 7671:2008(+A1:2011) and tested to achieve thevoltage protection levels (Up) shown above.

1 The maximum transient overvoltage let-through the SPD throughout the test (±5%), phase to neutral, phase to earthand neutral to earth.

Havells UK: Longbow House, 14-20 Chiswell Street, London, EC1Y 4TW Tel: 0843 2275 388Furse: Wilford Road, Nottingham, NG2 1EB Tel: 0115 964 3700

Signed:

Keith HerringtonR&D Manager, Furse ESP

12th July 2012

Page 2: TransientOvervoltagePerformance TestCertificate Tech Spec.pdf · Protectionstandard,BSEN/IEC62305. BS7671providesguidancethroughSections443&534ontheSPDselectionandinstallationrequirementsforACpowersuppliestoensure

NOVolt free contact

ESP 415 M1STATUS INDICATION

ELECTRONIC SYSTEMS PROTECTION

Made by W J Furse & Co Ltd, ESP Division, Wilford Road, Nottingham, NG2 1EB, UK

L1

L1 L2 L3 N

L1

L2

L3

N

NWARNING

PATENTAPPLIED

FOR

If lit / flashing disconnectunit & check Neutral to

Earth supply voltage

L2 L3

NC C

GREEN FULL PROTECTION

NO PROTECTION

REDUCED PROTECTION (replace unit)GREEN & RED

RED

Let-through voltage 600V

3 phase/50Hz

(Live to Neutral, Live to Earth & Neutral to Earth)

Vmax 480Vrms

OCPD(SUPPLY)

OCPD (SPD)

Technical InformationSensitive and critical electrical equipment must be protected against transient overvoltages due to atmospheric origin orelectrical switching events in accordance with IET Wiring Regulations 17th Edition, BS 7671:2008(+A1:2011), and LightningProtection standard, BS EN/IEC 62305.

BS 7671 provides guidance through Sections 443 & 534 on the SPD selection and installation requirements for AC power supplies to ensurea satisfactory electrical installation, including:

SPD installation as close as practicable to the origin of the supply, generally at the main distribution board after the meter, tocounter the high level transient overvoltages expected at the service entrance (Clause 534.2.1)

SPD installation as close as practicable to terminal equipment, i.e. at sub-distribution boards for sensitive equipment, or locallyfor critical equipment (Clause 534.2.1)

Connecting leads as short as possible between the SPD, live conductor(s) and the protective conductor, with an ideal total leadlength not more than 0.5 m (but in no case more than 1 m), to minimise risk from additive inductive voltages (Clause 534.2.9)

Installation of multiple coordinated SPDs at appropriate points (main distribution and at subsequent sub-distribution boards) wherethe distance from the SPD to terminal equipment exceeds 10 m, to counter potential voltage oscillations damaging equipment(Clauses 534.2.3.1 & 534.2.3.4.4)

SPD performance suitable to protect the impulse withstand voltage of sensitive electrical equipment (to Tables 44.3 & 44.4 ofBS 7671) and the impulse immunity of critical electrical equipment (impulse immunity calculated at twice the peak operating voltageof the electrical system, i.e. approximately 715 V for 230 V AC systems) (Clause 534.2.3.1.1)

Full Mode SPD capability to protect against transient overvoltages between all conductor combinations (L-N, L-PE, N-PE), forcontinuous operation of electrical equipment (Clause 534.2.2 Note 1)

The combination of Havells Type ‘B’ TPN distribution board with Furse ESP 415 M1 SPD ensures an optimal, controlled and verified solutionto transient overvoltages, removing all installation variables which would reduce SPD performance:

The Furse ESP 415 M1 is fully tested to IEC 61643 Class III equipment level test to achieve let-through voltage at the SPD’s terminalsnot exceeding 600 V, with installed performance proven below the impulse immunity/susceptibility of equipment (see previous page).Note installed performance of SPDs always exceeds the tested performance at an SPD’s terminals due to additive inductive voltagedrop on the SPD’s connecting leads

The SPD is supplied with all connecting leads specifically sized to minimise additive inductive voltage drop, for controlled installationin accordance with BS 7671

The SPD provides enhanced protection (as defined by BS EN 62305) with Full Mode capability and Combined Type 1+2+3performance for high quality, effective transient overvoltage protection

The SPD coordinates with all other Furse SPDs installed onsite

Installation diagrams

Connection of SPD to active conductors andprotective conductor. Installation shall includeovercurrent protective devices (OCPDs) on supplyconductor(s) and SPD live connecting lead(s). Ensuresufficient discrimination between OCPDs.

Diagrammatical illustration of each connection between Furse ESP 415 M1 SPD and Havells Type ‘B’ TPN distribution boardshown above, with image showing completed installation image in bottom right position.

Havells UK: Longbow House, 14-20 Chiswell Street, London, EC1Y 4TW Tel: 0843 2275 388Furse: Wilford Road, Nottingham, NG2 1EB Tel: 0115 964 3700

NO

Vo

ltfr

eeco

nta

ct

ES

P41

5M

1S

TAT

US

IND

ICA

TIO

N

EL

EC

TR

ON

ICS

YS

TE

MS

PR

OT

EC

TIO

N

Mad

eb

yW

JF

urs

e&

Co

Ltd

,ES

PD

ivis

ion

,Wilf

ord

Ro

ad,N

ott

ing

ham

,NG

21E

B,U

K

L1

L1

L2

L3

N

NW

AR

NIN

G

PA

TE

NT

AP

PL

IED

FO

R

Iflit

/fla

shin

gd

isco

nn

ect

un

it&

chec

kN

eutr

alto

Ear

thsu

pp

lyvo

ltag

e

L2

L3

NC

C

GR

EE

NF

UL

LP

RO

TE

CT

ION

NO

PR

OT

EC

TIO

N

RE

DU

CE

DP

RO

TE

CT

ION

(rep

lace

un

it)

GR

EE

N&

RE

D

RE

D

Let

-th

rou

gh

volt

age

600V

3p

has

e/50

Hz

(Liv

eto

Neu

tral

,Liv

eto

Ear

th&

Neu

tral

toE

arth

)

Vm

ax48

0Vrm

s

NO

Vo

ltfr

eeco

nta

ct

ES

P41

5M

1S

TAT

US

IND

ICA

TIO

N

EL

EC

TR

ON

ICS

YS

TE

MS

PR

OT

EC

TIO

N

Mad

eb

yW

JF

urs

e&

Co

Ltd

,ES

PD

ivis

ion

,Wilf

ord

Ro

ad,N

ott

ing

ham

,NG

21E

B,U

K

L1

L1

L2

L3

N

NW

AR

NIN

G

PA

TE

NT

AP

PL

IED

FO

R

Iflit

/fla

shin

gd

isco

nn

ect

un

it&

chec

kN

eutr

alto

Ear

thsu

pp

lyvo

ltag

e

L2

L3

NC

C

GR

EE

NF

UL

LP

RO

TE

CT

ION

NO

PR

OT

EC

TIO

N

RE

DU

CE

DP

RO

TE

CT

ION

(rep

lace

un

it)

GR

EE

N&

RE

D

RE

D

Let

-th

rou

gh

volt

age

600V

3p

has

e/50

Hz

(Liv

eto

Neu

tral

,Liv

eto

Ear

th&

Neu

tral

toE

arth

)

Vm

ax48

0Vrm

s

NO

Vo

ltfr

eeco

nta

ct

ES

P41

5M

1S

TAT

US

IND

ICA

TIO

N

EL

EC

TR

ON

ICS

YS

TE

MS

PR

OT

EC

TIO

N

Mad

eb

yW

JF

urs

e&

Co

Ltd

,ES

PD

ivis

ion

,Wilf

ord

Ro

ad,N

ott

ing

ham

,NG

21E

B,U

K

L1

L1

L2

L3

N

NW

AR

NIN

G

PA

TE

NT

AP

PL

IED

FO

R

Iflit

/fla

shin

gd

isco

nn

ect

un

it&

chec

kN

eutr

alto

Ear

thsu

pp

lyvo

ltag

e

L2

L3

NC

C

GR

EE

NF

UL

LP

RO

TE

CT

ION

NO

PR

OT

EC

TIO

N

RE

DU

CE

DP

RO

TE

CT

ION

(rep

lace

un

it)

GR

EE

N&

RE

D

RE

D

Let

-th

rou

gh

volt

age

600V

3p

has

e/50

Hz

(Liv

eto

Neu

tral

,Liv

eto

Ear

th&

Neu

tral

toE

arth

)

Vm

ax48

0Vrm

s

NO

Vo

ltfr

eeco

nta

ct

ES

P41

5M

1S

TAT

US

IND

ICA

TIO

N

EL

EC

TR

ON

ICS

YS

TE

MS

PR

OT

EC

TIO

N

Mad

eb

yW

JF

urs

e&

Co

Ltd

,ES

PD

ivis

ion

,Wilf

ord

Ro

ad,N

ott

ing

ham

,NG

21E

B,U

K

L1

L1

L2

L3

N

NW

AR

NIN

G

PA

TE

NT

AP

PL

IED

FO

R

Iflit

/fla

shin

gd

isco

nn

ect

un

it&

chec

kN

eutr

alto

Ear

thsu

pp

lyvo

ltag

e

L2

L3

NC

C

GR

EE

NF

UL

LP

RO

TE

CT

ION

NO

PR

OT

EC

TIO

N

RE

DU

CE

DP

RO

TE

CT

ION

(rep

lace

un

it)

GR

EE

N&

RE

D

RE

D

Let

-th

rou

gh

volt

age

600V

3p

has

e/50

Hz

(Liv

eto

Neu

tral

,Liv

eto

Ear

th&

Neu

tral

toE

arth

)

Vm

ax48

0Vrm

s

NO

Vo

ltfr

eeco

nta

ct

ES

P41

5M

1S

TAT

US

IND

ICA

TIO

N

EL

EC

TR

ON

ICS

YS

TE

MS

PR

OT

EC

TIO

N

Mad

eb

yW

JF

urs

e&

Co

Ltd

,ES

PD

ivis

ion

,Wilf

ord

Ro

ad,N

ott

ing

ham

,NG

21E

B,U

K

L1

L1

L2

L3

N

NW

AR

NIN

G

PA

TE

NT

AP

PL

IED

FO

R

Iflit

/fla

shin

gd

isco

nn

ect

un

it&

chec

kN

eutr

alto

Ear

thsu

pp

lyvo

ltag

e

L2

L3

NC

C

GR

EE

NF

UL

LP

RO

TE

CT

ION

NO

PR

OT

EC

TIO

N

RE

DU

CE

DP

RO

TE

CT

ION

(rep

lace

un

it)

GR

EE

N&

RE

D

RE

D

Let

-th

rou

gh

volt

age

600V

3p

has

e/50

Hz

(Liv

eto

Neu

tral

,Liv

eto

Ear

th&

Neu

tral

toE

arth

)

Vm

ax48

0Vrm

s

L1 connection

L2 connection

N connection

PE connection

L3 connection