SECTION 1General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Assessing the Opening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 2 TMW 453 Framing Members / Accessories . . . . . . . . . . . . . . . . . P1 - P4
SECTION 3 Fabrication Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F1 - F14
SECTION 4 Sealant and Erection Procedures . . . . . . . . . . . . . . . . . . . . . . . . . S1
Elevations to Illustrate Typical Conditions . . . . . . . . . . . . . . . . . . . S2 - S3Sealant and Erection Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . S4 - S17
SECTION 5 Glazing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G1 Glass Formula and Glazing Chart . . . . . . . . . . . . . . . . . . . . . . . . . . G2
This document was developed by Pittco Architectural Metals, Inc. as advisory information and published as apublic service for our customers. Pittco disclaims all warranties with regard to this information, including allimplied warranties of merchantability and fitness. In no event shall Pittco be liable for any damages whatsoeverfrom the use, application or adaptation of materials published herein. It is the sole responsibility of theuser/installer to evaluate the accuracy, completeness or usefulness of any information, opinions, advice or othercontent published herein. Please consult your Pittco representative if you have questions about this document.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
GENERAL INSTALLATION NOTES
G1
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
2
SECTION 1 - GENERAL INSTALLATION NOTES:
GENERAL CONSTRUCTION NOTES
· Don't drop products during handling. Dropping or striking members against any solid objects will damage the finish and may cause fabricated jointsand applied sealants to fail. Stack with adequate separation so materials will not rub together. Use interleaving material if needed. Cardboardwrapped or paper interleaved material must be kept dry. Store products off the ground. Protect against the elements, and damage by otherconstruction trades.
· Keep material away from water, mud, and construction materials. Prevent cement, plaster or other materials from damaging the finish.
· Protect the erected framing by wrapping with Kraft paper or by erecting sheet plastic or canvas splatter screens. Cement, plaster, terrazzo and otheralkaline solutions are very harmful to the finish. Under no circumstances allow these materials to dry on the finish or permanent staining will occur.Remove immediately with mild soap and water.
· All materials should be checked for quality and quantity upon receipt, Pittco must be notified immediately of any discrepancies. Check to make sureyou have the required shims, supplies, sealants, and tools necessary for installation.
· Any material substitutions must be of equal or greater quality.
· Sealants must be compatible with all materials with which they have contact, including other sealant surfaces. Consult with your sealant supplier forrecommendations relative to shelf life, compatibility, priming, tooling, adhesion, safety, etc.
· "Fastening" will mean any method of securing one part to another or to adjacent materials. These instructions will specify only those fasteners usedwithin the system. (Perimeter or anchor fasteners are normally not specified due to varying surrounding conditions.)
· Glazing gaskets should be cut long to account for shrinkage. They should be installed by inserting both corners first, then the center of the gasketfollowed by the quarter points. Continue subdividing the opening until the gasket can be easily and completely rolled into the gasket pocket. Gasketsinstalled in this manner will close at the corners and will not shrink or pull back at the ends.
· Isolate all aluminum to be placed directly in contact with concrete with a heavy coat of bituminous paint. Isolate aluminum from incompatiblematerials with plastic shims, paint finish, or zinc rich primer.
· Any horizontals will act as collectors of infiltrated water and will direct water to the vertical pockets that will act as downspouts. Water deflectors mustbe installed above all lights of glass to insure that water is directed from the downspouts to the outside of the building. Sill flashing is not required inall applications, when flashing is required end dams should be utilized.
· Take field measurements BEFORE fabrication to ensure a proper fit. A minimum perimeter shim space of 3 4" is required at the head, and 12" sill andjambs. Joint at head may be increased to accommodate building movements and / or thermal expansion with a "T" anchor. Joint should be twice thetotal anticipated movement.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 1 - General Information
3
DL
WL
DL
WL
DL
WL
WL
DL
SPLICE
TYPE
A(S
ingl
e Sp
an)
TYPE
B(M
ultip
le S
pan
< 2
6 ft)
TYPE
C(M
ultip
le S
pan
w/S
plic
e - O
verh
ang)
Anchor Conditions/Locations
FRAM
E SI
ZE
MAXIMUM ROUGH OPENING
FRAME SIZE
MAX
IMUM
ROU
GH O
PENI
NG
ACTUAL OPENING
ACTU
AL O
PENI
NG
MINIMUM ALLOWANCE FOR SEALANT
SIZING THE FRAMING
ANCHOR TYPES AND LOCATIONS
1. Measure The Opening:
Before fabricating material, an accurate frame size should be determinedby physically measuring the actual dimensions of the intended opening.Because of construction tolerances and construction practices, the actualopening may not be in total accordance with the approved shop drawings.
· Measure the width of the opening in several places to determine theminimum opening width.
· Measure the height of the opening in several places to determine theminimum opening height.
· Check level and plumb of the opening and adjust width and heightmeasurements accordingly.
2. Determine The Frame Size:
· After determining the maximum rough opening width, subtract twicethe allowance for perimeter jamb sealant to determine the requiredframe width.
· After determining the maximum rough opening height, subtract theallowance for perimeter sealant at the sill and the allowance forperimeter sealant at the head to determine the required frame height.
3. Determine Anchor Conditions and Locations:
· Review the opening conditions to determine the type of anchoringrequired and the location of the anchors.
· Assess the surrounding structure to verify that if the type of anchorsshown on the shop drawings can be correctly installed.
· Note anchor types at each condition which will be used duringinstallation of the wall.
· Make sure the shop drawings reflect your notes before fabricating theframe.
DETERMINING THE FRAME SIZE BY MEASURING THEBUILDING OPENING AND CHECKING THE ANCHOR TYPESAND LOCATIONS BEFORE FABRICATION CAN HELPAVOID COSTLY FABRICATION ERRORS.
CHECK DIAGONALSFOR SQUARENESS
WL
bed frame
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
4
53-454
52-481
53-468
FRAMING MEMBERS
53-451
53-450
53-463
53-464
53-500
53-507
52-506
Head/Sill(Use with 52-481)
Mullion ClosureFor Verticals and Horizontals
IntermediateHorizontal
Jamb Mullion
Vertical Mullion(Use with 52-481)
Vertical MullionHeavy Wall
(Use with 52-481)
Expansion MullionMale HalfHeavy Wall
(Use with 52-256)
SSG Vertical Mullion(Use with 52-481)
SSG Expansion MullionMale HalfHeavy Wall
(Use with 52-506)
SSG Expansion MullionFemale Half
(Use with 52-507)
53-467Head Horizontal(Inside Set)
53-457Expansion Mullion
Male Half(Use with 52-456)
52-456Expansion Mullion
Female Half(Use with 53-457 and 53-464)
53-518SSG Horizontal
52-490
52-492
52-540
90° Outside CornerHalf Mullion
(2 Req'd)
135° OutsideCorner Half Mullion
(2 Req'd)
90° SSG OutsideCorner Half Mullion
(2 Req'd)
52-542135° SSG OutsideCorner Half Mullion
(2 Req'd)
52-486Glass Stop(1" Glazing)
52-487Glass Stop(1/4" Glazing)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
Component Parts
P1
19-045
19-183
52-001
52-009
COVERS AND ADAPTERS
14" Glazing Adapter
Corner MullionLock
58" Glazing Adapter
Full Pocket Filler
52-035Interior Glass Stop(1" Glazing)
52-034Interior Glass Stop(1/4" Glazing)
52-488Interior Trim(Use w/ 52-034 / 52-035)
52-019Horizontal Re-glaze
Adapter
52-046Face / Cover90° Outside Corner
52-022Face / Cover135° Outside Corner
52-04090° Outside Corner
Mullion Adapter
12-00390° Corner Angle
52-029Outside Corner
Interior Trim
Isolator ClipCorner Trim
78-350-5100
52-016Face / Cover
52-010Face / Cover2" x 5/8"
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
Component Parts
P2
Setting Block15/16" - 1 1/4" Glazing(2) Required per Lite
70-881-6300
ACCESSORIES
Setting Block1" SSG Glazing
(2) Required per Lite
12-818-6300
Setting Block1/4" SSG Glazing
(2) Required per Lite
12-803-6300
Setting Block Shelf1" SSG Glazing
(2) Required per Lite
52-041-4150
Setting Block Chair1" SSG Glazing
(2) Required per Lite
53-006-4150
Jamb SpliceAt Glass Stop Area
(Remove paper before installation)
16-775-4150
Cover Splice(53-014)
(Remove paper before installation)
12-305-4250
12-305-6250
Water Deflector(Remove paper before installation)
70-702-4153
Horizontal Water DamSSG Mullions
52-050-4150
52-272-4150
90° Corner Splice(2 Req'd)
52-273-4150
135° Corner Splice(2 Req'd)
Temporary Glass Retainer 88-088-5100
Vertical Mullion End Cap(Remove paper before installation)
70-702-4160
Cover End Cap(Top of Vertical)
72-944-4151
52-000Retainer
Retainer(Use W/ 52-465)
53-000
Expansion MullionSplice
53-471-4150
Jamb and MullionSplice
53-470-4150
Expansion MullionSplice
(SSG Mullion)
52-521-4150
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
Component Parts
P3
FASTENERS AND GASKETS
Dense Silicone Gasket SSG GlazingInterior Spacer
12-916-6300
Adhesive Backed Foam Tape1/16" x 1/4"
70-890-6300
# 10-16 x 1"PFH Screw
Type B Point
10-119-4200
Attach 52-042 SSG1/4" Glazing Adapter
1/4-20 x 3/4"Hex Head Bolt
SEMS ET Lockwasher
10-377-4200
Attach 52-009
# 10-24 x 1/2"PFH Screw
Type F Point
Attach TransomSash
10-147-4254
# 10-16 x 1/2"PPH Screw
Type B Point
Attach Splices10-153-
4254
# 12-14 x 3/4"HWH Screw
Tek 3 Point
Attach Splices andStiffeners
10-241-4200
# 10-16 x 1 1/2"PPH Screw
Type B Point
Attach Horizntals10-379-
4254
1/4-20 x 1 3/4"Hex Head Bolt
SEMS ET Lockwasher
10-508-4200
Attach Corner AdapterSSG Mullions
# 10-16 x 1/2"HWH Screw
Tek 2 Point
Attach HorizontalRetainers and Splices
10-752-4200
Anti-Walk Spacer Block(1/2" Wide for Typical Int. Mullion)
12-908-6350
Solid EPDM Glazing Gasket(See Glazing Chart)
12-513-6300
Solid EPDM Glazing Gasket(See Glazing Chart)
12-514-6300
Foam EPDM Glazing Gasket(Expansion Mullions)
12-515-6300
Solid EPDM Glazing Gasket(See Glazing Chart)
12-521-6300
Solid EPDM Glazing Gasket(See Glazing Chart)
12-522-6300
Solid EPDM Glazing Gasket(Perimeter Gasket)
12-527-6300
Solid EPDM Glazing Gasket(See Glazing Chart)
17-004-6300
Solid EPDM Glazing Gasket(See Glazing Chart)
17-012-6300
Solid EPDM Glazing Gasket(See Glazing Chart)
17-013-6300
3/8-16 x 3 1/2"HWH Bolt
Structural Anchor 10-164-4200
3/8-16 x 3"HWH Bolt
Structural Anchor 10-165-4200
Anti-Walk Spacer Block(1" Wide for Jamb and Split Mullion)
12-908-6351
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
Component Parts
P4
LENGTH
DIM.
LENGTH
DIM.
DIM.
LEFT SIDE OF VERTICAL SHOWNRIGHT SIDE APPLICATION OPPOSITE HAND
VERTICAL MULLION CLOSURE PLATES
.201 DIA. (7 DRILL)
BOTT
OM
53-451 53-450
BOTT
OM
RIGHT SIDE OF VERTICAL MULLIONS SHOWNLEFT SIDE APPLICATION OPPOSITE HAND
VERTICAL MULLIONS
1"
53-46453-457
52-456 &53-463
1"
52-481
.201 DIA. (7 DRILL)
BOTT
OM
DIM.
.201 DIA. (7 DRILL)
BOTT
OM
DIM.
LENGTH
DIM.
1"
DIM.
LENGTH
DIM.
.201 DIA. (7 DRILL)
1116"
516"
1116"
114"11
4"
1116" 11
16"
114"
1116"
916
"27
8"
278"
114"
1116"
1116"
516"
114"
1116"
278"
218" 11
4"
1116"
HORIZ. HORIZ.HORIZ.
218"
1116"
1116"
114"
1116"
114"
FAB FOR53-454
FAB FOR53-468
OR53-518
FAB FOR53-454
HORIZ. HORIZ. HORIZ.
FAB FOR
53-454
OR
53-467
FAB FOR
52-466
52-465
SIMILAR
FAB FOR
53-454
278"
HORIZ. HORIZ. HORIZ. HORIZ. HORIZ. HORIZ.
FAB FOR53-454
FAB FOR52-466
FAB FOR53-454
OR53-467
FAB FOR53-454
FAB FOR53-468
FAB FOR53-454
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F1FAB
CLOSURE ANGLE90° OUTSIDE CORNER
VERTICAL LENGTH
INTERIOR TRIM
VERTICAL LENGTH
90° & 135° OUTSIDE CORNER
VERTICAL LENGTH
CORNER LOCK STRIP
52-490
12-003
52-029
52-009
135° OUTSIDE CORNER52-492 52-492
1"
BOTT
OM
90° OUTSIDE CORNER52-490
1"
BOTT
OM
FAB FOR53-454
DIM.
LENGTH
DIM.
53-468FAB FOR FAB FOR
53-454
FAB FOR
53-467
53-454OR
LENGTH
DIM.
DIM.
FAB FOR
52-465SIMILAR
52-466 53-454FAB FOR
278"
278"
218"
1116"
1116"
114"
1116"
114"
1116"
114"
1116"
114"
516"
1116"
HORIZ. HORIZ. HORIZ.
HORIZ. HORIZ. HORIZ.
.201 DIA. (7 DRILL)
.201 DIA. (7 DRILL)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F2FAB
1932"
"A"
52-481
3364
"
3"
30°
30°
INTERIOR TRIMS & STOPS
53-454
52-035 52-034 52-488
53-454
OUTSIDE SET53-468
1332
"
114"
114"
30°
3"
HORIZONTAL RETAINER
HORIZONTAL FACE52-016
19-183
ADAPTORS IF REQUIRED
SILL HORIZONTALS
52-00119-045 114"
53-000
INTERMEDIATE HORIZONTALS
358"
INSIDE SET52-465 52-466
53-454 53-467
HEAD HORIZONTALS
53-454 53-467
358"
15°
OTHER HORIZONTALS 1 7/16" FOR ALL HORIZONTALS 52-465 & 52-466"A" DIM.=1 11/32" FOR
HORIZONTAL CLOSURE PLATE
1 1/4"
58"
358"
58"
114"
58"
1332
"
358"
58"
1332
"
11764"
11764"
VERT.
VERT.VERT.
VERT. VERT.
VERT.VERT.
SLOT ASREQUIRED
SLOT ASREQUIRED
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F3FAB
INTERIOR TRIMS & STOPS
52-03452-035 52-488
OUTSIDE SET53-468
358"
3" 114"
11332"
SILL HORIZONTALS
"A" DIM.=1 7/16" FOR 52-465 & 52-466 HORIZONTALS 1 9/16" FOR ALL OTHER HORIZONTALS
HORIZONTAL CLOSURE PLATE
114"
"A"
30°
INTERMEDIATE HORIZONTALS
1332
"
114"
358"
30°
INSIDE SET52-465 52-466
HEAD HORIZONTALS
15°
3364
"
114"
52-481
358"
30°
3" 114"
58"
53-46753-454 53-454 53-467
58"35
8"
53-45453-454
HORIZONTAL FACE
19-045
ADAPTORS IF REQUIRED19-183 52-001
53-000
52-016
HORIZONTAL RETAINER
11764"
58"
1332
"
11764"
58"
1332
"
EXP. VERT
EXP. VERT
EXP. VERTEXP. VERT
EXP. VERT
EXP. VERT
EXP. VERT
SLOT ASREQUIRED
SLOT ASREQUIRED
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F4FAB
3"
45°
1"
HORIZONTAL CLOSURE PLATE
1132"
1316"
5"
45°
41532"
41532"
45°
30°
358"
58"35
8"
45°
5"
1116" DIM.
FOR 52-488
1164"
SILL HORIZONTALS
45°
INTERIOR TRIMS & STOPS
52-035
*
52-034
*
53-454
52-488
53-4543"
53-000
HORIZONTAL FACE
19-045
ADAPTORS IF REQUIRED
HORIZONTAL RETAINER
1"
19-183
52-016
52-001
52-481
58"
1"30°
41532"
45°
OUTSIDE SET
REF. 45° & 22°30' ANGLE TAKEN FROM FACE OF INDIACTED WEB WALL
*
53-468
*
53-454
*
*
53-467
358"
* *
HEAD HORIZONTALS
52-466INSIDE SET
INTERMEDIATE HORIZONTALS
41532"
1332
"
53-454 53-467
*
* *
358"
11164"
1164"
1"
1"
30°
3364
"
30° 1"5
8"
1332
"58"
90°CORNER
1332
"
90°CORNER
90°CORNER
90°CORNER
90°CORNER
90°CORNER
90°CORNER
SLOT ASREQUIRED
SLOT ASREQUIRED
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F5FAB
INTERIOR TRIMS & STOPS
REF. 45° & 22°30' ANGLE TAKEN FROM FACE OF INDIACTED WEB WALL
12732"
52-03452-035
* *
52-488
*
45°
3364
"
**
45°
22°30' 22°30'
4964" DIM.
FOR 52-488
22°30'
78"
18"
INTERMEDIATE HORIZONTALS
2"
358"
SILL HORIZONTALS
18"7
8"
12732"
22°30'
45°18"
78"
3"
INSIDE SET52-465 52-466
2932"
5764"
78"
18"
116"
1316"
HORIZONTAL CLOSURE PLATE
78"
22°30'
1116"
52-481
HEAD HORIZONTALS
358"
78"
22°30'
45°
2" 3"
12732"
18"
12732"
*
53-45453-454 53-467
358"
* *
58"
53-467
*
OUTSIDE SET53-468
*
58"35
8"
53-454 53-454
* *
53-000
HORIZONTAL FACE52-016
HORIZONTAL RETAINER
ADAPTORS IF REQUIRED19-04519-183 52-001
58"
SLOT ASREQUIRED
SLOT ASREQUIRED
58"
135°CORNER
1332
"
135°CORNER
135°CORNER
135°CORNER
135°CORNER
135°CORNER
1332
"
1332
"
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F6FAB
FOR VERTICAL ABOVE VERTICAL EXPANSION JOINTVERTICAL LENGTH
FOR VERTICAL BELOW VERTICAL EXPANSION JOINT
VERTICAL LENGTH
VERTICAL RETAINERS
VERTICAL FACE
VERTICAL LENGTH
VERTICAL GLAZING POCKET ADAPTORS
VERTICAL LENGTH
VERTICAL LENGTH
VERTICAL LENGTH
VERTICAL GLAZING POCKET CLOSURE
19-045 & 19-183 SHOWN FOR RIGHT SIDEOF VERTICAL MULLION - LEFT SIDE OPPOSITE
"A" DIM. = 1 1/4" FOR OUTSIDE SET HORIZONTAL 1 3/16" FOR INSIDE SET HORIZONTAL
VERTICAL LENGTH
VERTICAL GLAZING POCKET ADAPTORS
VERTICAL GLAZING POCKET ADAPTORS
VERTICAL LENGTH
VERTICAL LENGTH
VERTICAL LENGTH
VERTICAL GLAZING POCKET CLOSURE
"A"
TOP OF VERT.AT EXP. JOINT
AT EXP. JOINTTOP OF VERT.
TOP OF VERT.AT EXP. JOINT
19-183
19-045
52-001
19-183
VERTICAL EXPANSION JOINTFOR VERTICAL BELOW
114"
114"
19-183
19-045
"A"
*
"A"
VERTICAL LENGTH
FOR VERTICAL IN MIDDLE OF WALL VERTICALLY
FOR VERTICAL AT TOP OF WALLVERTICAL LENGTH
AT EXP. JOINTBOTTOM OF VERT.
FOR VERTICAL AT BOTTOM OF WALL
VERTICAL LENGTH
VERTICAL LENGTH
VERTICAL LENGTH
VERTICAL LENGTH"A"
52-001
19-045
52-018
VERTICAL FACE
TOP OFHEAD HORIZ.
53-000
FOR VERTICAL ABOVEVERTICAL EXPANSION JOINT
52-001
SILL HORIZ.BOTTOM OF
53-014
53-000
TOP OF VERT.AT EXP. JOINT
114"
114"
AT EXP. JOINTBOTTOM OF VERT.
HORIZ. HORIZ. HORIZ.
HORIZ.
HORIZ.
HORIZ.
AT EXP. JOINTBOTTOM OF VERT.
HORIZ. (UPPER) HORIZ. (LOWER)
HORIZ. (UPPER) HORIZ. (LOWER)
HORIZ. (UPPER)
HORIZ. (UPPER)
AT EXP. JOINTBOTTOM OF VERT.
AT EXP. JOINTBOTTOM OF VERT.
(LOWER) HORIZ.
(LOWER) HORIZ.
VERTICAL RETAINERS
*
*
*
*
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F7FAB
VERTICAL LENGTH = (DLO + 138")
DLO
1/4" GLAZING ADAPTOR
HORIZONTAL LENGTH =(DLO + 0) -1/32"
1/4" GLAZING ADAPTOR
52-04211
4"
1116"
52-042
114"
53-500
RIGHT SIDE OF VERTICAL MULLIONS SHOWN
VERTICAL LENGTH
114"
LEFT SIDE APPLICATION OPPOSITE HAND
VERTICAL MULLIONS
114"
1116"
52-051
JAMB FILLER
53-50752-506 &
1116"
LENGTH
DIM.
218"
1116"
DIM.
LENGTH27
8"
1116"
114"
1"
114"
1116"
53-454FAB FOR
53-467OR
1116"
DIM.11
4"5/16"
53-454FAB FOR
114"
1116"
DIM.
FAB FOR
52-465SIMILAR
52-466
BOTT
OM
FAB FOR53-454 53-454
FAB FORFAB FOR53-468
BOTT
OM278"
1"
HORIZ. HORIZ.
VERT. VERT.
HORIZ. HORIZ. HORIZ.
HORIZ.HORIZ. HORIZ.
.201 DIA. (7 DRILL)
.201 DIA. (7 DRILL)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F8
VERTICAL LENGTH
90° OUTSIDE CORNER FACE
VERTICAL LENGTH
90° OUTSIDE CORNER FACE
ABOVE SPLICE JOINT
LENGTH=VERT. LENGTH+DIM.-1/4"
90° OUTSIDE CORNER FACE
VERTICAL LENGTH
LENGTH=VERT. LENGTH-DIM.-1/4"
VERTICAL LENGTH
90° OUTSIDE CORNER GUTTER
AT EXP. JOINTBOTTOM OF VERT.
112"
VERTICAL LENGTH
90° OUTSIDE CORNER GUTTER
VERTICAL LENGTH
90° OUTSIDE CORNER GUTTER
112"
52-040
52-040
52-040
AT EXP. JOINTTOP OF VERT.
52-046
52-046
52-046
OF
V
ER
T.
TO
P
14"
INTER. HORIZ.
DIM.
2732
"
VERTICAL LENGTH
135° OUTSIDE CORNER FACE
90° OUTSIDE CORNER135° OUTSIDE CORNER
52-022
52-542 52-542 52-540 52-540
14"
DIM.
BO
TT
OM
OF
V
ER
T.
1"
114"
1116"
278"
1"
114"
1116"
278"
FAB FOR
516"
DIM.
DIM.
LENGTH
218"
DIM.
LENGTH
DIM.
1116"
53-467
FAB FOR53-454
OR
1116"
114"
1116"
114"
1116"
52-466FAB FOR53-454
BOTT
OM
FAB FOR53-468
FAB FOR53-454
FAB FOR53-454
BOTT
OM
.201 DIA. (7 DRILL)
.201 DIA. (7 DRILL)
HORIZ. HORIZ. HORIZ.
HORIZ. HORIZ. HORIZ.
ABOVE SPLICE JOINT INTER. HORIZ.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
FABRICATION PROCEDURES
F9
114"
INTERIOR TRIMS & STOPS
52-03452-035 52-488
OUTSIDE SET53-468
114"
1932"
1716"
11764"
INTERMEDIATE HORIZONTALS
114" 3"
358"
58"
SILL HORIZONTALS
52-465INSIDE SET
52-466
11764"
HORIZONTAL CLOSURE PLATE
52-481
114"
114"
358"
58"
HEAD HORIZONTALS
3"
58"35
8"
53-46753-454 53-454 53-467
358"
58"
53-45453-454
52-001
ADAPTORS IF REQUIRED
52-016
19-045
HORIZONTAL FACE
19-183
HORIZONTAL RETAINER53-000
VERT.
VERT.VERT.
VERT. VERT.
VERT.
VERT.
SLOT ASREQUIRED
SLOT ASREQUIRED
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F10
3"
HORIZONTAL CLOSURE PLATE
358"
58"
SILL HORIZONTALS
11764"
52-034
INTERIOR TRIMS & STOPS
52-035 52-488
3" 114"
11332"
114"
1916"
52-481
114"
OUTSIDE SET53-468
HEAD HORIZONTALS
INSIDE SET
INTERMEDIATE HORIZONTALS
52-465 52-466
11764"
58"
114"
114"
358"
53-467
358"
53-4545
8"53-454 53-467
53-454
358"
58"
53-454
ADAPTORS IF REQUIRED
19-045
HORIZONTAL FACE
52-016
19-183 52-001
53-000
HORIZONTAL RETAINER
EXP. VERT
EXP. VERT
EXP. VERTEXP. VERT
EXP. VERT
EXP. VERT
EXP. VERT
SLOT ASREQUIRED
SLOT ASREQUIRED
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F11
INTERIOR TRIMS & STOPS
45°
52-03452-035 52-488
OUTSIDE SET53-468
45°
ADAPTORS IF REQUIRED
52-001
45°
732"
3132"
114"
52-035
52-488
52-034 19-183 19-045
INTERMEDIATE HORIZONTALS
45°
7"
358"
SILL HORIZONTALS
58"
58"
5"
INSIDE SET52-465 52-466
45°
22332"
45°
732"
732"
1932"
52-002
52-001
52-003
34"
45°
11132"
HORIZONTAL CLOSURE PLATE
52-481
2"
HEAD HORIZONTALS
358"
5"
45°
58"
7"
*
53-45453-454 53-467
358"
* *
58"
53-467
*
358"
58"
53-454 53-454
52-016
HORIZONTAL RETAINER
HORIZONTAL FACE
53-000
58"
58"
90°CORNER
90°CORNER
90°CORNER
90°CORNER
90°CORNER
90°CORNER
90° CORNEROUTSIDE
SLOT ASREQUIRED
SLOT ASREQUIRED
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F12
3"
1"
1516"
52-002
52-003
52-001
HORIZONTAL CLOSURE PLATE
5"
18°30'
358"
5"
34"
1"
1332"
SILL HORIZONTALS
18°30'
INTERIOR TRIMS & STOPS
52-035 52-034 52-488
52-034
52-035
52-488
3"
ADAPTORS IF REQUIRED
19-04519-183
1932"
34"
78"52-001
716"
52-481
716"
18°30'
OUTSIDE SET53-468
HEAD HORIZONTALS
INSIDE SET
INTERMEDIATE HORIZONTALS
52-465 52-46635
8"
18°30'
1764"
18°30'
18°30'
1332"
716"
52-466
52-465
716"
53-4545
8"53-454 53-467
358"
53-467
58"35
8"
53-454 53-454
HORIZONTAL RETAINER53-000
52-016
HORIZONTAL FACE
58"
58"
SLOT ASREQUIRED
SLOT ASREQUIRED
135°CORNER
135°CORNER
135°CORNER
135°CORNER
135°CORNER
135°CORNER
135° CORNEROUTSIDE
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F13
41732"
FACE OF INDIACTED WEB WALLREF. 45° & 22°30' ANGLE TAKEN FROM
AT 135° INSIDE CORNERHORIZONTAL RETAINER & FACES
HORIZONTAL RETAINER & FACES
45°
52-016
53-518
*
114"
53-518
732"
138"
34"
INTERMEDIATE VERTICAL & HORIZONTAL
52-019
22°30'
58"
114"
AT 90° INSIDE CORNER
52-016
53-000
45°
114"
138"
HORIZONTAL REGLAZE ADAPTOR
INTERMEDIATE HORIZONTAL
116"
1"53-518
*
22°30'
78"
532"
178"
53-000
*
90°CORNER
135°CORNER
MULLION
INSIDE90° CORNER
INSIDE135° CORNER
MULLION
EXP. VERT.
90° CORNER & VERT.135° CORNER
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 3 - Framing Fabrication
F14
SECTION 4 - SEALANT AND ERECTION PROCEDURES
In all the following details the perimeter sealant should be applied BEFORE THE FACE AND RETAINER ARE INSTALLED. However, the areabetween the outboard edge of the sill closure plate and the vertical retainer must be left open to allow water drainage.
When using 52-251 jambs preload exterior isolator gasket prior to installation.
Standard system splice joint including 2 sided SSG horizontals:Backer rod at vertical expansion joint should be approximately the same length as the metal splice and completely covered with sealant.(Refer to details 11, 12, 13 and 17.) When the vertical mullion has been properly located and anchored, apply a non-hardening,non-skinning sealant at the 1/2" nominal expansion joint to the entire front surface and return on each side approximately 1/2". Apply enoughsealant to front side of mullion to make a sealant reservoir so when mullion expands, sealant will not be overstretched. (Refer to details 14,15, 16 and 18.)
SSG 2 sided vertical, vertical splice joint:At the 1/2" vertical expansion joints this area must be sealed with a low modulus silicone compatible to the silicone used to structurally bondthe glass to the mullion. (Refer to details 31, 32 and 33.)
Anchorage of verticals at floor edge:Anchors should be arranged so that they always occur on the same side of the vertical mullions in the spandrel area, when glazing light fromthe interior. When this cannot be accomplished, glazing of this light may require the "re-glazing from exterior" procedure shown in details 9and 10 or the use of 52-265 horizontal. The glass edge spacer #12-908-6350 must be installed in the "deep" glazing pocket after the glassis set. These anti-walk spacers should be a minimum of two per light of glass spaced approximately 12" from top and bottom, and 3'-0" oncenter, maximum. For SSG verticals, interior corner lights cannot actually be set into the mullion from the interior of the building but must beset from the exterior even though they may be handled from the "floor". Of course the exterior weather seal must be installed from the exterior.Anti-walk spacers are not required on SSG verticals.
Glazing bead installation:For best watertight results, 17-004-6300 should be cut daylight opening plus 1/2". This will assure good tight joints at corners. Formaximum performance (8 P.S.F. water and higher), a bead of sealant should be placed in glazing bead pocket at each corner beforeinstalling 17-004-6300. Run sealant approximately 1-1/2" to 2" each way from corner. When installing 17-004-6300 be sure some sealantseals corners of 17-004-6300. Exterior glazing bead (12-514-6300) does not require this sealant.
Special SSG notes:On SSG mullions where "sealant" is in contact with the silicone sealant this "sealant" must be silicone compatible. Exterior horizontal facescrossing structural silicone verticals may be continuous across these verticals but must have an expansion joint at the expansion verticalwide enough to accommodate horizontal expansion. Of course when this is done the entire face will have to be removed during any exteriorre-glaze operations and is not recommended. When applying structural silicone to bond glass to mullion and weather seal silicone to sealbetween lights of glass, it is recommended that masking tape be applied either side of this silicone joint before applying silicone. Siliconemust be tooled into the joint and immediately after have tape removed before silicone begins to "Skin Over". Of course all glass and metaledges must be cleaned immediately before applying silicone as per silicone manufacturers' recommendations.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S1
17
18
4
ELEVATION
FLOOR PLAN
A COMPOSITE ELEVATION TO ILLUSTRATE TYPICAL CONDITIONS
14
1
INDICATES 1/4" INFILL
16
3
15
9
6
5
2
11
8
13 19 12
4
SILL
@
OPP.
1
SECTION
10
OPP.
7
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S2
FLOOR PLAN
SIM.
22
31
DETAILS NOTED REFER TO EFG DETAILS ONLY
31
26
FLOOR PLAN
A COMPOSITE ELEVATION TO ILLUSTRATE TYPICAL CONDITIONS
1
ELEVATION
25
*
1
14
7
10
*
INDICATES 1/4" INFILL
3
*
23
16
*
32
* *
*
11
9
10
13
*
OPP.
1
OPP.
7
28
*
SILL
@
25
ELEVATION
* *
21
*
*
*
28
33
30
SIM.
30
*
OPP.
1
SECTION
*
SIM.
29 29
*
*
24
*
27
OPP.
7
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S3
NOTE:
ISOLATOR GASKET PRIOR TO INSTALLATION OF FRAMING.WHEN USING 53-451 AT JAMB PRELOAD EXTERIOR
PERIMETER SEALANTWITH BACKER ROD
70-702-4160END CAP FIELD
3
END CAP FIELDINSTALLED
70-702-4160
SEALANT
INSTALLED
1
SEALANT
AS REQ'D
2A
END CAP FIELD70-702-4160
CONTINUOUS
VERTICAL/SILL INTERSECTION
2B
OF PERIMETER SEALANTINSTALLATION AND TOASSURE PROPER WEAPAGEOF SYSTEM AT BOTTOM
MITER BOTTOM OF VERTICALAS SHOWN TO ALLOW EASE
BOLTS IN GLASSPOCKET WITH SEALANT
HEADS OF ALL ANCHORCOMPLETELY COVER
WITH BACKER RODAS REQ'D
PERIMETER SEALANT
EXPANSION MULLION/
SILL INTERSECTION
COMPLETELY COVER
BOLTS IN GLASSHEADS OF ALL ANCHOR
POCKET WITH SEALANT
JAMB/SILL INTERSECTION
OF VERTICAL.
SEALANT
INSTALLED
2
INSTALLED
70-702-4160END CAP FIELD
SEALANT
WITH BACKER RODPERIMETER SEALANT
AS REQ'D
DOUBLE-FACE45
°
SECTION
SECTION
TAPE
2A
2B
IN ALL VERTICAL TO HORIZONTALINTERSECTIONS, SEALANT MUSTBE APPLIED SO AS TO FILLWEATHERSTRIP POCKET FLUSHWITH EXPOSED SURFACE.
53-451
NOTE:
2A
COMPLETELYCOVER HEADSOF ALL ANCHORBOLTS IN GLASSPOCKET WITHSEALANT
2B
53-454
52-481
NOTES:
1. All closure plates must be completely sealed to ends of verticalsand horizontals. This includes the glass dividing web of the verticalmullion across the front of the web. To aid this, the end cap must beset back 3/16" from the exterior plane of the glass.
2. In all these details, the perimeter sealant should be appliedBEFORE THE FACE AND RETAINER ARE INSTALLED. In any event thearea between the outboard edge of the sill closure plate and thevertical retainer must be left open to allow weepage.
3. On single height frames it is suggested that the mullion closureplate be installed at the top of the left frame and at the bottom of theright frame. This will allow the two frames to be snapped togetherslightly above each other, then slid together into proper alignment.Final sealing of these closure plates should be done after frames are inplace.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S4
90 DEG. OUTSIDE CORNER/SILL INTERSECTION
PERIMETER SEALANT
FIELD MODIFIED AS SHOWN,70-702-4160 END CAP
VERTICAL/INTERMEDIATE HORIZONTAL INTERSECTION
5
COMPLETELY FILL GLAZING
SEALANT AT VERTICAL &HORIZONTAL INTERSECTION
REGLET
70-702-4153WATER DEFLECTORFIELD INSTALLEDAFTER ASSEMBLY
10-379-4200TYPICAL
FIELD INSTALLED
4
WITH BACKER RODAS REQ'D
SEALANT ON BOTHSIDES OF VERT. WEB
COMPLETELY FILL BOLTCHASE WITH SEALANT
12-515-6300
DETAIL SHOWING EXPANSIONMULLION ENGAGEMENTEngage mullion halves by swinginghalf mullion out approximately 10degrees and snapping together as
Typical mullions are more easilysnapped together by engagingback edge first.
shown.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S5
VERTICAL/INTERMEDIATE HORIZONTAL TOP VIEW
5A
SEALANT AT VERTICAL & HORIZONTALINTERSECTION COMPLETELY FILL
GLAZING REGLET
1
53-450
52-481
53-468
CUT GASKETS D.L.O. + 14"PER FOOT OF D.L.O.
4
FILL GLAZING REGLET WITHSEALANT FOR 1" AT FRAME
JOINTS
5
PLACE DROP OF SEALANT ON GASKETEND
6
SEAL JOINT BETWEEN DEFLECTOR,HORIZONTAL AND VERTICAL FROM TOP
AND BOTTOM OF JOINT
3
DO NOT SEAL EXTERIOR EDGE OFDEFLECTOR
PRESS CENTER OF GASKET INTO HORIZONTALREGLET SO THAT ENDS OF GASKET SLIDE TO
BUTT VERTICAL GASKET - WIPE EXCESSSEALANT
7
1"
1"
CUT GASKETS D.L.O. + 14"PER FOOT OF D.L.O.
4
1. BEFORE APPLYING ANY SEALANT FOLLOW SEALANT MANUFACTURER'S INSTRUCTION FOR CLEANING / PRIMING. USE A GOOD GRADE SILICONE SEALANT AND COMPLETELYFILL THE GLAZING REGLET BETWEEN THE END OF THE HORIZONTAL AND THE VERTICAL FRAMING MEMBERS.
2. THE DEFLECTOR 70-702-4153 HAS AN ADHESIVE PAD. REMOVE THE LINING AND ADHERE THE DEFLECTOR TO THE UNDERSIDE OF THE HORIZONTAL GLAZING POCKET MAKINGSURE TO PLACE DEFLECTOR TIGHT TO INTERIOR SIDE OF FRAMING AND TIGHT TO BOTTOM OF VERTICAL GLAZING POCKET.
3. AFTER DEFLECTOR IS IN PLACE SEAL BETWEEN DEFLECTOR AND FRAMING MEMBERS. THE SEALANT IS INTENDED TO DIRECT ANY WATER IN THE HORIZONTAL GLAZINGPOCKET TO THE VERTICAL GLAZING POCKET WHERE IT WILL DRAIN OFF THE EXTERIOR MOST EDGE OF THE DEFLECTOR DOWN THE VERTICAL TO THE SILL. DO NOT SEAL THEEXTERIOR MOST EDGE OF THE DEFLECTOR.
4. THE GASKETS ARE TO BE CUT LONGER THAN THE DLO. IT IS RECOMMENDED THAT THE GASKET BE DLO PLUS ¼" FOR EACH FOOT OF DLO SIZE. SO FOR EXAMPLE A 4' DLOWOULD USE A GASKET 48" + (4) X ¼" OR 49" LONG.
5. BEFORE INSERTING GASKETS PREP CORNERS WITH A BEAD OF SEALANT IN THE GLAZING REGLETS FOR 1" BOTH VERTICALLY AND HORIZONTALLY FROM THE CORNER.6. INSTALL THE VERTICAL GASKETS . WHILE INSTALLING HORIZONTAL GASKETS INSERT ENDS OF GASKET INTO REGLETS A FEW INCHES FROM THE ENDS AND THEN APPLY A
SMALL BEAD OF SEALANT TO THE END OF THE GASKET.7. AS REMAINDER OF HORIZONTAL GASKET IS PRESSED INTO REGLET THE ENDS OF THE GASKET WILL SLIDE TIGHT TO THE VERTICAL GASKET. A GOOD APPLICATION OF
SEALANT WILL CREATE A SMALL SQUEEZE OUT OF SEALANT AT THE END WHICH CAN BE TOOLED FLUSH.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S6
VERTICAL/INTERMEDIATE HORIZONTAL BOTTOM VIEW
5B
SEAL JOINT BETWEEN DEFLECTOR,HORIZONTAL AND VERTICAL FROM TOP
AND BOTTOM OF JOINT
3
SEALANT AT VERTICAL & HORIZONTALINTERSECTION COMPLETELY FILL GLAZING
REGLET
1
FILL GLAZING REGLET WITHSEALANT FOR 1" AT FRAME
JOINTS
5
USE ADHSIVE PAD ON DEFLECTOR TO ADHEREDEFLECTOR TO HORIZONTAL
2
PRESS CENTER OF GASKET INTO HORIZONTALREGLET SO THAT ENDS OF GASKET SLIDE TO
BUTT VERTICAL GASKET - WIPE EXCESSSEALANT
7
CUT GASKETS D.L.O. + 14"PER FOOT OF D.L.O.
4
53-468
53-45052-481
CUT GASKETS D.L.O. + 14"PER FOOT OF D.L.O.
4
1"
1"
PLACE DROP OF SEALANT ON GASKETEND
6
DO NOT SEAL EXTERIOR EDGE OFDEFLECTOR
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S7
53-450
52-481
53-468
DO NOT SEAL JOINT BETWEEN VERTICALAND HORIZONTAL RETAINER
DO NOT SEAL BETWEENEXTERIOR GASKETS
VERTICAL/INTERMEDIATE HORIZONTAL TOP VIEW
5C
53-000
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S8
VERTICAL/INTERMEDIATE HORIZONTAL
INTERSECTION WITH GLAZING ADAPTORS
6
(INSIDE SET)
JAMB/HEAD INTERSECTION
7
PERIMETER SEALANT
JOINT AND MUST BE DONE ONTHIS SEALS THE METAL TO METALINSTALLING GLAZING ADAPTORS.GLAZING BEAD POCKET BEFORETAPE TO FACE OF MULLIONAPPLY 70-890-6300 SEALANT
FIELD INSTALLEDCLOSURE ANGLE72-944-4152
END CAP FIELD70-702-4160
SEALANT
INSTALLED
ALL ADAPTORS.
AS REQUIREDWITH BACKER ROD
OF GLAZING ADAPTOR.ADAPTOR. BE SURE TO SEAL TOPADAPTOR AGAINST VERTICALAT ENDS HORIZONTAL AROUNDHORIZONTAL INTERSECTION ALSOSEALANT AT VERTICAL &
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S9
TO REGLAZE FROM EXTERIOR Remove broken glass, glazing beads and faces.Cut off horizontal extrusion 52-266 as noted. Besure interior 17-004-6300 is properly installed andsealed at corners. Install new glass. Cut reglazeadaptor (52-019) daylight opening minus 3/8".Install 52-019 seal and reinstall exterior glazingbead (12-514-6300). Reinstall exterior faces.(Refer to details 9 & 10)
(REGLAZING FROM EXTERIOR - SHOWING GLASS BITE)
ANCHOR 3" FROM SIDE OF VERT.
SEALANT & BACKUP
52-035
PLACE (FROM INTERIOR)WEB AFTER HORIZONTAL IS INBOTTOM OF HORIZONTAL TOWEATHERSTRIP POCKET FROMAPPLY SEALANT IN VERTICAL
R.O.
FRAM
E SI
ZE
11 4"
2" 52-016
HORIZONTAL/INSIDE SET
53-000
10
C TO
C
D.L.
O.
634"
42332"
116"
58" 113
32"
(INSIDE SET)
VERTICAL/ INTERMEDIATE HORIZONTAL INTERSECTION
10-379-4200
PRESSURE OF GLAZING BEADSHELD IN PLACE BY BACK52-019 REGLAZE ADAPTOR ISFOR REGLAZING FROM EXTERIOR,BE CUT OFF AT "V" GROOVEHORIZONTAL EXTRUSION MUST
ON GLASS.
(FROM INTERIOR)TO INSTALLING ANY TRIMTO VERTICAL MULLION PRIORTO COMPLETELY SEAL 52-035APPLY A BEAD OF SEALANT
8
(FROM EXTERIOR)HORIZONTAL INTERSECTIONSEALANT AT VERTICAL &
(REGLAZING FROM EXTERIOR)
HORIZONTAL/INSIDE SET
21 2"
@ EACH END10-752-4200
72-944-4152
52-016
C TO
C
9
D.L.
O.D.
L.O.
C TO
C
634"
42332"5
8"
116"
11332"
53-46770-702-4160
52-466
70-881-6300
FIELD INSTALLEDWATER DEFLECTOR70-702-4153
52-035
(AS REQUIRED)
17-004-6300
12-514-6300
52-488
(AS REQUIRED)
52-034 @ VERT.
SEAL BACK SIDEOF 52-035 OR
JOINT
17-004-6300
12-514-6300
52-488
52-035
52-488TRIM COVER
1/4" glazing (52-034) to be sealedsimilar to 52-035.
NOTE:
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S10
BELOW, FIELD INSTALLEDSEALANT SIMILAR TO 1" GLAZINGAFTER SLIDING VERT. TOGETHERTO BOTTOM OF UPPER MULLION2 PCS. 16-775-4150 ATTACHED
14
JAMB SPLICE
(1" GLAZING)
AS REQUIREDWITH BACKER RODPERIMETER SEALANT
(1/4" GLAZING)
11
JAMB SPLICE
AS REQUIREDWITH BACKER RODPERIMETER SEALANT
FIELD INSTALLED
NON HARDENING
EXPANSION MULLION SPLICE
(1" GLAZING)
NON HARDENING
BURIED IN SEALANT
(1/4" GLAZING)
EXPANSION MULLION SPLICE
(1" GLAZING)
VERTICAL SPLICE
15
FIELD INSTALLED
NON HARDENING
FIELD INSTALLED
GUTTER SPLICE16-775-4150
NON SKINNING
SEALANT
SEALANT
FIELD INSTALL10-241-4200
16
SEALANT
NON SKINNING
FIELD INSTALL10-241-4200
VERTICAL SPLICE
(1/4" GLAZING)
53-470-4150SPLICE
12
NON HARDENING
BURIED IN SEALANT
SEALANT
NON SKINNING
53-471-4150SPLICE
13
SEALANT
NON SKINNING
OF PROPER SIZETO BE COMPLETELY
FIELD INSTALLED
TO BE COMPLETELYOF PROPER SIZE
FIELD INSTALLED
BACKER ROD
SPLICE53-470-4150
BACKER ROD
53-471-4150SPLICE
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S11
1"
FIELD INSTALLED
12-302-XX50
(1" GLAZING)
CORNER SPLICE
CORNER ASSEMBLY
(1/4" GLAZING)
CORNER SPLICE
BACKER ROD OFPROPER SIZE TOBE COMPLETELYBURIED IN SEALANT
20
17
1 2"
FACE SPLICE
19
AFTER ASSEM. 10-377-4200NEAR TOP & BOTTOM REMOVEATTACHING 52-009 ONE (1)BOLT USED AS HANDLE IN10-311-4200 TEMP. ASSEMBLY
52-472-4150
FIELD INSTALLED
10-241-4200FIELD INSTALLED
SEALANT
NON SKINNINGNON HARDENING
SPLICE
134"
SEALANTNON HARDENINGNON SKINNING
18
SEALANT FULL LENGTHFILL THIS VOID WITH
OF CORNER
278"
FIELD INSTALLEDMULLION SPLICE
FIELD INSTALLEDTEK SCREW10-241-XX00
TYPICAL SPLICE
334"
1 4"
FIELD INSTALLED
FIELD INSTALLED
SPLICEC MULLIONL
2"
10-241-4200
52-472-4150SPLICE
34"
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S12
53-468
53-500
EXPANSION VERTICAL SIMILAR
VERTICAL/INTERIOR SET HORIZONTAL
EXPANSION VERTICAL SIMILAR
VERTICAL/EXTERIOR SET HORIZONTAL
LEAVE 1/2" GAP12-514-6300
VERTICAL FOR WEEPAGEAT CENTER LINE OF
ERECTION BROCHURESSEALANT ANDTMW 453SHOWN INVERTICAL ASTO SIDE OFMUST BE SEALED52-486
22
21
VERTICAL FOR WEEPAGEAT CENTER LINE OFLEAVE 1/2" GAP12-514-6300
53-468
52-481
TO SIDE OF VERTICAL (ABOVE & BELOW
LINE OF VERTICAL. INSTALL BEFORE SETTING GLASS.SHELF OF EACH HORIZONTAL & BUTT TOGETHER AT CENTER52-050-4150 WATER DAM APPLY TO BOTTOM OF GLASS
MAYBE CONTINUOUS PAST VERTICAL OR12-514-6300 WEATHERSTRIP/ISOLATOR
BUTTED TIGHT AT CENTER LINE OF VERTICAL.
OF HORIZONTAL GLASS SHELF. THIS AREA MUST BE SEALED SOOF WATER DAMS & COMPLETELY SEAL TOP OF GLASS TO BOTTOM
THAT NO WATER CAN FLOW INTO ENDS OF HORIZONTAL. WEEPAGEMUST FLOW DOWN EXTERIOR OF VERTICAL 1/2" SILICONE JOINT.
1/2" SILICONE JOINT WEATHERSEAL MUST CONTINUE TO BOTTOM
COMPLETELY SEAL WATER DAMS TOHORIZONTALS & FRONT OF VERTICAL.
GLASS SHELF) IN GLASS POCKET AREA.
FILL ALL VOIDS
FROM EACH END OF RETAINERBY USING A 10-752-4200 FASTENER 3"RETAINERS TO BE SECURED TO HORIZONTALS
COMPLETELY SEAL END OF HORIZONTAL
TO SIDE OF VERTICAL IN GLASS
adaptor is installed.
When 53-518 horizontal is used with
1/4" glass in top light, setting block
shelf must be installed before 1/4"
MUST FLOW DOWN EXTERIOR OF VERTICAL 1/2" SILICONE JOINT.THAT NO WATER CAN FLOW INTO ENDS OF HORIZONTAL. WEEPAGEOF HORIZONTAL GLASS SHELF. THIS AREA MUST BE SEALED SOOF WATER DAMS & COMPLETELY SEAL TOP OF GLASS TO BOTTOM1/2" SILICONE JOINT WEATHERSEAL MUST CONTINUE TO BOTTOM
BUTTED TIGHT AT CENTER LINE OF VERTICAL.MAYBE CONTINUOUS PAST VERTICAL OR12-514-6300 WEATHERSTRIP/ISOLATOR
HORIZONTALS & FRONT OF VERTICAL.COMPLETELY SEAL WATER DAMS TO
EXPANSION VERTICAL SIMILAR
VERTICAL/SILICONE HORIZONTAL
HORIZONTAL & BUTT TOGETHER ATTO BOTTOM OF GLASS SHELF OF EACH70-702-4153 WATER DEFLECTOR APPLY
CENTER LINE OF VERTICAL
POCKET AREA. FILL ALL VOIDS
COMPLETELY SEAL HORIZONTAL
23
52-481
53-518
53-000
FILL ALL VOIDS
GLASS SHELF) IN GLASS POCKET AREA.TO SIDE OF VERTICAL (ABOVE & BELOWCOMPLETELY SEAL END OF HORIZONTAL
NOTE:
53-518
53-450
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S13
AT SILL - INSIDE SET:
SILL NOTE:
12-514-6300 weatherstrip/isolator may be continuouspast vertical or butted tight at center line of vertical (top& bottom).
12-514-6300 weatherstrip/isolator may be continuouspast vertical or butted tight at center line of vertical attop, at bottom leave a 1/2" gap in 12-514-6300 atcenter line of vertical.
52-000 retainer should be attached in place with a10-752-4200 screw at each end of retainer to preventretainer from being knocked off during installation ofglass.
fastener 3" from each end of retainer.
Retainers (53-000) to be secured to
horizontals by using a 10-752-4200
should seal to 12-514-6300 at head & seal.
Vertical weatherstrip joint between glass
EXPANSION VERTICAL SIMILAR
VERTICAL/SILL
VERTICAL RUNNING THRU
VERTICAL/INTERIOR SET HEAD
EXPANSION VERTICAL SIMILAR
BE REMOVED AND VOID SEALED WITH SILICONE.AT THE END OF THIS TIME THEY ARE TO BEIN PLACE WHILE STRUCTURAL SILICONE IS CURING.(TWIST IN PLACE) THESE TEMPORARIES MUST BE LEFT88-088-5100 TEMPORARY GLASS HOLDER 2'-0" OC.
(NOT BY PITTCO)WEATHERSEAL SILICONE
(NOT BY PITTCO)DENVER FOAM BACK-UP
GLASS IS IN PLACE.BY PITTCO) APPLY AFTERSTRUCTURAL SILICONE (NOT
12-916-6300 BACK-UP
TYPICAL VERTICAL SHOWING
INTERMEDIATE HORIZONTAL SIMILAR
EXPANSION VERTICAL SIMILAR
GLASS/SILICONE JOINT
WIDTH OF VERTICAL ISOF HORIZONTAL SO THATCAP APPLY TO BOTTOM70-702-4160 END
COVERED.
RETAINER NOTE:
53-000
26
53-454
52-481
HORIZONTAL RUNNING THRU
(STOPS ATOP
HOLE AT CENTER LINEDRILL 3/8" MINIMUM
53-454
HORIZONTAL)
OF VERTICAL FOR WEEPAGE
25
VERTICAL/SILL
HEAD NOTE:
53-518
HORIZONTAL FILL ALL VOIDSEND OF VERTICAL TOCOMPLETELY SEAL FRONT
12-514-6300
53-000
NOTE:
24
VERTICAL JOINT IN 53-000.OF VERTICAL ALSO SEALFILL ALL VOIDS AT FRONT
TO ENDS OF HORIZONTALSCOMPLETELY SEAL END CAP
53-000
12-514-6300
53-467
& FRONT OF VERTICAL.
52-481
53-500
VOIDS AT FRONT OF VERTICAL.FRONT OF VERTICAL. FILL ALLTO ENDS OF HORIZONTALS &COMPLETELY SEAL END CAP
TOP OF WEATHERSTRIP POCKETSIDE OF VERTICAL BEGINNING ATHORIZONTAL MUST BE SEALED TO
12-514-6300
AREA.
TO BOTTOM OF VERTICAL
VERTICAL IN GLASS POCKETBE SEALED TO SIDE OFLEG OF HORIZONTAL MUSTTHIS SMALL VERTICAL
ERECTION BROCHUREIN TMW 453 SEALANT &OF VERTICAL AS SHOWNMUST BE SEALED TO SIDE52-486 (SHOWN DOTTED)
THAT WIDTH OF VERTICAL ISTO TOP OF HORIZONTAL SO70-702-4160 END CAP APPLY
AS REQUIRED.
COVERED.
WITH BACKER RODPERIMETER SEALANT
52-481
2. All sealants that contact silicone sealants must be compatible.
1. All glass and metal must be clean and dry before applying any sealants.
NOTES:
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S14
SECURED TO HORIZONTALS BY
USING A 10-752-4200 FASTENER
3" FROM EACH END OF RETAINER
SECURED TO HORIZONTALS BY
USING A 10-752-4200 FASTENER
3" FROM EACH END OF RETAINER
SILICONE WEATHERSTRIP JOINT
CENTER LINE OF 1/2" VERTICAL
DRILL 3/8" MINIMUM HOLE AT
STOP SHORT OF WEEP HOLE.
BOTTOM 12-514-6300 MUST
52-046
BOTTOM OF WEATHERSTRIP POCKET
GLASS POCKET, BEGINNING AT
SEALED TO SIDE OF CORNER IN
HORIZONTAL MUST BE COMPLETELY
AREA. FILL ALL VOIDS AT END
OF CORNER IN GLASS POCKET
ENDS OF HORIZONTAL AND END
COMPLETELY SEAL END CAP TO
CORNER IS COVERED AS SHOWN.
HORIZONTAL SO THAT END OF
MITER AND APPLY TO TOP OF
70-702-4160 END CAP FIELD
RETAINERS (53-000) TO BE
PERIMETER SEALANT.
FOR WEEPAGE
END OF 52-046 WITH
53-000 RETAINER
DO NOT COMPLETELY PLUG
CORNER AND BUTT TIGHT.
WEATHERSTRIP/ISOLATOR AT
MITER TOP 12-514-6300
TO TOP OF HORIZONTAL.
OF CORNERS.
RETAINERS (53-000) TO BE
CORNER IS COVERED AS SHOWN.
70-702-4160 END CAP FIELD
MITER AND APPLY TO BOTTOM OF
HORIZONTAL SO THAT END OF
90 DEG. CORNER/SILL HORIZONTAL
90 DEG. CORNER/HEAD HORIZONTAL
135 DEG. CORNER SIMILAR
28
135 DEG. CORNER SIMILAR
52-040
27
52-540
GLASS POCKET, BEGINNING AT
TOP OF WEATHERSTRIP POCKET
53-454
52-481
TO BOTTOM OF HORIZONTAL.
HORIZONTAL MUST BE COMPLETELY
SEALED TO SIDE OF CORNER IN
COMPLETELY SEAL END CAP TO
ENDS OF HORIZONTAL AND END
OF CORNER IN GLASS POCKET
AREA. FILL ALL VOIDS AT END
OF CORNERS.
PERIMETER SEALANTWITH BACKER RODAS REQUIRED.
52-481
53-454
can not be interior set.90 deg. & 135 deg. outside silicone cornersNOTE:
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S15
STOP BOTTOM 12-514-6300
BUTT TIGHT TO SIDE OF 52-046APPLY TO BOTTOM OF GLASS SHELF.70-702-4153 WATER DEFLECTOR
90 DEG. CORNER/52-466 HORIZONTAL
90 DEG. CORNER/EXTERIOR SET HORIZONTAL
USING A 10-752-4200 FASTENER3" FROM EACH END OF RETAINER
CORNER, FILL ALL VOIDS.
AGAINST 52-046SHELF AND BUTT TIGHTAPPLY TO BOTTOM OF GLASS52-050-4150 WATER DAM
TO HORIZONTAL AND FRONT OFCOMPLETELY SEAL WATER DAM
CORNER AND BUTT TIGHT.WEATHERSTRIP/ISOLATOR ATMITER TOP 12-514-6300
RETAINERS (53-000) TO BESECURED TO HORIZONTALS BY
135 DEG. CORNER SIMILAR
30
135 DEG. CORNER SIMILAR
29
AT END OF HORIZONTAL
FRONT OF CORNER, FILL ALL VOIDS.
MITER TOP 12-514-6300
TO END OF HORIZONTAL ANDCOMPLETELY SEAL WATER DAM
CORNER AND BUTT TIGHT.WEATHERSTRIP/ISOLATOR AT
RETAINER53-000
52-540
AT END OF HORIZONTALSTOP BOTTOM 12-514-6300
52-488
52-035
52-019
52-466
53-468
POCKET, INCLUDING THESE POCKETS.CONTINUE TO BOTTOM WEATHERSTRIPAT TOP WEATHERSTRIP POCKET &IN GLASS POCKET AREA. BEGIN(ABOVE & BELOW GLASS SHELF)HORIZONTAL TO SIDE OF CORNERCOMPLETELY SEAL END OF
NOTE:
1/2" vertical silicone joint weatherseal mustcontinue to bottom of water deflector andcompletely seal top of glass to bottom ofhorizontal shelf. Same as at typical vertical.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S16
DENVER FOAM ROD STOCK BEFORESTUFF ENDS OF "ADAPTOR" WITH
EXPANSION VERTICAL MULLION
EXPANSION JOINT 1" GLASS
TYPICAL VERTICAL MULLION
32
1" INSULATED GLASS
STRUCTURAL SILICONE
52-506
31
1" INSULATED GLASS
1" GLASS JOINT.)SILICONE SEALANT. (SIMILAR TOFILLING EXPANSION JOINT WITH
EXPANSION JOINT
1" GLASS
52-481
STRUCTURAL SILICONE
EXPANSION JOINT 1" GLASS
90 DEG. OUTSIDE CORNER
GLASS TO MULLIONS).AS USED TO BONDSEALANT (SAME SILICONESTRUCTURAL SILICONEJOINT VOIDS WITHFILL ALL EXPANSION
52-040, FILL ALL VOIDS.WITH SILICONE AT SPLICE IN53-500 & 52-009 AND FILLSTUFF VOIDS BETWEEN 52-040,
33
TO BOND GLASS TO MULLION).SEALANT (SAME SILICONE AS USEDVOIDS WITH STRUCTURAL SILICONEFILL ALL SPLICE (EXPANSION) JOINT
52-540
MULLION SPLICE)DIRECTLY ABOVE CORNERLINE OF HORIZONTAL FACEJOINT TO OCCUR AT CENTER52-046 (CORNER FACE SPLICE
SPACER GASKETSTOP AT EXPANSION
53-521-4150
12-916-6300
SPLICE
VERTICALEXPANSIONJOINT
JOINT
53-507
1/4" GLASS
EXPANSION JOINT
SPACER GASKET
OCCUR 1 1/2" MIN.
52-040 VERTICAL
HEADS IN THISSEAL ALL BOLT
MULLION SPLICE
AREA.
JOINT.
BELOW CORNER
SPLICE JOINT TO
52-040 SPLICELOCATION ASSTOPS AT SAME
JOINT.
1" INSULATED
12-916-6300
SILICONESTRUCTURAL
GLASS
VERTICALEXPANSIONJOINT
(SAME SILICONE AS USED TO BONDWITH STRUCTURAL SILICONE SEALANTFILL ALL EXPANSION JOINT VOIDS
12-916-6300 SPACER GASKET
GLASS TO MULLIONS).
JOINTEXPANSIONVERTICAL
53-520-4150 SPLICE
STOP AT EXPANSION JOINT
53-500
VERTICALEXPANSIONJOINT
(SPLICE JOINT)
52-540
SPLICE52-522-4150
MULLION LOCK52-009 CORNER
Horizontal should occur within
36" of splice joint shown below.
JOINT
VERTICALEXPANSION
NOTE:
Also a continuous bead of sealant must be applied between
135 deg. outside corner similar except 52-022 outside trimhas splice joint at same location as 52-542 mullion.
52-542 halves.
NOTE:
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 4 - Sealant and Erection
S17
of sealant as requiredApply small bead
FINAL POSITION
1 7/8"POCKET
GLASS
CONTACT
"W" SIDE BLOCKS
19-1
83
19-0
45
FIG. 2
SLIDE BETWEEN REGLETFLATTEN BLOCK &
AND GLASS LITE.
STRETCH
INSERT BETWEENGLASS & FRAME.
work towards centerStart at ends and
Horizontal Gasket
Gasket = Approximately
runs through
D.L.O. + 1/2"
FIG. 1*Notes:1. Glazing Adaptors 19-045 & 19-183 are provided for applicationsrequiring infills less than 1" in thickness (See Glazing Chart). Theseadaptors are designed to be inserted into the reglet, and they must beinserted after installation of frame so sealing procedures can beaccomplished at joint.
2. Horizontal to vertical joints of adaptors should be sealed afterinstallation.
One "W" Side Block (12-908-6350 or 12-908-6351)should be installed into the deep pocket of the mullion ofeach light of glass to prevent shifting of the glass in theopening. (See FIG. 2)
NOTE: If deglazing of lite is required after "W" Block is installed, remove both interior and exterior weathering and use hook to pull "W" Block out of the pocket.
"W" Block (12-908-6350 or 12-908-6351) will expandand wedge between walls of glazing pocket and preventglass from shifting into deep pocket.
12-908-6350or
12-908-6351
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
SECTION 5 - Glazing
G1
TMW GlazingGlass
ThicknessExteriorGasket
InteriorGlasket
PocketAdaptor
1/8" 12-522 17-012 19-0453/16" 12-514 17-012 19-0451/4" 12-514 17-004 19-0455/16" 12-514 17-013 19-0453/8" 12-521 17-013 19-0451/2" 12-522 17-012 19-1839/16" 12-514 17-012 19-1835/8" 12-514 17-004 19-183
11/16" 12-514 17-013 19-1833/4" 12-521 17-013 19-1837/8" 12-522 17-012 None
15/16" 12-514 17-012 None1' 12-514 17-004 None
1 1/16" 12-514 17-013 None1 1/8" 12-521 17-013 None
System designed for maximum 1 1/8" glazing
GLASS SIZE FORMULA
Daylight Opening
Daylight Opening + 1"
12" 1
2"
Dayl
ight
Ope
ning
Dayl
ight
Ope
ning
+ 1
"
1 2"1 2"
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMW 453
JUNE 2019
TMW 453
JUNE 2019
SECTION 5 - Glazing