TIMELY OPERATED ELECTRICAL APPLIANCE CONTROL SYSTEM Abstract: The aim of this project is to save electricity by the timely control of electronic appliance s ,this is helpful is the places where no one is there to control manually switch to on and off the device. For example street lights, lights at parks ECT. The proposed system consists of a microcontroller interfaced with a RTC, the user sets the time and microcontroller reads time from the RTC, when the TIME is equal the microcontroller on or off the device based on the program control.

Transcript of Time Operated Electrical Appliance Control System

Page 1: Time Operated Electrical Appliance Control System

TIMELY OPERATED ELECTRICAL APPLIANCE CONTROL SYSTEM

Abstract:

The aim of this project is to save electricity by the timely control of electronic appliance s ,this is helpful is the places where no one is there to control manually switch to on and off the device. For example street lights, lights at parks ECT.

The proposed system consists of a microcontroller interfaced with a RTC, the user sets the time and microcontroller reads time from the RTC, when the TIME is equal the microcontroller on or off the device based on the program control.

Page 2: Time Operated Electrical Appliance Control System

BLOCK DIAGRAM:

ULN2003

RELAYS

KEYPAD

MEMORY

RELAYS

LCD

RELAYS

RELAYS

8051

RELAYS

RTC

Page 3: Time Operated Electrical Appliance Control System

Modules in Block diagram:

1. Microcontroller(P89v51rd2)2. RTC3. Memory4. Keypad5. ULN20036. Relay

Page 4: Time Operated Electrical Appliance Control System

Block Diagram Explanation:

1. Microcontroller:

Micro Controller (P89V51RD2):

The P89V51RD2 is 80C51 microcontrollers with 64kB Flash and 1024

bytes of data RAM.

A key feature of the P89V51RD2 is its X2 mode option. The design engineer can

choose to run the application with the conventional 80C51 clock rate (12 clocks per

machine cycle) or select the X2 mode (6 clocks per machine cycle) to achieve twice the

throughput at the same clock frequency. Another way to benefit from this feature is to keep

the same performance by reducing the clock frequency by half, thus dramatically reducing

the EMI.

The Flash program memory supports both parallel programming and in

serial In-System Programming (ISP). Parallel programming mode offers gang-

programming at high speed, reducing programming costs and time to market.

ISP allows a device to be reprogrammed in the end product under software

control. The capability to field/update the application firmware makes a wide

range of applications possible.

The P89V51RD2 is also In-Application Programmable (IAP), allowing

the Flash program memory to be reconfigured even while the application is

running.

Features:

Page 5: Time Operated Electrical Appliance Control System

80C51 Central Processing Unit

5 V Operating voltage from 0 MHz to 40 MHz

16/32/64 kB of on-chip Flash user code memory with ISP

(In-System

Programming) and IAP (In-Application Programming)

Supports 12-clock (default) or 6-clock mode selection via

software or ISP

SPI (Serial Peripheral Interface) and enhanced UART

PCA (Programmable Counter Array) with PWM and

Capture/Compare functions

Four 8-bit I/O ports with three high-current Port 1 pins (16

mA each)

Three 16-bit timers/counters

Programmable watchdog timer

Eight interrupt sources with four priority levels

Second DPTR register

Low EMI mode (ALE inhibit)

TTL- and CMOS-compatible logic levels

Brown-out detection

Low power modes

1. Power-down mode with external interrupt wake-up

2. Idle mode

PDIP40, PLCC44 and TQFP44 packages

Block diagram

Page 6: Time Operated Electrical Appliance Control System

Pin Configuration:

Page 7: Time Operated Electrical Appliance Control System

Pin description

Page 8: Time Operated Electrical Appliance Control System
Page 9: Time Operated Electrical Appliance Control System
Page 10: Time Operated Electrical Appliance Control System
Page 11: Time Operated Electrical Appliance Control System

Functional Description:

Power-On reset code execution

Following reset, the P89V51RD2 will either enter the Soft ICE

mode (if previously enabled via ISP command) or attempt to auto

baud to the ISP boot loader. If this auto baud is not successful within

about 400 ms, the device will begin execution of the user code.

In-System Programming (ISP)

In-System Programming is performed without removing the

microcontroller from the system. The In-System Programming

facility consists of a series of internal hardware resources coupled

with internal firmware to facilitate remote programming of the

P89V51RD2 through the serial port. This firmware is provided by

Philips and embedded within each P89V51RD2 device. The Philips

In-System Programming facility has made in-circuit programming in

an embedded application possible with a minimum of additional

expense in components and circuit board area. The ISP function uses

five pins (VDD, VSS, TxD, RxD, and RST). Only a small connector

needs to be available to interface your application to an external

circuit in order to use this feature.

Input/output (I/O) ports

Page 12: Time Operated Electrical Appliance Control System

32 of the pins are arranged as four 8-bit I/O ports P0–P3.

Twenty-four of these pins are dual purpose with each capable of

operating as a control line or part of the data/address bus in

addition to the I/O functions. Details are as follows:

Port 0 This is a dual-purpose port occupying pins 32 to 39 of the

device. The port is an open-drain bidirectional I/O port with Schmitt

trigger inputs. Pins that have 1s written to them float and can be

used as high-impedance inputs. The port may be used with external

memory to provide a multiplexed address and data bus. In this

application internal pull-ups are used when emitting 1s. The port

also outputs the code bytes during EPROM programming. External

pull-ups are necessary during program verification.

Port 1 This is a dedicated I/O port occupying pins 1 to 8 of the

device. The pins are connected via internal pull-ups and Schmitt

trigger input. Pins that have 1s written to them are pulled high by

the internal pull-ups and can be used as inputs; as inputs, pins that

are externally pulled low will source current via the internal pull-

ups. The port also receives the low-order address byte during

program memory verification. Pins P1.0 and P1.1 could also function

as external inputs for the third timer/counter i.e.:

(P1.0) T2 Timer/counter 2 external count input/clockout

Page 13: Time Operated Electrical Appliance Control System

(P1.1) T2EX Timer/counter 2 reload/capture/direction control

Port 2 This is a dual-purpose port occupying pins 21 to 28 of the

device. The specification is similar to that of port 1. The port may be

used to provide the high-order byte of the address bus for external

program memory or external data memory that uses 16-bit

addresses. When accessing external data memory that uses 8-bit

addresses, the port emits the contents of the P2 register. Some port

2 pins receive the high-order address bits during EPROM

programming and verification.

Port 3 This is a dual-purpose port occupying pins 10 to 17 of the

device. The specification is similar to that of port 1. These pins, in

addition to the I/O role, serve the special features of the 80C51

family; the alternate functions are summarized below:

P3.0 RxD serial data input port

P3.1 TxD serial data output port

P3.2 INT0 external interrupt 0

P3.3 INT1 external interrupt 1

P3.4 T0 timer/counter 0 external input

P3.5 T1 timer/counter 1 external input

P3.6 WR external data memory writes strobe

Page 14: Time Operated Electrical Appliance Control System

P3.7 RD external data memory read strobe.

Timers/counters 0 and 1

The two 16-bit Timer/Counter registers: Timer 0 and Timer 1

can be configured to

operate either as timers or event counters (see Table 12 and Table

13). In the ‘Timer’ function, the register is incremented every

machine cycle. Thus, one can think of it as counting machine cycles.

Since a machine cycle consists of six oscillator periods, the count

rate is 1¤6 of the oscillator frequency. In the ‘Counter’ function, the

register is incremented in response to a 1-to-0 transition at its

corresponding external input pin, T0 or T1. In this function, the

external input is sampled once every machine cycle.

When the samples show a high in one cycle and a low in the next

cycle, the count is incremented. The new count value appears in the

register in the machine cycle following the one in which the

transition was detected. Since it takes two machine cycles (12

oscillator periods) for 1-to-0 transition to be recognized, the

maximum count rate is 1¤12 of the oscillator frequency. There are

no restrictions on the duty cycle of the external input signal, but to

ensure that a given level is sampled at least once before it changes, it

should be held for at least one full machine cycle. In addition to the

Page 15: Time Operated Electrical Appliance Control System

‘Timer’ or ‘Counter’ selection, Timer 0 and Timer 1 have four

operating modes from which to select.

The ‘Timer’ or ‘Counter’ function is selected by control bits C/T in

the Special Function Register TMOD. These two Timer/Counters

have four operating modes, which are selected by bit-pairs (M1, M0)

in TMOD. Modes 0, 1, and 2 are the same for both Timers/Counters.

Mode 3 is different. The four operating modes are described in the

following text.

TMOD - Timer/Counter mode control register (address 89H) bit

allocation

Not bit addressable; Reset value: 00000000B; Reset source(s): any

source

TMOD - Timer/Counter mode control register (address 89H) bit

description

Page 16: Time Operated Electrical Appliance Control System

TMOD - Timer/Counter mode control register (address 89H) M1/M0 operating mode

TCON - Timer/Counter control register (address 88H) bit

allocation

Page 17: Time Operated Electrical Appliance Control System

Bit addressable; Reset value: 00000000B; Reset source(s): any reset

TCON - Timer/Counter control register (address 88H) bit

description

Page 18: Time Operated Electrical Appliance Control System

Mode 0

Putting either Timer into Mode 0 makes it look like an 8048

Timer, which is an 8-bit Counter with a fixed divide-by-32 prescaler.

Figure 7 shows Mode 0 operation.

Page 19: Time Operated Electrical Appliance Control System

In this mode, the Timer register is configured as a 13-bit register. As the

count rolls over from all 1s to all 0s, it sets the Timer interrupt flag TFn. The

count input is enabled to the Timer when TRn = 1 and either GATE = 0 or INTn

= 1. (Setting GATE = 1 allows the Timer to be controlled by external input

INTn, to facilitate pulse width measurements). TRn is a control bit in the

Special Function Register TCON (Figure 6). The GATE bit is in the TMOD

register.

The 13-bit register consists of all 8 bits of THn and the lower 5 bits of TLn. The

upper 3 bits of TLn are indeterminate and should be ignored. Setting the run

flag (TRn) does not clear the registers. Mode 0 operation is the same for Timer

0 and Timer 1 (see Figure 7). There are two

different GATE bits, one for Timer 1 (TMOD.7) and one for Timer 0 (TMOD.3).

Mode 1

Page 20: Time Operated Electrical Appliance Control System

Mode 1 is the same as Mode 0, except that all 16 bits of the timer register

(THn and TLn) are used. See Figure 8.

Mode 2

Mode 2 configures the Timer register as an 8-bit Counter (TLn)

with automatic reload, as shown in Figure 9. Overflow from TLn not

only sets TFn, but also reloads TLn with the contents of THn, which

must be preset by software. The reload leaves THn unchanged.

Mode 2 operation is the same for Timer 0 and Timer 1.

Page 21: Time Operated Electrical Appliance Control System

Mode 3

When timer 1 is in Mode 3 it is stopped (holds its count). The effect

is the same as setting TR1 = 0. Timer 0 in Mode 3 establishes TL0

and TH0 as two separate 8-bit counters. The logic for Mode 3 and

Timer 0 is shown in Figure 10. TL0 uses the Timer 0 control bits:

T0C/T, T0GATE, TR0, INT0, and TF0. TH0 is locked into a timer

function (counting machine cycles) and takes over the use of TR1

and TF1 from Timer 1. Thus, TH0 now controls the ‘Timer 1’

interrupt. Mode 3 is provided for applications that require an extra

8-bit timer. With Timer 0 in Mode 3, the P89V51RD2 can look like it

has an additional Timer.

Note: When Timer 0 is in Mode 3, Timer 1 can be turned on and off

by switching it into and out of its own Mode 3. It can still be used by

the serial port as a baud rate generator, or in any application not

requiring an interrupt.

Page 22: Time Operated Electrical Appliance Control System

Timer 2

Timer 2 is a 16-bit Timer/Counter which can operate as either an

event timer or an event counter, as selected by C/T2 in the special

function register T2CON. Timer 2 has four operating modes:

Capture, Auto-reload (up or down counting), Clock-out, and Baud

Rate Generator which are selected according to Table 17 using

T2CON (Table 18 and Table 19) and T2MOD (Table 20 and Table

21).

Timer 2 operating mode

Page 23: Time Operated Electrical Appliance Control System

T2CON - Timer/Counter 2 control register (address C8H) bit

allocation

Page 24: Time Operated Electrical Appliance Control System

T2CON - Timer/Counter 2 control register (address C8H) bit description

Page 25: Time Operated Electrical Appliance Control System

T2MOD - Timer 2 mode control register (address C9H)

bit allocation

Page 26: Time Operated Electrical Appliance Control System

T2MOD - Timer 2 mode control register (address C9H)

bit description

Capture mode

In the Capture Mode there are two options which are selected

by bit EXEN2 in T2CON. If EXEN2 = 0 Timer 2 is a 16-bit timer or

counter (as selected by C/T2 in T2CON) which upon overflowing

sets bit TF2, the Timer 2 overflow bit.

The capture mode is illustrated in Figure 11.

Page 27: Time Operated Electrical Appliance Control System

This bit can be used to generate an interrupt (by enabling the

Timer 2 interrupt bit in the IEN0 register). If EXEN2 = 1, Timer 2

operates as described above, but with the added feature that a 1- to -

0 transition at external input T2EX causes the current value in the

Timer 2 registers, TL2 and TH2, to be captured into registers

RCAP2L and RCAP2H, respectively. In addition, the transition at

T2EX causes bit EXF2 in T2CON to be set, and EXF2 like TF2 can

generate an interrupt (which vectors to the same location as Timer

2 overflow interrupt). The Timer 2 interrupt service routine can

interrogate TF2 and EXF2 to determine which event caused the

interrupt. There is no reload value for TL2 and TH2 in this mode.

Even when a capture event occurs from T2EX, the counter keeps on

counting T2 pin transitions or fosc/6 pulses. Since once loaded

contents of RCAP2L and RCAP2H registers are not protected, once

Timer2 interrupt is signalled it has to be serviced before new

capture event on T2EX pin occurs. Otherwise, the next falling edge

Page 28: Time Operated Electrical Appliance Control System

on T2EX pin will initiate reload of the current value from TL2 and

TH2 to RCAP2L and RCAP2H and consequently corrupt their content

related to previously reported interrupt.

Auto-reload mode (up or down counter)

In the 16-bit auto-reload mode, Timer 2 can be configured as

either a timer or counter (via C/T2 in T2CON), then programmed to

count up or down. The counting direction is determined by bit DCEN

(Down Counter Enable) which is located in the T2MOD register (see

Table 20 and Table 21). When reset is applied, DCEN = 0 and Timer

2 will default to counting up. If the DCEN bit is set, Timer 2 can

count up or down depending on the value of the T2EX pin.

Figure 12 shows Timer 2 counting up automatically (DCEN =

0).

Page 29: Time Operated Electrical Appliance Control System

In this mode, there are two options selected by bit EXEN2 in

T2CON register. If EXEN2 = 0, then Timer 2 counts up to 0FFFFH

and sets the TF2 (Overflow Flag) bit upon overflow. This causes the

Timer 2 registers to be reloaded with the 16-bit value in RCAP2L

and RCAP2H. The values in RCAP2L and RCAP2H are preset by

software means.

Auto reload frequency when Timer 2 is counting up can be

determined from this

formula:

Where Supply Frequency is either fosc (C/T2 = 0) or frequency

of signal on T2 pin (C/T2 = 1). If EXEN2 = 1, a 16-bit reload can be

triggered either by an overflow or by a 1-to-0 transition at input

T2EX. This transition also sets the EXF2 bit. The Timer 2 interrupt, if

enabled, can be generated when either TF2 or EXF2 is ‘1’.

Microcontroller’s hardware will need three consecutive machine

cycles in order to recognize falling edge on T2EX and set EXF2 = 1:

in the first machine cycle pin T2EX has to be sampled as ‘1’; in the

second machine cycle it has to be sampled as ‘0’, and in the third

machine cycle EXF2 will be set to ‘1’.

Page 30: Time Operated Electrical Appliance Control System

In Figure 13, DCEN = 1 and Timer 2 is enabled to count up or

down. This mode allows pin T2EX to control the direction of count.

When a logic ‘1’ is applied at pin T2EX Timer 2 will count up. Timer

2 will overflow at 0FFFFH and set the TF2 flag, which can then

generate an interrupt, if the interrupt is enabled. This timer

overflow also causes the 16-bit value in RCAP2L and RCAP2H to be

reloaded into the timer registers TL2 and TH2.

When a logic 0 is applied at pin T2EX this causes Timer 2 to

count down. The timer will underflow when TL2 and TH2 become

equal to the value stored in RCAP2L and RCAP2H. Timer 2

underflow sets the TF2 flag and causes 0FFFFH to be reloaded into

the timer registers TL2 and TH2. The external flag EXF2 toggles

when Timer 2 underflows or overflows. This EXF2 bit can be used as

a 17th bit of resolution if needed.

Page 31: Time Operated Electrical Appliance Control System

Baud rate generator mode

Bits TCLK and/or RCLK in T2CON allow the UART) transmit

and receive baud rates to be derived from either Timer 1 or Timer 2

(See Section 7.5 “UARTs” on page 35 for details). When TCLK = 0,

Timer 1 is used as the UART transmit baud rate generator. When

TCLK = 1, Timer 2 is used as the UART transmit baud rate generator.

RCLK has the same effect for the UART receive baud rate. With these

two bits, the serial port can have different receive and transmit baud

rates – Timer 1 or Timer 2. Figure 14 shows Timer 2 in baud rate

generator mode:

The baud rate generation mode is like the auto-reload mode,

when a rollover in TH2 causes the Timer 2 registers to be reloaded

with the 16-bit value in registers RCAP2H and RCAP2L, which are

preset by software. The baud rates in modes 1 and 3 are determined

by Timer 2’s overflow rate given below:

Page 32: Time Operated Electrical Appliance Control System

Modes 1 and 3 Baud Rates = Timer 2 Overflow Rate/16

The timer can be configured for either ‘timer’ or ‘counter’

operation. In many applications, it is configured for ‘timer' operation

(C/T2 = 0). Timer operation is different for Timer 2 when it is being

used as a baud rate generator. Usually, as a timer it would increment

every machine cycle (i.e., 1¤6 the oscillator frequency). As a baud

rate generator, it increments at the oscillator frequency. Thus the

baud rate formula is as follows:

Modes 1 and 3 Baud Rates =

Where: (RCAP2H, RCAP2L) = The content of RCAP2H and RCAP2L

taken as a 16-bit unsigned integer. The Timer 2 as a baud rate

generator mode is valid only if RCLK and/or TCLK = 1 in T2CON

register. Note that a rollover in TH2 does not set TF2, and will not

generate an interrupt. Thus, the Timer 2 interrupt does not have to

be disabled when Timer 2 is in the baud rate generator mode. Also if

the EXEN2 (T2 external enable flag) is set, a 1-to-0 transition in

T2EX (Timer/counter 2 trigger input) will set EXF2 (T2 external

flag) but will not cause a reload from (RCAP2H, RCAP2L) to

(TH2,TL2). Therefore when Timer 2 is in use as a baud rate

generator, T2EX can be used as an additional external interrupt, if

Page 33: Time Operated Electrical Appliance Control System

needed. When Timer 2 is in the baud rate generator mode, one

should not try to read or write TH2 and TL2. Under these

conditions, a read or write of TH2 or TL2 may not be accurate. The

RCAP2 registers may be read, but should not be written to, because

a write might overlap a reload and cause write and/or reload errors.

The timer should be turned off (clear TR2) before accessing the

Timer 2 or RCAP2 registers. Table 22 shows commonly used baud

rates and how they can be obtained from Timer 2.

Summary of baud rate equations

Timer 2 is in baud rate generating mode. If Timer 2 is being

clocked through pin T2(P1.0) the baud rate is:

Baud rate = Timer 2 overflow rate / 16

If Timer 2 is being clocked internally, the baud rate is:

Baud rate = fosc / (16 ´ (65536 - (RCAP2H, RCAP2L)))

Where fosc = oscillator frequency

To obtain the reload value for RCAP2H and RCAP2L, the above

equation can be

rewritten as:

RCAP2H, RCAP2L = 65536 - fosc / (16 ´ baud rate)

Page 34: Time Operated Electrical Appliance Control System

Table 22: Timer 2 generated commonly used baud rates

UART

The UART operates in all standard modes. Enhancements over

the standard 80C51 UART include Framing Error detection, and

automatic address recognition.

Mode 0

Serial data enters and exits through RxD and TxD outputs

the shift clock. Only 8 bits are transmitted or received, LSB

first. The baud rate is fixed at 1¤6 of the CPU clock frequency.

UART configured to operate in this mode outputs serial clock

on TxD line no matter whether it sends or receives data on RxD

line.

Page 35: Time Operated Electrical Appliance Control System

Mode 1

10 bits are transmitted (through TxD) or received

(through RxD): a start bit (logical 0), 8 data bits (LSB first), and

a stop bit (logical 1). When data is received, the stop bit is

stored in RB8 in Special Function Register SCON. The baud rate

is variable and is determined by the Timer 1¤2 overflow rate.

Mode 2

11 bits are transmitted (through TxD) or received

(through RxD): start bit (logical 0), 8 data bits (LSB first), a

programmable 9th data bit, and a stop bit (logical 1). When

data is transmitted, the 9th data bit (TB8 in SCON) can be

assigned the value of 0 or (e.g. the parity bit (P, in the PSW)

could be moved into TB8). When data is received, the 9th data

bit goes into RB8 in Special Function Register SCON, while the

stop bit is ignored. The baud rate is programmable to either

1¤16 or 1¤32 of the CPU clock frequency, as determined by the

SMOD1 bit in PCON.

Mode 3

11 bits are transmitted (through TxD) or received

(through RxD): a start bit (logical 0), 8 data bits (LSB first), a

programmable 9th data bit, and a stop bit (logical 1). In fact,

Page 36: Time Operated Electrical Appliance Control System

Mode 3 is the same as Mode 2 in all respects except baud rate.

The baud rate in Mode 3 is variable and is determined by the

Timer 1/2 overflow rate.

Table 23: SCON - Serial port control register (address 98H)

bit allocation

Table 24: SCON - Serial port control register (address 98H)

bit description

Page 37: Time Operated Electrical Appliance Control System

Table 25: SCON - Serial port control register (address 98H)

SM0/SM1 mode definition

Page 38: Time Operated Electrical Appliance Control System

Framing error

Framing error (FE) is reported in the SCON.7 bit if SMOD0

(PCON.6) = 1. If SMOD0 = 0, SCON.7 is the SM0 bit for the UART, it is

recommended that SM0 is set up before SMOD0 is set to ‘1’.

More about UART mode 1

Reception is initiated by a detected 1-to-0 transition at RxD.

For this purpose RxD is sampled at a rate of 16 times whatever baud

rate has been established. When a transition is detected, the divide-

by-16 counter is immediately reset to align its rollovers with the

boundaries of the incoming bit times.

The 16 states of the counter divide each bit time into 16ths. At

the 7th, 8th, and 9th counter states of each bit time, the bit detector

samples the value of RxD. The value accepted is the value that was

seen in at least 2 of the 3 samples. This is done for noise rejection. If

the value accepted during the first bit time is not 0, the receive

circuits are reset and the unit goes back to looking for another 1-to-

0 transition. This is to provide rejection of false start bits. If the start

bit proves valid, it is shifted into the input shift register, and

reception of the rest of the frame will proceed. The signal to load

SBUF and RB8, and to set RI, will be generated if, and only if, the

following conditions are met at the time the final shift pulse is

Page 39: Time Operated Electrical Appliance Control System

generated: (a) RI = 0, and (b) Either SM2 = 0, or the received stop bit

= 1. If either of these two conditions is not met, the received frame is

irretrievably lost. If both conditions are met, the stop bit goes into

RB8, the 8 data bits go into SBUF, and RI is activated.

More about UART modes 2 and 3

Reception is performed in the same manner as in mode 1. The

signal to load SBUF and RB8, and to set RI, will be generated if, and

only if, the following conditions are met at the time the final shift

pulse is generated: (a) RI = 0, and (b) Either SM2 = 0, or the received

9th data bit = 1. If either of these conditions is not met, the received

frame is irretrievably lost, and RI is not set. If both conditions are

met, the received 9th data bit goes into RB8, and the first 8 data bits

go into SBUF.

Multiprocessor communications

UART modes 2 and 3 have a special provision for

multiprocessor communications. In these modes, 9 data bits are

received or transmitted. When data is received, the 9th bit is stored

in RB8. The UART can be programmed so that when the stop bit is

received, the serial port interrupt will be activated only if RB8 = 1.

This feature is enabled by setting bit SM2 in SCON. One way to use

this feature in multiprocessor systems is as follows:

Page 40: Time Operated Electrical Appliance Control System

When the master processor wants to transmit a block of data

to one of several slaves, it first sends out an address byte which

identifies the target slave. An address byte differs from a data byte

in a way that the 9th bit is ‘1’ in an address byte and ‘0’ in the data

byte. With SM2 = 1, no slave will be interrupted by a data byte, i.e.

the received 9th bit is ‘0’. However, an address byte having the 9th

bit set to ‘1’ will interrupt all slaves, so that each slave can examine

the received byte and see if it is being addressed or not. The

addressed slave will clear its SM2 bit and prepare to receive the data

(still 9 bits long) that follow. The slaves that weren’t being

addressed leave their SM2 bits set and go on about their business,

ignoring the subsequent data bytes.

SM2 has no effect in Mode 0, and in Mode 1 can be used to

check the validity of the stop bit, although this is better done with

the Framing Error flag. When UART receives data in mode 1 and

SM2 = 1, the receive interrupt will not be activated unless a valid

stop bit is received.

Page 41: Time Operated Electrical Appliance Control System

2. RTC (DS1307):

FEATURES Real-time clock (RTC) counts seconds, minutes, hours, date of the

month, month, day of the week, and year with leap-year compensation valid up to 2100

56-byte, battery-backed, nonvolatile (NV) RAM for data storage Two-wire serial interface Programmable square wave output signal Automatic power-fail detect and switch circuitry Consumes less than 500nA in battery backup mode with oscillator

running Optional industrial temperature range: -40°C to +85°C Available in 8-pin DIP or SOIC Underwriters Laboratory (UL) recognized

PIN ASSIGNMENT

PIN DESCRIPTIONVCC - Primary Power SupplyX1, X2 - 32.768kHz Crystal ConnectionVBAT - +3V Battery InputGND - GroundSDA - Serial DataSCL - Serial ClockSQW/OUT - Square Wave/Output Driver

Page 42: Time Operated Electrical Appliance Control System

DESCRIPTIONThe DS1307 Serial Real-Time Clock is a low-power; full binary-coded decimal (BCD) clock/calendar plus 56 bytes of NV SRAM. Address and data are transferred serially via a 2-wire, bi-directional bus.The clock/calendar provides seconds, minutes, hours, day, date, month, and year information. The end of the month date is automatically adjusted for months with fewer than 31 days, including corrections for leap year. The clock operates in either the 24-hour or 12-hour format with AM/PM indicator. The DS1307 has a built-in power sense circuit that detects power failures and automatically switches to the battery supply.

TYPICAL OPERATING CIRCUIT

OPERATIONThe DS1307 operates as a slave device on the serial bus. Access is obtained by implementing a START condition and providing a device identification code followed by a register address. Subsequent registers can be accessed sequentially until a STOP condition is executed. When VCC falls below 1.25 x VBAT the device terminates an access in progress and resets the device address counter. Inputs to the device will not be recognized at this time to prevent erroneous data from being written to the device from an out of

Page 43: Time Operated Electrical Appliance Control System

tolerance system. When VCC falls below VBAT the device switches into a low-current battery backup mode. Upon power-up, the device switches from battery to VCC when VCC is greater than VBAT + 0.2V and recognizes inputs when VCC is greater than 1.25 x VBAT. The block diagram in Figure 1 shows the main elements of the serial RTC.

DS1307 BLOCK DIAGRAM Figure 1

SIGNAL DESCRIPTIONS

Page 44: Time Operated Electrical Appliance Control System

VCC, GND – DC power is provided to the device on these pins. VCC is the +5V input. When 5V is applied within normal limits, the device is fully accessible and data can be written and read. When a 3V battery is connected to the device and VCC is below 1.25 x VBAT, reads and writes are inhibited. However, the timekeeping function continues unaffected by the lower input voltage. As VCC falls below VBAT the RAM and timekeeper are switched over to the external power supply (nominal 3.0V DC) at VBAT.VBAT – Battery input for any standard 3V lithium cell or other energy source. Battery voltage must be held between 2.0V and 3.5V for proper operation. The nominal write protect trip point voltage at which access to the RTC and user RAM is denied is set by the internal circuitry as 1.25 x VBAT nominal. A lithium battery with 48mAhr or greater will back up the DS1307 for more than 10 years in the absence of power at 25ºC. UL recognized to ensure against reverse charging current when used in conjunction with a lithium battery.See “Conditions of Acceptability” at http://www.maxim-ic.com/TechSupport/QA/ntrl.htm.SCL (Serial Clock Input) – SCL is used to synchronize data movement on the serial interface.SDA (Serial Data Input/Output) – SDA is the input/output pin for the 2-wire serial interface. The SDA pin is open drain which requires an external pullup resistor.SQW/OUT (Square Wave/Output Driver) – When enabled, the SQWE bit set to 1, the SQW/OUT pin outputs one of four square wave frequencies (1Hz, 4kHz, 8kHz, 32kHz). The SQW/OUT pin is open drain and requires an external pull-up resistor. SQW/OUT will operate with either Vcc or Vbat applied.X1, X2 – Connections for a standard 32.768kHz quartz crystal. The internal oscillator circuitry isdesigned for operation with a crystal having a specified load capacitance (CL) of 12.5pF.For more information on crystal selection and crystal layout considerations, please consult ApplicationNote 58, “Crystal Considerations with Dallas Real-Time Clocks.” The DS1307 can also be driven by anexternal 32.768kHz oscillator. In this configuration, the X1 pin is connected to the external oscillatorsignal and the X2 pin is floated.RECOMMENDED LAYOUT FOR CRYSTAL

Page 45: Time Operated Electrical Appliance Control System

CLOCK ACCURACYThe accuracy of the clock is dependent upon the accuracy of the crystal and the accuracy of the match between the capacitive load of the oscillator circuit and the capacitive load for which the crystal was trimmed. Additional error will be added by crystal frequency drift caused by temperature shifts. External circuit noise coupled into the oscillator circuit may result in the clock running fast. See Application Note 58, “Crystal Considerations with Dallas Real-Time Clocks” for detailed information.Please review Application Note 95, “Interfacing the DS1307 with a 8051-Compatible Microcontroller” for additional information.RTC AND RAM ADDRESS MAPThe address map for the RTC and RAM registers of the DS1307 is shown in Figure 2. The RTC registers are located in address locations 00h to 07h. The RAM registers are located in address locations 08h to 3Fh. During a multi-byte access, when the address pointer reaches 3Fh, the end of RAM space, it wraps around to location 00h, the beginning of the clock space.DS1307 ADDRESS MAP Figure 2

Page 46: Time Operated Electrical Appliance Control System

CLOCK AND CALENDARThe time and calendar information is obtained by reading the appropriate register bytes. The RTC registers are illustrated in Figure 3. The time and calendar are set or initialized by writing the appropriate register bytes. The contents of the time and calendar registers are in the BCD format. Bit 7 of register 0 is the clock halt (CH) bit. When this bit is set to a 1, the oscillator is disabled. When cleared to a 0, the oscillator is enabled.Please note that the initial power-on state of all registers is not defined. Therefore, it is importantto enable the oscillator (CH bit = 0) during initial configuration.The DS1307 can be run in either 12-hour or 24-hour mode. Bit 6 of the hours register is defined as the 12- or 24-hour mode select bit. When high, the 12-hour mode is selected. In the 12-hour mode, bit 5 is the AM/PM bit with logic high being PM. In the 24-hour mode, bit 5 is the second 10 hour bit (20-23 hours).On a 2-wire START, the current time is transferred to a second set of registers. The time information is read from these secondary registers, while the clock may continue to run. This eliminates the need to reread the registers in case of an update of the main registers during a read.DS1307 TIMEKEEPER REGISTERS Figure 3

Page 47: Time Operated Electrical Appliance Control System

CONTROL REGISTERThe DS1307 control register is used to control the operation of the SQW/OUT pin.

OUT (Output control): This bit controls the output level of the SQW/OUT pin when the square wave output is disabled. If SQWE = 0, the logic level on the SQW/OUT pin is 1 if OUT = 1 and is 0 if OUT = 0.SQWE (Square Wave Enable): This bit, when set to a logic 1, will enable the oscillator output. The frequency of the square wave output depends upon the value of the RS0 and RS1 bits. With the square wave output set to 1Hz, the clock registers update on the falling edge of the square wave.RS (Rate Select): These bits control the frequency of the square wave output when the square wave output has been enabled. Table 1 lists the square wave frequencies that can be selected with the RS bits.SQUAREWAVE OUTPUT FREQUENCY Table 1

2-WIRE SERIAL DATA BUSThe DS1307 supports a bi-directional, 2-wire bus and data transmission protocol. A device that sends data onto the bus is defined as a transmitter and

Page 48: Time Operated Electrical Appliance Control System

a device receiving data as a receiver. The device that controls the message is called a master. The devices that are controlled by the master are referred to as slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions. The DS1307 operates as a slave on the 2-wire bus. A typical bus configuration using this 2-wire protocol is show in Figure 4.TYPICAL 2-WIRE BUS CONFIGURATION Figure 4

Figures 5, 6, and 7 detail how data is transferred on the 2-wire bus._ Data transfer may be initiated only when the bus is not busy._ During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in the data line while the clock line is high will be interpreted as control signals.Accordingly, the following bus conditions have been defined:Bus not busy: Both data and clock lines remain HIGH.Start data transfer: A change in the state of the data line, from HIGH to LOW, while the clock is HIGH, defines a START condition.Stop data transfer: A change in the state of the data line, from LOW to HIGH, while the clock line is HIGH, defines the STOP condition.Data valid: The state of the data line represents valid data when, after a START condition, the data line is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed during the LOW period of the clock signal. There is one clock pulse per bit of data.Each data transfer is initiated with a START condition and terminated with a STOP condition. The number of data bytes transferred between START and STOP conditions is not limited, and is determined by the master device. The information is transferred byte-wise and each receiver acknowledges with a

Page 49: Time Operated Electrical Appliance Control System

ninth bit. Within the 2-wire bus specifications a regular mode (100 kHz clock rate) and a fast mode (400 kHz clock rate) are defined. The DS1307 operates in the regular mode (100 kHz) only.Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the reception of each byte. The master device must generate an extra clock pulse which is associated with this acknowledge bit. A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is stable LOW during the HIGH period of the acknowledge related clock pulse. Of course, setup and hold times must be taken into account. A master must signal an end of data to the slave by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this case, the slave must leave the data line HIGH to enable the master to generate the STOP condition.

DATA TRANSFER ON 2-WIRE SERIAL BUS Figure 5

Depending upon the state of the R/W bit, two types of data transfer are possible:1. Data transfer from a master transmitter to a slave receiver. The first byte transmitted by the master is the slave address. Next follows a number of

Page 50: Time Operated Electrical Appliance Control System

data bytes. The slave returns an acknowledge bit after each received byte. Data is transferred with the most significant bit (MSB) first.2. Data transfer from a slave transmitter to a master receiver. The first byte (the slave address) is transmitted by the master. The slave then returns an acknowledge bit. This is followed by the slave transmitting a number of data bytes. The master returns an acknowledge bit after all received bytes other than the last byte. At the end of the last received byte, a “not acknowledge” is returned. The master device generates all of the serial clock pulses and the START and STOP conditions. A transfer is ended with a STOP condition or with a repeated START condition. Since a repeated START condition is also the beginning of the next serial transfer, the bus will not be released. Data is transferred with the most significant bit (MSB) first.The DS1307 may operate in the following two modes:1. Slave receiver mode (DS1307 write mode): Serial data and clock are received through SDA and SCL. After each byte is received an acknowledge bit is transmitted. START and STOP conditionsare recognized as the beginning and end of a serial transfer. Address recognition is performed by hardware after reception of the slave address and *direction bit (See Figure 6). The address byte is the first byte received after the start condition is generated by the master. The address byte contains the 7 bit DS1307 address, which is 1101000, followed by the *direction bit (R/W ) which, for a write, is a 0. After receiving and decoding the address byte the device outputs an acknowledge on the SDA line. After the DS1307 acknowledges the slave address + write bit, the master transmits a register address to the DS1307 this will set the register pointer on the DS1307. The master will then begin transmitting each byte of data with the DS1307 acknowledging each byte received. The master will generate a stop condition to terminate the data write.DATA WRITE – SLAVE RECEIVER MODE Figure 6

2. Slave transmitter mode (DS1307 read mode): The first byte is received and handled as in the slave receiver mode. However, in this mode, the *direction bit will indicate that the transfer direction is reversed. Serial data is transmitted on SDA by the DS1307 while the serial clock is input on SCL.

Page 51: Time Operated Electrical Appliance Control System

START and STOP conditions are recognized as the beginning and end of a serial transfer (See Figure 7). The address byte is the first byte received after the start condition is generated by the master. The address byte contains the 7-bit DS1307 address, which is 1101000, followed by the*direction bit (R/W ) which, for a read, is a 1. After receiving and decoding the address byte the device inputs an acknowledge on the SDA line. The DS1307 then begins to transmit data starting with the register address pointed to by the register pointer. If the register pointer is not written tobefore the initiation of a read mode the first address that is read is the last one stored in the register pointer. The DS1307 must receive a “not acknowledge” to end a read.DATA READ – SLAVE TRANSMITTER MODE Figure 7

Page 52: Time Operated Electrical Appliance Control System

3. Memory:

FEATURES• Low power CMOS technology• Hardware write protect• Two wire serial interface bus, I2C compatible• 5.0V only operation• Self-timed write cycle (including auto-erase)• Page-write buffer• 1ms write cycle time for single byte• 1,000,000 Erase/Write cycles guaranteed• Data retention >200 years• 8-pin DIP/SOIC packages• Available for extended temperature ranges- Commercial (C): 0°C to +70°C- Industrial (I): -40°C to +85°C- Automotive (E): --40°C to +125°C

DESCRIPTIONThe Microchip Technology Inc. 24C01A/02A/04A is a 1K/2K/4K bit Electrically Erasable PROM. The device is organized as shown, with a standard two wire serial interface. Advanced CMOS technology allows a significant reduction in power over NMOS serial devices. Aspecial feature in the 24C02A and 24C04A provides hardware write protection for the upper half of the block. The 24C01A and 24C02A have a page write capability of two bytes and the 24C04A has a page length of eight bytes. Up to eight 24C01A or 24C02A devices and upto four 24C04A devices may be connected to the same two wire bus.This device offers fast (1ms) byte write and extended (-40°C to 125°C) temperature operation. It is recommended that all other applications useMicrochip’s 24LCXXB.

Page 53: Time Operated Electrical Appliance Control System

4. Keypad:

Here we have used a normal 4x3 matrix key pad. Which

can be used to give input of numbers from 0 to 9, * and #.

5. ULN2003

The eight NPN Darlington connected transistors in this family of

arrays are ideally suited for interfacing between low logic level

digital circuitry (such as TTL, CMOS or PMOS/NMOS) and the higher

current/voltage requirements of lamps, relays, printer hammers or

other similar loads for a broad range of computer, industrial, and

consumer applications. All devices feature open–collector outputs

and freewheeling clamp diodes for transient suppression.

MAXIMUM RATINGS (TA = 25°C and rating apply to any one device

in the package, unless otherwise noted.)

Page 54: Time Operated Electrical Appliance Control System
Page 55: Time Operated Electrical Appliance Control System

TEST FIGURES

(See Figure Numbers in Electrical Characteristics Table)

Page 56: Time Operated Electrical Appliance Control System
Page 57: Time Operated Electrical Appliance Control System
Page 58: Time Operated Electrical Appliance Control System
Page 59: Time Operated Electrical Appliance Control System

TYPICAL CHARACTERISTIC CURVES – TA = 25°C, unless otherwise

noted

Output Characteristics

Page 60: Time Operated Electrical Appliance Control System
Page 61: Time Operated Electrical Appliance Control System

Input Characteristics

Page 62: Time Operated Electrical Appliance Control System

Figure 12. Representative Schematic Diagrams

Page 63: Time Operated Electrical Appliance Control System

6. Relay:

Page 64: Time Operated Electrical Appliance Control System

Here we are using relay as switch. to make device ON and

OFF automatically

/*********************************************************

Source code for the project

----------------------------

Main program

*********************************************************/

//

********************************************************************

*************************/

// PROJECT NAME : TIMELY OPERATED ELECTRICAL APPLIANCE

CONTROL SYSTEM

// MODULE NAME : MAIN

// FILE NAME : MAIN.C

// ABSTRACT : THIS FILE IMPLEMENTS A DEVICE FOR

P89V51RD2 TO DEVOLOP A SYSTEM WHICH WILL

// TIMELY OPERATE THE ELECTRICAL APPLIANCE

CONNECTED TO THE DEVICE

Page 65: Time Operated Electrical Appliance Control System

// COMPILER : KEIL 3

// AUTHOR : V.V.GUPTA FOR AKSHARA TECHNOLOGIES

// Date : 13 APR 2009

//REVISED DATE :

// WARNING:THIS FILE HAS BEEN AUTOMATICALLY

GENERATE.DO NOT EDIT THIS FILE IF U

// INTEND TO REGENERATE IT .

//

********************************************************************

**************************/

//

====================================================]

// Include Librarry Files

//

====================================================]

#include <reg51F.H>

#include"rtc.c"

#include"kb2p.h"

Page 66: Time Operated Electrical Appliance Control System

#include"lcd.C"

#include"i2c.C"

sbit relay = P3^5;

sbit reset= P3^4;

sbit Watch_dog_refresh =WDTC^1;

sbit Watch_dog_status=WDTC^2;

unsigned char hour=0x12, min=0x59, sec=0x00;

void iitoa(unsigned char a)

{

int c1,c2;

c2=a;

c1=a&0x0f;

c1=c1|0x30;

c2=c2>>4;

Page 67: Time Operated Electrical Appliance Control System

c2=c2|0x30;

LCD_DATA_WRT(c2);

LCD_DATA_WRT(c1);

}

void m_delay()

{

long int a;

for (a=0;a<4400;a++);

}

void s_delay()

{

long int a;

for (a=0;a<9999;a++);

Page 68: Time Operated Electrical Appliance Control System

}

void delay()

{

long i;

for(i=0;i<99999;i++);

}

unsigned char ch,ch_h,ch_m,ch_s, h_l,h_m,key,

al_hr_on[10],al_min_on[10], al_hr_off,al_min_off;

int index;

int j=0;

/

********************************************************************

***********************

main starts here

Page 69: Time Operated Electrical Appliance Control System

********************************************************************

***********************/

main()

{

int k,s=0,q,m=0;

P2 =0xFF;

IE=0x85;

EX1=1; //Enable external interrupt 1

EX0=1; //Enable external interrupt 0

EA=1; //Global interrupt enable

LCD_INIT();

PRINTLCD("Akshara Technologies");

s_delay();

Page 70: Time Operated Electrical Appliance Control System

s_delay();

LCD_CMD_WRT(0x01);

while(1)

{

LCD_CMD_WRT(0x0C);

LCD_CMD_WRT(0x85);

ch_h= R_ReadBYTE(0x02);

iitoa(ch_h);

LCD_DATA_WRT(':');

//send_char(':');

ch_m= R_ReadBYTE(0x01);

iitoa(ch_m);

//send_char(':');

LCD_DATA_WRT(':');

ch_s= R_ReadBYTE(0x00);

q = R_ReadBYTE(0x03);

Page 71: Time Operated Electrical Appliance Control System

iitoa(ch_s);

for(k=0;k<=10;k++)

{

al_hr_on[k] = ReadBYTE(0x00+(0x10*k));

al_min_on[k] = ReadBYTE(0x08+(0x10*k));

if(ch_h == al_hr_on[k] && ch_m == al_min_on[k] && ch_s == 0x00 &&

q!=0x01)

{

relay=0;

break;

}

else if(ch_h == al_hr_on[k] && ch_m == al_min_on[k] && ch_s ==

0x03 && q!=0x01)

{

relay=1;

break;

}

Page 72: Time Operated Electrical Appliance Control System

}

s_delay();

m_delay();

//if(Watch_dog_status == 1)

//{

//WDTC =0x00;

//Watch_dog_status = 1;

//}

//send_string("\n\r");

}

}

Page 73: Time Operated Electrical Appliance Control System

void current_time(void) interrupt 0

{

unsigned char day, d_m,d_l, month, m_m,m_l, year, y_l,y_m;

LCD_CMD_WRT(0x01);

PRINTLCD(" Enter Time");

LCD_CMD_WRT(0xC5);

//LCD_CMD_WRT(0x01);

PRINTLCD("hh:mm ");

LCD_CMD_WRT(0xC5);

//getting hour from the user

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

h_m = key&0x0f;

Page 74: Time Operated Electrical Appliance Control System

h_m = h_m<<0x04;

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

h_l = key&0x0f;

hour= h_m|h_l;

LCD_CMD_WRT(0xC8);

// getting mins from the user

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

h_m = key&0x0f;

h_m = h_m<<0x04;

key = scan_key();

LCD_DATA_WRT(key);

Page 75: Time Operated Electrical Appliance Control System

s_delay();

h_l = key&0x0f;

min= h_m|h_l;

R_WriteBYTE(0x00,sec);

R_WriteBYTE(0x01,min);

R_WriteBYTE(0x02,hour);

LCD_CMD_WRT(0x01);

PRINTLCD(" Enter DATE");

LCD_CMD_WRT(0xC5);

PRINTLCD("DD/MM/YY");

LCD_CMD_WRT(0xC5);

Page 76: Time Operated Electrical Appliance Control System

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

d_m = key&0x0f;

d_m = d_m<<0x04;

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

d_l = key&0x0f;

day = d_m|d_l;

LCD_CMD_WRT(0xC8);

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

m_m = key&0x0f;

m_m = m_m<<0x04;

Page 77: Time Operated Electrical Appliance Control System

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

m_l = key&0x0f;

month = m_m|m_l;

LCD_CMD_WRT(0xCB);

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

y_m = key&0x0f;

y_m = y_m<<0x04;

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

y_l = key&0x0f;

year = y_m|y_l;

Page 78: Time Operated Electrical Appliance Control System

LCD_CMD_WRT(0x01);

R_WriteBYTE(0x04,day);

R_WriteBYTE(0x05,month);

R_WriteBYTE(0x06,year);

PRINTLCD(" Enter DAY");

LCD_CMD_WRT(0xC5);

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

d_m = key&0x0f;

d_m = d_m<<0x04;

key = scan_key();

Page 79: Time Operated Electrical Appliance Control System

LCD_DATA_WRT(key);

s_delay();

d_l = key&0x0f;

day = d_m|d_l;

R_WriteBYTE(0x03,day);

LCD_CMD_WRT(0x01);

}

void set_schedule(void) interrupt 2

{

unsigned char ch,f=1;

{

while(1)

{

LCD_CMD_WRT(0x01);

PRINTLCD("1: ADD ON time ");

Page 80: Time Operated Electrical Appliance Control System

LCD_CMD_WRT(0xC0);

PRINTLCD("2: EXIT ");

ch=scan_key();

if (ch == '1')

{

LCD_CMD_WRT(0x01);

PRINTLCD(" enter ON time");

LCD_CMD_WRT(0xC5);

PRINTLCD("hh:mm ");

LCD_CMD_WRT(0xC5);

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

h_m = key&0x0f;

h_m = h_m<<0x04;

Page 81: Time Operated Electrical Appliance Control System

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

h_l = key&0x0f;

al_hr_on[j]= h_m|h_l;

WriteBYTE((0x00+(0x10*j)),al_hr_on[j]);

LCD_CMD_WRT(0xC8);

key = scan_key();

LCD_DATA_WRT(key);

s_delay();

h_m = key&0x0f;

h_m = h_m<<0x04;

key =scan_key();

LCD_DATA_WRT(key);

Page 82: Time Operated Electrical Appliance Control System

s_delay();

h_l = key&0x0f;

al_min_on[j]= h_m|h_l;

WriteBYTE((0x08+(0x10*j)),al_min_on[j]);

++j;

LCD_CMD_WRT(0x01);

}

else if (ch == '2')

{

LCD_CMD_WRT(0x01);

index=j;

break;

}

}

}

Page 83: Time Operated Electrical Appliance Control System

}