TIA Portal V14 SP1 Technical slides
Transcript of TIA Portal V14 SP1 Technical slides
TIA Portal V14 SP1 Technical slides
Unrestricted © Siemens AG 2017
Unrestricted © Siemens AG 2017
TIA updater: Fast mass update
Openness: Ex/Import HW +IO via AutomationML
ProDiag: Criteria analysis for S7-Graph
Safety: Consistent Hardware- and Software Upload
Option handling with S7-1500F
F-IO-Status function block
6. TIA Portal options 2. STEP 7 - Innovations
Freely editable comments for array and UDT
New instructions
Single block comparison
User comments visible directly in the code
New technology object for SIMATIC Ident
3. WinCC - Innovations 5. System functions
Integration of SINUMERIK Operate in Runtime Advanced
OPC UA DA client for WinCC Runtime Professional
WinCC WebUX- Auto Login for WinCC RT Professional
1. Hardware configuration
Support for new hardware components
- CPU1511T(F) / CPU1515T(F)
- Power Supply 60W 24/48/60V DC HF
New functions for the operability
TIA Portal
Highlights of TIA Portal V14 SP1
March 2017 Page 2
Details
Optimized and extended
commissioning wizard
Online/offline comparison of parameter
values
4. Startdrive - Innovations
Windows 10 support
Password API
User-defined filters for cross-references
Library handling
Unrestricted © Siemens AG 2017
Hardware configuration
S7-1500 CPU Portfolio has been enlarged by T-CPU
Page 3
Compact
CPU
Standard
CPU
Technology
CPU
ODK-
CPU
CPU-types 1511C-1
PN
1512C-1
PN
1511F-1
PN
1513F-1
PN
1515F-2
PN
1516F-3
PN/DP
1517F-3
PN/DP
1518F-4
PN/DP
1511TF-1
PN
1515TF-2
PN
1517TF-3
PN
1518F-4
PN/DP
ODK
Interfaces
Program/
Data memory
175 KB
1 MB
250 KB
1 MB
150/225 KB
1 MB
300/450 KB
1.5 MB
500/750 KB
3 MB
1/1.5 MB
5 MB
2/3 MB 8 MB
4/6 MB
20 MB
225/225 KB
1 MB
750/750 KB
3 MB
3/3 MB 8 MB
4/6 MB
20 MB1)
Bit-Performance 60 ns 48 ns 60 ns 40 ns 30 ns 10 ns 2 ns 1 ns 60 ns 30 ns 2 ns 1 ns
Width 85mm 110mm 35mm 35mm 70mm 70mm 175mm 175mm 35mm 70mm 175mm 175mm
Positioning axis
typical 2)
maximum 3)
5
10
5
10
5
10
5
10
7
30
7
30
70
128
128
128
5
10
7
30
70
128
128
128
Motion Control
Ressources 4) 800 800 800 800 2400 2400 10240 10240 800 5) 2400 5) 10240 5) 10240
2) at 4ms Servo/IPO cycle time and 35% CPU load due to Motion Control
1
1
1
1
1
1
1
1
1
1
2 1
1
2 1
1
2 1
1
2
3
1
1
2
3
1
1
1
1
2 1
1
2
1) 20 MB additional memory for ODK application
4) Ressources for Motion Control technology objects (examples): Speed setpoint: 40; Positioning: 80; Gearing: 160; Output cam: 20; Output camtrack: 160; Measuring input: 40
3) no further TO´s applicable
March 2017
PROFINET IO with IRT 2 PROFINET IO with RT 3 PROFINET basic services 1 5) Additional Number of Cam´s: 1511T: 20; 1515T: 60; 1517T: 128 PROFIBUS
New
Unrestricted © Siemens AG 2017
Easy handling of huge data amounts, which has to be kept retentive,
e.g. in order to save settings or parameterization data during power
off on the CPU.
Migration of S7-400 applications in factory automation is possible
Infeed of 60W into the backplane bus, integrated power balancing in
the TIA Portal, connection to 24/48/60 V DC
Energy buffering for data backup (up to 20 MB) in the CPU
Can be used with standard- and fail-safe CPUs
105mm width (can be plugged only on the left, next to the CPU)
I&M 0 … 3 („electronic rating plate“ with article number, version, etc.)
Highlights with PS 60W 24/48/60V DC HF
Customer benefits:
Page 4 March 2017
Hardware configuration
Configuration of the System Power Supply PS 60W 24/48/60V DC HF
Unrestricted © Siemens AG 2017
Configuration in STEP 7 V14 SP1
CPU firmware: V2.1,
power supply for the CPU is done via the backplane bus
Can be used with the following S7-1500 CPUs:
CPU 1511(F/T) up to CPU 1516(F) with
article number: 6ES751x-xyy01-0AB0 (starting with FS01)
CPU 1511C and CPU 1512C (starting with FS01)
CPU 1517(F) and CPU 1518(F) starting with FS03
FS: Hardware functional state
March 2017 Page 5
Precondition for Configuration
Hardware configuration
Configuration of the System Power Supply PS 60W 24/48/60V DC HF
Unrestricted © Siemens AG 2017
Hardware configuration
Configuration of the System Power Supply PS 60W 24/48/60V DC HF
Increased quantity structure for retentive data
Identical handling of retentive data like before
March 2017 Page 6
Unrestricted © Siemens AG 2017
Hardware configuration
Configure all IO channels of a module in a grid
Configure all I/O channels
of a module in a grid:
All of the channels of the
ET200MP DI&DQ HF
can be configured in one
grid.
Improved overview and
helpful functions like
auto fill, copy & paste for
diagnostics & IO
parameters
March 2017 Page 7
Unrestricted © Siemens AG 2017
Hardware configuration
Direct renaming of device names in the network and topology view
Direct renaming of device
names in the network and
topology view
Time savings thanks to
direct renaming in the
network and topology
view without opening the
device properties
Renaming via F2
shortcut, shortcut menu
or by double-clicking on
the device label
March 2017 Page 8
Unrestricted © Siemens AG 2017
Hardware configuration
Optimized (multi-)selection via shift key for network and device editor
1st click
Shift key
+ 2nd click
Optimized selection for
network and device editor
Quick (multi-)selection of
several devices and
modules with only two
mouse clicks
Support of device and
network editor in all
views
March 2017 Page 9
Unrestricted © Siemens AG 2017
Hardware configuration
Overview of IO tags of the complete IO station
Overview of all IO tags of
a complete IO station
Additional display for the
IO tags of the complete
IO station that are used
Display structured
according to modules for
easy assignment of the
IO tags to the hardware
March 2017 Page 10
Unrestricted © Siemens AG 2017
Hardware configuration
Easy removal of unused GSD files
1
2
3
Easy removal of unused
GSD files in the project
Cleaning up of
references to unused
GSD files in the project
Easy removing of
unused GSDs from
project with 3 clicks
March 2017 Page 11
Unrestricted © Siemens AG 2017
Hardware configuration
Improved zoom and overview navigation for the device and network editor
Improved zoom and
overview navigation for
the device and network
editor
The zoom function via
toolbar controls now
obtains the selected
object in the visible area
The overview navigation
shows the complete
configuration and
automatically optimizes
the display to the
available area
March 2017 Page 12
Unrestricted © Siemens AG 2017
Hardware configuration
Easy-to-find "PROFINET I/O system" properties
Easy-to-find "PROFINET
I/O system" properties
Properties now also
become visible by
selecting the subnetwork
All of the parameters of
the subnetwork and
PROFINET I/O systems
in the overview
March 2017 Page 13
Unrestricted © Siemens AG 2017
HWCN editors
Wizard extension for UDP multicast with Open User Communication (OUC) S7-1500 S7-1200 S7-300/400/WinAC
Wizard extension for UDP
multicast with Open User
Communication (OUC):
Easy UDP Multicast
configuration for programmed
or configured connections with
S7-1500 incl. CM/CP
Extension for CPU internal
interfaces of S7-1500 V2.1 or
higher
March 2017 Page 14
Unrestricted © Siemens AG 2017
TIA updater: Fast mass update
Openness: Ex/Import HW +IO via AutomationML
ProDiag: Criteria analysis for S7-Graph
Safety: Consistent Hardware- and Software Upload
Option handling with S7-1500F
F-IO-Status function block
6. TIA Portal options 2. STEP 7 - Innovations
Freely editable comments for array and UDT
New instructions
Single block comparison
User comments visible directly in the code
New technology object for SIMATIC Ident
3. WinCC - Innovations 5. System functions
1. Hardware configuration
Support for new hardware components
- CPU1511T(F) / CPU1515T(F)
- Power Supply 60W 24/48/60V DC HF
New functions for the operability
TIA Portal
Highlights of TIA Portal V14 SP1
March 2017 Page 15
Details
Optimized and extended
commissioning wizard
Online/offline comparison of parameter
values
4. Startdrive - Innovations
Windows 10 support
Password API
User-defined filters for cross-references
Library handling
Integration of SINUMERIK Operate in Runtime Advanced
OPC UA DA client for WinCC Runtime Professional
WinCC WebUX- Auto Login for WinCC RT Professional
Unrestricted © Siemens AG 2017
UDT and array comments can be changed instance-
specifically
Inheritance of defined comments by default
Multilingual support
S7-1500 S7-1200 S7-300/400/WinAC
Customer benefits
1. Display on the application
2. Use for message text
STEP 7 - Language innovations
Freely editable comments for arrays and UDTs
Function
3. Further benefits
Individual use of the
same UDTs
Unambiguous description
of array elements
March 2017 Page 16
New
Unrestricted © Siemens AG 2017
S7-1500 S7-1200 S7-300/400/WinAC
New
New
SCATTER* converts elementary
data types to a bit array
GATHER* converts a bit array to
an elementary data type
Expanded instructions
SCATTER_BLK and
GATHER_BLK for "array of data
type"
Converting data for
further processing
STEP 7 - Language innovations
New instructions: Scatter* / Gather*
Breaking down, processing and
status words
Example use case
March 2017 Page 17
* from FW V2.1 (S7-1500), V4.2 (S7-1200)
Unrestricted © Siemens AG 2017
New
0
1
2
3
4
5
6
7
0 1 2 3 4 5 6 7
x 1
Output=3.5
Input=5.5
Characteristic line is defined as
a polyline
Up to 50 points
Linear interpolation between
points
Input is mapped to
output via characteristic line
Use cases
Adaption of measured values
Linearization of actuators
with nonlinear characteristic
(e.g. compensation of valve
characteristics)
S7-1500 S7-1200 S7-300/400/WinAC
STEP 7 - Language innovations
New instructions: Polyline
March 2017 Page 18
Unrestricted © Siemens AG 2017
S7-1500 S7-1200 S7-300/400/WinAC
Generation of a diagnostic entry when a user-defined service life
is exceeded (in a percentage of the guaranteed read/write cycles)
Visual indicator on the CPU via the maintenance LED
Information in the user program can be evaluated via the
"GetSMCinfo" block:
Card size and memory that is already assigned
Number of write and delete processes carried out for the
card
"Service life" display of the SIMATIC memory card
RS ER MT
80%
FW
2.0
When recipes and archives are intensively used, information on
the "service life" of the card can be evaluated and the SMC card
can be swapped in advance if need be.
Field of application New
STEP 7 - Language innovations
New instruction: GetSMCinfo
March 2017 Page 19
New
Unrestricted © Siemens AG 2017
Easy back-up of various types of
data
Type safety because different UDTs
can be assigned
Compared to Serialize/Deserialize
clearly better runtime behavior
Various types of valves can be stored
or manipulated in an array
Customer benefits
Use case
STEP 7 - Language innovations
Symbolic programming UDT1 := UDT2
The various types of UDT must have the same structure of the
individual elements.
The symbolic names may differ.
Requirements
March 2017 Page 20
S7-1500 S7-1200 S7-300/400/WinAC
New
Programming example
:=
Unrestricted © Siemens AG 2017
STEP 7 - Language innovations
S7-Graph: Extension function block 1/2
S7-1500 S7-1200 S7-300/400/WinAC
With introduction of the expansion function
block for S7-Graph all static variables can be
accessed generically via the InOut interface.
The created extension function block can be
called as multi- or single instance.
Customer benefits
Indexed access to the whole sequence
Access to internal parameters like - number of active steps (SAX)
- number of disturbed steps (SERRX)
- number of valid transitions (TVX)
- and so on….
Basic principle
Call „My S7-Graph FB“
My S7-Graph DB
OB, FB, FC „My S7-Graph FB“,
My S7-Graph DB
New Extension
function block
March 2017 Page 21
Unrestricted © Siemens AG 2017
STEP 7 - Language innovations
S7-Graph: Extension function block 2/2
S7-1500 S7-1200 S7-300/400/WinAC
1) Create S7-Graph block (from V4.0)
2) Create Extension function block*
a) Define InOut parameters to access S7-
Graph variables
b) Sample program for indexed access to
steps and transitions
c) Sample program for access of internal
parameters
3) Define extension function block as multi
instanz within the static-section of
S7-Graph block
4) Define the extension block name
within the properties of the
S7-Graph block.
Workflow 1
4
2
2a
2b
2c
3
* SCL only
March 2017 Page 22
Unrestricted © Siemens AG 2017
STEP 7 - Technology
SIMATIC Ident: new technology object (TO) S7-1500 S7-1200 S7-300/400/WinAC
The technology object for SIMATIC
Ident is the link between the HW
design and the SW programming
The user allocates every device with
a unique name which is also used for
programming.
Parametrization of hardware by the
technology object
Diagnostic by displaying messages
that are produced within the
application software.
Basic principle
March 2017 Page 23
Unrestricted © Siemens AG 2017
STEP 7 - Technology
SIMATIC Ident: Adressing scheme using TO S7-1500 S7-1200 S7-300/400/WinAC
Easiest configuration
1. Design hardware and network. Assign
RFID devices with their own name.
2. Call the TO window and select a RFID
device.
3. Adjust all parameter for the selected
RFID device/reader.
4. Select a RFID device in your
application software. Only configured
devices are shown in the drop dwon
menu.
3. Adjust parameter
1. Design the hardware 4. Select device in
function block of the
application
2. Call TO
March 2017 Page 24
Unrestricted © Siemens AG 2017
STEP 7 - Trace
New options for graphical representation
4
3
1
Online
Offline
2
5
1. Preview window for the illustration
and choice of the current zoom area
2. Choice of the time format for the x-
axis
3. Display format for the number
representation switch-selectable
4. Switchover between steps and linear
interpolated signal (REAL)
5. Ongoing automatic measuring
repetition
Options
Customer benefit
Better Usability
Page 25 March 2017
Unrestricted © Siemens AG 2017
STEP 7 - Language innovations
Collection of useful function expansions
SCL: Surrounding a code that is used
Selected code lines can be encompassed
with control structures using the "Surround
with" function.
SCL: Insert and overwrite modes
You can switch between
insert and overwrite mode
using the Ins key.
Page 26 March 2017
Insert mode Overwrite mode
"Ins key"
New
New
Unrestricted © Siemens AG 2017
STEP 7 – Editor innovations
Collection of useful function expansions
Page 27 March 2017
Individual block comparison
The detailed comparison of individual
blocks can be started directly from the
project navigation.
Offline/offline but also online/offline
Display of the tag comment
In LAD/FBD, the tag comment can be
displayed directly on the application.
Hierarchical comments can also be
displayed
New
New
Unrestricted © Siemens AG 2017
STEP 7 - Editor innovations
Collection of useful function expansions
Tag comment in the watch table
The defined tag comment can also be
displayed in the watch table.
Inserting a comment line in the watch table
A comment line can be inserted using the
new icon.
"Open block/PLC data type..." via F7
The F7 function can also be started within
editors using Focus.
Page 28 March 2017
New
New
Unrestricted © Siemens AG 2017
STEP 7 - Editor innovations
Collection of useful function expansions
"Deep export" of external sources
The export of objects as an external source
takes the UDTs defined in the interface,
multi-instances and all called blocks into
consideration.
Upgrade of the project version to the latest
version
In the Instructions task card, the project can
upgraded to the latest version to be able to
use all of the new instructions.
Update of the instructions used in a
controller
All of the instructions used for a controller
can be updated to the latest version in the
Instructions task card.
Page 29 March 2017
New
New
New
Unrestricted © Siemens AG 2017
STEP 7 - Editor innovations
Collection of useful function expansions
Settings for library types
Under Settings/General/Library settings, the
type cancellation of objects can be
suppressed.
Protection for unintentional cancellation
of a typified object.
Settings for user-defined help
Under Settings/General, the user can select
whether the user-defined help is to be
opened in the selected editing language.
Page 30 March 2017
Terminate connection to type
Corporate
settings
New
New
Unrestricted © Siemens AG 2017
STEP 7 - Editor innovations
Collection of useful function expansions
Export of PLC tags used
The export of tag tables can be limited to
the tags used in the project.
Monitoring of blocks
When monitoring blocks it will be shown
whether online values are updated.
Page 31 March 2017
Ne
w
New
New
Unrestricted © Siemens AG 2017
TIA updater: Fast mass update
Openness: Ex/Import HW +IO via AutomationML
ProDiag: Criteria analysis for S7-Graph
Safety: Consistent Hardware- and Software Upload
Option handling with S7-1500F
F-IO-Status function block
6. TIA Portal options 2. STEP 7 - Innovations
Freely editable comments for array and UDT
New instructions
Single block comparison
User comments visible directly in the code
New technology object for SIMATIC Ident
3. WinCC - Innovations 5. System functions
1. Hardware configuration
Support for new hardware components
- CPU1511T(F) / CPU1515T(F)
- Power Supply 60W 24/48/60V DC HF
New functions for the operability
TIA Portal
Highlights of TIA Portal V14 SP1
March 2017 Page 32
Details
Optimized and extended
commissioning wizard
Online/offline comparison of parameter
values
4. Startdrive - Innovations
Windows 10 support
Password API
User-defined filters for cross-references
Library handling
Integration of SINUMERIK Operate in Runtime Advanced
OPC UA DA client for WinCC Runtime Professional
WinCC WebUX- Auto Login for WinCC RT Professional
Unrestricted © Siemens AG 2017
WinCC for Basic Panels
Collection of useful function expansions
Page 33 March 2017
Functional improvements for Basic Panel
Assignment of IP address is not limited to S7-1200 and S7-1500 anymore
USB Rescue Stick to reset Panel if connection is not possible
Siemens barcode scanners are now officially released with HMI Panels
Download Chinese/Japanese/Korean fonts to Basic Panel
(use of browser in these countries) via ProSave
Picture and text in parallel on a button
Unicode csv export of recipes on Basic Panels
USB Reset to Factory with USB stick
Creation of the USB stick
download of software
Unzip onto USB stick
Copy of Image from TIA folder into folder of USB stick
Start Basic Panel with inserted USB stick
Follow instructions
Restart the device
Available via download or from hotline
Preconditions:
USB is FAT32 formatted
Image is TIA V14 or higher
Unrestricted © Siemens AG 2017
WinCC for Comfort / Mobile Panel
Collection of useful function expansions
Page 34 March 2017
Functional improvements for Comfort / Mobile Panel
Uninstall WinCE applications for Comfort Panels (via ProSave)
Siemens barcode scanners are now officially released with HMI
Panels
Support of new network cameras
Unlimited usage of scripts (no system limit anymore)
Additional system functions in zone editor for Mobile
System function for restart of Comfort Panels
New supported printers:
Brother HL-5100DN (black laser)
Brother HL-L8250CDN (color laser )
Connectivity – Tested products
Support of Siemens barcode scanners
Optical handheld reading devices MV320/MV325/MV340
Update of tested network cameras
AXIS M1013, AXIS M1011
D-Link DCS-942L, D-LINK 4701E
https://support.industry.siemens.com/cs/ww/en/view/62383298
https://support.industry.siemens.com/cs/ww/en/view/19188460
Unrestricted © Siemens AG 2017
WinCC for Mobile Panels 2nd Generation and Runtime Advanced
Collection of useful function expansions
Page 35 March 2017
System functions for Mobile Panels 2nd Generation
Evaluation of the connection point
ShowPopUpScreen
ShowSlideInScreen
ShowLogonDialog
Log on user, log off user
VB script
General enhancements for Runtime Advanced
Camera view to display live video streams of current
network cameras over RTP/RTSP streaming protocols
and MJPEG, H264, MPEG4 codecs tested cameras
(AXIS M1013, AXIS M1011, D-Link DCS-942L, D-LINK
4701E, Siemens CCMS2025)
Extension of PDF view (Find and Copy)
License-free use of the Sm@rtServer on Runtime
Advanced (analogous to Comfort Panels)
ID 9 ID 8 ID 7
Unrestricted © Siemens AG 2017
WinCC Runtime Advanced
Integration of SINUMERIK Operate in Runtime Advanced
Access to SINUMERIK Operate user interface via new NC
Operate view in pictures of RT Advanced (also multitouch
operation)
Access to SINUMERIK NCU data by means of separate
SINUMERIK channel
Currently support of single-station solutions on SIMATIC IPC as
well as standard PC with Windows 7 Professional operating
system
Requires ES option SINUMERIK Integrate Create MyHMI/WinCC
as an enhancement for WinCC Advanced/Professional and RT
option SINUMERIK Integrate Run MyHMI/WinCC for operation
with WinCC Runtime Advanced
Requires SINUMERIK Operate/PCU or /PC as of version 4.8
SP1 or higher (customer-specific start of delivery scheduled for
May 2017)
Integration of SINUMERIK Operate (GUI and data)
in Runtime Advanced
March 2017 Page 36
Unrestricted © Siemens AG 2017
WinCC Runtime Professional
OPC UA DA Client
OPC UA DA Client
March 2017 Page 37
Unrestricted © Siemens AG 2017
WinCC Runtime Professional
Option WinCC/WebUX
Option WinCC/WebUX
March 2017 Page 38
Info about used licenses
Automatic Login ( “ViewOnly” for monitoring)
Use Case: information display in manufacturing hall
Unrestricted © Siemens AG 2017
WinCC Runtime Professional
Collection of useful function expansions
Collection of useful function expansions
March 2017 Page 39
Modal Popups with ScreenWindow
The screens, shown in screen window can be locked (no operation)
UseCase: InputMask, Messageboxes, ...
VBS Method: „SetOperationLock()“
Customizable Recipe Control
Possibility to configure the following properties:
Adapt the buttons (size and design)
Elements of table (individual symbols, also dependent from tags)
Scollbar (Style)
https://support.industry.siemens.com/cs/ww/en/view/76327375
Unrestricted © Siemens AG 2017
TIA updater: Fast mass update
Openness: Ex/Import HW +IO via AutomationML
ProDiag: Criteria analysis for S7-Graph
Safety: Consistent Hardware- and Software Upload
Option handling with S7-1500F
F-IO-Status function block
6. TIA Portal options 2. STEP 7 - Innovations
Freely editable comments for array and UDT
New instructions
Single block comparison
User comments visible directly in the code
New technology object for SIMATIC Ident
3. WinCC - Innovations 5. System functions
1. Hardware configuration
Support for new hardware components
- CPU1511T(F) / CPU1515T(F)
- Power Supply 60W 24/48/60V DC HF
New functions for the operability
TIA Portal
Highlights of TIA Portal V14 SP1
March 2017 Page 40
Optimized and extended
commissioning wizard
Online/offline comparison of parameter
values
4. Startdrive - Innovations
Details Windows 10 support
Password API
User-defined filters for cross-references
Library handling
Integration of SINUMERIK Operate in Runtime Advanced
OPC UA DA client for WinCC Runtime Professional
WinCC WebUX- Auto Login for WinCC RT Professional
Unrestricted © Siemens AG 2017
SINAMICS Startdrive V14 SP1
Optimized and extended commissioning wizard
March 2017 Seite 41
Integration of the previously two separated wizards
for standard commissioning and the use with a
SIMATIC Motion Control axis into one wizard
Integration of the selection of telegram, brake
resistance, filter at motor-side, temperature sensor
as well as Motor selection also by code number
Unrestricted © Siemens AG 2017
SINAMICS Startdrive V14 SP1
Collection of useful function expansions
Seite 42 March 2017
Online/offline comparison of parameter
values
Track changes online / offline
Sensitive support for saving data
“RAM to ROM”
Message box displayed when disconnecting
from the drive (only if parameters have been
edited)
Unrestricted © Siemens AG 2017
TIA updater: Fast mass update
Openness: Ex/Import HW +IO via AutomationML
ProDiag: Criteria analysis for S7-Graph
Safety: Consistent Hardware- and Software Upload
Option handling with S7-1500F
F-IO-Status function block
6. TIA Portal options 2. STEP 7 - Innovations
Freely editable comments for array and UDT
New instructions
Single block comparison
User comments visible directly in the code
New technology object for SIMATIC Ident
3. WinCC - Innovations Windows 10 support
Password API
User-defined filters for cross-references
Library handling
5. System functions
1. Hardware configuration
Support for new hardware components
- CPU1511T(F) / CPU1515T(F)
- Power Supply 60W 24/48/60V DC HF
New functions for the operability
TIA Portal
Highlights of TIA Portal V14 SP1
March 2017 Page 43
Details
Optimized and extended
commissioning wizard
Online/offline comparison of parameter
values
4. Startdrive - Innovations
Integration of SINUMERIK Operate in Runtime Advanced
OPC UA DA client for WinCC Runtime Professional
WinCC WebUX- Auto Login for WinCC RT Professional
Unrestricted © Siemens AG 2017
System functions
Win10-Support for TIA Portal V14 SP1 incl. V13 SP2
Supported operating systems
New
New
V13 SP2
V14 SP1
01/2020 Windows 7
10/2025 Windows 10
End of ext.
support:
Use case
project upgrade
V13 V14
Customer benefits
Long-term Microsoft Windows support with Windows 10
One shared operating system platform for TIA Portal and
"Classic products"
Project upgrade to a single-station computer :
Vxx V13 SP2 V14 SP1
March 2017 Page 44
* planned Q2/2017 * for STEP 7 / WinCC Basic also Windows 10 Home
*
Unrestricted © Siemens AG 2017
System functions
Password API
Protected
program
blocks
TIA Portal / STEP 7
Password prompt
via API
Integrated UI behavior:
Password prompt via dialog
KHP-PW
Central server management
with user authentication
User-specific hardware dongle
ID card with
Smartcard chip
Application examples
New
Open interface for 3rd party tools to connect to
the TIA Portal
Definition or administration of passwords in
external tools
Automatic opening of know-how-protected
blocks without entering a password
Supported protective mechanisms:
- Know-how protection for PLC objects
- Write protection for PLC objects
- Copy protection for PLC objects
Increased know-how protection because
passwords for the users are not visible/known
More convenient working with protective
mechanisms
Function
Customer benefits
Passw
ord
AP
I
March 2017 Page 45
Unrestricted © Siemens AG 2017
System functions
Filter options for cross-references
1 New 2
3
Example use case
As a user, I would like to find all variable write
accesses in a block greater than 1.
Workflow
1. Select all of the variables and open the
cross-references ("F11" or inspector window)
2. Define filter
3. The filter results show only multiple
accesses
Specific information is quickly found
Project-independent, can be saved and
exported
Customer benefits
Filter options
March 2017 Page 46
Unrestricted © Siemens AG 2017
Library
Export
System functions
Translation of libraries
B1 ENG GER
B2 ENG GER
V 1.0.0
V 0.3.2
Translation
ENG CHN
Text 1 …
Text 2 …
… …
ENG GER
ENG GER
V 1.0.0
V 0.5.9
ENG GER
ENG GER
Library
B1 ENG GER CHN
B2 ENG GER ITA
V 1.0.0
V 0.3.2
ENG GER
ENG GER
V 1.0.1 ENG GER CHN
V 1.0.0
V 0.5.9
ENG GER
ENG GER
V 1.0.1 ENG GER CHN
Import
Customer benefit
Translation of a library
Translation functions available for
project and
global libraries
The import/export of texts can be
done for a complete library, for
several library elements, or an
individual library element.
Consistent handling for copy
templates and types
March 2017 Page 47
Unrestricted © Siemens AG 2017
System functions
Library functions – Type upgrade – With TIA Portal V14 SP1
Function
Integration of deltaobjects for existing
types
System supported integration of
changed objects into an existing
library
Customer benefit Workflow
1. The filter shows all of the types that can
be upgraded
2. The user selects the test environment
3. The system checks the prerequisites
4. The system performs the upgrade of the
selected types
Blue markings appear if the types in the PLC_1 are instantiated.
1 2 4
3
Page 48 March 2017
Unrestricted © Siemens AG 2017
V13 SP1-Project V14 SP1 Project
V14 SP1 Engineering Software
Project Upgrade to V14 SP1
All project versions can be accessed via side-by-side Installation of V13 SP2 and V14.
V13 SP1/SP2
(usage also with V14 license )
Project Upgrade to V13 SP1
<= V13-Project
System functions
Project-Upgrade and Compatibility-Mode
Page 49 March 2017
V14 Project
Unrestricted © Siemens AG 2017
V14 Project
V14
V14 Engineering Software
V14 SP1 Project
V14 SP1
System functions
Online-Compatibility
Page 50 March 2017
No Online/Offline difference
No download or STOP necessary for:
Go Online
Monitoring blocks
Control variables
SW-Download in RUN (HW-Download always in STOP)
PLC-Upgrade from V14 to V14 SP1
Online access after upgrade of project
Customer benefits
No machine interruption by project upgrade
Program corrections can be downloaded in RUN
No lost of actual value
Upload in ES Download in PLC Online & Diagnosis Monitoring
Project Upgrade
Online Upgrade via
download in RUN
New
Unrestricted © Siemens AG 2017
System functions
Basic Integrity Check
TIA-Portal features a base-protective
mechanism to detect changes in custom project
file (e.g. blocks, hardware configuration).
Causes for changes for example can be
tampering outside the TIA-Portal or defects in
the data storage medium.
The TIA-Portal automatically extends integrity
information to the project file during save
operation
The check can be performed individually when
opening a project or generally during project
open (Global Setting)
Function
March 2017 Page 51
Improved detection of modifications on TIA-
Portal project files.
Customer benefits TIA-Portal
Project
File
Ad
din
g i
nte
gri
ty
info
rma
tio
n
Op
tio
na
l c
he
ck
of
inte
gri
ty i
nfo
rma
tio
n
TIA-Portal
Save project
Open project
1
2
1
2
Note: If basic integrity check is activated operating speed is reduced
when opening projects and especially in multi-user scenarios
Unrestricted © Siemens AG 2017
March 2017
System functions
Collection of useful function expansions
page 52
Write protection for program blocks
Password based write protection –
code visible but not editable
Also for failsafe block
(F signature is not changed)
Blocks still can be compiled
New properties and improved
usability in the alarm display
Receive alarms can be activated
within inspector window
With “freeze alarms” the view of the
alarm display can be frozen
New
New New
Unrestricted © Siemens AG 2017
TIA updater: Fast mass update
Openness: Ex/Import HW +IO via AutomationML
ProDiag: Criteria analysis for S7-Graph
Safety: Consistent Hardware- and Software Upload
Option handling with S7-1500F
F-IO-Status function block
6. TIA Portal options 2. STEP 7 - Innovations
Freely editable comments for array and UDT
New instructions
Single block comparison
User comments visible directly in the code
New technology object for SIMATIC Ident
3. WinCC - Innovations Windows 10 support
Password API
User-defined filters for cross-references
Library handling
5. System functions
1. Hardware configuration
Support for new hardware components
- CPU1511T(F) / CPU1515T(F)
- Power Supply 60W 24/48/60V DC HF
New functions for the operability
TIA Portal
Highlights of TIA Portal V14 SP1
March 2017 Page 53
Details
Optimized and extended
commissioning wizard
Online/offline comparison of parameter
values
4. Startdrive - Innovations
Integration of SINUMERIK Operate in Runtime Advanced
OPC UA DA client for WinCC Runtime Professional
WinCC WebUX- Auto Login for WinCC RT Professional
Unrestricted © Siemens AG 2017
Function
Multi-selection of support packages
Automatic download and installation of
several support packages
TIA Portal options
TIA Software Updater
Quick and easy adding of support
packages
Customer benefits
New New
TIA Software Updater
March 2017 Page 54
Unrestricted © Siemens AG 2017
Replacement of hardware configuration and icons via XML files
Bidirectional workflow CAD systems TIA Portal
Free tool support thanks to a standardized interface
Further use case, e.g. TIA Selection Tool connection
HWCN + IO
Exp
ort
/im
po
rt
PLC_1
XML file PLC_2
XML file
IO-
Device_1
AML file
Exp
ort
/im
po
rt
TIA Portal V14 SP1 Electrical CAD tools
Customer benefits
TIA Portal options
Openness: Standardized exchange between Electro-CAD and automation
Article number
Article description
Network connections
Configured firmware version
Tag table
New
March 2017 Page 55
Unrestricted © Siemens AG 2017
Project for Machine B
Project for Machine A
TIA Portal options
Openness: Automatic generation of projects, software and hardware
Project generator
DLL
TIA openness TIA Portal
Customer benefits
Generation of the
complete automation
project with TIA Portal
openness (hardware &
software)
Perfect customer workflow
from ordering to the
finished automated TIA
project.
March 2017 Page 56
Unrestricted © Siemens AG 2017
Why?
Original
problem
Switchover of the view to the original
state when an error has occurred.
Function
TIA Portal options
ProDiag: Criteria analysis in the HMI PLC Code Viewer
Customer benefits
Focusing on the erroneous operands
March 2017 Page 57
Unrestricted © Siemens AG 2017
TIA Portal Optionen
STEP7 Safety: Consistent Upload of Safety projects
K
R
E
I
S
CPU 1 ET200SP 1
CPU 3 ET200SP 3
CPU 2 ET200SP 2
Pro
ject
1
Pro
ject
2
Pro
ject
3
Service Techniker
Upload consistent
Avoidance of faults and
reduction of the service effort by
reduction of complex “offline”
administration
Time and cost savings
For S7-1500F and also
PLCSim Advanced
Customer benefits
Page 58 March 2017
Unrestricted © Siemens AG 2017
TIA Portal Optionen
STEP7 Safety: Configuration Control for F-I/O
K
R
E
I
S
F-modularization and fast
customization on customer wishes
without ES for serial production of
machines
Supported for F-Periphery
dezentralized for F-PLC S7-
300/400/1200/1500 und centralized
for F-CPU S7-1500
Controlling via F-Periphery-DB-
Variable „DISABLE“
Analysis of the F-BG-deactivation
via „DISABLED“ F-DB-Variable
Customer benefits
from Safety-System-Version V2.1
Page 59 March 2017 3/31/2017 Page 59
CP
U 1
Master-Project
CP
U 1
Option 1
CP
U 1
Option 2
Unrestricted © Siemens AG 2017
TIA Portal Optionen
STEP7 Safety: F-IO-Status function block
K
R
E
I
S
Collective information of channel- or F-I/O
faults for each failsafe Runtime Group
„QSTATUS“ Bit (QBAD + Value_Status)
Separate collection of the RIOforFA-
Value-Status for all F-IO modules
Extensions for further F-I/O information
planned (PASS_OUT, ACK_REQ,
IPAR_OK, …)
Customer benefits
New
March 2017 Page 60
Unrestricted © Siemens AG 2017
Thank you for your attention.
Page 61
Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may
not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested
performance features are binding only when they are expressly agreed upon in the concluded contract.
All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated companies or third parties.
Their unauthorized use may infringe the rights of the respective owner.
siemens.com/tia-portal
March 2017