Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two...
Transcript of Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two...
![Page 1: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/1.jpg)
Thesis Proposal
Brian ReganThe Virginia Historical Society Building
West Wing Addition
RICHMOND, VIRGINIA
![Page 2: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/2.jpg)
New Addition’s FunctionsAuditorium
Entrances located on ground and basement floors
MuseumArt Galleries are placed on the first floor
Office SpaceOffices and Conference rooms are located on the second floor
Learning CenterClassrooms are placed on the first floor
![Page 3: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/3.jpg)
Building Design Issues
Transition from historical vernacular to modern architecture
![Page 4: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/4.jpg)
Building Design Issues
Cont.)Create flow throughout building
Establish aesthetic attraction to new addition and spaces within
Create low cost energy efficient system
![Page 5: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/5.jpg)
Design Guidelines
Task
Appearance
Safety
![Page 6: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/6.jpg)
Transition Spaces
Vestibule (1)Foyer (2)Lobby (3)Prefunction (4)Corridor (5)Coat Room (6)
12 4
3
5 6
Spaces Lead to two different entrances of the auditorium
![Page 7: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/7.jpg)
Transition Spaces
Design PlansKeep all light fixtures consistent through sectionsAttract attention to Lobby AreaLighting to create flow for traffic Maintain proper illuminance for activities within the spaceProvide Adaptation at Entrances/Transition Spaces
Allows eyes to adjust to changing light levelsControl dimmers w/ manual preset system
Create feeling of space
![Page 8: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/8.jpg)
Transition Spaces
Design CriteriaControls – Dimming switches
Adaptation to changes in light levelsIlluminance
Horizontal > Vertical Facial rendering
Create traffic flowAppearance of the space
Brighter/Larger with low contrast ratio
![Page 9: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/9.jpg)
Transition Spaces
Lobby Existing ConditionsFloors – neutral colored carpetWalls: West – limestone
East – wood panelingCeiling – eggshell white/gypsum board
Height = 8ft.Columns – wood coverFunction – traffic and meeting space
![Page 10: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/10.jpg)
Transition Spaces
Lobby Design PlanRecessed wallwashers for East wall and linear wallwash for West Wall
Widens spaceCreates aesthetic feel Distinguishes types of material
Brings out texturePlace downlights in center of lobby
Contributes towards horizontal illuminanceInfluences flow of traffic
![Page 11: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/11.jpg)
Transition Spaces
Lobby Design PlanRecessed downlight
Linearwallwash
Low wattagewallwash
CFL wallwash
![Page 12: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/12.jpg)
Transition Spaces
Prefunction Existing ConditionsCeiling - 12ft and 15ft heightWalls: North wall – Stone paneling
South wall – Wood panelingWest wall – open to lobby w/ stairwellEast wall – 8’ in length
Floor – neutral colored carpetSublevel 8’ below ground floor
Functions – traffic and meeting space
![Page 13: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/13.jpg)
Transition Spaces
Prefunction Design CriteriaTransition Space Criteria AppliesAttract the eye from foyer
Accent height of spaceEmergency lighting for exiting auditorium
![Page 14: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/14.jpg)
Transition Spaces
Prefunction Design PlanFluorescent fixtures used to illuminate space
Dimming capabilitiesUniformly Wallwashes texture of materialsEfficiency
Use decorative pendants with high ceiling Draw attention to the space Increase appearance of size of the space
Place every two lamps on emergency circuit
![Page 15: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/15.jpg)
Transition Spaces
Prefunction Design PlanDownlights
Linear wallwash
wallwashers
?Decorative pendants
![Page 16: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/16.jpg)
Transition Spaces
Prefunction Design Plan
General area for decorative fixtures
North Wall Elevation
![Page 17: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/17.jpg)
Transition Spaces
Corridor Existing ConditionsWalls: South wall – limestone
North wall – wood panelingShortest distance between walls = 7ft.
Floor – sloped concrete w/ carpetCeiling – non sloped with gypsum board
Height ranges 8’2” to 12’10”
![Page 18: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/18.jpg)
Transition Spaces
Corridor Existing Conditions
North Wall Building Section
![Page 19: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/19.jpg)
Transition Spaces
Corridor Design CriteriaTransition Space Criteria appliesDevelop smooth transition and flow of trafficCreate feeling of wider spaceEmergency lighting for exiting auditorium
![Page 20: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/20.jpg)
Transition Spaces
Corridor Design PlanPlace linear wallwashers on both walls
Dimming capabilitiesWidens the corridorAccents materials with uniform lightingMore emergency lighting for exiting auditorium
Add low wattage decorative ceiling fixtures Keeps flow through the corridor
![Page 21: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/21.jpg)
Transition Spaces
Corridor Design PlanDecorative uplight
Linear wallwash
![Page 22: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/22.jpg)
Transition Spaces
Coat Room Existing ConditionsWalls – gypsum board – Eggshell white
North wall – coat rackFloor – neutral color carpetCeiling – gypsum board – eggshell whiteFunctions
Storage for belongingsEntrance into auditorium control room and electrical closet
![Page 23: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/23.jpg)
Transition Spaces
Coat Room Design CriteriaTransition Space Criteria AppliesColor rendering
Distinguish objects from each otherCRI > 85
Every Fixture used for emergency lighting
![Page 24: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/24.jpg)
Transition Spaces
Coat Room Design PlanPlace linear wallwashers along back wall
Adds emergency lighting to spaceDecorative uplight
Linear wallwash
![Page 25: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/25.jpg)
Auditorium
Existing ConditionsWalls – gypsum board w/ acoustical tiles
Back wall – fabric cover panelsCeiling – dropped w/ over lapping panelsFloor – neutral color carpet
Ramp angle = 4.7° and 7°Seating = 486 w/ 6 wheelchair spaces
South Wall Elevation
![Page 26: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/26.jpg)
Auditorium
Existing Conditions
![Page 27: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/27.jpg)
Auditorium
Design CriteriaControls
Manual preset system for dimmingEmergency panic switches
Functions – lectures, movies, displaysStage lighting
key, fill, back lighting Illuminance – 50 to 100 fc
Seating AreaIlluminance – 10 to 30 fc
![Page 28: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/28.jpg)
Auditorium
Stage Design PlanRecessed down lights above stage
Adjustable to act as key lighting and back lighting
Theatre lights8ft from stageLocated above ceiling panelProvides fill and back light
![Page 29: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/29.jpg)
Auditorium
Seating Design PlanAdd Cove/down lights at openings in ceiling
Wash ceiling for more luminanceProvides another scene Adds attractive accent to ceiling panels
Provide down light for seating areaPlace CFL downlights parallel w/ curved panel
Dimming capabilitiesProvide uniform lighting
![Page 30: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/30.jpg)
Auditorium
Seating Design PlanCustom design Down/Cove Light
Cove reflectorBallast
diffuser
4ft. section
Downlightreflector
![Page 31: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/31.jpg)
Auditorium
Design Plan Custom designed cove/downlight
CFLDownlights Stage recessed
downlighting
![Page 32: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/32.jpg)
Conference Room
Existing ConditionsWalls – Gypsum board – Eggshell whiteCeiling – White panels – 8ft. HighFloor – neutral color carpet
Two double door entrancesWest wall closet space
![Page 33: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/33.jpg)
Conference Room
Design CriteriaRatio – 3:1 for task and surroundingsFunctions
Presentations, Reading, HallwayGlare
27% reflectance from tableIndirect/semi-direct lighting
Facial RenderingControls – dimming switches
![Page 34: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/34.jpg)
Conference Room
Design PlanAbove table add 3 lamp dimmable indirect/semi-direct pendant
Provides different lighting scenes for different situationsLess glare from table
Install CFL downlights between entrances formore illuminance
Low wattage for minimal amount of lightIf conference room isn’t in use people still can travel through room
![Page 35: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/35.jpg)
Conference Room
Design Plan
wallsconce 4’ pendant recessed downlights
![Page 36: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/36.jpg)
Exterior
Existing ConditionsBuilding Envelope
Limestone VeneerAluminum panelsGround to roof glazing
Surroundings5ft. Sidewalk Limestone walkwayTrees in south lawn
![Page 37: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/37.jpg)
Exterior
Design CriteriaControls – Timing photosensorLight trespass
Glare through windowsExisting illuminated areas
Ratio – along façade 10:1Walk way lighting for high traffic areasCreate smooth transition of lighting details fromthe existing building to the addition
![Page 38: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/38.jpg)
Exterior
West and South Façade Design PlanHave continuous lighting in stairwells w/ glazingUse uplights on all limestone veneerUse downlights on all aluminum veneer
Bring out contrast between older and more modern materials
![Page 39: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/39.jpg)
Exterior
West and South Façade Design PlanIndoor lighting from first floor galleryDown lights located on patio between columnsFlood lights located at west wall aimed at aluminum siding
![Page 40: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/40.jpg)
Exterior
West and South Façade Design Plan
![Page 41: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/41.jpg)
Exterior
West and South Façade Design Plan
![Page 42: Thesis Proposal - Pennsylvania State University · Coat Room (6) 1 2 4 3 5 6 Spaces Lead to two different entrances of the auditorium. Transition Spaces ... Facial rendering ... Brings](https://reader034.fdocuments.us/reader034/viewer/2022050110/5f480543fd3c9d2a8807bdf9/html5/thumbnails/42.jpg)
Conclusion
Main GoalsCreate flow through building
Bring out textures of material
Develop smooth transition through spaces
Develop less costly/more efficient system