RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend...

8
M Ginniss & Fleming Mechanical Electrical Fire Protection Plumbing Engineering, Inc. c INDEX OF SHEETS MFE PROJECT 1640 - RICKARDS HIGH SCHOOL, BLDG. 20 - 100% CONSTRUCTION DOCUMENTS 3-17-17 1 3 4 5 6 14 19 10 12 11 45 41 9 8 7 21 20 22 13 17 16 18 Play Area N KEY PLAN BUILDING 20 AUDITORIUM E1.1 ELECTRICAL LEGEND AND NOTES E2.1 AUDITORIUM DEMOLITION PLAN E3.1 AUDITORIUM NEW WORK PLAN E4.1 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS E4.2 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS E4.3 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS E4.4 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS Tallahassee, Florida 32308 1401 Miccosukee Road - Suite 200 EB #05990

Transcript of RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend...

Page 1: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

The Best Place to Learn

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL

LEO COU TY SCHOOLSn n

To the best of my knowledge thesedrawings and the project manualare complete, and comply with the State Requirements for EducationalFacilities.

C. Kevin Fleming, PE

100% CONSTRUCTION DOCUMENTS

March 17, 2017

RICKARDS HIGH SCHOOL

Set No. _____

INDEX OF SHEETS

MFE

PR

OJE

CT

1640

- R

ICK

AR

DS

HIG

H S

CH

OO

L, B

LDG

. 20

- 100

% C

ON

STR

UC

TIO

N D

OC

UM

ENTS

3-1

7-17

BUILDING 20

LCS No. 330071

3

4

5

6

14 19

1012

11

45

41

9

8

7

212022

13

1716

18

JIM LEE ROAD

Pla

y A

rea

Driv

er's

Ed.

NPAUL RUSSELL ROAD

KEY PLAN

BUILDING 20AUDITORIUM

E1.1 ELECTRICAL LEGEND AND NOTES E2.1 AUDITORIUM DEMOLITION PLAN E3.1 AUDITORIUM NEW WORK PLAN E4.1 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS E4.2 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS E4.3 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS E4.4 AUDITORIUM STAGE LIGHTING SYSTEM DETAILS

LIGHTING REPLACEMENT

Florida Building Code, Building

Florida Building Code, Existing Buildings Florida Fire Prevention Code

and by referenceNFPA 70 National Electric Code

NFPA 101 Life Safety Code

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

2012 Edition (Florida)

2011 Edition

5th Edition (2014)5th Edition (2014)5th Edition

Project Overview

The mission of this project is replacement of the non-funtioning and outdated theatrical stsge lighting dimming and control system at James S Rickards High School. The project will include the installation of a new theatrical lighting dimming cabinet, control board, DMX signal distribution, and personel interface stations.

The existing theatrical control system will be removed entirely and turned over and delivered to the School District at their Tharpe Street Warehouse. All existing control cables will be replaced.

The power dimmer panel will be reconnected to an existing 208VAC service point. No modifications or additions to the building electrical distribution system are a requirement

All equipment shall be Electronic Theatrical Controls ETC. Basis of design is ETC Sensor 3 with ION control. Fixtures shall be ETC ColorSource 4 and as indicated. Complete commissioning by an ETC authorized entity is a requirement of the project.

Project Code Summary

All new work shall be constructed in accordance with the applicable codes currently adopted by the Authority Having Jurisdiction. Relevant Codes include the following:

Page 2: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

FIRE ALARM SYSTEM

CIRCUITING AND BRANCH CIRCUITSABBREVIATIONS

POWER, PANELS & POWER EQUIPMENT

J

J

HOMERUNS TO PANELS

LPA-2,4

LEGEND

JUNCTION BOXES AND OUTLETS

J PULL BOX REQUIRED FOR THEATRICAL LIGHTING CONNECTOR STRIP, EXISTING

EC

A AMPERE

AC ABOVE CEILING, ABOVE COUNTERTOP, ALTERNATING CURRENT

AFF MOUNTING HEIGHT ABOVE FINISHED FLOOR OR GRADE TO CENTERLINE

B ADJACENT TO LIGHT FIXTURE INDICATES FIXTURE TO BE EQUIPPED WITH EMERGENCY BATTERY PACK.

BFC BELOW FINISHED CEILING

CKT CIRCUIT

CW DEVICE MOUNTS IN CASEWORK BUT NOT FURNISHED WITH CASEWORK.

EC EMPTY CONDUIT (3/4" MINIMUM) WITH NYLON PULLWIRE

EM EMERGENCY

EWC ELECTRIC WATER COOLER LOCATION

EX EXISTING - RECONNECT AS REQUIRED AT EXISTING LOCATION. REMOVE AND REINSTALL IF REQUIRED

EMCS ENERGY MANAGEMENT CONTROL SYSTEM

ETR EXISTING TO REMAIN

FA FIRE ALARM

GFI GROUND FAULT INTERRUPTER

IC INTERCOM

J JUNCTION

NL NIGHT LIGHT

PNL PANEL

R RELAY

T TRANSFORMER, THERMOSTAT

V VOLT

VSD VARIABLE SPEED DRIVE

WP WEATHERPROOF (NEMA 3R)

HEAVY DUTY FUSED DISCONNECT SWITCH - EXISTING TO REMAIN

ARROW INDICATES CIRCUIT HOMERUNS IN CONDUIT

INDICATES HOMERUN TO CIRCUIT NUMBERS 2 & 4 IN PANEL "LPA"

NOTE: NUMBER OF HOMERUNS SHOWN ON THE PLANS ARE THE NUMBER OF HOMERUNS REQUIRED. DO NOT RUN MORE THAN THREE HOMERUNS IN ONE CONDUIT. DO NOT RUN 2 CIRCUITS ON THE SAME PHASE IN ONE CONDUIT.

INDICATES CONTINUATION OF RUN

CONCEALED OVERHEAD OR IN WALLS.

CONCEALED IN OR BELOW FLOORS OR GRADE.

EXPOSED SURFACE MOUNTED METAL RACEWAY.

FLEXIBLE CONDUIT TO EQUIPMENT

EMPTY CONDUIT WITH NYLON PULLWIRE - 3/4" MINIMUM UNLESS NOTED OTHERWISE.

JUNCTION BOX IN OR ABOVE CEILING

JUNCTION BOX IN WALL - MOUNT 1'-6" UNLESS NOTED OTHERWISE.

FIRE ALARM ADDRESSABLE RELAY MODULE

EXISTING FIRE ALARM CONTROL PANEL

J DMX

DCC

STAGE LIGHTING SYSTEM

DIMMING CONTROL CONSOLE AND FADERS

DIM DIMMER RACK AND DIMMERS

DMX PLUG-IN STATION

J DMX2 DMX PLUG-IN STATION - DUAL (DMX1/DMX/2)

SCOPE OF WORK1. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS REQUIRED TO COMPLETE ALL

ELECTRICAL WORK AS SHOWN ON THE CONTRACT DRAWINGS.

2. THIS SHALL INCLUDE THE INSTALLATION OF A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM. THIS SYSTEM REQUIRED CONSISTS BASICALLY OF, AND IS NOT LIMITED TO, THE FOLLOWING:

• EXTEND THE DISTRIBUTION SYSTEM FOR POWER INCLUDING THE NECESSARY FEEDERS, BRANCH CIRCUITS, INSTALLATION OF AND CONNECTION TO DEVICES, PANELBOARDS, TRANSFORMERS, SWITCHES, AND ALL OTHER EQUIPMENT SHOWN, AND THE CONNECTION TO OTHER POWER LOADS THAT ARE EXISTING OR NEW, PROVIDED BY OTHER CONTRACTS OR THE OWNER.

• EXTEND THE BUILDING GROUND SYSTEM AND PROVIDE SPECIAL GROUNDS AS INDICATED.

• INSTALL A SYSTEM OF EMPTY RACEWAYS, AND OUTLETS FOR THE NEW STAGE THEATRICAL LIGHTING SYSTEM.

• INSTALL THE POWER CONDUCTORS AND THE DIMMING EQUIPMENT SUPPLIERS CABLES, INCLUDING LOW VOLTAGE AND SIGNAL LINE CABLES AND CONDUCTORS.

• FURNISH AND INSTALL A COMPLETE AND SUITABLE THEATRICAL LIGHTING SYSTEM AS SHOWN AND SPECIFIED. COMMISSION THIS SYSTEM AND INSTRUCT THE OWNER IN ITS OPERATIONS

• FURNISH THE FIRE ALARM DEVICE, WIRING AND PROGRAMING TO PROVIDE A SIGNAL TO THE DIMMING CONTROLLER TO ACTIVATE GENERAL LIGHTING UPON ALARM.

• PERFORM THE DEMOLITION AND DISPOSAL WORK INDICATED.

3. THE BIDDER SHALL INSPECT THE PRESENT JOBSITE CONDITIONS BEFORE PREPARING HIS BID. THE SUBMISSION OF A BID WILL BE CONSIDERED EVIDENCE THAT SUCH A VISIT AND INSPECTION WAS PERFORMED BY THE BIDDER AND THAT HE TAKES FULL RESPONSIBILITY FOR ALL FACTORS GOVERNING HIS WORK.

4. THE WORK SHALL BE COMPLETE, FULLY OPERATIONAL, AND SUITABLE IN EVERY WAY FOR THE SERVICE REQUIRED. DRAWINGS ARE GENERALLY DIAGRAMMATIC IN NATURE AND DO NOT SHOW ALL DETAILS, DEVICES AND INCIDENTAL MATERIALS NECESSARY TO ACCOMPLISH THEIR INTENT. THEREFORE, IT SHALL BE UNDERSTOOD THAT SUCH DEVICES AND INCIDENTAL MATERIALS REQUIRED SHALL BE FURNISHED AT NO COST TO THE OWNER.

1. PHASING SHALL BE COORDINATED AND IN COMPLIANCE WITH ALL PHASING DRAWINGS AND NOTES.

2. ALL CONDUCTORS SHALL BE INSTALLED IN METAL CONDUIT OR TUBING. CONDUIT FOR BURIAL IN SOIL OR UNDER CONCRETE SHALL BE PLASTIC. FLEXIBLE CONDUIT INSTALLED OUT-OF-DOORS, IN ANY MECHANICAL EQUIPMENT ROOM, OR IN NORMALLY WET AREAS, SHALL BE LIQUID TIGHT FLEX WITH SUITABLE FITTINGS.

3. CONDUIT SHALL BE INSTALLED TIGHT TO DECK WHERE INSTALLED ABOVE CEILING. RELOCATE INCIDENTAL HANGERS, BRACKETS, ETC. WHERE IN CONFLICT. MAXIMIZE USE OF SPACE.

4. PROVIDE CONDUIT EXPANSION FITTINGS WITH BONDING JUMPERS FOR ALL CONDUITS PASSING THROUGH EXPANSION JOINTS.

5. ALL CEILING MOUNTED AND WALL MOUNTED EQUIPMENT OR DEVICES SHALL BE LOCATED TO AVOID DOOR SWINGS WHERE REQUIRED.

6. OUTLET BOXES OVER 16 SQUARE INCHES IN SMOKE AND FIRE WALLS MUST BE 5 SIDED WITH SAME CONSTRUCTION AS WALL SYSTEM. WHERE RECEPTACLES ARE ON OPPOSITE SIDES OF A FIRE WALL THERE SHALL BE A 24" HORIZONTAL SEPARATION BETWEEN THEM.

7. DO NOT MOUNT OUTLETS BACK TO BACK. THEY SHALL BE INSTALLED IN SEPARATE STUD SPACES.

8. CONDUIT SHALL PASS THROUGH WALLS AT 90 DEGREES AND SHALL BE RUN PARALLEL AND PERPENDICULAR TO WALLS.

9. BRANCH CIRCUITS AND HOMERUNS SHALL BE #12 WIRE AND 3/4" CONDUIT MINIMUM. EVERY CONDUIT SHALL HAVE A GREEN GROUND WIRE (#12 MINIMUM).

10. NO MORE THAN 3 PHASE CONDUCTORS SHALL BE INSTALLED IN ONE CONDUIT UNLESS NOTED OTHERWISE.

11. COLOR OF ALL NORMAL BRANCH RECEPTACLES, SWITCHES, ETC. TO BE ALMOND OR "OFFICE WHITE". COVERPLATES SHALL BE STAINLESS STEEL UNLESS NOTED OTHERWISE.

12. PROVIDE BARRIERS BETWEEN ALL 277V SWITCHES MOUNTED UNDER THE SAME COVER PLATE WITH OTHER 277V SWITCHES ON DIFFERENT PHASES OR WITH 120V SWITCHES.

13. MOUNTING HEIGHTS OF WALL OUTLETS ABOVE FINISHED FLOOR SHALL BE AS INDICATED IN THE LEGEND AND IN THE FOLLOWING TABLE UNLESS NOTED OTHERWISE ON THE PLANS (MOUNTING HEIGHTS ARE TO CENTERLINE OF DEVICE):

SWITCHES (GENERAL): 3'- 10" RECEPTACLES (GENERAL): 1'- 6"TELEPHONE AND NETWORK OUTLETS 1'- 6" (EXCEPT WHERE SHOWN AT

COUNTERTOPS)

14. MAINTAIN NEC MINIMUM CLEARANCE IN FRONT OF ALL SAFETY SWITCHES AND PANELBOARDS.

15. PRIOR TO ANY ROUGH-IN CONTRACTOR SHALL PROVIDE SCALED DRAWINGS (WITH ACTUAL DIMENSIONS OF APPROVED EQUIPMENT), UPON ENGINEER'S REQUEST, SHOWING LOCATIONS AND PROPER CLEARANCES OF ALL ELECTRICAL PANELS, TRANSFORMERS, CONTROL CABINETS, ETC. FOR APPROVAL. DRAWINGS WILL SHOW MECHANICAL, PLUMBING AND ARCHITECTURAL AS WELL AS ELECTRICAL EQUIPMENT.

16. ALL UNDERGROUND CONDUIT RUNS ENTERING THE BUILDING SHALL BE SEALED TO PREVENT THE ENTRANCE OF MOISTURE AND GASES.

17. ALL ITEMS ON PLANS ARE NEW UNLESS NOTED OTHERWISE.

18. EXISTING PANELS TO REMAIN SHALL HAVE THEIR PANEL SCHEDULES UPDATED AND RETYPED AFTER COMPLETION OF NEW WORK.

19. ALL WALL PENETRATIONS SHALL BE SEALED USING AN APPROPRIATE UL ASSEMBLY TO MAINTAIN THE RATING OF THE WALL.

20. ALL WALL AND CEILING DEVICES SHOWN ON THE NEW WORK PLANS REQUIRE CONCEALED RACEWAYS AND RECESSED METAL BOXES UNLESS NOTED OTHERWISE. COORDINATE WITH DEMOLITION TO REUSE EXISTING BOXES IN CMU WALLS WHERE THE CONDUITS AND BOXES ARE ACCEPTABLE. WHERE NEW BOXES OR RACEWAYS ARE REQUIRED IN EXISTING HOLLOW CELL CMU WALLS, CUT-IN BOXES AND FISH APPROVED FLEXIBLE METAL CONDUIT WITHIN THE CELL TO THE FIRST JUNCTION ABOVE CEILING. CONSULT WITH ARCHITECT FOR ALL LOCATIONS WHERE SURFACE RACEWAYS AND BOXES ARE REQUIRED TO COMPLETE THE CIRCUIT AND DEVICE ARRANGEMENTS SHOWN.

GENERAL NOTES1. ALL ELECTRICAL ITEMS SHOWN ON DEMOLITION PLANS ARE TO BE REMOVED UNLESS NOTED

OTHERWISE. RACEWAYS SUITABLE FOR REUSE MAY REMAIN. RACEWAYS INTENDED FOR REUSE MUST COMPLY WITH REQUIREMENTS FOR NEW RACEWAYS AND INSTALLATION.

2. ALL REMOVED ELECTRICAL EQUIPMENT, INCLUDING CIRCUIT BREAKERS, STARTERS, PANELBOARDS, TRANSFORMERS, FIXTURES, ETC. SHALL REMAIN THE OWNER'S PROPERTY AND SHALL BE TURNED OVER TO THE OWNER IN USEABLE CONDITION AT THE OWNER'S FACILITY ON THARPE STREET. ALL WIRES AND CABLES REMOVED SHALL BE COILED OR BUNDLED AND PLACED IN A CONTAINER AND TURNED OVER TO THE OWNER AT THE OWNER'S FACILITY ON THARPE STREET. DISPOSE OF ALL OTHER DEBRIS.

3. BLANKING PLATES SHALL MATCH NEW PLATES INSTALLED.

4. WHERE EXISTING CIRCUITS ARE REWORKED BY THE ADDITION OR REMOVAL OF CONDUCTORS, THE OLD WIRE SHALL BE REMOVED, THE CONDUIT SWABBED OUT, AND NEW WIRES OR CABLES REPULLED AS NEEDED.

5. IF ANY EXISTING ELECTRICAL EQUIPMENT THAT IS TO REMAIN BECOMES ISOLATED BY THE REMOVAL OF DEMOLISHED ELECTRICAL EQUIPMENT, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REROUTE AND RECONNECT THE EQUIPMENT SO THAT THE SYSTEM REMAINS OPERABLE. ANY REQUIRED WORK SHALL BE IN ACCORDANCE WITH SPECIFICATIONS.

6. RELOCATE EXISTING ELECTRICAL EQUIPMENT AS REQUIRED TO AVOID NEW CONSTRUCTION. ALL WORK REQUIRED SHALL BE PERFORMED IN ACCORDANCE WITH THE SPECIFICATIONS. ENGINEER SHALL BE NOTIFIED BEFORE PERFORMING WORK.

7. WHILE REMOVING ALL ELECTRICAL ITEMS INSIDE THE INDICATED ALTERATION AREA, RECONNECT CIRCUITS TO MAINTAIN INTEGRITY OF EXISTING CIRCUITS AND CONTINUED OPERATION OF LIGHTING, EQUIPMENT AND DEVICES TO REMAIN.

8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CUTTING OR PATCHING OF WALLS AND CEILINGS REQUIRED. CUTTING AND PATCHING WORK SHALL BE PERFORMED BY SKILLED CRAFTSMEN. RETURN ALL WALLS AND THEIR FINISHES TO ORIGINAL CONDITION.

9. ANY ITEM ABOVE CEILINGS IN EXISTING CORRIDORS OR ROOMS WHICH NEED TO BE RELOCATED FOR INSTALLATION OF NEW ELECTRICAL EQUIPMENT SHALL BE RELOCATED AND RECONNECTED AS REQUIRED. THIS INCLUDES BUT IS NOT LIMITED TO CONDUIT, WIRE, PIPING, AND DUCTWORK. RELOCATION SHALL BE MINIMUM DISTANCE POSSIBLE; PROJECT MANAGER SHALL BE NOTIFIED BEFORE BEGINNING WORK.

10. ABANDONED CONDUIT SHALL BE REMOVED WHERE POSSIBLE. ABANDONED CONDUIT IN SLAB OR CONCRETE WALLS WHICH CANNOT BE REMOVED SHALL HAVE WIRES PULLED FROM THEM. CUT OFF CONDUIT FLUSH WITH CONCRETE. PATCH OPENINGS AND PENETRATIONS WITH GROUT AND GRIND OR TROWEL SMOOTH, READY FOR NEW FINISH.

11. ANY AND ALL HOLES OR DAMAGED SURFACES DUE TO DEMOLITION WORK SHALL BE PATCHED BY A SKILLED CRAFTSMAN.

12. WHERE ITEMS ARE DESIGNATED EXISTING TO REMAIN, THEY SHALL BE PROTECTED DURING DEMOLITION. RELOCATE AS REQUIRED WHERE ITEMS ARE INSTALLED IN CEILING. WHERE RECEPTACLES ARE NOT EXISTING TO REMAIN, NEW DEVICES AND WALLPLATES SHALL BE INSTALLED AND NEW THHN CONDUCTORS INSTALLED IN EXISTING RACEWAY.

DEMOLITION NOTES - GENERAL

R FA

FACP

22" HDMI FLAT PANEL DISPLAY WITH STAND

DMX DMX OPTICAL SPLITTER

HOUSE EXISTING LIGHTING CONTROLS TBR

WALL CONTROL - PRESET STATION WITH OFF

WALL CONTROL - PRESET STATION WITH OFF AND PROGRAMMABLE SLIDERS

SP

SF

SHEET:

March 17, 2017

.

REVISED:

.

.

Tallahassee, Florida

DATE:

RICKARDS HIGH SCHOOL

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL LIGHTING

SHEET TITLE:

LEON COUNTY SCHOOLS

JOB NUMBER:1640

DRAWN BY:DESIGNED BY:

100% CONSTRUCTION DOCUMENTS

SUBMITTAL:

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

NOTES

Charles K. Fleming, PE #48107

CONTROLS REPLACEMENT

BUILDING 20

LEO COU TY SCHOOLSn n

E1.1

ELECTRICALLEGEND ANDNOTES

CKF TEB

Page 3: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

CHAIRLIFT

BOYS DRESSING20-009

GIRLS DRESSING20-010

VESTIBULE800

GIRLS HC20-010A

WOMENS20-006

JAN20-005

CONTROL20-004

LOBBY20-001

TICKET20-003

MENS20-002

FIRE PUMP20-011A

WORKROOM20-011

BOYS HC20-009A VESTIBULE

800

ORCHESTRA PIT

PROSCENUM

AUDITORIUM20-007

1 HR

1 HR

STAGE20-008

COVERED WALK20-801

COVERED WALK20-801

HO

US

E

Remove existing house lighting control

HO

US

E

Remove existing house lighting control

DIM

HO

US

E

Remove existing house lighting control

Dimmer cabinet - deliver to LCS Warehouse

HOUSE

Remove existing house lighting control

Remove branch circuit between disconnect and dimming enclosure

Disconnect - ETR

DC

C

Turn over to LCS

1. Deliver existing dimmer module ETC L86 and all rack mounted components to the LCS Warehouse 3120 West Tharpe Street and unload on their dock. Other materials to be turned over to the Owner or disposed of in accordance with general notes.

2. Owner shall salvage existing Acclaim control console. Protect during demolition and salvage.

3. Remove all control cables.4. Oversize backboxes (for multi-slider controls) may be

reused for pushbutton control stations. Provide finished coverplate, painted black, with suitable openings for new stations.

5. Work on energized equipment is not allowed under any circumstances.

SHEET:

March 17, 2017

.

REVISED:

.

.

Tallahassee, Florida

DATE:

RICKARDS HIGH SCHOOL

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL LIGHTING

SHEET TITLE:

LEON COUNTY SCHOOLS

JOB NUMBER:1640

DRAWN BY:DESIGNED BY:

100% CONSTRUCTION DOCUMENTS

SUBMITTAL:

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

NOTES

Charles K. Fleming, PE #48107

CONTROLS REPLACEMENT

BUILDING 20

LEO COU TY SCHOOLSn n

E2.1

ELECTRICALAUDITORIUM DEMOLITIONPLAN

CKF TEB

N

AUDITORIUM DEMOLITION PLANSCALE: 1/8"=1'-0"

1E2.1

Page 4: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

CHAIRLIFT

BOYS DRESSING20-009

GIRLS DRESSING20-010

VESTIBULE800

GIRLS HC20-010A

WOMENS20-006

JAN20-005

CONTROL20-004

LOBBY20-001

TICKET20-003

MENS20-002

FIRE PUMP20-011A

WORKROOM20-011

BOYS HC20-009A VESTIBULE

800

ORCHESTRA PIT

PROSCENUM

AUDITORIUM20-007

1 HR

1 HR

STAGE20-008

COVERED WALK20-801

COVERED WALK20-801

DIM

DC

CD

IMD

CC

DIM

JDMX2

New house lighting control station; 4 button preset

New cable in existing raceway to dimmer rack

J

3/4" C.

New house lighting control station; 4 button preset with faders

New cable to dimmer rack, Belden 9729 and #14G

Connect new house controls; raceways can be reused.

SP

SFNew cable to dimmer rack, Belden 9729 and #14G

DMX2

J

J

New BELDEN #9729 and #14 stranded green ground (typ)

16 Circuit distribution rail, existing to remain. Typical of (4). Provide a new DMX input terminal box for each distribution rail.

Mezzanine WalkwayJ J JJ

DMX2J J

DMX2DMX2New house lighting control station; 4 button preset

New cable to dimmer rack, Belden 9729

SF

Existing lighting circuits, no modifications

Terminal cabinet, existing to remain (typ)

Tie new DMX cables to rigging cables according to manufacturer's instruction

Existing400A FusedDisconnect

New Dimming Cabinet

Reconnect new dimming cabinet to existing circuit breaker; feeder circuit shall be replaced with new4-500KCMIL, 1-#3 G

New cable to dimmer rack, Belden 9729

SF

JDMX2

Located beneath countertop

DMX

R FA

FACP

CHAIRLIFT

BOYS DRESSING20-009

GIRLS DRESSING20-010

VESTIBULE800

GIRLS HC20-010A

WOMENS20-006

JAN20-005

CONTROL20-004

LOBBY20-001

TICKET20-003

MENS20-002

FIRE PUMP20-011A

WORKROOM20-011

BOYS HC20-009A VESTIBULE

800

ORCHESTRA PIT

PROSCENUM

AUDITORIUM20-007

1 HR

1 HR

STAGE20-008

COVERED WALK20-801

COVERED WALK20-801

1. Refer to line diagram for all wiring and cable requirements. Provide the materials specified or equivalent with ETC Lighting Inc written approval.

2. Replace service feeder between distribution circuit breaker and dimming cabinet complete.

3. Three scene pre-programmed control station shall be programmed for assembly or general use. Furnish and install the three (3) new control stations in the locations shown to provide 4-button preset controls to house lighting. One station shall have slider capability. Channels shall be selected by Owner.

5. All control cables shall be new. Coordinate with system provider for quantities and types and contract responsibility.

6. Sesco/ETC shall provide system check and programming/presets and their price shall be included in the Contractor's basic price.

7. Contractor/ETC shall include effort to program all presets in accordance with RHS Staff wishes.

8. Provide painted trims and covers for a first rate installation where larger control stations are replaced with small; back boxes may be reused.

9. Label all cables in the main DMX junction box or dimming rack as appropriate.

10. Provide new supervised relay to activate existing house lighting emergency transfer system automatically upon fire evacuation alarm.

11. Provide new labels, warnings, touchup painting, etc as required for a true "refurbished" system.

SHEET:

March 17, 2017

.

REVISED:

.

.

Tallahassee, Florida

DATE:

RICKARDS HIGH SCHOOL

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL LIGHTING

SHEET TITLE:

LEON COUNTY SCHOOLS

JOB NUMBER:1640

DRAWN BY:DESIGNED BY:

100% CONSTRUCTION DOCUMENTS

SUBMITTAL:

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

NOTES

Charles K. Fleming, PE #48107

CONTROLS REPLACEMENT

BUILDING 20

LEO COU TY SCHOOLSn n

E3.1

ELECTRICALAUDITORIUM NEW WORKPLAN

CKF TEB

N

AUDITORIUM NEW WORK PLANSCALE: 1/8"=1'-0"

1E3.1

Page 5: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

ISOMETRIC VIEW

3.54

(90mm)

4.23

(108mm)

FRONT VIEW

BOTTOM VIEW

TOP VIEW

2.28

(58mm)

SIDE VIEW

Active

DMX Data

RDM Data

Error

9 - 48V DC

DMX OUT 4DMX OUT 3DMX OUT 2DMX OUT 1

CDMX THRU

CDMX IN

Active

DMX Data

RDM Data

Error

9 - 48V DC

DMX THRU

C

DMX IN

C

NOTES:

OF A BLACK EXTRUDED PLASTIC.

1.) OPTO SPLITTER COVER AND END CAPS ARE CONSTRUCTED

FOR THE FOLLOWING STANDARDS:

3.) OPTO SPLITTER MEETS OR EXCEEDS REQUIREMENTS

OF EXTRUDED ALUMINUM. BACK SHELL IS CONSTRUCTED

2.) OVERLAYS ARE DIGITALLY PRINTED LEXAN WITHBLACK NOMENCLATURE ON A CREAM BACKGROUND.

CM

(SEE DWG. 07)

PLUG-IN STATION

(BY OTHERS)

3 PHASE, 4 WIRE+GND.

120/208 VAC400A

60Hz.

SENSOR3 SR3-48

DIMMER RACK

(SEE DWGS. 04 THRU 06)

D1/D2

TO DMX DEVICE

(BY OTHERS)

~

ION

(SEE DWGS. 08 & 09)

CONTROL SYSTEM

(2) 25' DMX CONTROL CABLES(BY ETC)

DMX WIRING

End Termination Point

Start Termination Point

Pass through

Splice

Termination Point

CONTROL WIRING LEGEND

(DMX INPUT)

(1) BELDEN #9729D*

NOTES:

* = WIRE IDENTIFICATION NUMBER (NOT QUANTITY)

1.) ALL CONTROL WIRING IS PROVIDED BY OTHERSUNLESS NOTED OTHERWISE.

(1) BELDEN #9729

(1) BELDEN #9729

(1) BELDEN #9729

UNISON CONTROL

STATION (TYP)

(1) BELDEN #9729

ECHO PRESET

STATION (TYP)

DMX CONTROL SPLITTER ASSEMBLY DETAIL

NOT TO SCALE

SYSTEM FUNCTIONAL DIAGRAM

NOT TO SCALE

THEATRICAL LIGHTING INSTRUMENTS

C - CLAMP, SAFETY CABLE, GEL FRAME, STAGE PIN CONNECTOR

TYPE QTY. LAMP TYPE

DESCRIPTION OPTION

25deg - 50deg ZOOM

ZOOM 2 HPL575

BARRELS FOR ABOVE BODIES

4 @ 19°2 @ 26°2 @ 36°2 @ 50°

10 GOBO FRAMES

PAR 4 COLORSOURCE PAR WITH LENS/GEL FRAME

C - CLAMP, SAFETY CABLE, GEL FRAME, STAGE PIN CONNECTOR

CYCLIC LIGHTS

6 LIGHT EMITTING DIODE

LED CYC ADAPTER PROFILE SPOTLIGHT SERIES WITH BODY

C - CLAMP, SAFETY CABLE, GEL FRAME, STAGE PIN CONNECTOR, BLACK ENAMEL STEEL HOUSING

NOTES

1. FIXTURES SHALL BE ELECTRONIC THEATRE CONTROLS, INC. SOURCE 4 SERIES. ALL FIXTURES 120V.2. CYCLORAMA WASH LIGHTING SHALL INCLUDED CYC ADAPTER AND SOURCE FOUR LED LIGHT ENGINE.3. PROVIDE QTY (20) REPLACEMENT LAMPS, TYPE HPL575.4. PROVIDE QTY (30) GELS IN MANUFACTURER'S STANDARD PRIMARY AND SECONDARY COLOR ASSORTMENT (5 EACH).

MANUFACTURER'S STANDARD BODY

ELLIPSOIDALSPOT

6 C - CLAMP, SAFETY CABLE, GEL FRAME, STAGE PIN CONNECTOR

LIGHT EMITTING DIODE

LIGHT EMITTING DIODE

DMX

SHEET:

March 17, 2017

.

REVISED:

.

.

Tallahassee, Florida

DATE:

RICKARDS HIGH SCHOOL

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL LIGHTING

SHEET TITLE:

LEON COUNTY SCHOOLS

JOB NUMBER:1640

DRAWN BY:DESIGNED BY:

100% CONSTRUCTION DOCUMENTS

SUBMITTAL:

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

NOTES

Charles K. Fleming, PE #48107

CONTROLS REPLACEMENT

BUILDING 20

LEO COU TY SCHOOLSn n

E4.1

ELECTRICALAUDITORIUM STAGE LIGHTINGSYSTEM DETAILS

CKF TEB

Page 6: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

4.) 6" MINIMUM CLEARANCE REQUIRED ON LEFT SIDE OFRACK FOR DOOR SWING & MODULE INSERTION/REMOVAL.

6.) DIMMER RACK IS LISTED.

FAN FOR EXHAUST FROM DIMMER RACK.

3.) 10" MINIMUM CLEARANCE REQUIRED ABOVE

FINISHED IN A BLACK FINE-TEXTURED POWDER COAT.

1.) DIMMER RACK ENCLOSURE IS 16 GA. FORMED STEEL

2.) DIMMER RACK IS DESIGNED FOR FRONT ACCESS LOAD WIRING AND TOP OR BOTTOM FEED WIRING.

NOTES:

TERMINATION

GROUND

(TYPICAL)

TOP VIEW

.77

1.09

2.54

3.00

19.80

14.80

12.62

8.97

LINE/LOAD ACCESS PANEL(TYPICAL OF TOP & BOTTOM)

10" EXHAUST FAN

NEUTRAL LINE/LOADTERMINATION

RIGHT SIDE REMOVED TO

SHOW CIRCUIT NUMBERING( )

22.80

(TYPICAL)

DIMMER MODULE

MODULE

CONTROL

ELECTRONICS

CONTROL

TERMINATION

CONNECTORS

)( MODULE BACKPLANE

LOCATED ON REAR OF

LOAD

TERMINATION

LOCKABLE DOOR

FRONT VIEW

(LOCKABLE DOOR & MODULES REMOVED)

(TYPICAL BOTH SIDES)

BUSSING ACCESS PANEL

ERROR INDICATION BEACON

82.70

14.80

LEFT SIDE VIEW FRONT VIEW

(LOCKABLE DOOR ASSEMBLY REMOVED)

FRONT VIEW

BOTTOM VIEW

1.00

(ADJUSTABLE TO 2.00)

TERMINATION

LINE

(TYPICAL EACH PHASE)

)(SHOW CIRCUIT NUMBERINGRIGHT SIDE REMOVED TO

TERMINATION BAR

GROUND

5.) DIMMER RACK SHORT CIRCUIT CURRENT RATING (SCCR)IS 100,000 AMPS.

34

45

46

39

40

3

28

33

22

27

21

10

15

16

4

9

80

92

91

85

86

73

74

79

67

68

56

62

61

49

50

55

38

43

44

32

37

14

25

26

31

20

19

7

8

13

2

1

65

96

89

90

95

83

84

72

77

78

66

71

93

30

59

60

48

53

54

42

47

41

35

36

23

24

29

17

18

6

11

12

94

5

58

87

88

76

82

81

69

70

75

63

64

52

57

51

PHASE A

PHASE B

PHASE C

22.80

95,

D20

D20

D20

D20

D20

89,

83,

71

77,

,

65,

,

D20

D20

D20

D20

D20

47

59,

53,

,

41,

35,

D20

D20

D20

D20

D20

23

29

,

17,

5

11,

,

93,

D20

D20

D20

D20

D20

75

87,

81,

,

69,

63,

D20

D20

51

57,

,

96

90

84

72

78

66

48

60

54

42

36

24

30

18

6

12

94

76

88

82

70

64

52

58

D20

D20

45,

39,

3D20

D20

D20

D20

D20

D20

27

33

,

,

21,

,

15,

9

,

D20

D20

D20

D20

79,

91,

85,

73,

67,

31D20

D20

D20

D20

D20

D20

55

61

,

,

49,

43,

37

,

,

D20

D20

D20

D20

D20

25,

19,

7

13

,

,

1,

46

40

4

28

34

22

16

10

80

92

86

74

68

32

56

62

50

44

38

26

20

8

14

2

R

9.13

D20

D20

D20

PHASE

LINE FEED

A B

LINE FEED

PHASE PHASE

LINE FEED

CNEUTRAL

MODULE SLOT 1

ASSEMBLY

SCR

TYPICAL DUAL CHANNEL DIMMER MODULE

FOR LOAD TERMINATION

NEUTRAL BUS ASSEMBLY

FAN

CHOKECH.2 C.B.

CH.1 C.B. CHOKE

CEM3 CONTROL ELECTRONICS MODULE

J9

J1, J10, J11, J12, J17

BEACON

ASSEMBLY

P.C.B.CONTROL

INPUT

RIBBON CABLE ASSEMBLY

TERMINAL

LOAD

LOAD

TERMINAL

GROUND

J18

BACKPLANE

SENSOR3 RACK ELECTRICAL DIAGRAM

REAR OF ELECTRONICS MODULE BACKPLANE

POWER CONNECTOR

STATION/PANIC

STATION +

BEACON

+24VDC

PANIC SEND

PANIC RETURN

5

STATION -

7

8

6

4

2

3

1

J1

8

6

7

2

4

5

3

1

J11

DMX CONNECTORS

ISO COMMON

DMX IN +

DMX IN -

7

8

6

5

4

3

2

1

J10

7

8

6

5

4

3

2

1

J12

ISO COMMON

DMX IN +

DMX IN -

ISO COMMON

DMX A (THRU) +

DMX A (THRU) -

DMX B (THRU) +

DMX B (THRU) -

ISO COMMON

6

8

7

5

4

2

3

1

J17

R2

R4

T4

T1

R1

R3

T2

T3

NETWORK CONNECTOR

(DMX A)

(DMX B)

(DMX THRU)

COMMON

PANIC OUT

PASS-THRU

DMX B DMX A DMX B

COM

DMX A

-+ -+ COM -+ COM -+ COM

ON-

OFF-

RDM-

DMX TERMINATION

B A

24VDC

BEACON

PANIC OUT

COMMON

STATION +

STATION -

NO

NC

DISABLEDEMERGENCY

CONTACT

SEE UNDERSIDE OF

CEM3 FOR DIP SWITCH

SETTINGS

J1

BATTERY/

THRU

RIDE-

J20

J20J9 J17

J10J11J12

FAN

NEUTRAL

PHASE C

5

PHASE A 6

4

2

3

1

J9

GROUND

PHASE B

FRONT OF ELECTRONICS MODULE BACKPLANE

S1S3S2

EMERGENCY CONTACT

BATTERY/RIDE-THRU

COMMON

+24VDC

2

1

J20

J18

CONTROL DISTRIBUTION ASSEMBLY

(TYPICAL OF 4)

(TYPICAL OF 4)

MODULE SLOTS

2 - 16

17 - 32

MODULE SLOTS

MODULE SLOTS

33 - 48

DMX TERMINATION CHART

DMX SWITCH SETTING

RACK DMX B DMX A

1 OFF ON

S2 & S3

S1

N.O. (UP)

DISABLED (MIDDLE)

N.C. (DOWN)PANIC SEND

PANI

C RE

TURN

SENSOR D20 OFF

OFF

Signal

D20

SignalDUAL 20A. (2.4 kW) DIMMER MODULE

CONTROL ELECTRONICS MODULE

SENSOR CEM3

SENSOR MODULES(FRONT VIEWS)

1

C

D

48

Power DMX A DMX A Network Panic

Reset

Test

About Back

Setup

Enter

Enter

thru

and

atdef

mno

wxyz

jkl

abc

tuv

#navLast

A

Next

B

pqrs

ghi

DIM

DIMMER RACK AND CONTROL

NOT TO SCALE

SHEET:

March 17, 2017

.

REVISED:

.

.

Tallahassee, Florida

DATE:

RICKARDS HIGH SCHOOL

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL LIGHTING

SHEET TITLE:

LEON COUNTY SCHOOLS

JOB NUMBER:1640

DRAWN BY:DESIGNED BY:

100% CONSTRUCTION DOCUMENTS

SUBMITTAL:

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

NOTES

Charles K. Fleming, PE #48107

CONTROLS REPLACEMENT

BUILDING 20

LEO COU TY SCHOOLSn n

E4.2

ELECTRICALAUDITORIUM STAGE LIGHTINGSYSTEM DETAILS

CKF TEB

Page 7: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

4.) CONTROL CONSOLE INCLUDES MOUSE, KEYBOARD, (3) IEC

5.) CONTROL CONSOLE MEETS OR EXCEEDS REQUIREMENTS FOR

AND CHASSIS IS CONSTRUCTED OF .062 ALUMINUM. BOTH

1.) CONTROL CONSOLE FACE PANEL IS .075 GALVANIZED STEEL

3.) APPROXIMATE WEIGHT OF UNIT IS 20.35 lbs. (9.23 kg).

NOTES:

2.) FACE PANEL AND REAR PANEL NOMENCLATURE IS

THE FOLLOWING MARKINGS:

REVERSE-SILKSCREENED ONTO ADHESIVE LEXAN LABELS.

17.89

(454mm)

ISOMETRIC VIEW

SIDE VIEW FRONT VIEW

TOP VIEW

REAR VIEW

18.24

(463mm)

5.19

(132mm)

(3/4 SCALE)

POWER CABLES (US/UK/Schuko), USB FLASH DRIVEAND DUST COVER (NOT SHOWN FOR DRAWING CLARITY).

ARE FINISHED IN A BLACK FINE-TEXTURED POWDER COAT.

PUSHPUSH

MIDIOut In

DMX

1

DMX

2

Remote Trigger

Phone Remote

Delay TimeHang

Follow

Sub GroupPreset

UpdatePalette Palette

Color Beam

OnlyPalette Palette

Int Focus Record

Cue RecordPart

0 .Clear

2 31

64 5

97 8

Thru -+

Track

Q Only

At Enter

Full

Out Last

Select

Dim

Rem

Home

Sneak/

Capture Next

Park LastFrom

Recall

Undo

Copy To

Block

About

Cue

Go To

Note

Label

Effect

Learn

Help

Macro

Delete

Out

Black

Load Control

Fader

S1 S2 S3 S4 S5 S6 SK

More

Custom

Shutter

Color

Image

Focus

Form

Displays

Data

Blind

Expand

Live

Format

FlexiSwap Lock

Scroll

SelectPageEscape

Page PagePage

GO

BACK

STOP

100-240VAC

50/60Hz 2A

Electronic Theatre Controls, Inc. Middleton, WI USA

C US

3060167

AC Input

CM

4.) USB CABLE, POWER CABLE AND DUST COVER

5.) FADER WING MEETS OR EXCEEDS REQUIREMENTS FOR

3.) APPROXIMATE WEIGHT OF UNIT IS 8.0 lbs. (3.7 kg).

NOTES:

2.) FACE PANEL AND REAR PANEL NOMENCLATURE ARE

THE FOLLOWING MARKINGS:

REVERSE-SILKSCREENED ONTO ADHESIVE LEXAN LABELS.

ISOMETRIC VIEW

(3/4 SCALE)

17.89

(454mm)

TOP VIEW

REAR VIEW

15.93

(405mm)

SIDE VIEW

IS FINISHED IN A BLACK FINE-TEXTURED POWDER COAT.

1.) FADER WING IS CONSTRUCTED OF .062 ALUMINUM AND

FRONT VIEW

5.25

(133mm)

ARE INCLUDED BUT NOT SHOWN.

2 X 20 Fader Wing

C US

12VDC, 1A

Electronic Theatre Controls, Inc.

Middleton, WI USA

www.etcconnect.com

2 X 20 Fader Wing

CUS

12VDC, 1A

Electronic Theatre Controls, Inc.

Middleton, WI USA

www.etcconnect.com

SP

UNISON CONTROL STATION UH51007

ECHO 4-BUTTON PRESET CONTROL

STATION

SF

WALL CONTROLS

CONSOLE AND EXPANDER WING

NOT TO SCALEDCC

SHEET:

March 17, 2017

.

REVISED:

.

.

Tallahassee, Florida

DATE:

RICKARDS HIGH SCHOOL

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL LIGHTING

SHEET TITLE:

LEON COUNTY SCHOOLS

JOB NUMBER:1640

DRAWN BY:DESIGNED BY:

100% CONSTRUCTION DOCUMENTS

SUBMITTAL:

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

NOTES

Charles K. Fleming, PE #48107

CONTROLS REPLACEMENT

BUILDING 20

LEO COU TY SCHOOLSn n

E4.3

ELECTRICALAUDITORIUM STAGE LIGHTINGSYSTEM DETAILS

CKF TEB

Page 8: RICKARDS HIGH SCHOOL AUDITORIUM THEATRICAL LIGHTING ...€¦ · auditorium e1.1 electrical legend and notes e2.1 auditorium demolition plan e3.1 auditorium new work plan e4.1 auditorium

SIDE VIEW REAR VIEWFRONT VIEW

(BACK BOX REMOVED)

3.) BACK BOX SHALL BE SINGLE GANG 2.50" DEEP RACO #690(OR EQUIVALENT) AND IS SUPPLIED BY OTHERS.

2.80

4.50

DMX 1 OUTPUT

NOTES:

1.) FACE PANEL IS A CREAM ABS INJECTION-MOLDED PLASTIC.

3.28

1.352.50.39

ELECTRICAL DIAGRAM

3.75

2.) ALL NOMENCLATURE IS LASER MARKED WITH A CONTRASTING COLOR.

SHIELD

~~

RED

BLK

~

5

7

8

6

3

4

2

C1

DATA 2 +

DATA 2 -

DATA 1 +

DATA 1 -

5

4

3

2

TERMINAL STRIP

(1) BELDEN #9729 CABLE

1

(BY OTHERS)

COMMON1

2002 ETC, INC.

ASSEMBLY

I.D. LABEL

5 642 31

J3 DMX512

7 8

1086B4045 REV.B

C1

8 7

DMX512

56 4 3

MADE IN U.S.A.

J2

2 1

PUSH

ELECTRICAL DIAGRAM

SIDE VIEWFRONT VIEW

1.38

4.503.28

1.81

4.56

.61

.08 2.50

3.75

REAR VIEW

(BACK BOX AND WIRE CONNECTORS REMOVED)

1.) FACE PANEL IS .08 ALUMINUM FINISHED INA BLACK FINE-TEXTURED POWDER COAT.

AND IS SUPPLIED BY OTHERS.

RACO #691 (OR EQUIVALENT),3.) BACK BOX SHALL BE DOUBLE GANG 2.50" DEEP

NOTES:

C2C1

DMX 2 INPUTDMX 1 INPUT

DMX512

DMX512

J3

1 32 4

I.D. LABEL

ASSEMBLY

8 7 6 5

MADE IN U.S.A.

1086B4044 REV.B

865 7

2002 ETC, INC.

C1

J2

34 2 1

C1C2

SHIELD

~~

RED

BLK

~

5

7

8

6

3

4

2

C1

DATA 2 +

DATA 2 -

DATA 1 +

DATA 1 -

5

4

3

2

TERMINAL STRIP

(1) BELDEN #9729 CABLE

1

(BY OTHERS)

COMMON1

(TYP. TOP & BOTTOM)

.05 X 45° BEVEL

~~~

DATA 1 -

DATA 1 +

DATA 2 -

DATA 2 +

8

7

6

5

RED

SHIELD

BLK

4

3

2

1

5

C2

4

3

2

1COMMON

(1) BELDEN #9729 CABLE

TERMINAL STRIP

(BY OTHERS)

2002 ETC, INC.

1086B4044 REV.B

ASSEMBLY

I.D. LABEL

DMX512

1 2 3 4

J3

5 6 7 8

DMX512

8 67 5

MADE IN U.S.A.

C1

J2

4 3 2 1

GANGABLE BACK BOX IS NOT ACCEPTABLE.

2.) ALL NOMENCLATURE IS ENGRAVED IN WHITE.

JDMX

SYMBOL:

JDMX2

SYMBOL:

SHEET:

March 17, 2017

.

REVISED:

.

.

Tallahassee, Florida

DATE:

RICKARDS HIGH SCHOOL

M Ginniss & Fleming

Mechanical Electrical Fire Protection Plumbing

Engineering, Inc.c

AUDITORIUM THEATRICAL LIGHTING

SHEET TITLE:

LEON COUNTY SCHOOLS

JOB NUMBER:1640

DRAWN BY:DESIGNED BY:

100% CONSTRUCTION DOCUMENTS

SUBMITTAL:

Tallahassee, Florida 323081401 Miccosukee Road - Suite 200

EB #05990

NOTES

Charles K. Fleming, PE #48107

CONTROLS REPLACEMENT

BUILDING 20

LEO COU TY SCHOOLSn n

E4.4

ELECTRICALAUDITORIUM STAGE LIGHTINGSYSTEM DETAILS

CKF TEB