Thermal Ground Floor insulaTion
For help choosing the right product for your project please contact Thermal Economics
Technical Department on 01582 544255
For all our Acoustic & Thermal insulation products visit: www.thermal-economics.co.uk
Building Regulations require new build floors to achievethe following area weighted averages:
Approved Doc. Part L 2013 (England) - 0.25W/m2K
Technical Handbook Section 6 2015 (Scotland) - 0.18W/m2K
Approved Doc. Part L 2014 (Wales) - 0.18W/m2 K
BBA Certified insulation foruse in concrete floors.
Used by major UK Housebuilders with around 5million sq. metres beingsuccessfully installed.
EPS is Non Hygroscopic sodoes not absorb water fromthe ground.
Environmentally friendly:No CFC's or HCFC's usedin production.
ODP = ZeroGWP = Less than 5
u-Value examples -Concrete slab
Thermal Economics
Platinum Ground Floor
Insulation provides an
extremely cost effective
alternative to PUR & PIR
insulation boards with
equivalent thermal
performance.
Floor Build-up:
65mm Screed.
TE PlatinumGround FloorInsulation as listed.
Insitu Slab.
Te Platinum Ground Floor insulation
a cost effective solution for Part l 2013
& section 6 2015 compliance
Perimeter / Area Ratio
Insu
latio
n Th
ickn
ess
(mm
)
0.11 0.15 0.17 0.19 0.20 0.21 0.21 0.22 0.22 0.10 0.13 0.15 0.16 0.17 0.17 0.18 0.18 0.18 0.09 0.12 0.13 0.14 0.15 0.15 0.16 0.16 0.16 0.08 0.10 0.11 0.12 0.12 0.12 0.12 0.13 0.13 0.07 0.08 0.09 0.10 0.10 0.10 0.10 0.10 0.11
Meets minimum requirement of Approved Doc. Part L 2013 (England) only.
Meets minimum requirements of all building regulations across the UK.
IN
SI
TU
C
ON
CR
ET
E
FL
OO
RS
Building Regulations require new build floors to achievethe following area weighted averages:
Approved Doc. Part L 2013 (England) - 0.25W/m2K
Technical Handbook Section 6 2015 (Scotland) - 0.18W/m2K
Approved Doc. Part L 2014 (Wales) - 0.18W/m2 K
BBA Certified insulationfor use in beam & blockfloors.
Used by major UK Housebuilders with around 5million sq. metres beingsuccessfully installed.
EPS is Non Hygroscopicso does not absorb waterfrom the ground.
Environmentally friendly:No CFC's or HCFC's usedin production.
ODP = ZeroGWP = Less than 5
a cost effective solution for Part l 2013
& section 6 2015 compliance.
Thermal Economics
Platinum Ground Floor
Insulation provides an
extremely cost effective
alternative to PUR & PIR
insulation boards with
equivalent thermal
performance.
Te Platinum Ground Floor insulation
u-Value examples - Beam & Block
Floor Build-up:
65mm Screed.
TE Platinum GroundFloor Insulation aslisted.
150mm Beams with100mm Blocks(K-value =0.15).
Meets minimum requirement of Approved Doc. Part L 2013 (England) only.
Meets minimum requirements of all building regulations across the UK.
ST
AN
DA
RD
B
EA
M
&
BL
OC
K
FL
OO
RS
Simple insulation edgestrips can help to preventCold Bridging aroundground floor perimeters.
Without edge insulation With edge insulation
Using an insulation edgestrip is a very simple wayto prevent a cold bridgethrough the wall / floorjunction. However, a recentstudy by the Zero CarbonHub found that edgeinsulation strips areomitted from many sitesacross the UK.
Thermal Economics canprovide PSi calculations todetail the thickness of edge
insulation required or you can simply work to one of ourtried and tested solutions. Edge strips are available instandard sizes or can be supplied in site specific sizes.
Ground Floors - aVoidinG Thermal BridGinG
For help with cold bridging issues please contact Thermal Economics
Technical Department on 01582 544255
Where edgeinsulation isomitted thetemperature ofinternal surfacescan drop to allowcondensation toform.
Heat flux showsthat heat 'leaks'through the un-insulated floor /wall junction.
When edgeinsulation is usedthe temperature ofinternal surfaces iskept high enoughto preventcondensation.
The edgeinsulationprevents theheat lossthrough thefloor / walljunction.
TH
ER
MA
L
EC
ON
OM
IC
S
ED
GE
I
NS
UL
AT
IO
N
Thermal economics edge insulation
Approved Docs. Part L (England & Wales) and Technical
Handbook Section 6 (Scotland) require refurbished floors to
achieve a maximum U-value of 0.70W/m2K and an area
weighted average of 0.25W/m2K.
BBA Certified insulation foruse in floating floors.
Provides significantsavings over PUR/PIR.
EPS is Non Hygroscopic sodoes not absorb water fromthe ground.
Environmentally friendly:No CFC's or HCFC's usedin production.
ODP = ZeroGWP = Less than 5
u-Value examples
Thermal Economics
Platinum Ground Floor
Insulation provides an
extremely cost effective
alternative to PUR & PIR
insulation boards with
equivalent thermal
performance.
Floor Build-up:
22mm Chipboard.
Insulation as listedbetween battens.
Existing slab.
Floor Build-up:
22mm Chipboard.Insulation as listed.
Existing slab.
Te Platinum Ground Floor insulation
a cost effective solution forconcrete floor refurbishment.
Meets the area weighted average requirements of all refurbishment building regulations across the UK.
FL
OA
TI
NG
/
E
XI
ST
IN
G
FL
OO
RS
Perimeter / Area Ratio
Meets minimum requirement of Approved Doc. Part L 2013 (England) only.
Meets minimum requirements of all building regulations across the UK.
Blo
ck S
ize
(mm
)
0.11 0.13 0.14 0.15 0.15 0.16 0.16 0.16 0.160.10 0.11 0.12 0.13 0.13 0.13 0.13 0.14 0.140.08 0.09 0.10 0.10 0.10 0.10 0.10 0.10 0.10
Perimeter / Area Ratio
Blo
ck S
ize
(mm
)
0.11 0.13 0.14 0.15 0.15 0.15 0.16 0.16 0.160.10 0.12 0.12 0.13 0.13 0.14 0.14 0.14 0.140.08 0.09 0.10 0.10 0.10 0.10 0.11 0.11 0.11
high Performance insulated suspended floorsystem to achieve extremely low u-values
u-Value examples -Beam & Block
The Platinum
Beamshield Plus system
provides a simple and
cost effective way to
achieve very low ground
floor U-values making it
ideal for Part L 2013 and
Section 6 2015
compliance.
Building Regulations require new build floors to achievethe following area weighted averages:
Approved Doc. Part L 2013 (England) - 0.25W/m2K
Technical Handbook Section 6 2015 (Scotland) - 0.18W/m2K
Approved Doc. Part L 2014 (Wales) - 0.18W/m2 K
All calculationsassume beams ata ratio of 4 to 1 atnominal 600mmand nominal300mm centres.
Other block sizesare available toachieve therequired U-value.
Starter unit Half unit End unitFull unit
Platinum Beamshield Plus
BBA Certified System
U-Values as low as0.08W/m2K achievable
Complete solution withwhole floor coverageincluding insulatedperimeter details
Simple and quickinstallation
Insulation/formwork in one
ODP = ZeroGWP = Less than 5
150mm x 94mm Beam
175mm x 106mm Beam
BE
AM
&
I
NS
UL
AT
ED
B
LO
CK
F
LO
OR
S
Approved Docs. Part L (England & Wales) and Technical
Handbook Section 6 (Scotland) require refurbished floors to
achieve a maximum U-value of 0.70W/m2K and an area
weighted average of 0.25W/m2K.
Extremely cost effectivesolution.
Clean alternative to MineralWool products.
Allows floor timber tobreathe.
Simple to install.
Reduces air movementthrough the floor.
Environmentally friendly:No CFC's or HCFC's usedin production.
ODP = ZeroGWP = Less than 5
high Performance micro Perforated low einsulation membrane for refurbishment projects.
Floortherm MP is a micro
perforated insulating
membrane, allowing floor
timbers to breathe.
It's low emissive surfaces
reflect radiant heat and
provide excellent thermal
performance.
Floor Build-up:
22mm Chipboard.
Unventilated Cavityas listed.
Floortherm MP.
Ventilated Void.
Floor Build-up:
22mm Chipboard.
Unventilated Cavityas listed.
Floortherm MP.
Unventilated Cavityas listed.
Floortherm MP.
Ventilated Void.
Floortherm mP
u-Value examples
Meets the area weighted average requirements of all refurbishment building regulations across the UK.
TI
MB
ER
F
LO
OR
S
CSH
Thermal SolutionsF
L O
O R
Technical Services
CA
LC
UL
AT
IO
NS
DE
SI
GN
A
DV
IC
E
Thermal Economics highly qualifiedand experienced Technical Departmentcan provide a range of calculationsand assessments including:SAP CalculationsPSi AssessmentsCondensation CalculationsU-value Calculations
Energy Performance Certificates / BREEAM Assessments
We can design cost effective solutions thatmeet your needs and comply with the latestbuilding regulations.We can also help to provide bespoke, highperformance solutions for planningrequirements, CSH/BREEAM credits orto overcome project specific issues.We have recently saved a house builder over£1000 per dwelling, by simply revising thethermal insulations being used. This equatesto a £75,000 saving across the site.
Acoustic Solutions
ULTRATHERMALREFLEX
RAFTERALREFLEX
THERM
PlatformfloorIsosonic
IsorubberBase
IsorubberTop
IsosonicTimberlfoor
IsorubberHP3
6mm thick acousticmatting for usebelow screeds ortimber floorfinishes.
Robust Details:E-FC-4E-FC-14
C O
N C
R E
T E
F
L O
O R
S
T I M
B E
R
F L
O O
R S
U F
H
3mm thick acousticoverlay for useover concrete ortimber floors.
Robust Details:E-FC-9E-FC-10
Acoustic system fortimber floorconstructions.
Suitable for new buildor refurb projects.
Part E compliant
25mm thick acousticdeck. Comprising 18mmT&G chipboard and a7mm acoustic layer.
Suitable for use in newbuild and refurb projects.
Robust Detail: FFT5
3mm thick acoustic mattingfor use below screeds ortimber floor finishes.
Ideal for use with all typesof under floor heatingsystem.
Robust Detail: E-FC-12
VIN
YL
UN
DE
RLA
Y IsorubberTop
Suitable for use below alltypes of vinyl floor finishincluding:TilesPlanksSheetsIndependently testedfor wear and lifting.
T I
M B
E R
F
R A
M E
R O
O F
SW
A L
L SThe only spun bond,
Class W1 insulatingBreather membraneavailable in the UK.Designed to improveU-values withoutincreasing structurethickness.
Vapour permeable,insulating membrane.Designed to improveU-values withoutincreasing structurethickness.Ideal for Section 62015 compliance.
High performance,BBA certified cavity wallinsulation and rain barrier.Designed for achievingvery low wall U-values.Ideal for use where thestructure thickness needsto be kept to a minimum.
Cost effective, LABCapproved pitched roofinsulation system.Designed for use in non-ventilated roof structures.
M A
S O
N R
Y
W A
L L
S
High performance,BBA certified cavitywall insulation andrain water barrier.Used by majorhouse buildersacross the UK.
Extremely costeffective, dry lininginsulation systemfor refurbishmentapplications.
For help choosing the right product for your project please contact Thermal Economics
Technical Department on 01582 544255
For all our Acoustic & Thermal insulation products visit: www.thermal-economics.co.uk
ISO 14001Environmental
T:
F:
E:
W:
01582 450814
01582 429305
www.thermal-economics.co.uk©Thermal Economics Ltd. Issue 1 September 2016