![Page 1: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/1.jpg)
THE THE USE OF THE NATURAL USE OF THE NATURAL CIRCULATION FLOW MAPCIRCULATION FLOW MAP
F. D’Auria, D. Araneo, B. Neykov – Lecture T20
DIPARTIMENTO DI INGEGNERIA MECCANICA, NUCLEARE E DELLA PRODUZIONE
UNIVERSITA' DI PISA56100 PISA -ITALY
IAEA & ICTP Course onIAEA & ICTP Course on
NATURAL CIRCULATION IN WATER-COOLED NATURAL CIRCULATION IN WATER-COOLED NUCLEAR POWER PLANTSNUCLEAR POWER PLANTS
Trieste, Italy, June 25-29 2007 Trieste, Italy, June 25-29 2007
![Page 2: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/2.jpg)
2/61
Local Transport Phenomena & Models
• LOCAL MASS, MOMENTUM AND ENERGY TRANSPORT PHENOMENA
• PREDICTIVE MODELS & CORRELATIONS
Natural Circulation Experiments
• INTEGRAL SYSTEM TESTS • SEPARATE EFFECTS TESTS • TEST FACILITY SCALING METHODS
Integral System Phenomena & Models
• SYSTEM MASS, MOMENTUM AND ENERGY TRANSPORT PHENOMENA
• N/C STABILITY • STABILITY ANALYSIS TOOLS • PASSIVE SAFETY SYSTEM DESIGN
Reliability & Advanced Computational Methods
Experiments • PASSIVE SYSTEM RELIABILITY • CFD FOR NATURAL CIRCULATION
FLOWS
Introduction
• GLOBAL NUCLEAR POWER • ROLE OF N/C IN ADVANCE DESIGNS • ADVANTAGES & CHALLENGES
Opening Session
• INTRODUCTIONS • ADMINISTRATION • COURSE ROADMAP
Local Transport Phenomena & Models
• LOCAL MASS, MOMENTUM AND ENERGY TRANSPORT PHENOMENA
• PREDICTIVE MODELS & CORRELATIONS
Natural Circulation Experiments
• INTEGRAL SYSTEM TESTS • SEPARATE EFFECTS TESTS • TEST FACILITY SCALING METHODS
Integral System Phenomena & Models
• SYSTEM MASS, MOMENTUM AND ENERGY TRANSPORT PHENOMENA
• N/C STABILITY • STABILITY ANALYSIS TOOLS • PASSIVE SAFETY SYSTEM DESIGN
Reliability & Advanced Computational Methods
Experiments • PASSIVE SYSTEM RELIABILITY • CFD FOR NATURAL CIRCULATION
FLOWS
Introduction
• GLOBAL NUCLEAR POWER • ROLE OF N/C IN ADVANCE DESIGNS • ADVANTAGES & CHALLENGES
Opening Session
• INTRODUCTIONS • ADMINISTRATION • COURSE ROADMAP
Roadmap for the Training Course Roadmap for the Training Course on NC in Water-Cooled Reactorson NC in Water-Cooled Reactors
![Page 3: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/3.jpg)
CONTENTCONTENT
2/47
NCFM DEFINITION AND ROLENCFM DEFINITION AND ROLE
(CONNECTION WITH) THE SCALING ISSUE(CONNECTION WITH) THE SCALING ISSUE
DERIVATION OF THE NCFM (part of scaling activity)DERIVATION OF THE NCFM (part of scaling activity) - - The ITFThe ITF - - The NC BICThe NC BIC - The experimental scenario- The experimental scenario - - The scalThe scalee dependent parameters dependent parameters - The capability of the codes in predicting NC- The capability of the codes in predicting NC - The scale-up of data: - The scale-up of data: 1 NC, use of TH codes, NC regimes NC, use of TH codes, NC regimes - The NCFM - The NCFM
APPLICATION OF THE NCFMAPPLICATION OF THE NCFM
CONCLUSION CONCLUSION
APPENDIX 1: MAX POWER REMOVAL BY NCAPPENDIX 1: MAX POWER REMOVAL BY NC
![Page 4: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/4.jpg)
THE NCFM DEFINITION AND ROLETHE NCFM DEFINITION AND ROLE
2/47
THE NCFM ACRONYM:THE NCFM ACRONYM:
NATURAL CIRCULATION FLOW MAP FOR PWR SYSTEMS
WHAT IS NCFM?WHAT IS NCFM?
NCFM IS AN ‘ENGINEERING’ TOOL DERIVED FROM ITF MEASURED DATA FOR 1 AND 2 NATURAL CIRCULATION
THE NCFM ROLETHE NCFM ROLE:
IT CAN BE USED TO SUPPORT:• SCALING STUDIES (but also derived from scaling related data)• DESIGN/OPTIMISATION OF NC SYSTEMS• VALIDATION OF COMPUTATIONAL MODELS (codes, nodalisation, etc.)• JUDGING THE NC PERFORMANCE
![Page 5: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/5.jpg)
The framework:The framework:THE TRANSIENT PERFORMANCE OF LWR NPP (HIGH POWER, HIGH PRESSURE, LARGE GEOMETRY)
The origin of the problem:The origin of the problem:THE IMPOSSIBILITY TO PERFORM RELEVANT
EXPERIMENTS AT FULL SCALE (POWER, PRESSURE, GEOMETRY)
THE SCALING ISSUETHE SCALING ISSUE
5/61
![Page 6: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/6.jpg)
The goal of a scaling analysisThe goal of a scaling analysis
TO ENSURE (OR TO SUPPORT) THE PREDICTABILITY OF LWR NPP TRANSIENT SCENARIOS
The historical ways to address the issueThe historical ways to address the issue
FLUID BALANCE EQUATIONS (deriving non-dimensional parameters)
SEMI-EMPIRICAL MECHANISTIC EQUATIONS (deriving non-dimensional parameters)
TO PERFORM EXPERIMENTS (at different scales)
TO DEVELOP, TO QUALIFY, TO APPLY CODES (by showing capabilities at different scales)
6/61
THE SCALING ISSUETHE SCALING ISSUE
![Page 7: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/7.jpg)
The target of a scaling analysisThe target of a scaling analysis
THE GLOBAL SYSTEM PERFORMANCE (e.g. the prediction of pressure behavior during blow-down, following LOCA)
THE PERFORMANCE OF A COMPONENT OR OF A ZONE OF THE SYSTEM (e.g. pump performance during LBLOCA, or CL-DC mixing following ECCS injection)
THE ‘LOCAL’ EVOLUTION OF THERMALHYDRAULIC PHENOMENA (e.g. the CHF occurrence in fuel rods, the CCFL at the UTP following UP injection, the TPCF at the break)
7/61
MACROSCALEMACROSCALE
COMPONENT SCALECOMPONENT SCALE
MICROSCALEMICROSCALE
THE SCALING ISSUETHE SCALING ISSUE
![Page 8: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/8.jpg)
The objectives of a scaling analysisThe objectives of a scaling analysis
TO PROVE THE CAPABILITY IN SIMULATING AN ASSIGNED PHENOMENON
TO DESIGN A TEST FACILITY
TO PROVE THE SCALING CAPABILITY OF A TH MODEL OR OF A TH (SYSTEM) CODE
8/61
THE SCALING ISSUETHE SCALING ISSUE
![Page 9: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/9.jpg)
A SPECIAL ISSUE OF THE J. ‘NUCLEAR ENGINEERING AND DESIGN’ DEVOTED TO SCALING IN 1998 – MORE THAN 300 PAGES & 12 PAPERS
9/61
THREE LEVELS OF SCALING ANALYSIS PROPOSED BY ISHII et al.:THREE LEVELS OF SCALING ANALYSIS PROPOSED BY ISHII et al.:
- Integral scaling- Integral scaling
- Control volume scaling- Control volume scaling
- Local phenomena scaling- Local phenomena scaling
THE AUTHORS END UP WITH MORE THAN 200 SCALING FACTORS, BUTTHE AUTHORS END UP WITH MORE THAN 200 SCALING FACTORS, BUT
“… The design cannot completely satisfy all the scaling requirements. thus, scaling distortions are inevitable … Distortions are encountered for two major reasons:
- difficulty to match the local scaling criteria
- lack of understanding of the local phenomenon itself.”
THE SCALING ISSUETHE SCALING ISSUE
![Page 10: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/10.jpg)
10/61
A SCALING STUDY WAS COMPLETED BY BANERJEE et al., FOCUSED ON A SCALING STUDY WAS COMPLETED BY BANERJEE et al., FOCUSED ON THE THE ROSAROSA, , SPESSPES AND AND OSU OSU FACILITIES, THAT SIMULATE THE FACILITIES, THAT SIMULATE THE AP-600 AP-600 NPPNPP. ABOUT 30 SCALING PARAMETERS WERE FOUND. AN EXCERPT . ABOUT 30 SCALING PARAMETERS WERE FOUND. AN EXCERPT FROM A LARGER TABLE IS GIVEN.FROM A LARGER TABLE IS GIVEN.
The scaling study identified phenomena in general agreement with the PIRT. Notwithstanding the differences in the table, “…the magnitude of the non-dimensional coefficients were similar for the ITF and the AP-600 … the same ‘important’ processes occurred in the ITF as might be expected in the AP-600.”
A SPECIAL ISSUE OF THE J. ‘NUCLEAR ENGINEERING AND DESIGN’ DEVOTED TO SCALING IN 1998 – MORE THAN 300 PAGES & 12 PAPERS
THE SCALING ISSUETHE SCALING ISSUE
![Page 11: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/11.jpg)
A) PURSUING A SYSTEMATIC APPROACH IMPLIES
1) ID and characterization of thermal-hydraulic phenomena
2) Writing equations (fluid balance & mechanistic) at macro-scale, component-scale and micro-scale levels and deriving suitable non-dimensional parameters
3) Achieving ‘qualified’ functional relationships between phenomena and scale
B) SCALING APPROACHES AVAILABLE (Zuber, Ishii, etc.)
C) COMPREHENSIVE SOLUTION NOT ACHIEVED YET (Ishii et al., J. NED 1998, see also below)
11/61
THE SCALING ISSUETHE SCALING ISSUE
![Page 12: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/12.jpg)
D) IN GENERAL TERMS: two-phase, transient TH phenomena, are affected by local system parameters that do not appear into balance equations or into ‘scalable’ mechanistic models:
12/61
TPCF is affected (at least) by phenomena like ‘vapor pull through’ & sub-cooled vapor formation by ‘sharp edge cavitation’. These are not reproducible at a different scale. In addition, heat losses, mixture levelformation and fluid temperature stratification cannot be scaled up.
THE SCALING ISSUETHE SCALING ISSUE
![Page 13: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/13.jpg)
13/61
E) THE ATTEMPT TO SCALE UP ALL TH PHENOMENA (e.g. TPCF, CCFL, nat. circ., CHF, DPi, ) RELEVANT DURING AN ASSIGNED TRANSIENT IN LWR NPP, IS UNSUCCESSFUL:
A myriad scaling factors
Counterfeiting values
THEREFORE,
• HIERARCHY IN SCALING FACTORS (as recognized by Zuber)
• AN OVERALL SCALING STRATEGY
ARE NEEDED
THE SCALING ISSUETHE SCALING ISSUE
![Page 14: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/14.jpg)
14/61
DERIVATION OF THE NCFM / THE ITFDERIVATION OF THE NCFM / THE ITF
THE ITF (AND THE NPP) AT THE ORIGIN OF THE NC DATABASE
![Page 15: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/15.jpg)
15/61
DERIVATION OF THE NCFM / THE ITFDERIVATION OF THE NCFM / THE ITFA MORE DETAILED VIEW OF A SINGLE ITF: THE LOBI/MOD2
![Page 16: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/16.jpg)
16/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE NC BIC THE NC BIC
HARDWARE CHARACTERISTICS OF SELECTED ITF AND DOEL NPP
![Page 17: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/17.jpg)
17/61
DERIVATION OF THE NCFM / DERIVATION OF THE NCFM / THE NC BICTHE NC BIC
BIC VALUES FOR SELECTED ITF EXPERIMENTS – 1 OF 2
![Page 18: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/18.jpg)
18/61
DERIVATION OF THE NCFM / DERIVATION OF THE NCFM / THE NC BICTHE NC BIC
BIC VALUES FOR SELECTED ITF EXPERIMENTS – 2 OF 2
Quantities defined in previous slide; Including DOEL NPP
![Page 19: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/19.jpg)
19/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE EXP SCENARIOTHE EXP SCENARIO
THE NC SCENARIO FROM DRAINING PS MASS INVENTORY – 1 of 2
1) Core Flowrate; 2) Mass Inventory and Rod Surface Temperature; 3) DP oscillations; 4) Primary Pressure and SG DP
1
2
3
4
![Page 20: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/20.jpg)
20/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE EXP SCENARIOTHE EXP SCENARIO
THE NC SCENARIO FROM DRAINING PS MASS INVENTORY – 2 of 2
5) Density in HL; 6) Fluid velocities in IL and BL
5
6
![Page 21: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/21.jpg)
21/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE SCALE DEPENDENCETHE SCALE DEPENDENCE
THE PARAMETERS TO BE CONSIDERED IN SCALING
1) & 2) PS volume; 3) Thermal load on individual U-Tubes (various L/D); 4) PS pressure
12
3
4
KvKv5 KvKv5
pp
Kw/UTKw/UT5
![Page 22: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/22.jpg)
22/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE SCALE DEPENDENCETHE SCALE DEPENDENCE
THE PARAMETERS THAT HAVE SMALL SCALE EFFECT
1) Length over diameter in HL; 2) Core power; 3) Presence of core bypass;4) Core active height
1
2
3
4
![Page 23: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/23.jpg)
23/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE CODE CAPABILITIESTHE CODE CAPABILITIES
THE TH SYS CODES ARE CAPABLE TO PREDICT RELEVANT NC PARAMETERS – TYPICAL NODALISATION SKETCH
![Page 24: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/24.jpg)
24/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE CODE CAPABILITIESTHE CODE CAPABILITIES
THE TH SYS CODES ARE CAPABLE TO PREDICT RELEVANT NC PARAMETERS – EXP/CALC BIC DATASET
![Page 25: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/25.jpg)
25/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE CODE CAPABILITIESTHE CODE CAPABILITIES
THE TH SYS CODES ARE CAPABLE TO PREDICT RELEVANT NC PARAMETERS – NODALISATION RESOURCES
![Page 26: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/26.jpg)
26/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE CODE CAPABILITIESTHE CODE CAPABILITIES
THE TH SYS CODES ARE CAPABLE TO PREDICT RELEVANT NC PARAMETERS
1) Initial steady-state (fluid temperature vs length); 2) Density in HL vs time; 3) DP across SG UT in PS vs time; 4) Core flowrate vs PS mass inventory.
1
2
3
4
![Page 27: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/27.jpg)
27/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE ATTEMPT TO SCALE-UPTHE ATTEMPT TO SCALE-UP
A SIMPLIFIED APPROACH TO SCALE-UP 1 NC
Starting from the definition of driving and resistant forces (eqs. 1), one obtains an expression for core flowrate, eq. 4, that depends upon KvKv and pressure drops(distributed and localized as given by the eq. 3 and the C6 coefficient in eq. 4).
1
2
3
4
![Page 28: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/28.jpg)
11/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE ATTEMPT TO SCALE-UPTHE ATTEMPT TO SCALE-UP
A SIMPLIFIED APPROACH TO SCALE-UP 1 NC: RESULTS
A core flowrate, function of Kv is derived (1 NC) and is compared with exp data & with results of code calculations.
![Page 29: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/29.jpg)
29/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE ATTEMPT TO SCALE-UPTHE ATTEMPT TO SCALE-UP
A SIMPLIFIED APPROACH TO SCALE-UP 2 NC: RESULTS
The attempt to scale-up 2 NC is not as succesfull: a) “extrapolation” formulas cannot be easily derived; b) the application of qualified code-nodalisation producesthe results shown in the figures.
![Page 30: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/30.jpg)
30/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE NC REGIMESTHE NC REGIMES
THE (SCALE INDEPENDENT) NC REGIMES
1 NC, 2 NC and max 2 NC, 2 NC instabilities (siphon condensation),reflux condensation, dryout occurrence can be distinguished in the figure,items 1 to 5
1 2 3 4 5
![Page 31: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/31.jpg)
31/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE NCFM THE NCFM
THE ROUGH DATA GATHERING (TO DERIVE NCFM)
Collecting of rough ITF data does not provide suitable information
![Page 32: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/32.jpg)
32/61
DERIVATION OF THE NCFM /DERIVATION OF THE NCFM / THE NCFM THE NCFM
THE DATA BASE HAS BEEN REPORTED IN THE “G/P VS RM/V” PLANE
The bounding of the database constitutes the NCFM. This is used for • scaling studies• design/optimisation of nc systems• validation of computational models (codes, nodalisation, etc.)• judging the NC performance
RM/V (kg/m3)
200300400500600700800900
G/P
(kg
/MW
s)
0
5
10
15
20
25
Bethsy 2%Bethsy 5%LobiLstf 2%Lstf 5%SemiscalePkl 2%Pkl 3%Spes 1 %Spes 5 %
RM/V (kg/m3)
200300400500600700800900G
/P (k
g/M
Ws)
0
5
10
15
20
25
NCFMNCFM
![Page 33: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/33.jpg)
33/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
Characteristics of NPP considered for the application of the NCFM
1PWR
2PWR
3PWR
4VVER
5EPR
6AP-600
7EP-1000
Nominal Power (MW) 1877 870 2733 3000 4250 1972 2958Primary System volume (m3) 167 150 330 359 459 211 339
SG type U-Tubes U-Tubes Once-Through Horizontal U-Tubes U-Tubes U-Tubes
No. of loops 2 4 2 4 4 2 3
No. of pumps 2 4 4 4 4 4 6
Nominal mass inventory (Mg) 108 108 224 240 307 145 227
Nominal Core Flow (Kg/s) 9037 3150 17138 15281 20713 8264 14507
Pressurizer and SG pressure (MPa)
15.66.
14.03.1
15.06.4
15.76.3
15.57.2
15.55.5
15.86.4
![Page 34: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/34.jpg)
34/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
Characteristics of ITF considered for the application of the NCFM
Pactel
(original) Pactel
(with CMT) ° RD14M
Reference reactor and power (MW) WWER-440 1375
WWER-440 1375
CANDU 1800
No. of rods 144 144 70 No. of SG 3 3 2 SG type Horizontal Horizontal U-Tubes Actual Kv + 1/433 1/462 1/378
![Page 35: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/35.jpg)
35/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
RESULT – 1 OF 3
RM/V (kg/m3)
200300400500600700800900
G/P
(kg/M
Ws)
0
5
10
15
20
25
30
35
WWERPWR-3EPRPWR-2
The predicted NC performance of VVER-1000, PWR-NPP 2 and EPR is consistent with the derived NCFM. ‘Lower’ NCP for PWR-NPP 3.
![Page 36: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/36.jpg)
36/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
RESULT – 2 OF 3
The predicted NC performance of EP-1000, PWR-NPP 1 and AP-600 is consistent with the derived NCFM
RM/V (kg/m3)
200300400500600700800900
G/P
(kg
/MW
s)
0
5
10
15
20
25
PWR - 1EP-1000
AP-600
![Page 37: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/37.jpg)
11/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
RESULT – 3 OF 3
Suitable NC performance is obtained for VVER-440 simulator and not for CANDU simulator
![Page 38: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/38.jpg)
11/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
SUMMARY OF RESULT
Evaluation of NCP shall be considered together with quality of the available DB and of the adopted computational tools
NPP or ITF Quality of
starting DB
Quality of adopted
tools
Evaluation of
NCP PWR-1 Y Y S PWR-2 N Y S PWR-3 Y Y NS WWER-1000 Y Y S EPR N Y S AP-600 Y Y S EP-1000 N N - Pactel Y - S Pactel with CMT
Y - S
RD14M N.A. - - Y Confirmed N Not Confirmed N.A. Not Available - Not applicable S Suitable (for NCP) NS Not Suitable
![Page 39: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/39.jpg)
39/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM ATUCHA-1 PHWR – Ferreri et al. - Nodalisation for SET II
![Page 40: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/40.jpg)
40/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
ATUCHA-1, Ferreri et al.
Outline of performed calculations – NPP qualified Relap5 input deck is usedto evaluate the NCP of the CNA-1
# RUN Power MW to Primary
MOD-UP open
MOD line volumes
PRZ closes
NOTES
1 Test26 5% - 59.1 No No Yes 2 Test27 4% - 47.3 No No Yes 3 Test28 3% - 36.1 No No Yes 4 Test30 2% - No No Yes 5 Test31 3% - Yes No Yes
SET-I
6 Test35 3% - Yes Yes Yes SET-II 7 Test01-N 3% - Yes Yes No NA-S.A. SET-III 8 Test36 5% - 55.5 Yes Yes Yes 9 Test33 4% - 47.3 Yes No Yes 10 Test34 3% - 35.9 Yes Yes Yes
SET-II
11 Test02-N 4% - 47.0 Yes Yes No 12 Test03-N 5% - 58.9 Yes Yes No
NA-S.A. SET-III
13 Test04-N 3% - 35.9 Yes Yes No SBLOCA
SET-III
![Page 41: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/41.jpg)
11/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
ATUCHA-1 PHWR, Ferreri et al.
Results from SET-I
![Page 42: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/42.jpg)
11/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
ATUCHA-1 PHWR, Ferreri et al.
Results from SET-II
![Page 43: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/43.jpg)
11/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
ATUCHA-1 PHWR, Ferreri et al.
Results from SET-III
![Page 44: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/44.jpg)
11/61
APPLICATION OF THE NCFM APPLICATION OF THE NCFM
PKL III experiment F1.2. Del Nevo et al. (2006)
Natural circulation maps
0
5
10
15
20
25
01002003004005006007008009001000
RM/V [Kg/m^3]
G/P
[Kg/
MW
s]
Experimental Data
![Page 45: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/45.jpg)
11/61
APPLICATION OF THE NCFM – BWR NC DATABASEAPPLICATION OF THE NCFM – BWR NC DATABASE
11/24
DATABASE FROM: NPP measurements (N), ITF (I) & Calculations (C)
N
I
N
N
N
N
C
C
C
C
C
45/61
![Page 46: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/46.jpg)
APPLICATION OF THE NCFM – BWRAPPLICATION OF THE NCFM – BWR
11/24
BWR NPP DATA & RBMK qualified calculation
NCNC
46/61
![Page 47: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/47.jpg)
47/61
REVISITED REVISITED RD-14mRD-14m APPLICATION ( APPLICATION (CANDUCANDU RELATED) RELATED)
Step 0: Development of Relap5 RD-14m nodalisation
1636 hydraulic nodes
11788 meshes for conduction heat transfer
![Page 48: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/48.jpg)
17/24
REVISITED REVISITED RD-14mRD-14m APPLICATION ( APPLICATION (CANDUCANDU RELATED) RELATED)
Step 1: Analysis of LBLOCA test B-9401 (IAEA framework)
Rod surface temperaturePCT location
System (header 6)pressure
48/61
![Page 49: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/49.jpg)
11/24
REVISITED REVISITED RD-14mRD-14m APPLICATION ( APPLICATION (CANDUCANDU RELATED) RELATED)
Step 2: full demonstration of nodalization qualification
“Steady-state”level
“On-Transient”Level (by FFTBM)
![Page 50: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/50.jpg)
11/24
REVISITED REVISITED RD-14mRD-14m APPLICATION ( APPLICATION (CANDUCANDU RELATED) RELATED)
Step 3: Calculation of NC scenario
Ch-to-Ch NC
“SG-NC”
Distinction between:SG NC SG NC (NCFM applicable)(NCFM applicable)Ch-to-Ch NC Ch-to-Ch NC (NCFM not applicable)(NCFM not applicable)
RM/V > ~ 500
![Page 51: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/51.jpg)
51/61
CONCLUSIONSCONCLUSIONS
A SYSTEM SCALING STUDY WAS THE PRECURSOR FOR THE DERIVATIONOF THE NCFM.
NCFM GATHERS ITF PWR SIMULATORS DATA.
NCFM CAN BE USED TO SUPPORT:• SCALING STUDIES,• DESIGN/OPTIMISATION OF NC SYSTEMS,• VALIDATION OF COMPUTATIONAL MODELS, • JUDGING THE NC PERFORMANCE.
NCFM APPLICATION SHOWS GOOD NC PERFORMANCE OF CONSIDEREDNPP (E.G. VVER-1000 AND ATUCHA PHWR). “LOWER” NC PERFORMANCEIS PREDICTED FOR B&W PWR AND CANDU (HOWEVER, THE EVALUATIONIS AFFECTED BY THE QUALITY OF THE AVAILABLE DB AND BY THE USED COMPUTATIONAL TOOLS).
BY-PRODUCTS OF THE ACTIVITY BRINGING TO THE NCFM, E.G MAX POWERREMOVABLE IN NC IN PWR SYSTEMS IN 1NC AND 2NC (SEE APP. 1)
![Page 52: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/52.jpg)
52/61
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
ADDITIONAL RESULT FROM THE NCFM DB
The objective is an estimation of the maximum thermal power removable by NC in PWR systems. This may be relevant in the unlikely event of ATWS-MCP trip and in the design of NC based new reactors. However, no care is given to the TH-NK feedback.
The analysis is carried out into two parts:a) related to ITFb) related to a PWR.
In all cases, the primary system pressure and the SG conditions (pressure, level and FW temperature) are kept constant at the nominal values if not differently specified. The MCP are at zero speed and the locked rotor hydraulic resistance of the impeller is taken into account. The core power and the FW flow are consistently varied.
![Page 53: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/53.jpg)
53/61
ADDITIONAL RESULT FROM THE NCFM DB
Removable power by Natural Circulation in ITF
ITF Core power when void
achieves 0.1 at the upper core level (°)
Core power when dryout
occurs (°)
Void at the upper core level
when dryout occurs
Primary system mass inventory
at dryout (°)
G/P at dryout
(Kg/MWs)
RM/V at dryout (Kg/m3)
Bethsy 15 70 0.8 69 1.12 475 Lobi 20 70 0.7 80 1.23 570 Lstf 10 30 0.9 62 1.87 480 Spes 15 50 0.6 75 1.29 528 (°) % of the nominal operational value
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
![Page 54: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/54.jpg)
11/61
ADDITIONAL RESULT FROM THE NCFM DB
Removable power by Natural Circulation in ITF: NC conditions relevant for calculating the maximum removable
thermal power in the NPP and in the ITF.
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
![Page 55: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/55.jpg)
11/61
ADDITIONAL RESULT FROM THE NCFM DB
Removable power by Natural Circulation in ITF: core flowrate versus core power at different pressure and temperature related boundary conditions
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
![Page 56: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/56.jpg)
56/61
ADDITIONAL RESULT FROM THE NCFM DB – PWR-1 calc. No. ID. P
MW/% G
(Kg/s)/% SG PRE
MPa RM
KgE5/% PS PRE
MPa UP T/Tsat
K UP Void
- G/P
Kg/sMW RM/V Kg/m3
1# KK01 1876/100 9037/100 6.1 1.08/100 15.6 598/618 0. 4.82 647 2^ KK01 56/3.0 520/5.8 8.1* 1.08/100 13.6 577/608 0. 9.28 647 3 KK01 376/20. 930/10.3 6.0* 1.08/100 15.4 615/617 0. 2.47 647 4 KN03 469/25. 1016/11.2 6.0* 1.07/99.1 16.2 620/620 0.10 2.17 641 5 KN04 563/30. 1140/12.6 6.0* 1.01/94.0 16.2 620/620 0.21 2.02 605 6 KN05 938/50. 1370/15.1 6.0* 0.92/85.0 16.2 620/620 0.47 1.46 550 7 KN07 1032/55. 1396/15.4 6.0* 0.90/83.3 16.2 620/620 0.48 1.35 539 8 KN08 1126/60. 1428/15.8 6.0* 0.89/82.9 16.2 620/620 0.49 1.27 536 9 KN09 1219/65. 1450/16.0 6.0* 0.88/82.0 16.2 620/620 0.51 1.19 529 10§ KN10 1313/70. 1490/16.4 6.0* 0.87/80.8 16.2 620/620 0.62 1.13 523 11 KL10 1032/55. 1396/15.4 3.5* 0.99/91.4 16.2 620/620 0.44 1.35 592 12 KL10 1313/70. 1650/18.3 3.5* 0.95/88.2 16.2 620/620 0.49 1.26 571 13§ KL12 1500/80 1492/16.5 3.5* 0.91/84.6 16.2 620/620 0.60 0.99 547 14§ KL11 1688/90. 1523/16.8 3.5* 0.87/80.4 16.2 620/620 0.77 0.90 520 15 LL11 1032/55. 1365/15.1 3.5** 1.01/93.9 16.2 620/620 0.31 1.32 608 16§ LL11 1688/90. 1525/16.9 3.5** 0.93/86.3 16.2 620/620 0.57 0.90 556 17 LL12 1500/80. 1380/15.3 3.5** 0.96/88.8 16.2 620/620 0.49 0.92 575 18 LL13 1032/55. 1300/14.4 2.5** 1.04/96.3 16.2 620/620 0.20 1.26 623 19 LL13 1500/80. 1750/19.4 2.5** 1.00/92.3 16.2 620/620 0.48 1.17 597 20 LL14 1688/90. 1460/16.2 2.5** 0.97/89.4 16.2 620/620 0.50 0.87 578 21§ LL15 1876/100. 1587/17.5 2.5** 0.94/86.6 16.2 620/620 0.63 0.85 560 22 HL15 1032/55. 1290/14.3 2.5** 1.09/101. 18.5 631/633 0.01 1.25 652 23§ HL15 1876/100. 1630/18.1 2.5** 0.97/89.3 18.5 633/633 0.58 0.87 578 24 HL16 1032/55. 1295/14.3 2.5+ 1.09/101. 18.5 594/633 0. 1.25 652 25§ HL16 1876/100. 1630/18.1 2.5+ 0.99/91.4 18.5 633/633 0.50 0.87 590
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
![Page 57: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/57.jpg)
57/61
ADDITIONAL RESULT FROM THE NCFM DB – PWR-1 calc.
NOMENCLATURE FOR THE TABLE IN THE PREVIOUS SLIDE
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
Nomenclature ID Calculation identification § Dryout occurrence G Core flowrate # Nominal working conditions for the system P Core Power ^ Reference NC result PRE Pressure * FW temperature same as in nominal condition PS Primary System ** FW temperature set at 363 K RM Mass Inventory in PS + FW temperature set at 333 K T Fluid Temperature + FW G set at 1.3 times the equilibrium value Tsat Saturation temperature UP Upper Plenum Void Void fraction
![Page 58: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/58.jpg)
11/61
ADDITIONAL RESULT FROM THE NCFM DB
Primary system mass inventory versus core power at different pressure and temperature boundary conditions (ITF and PWR-1)
P (%)
0 20 40 60 80 100 120
RM
(%
)
20
30
40
50
60
70
80
90
100
110
Nominal conditions NCNominal conditions NC (dryout occurrence)Low SG pressure NCLow SG pressure NC (dryout occurrence)NC at low SG pressure and low FW temp.NC at low SG pressure and low FW temp. (dryout occ.)NC at low SG pressure and high PS pressure (dryout occ.)ITF max NC with dryout ITF NC experimental data
PWR-1&
ITF
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
(not properly scaled)ITF data
![Page 59: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/59.jpg)
11/61
ADDITIONAL RESULT FROM THE NCFM DB
Removable core power at different values of steam generator pressures.
SG pressure (MPa)
2 3 4 5 6 7 8
Core
pow
er (%
)
0
20
40
60
80
100
120
no dryout occurrencedryout occurrence
PWR-1
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
![Page 60: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/60.jpg)
11/61
ADDITIONAL RESULT FROM THE NCFM DB
APPENDIX 1 – APPENDIX 1 – THE MAX POWER REMOVAL BY NCTHE MAX POWER REMOVAL BY NC
Power removal by NC largely depends upon PS and SS TH boundary conditions.
Two TH thresholds are considered and no evaluation is given of the TH-NK coupling:
a) the void formation in the core (PWR behaves like a BWR) b) overpassing the CHF.
When PS and SS BIC are kept close to their nominal values:NC is effective for removing up to around 20% of core power, 2NC is effective for removing up to 70% of core power avoiding the
occurrence of the CHF.
100% core power can be removed in 2 NC, provided the SG pressure and the FW temperature are lowered to values of the order of 3 MPa and 100 °C, respectively. An increase of primary pressure also brings to increase the power removal capability by natural circulation.
![Page 61: THE USE OF THE NATURAL CIRCULATION FLOW MAP](https://reader036.fdocuments.us/reader036/viewer/2022062309/5681372a550346895d9eb68b/html5/thumbnails/61.jpg)
61/61
APPENDIX 2 APPENDIX 2
REFERENCE PAPERS
D’Auria F., Galassi G.M., Vigni P., Calastri A. “Scaling of Natural Circulation in PWR Systems”, J. Nuclear Engineering and Design, col 132 1991, pp 187-205
D’Auria F., Frogheri M., Leonardi M. “Natural Circulation Performance in Western type and Eastern type PWR”, Simulator Multiconference, San Diego (CA), April 11-13, 1994
D’Auria F., Galassi G.M., Frogheri M “Natural Circulation Performance in Nuclear Power Plants, 2nd Conf. of the Croatian Nuclear Society, Dubrovnik (HR), June 17-19, 1998
D'Auria F., Frogheri M., Monasterolo U. "Removable power by natural circulation in PWR systems“ - ASME-JSME Int. Conf. on Nuclear Engineering (ICONE-5) - Nice (F) May 26-30 1997 (ICONE5-2431)
Ferreri J. C., Mazzantini O., Ventura M. A., Rosso R.D., D'Auria F. "Natural circulation in the CAN-I PHWR NPP characterization based on flow maps"10th Int. Top. Meet. on Nuclear Reactor Thermalhydraulics (NURETH-10), Seoul (South Korea), Oct. 5-9 2003 D'Auria F., Frogheri M. "Use of Natural Circulation Flow Map for assessing PWR performance” Eurotherm Sem. No. 63: Single and Two-Phase Natural Circulation, Genova (I), Sept. 6-8 1999