The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS...

20
The ANTARES detector: The ANTARES detector: background sources and background sources and effects on detector effects on detector performance performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf of the ANTARES Collaboration

Transcript of The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS...

Page 1: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

The ANTARES detector: The ANTARES detector: background sources and background sources and

effects on detector effects on detector performanceperformance

S. Escoffier

CNRSCentre de Physique des Particules de

Marseille

on behalf of the ANTARES

Collaboration

Page 2: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Detection PrincipleDetection Principle

č

43°Sea floor

Reconstruction of trajectory (~ ) from timing and position of PMT hits

interaction

Cherenkov light from

3D PMTarray

Page 3: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

Background Background sourcessources

Page 4: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Atmospheric muons and Atmospheric muons and neutrinosneutrinos

Muons induced by atm

Atmospheric 10TeV

1TeV

1TeV

10TeV

(c

m-2

s-1

sr-1

)

pp,

Page 5: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Rejection of the atmospheric Rejection of the atmospheric backgroundbackground

• Optical Modules oriented downward• Detector at great depth (~2475 m)

Atmospheric muons

Atmospheric neutrinos

Energy spectral index E:

Some atm can be reconstructed as upgoingProblem:Problem:

• atm can be used for flux measurement

Advantage:Advantage:

=-2.2 / -2.0 for from cosmic accelerators=-3.7 for atm

Diffuse flux:Diffuse flux:

(moon shadow)

Point-like sources:Point-like sources:

Reduced background (see J. Aguilar’s talk)

• atm can be used for pointing accuracy

Page 6: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Optical backgroundOptical background

baseline

bursts

Bioluminescence bursts:Animal species which emit light by flashes, spontaneous or

stimulated around the detector.

Baseline:40K decays

Bacteria luminescence

Page 7: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Absolute PMT efficiencies, stable in time

4040K decaysK decays

14.5 ± 0.4 Hz

40K

40Ca

e- ( decay)

Cherenkov

13 Hz ± 4 Hz (syst.)

40K coincidence rate

Conclusions:

from Gaussian fit on data:

from simulation:

Agreement within 5%4040K constant contribution at 40 kHzK constant contribution at 40 kHz

Page 8: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Baseline variationsBaseline variations

2005

2006

Connection Line 1Connection Line 1 Connection Line 2Connection Line 2

Sometimes high bioluminescence activity

50 m

14.5 m

100 m

Buoy

top storey:1 optical modulecurrent profiler

middle storey:3 optical modules

bottom storey:LED beacon

base:acoustic transducer

MILOMMILOM

40K

Page 9: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

Effects of the Effects of the backgroundbackground

Page 10: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

StatusStatus Such a study requires detailed simulations for Such a study requires detailed simulations for

various values of baseline/burst fraction for various values of baseline/burst fraction for each each physics channelphysics channel

Impact of bioluminescence will be very different for:

Diffuse sources:Diffuse sources: no pointing accuracy, high energy cut ~50 no pointing accuracy, high energy cut ~50 TeVTeV

Point sources:Point sources: high pointing accuracy, no or moderate high pointing accuracy, no or moderate energy cutenergy cut

Transient sources:Transient sources: reduced background due to time reduced background due to time constraintconstraint

Dark matter =Dark matter = low energy low energy

Page 11: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Neutrino effective areaNeutrino effective area

Page 12: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Impact on the data Impact on the data acquisitionacquisition

Bioluminescence burst > 500 kHz

High rate vetoHigh rate veto: OM data is not transmitted to shore during burst.: OM data is not transmitted to shore during burst.

Baseline > 300 kHz

SamplingSampling: N / M frames are transmitted to shore: N / M frames are transmitted to shore

Off-shore trigger L1: Off-shore trigger L1: only local coincidences transmitted to only local coincidences transmitted to shore shore

Baseline < 300 kHz

All data to shoreAll data to shore

Page 13: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

Some ideas are Some ideas are being studied…being studied…

Page 14: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Standard triggerStandard trigger

New trigger :N local coincidences with a 3D causality trigger

Old trigger :N local coincidences anywhere inside the detector

For N=5,

accidental trigger rate increases as f 10

Problem:Problem:

Online Data filterLevel 1 Trigger (L1):Level 1 Trigger (L1):

• Look for local coincidences (2/3 OMs in the same storey)

or • Charge > 3 p.e. on a single OM

Page 15: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Generated eventGenerated event

1 hit in storey

2 hits in storeyin 1 same OM

3 hits in storey

2 hits in storeyin 2 different OM

3 hits in storeyin 2 different OM

Trajectory of lightfrom track to OM

track

One event produce hits in cluster of storeys

ANTARES lines

Page 16: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Alternatives triggerAlternatives trigger

Causality algorithms :N x T2/T3 with a causality requirement

Cluster trigger :Cluster T2 =Cluster T2 = Two L1 in adjacent storeys

Cluster T3 =Cluster T3 = Two L1 in next to adjacent storeys

To remove noise hits…

Work in progress

Page 17: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

ConclusionConclusion

Page 18: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Review of the Review of the bioluminescence activitybioluminescence activity

2007

Connections LineConnections Line 3,3, 44 && 55

(6 months)

2006

Connection Line 1Connection Line 1 Connection Line 2Connection Line 2

Page 19: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

Latest bioluminescence Latest bioluminescence activityactivity

Proportion of time where mean counting rate higher than given value

SpringSpring 20062006

Spring Spring 20072007

SummerSummer 20062006

Autumn Autumn 20062006

Winter Winter 2006/72006/7

Bioluminescence activity is very low since one year

Page 20: The ANTARES detector: background sources and effects on detector performance S. Escoffier CNRS Centre de Physique des Particules de Marseille on behalf.

S. Escoffier, ANTARES background sources and effects ICRC ’07, Merida

ConclusionsConclusions

Background sources are being understood

• To optimize trigger and reconstruction efficiencytrigger and reconstruction efficiency at high bioluminescence levels

Bioluminescence activity is low since 1 year

Studies are still in progress:

Some seasonal effects can appear, due to biological activity

• To evaluate precise effects of high bioluminescence activities on the detector performances (effective area, pointing accuracy, dead time, …)

A lot of data to analyse