Models:
• Highly efficient heat recovery(� > 80%)
• Energy-efficient integrated direct-current fans
• 4-step Simple Control adjustment• Preheating with electricity (option)
SC
• 1.09.346F• 22.11.2012• Code A3521-1/2© VALLOX
Code A3521-1/2
Supply air
Extract air
92 dm3/s 50 Pa
75 dm3/s 50 Pa0,119 kW 0,9 A
0,119 kW 0,9 A
Heat recovery
Heat recovery bypass
Filters
– Simple Control controller, 0...10 VDC
– PTXPA Slim-Line SC cooker hood
– Simple Control controller, 0...10 VDC
– PTXPA Slim-Line SC cooker hood
– Insulated attic floor penetration plate
– Ceiling mounting plate Vallox 90
– Electric preheating unit max. 1000 W
– Supply air filter F7
Power adjustment of ventilation
Electrical connection 230 V, 50 Hz, ≈ 1.8 A(+ preheating unit 4.3 A)
Class of protection IP 34
Weight
Options
Fans
direct current (DC)
Extract air
Supply air
Cross-counter flow cell, >80 %
Seasonal damper
G4 and F7 (F7 option)
G4
52 kg
ValloxSC90
-
687.
7
597
82.6
83.2
160
360.
4
157.5 157.2 117.2
157.5 82.6
83.2
360.
4
157.2117.2
160
© VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.
VALLOX 90 SCDIMENSIONS AND MAIN PARTS
22
Main parts
Extract air fan
Supply air fan
Preheating radiator (option)
Measurement outlets
Heat recovery cell
Outdoor air filter F7 (option)
1
2
3
5
6
4
7
8
9
1010
11
12
Outdoor air filter G4
Extract air filter G4
Summer / winter damper
Summer / winter damper lock
Safety switch
Speed selector swich (option)
Dimensions and duct outlets
R MODEL
1
2
Supply air to dwelling
Extract air from dwelling
Outdoor air to unit
Exhaust air out
3
4
Duct outlets, inner diameterof collar ø 125 mm
L MODEL
Measurement outlets
Condensing water outlet
The condensing water outletis located up in the backof the unit.
Fastening brackets
The fastening brackets arelocated up at the bottomof the unit.
13 Connection box
1
2
3
4
1
2
3
4
12
Measurement outlets are located behind the machine plate. Detachthe machine plate by pushing it to the left and pull the outlets out.
13
Model R
7
11
6
2
4
5
1
10
3
9
8
-
dm3/s
© VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.
Air volumes
SUPPLY / EXTRACT AIR VOLUMES / VALLOX 90 SCMeasuring points after the connectionoutlet.Fan curves indicate the total pressureavailable for duct losses.
Extract airSupply air
S
E
Sound power level from the ventilation unitto supply air ducts by octave band Lw, dB
Medium
frequency
of the octave
band, Hz
ADJUSTING VOLTAGE/AIR FLOW
Sound power level from the ventilation unitto extract air ducts by octave band Lw, dB
ADJUSTING VOLTAGE/AIR FLOW
ADJUSTING VOLTAGE/AIR FLOWS (supply/extract)
A-weighted sound pressure level dB (A) comingfrom the unit through the envelope to the rooms wherethe unit has been installed (10 m2 sound absorption)
63
125
250
500
1000
2000
4000
8000
LW, dB
LWA, dB(A)
Hz
LpA, dB(A)
VALLOX 90 SCPERFORMANCE
3
SFP (Specific Fan Power)guideline value < 2.5 (kw/m3/s)
SFP=Input power (total) (W)Air flow (max) (dm3/s)
Sound values
Supply air, 2…10 VExtract air, 2…10 V Fan controlvoltage
(V)
Total inputpower
W
Pres
sure
loss
in du
cts. T
otal
pres
sure
Volume flow rate
Pa
0
50
100
150
200
250
300
0 10 20 30 40 50 60 70 80 90 100 110
VALLOX 90 SC
3
4
4,5
5,2
6
7
8
10
9
15
22
31
47
72
114
182
3,6 V17/24 l/s
5,4 V29/39 l/s
7,3 V44/56 l/s
10,0 V69/81 l/s
23,9 30,6 38,0 45,3
3,6 V16,5 l/s
5,4 V27,2 l/s
7,3 V40,9l/s
10,0 V65,6 l/s
61,7
46,9
39,6
35,1
31,1
13,0
61,8
38,5
67,2
56,2
47,0
41,6
38,7
25,7
15,6
67,6
46,1
73,1
64,3
54,4
48,6
45,7
34,4
27,5
20,0
73,7
53,3
82,1
73,4
63,5
57,3
52,4
43,5
35,9
22,6
82,7
61,9
56,9
46,4
39,5
32,7
27,9
17,6
57,4
36,4
63,9
53,9
44,6
38,8
35,5
24,5
13,3
64,3
43,5
69,6
60,8
52,2
45,6
43,2
33,6
23,2
70,2
50,5
75,6
69,1
61,0
53,3
48,9
42,9
33,8
76,7
58,2
3,6 V23,8 l/s
5,4 V35,8 l/s
7,3 V51,9 l/s
10,0 V76,7 l/s
S 3V
E 3VS 4V
E 4V
S 4,5V
E 4,5V
S 5,2V
E 5,2V
S 6V
E 6V
S 7V
E 7VS 8V
E 8V
S 10V E 10V
EK
SK
SFP 1,5 kW/m3/s
-
© VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.
Selection of fan speedFan speed is selected by using a separate speed selector.Speed selectorThe speed selector can be used to select speeds 1, 2, 3 and 4:1. Use during absence. When the dwelling is empty, ventilation can temporarily be
diminished.2-3. Normal use. In normal conditions air needs to be replaced once in two hours.4. Boosted operation. Cooking, bathing in the sauna or bathroom, drying clothes,
using the toilet, having guests, overheat or a similar situation may cause a need forhigher than normal ventilation.
If there is a cooker hood independent of the ventilation system in the dwelling, it is notnecessary to raise the speed of VALLOX 90 SC during cooking.
Heat recovery bypassIn winter use the heat recovery cell of VALLOX 90 SC recovers heat from the air leaving thedwelling and uses it to heat the air coming from the outside.In summer use when it is warm outside, it is unnecessary to heat outdoor air. The heat recoverycell is bypassed in VALLOX 90 SC with the standard damper (A). The position of the dampercan be changed by opening the damper release (B) and then moving the damper in anotherposition. In the summer position air flow through the cell is prevented, and heat recovery bypassis activated.
Air filteringVALLOX 90 SC features coarse filtering of both extract and supply air before the fans. Thesupply air side includes a G4 class coarse filter (C) and the extract air side a G4 class coarsefilter (D). The unit can also be equipped with a F7 fine filter (E), which captures fine dust andpollen as well dust not seen to the eye. The filters need to be in place in the unit wheneverventilation is in operation.
DefrostingWater condensing from extract air may freeze in the heat recovery cell. Freezing can beprevented by stopping the supply air fan, or the unit can be equipped with a preheating resistor,which is switched on as needed.
Stopping the supply air fanThe defrost thermostat T1 stops the supply air fan whenever the temperature of extract air isbelow +5 °C after the cell. The fan restarts when temperature has risen by circa three degrees,i.e. to 8 °C. The limit of the thermostat (F) can be adjusted at the back of the heat recovery cell.If the unit includes a preheating radiator (G), the supply air fan cannot be stopped.
Outdoor preheatingThe unit can have been equipped with a preheating radiator at the factory. If that is the case,the defrost thermostat T1 switches the preheating radiator on whenever the temperature ofextract air goes below +5°C after the cell. The preheating radiator is switched off whentemperature has risen by circa three degrees to +8°C. The preheating radiator heats outdoorair before the heat recovery cell and prevents it from freezing. In very cold temperatures thepreheating radiator is not enough to heat maximum air flow to a sufficient degree (in atemperature of minus 30 degrees, maximum air flow is 30 dm3/s, which corresponds to speed2). The limit of the thermostat can be adjusted at the back of the heat recovery cell.
F
Preheatingradiator (G)(option)
Note! The heatingradiator is tubularand can bescalding hot.
Damper in summer position
Damper in winter position.You can return the replacement damper tosummer position by pulling the releasedamper towards yourself.
Speed selector
G
AB
CD
E
G
VALLOX 90 SCOPERATION
24
Defrost thermostat (F)First remove the heat recoverycell, then the cap protecting theadjusting screw of the thermostat.
F
-
VALLOX 90 SC
LED
LED
1000W
1 210VDC- +
950511
1 2 3 4 5 6
950511
T1
14
BK
YE RD BU
E
BL
GY
BK
YE/G
N
BK BK
YE/G
NBU
BN
YE
BU
N
11
NL1 L
1 N
RDBU
BN
LS10 VDC N
BK
L27
BL
3x0,5
NL (230 V)
10A
3 X 1.5 S
KK
S
R1
BN
1 N 1 N
BU
YE/G
N BU
YE/G
N
BN
9510
49
BN
9510
50
NL
K
Vallox 90SC
BN
8 9
3 X 1.5 S
NL (230 V)
10A
KK
Vallox 90 SC+
Vallox 90 SC
S
S-
PL 11
12S 3 4
10VDC+
1 N
GYBK BK
BK
9510
2295
1049
9510
50
BN GY
BK
951016951016
9510
21
-
10VDC
S10VDC
-
S-
12 3 4
-+
S
-+S
LN
OK
S
10VDC+
OK
-
BU
9509
57
951016951016
- +
- +
950115
WT BN
GN
9505
2095
0582
BK
9505
17 B
U950516 BU 950581 BU
10 11 12
L
BUYE/G
N
T3 11
12
© VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.
ELECTRICAL DIAGRAMS
5
CONNECTION BOX(on top of the unit)
SC cooker hood, e.g.PTXPA SC 600 Slim-Line
4-speed SC cam switch
4-speed SC cam switch or SC cooker hood
S Supply air fanE Extract air fanK Safety switchKK Operating switchT1 Antifreeze thermostat
Supply air fan stops at +4 °C(alternative connection)
T3 Antifreeze thermostatPreheating radiator on at +5 °C
R1 Preheating radiator (option), with 90 °Cand 130 °C overheat protection
OK Voltage switch (in cooker hood)
Wire coloursBU = blueBK = blackBN = brownWT = whiteGN = greenRD = redGY = greyYE/GN = yellow/green
-
VALLOX 90 SC
© VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.
6
CONTROL DIAGRAMDI
STRI
BUTIO
NPA
NEL
10A
230
V 50
Hz
VALL
OX 9
0 SC
INTE
RNAL
ELEC
TRICA
L AND
CONT
ROL C
ONNE
CTIO
NS
G4G4
F7LP1
HR
H
TS1
EFM
SILEN
CER
SILEN
CERRE
MOTE
MON
ITORI
NG CO
NTRO
L CEN
TRE
OF TH
E PRO
PERT
YCO
NTRO
L
FAN
SPEE
D CO
NTRO
L SWI
TCH
S
VENT
ILATIO
N ZO
NE
MSF
6
10A
TS1
M
TS1
-
VALLOX 90 SC
© VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.
Parts list VALLOX 90 SCCode Name Technical data Standard
/ Option
G4 F7 Filter Supply air G4 + F7 (option) StandardExtract air G4
H HR bypass damper Manual StandardHR Heat recovery cell Cross-counter flow cell, efficiency 80% StandardEF Extract air fan (DC – direct current) qv = 92 dm3/s (50Pa) StandardTS1 HR defrost thermostat Factory setting +5°C StandardSF Supply air fan (DC – direct current) qv =75 dm3/s (50 Pa) StandardS 4-step adjustment switch 1, 2, 3, 4 switch OptionLPl Preheating radiator PTC resistor max. 1.0 kW Option
7
DESCRIPTION OF OPERATION
Control of operationPower supply to the unit can be controlled with the 0/1 switchin the distribution panel if needed. After starting, the unit operatesat the power selected on the fan speed control switch. There isalso a safety switch SS inside the unit. It stops power supply whenthe maintenance door of the unit is opened.
Fan speed adjustmentCam switchThe SF and EF fans of the unit are controlled, depending onoperating conditions, with a separate 4-step SC cam switchlocated in the ventilation zone.
Voltage signal controlThe fan power of the unit can be controlled steplessly with voltagesignal 0...10 VDC. With a voltage signal lower than 1.5 VDCthe fans stop.
Heat recovery bypassSummer-time bypass (H) of the heat recovery cell HR is donemanually by turning the HR damper in the bypass position for thesummer.
Heat recovery defrostingThe defrost thermostat TS1 of the HR cell stops the supply air fanSF, preventing the HR cell from freezing. The fan starts automaticallyas soon as the risk of freezing has passed. The operating point ofthe defrost thermostat cannot be changed, the factory setting is+5°C.The unit can alternatively be equipped with preheating radiatorLP1, controlled by antifreeze thermostat TS1. When there is a riskof frosting, preheating radiator LP1 starts to heat air coming fromoutside to the unit, thereby preventing the HR cell from freezing.The tubular preheating resistor is connected to 90°C (resetting)overheat protection and 130°C (not automatically resetting) overheatprotection.Note! The preheating radiator can be scalding hot, especially in winter.
-
VALLOX 90 SC
© VALLOX • We reserve the right to make changes without prior notification.What the units include can vary depending on the sales area.
Vallox Oy • Myllykyläntie 9-11 • FI-32200 Loimaa • Tel. +358 10 7732 200 • www.vallox.com
LOCATION AND MOUNTING OF VALLOX 90 SC
LOWER EDGEOF BRACKET
1.09
.346
E/22
.11.
2012
/PD
F
InstallationVALLOX 90 SC has to be mounted in a place wheretemperature does not fall below +10 ˚C. Without protectivecasing, the unit must be located in a place with no acousticdisturbance: storerooms, technical rooms etc.
Wall mountingVALLOX 90 SC is mounted on the wall with a fixing plateas shown in the adjacent figure.Wall constructionWhen fixing the unit, take the wall structure into account.Because of sound conduction, avoid mounting the unit ona hollow, echoing dividing wall and on a bedroom wall; or,if you do, prevent sound conduction.
Wall mounting plate
Condensing waterThe delivery includes a water seal. With a pipe connected to the water seal,water condensing from extract air can be led to a floor drain (not straightto the drain).The pipe must not rise after the water seal. The unit has to be mounted levelwith the horizontal in order to ensure that condensing water can get out ofthe unit.
Ceiling mounting/ceiling mounting plateFastening of ceiling mounting plate to ceilingThe ceiling mounting plate is mounted straight, and it has to befastened so that there is a space of circa 6 mm between the backedge of the ceiling mounting plate and the wall (Figure 1).Theventilation unit then becomes attached to the back wall.Minimum distance between the lower edge of the ceiling mountingplate and the ceiling of the room is 14 mm. With this distance,there will be a vent of circa 2 mm between the upper edge of themounted unit and the ceiling.The ceiling mounting plate is fixed to the ceiling with M8 threadbars. After the thread bars have been fastened to the ceiling, firstturn the nuts into the thread bars and lift the ceiling mounting platein place. Then push a rubber damper and washer to each threadbar, all the way into the cup of the plate, and turn the nut.Shorten the lower ends of the thread bars so that they will be atno more than 25 mm from the lower surface of the ceiling mountingplate. NOTE! Shortening the thread bars can only be done beforemounting the ceiling mounting plate. The maximum length of athread bar from the lower surface of the ceiling is the spacebetween the lower surface of the ceiling and the lower surface ofthe ceiling mounting plate + 25 mm.
Figure 1
Figure 2
14 pcs
NutsDamper rubber
Lower surface of ceiling
Washer
ceiling
wall
LOCKING WINGS
Mounting of ventilation unit to ceiling mounting plateBefore lifting the unit to the ceiling mounting plate, detach the following items from the unit(Figure 2):1. Thermostat knob (SC unit)2. Front panel (leave it hanging from the measurement hoses)Put the cables of the connection box into the slot in the upper part of the side plate and pullthe connection box next to the unit so that the cables remain in the slot. Make sure that theduct outlets for the unit’s extract air duct and for the duct coming from the outside to the unitare equipped with condensing water insulation. Lift the unit in place to the ceiling mountingplate till both locking wings lock to the outer edge of the side plate of the unit. Do a visualcheck of the tightness of the duct outlets and of the correct moving of the measurement hosesand electric cables. Fasten the front panel and the knob of the thermostat (SC unit) back inplace.
at le
ast 1
4
LOWER EDGEOF BRACKET
THE LEAD-IN OF ELECTRICWIRES CAN BE DONE FROMBOTH SIDES OF THE UNIT.
DURING MOUNTING THEUNIT RISES 10 MM HIGHERTHAN THE FINAL HEIGHT.
Condensing water outletand water seal Silent Klick