Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for...
Transcript of Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for...
BlueSkyBlueBlueVallox
AIR DISTRIBUTION SYSTEMTechnical instructions Planning and installationinstructionsPlanning and installationinstructions
Vallox BlueSky is a fl exible, sound attenuating and installation-friendly piping system for ventilation.
Speedy installation and the almost non-existent need for duct components make the Vallox BlueSky duct an affordable solution for both new building and renovation.
- outer diameter 75 mm- can be fully installed in warm rooms without large enclosures
- M1 classifi cation
- smooth inner surface – small fl ow resistance
when installed in blown wool insulation
- fl exible duct
already at the stage when the building frame is being made, in the same way as electricity and sewage installations.
2
BlueSkyBlueBlueVallox
- air distribution system
which is easy to clean.
unit and the air distribution box.
TECHNICAL DATA
2
sound-insulated air distribution box. Because the air fl ow
natural basic adjustment. It is extremely easy to measure
Flexible and installation-friendly piping system for ventilation
3
BlueSkyBlueBlueVallox
- air distribution system
Recommendation:
recommended.
Pressure loss is then 45 Pa.
Flow speed Air volume Flow resistance
m/s m3/h l/s Pa/m
pPa/m
2 4 5 8 10 20 30 40
1,8
1,6
1,6
1,21,11,00,90,80,70,60,50,40,30,20,1
2,8 5,6
m3/h
l/s8,3
pPa/m
10987654321
2 4 5 8 10 20 30 40
2,8 5,6 8,3
m3/h
l/s
Pressure loss in Vallox BlueSky duct
3
3
Dimensioning of extract and supply air ducts Pressure loss
in Vallox BlueSky 90° bend
VALVE OUTLETS Depending on air fl ow, the use of one or two ducts leads to a natural basic adjustment and facilitates the fi nal measurement of air fl ows.
Pipe diameter: Outer ø 75 mm, inner ø 63 mm, A = 0.0031 m2
Example of pressure loss in supply air ductwork to the farthest bedroom 8 l/s
Example of pressure loss in extract air ductwork from washroom 10 l/s
Total 44 Pa
4
3
3
3
LIVING ROOM
WALK-IN CLOSET
DV
DV
DV
DV
DV
DV
DV
DV
BEDROOM
BEDROOM
HALL
COLD-STORAGE ROOM WC
KITCHEN
ENTRANCE TAMBOUR
WOOD STORAGE ROOM
CHANGING ROOM
WASHING ROOM
SAUNA
Cooker hood 0 (-20)
KTS 125 +6 above sauna stove
Extraction to the roofLPV Ø 160 Vilpe
Vallox 110 MV
KSO 125- 6
KSO 125-10
TINO-D+8
TINO-D+8
TINO-D+9
TINO-D+12
TINOi-D-10
TINOi-D-3
TINOi-D-8
ø 160
ø 160
KSO 125-10
Ducts from distribution boxes onward ø 75/63
SUSPENDED ENCLOSURE 200 mmSUSPENDED ENCLOSURE 100 mmCARBON DIOXIDE SENSOR HUMIDITY SENSORSILENCER
BEDROOM
PLANNING OF BlueSky VENTILATION SYSTEM
BlueSkyBlueBlueVallox
- air distribution system
Renovation house
Pressure loss
Duct volume
Calculation for valve coupling units
Other ducts
BlueSky supplies
5
3
3
3
LIVING ROOM
WALK-IN CLOSET
DV
DV
DV
DV
DV
DV
DV
DV
BEDROOM
BEDROOM
HALL
COLD-STORAGE ROOM WC
KITCHEN
ENTRANCE TAMBOUR
WOOD STORAGE ROOM
CHANGING ROOM
WASHING ROOM
SAUNA
Cooker hood 0 (-20)
KTS 125 +6 above sauna stove
Extraction to the roofLPV Ø 160 Vilpe
Vallox 110 MV
KSO 125- 6
KSO 125-10
TINO-D+8
TINO-D+8
TINO-D+9
TINO-D+12
TINOi-D-10
TINOi-D-3
TINOi-D-8
ø 160
ø 160
KSO 125-10
Ducts from distribution boxes onward ø 75/63
SUSPENDED ENCLOSURE 200 mmSUSPENDED ENCLOSURE 100 mmCARBON DIOXIDE SENSOR HUMIDITY SENSORSILENCER
BEDROOM
DIMENSIONINGVallox 110 MV R
SUPPLIES
1
roll44
4
41
11
m5
List of suppliesVallox 110 MV R
InsulationSupply and extract air ducts do not need insulation below the vapour barrier. Outdoor and exhaust air ducts are insulated below the vapour barrier with 19-mm cellular plastic and above the vapour barrier with 50-mm wool (no vapour-proof surface).
Indicative calculation of supplies for BlueSky air distribution system
BlueSkyBlueBlueVallox
- air distribution system
DV = Door vent:Rooms to which 15...20 mm of air is broughtRooms from which circa 10 mm of air is extracted20 mm in the door between the door of the bathroom next to the sauna and the dwelling
6
Ducts and parts
Outer connector for BlueSky duct.
10 pcs/bag.
Flexible ventilation duct.- roll 50 running metres- outer ø 75 mm- inner ø 63 mm
BlueSkyBlueBlueVallox
- air distribution system
150
- duct outer ø 75 mm
Duct size, ø125 mm.Air volume 17 l/s 8 Pa.Pipe outlets 2 x 75 mm. Stop plug.
Duct size, ø125 mm. Air volume 17 l/s 4/6 Pa.Pipe outlets 2 x 75 mm. Stop plug.
78
78
100 180
1005080
DN 125
L280
Vallox BlueSky 75/63 PIPE
WASHER RING FOR PIPE 75 mm Dimensions
BEND 90° 75 mm Dimensions
CONNECTION PART FOR VALVE / BACK CONNECTION Dimensions
OUTER CONNECTOR 75 mm Dimensions
CONNECTION PART FOR VALVE/SIDE CONNECTION Dimensions
ø 75
Galvanised steel sheet.For narrow places where the bending radius of BlueSky pipe is not enough.
200 100 50
12578 15
060
d d
200 mm
50 50100
150 mm60
7
Supply and extract air valves
needed.
59
90
ø80
50
nim
.
42
ø12mm
255
150
90
59
ø3,3 mm
150
255 50 42
nim
.ø80
BlueSkyBlueBlueVallox
- air distribution system
SUPPLY AIR VALVE TINO-D
EXTRACT AIR VALVE TINOi-D
ADJUSTMENT OF Tino VALVES
Dimensions
Dimensions
Adjustment values
Adjustment values
- Supply air valve with two BlueSky duct joints- Valve meets the choke requirement for fi re valves (42 l/s/100 Pa)
- Extract air valve with two BlueSky duct joints- Valve meets the choke requirement for fi re valves (42 l/s/100 Pa)
Tino-D supply air valve
Tinoi-D extract air valve
TINO-D k
A 4.5
closed rows
4
8
TINOi-D k
A
closed rows
4
8
8
Air distribution boxes
Silencing, BlueSky air distribution box
BlueSky AIR DISTRIBUTION BOX 15, H = 300 Dimensions Air volumes
002
400 300
78
125
BlueSkyBlueBlueVallox
- air distribution system
Connection 160 mm
Connection 125 mm
H = 160
H = 200
Connection 200 mm
17 1715
15 outlets, dB 17 17
BlueSky AIR DISTRIBUTION BOX 6, H = 160/ H = 200 Dimensions Air volumes
BlueSky AIR DISTRIBUTION BOX 10, H = 200 Dimensions Air volumes
500 530
160
78
125
500 500
200
160 78
600
300
500
78
200
9
BlueSkyBlueBlueVallox
- air distribution system
10 pcs/bag
OUTLET COLLAR 75 mm + 2 locking devices
PLUG AND SEAL FOR 75 mm OUTLET COLLAR
LOCKING DEVICE
COVER FOR DISTRIBUTION BOX 75 mm
Dimensions
Dimensions
Dimensions
Dimensions
78
96
65
Accessories for air distribution boxes
96
78
38 mm
10
the ceiling.
installation!
INSTALLATION OF BlueSky AIR DISTRIBUTION SYSTEM
Installation in suspended enclosures or casings
no heat insulation is needed. If
insulation against condensation in the duct is necessary.
Attic fl oor installation
insulation, it is recommended to do
insulation for the attic fl oor insulation is enough for insulating the duct as well.
are insulated.
to be met.
VTT.
Fire protection and enclosure
ducts are enclosed with material of at least class
Supporting
all joints and on both sides of the connector outlet. There
Installation tips Installation regulations
BlueSkyBlueBlueVallox
- air distribution system
6
5
4
3
2
1
11
Intermediate fl oor installation 1. Floor coating2. Timber panel or plasterboard3. Vallox BlueSky pipe in insulation4. Ceiling below
Installation in concrete pouring
reinforcement or thin-shell slab and fi xed to the concrete reinforcement with cable ties. After the duct and other
the sound of the fan.
installation corners and their screws.
there is an outlet collar with a rubber ring.
after which one or more ducts can be connected to it.
tongues.
duct outlet.
duct outlet.
Installation of air distribution boxes and valve connection parts
1. Floor coating2. Cement mortar3. Building foil4. Soundproofi ng as required5. Concrete slab according to strength calculations, inside which the Vallox BlueSky pipes have been cast.6. Vallox BlueSky ventilation ductwork
BlueSkyBlueBlueVallox
- air distribution system
1
2
3
4
hot attic in summer.
Insulation of BlueSky ducts on fl oors and in cold rooms
other insulation than blown wool when the duct is installed
12
Vallox oy
BlueSkyBlueBlueVallox
- air distribution system
unit
Ducts in cold and warm roomsNote!The outdoor and exhaust air duct must not be installed inside attic insulation
Ducts in warm rooms – interior
Ducts in cold rooms– in the attic, attic insulation and above
Attic insulation
Attic insulation
Vapour barrier
Vapour barrier
DUCTS IN BLOWN WOOL
Vapour barrier
Vapour barrier
ROOF TRUSS
No insulation
Closed cell insulation 2 cm
Closed cell insulation 2 cm