Page 1: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

technical data

SplitSky Air

EEDE05-1/1

air cond

itioning

systems

Page 2: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

Zandvoordestraat 300

B - 8400 Ostend Belgium

www.daikineurope.com

Specifications are subject to change without prior notice

Het ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.

Daikin units comply with the European regulations that guarantee the safety of the product.

Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.

Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory.

Split - Sky Air

EED

E05-

1/1

- 03/

2005

Prin

ted

in B

elgi

um b

y G

oeki

nt G

raph

ics

Page 3: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

technical data

SplitSky Air

EEDE05-1/1

air conditioning systems

Page 4: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Split Sky Air • Outdoor Units 4

• Outdoor Units • R-22 • R-C

TABLE OF CONTENTSR-C

1 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

4 Capacity tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

5 Dimensional drawing & centre of gravity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

6 Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

7 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

8 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

9 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Page 5: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

5

11

tdoo lit C22

Ou Sp R- R- 1 Features

• Outdoor units for pair application

• Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall.

• Outdoor units are fitted with a rotary compressor, renowned for low noise and high energy efficiency

• Split Sky Air • Outdoor Units

Page 6: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

12

• Outdoor Units • R-22 • R-C

2 Specifications

2-1 TECHNICAL SPECIFICATIONS R25CV1A9 R35CV1A9 R50CV1A9 R60CV1A9

Casing Colour Ivory White

Dimensions Packing Height mm 599 599 732 732

Width mm 797 797 955 955

Depth mm 310 310 390 390

Unit Height mm 560 560 685 685

Width mm 695 695 800 800

Depth mm 265 265 300 300

Weight Machine Weight kg 27 33 49 61

Gross Weight kg 30 35 54 66

Heat Exchanger Dimensions Length mm 630 608 758 758

Nr of Rows 1 2 2 2

Fin Pitch mm 1.50 1.80 1.60 2.00

Nr of Passes 2 1.5 2 2

Nr of Stages 24 24 28 28

Tube type Hi-Xa(8)

Fin Type HL fin HL fin FL fin FL fin

Fan Type Propeller

Quantity 1 1 1 1

Air Flow Rate (nominal)

Cooling m3/min 29.0 27.0 40.5 40.5

Motor Quantity 1 1 1 1

Model KF-220-25L-1 KF-220-25L-1 53A-22 53A-22

Motor Speed (nominal at 230V)

Cooling rpm 720 710 855 855

Fan Motor Output W 25 25 53 53

Compressor Quantity 1 1 1 1

Motor Model RC30BV1R2T RC46AV1TRT RC60V1TNRT NH41VMDT

Type Hermetically sealed rotary compressor

Motor Output

W 700 1100 1500 2200

Operation Range Cooling Min °CDB 19.4 19.4 19.4 19.4

Max °CDB 46.0 46.0 46.0 46.0

Sound Level (nominal)

Cooling Sound Pressure

dBA 47.0 48.0 54.0 54.0

Refrigerant Type R22

Charge kg 0.76 0.95 1.35 1.70

Refrigerant Oil Type Suniso 4GSID Suniso 4GSID Suniso 4GSID MS-32

Charged Volume l 0.4 0.5 0.9 1.2

Piping connections

Liquid (OD) Diameter (OD)

mm 6.35 6.35 6.35 6.35

Gas Diameter (OD)

mm 9.5 12.7 15.9 15.9

Drain Diameter (OD)

mm 18 18 18 18

Piping Length Maximum m 25 25 30 30

Additional Refrigerant Charge kg/m 0.02/>10

Max. internunit level difference m 15.0 15.0 15.0 15.0

Heat Insulation Both liquid and gas pipes

• Split Sky Air • Outdoor Units 6

Page 7: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

7

12

2-2 ELECTRICAL SPECIFICATIONS R25CV1A9 R35CV1A9 R50CV1A9 R60CV1A9

Power Supply Name V1 V1 V1 V1

Phase 1 1 1 1

Frequency Hz 50 50 50 50

Voltage V 220-240

Current Nominal running current (RLA)

Cooling (A) A 3.78 5.38 7.12 10.70

Starting current (cooling/heating)

A 20.0 27.0 33.5 58.0

Voltage range Minimum V 207 207 207 207

Maximum V 253 253 253 253

Wiring connections

For Power Supply Quantity 3 3 3 3

For connection with indoor

Quantity 4 4 4 4

Remark included earth wiring

Power Supply Intake Outdoor unit only

NOTES

1 Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB, equivalent refrigerant piping : 7.5m, level difference : 0m.

2 Sound levels are measured in an anechoic room

3 Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter.

4 The sound power level is an absolute value indicating the power which a sound source generates

• Split Sky Air • Outdoor Units

Page 8: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

13

• Outdoor Units • R-22 • R-C

3 Electrical data

3D045936A

SYMBOLS

MCA: Min. Circuit Amps

TOCA: Total Over-current Amps

MFA: Max. Fuse Amps (see note 7)

LRA: Locked rotor Amps

RLA: Rated Load Amps

OFM: Outdoor Fan Motor

IFM: Indoor Fan Motor

FLA: Full Load Amps

kW: Fan Motor Rated Output

NOTES

1 RLA based on the following conditions:Indoor temp. 27°CDB/19°CWBOutdoor temp. 35°CDB

2 TOCA means the total value of each OC set.

3 Voltage range: units are suitable for use on electrical systems where the voltage supplied to the unit terminals is not below or above the listed range limits.

4 Maximum allowable voltage unbalance between phases is 2%.

5 Select wire size based on the larger value of MCA or TOCA.

6 Instead of fuse, use circuit breaker.

7 MCA/MFAMCA = 1.25 x RLA + all FLAMFA 2.25 x RLA + all FLA(next lower standard fuse rating Min. 15A)

8 Overcurrent relay trips when TOCA exceeds indicated value for more than 5 seconds within 16 seconds at 25 °C.

9 If TOCA exceeds indicated value, overcurrent relay trips when compressor head temperature greater than 1,00 °C.

10 For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select “Daikin Documentation” and select “conditional connection”, “the requested product type” and “English” from the drop down lists, click the search button. Finally, click on the document title of your choice.

Unit combination Power supply Compressor OFM IFM

Indoor unit Outdoor unit Hz-Volts Voltage range MCA TOCA MFA LRA RLA kW FLA kW FLA

FT25CV1A9 R25CV1A9

50-220Max. 50Hz - 264VMin. 50Hz - 198V 8.71 17.5 (note 8)

6.7 (note 9) 15

26.0 3.47

0.025 0.33 0.018 0.2850-230 27.0 3.51

50-240 28.0 3.60

FT35CV1A9 R35CV1A9

50-220Max. 50Hz - 264VMin. 50Hz - 198V 12.1 / 15

26.0 5.09

0.025 0.33 0.018 0.2850-230 27.0 5.11

50-240 28.0 5.12

• Split Sky Air • Outdoor Units 8

Page 9: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

9

13

3 Electrical data

3D040942B

SYMBOLS

MCA: Min. Circuit Amps

MFA: Max. Fuse Amps (see note 7)

LRA: Locked rotor Amps

RLA: Rated Load Amps

OFM: Outdoor Fan Motor

IFM: Indoor Fan Motor

FLA: Full Load Amps

kW: Fan Motor Rated Output

NOTES

1 RLA based on the following conditions:Indoor temp. 27°CDB/19°CWBOutdoor temp. 35°CDB

2 Maximum allowable voltage unbalance between phases is 2%.

3 Select wire size based on the larger value of MCA or TOCA.

4 Instead of fuse, use circuit breaker.

5 MCA/MFAMCA = 1.25 x RLA + all FLAMFA 2.25 x RLA + all FLA(next lower standard fuse rating Min. 15A)

6 For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select “Daikin Documentation” and select “conditional connection”, “the requested product type” and “English” from the drop down lists, click the search button. Finally, click on the document title of your choice.

Unit combination Power supply Compressor OFM IFM

Indoor unit Outdoor unit Hz-Volts Voltage range MCA MFA LRA RLA kW FLA kW FLA

FT50CV1A9 R50CV1A9

50-220Max. 50Hz - 264VMin. 50Hz - 198V 9.7 15

32.0 7.17

0.053 0.53 0.043

0.20

50-230 33.5 6.88 0.19

50-240 35.0 6.49 0.18

FT60CV1A9 R60CV1A9

50-220Max. 50Hz - 264VMin. 50Hz - 198V 14.3 25

55.0 10.87

0.053 0.53 0.043

0.20

50-230 57.5 10.38 0.19

50-240 60.0 9.89 0.18

• Split Sky Air • Outdoor Units

Page 10: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

14

• Outdoor Units • R-22 • R-C

4 Capacity tables

4 - 1 Capacity tables

FT25CV1A9 + R25CV1A9

3D045935

Cooling capacity (50 Hz, 220-240 V)

SYMBOLS

AFR: Air flow rate [m3/min.]BF: Bypass factorEWB: Entering wet bulb temp. [°CWB]EDB: Entering dry bulb temp. [°CDB]TC: Total capacity cooling [kW]SHC: Sensible heat capacity [kW]PI: Power input [kW]

NOTES

1 Ratings shown are net capacities which include a deduction for indoor fan motor heat.

2 shows nominal (rated) capacities and power input.

3 TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation).

4 SHC is based on each EWB and EDB.SHC* = SHC correction for other dry bulb.

= 0.02 x AFR [m3/min.] x (1-BF) x (DB*-EDB)Add SHC* to SHC.

5 Capacities are based on the folowing conditions.Corresponding refrigerant piping length: 5m(7.5m at [AS/NZS3823.1])Level difference: 0m

6 Air flow rate (AFR) and Bypass factor (BF) are tabulated below.

7 Add the following corrections to power input at [230V, 240V] as shown below.

Indoor Outdoor temperature (°CDB)EWB(°C)

EDB(°C)

20 25 30 32 35 40 46TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI

14.0 20.0 2.70 1.81 0.47 2.55 1.74 0.56 2.40 1.67 0.66 2.34 1.65 0.70 2.25 1.60 0.75 2.10 1.53 0.85 1.92 1.45 0.9616.0 22.0 2.81 1.85 0.49 2.71 1.78 0.59 2.56 1.71 0.68 2.50 1.68 0.72 2.41 1.64 0.78 2.26 1.57 0.87 2.08 1.48 0.9918.0 25.0 3.01 1.88 0.52 2.86 1.81 0.61 2.71 1.74 0.71 2.65 1.71 0.75 2.56 1.67 0.80 2.41 1.60 0.90 2.23 1.52 1.0119.0 27.0 3.09 1.90 0.53 2.94 1.83 0.63 2.79 1.76 0.72 2.73 1.73 0.76 2.64 1.69 0.817 2.49 1.62 0.91 2.31 1.54 1.0322.0 30.0 3.32 1.95 0.57 3.17 1.88 0.67 3.02 1.81 0.76 2.96 1.78 0.80 2.87 1.74 0.86 2.72 1.67 0.95 2.54 1.59 1.0724.0 32.0 3.48 1.98 0.60 3.33 1.91 0.69 3.18 1.84 0.79 3.12 1.82 0.83 3.03 1.77 0.88 2.88 1.70 0.98 2.70 1.62 1.09

FTAFR 8.3BF 0.33

Voltage PI [kW]230 V +0.026240 V +0.051

• Split Sky Air • Outdoor Units 10

Page 11: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

11

14

4 Capacity tables

4 - 1 Capacity tables

FT35CV1A9 + R35CV1A9

3D045937

Cooling capacity (50 Hz, 220-240 V)

SYMBOLS

AFR: Air flow rate [m3/min.]

BF: Bypass factor

EWB: Entering wet bulb temp. [°CWB]

EDB: Entering dry bulb temp. [°CDB]

TC: Total capacity cooling [kW]

SHC: Sensible heat capacity [kW]

PI: Power input [kW]

NOTES

1 Ratings shown are net capacities which include a deduction for indoor fan motor heat.

2 shows nominal (rated) capacities and power input.

3 TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation).

4 SHC is based on each EWB and EDB.SHC* = SHC correction for other dry bulb.

= 0.02 x AFR [m3/min.] x (1-BF) x (DB*-EDB)Add SHC* to SHC.

5 Capacities are based on the folowing conditions.Corresponding refrigerant piping length: 5m(7.5m at [AS/NZS3823.1])Level difference: 0m

6 Air flow rate (AFR) and Bypass factor (BF) are tabulated below.

7 Add the following corrections to power input at [230V, 240V] as shown below.

Indoor Outdoor temperature (°CDB)

EWB(°C)

EDB(°C)

20 25 30 32 35 40 46TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI

14.0 20.0 3.58 2.34 0.79 3.43 2.27 0.88 3.28 2.20 0.98 3.22 2.17 1.01 3.13 2.13 1.07 2.98 2.06 1.17 2.80 1.98 1.2816.0 22.0 3.74 2.38 0.81 3.59 2.31 0.91 3.44 2.24 1.00 3.38 2.21 1.04 3.29 2.17 1.10 3.14 2.10 1.19 2.96 2.01 1.3118.0 25.0 3.89 2.41 0.84 3.74 2.34 0.93 3.59 2.27 1.03 3.53 2.24 1.07 3.44 2.20 1.12 3.29 2.13 1.22 3.11 2.05 1.3319.0 27.0 3.97 2.43 0.85 3.82 2.36 0.95 3.67 2.29 1.04 3.61 2.26 1.08 3.52 2.22 1.135 3.37 2.15 1.23 3.19 2.06 1.3422.0 30.0 4.20 2.48 0.89 4.05 2.41 0.98 3.90 2.34 1.08 3.84 2.31 1.12 3.75 2.27 1.17 3.60 2.20 1.27 3.42 2.11 1.3824.0 32.0 4.36 2.51 0.92 4.21 2.44 1.01 4.06 2.37 1.11 4.00 2.34 1.14 3.91 2.30 1.20 3.76 2.23 1.30 3.58 2.15 1.41

FTAFR 8.4BF 0.24

Voltage PI [kW]230 V +0.035240 V +0.065

• Split Sky Air • Outdoor Units

Page 12: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

14

• Outdoor Units • R-22 • R-C

4 Capacity tables

4 - 1 Capacity tables

FT50CV1A9 + R50CV1A9

3D045959

Cooling capacity (50 Hz, 220-240 V)

SYMBOLS

AFR: Air flow rate [m3/min.]

BF: Bypass factor

EWB: Entering wet bulb temp. [°CWB]

EDB: Entering dry bulb temp. [°CDB]

TC: Total capacity cooling [kW]

SHC: Sensible heat capacity [kW]

PI: Power input [kW]

NOTES

1 Ratings shown are net capacities which include a deduction for indoor fan motor heat.

2 shows nominal (rated) capacities and power input.

3 TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation).

4 SHC is based on each EWB and EDB.SHC* = SHC correction for other dry bulb.

= 0.02 x AFR [m3/min.] x (1-BF) x (DB*-EDB)Add SHC* to SHC.

5 Capacities are based on the folowing conditions.Corresponding refrigerant piping length: 5m(7.5m at [AS/NZS3823.1])Level difference: 0m

6 Air flow rate (AFR) and Bypass factor (BF) are tabulated below.

7 Add the following corrections to power input at[AS/NZS3823.1] as shown below.

Indoor Outdoor temperature (°CDB)

EWB (°C)

EDB (°C)

20 25 30 32 35 40 46TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI

14.0 20.0 5.36 3.67 1.25 5.21 3.60 1.35 5.06 3.53 1.44 5.00 3.50 1.48 4.91 3.46 1.54 4.76 3.39 1.63 4.58 3.30 1.74

16.0 22.0 5.52 3.70 1.28 5.37 3.63 1.37 5.22 3.56 1.47 5.16 3.53 1.50 5.07 3.49 1.56 4.92 3.42 1.66 4.74 3.34 1.7718.0 25.0 5.67 3.73 1.30 5.52 3.66 1.40 5.37 3.59 1.49 5.31 3.57 1.53 5.22 3.52 1.59 5.07 3.45 1.68 4.89 3.37 1.80

19.0 27.0 5.75 3.75 1.32 5.60 3.68 1.41 5.45 3.61 1.51 5.39 3.58 1.54 5.30 3.54 1.80 5.15 3.47 1.70 4.97 3.39 1.81

22.0 30.0 5.98 3.80 1.35 5.83 3.73 1.45 5.68 3.66 1.54 5.62 3.63 1.58 5.53 3.59 1.64 5.38 3.52 1.73 5.20 3.44 1.8524.0 32.0 6.14 3.84 1.38 5.99 3.77 1.48 5.84 3.70 1.57 5.78 3.67 1.61 5.69 3.63 1.67 5.54 3.56 1.76 5.36 3.47 1.87

FTAFR 16.2

BF 0.27

Voltage PI [kW]

230 V +0.05

• Split Sky Air • Outdoor Units 12

Page 13: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

13

14

4 Capacity tables

4 - 1 Capacity tables

FT60CV1A9 + R60CV1A9

3D045960

Cooling capacity (50 Hz, 220-240 V)

SYMBOLS

AFR: Air flow rate [m3/min.]

BF: Bypass factor

EWB: Entering wet bulb temp. [°CWB]

EDB: Entering dry bulb temp. [°CDB]

TC: Total capacity cooling [kW]

SHC: Sensible heat capacity [kW]

PI: Power input [kW]

NOTES

1 Ratings shown are net capacities which include a deduction for indoor fan motor heat.

2 shows nominal (rated) capacities and power input.

3 TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation).

4 SHC is based on each EWB and EDB.SHC* = SHC correction for other dry bulb.

= 0.02 x AFR [m3/min.] x (1-BF) x (DB*-EDB)Add SHC* to SHC.

5 Capacities are based on the folowing conditions.Corresponding refrigerant piping length: 5m(7.5m at [AS/NZS3823.1])Level difference: 0m

6 Air flow rate (AFR) and Bypass factor (BF) are tabulated below.

7 Add the following corrections to power input at[AS/NZS3823.1] as shown below.

Indoor Outdoor temperature (°CDB)

EWB(°C)

EDB(°C)

20 25 30 32 35 40 46TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI

14.0 20.0 6.66 4.40 2.04 6.51 4.33 2.14 3.36 4.26 2.23 6.30 4.23 2.27 6.21 4.19 2.33 6.06 4.12 2.42 5.88 4.17 2.5316.0 22.0 6.82 4.43 2.07 6.67 4.36 2.16 6.52 4.29 2.26 6.46 4.26 2.29 6.37 4.22 2.35 6.22 4.15 2.45 6.04 4.20 2.5618.0 25.0 6.97 4.47 2.09 6.82 4.40 2.19 6.67 4.33 2.28 6.61 4.30 2.32 6.52 4.26 2.38 6.37 4.19 2.47 6.19 4.24 2.5919.0 27.0 7.05 4.48 2.11 6.90 4.41 2.20 6.75 4.34 2.30 6.69 4.32 2.33 6.60 4.27 2.39 6.45 4.20 2.49 6.27 4.25 2.6022.0 30.0 7.28 4.53 2.14 7.13 4.46 2.24 6.98 4.39 2.33 6.92 4.37 2.37 6.83 4.32 2.43 6.68 4.25 2.52 6.50 4.31 2.6424.0 32.0 7.44 4.57 2.17 7.29 4.50 2.27 7.14 4.43 2.36 7.08 4.40 2.40 6.99 4.36 2.46 6.84 4.29 2.55 6.66 4.34 2.66

FTAFR 17.5BF 0.23

Voltage PI [kW]230 V +0.07

• Split Sky Air • Outdoor Units

Page 14: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

15

• Outdoor Units • R-22 • R-C

5 Dimensional drawing & centre of gravity

5 - 1 Dimensional drawing

R25,35CV1A9

3D028041A

MINIMUM SPACE FOR AIR PASSAGE

Name plate

Wall height on air outlet side is less than 1200

Terminal strip with earth terminalWiring inlet

Drain outlet(I.D. ø 15.9 hose for connection)

4-holes for anchor bolts(M8 or M10)

Service port

Gas stop valve:Model R25: 9.5 CuT

Model R35: 12.7 CuTLiquid stop valveø 6.4 CuTIN CASE OF

REMOVING STOP VALVE COVER

• Split Sky Air • Outdoor Units 14

Page 15: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

15

15

5 Dimensional drawing & centre of gravity

5 - 1 Dimensional drawing

R50,60CV1A9

3D004856G

MINIMUM SPACE FOR AIR PASSAGE

Name plate

Earth terminal (M4) Terminal cover

Holes for anchor bolts(M8 or M10) 2-drain outlet

Power intake

Liquid stop valve

Gas pipe(ø 15.9 CuT)

Liquid pipe(ø 6.4 CuT)

Gas stop valve

Service port

Outdoor air thermostat

H A

1000 300

> 1000 600

• Split Sky Air • Outdoor Units

Page 16: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

16

• Outdoor Units • R-22 • R-C

6 Piping diagram

R25CV1A9

3D020878D

Field piping(6.4 CuT)

Outdoor unit

9.5 CuT

Heat exchanger

Capillary tube

Propellor fan

Accumulator

7.9 CuT

Field piping(9.5 CuT)

7.9 CuT

7.9 CuT7.9 CuT

7.9 CuT

7.9 CuT6.4 CuT

Compressor

7.9 CuT

9.5 CuT

7.9

CuT

9.5

CuT

Gas stop valve with service port

Liquid stop valve7.9 CuT

• Split Sky Air • Outdoor Units 16

Page 17: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

17

16

6 Piping diagram

R35CV1A9

3D020877C

Field piping(6.4 CuT)

Outdoor unit

12.7 CuT

Heat exchanger

Capillary tube

Propellor fan

Accumulator

7.9 CuT

Field piping(12.7 CuT)

7.9 CuT

7.9 CuT7.9 CuT

7.9 CuT

7.9 CuT 6.4 CuT

Compressor

7.9 CuT

12.7 CuT

7.9

CuT

9.5

CuT

Gas stop valve with service port

Liquid stop valve

• Split Sky Air • Outdoor Units

Page 18: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

16

• Outdoor Units • R-22 • R-C

6 Piping diagram

R50,60CV1A9

DW521-856J

Field piping(6.4 CuT)

Outdoor unit

Heat exchanger

Capillary tube

Propellor fan

Accumulator

Field pipingsee note 1

Compressor

Gas stop valve with service port

Liquid stop valve

NOTE

1 Field piping specifications are as shown below.

Model name A

R50R60 15.9 CuT

• Split Sky Air • Outdoor Units 18

Page 19: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

19

17

7 Wiring diagram

7 - 1 Wiring diagram

R25CV1A9

3D024713B

Power supply~50 Hz220V-240V

To indoor unit

LEGEND

C11R, C12R Running capacitorK1M Compressor relayL LiveN NeutralM1C Compressor motorTFU Thermal fuseF1U FuseM1F Fan motorQ1CL Overcurrent overload

protectorX1M, X2M Terminal strip

Protective earth

NOTES

1 Wiring diagram nameplate size: width 110 x length 70.2 Nameplate material: wood free tack paper.3 Coat the reverse side with pressure sensitive adhesive4 Refer to AS(Y)303002 unless otherwise specified.5 This drawing was drawn on CAD system.6 Make a slit on separate liner in vertical direction.

• Split Sky Air • Outdoor Units

Page 20: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

17

• Outdoor Units • R-22 • R-C

7 Wiring diagram

7 - 1 Wiring diagram

R35CV1A9

3D024714B

Power supply~50 Hz220V-240V

To indoor unit

LEGEND

C11R, C12R Running capacitorK1M Compressor relayL LiveN NeutralM1C Compressor motorF1U FuseM1F Fan motorQ1L Overlead protectorX1M, X2M Terminal stripTFU Thermal fuse

Protective earth

NOTES

1 Wiring diagram nameplate size: width 110 x length 70.2 Nameplate material: wood free tack paper.3 Coat the reverse side with pressure sensitive adhesive4 Refer to AS(Y)303002 unless otherwise specified.5 This drawing was drawn on CAD system.6 Make a slit on separate liner in vertical direction.

• Split Sky Air • Outdoor Units 20

Page 21: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

21

17

7 Wiring diagram

7 - 1 Wiring diagram

R50CV1A9

3D045730

Power supply~50 Hz220V-240V

indoor Field wiring

outdoor

LEGEND

C11R, C12R Running capacitorF1S Surge arresterF1U FuseK1M Compressor relayL LiveM1C Compressor motorM1F Fan motorN NeutralQ1L Overload protectorX11A ConnectorX1M Terminal strip

Protective earth

NOTES

1 Refer to the nameplate for the power requirements.2 Wiring diagram nameplate size: width 110 x length 70.3 Nameplate material: wood free tack paper.4 Coat the reverse side with pressure sensitive adhesive.5 Refer to AS(Y)303002 unless otherwise specified.6 This drawing was drawn on CAD system.7 Make a slit on separate liner in vertical direction.

• Split Sky Air • Outdoor Units

Page 22: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

17

• Outdoor Units • R-22 • R-C

7 Wiring diagram

7 - 1 Wiring diagram

R60CV1A9

3D045733

Power supply~50 Hz220V-240V

indoor Field wiring

outdoor

LEGEND

C11R, C12R Running capacitorF1S Surge arresterF1U FuseK1M Compressor relayL LiveM1C Compressor motorM1F Fan motorN NeutralS1T ThermostatX11A ConnectorX1M Terminal strip

Protective earth

NOTES

1 Refer to the nameplate for the power requirements.2 Wiring diagram nameplate size: width 110 x length 70.3 Nameplate material: wood free tack paper.4 Coat the reverse side with pressure sensitive adhesive.5 Refer to AS(Y)303002 unless otherwise specified.6 This drawing was drawn on CAD system.7 Make a slit on separate liner in vertical direction.

• Split Sky Air • Outdoor Units 22

Page 23: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

23

18

8 Sound data

8 - 1 Sound pressure spectrum

R25CV1A9

4D029157A

Octave band center frequency (Hz)

Octa

ve b

and

soun

d pr

essu

re le

vel (

dB) (

0 dB

= 0

.000

2 μb

ar)

Location of microphone

NOTES

1 Measurement was taken in an anechoic room.2 The operation noise measuring method is in accordance

with JISC9612.3 Operating conditions:

Power source = 220-240 V, 50 Hzo------o H (A = 48) and o- - - -o L (A = 46)

4 Operation noise differs with operation and ambient conditions.

Approximate threshold hearing for continuous noise

R35CV1A9

4D000697C

Octave band center frequency (Hz)

Octa

ve b

and

soun

d pr

essu

re le

vel (

dB) (

0 dB

= 0

.000

2 μb

ar)

Location of microphone

NOTES

1 Measurement was taken in an anechoic room.2 The operation noise measuring method is in accordance

with JISC9612.3 Operating conditions:

Power source = 220-230V (L) or 240 V (H), 50 Hzo------o H (A = 49) and o- - - -o L (A = 48)

4 Operation noise differs with operation and ambient conditions.

Approximate threshold hearing for continuous noise

R50,60CV1A9

DW527-217F

Octave band center frequency (Hz)

Octa

ve b

and

soun

d pr

essu

re le

vel (

dB) (

0 dB

= 0

.000

2 μb

ar)

Location of microphone

NOTES

1 Measurement was taken in an anechoic room.2 The operation noise measuring method is in accordance

with JISC9612.3 Operating conditions:

Power source = 220-230V (L) or 240 V (H), 50 Hzo------o H (A = 55) and o- - - -o L (A = 54)

4 Operation noise differs with operation and ambient conditions.

Approximate threshold hearing for continuous noise

• Split Sky Air • Outdoor Units

Page 24: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

19

• Outdoor Units • R-22 • R-C

9 Operation range

R25,35,50,60CV1A9

4D000888K

Outd

oor t

emp.

(°CD

B)

Indoor temp. (°CWB)

Cont

inuo

us o

pera

ton

Pull)

dow

n pe

riod

NOTES

The graph is based on the following conditions:

1 Equivalent piping length: 5m

2 Level difference: 0m

3 Air flow rate: high

• Split Sky Air • Outdoor Units 24

Page 25: technical databeeclimat.com/upload/file/R-C.pdf · current (RLA) Cooling (A) A 3.78 5.38 7.12 10.70 Starting current (cooling/ heating) A 20.0 27.0 33.5 58.0 Voltage range Minimum

• Outdoor Units • R-22 • R-C

25

19

• Split Sky Air • Outdoor Units