Petrolux® III
Thermal Performance Data
Family Source1598 Ambient
(°C)844 Ambient
(°C)
SupplyWire(°C)
Class I Div 2 Class II Div 1
Class III
SimultaneousPresence
Class I Div 2Class II Div 1
Class IZone 2
Watt Type PD/WL CE PD/WL CE Groups T Rating Groups T Rating nA nR
P3S
42 CFL 55 55 55 55 90 A, B, C, D T3 E, F, G T4 T1 T650 HPS 60** 55** 55* 55 90 A, B, C, D T3 E, F, G T4A T1 T650 MH 55 55 55 55 90 A, B, C, D T2D E, F, G T4 T1 T555 QL 45 45 40 40 90 A, B, C, D T3C E, F, G T4A T1 —70 HPS 60** 55** 55* 55 90 A, B, C, D T2C E, F, G T4A T2C T470 MH 55 55 55 55 90 A, B, C, D T2D E, F, G T5 T2B T4100 HPS 60** 55** 55* 55 90 A, B, C, D T2A E, F, G T4A T2B T4100 MH 55 55 55 55 90 A, B, C, D T2B E, F, G T4 T1 T4150 HPS 60** 50† 55* 40 90 A, B, C, D 325 E, F, G T4 T2 T4150 MH 55 50† 55 40 90 A, B, C, D 350 (325 for CE) E, F, G T4 350 (325 for CE) T4150 MHE 40 40 40 40 90 A, B, C, D T1 E, F, G T4 T1 T5
P3M
42 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T655 QL 40 40 40 40 90 A, B, C, D T3C E, F, G T4 T2A —57 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T650 HPS 55 55 55 55 90 A, B, C, D T3C E, F, G T4 T2A T570 HPS 55 55 55 55 90 A, B, C, D T3A E, F, G T5 T3A T470 MH 55 55 55 55 90 A, B, C, D T2C E, F, G T4 T2A T470 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T685 QL 40 40 40 40 90 A, B, C, D T3C E, F, G T4 T2A —100 HPS 55 55 55 55 90 A, B, C, D T2D E, F, G T4A T3 T3100 MH 55 55 55 55 90 A, B, C, D T2A E, F, G T4A T2B T3150 HPS 55 55 55 55 90 A, B, C, D T2B E, F, G T4A T2B T3150 MH 55 55 55 55 90 A, B, C, D 350 E, F, G T4 T2A T4150 MHE 40 40 40 40 90 A, B, C, D 325 E, F, G T4 T2 T4175 PMH 55 55 55 55 90 A, B, C, D T2A E, F, G T4 T2A T4
* UL844 Ambient Temperature is 40°C when fusing is ordered as an option** UL1598 Ambient Temperature is 50°C when fusing is ordered as an option† UL1598 Ambient Temperature is 45°C when fusing is ordered as an option