INTERIOR INSTALLATION UNISTRUT SPACING VARIES DEPENDING ON BAFFLE CURVE CONFIGURATION. 4'-0" TYP., 6'-0" MAX. 2'-0" MAX BAFFLE OVERHANG, TYP. 6" BAFFLE SPACING SHOWN, ACTUAL CAN VARY, TYP. 1 5 8 " 4" 6 3 8 " HANGER BRACKET 1-1/2" X 6-3/8" BEAM 1-5/8" X 1-5/8" UNISTRUT P1000 - 12 GA. STEEL PRIMARY CHANNEL TYPICAL SYSTEM SECTION SCALE: 3" = 1'-0" 1 1 2 " VARIES TYPICAL ELEVATION SCALE: NOT TO SCALE 1/4"-20 THREADED ROD AND ATTACHMENT TO UNISTRUT BY OTHERS, TYP. BAFFLE END CAP SEE DETAIL A1.5 8'-0" VAULT RADIUS SHOWN BAFFLE SPECIFICATIONS SEE DETAIL A1.1 SUSPENSION SPECIFICATIONS SEE DETAIL A1.2 HANGER BRACKET SEE DETAIL A1.3 BAFFLE SPLICE CONDITIONS SEE DETAIL A1.4 THREADED ROD BY OTHERS SEE DETAIL A1.2 1-5/8" X 1-5/8" UNISTRUT P1000 - 12 GA. STEEL PRIMARY CHANNEL SEE DETAIL A1.2 8'-0" VALLEY RADIUS SHOWN 5015 Oakbrook Parkway, Suite 100 Norcross, GA 30093 O 800.366.4327 F 770.806.0214 CTSpecialtyCeilings.com All rights reserved. This drawing is the property of CertainTeed Ceilings Corporation. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. SPECIFICATIONS (unless noted otherwise) MATERIAL: EXTRUDED ALUMINUM ALLOY 6063-T5 FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH PERFORATION: NOT AVAILABLE OVERALL ISOMETRIC VIEW PROJECT: HIGH PROFILE SERIES VERTICALLY CURVED PRODUCT SPECIFICATIONS DRAWING NUMBER: HPS-VCURVE-A1.0 SCALE: AS SHOWN DRAWN BY: HD ENGINEERING DATE: 12/7/18

Transcript of SUSPENSION SPECIFICATIONS UNISTRUT SPACING VARIES ... · insert end cap into baffle and ensure end...

Page 1: SUSPENSION SPECIFICATIONS UNISTRUT SPACING VARIES ... · insert end cap into baffle and ensure end cap bracket slides into suspension slot at top of baffle. metal end cap painted,

INTERIOR INSTALLATION

UNISTRUT SPACING VARIES DEPENDING

ON BAFFLE CURVE CONFIGURATION.

4'-0" TYP., 6'-0" MAX.

2'-0" MAX BAFFLE OVERHANG, TYP.6" BAFFLE SPACING SHOWN,

ACTUAL CAN VARY, TYP.

15 8"4"

63 8"

HANGER BRACKET

1-1/2" X 6-3/8"BEAM

1-5/8" X 1-5/8" UNISTRUT P1000 -12 GA. STEEL PRIMARY CHANNEL

TYPICAL SYSTEM SECTIONSCALE: 3" = 1'-0"

112"

VARI

ES

TYPICAL ELEVATIONSCALE: NOT TO SCALE

1/4"-20 THREADED ROD AND ATTACHMENTTO UNISTRUT BY OTHERS, TYP.

BAFFLE END CAPSEE DETAIL A1.5

8'-0"

VAU

LT R

ADIU

S SHO

WN

BAFFLE SPECIFICATIONSSEE DETAIL A1.1

SUSPENSION SPECIFICATIONSSEE DETAIL A1.2

HANGER BRACKETSEE DETAIL A1.3

BAFFLE SPLICE CONDITIONSSEE DETAIL A1.4

THREADED ROD BY OTHERSSEE DETAIL A1.2

1-5/8" X 1-5/8" UNISTRUT P1000 -12 GA. STEEL PRIMARY CHANNELSEE DETAIL A1.2

8'-0"

VAL

LEY

RAD

IUS S

HOW

N

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: EXTRUDED ALUMINUM ALLOY 6063-T5

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH

PERFORATION: NOT AVAILABLE

OVERALL ISOMETRIC VIEW

PROJECT: HIGH PROFILE SERIES VERTICALLY CURVED PRODUCT SPECIFICATIONS

DRAWING NUMBER: HPS-VCURVE-A1.0

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 12/7/18

Page 2: SUSPENSION SPECIFICATIONS UNISTRUT SPACING VARIES ... · insert end cap into baffle and ensure end cap bracket slides into suspension slot at top of baffle. metal end cap painted,

48" M

IN V

ALLE

Y RA

DIU

S*

48" M

IN V

AULT

RAD

IUS*

BAFFLE GEOMETRY - SIDE VIEWSCALE: NOT TO SCALE

CONTINUOUS BAFFLESMUST BE TANGENT

4'-0" MIN - 20'-0" MAXRECOMMENDED LENGTH**

SEAMLESS STRAIGHT-TO-CURVECONFIGURATIONS AVAILABLE(MUST BE TANGENT)

BAFFLE MATERIAL

EXTRUDED ALUMINUM ALLOY 6063-T5

BAFFLE FINISHES

PAINTED & POWDER COATED

DECORATED WOOD FINISH (POWDER COATED)

PERFORATIONS

BAFFLES CANNOT BE PERFORATED

*48" MIN RADIUS

**MAX LENGTH MAY BE LIMITED DUE TO RADIUS

1-1/2" X 6-3/8"BEAM

63 8"112"

BAFFLE PROFILESCALE: 3" = 1'-0"

63 8" B

AFFLE

HEIGHT

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: EXTRUDED ALUMINUM ALLOY 6063-T5

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH

PERFORATION: NOT AVAILABLE

BAFFLE SPECIFICATIONS

PROJECT: HIGH PROFILE SERIES VERTICALLY CURVED PRODUCT SPECIFICATIONS

DRAWING NUMBER: HPS-VCURVE-A1.1

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 12/7/18

Page 3: SUSPENSION SPECIFICATIONS UNISTRUT SPACING VARIES ... · insert end cap into baffle and ensure end cap bracket slides into suspension slot at top of baffle. metal end cap painted,

15 8"4"

63 8" 112"

1'-0" MAX UNISTRUTOVERHANG, TYP. 4'-0" MAX VERTICAL SUPPORT SPACING, TYP.

NOTE:THREADED ROD ATTACHMENT TO UNISTRUT AND STRUCTUREABOVE DESIGNED AND PROVIDED BY OTHERS.

SEISMIC DESIGN:SYSTEM COMPLIES WITH ASCE 7-10 SECTION 13.5.6 AND13.5.6.2.2. BAFFLES WITH 1/4" DIA. HANGERS DESIGNED ASPENDULUMS. MAXIMUM Ss = 3.73, MEETING SEISMIC ZONED-E-F REQUIREMENTS. UNISTRUT FRAMING TO BE BRACED INACCORDANCE WITH LOCAL CODE REQUIREMENTS. CROSSSTRUTS AT UNISTRUT FRAMING WITH SPLAYED WIRES ANDCOMPRESSION POST BY OTHERS.

1-5/8" X 1-5/8" UNISTRUT P1000 -12 GA. STEEL PRIMARY CHANNEL

4'-0" MAX VERTICAL

SUPPORT SPACING, TYP.

1'-0" MAX UNISTRUT

OVERHANG, TYP.

1-5/8" X 1-5/8" UNISTRUT P1000 -12 GA. STEEL PRIMARY CHANNEL

HANGER BRACKET AT ALL BAFFLE/UNISTRUT INTERSECTIONS, TYP.

THREADED ROD BY OTHERS, TYP.

1-1/2" X 6-3/8" BEAM WITH 8'-0"VAULT RADIUS SHOWN

1/4"-20 THREADED ROD AND ATTACHMENTTO UNISTRUT BY OTHERS, TYP.

UNISTRUT SPACING VARIES DEPENDING

ON BAFFLE CURVE CONFIGURATION.

4'-0" TYP., 6'-0" MAX.

2'-0" MAX

BAFFLE OVERHANG, TYP.

UNISTRUT SPACING VARIES DEPENDING ONBAFFLE CURVE CONFIGURATION. 4'-0" TYP., 6'-0" MAX.

2'-0" MAX BAFFLEOVERHANG, TYP.

1/4"-20 THREADED ROD AND ATTACHMENTTO UNISTRUT BY OTHERS, TYP.

HANGER BRACKET

THREADED ROD BYOTHERS, TYP. 1-5/8" X 1-5/8" UNISTRUT P1000 -

12 GA. STEEL PRIMARY CHANNEL

TYPICAL SECTIONSSCALE: 3" = 1'-0"

1-1/2" X 6-3/8" BEAM WITH 8'-0"VAULT RADIUS SHOWN

1-1/2" X 6-3/8" BEAM

HANGERBRACKET

1/4"-20 THREADED ROD AND ATTACHMENTTO UNISTRUT BY OTHERS, TYP.

THREADED ROD BY OTHERS, TYP.

412" CLEAR, TYP.

6" BAFFLE SPACING SHOWN,

ACTUAL CAN VARY, TYP.

6" SHOWN,ACTUAL CANVARY, TYP.

BEAM END CAP

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: EXTRUDED ALUMINUM ALLOY 6063-T5

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH

PERFORATION: NOT AVAILABLE

SUSPENSION SPECIFICATIONS

PROJECT: HIGH PROFILE SERIES VERTICALLY CURVED PRODUCT SPECIFICATIONS

DRAWING NUMBER: HPS-VCURVE-A1.2

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 12/7/18

Page 4: SUSPENSION SPECIFICATIONS UNISTRUT SPACING VARIES ... · insert end cap into baffle and ensure end cap bracket slides into suspension slot at top of baffle. metal end cap painted,

MOUNTING BRACKET

SET SCREW

PIN

1/4" DIA. HOLE

ROD END BOLT

COUPLING NUT FOR1/4"-20 THREADEDROD

1

1 SLIDE MOUNTING BRACKET INTO SUSPENSIONSLOT OF BAFFLE.

2 LIFT BAFFLE ASSEMBLY AND SECURE 1/4"-20THREADED ROD (BY OTHERS) TO COUPLER.

2

3

4

3 TIGHTEN SET SCREW FOR ALIGNMENT.

4 ONCE IN FINAL POSITION, SECURE BRACKETWITH #12 TEK SCREW (BY OTHERS).

21/4"-20 THREADED RODBY OTHERS

HANGER BRACKET

#12 TEK SCREWBY OTHERS

1-1/2" X 6-3/8" BEAM

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: EXTRUDED ALUMINUM ALLOY 6063-T5

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH

PERFORATION: NOT AVAILABLE

HANGER BRACKET INSTALLATION

PROJECT: HIGH PROFILE SERIES VERTICALLY CURVED PRODUCT SPECIFICATIONS

DRAWING NUMBER: HPS-VCURVE-A1.3

SCALE: NOT TO SCALE

DRAWN BY: HD ENGINEERING

DATE: 12/7/18

Page 5: SUSPENSION SPECIFICATIONS UNISTRUT SPACING VARIES ... · insert end cap into baffle and ensure end cap bracket slides into suspension slot at top of baffle. metal end cap painted,

*VERTICAL SUPPORT OMITTED FOR CLARITY

1 INSERT CURVED BAFFLE SPLICE HALFWAY INTO BAFFLE.NOTE ORIENTATION OF TABS FOR FASTENER ATTACHMENT.

2 SECURE WITH TWO (2) MIN #8 TEK SCREWS (BY OTHERS).

3 SLIDE SECOND BAFFLE OVER SPLICE AND TIGHT AGAINSTFIRST BAFFLE. ENSURE FINISHED SEAM IS ALIGNED ANDFLUSH ON ALL SIDES.

4 SECURE REMAINING SIDE WITH TWO (2) MIN #8 TEKSCREWS.

4

2

3

1CURVED BAFFLE SPLICE

DIMENSION NOT TO EXCEED

1/2 OF UNISTRUT SPACING

DIMENSION NOT TO EXCEED

1/2 OF UNISTRUT SPACING

U

NISTRUT SPACING VARIES DEPENDING

ON BAFFLE CURVE CONFIGURATION.

4'-0" TYP., 6'-0" MAX.

NOTE:DUE TO BAFFLE SPLICE FASTENERS,HANGER BRACKETS WILL NOT FIT ATSPLICE LOCATIONS.

BAFFLE SPLICE LOCATION

1-5/8" X 1-5/8" UNISTRUT P1000 -12 GA. STEEL PRIMARY CHANNEL

MIN TWO (2) HANGER BRACKETSREQUIRED PER BAFFLE, TYP.

1-1/2" X 6-3/8" BEAM

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: EXTRUDED ALUMINUM ALLOY 6063-T5

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH

PERFORATION: NOT AVAILABLE

BAFFLE SPLICE INSTALLATION

PROJECT: HIGH PROFILE SERIES VERTICALLY CURVED PRODUCT SPECIFICATIONS

DRAWING NUMBER: HPS-VCURVE-A1.4

SCALE: NOT TO SCALE

DRAWN BY: HD ENGINEERING

DATE: 12/7/18

Page 6: SUSPENSION SPECIFICATIONS UNISTRUT SPACING VARIES ... · insert end cap into baffle and ensure end cap bracket slides into suspension slot at top of baffle. metal end cap painted,

1/8"

1 APPLY CONSTRUCTIONADHESIVE ON 3 SIDES SHOWN.

2

3

INSERT END CAP INTO BAFFLEAND ENSURE END CAP BRACKETSLIDES INTO SUSPENSION SLOTAT TOP OF BAFFLE.

METAL END CAP

PAINTED, POWDER COATED, &DECORATED WOOD FINISHES

APPLY EVEN PRESSURE TO SETEND CAP ALL THE WAY INTOBAFFLE AND TIGHTEN SETSCREW TO SECURE END CAP.

*1-1/2" X 6-3/8" BEAM PROFILE SHOWN, ALL PROFILES SIMILAR

NOTE:END CAPS ONLY AVAILABLE FORSQUARE CUT BAFFLE ENDS.

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: EXTRUDED ALUMINUM ALLOY 6063-T5

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH

PERFORATION: NOT AVAILABLE

END CAP INSTALLATION

PROJECT: HIGH PROFILE SERIES VERTICALLY CURVED PRODUCT SPECIFICATIONS

DRAWING NUMBER: HPS-VCURVE-A1.5

SCALE: NOT TO SCALE

DRAWN BY: HD ENGINEERING

DATE: 12/7/18