StorCase ® Technology InfoStation ® 12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID External Expansion Chassis User's Guide

Transcript of StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID...

Page 1: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

StorCase® Technology

InfoStation®

12-Bay Ultra320-to-Serial ATA RAID12-Bay FC-to-Serial ATA RAIDExternal Expansion Chassis

User's Guide

Page 2: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

i

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

StorCase Technology, Inc.17600 Newhope Street

Fountain Valley, CA 92708-9885Phone (714) 438-1850 Fax (714) 438-1847

StorCase® Technology

InfoStation®

12-Bay Ultra320-to-Serial ATA12-Bay FC-to-Serial ATA

RAID External Expansion Chassis

User's Guide

Part No. D89-0000-0249 D00 February 2006

Page 3: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

ii

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

LIMITED WARRANTY

STORCASE TECHNOLOGY, Incorporated (“StorCase”) warrants that its products will be freefrom defects in material and workmanship, subject to the conditions and limitations set forthbelow. StorCase will, at its option, either repair or replace any part of its product that provesdefective by reason of improper workmanship or materials. Repair parts or replacementproducts will be provided by StorCase on an exchange basis, and will be either new orreconditioned to be functionally equivalent to new.

This warranty does not cover any product damage that results from accident, abuse, misuse,natural or personal disaster, external power surge or failure, or any unauthorized disassem-bly, repair or modification. StorCase will not be responsible for any software, firmware or othercustomer data stored within, or interfacing with a StorCase product.

Duration of Warranty

Seven-Year Warranty: The following StorCase products are covered by this warranty for aperiod of seven (7) years from the original date of purchase from StorCase or its authorizedresellers: all Data Express® removable device enclosures and all Data Silo®, Data Stacker® andInfoStation® external expansion chassis, except for those components integrated into orpurchased separately for use with these products which are identified and covered by the three-year or hard drive warranties described below. All StorCase interface cables and otheraccessories specifically intended for use with the StorCase products identified above are alsocovered by this (7) year warranty.

Three-Year Warranty: The following components integrated into or purchased separately foruse with StorCase Data Express, Data Silo, Data Stacker and/or InfoStation products are subjectto warranty for a period of three (3) years from the original date of purchase from StorCase orits authorized resellers: all RAID controllers, power supplies, fans and blowers.

Two-Year Warranty: The following StorCase products are covered by this warranty for aperiod of two (2) years from the original date of purchase from StorCase or its authorizedresellers: all Rhino®JR fixed external expansion chassis (model types “FJR”) and all RhinoJRremovable device enclosures (model types “RJR”).

One-Year Warranty: All StorCase products identified as Reconditioned or “Special Inventory”are covered by this warranty for a period of one (1) year from the original date of purchase fromStorCase or its authorized resellers. Reconditioned products may only be exchanged forreconditioned products.

Hard Disk Drive Warranty: All hard disk drives purchased from StorCase or through itsauthorized resellers, whether purchased separately or integrated into StorCase products, aresubject to the warranty terms and conditions provided by the drive manufacturer.

Third Party Software Warranty: All third party software purchased from StorCase for usewith and/or as part of StorCase products is subject to the warranty terms and conditionsprovided by the software manufacturer.

Page 4: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

iii

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Warranty Claim Requirements

To obtain warranty service, the defective product must be returned to your local authorizedStorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factoryservice center.

For defective products returned directly to StorCase, a Return Material Authorization (“RMA”)number must be obtained by calling StorCase Customer Service at (714) 445-3455. The RMAnumber must be prominently displayed on the outside of the return package. Shipments mustbe freight-prepaid and insured, and must include the product serial number, a detaileddescription of the problem experienced, and proof of the original retail purchase date. Productsmust be properly packaged to prevent damage in transit. Damage resulting from improperpackaging will not be covered by this warranty. The StorCase factory service center is locatedat 17650 Newhope Street, Receiving Dock, Gate #4, Fountain Valley, CA 92780, U.S.A.

Free Technical Support

StorCase provides free technical support. If you experience any difficulty during theinstallation or subsequent use of a StorCase product, please contact StorCase’s TechnicalSupport Department prior to servicing your system. This warranty covers only repair orreplacement of defective StorCase products, as described above. StorCase is not liable for,and does not cover under warranty, any costs associated with servicing and/or installationof StorCase products.

StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888)435-5460 (U.S. and Canada only). StorCase European Technical Support can be reached inthe U.K. at +44 (0) 1932 738900.

Disclaimers

The foregoing is the complete warranty for the products identified above andsupersedes all other warranties and representations, whether oral or written.StorCase expressly disclaims all warranties for the identified products, which arenot stated herein, including, to the extent permitted by applicable law, any impliedwarranty of merchantability or fitness for a particular purpose. In no event willStorCase be liable to the purchaser, or to any user of a StorCase product, for anydamages, expenses, lost revenues, lost savings, lost profits, or any otherincidental or consequential damages arising from the purchase, use or inabilityto use a StorCase product, even if StorCase has been advised of the possibilityof such damages.

Copyright © 2004 StorCase Technology. All rights reserved. All registeredtrademarks are the property of StorCase Technology. All other logos and trademarksare properties of their respective companies.

Page 5: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

iv

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Declaration of Conformity

Company Name:

Corporate Office Address:

Manufacturing Address:

Product Name:

Model Number:

Conforms to the following standards:EMC Directives:(89/336/EEC)

Low Voltage Directive:(73/23/EEC)

Safety Standards:CSA (NRTL/C)

TUV

EMI Standards:

EMC Standards:

Year of Manufacture:

Signature:___________________Full name: Dieter PaulPosition: President

StorCase Technology, Inc.

17600 Newhope StreetFountain Valley, CA 92708

17600 Newhope StreetFountain Valley, CA 92708

InfoStation 12-Bay SCSI-to-SATA RAID ChassisInfoStation 12-Bay FC-to-SATA RAID Chassis

S10B100, S10J100, S10H104, S10H105, S10H108,S10H112, S10K102, S10K104

ITE Emission- EN 55022: 1998- EN 61000-3-2 Harmonic Current- EN 61000-3-3 Voltage Fluctuations and FlickerEN 55024: 1998 ITE Immunity- IEC 61000-4-2 - IEC 61000-4-5- IEC 61000-4-3 - IEC 61000-4-6- IEC 61000-4-4 - IEC 61000-4-8

- IEC 61000-4-11EN 60950

CAN/CSA-C22.2 No. 60950UL 60950, Third Edition

EN 60950: 2000

FCC Part 15, Class A

AS/NSZ 3548 Information Technology EquipmentSupplier's Code Number N10664

2004

Page 6: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

v

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Federal Communications Commission (FCC) Statement

RADIO FREQUENCY INTERFERENCE STATEMENT

You are cautioned that changes or modifications not expressly approved by the partyresponsible for compliance could void your authority to operate that equipment.

This device complies with part 15 of the FCC rules. Operation is subject to the following twoconditions: (1) This device may not cause harmful interference, and (2) This device mustaccept any interference received, including interference that may cause undesired operation.

Important Safety Instructions

1. Read all these instructions.

2. Save these instructions for later use.

3. Follow all warnings and instructions marked on the product.

4. Do not use this product near water.

5. This product should be operated from the type of power source indicated on themarking label. If you are not sure of the type of power available, consult your dealeror local power company.

6. Do not attempt to service this product yourself, as opening or removing covers mayexpose you to dangerous voltage points or other risk. Refer all servicing to servicepersonnel.

Wichtige Sicherheitshinweise

1. Diese Hinweise sollten vollständig durchgelesen werden.

2. Diese Hinweise für einen späteren Gebrauch aufbewahren.

3. Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.

4. Das Gerät nicht in der Nähe von Wasser verwenden.

5. Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragenüber die Art der Netzspannung sollte der Händler oder dasEnergieversorgungsunternehmen zu rate gezogen werden.

6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existierengefährliche elektrische Spannugen. Nicht das Gehäuse öffnen.

7. Wartungsarbeiten nur von qualifiziertern Kundendienstpersonal ausführen laßen.

Page 7: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

vi

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Table of Contents

INTRODUCTION ..................................................................................................................... 1Packaging Information .................................................................................................. 1Serial Number ................................................................................................................ 1General Description ...................................................................................................... 2

Front Panel ............................................................................................................ 5Rear Panel ............................................................................................................. 6

LED Indicator and User Interface Panel ...................................................................... 8LED Indicator/UI Panel Components .................................................................... 8Drive Carrier Interface Panel ............................................................................... 9Inserting a Drice Carrier (with Drive Installed) ................................................. 10Removing a Drive Carrier (with Drive Installed) ............................................... 10Configuring Device and Chassis Settings ........................................................ 10

TYPICAL SCSI CHANNEL CONFIGURATION ..................................................................... 11TYPICAL FIBRE CHANNEL CONFIGURATION .................................................................... 12

RAID CONTROLLER CONFIGURATION .............................................................................. 14RAID Management Connection .................................................................................. 14Configuring the RAID Controller ................................................................................. 16

RAID Configuration via Data Master GUI ................................................................... 17Data Master Connection ..................................................................................... 17Quick RAID Setup ............................................................................................... 22Customized RAID Setup ..................................................................................... 24Partitions ............................................................................................................. 26

Partitions Greater than 2TB ....................................................................... 26Setting Up Multiple Partitions ...................................................................... 27

LUN Mapping ....................................................................................................... 32Deleting an Array ............................................................................................... 35

RAID Configuration via HyperTerminal ...................................................................... 36HyperTerminal Connection ................................................................................. 36

To Find HyperTerminal in Windows ........................................................... 36Settings ....................................................................................................... 36Selecting Menu Options ............................................................................. 38

Quick RAID Setup ............................................................................................... 39Customized RAID Setup ..................................................................................... 40Partitions ............................................................................................................. 42

Partitions Greater than 2TB ....................................................................... 42Viewing Default Partition Configuration .................................................... 42Setting Up Multiple Partitions ...................................................................... 43

LUN Mapping ....................................................................................................... 46Deleting an Array ............................................................................................... 49

Page 8: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

vii

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Configuration via InfoStation RAID Control Panel ............................................ 50RAID Control Panel ............................................................................................. 50

LEDs ................................................................................................................ 51Control Panel Buttons ..................................................................................... 51

Operation Mode .................................................................................................. 52

Mode Operation .................................................................................................. 53Self-Diagnostic Mode ..................................................................................... 53Configuration Mode ........................................................................................ 53Entering a Password ..................................................................................... 53

Main Menu Options ............................................................................................. 54Quick RAID Setup ............................................................................................... 55Customized RAID Setup ..................................................................................... 56Partitions ............................................................................................................. 58

Partitions Greater than 2TB ....................................................................... 58Setting Up Multiple Partitions ...................................................................... 58

LUN Mapping ....................................................................................................... 60Deleting an Array ............................................................................................... 61

RAID Controller Configuration Overview .................................................................. 621 RAID Params ................................................................................................... 62

1.1 Array 1 .................................................................................................... 631.1.1 Reconfigure RAID ............................................................................ 631.1.2 RAID Level ........................................................................................ 631.1.3 Disk Number ..................................................................................... 631.1.4 Slice .................................................................................................. 64

1.2 - 1.8 Arrays 2-8 ...................................................................................... 641.9 Stripe Size ............................................................................................... 641.A Write Buffer ............................................................................................ 651.B Performance ........................................................................................... 65

Array Management ............................................................................................. 66RAID Levels .................................................................................................... 66

2 SCSI Params (SCSI-to-SATA version only) ................................................. 672.1 Primary SCSI ............................................................................................ 67

2.1.1 Set SCSI ID ....................................................................................... 672.1.2 Speed ............................................................................................... 672.1.3 Wide .................................................................................................. 672.1.4 LUN Map ........................................................................................... 682.1.5 QAS .................................................................................................. 68

2.2 Secondary SCSI ...................................................................................... 68

2 Fibre Params (FC-to-SATA version only) ..................................................... 692.1 Primary FC ............................................................................................... 69

2.1.1 Enable Hard Loop ID ........................................................................ 692.1.2 Set Hard Loop ID .............................................................................. 692.1.3 Set Connection Mode ...................................................................... 702.1.4 Set Data Rate ................................................................................... 702.1.5 LUN Map ........................................................................................... 70

2.2 Secondary FC ......................................................................................... 70

Page 9: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

viii

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

2.3 SAN Mask ................................................................................................ 702.3.1 Visible for All Hosts ......................................................................... 70

2.3.1.1 Port 1 ......................................................................................... 702.3.1.2 Port 2 ......................................................................................... 70

2.3.2 SAN Mapping ................................................................................... 712.3.2.1 Port 1 ......................................................................................... 71

2.3.2.1.1 - 2.3.2.1.8 Select Host ...................................................... 712.3.2.2 Port 2 ......................................................................................... 71

2.3.2.2.1 - 2.3.2.2.8 Select Host ...................................................... 712.3.3 Edit WWN Table ................................................................................ 71

2.3.3.1 - 2.3.3.8 Select Host ................................................................. 712.3.4 View WWN Table ............................................................................. 712.3.5 View SAN Mapping .......................................................................... 72

2.3.5.1 Port 1 ......................................................................................... 722.3.5.2 Port 2 ......................................................................................... 72

3 RS232 Params ................................................................................................ 733.1 Modem Port .............................................................................................. 73

3.1.1 Baud Rate ......................................................................................... 733.1.2 Stop Bit ............................................................................................. 733.1.3 Data Bit ............................................................................................. 733.1.4 Parity ................................................................................................. 73

3.2 Terminal Port ............................................................................................ 743.2.1 Baud Rate ......................................................................................... 743.2.2 Stop Bit ............................................................................................. 743.2.3 Data Bit ............................................................................................. 743.2.4 Parity ................................................................................................. 74

4 System Params .............................................................................................. 754.1 Password Info ......................................................................................... 75

4.1.1 Password Check ............................................................................ 754.1.2 Set Password .................................................................................. 75

4.2 Pager Info ................................................................................................ 764.2.1 Paging ............................................................................................... 764.2.2 Pager 1 No. ...................................................................................... 774.2.3 Pager 2 No. ...................................................................................... 774.2.4 Code ................................................................................................. 774.2.5 Repeat .............................................................................................. 774.2.6 Interval .............................................................................................. 774.2.7 Page Now ......................................................................................... 77

4.3 Fax Info .................................................................................................... 784.3.1 Fax .................................................................................................... 784.3.2 Fax Class ......................................................................................... 784.3.3 Fax 1 No. .......................................................................................... 784.3.4 Fax 2 No. .......................................................................................... 794.3.5 Retry # .............................................................................................. 794.3.6 Fax Now ........................................................................................... 79

4.4 Company Info .......................................................................................... 794.4.1 String 1 ............................................................................................. 794.4.2 String 2 ............................................................................................. 80

Page 10: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

ix

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

4.5 Modem Init St ........................................................................................... 804.5.2 String 2 ............................................................................................. 80

5 NVRAM ........................................................................................................... 815.1 Update NVRAM ....................................................................................... 815.2 Erase NVRAM ......................................................................................... 815.3 Restart ..................................................................................................... 81

6 RAID Functions ............................................................................................... 826.1 Init Parity .................................................................................................. 836.2 Parity Check ............................................................................................ 836.3 Beeper ..................................................................................................... 836.4 Stop Modem ............................................................................................. 836.5 Add Disk .................................................................................................. 836.6 Remove Disk ............................................................................................ 836.7 Statistic .................................................................................................... 846.8 Expand Array .......................................................................................... 846.9 Update ROM ............................................................................................ 846.9 Log Event ................................................................................................. 84

6.9.1 Erase ................................................................................................ 846.9.2 Statistic ............................................................................................. 846.9.3 RTC ................................................................................................... 85

6.9.3.1 Set RTC ..................................................................................... 856.9.3.2 Show RTC ................................................................................. 85

6.A Utility ........................................................................................................ 856.A.1 Disk Self-Test (DST) ....................................................................... 85

6.A.1.1-6.A.1.2 Short Self Test or Extended Self Test ...................... 856.A.1.3 Stop DST .................................................................................. 86

6.A.2 Disk Scrubbing ................................................................................ 866.A.2.1 Overwrite Parity ...................................................................... 866.A.2.2 Scrub Mode .............................................................................. 86

6.A.2.2.1 Manual Scrubbing ............................................................. 866.A.2.2.2 Schedule Scrubbing ......................................................... 876.A.2.2.3 View Schedule ................................................................. 87

6.A.3 Disk Clone ........................................................................................ 876.A.3.1 Start Disk Clone ....................................................................... 87

6.A.3.1.1-6.A.3.1.2 Source Disk and Target Disk ........................... 886.A.3.1.3 Start Permanent Clone ...................................................... 886.A.3.1.4 Start Swap after Clone .................................................... 88

6.A.3.2 Stop Disk Clone ........................................................................ 886.A.3.3 Replace Source Disk ............................................................... 88

6.A.4 SMART ............................................................................................. 886.A.4.1 Test Disk SMART ..................................................................... 896.A.4.2 SMART Mode ............................................................................ 896.A.4.3 SMART Check Time ................................................................. 896.A.4.4 Bad Blocks ............................................................................... 89

6.A.4.4.1 View Statistics ................................................................. 896.A.4.4.2 Threshold for Clone .......................................................... 906.A.4.4.3 Threshold for Swap ......................................................... 90

6.B Update Rom ............................................................................................. 90

Page 11: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

x

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

APPENDICES........................................................................................................................ 91Appendix A - Specifications/Dimensions .................................................................. 92Appendix B - Optional Accessories .......................................................................... 97

Slide Rail Kit ......................................................................................................... 98RAID Controller Memory Modules ...................................................................... 99Optional Power Supply Module ........................................................................ 100Replacement Fan Module ................................................................................. 101Drive Carrier ...................................................................................................... 102SFP Module (For FC-to-SATA version only) ................................................... 102Carrying Case ................................................................................................... 103RAID Battery Backup Kit .................................................................................. 104InfoStation Monitoring Utility (InfoMon) ............................................................ 105

Appendix C - Troubleshooting ................................................................................. 106StorCase Technical Support ............................................................................ 106Setup Problems ................................................................................................. 106Operation Problems .......................................................................................... 107Remote Terminal Problems ............................................................................... 108Alert Message Problems .................................................................................. 108SCSI Problems .................................................................................................. 109Error Messages ................................................................................................ 110

Reader's Comments .......................................................................................................... 113

Page 12: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

xi

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

List of Figures

Figure 1: InfoStation 12-Bay RAID Chassis .................................................................. 4Figure 2: InfoStation Front Panel ................................................................................... 5Figure 3A: SCSI-to-SATA InfoStation Rear Panel .......................................................... 7Figure 3B: FC-to-SATA InfoStation Rear Panel .............................................................. 7Figure 4: UI Module ......................................................................................................... 8Figure 5: InfoStation Drive Carrier Interface ................................................................ 9Figure 6: Typical Dual SCSI Host Connection to InfoStation ...................................... 11Figure 7: FC Ports and LEDs ....................................................................................... 12Figure 8: Typical Dual FC Loops Connection to InfoStation ...................................... 13Figure 9: DB9 Port Location ......................................................................................... 15Figure 10A: Connection Name Setup Screen ................................................................. 17Figure 10B: Connection Screen ...................................................................................... 18Figure 10C: Location Type Setup Screen ....................................................................... 19Figure 10D: Serial Port Setup Screen ............................................................................. 19Figure 10E: Baud Rate Setup Screen ............................................................................. 20Figure 10F: Set Access Screen ..................................................................................... 20Figure 10G: Password Screen ........................................................................................ 21Figure 10H: Confirmation Screen .................................................................................... 21Figure 11: Data Master Quick Setup Screen ................................................................ 22Figure 12: Data Master RAID Creation Screen ............................................................. 23Figure 13: Data Master Create Array Option ................................................................ 24Figure 14: Data Master Create Array Screen .............................................................. 25Figure 15: Data Master Partitions Option ...................................................................... 27Figure 16: Data Master Create Partitions Screen ........................................................ 28Figure 17: Data Master Reconfigure Partitions Option ................................................. 29Figure 18A: Example of a RAID 0 Creation with 2.2TB Total Capacity ......................... 30Figure 18B: Example of a RAID 0 Creation with 2.2TB Total Capacity ......................... 31Figure 19: Data Master LUN Mapping Option ................................................................ 32Figure 20A: Example of One Array and One Partition .................................................... 33Figure 20B: Example of Two Arrays and Two Partitions .............................................. 34Figure 21A: HyperTerminal Connection Screen .............................................................. 37Figure 21B: Monitor Utility (HyperTerminal) Screen ....................................................... 37Figure 22: Example of a RAID 0 Creation with 2.2TB Total Capacity ......................... 45Figure 23: HyperTerminal LUN Map Option ................................................................... 47Figure 24: Example of One Array and Two Slices ...................................................... 48Figure 25: LCD Display and Control Panel .................................................................... 50

Figure A-1: InfoStation Physical Dimensions .................................................................. 97Figure B-1: Rack Mount Slide Rail Kit .............................................................................. 98Figure B-2: RAID Controller Memory Module .................................................................. 99Figure B-3: Power Supply Module ................................................................................ 100Figure B-4: Fan Module ................................................................................................. 101Figure B-5: Drive Carrier ............................................................................................... 102Figure B-6: LC (optical) SFP Module ............................................................................. 102Figure B-7: Carrying Case ............................................................................................. 103Figure B-8: RAID Battery Backup Kit ............................................................................ 104

Page 13: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

xii

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

NOTICE: This User's Guide is subject to periodic updates without notice. While reason-able efforts have been made to ensure accuracy of this document, StorcaseTechnology, Inc. assumes no liability resulting from errors or omissions in thispublication, or from the use of the information contained herein.

Please check the StorCase web site at http://www.storcase.com or contactyour StorCase representative for the latest revision of this document.

List of Tables

Table 1: Drive Carrier Interface Components ................................................................... 9Table 2: Communications Parameters ............................................................................. 15Table 3: Selecting Menu Options ..................................................................................... 38Table 4: LCD Display Components ................................................................................... 51Table 5: Main Menu Options ............................................................................................. 54Table 6: RAID Level Comparisons ................................................................................... 66Table 7: SCSI Set-Up ........................................................................................................ 68

Table C-1: Error Messages ................................................................................................ 110

Page 14: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

Introduction 1

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

INTRODUCTION

Packaging Information

The StorCase Technology InfoStation external expansion chassis is shipped in a containerdesigned to provide protection and prevent damage during shipment, as confirmed by theInternational Safe Transit Association (ISTA Procedure 1A). The InfoStation was carefullyinspected before and during the packing procedure at the factory. Evidence of any damageto the InfoStation should be reported to the shipper immediately.

If the wrong InfoStation model has been received, please call your reseller or StorCase at(800) 435-0642 to arrange for a Return Material Authorization (RMA). StorCase cannot ac-cept returns which do not display an RMA number on the outside of the package. Return theunit with all the original packing materials.

Before removing any component from its packaging, discharge any static electricity bytouching a properly grounded metal object.

Serial Number

The InfoStation is labeled with a serial number. This number must be reported to the StorCaseCustomer Service Representative in order to receive a Return Material Authorization (RMA)for warranty claims. Locate the serial number label and record the number in the spaceprovided below.

InfoStation Serial Number:

Page 15: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

2 Introduction

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

General Description

CAUTION: The InfoStation chassis contains NO USER SERVICEABLE parts inside the unit.Refer ALL servicing to qualified personnel!

NOTES: The configuration and use of the InfoStation RAID Controller requires a certainlevel of expertise and experience on the part of the user/integrator. Since thereare many configuration options and variables (ie. host platforms, applications,etc.), only general guidelines will be discussed in this User's Guide.

Refer to the disk manufacturer's documentation for specific information re-garding the disks.

High performance InfoStation 12-bay SCSI-to-Serial ATA and FC-to-Serial ATA RAID enclo-sures are designed to support low-profile Serial ATA (SATA) or Parallel ATA (Ultra ATA/100)drives for RAID applications. The SCSI-to-SATA enclosures (P/Ns S10H108 & S10H112)support dual SCSI Ultra320 host channels and are downward-compatible with earlier SCSIWide Single-Ended or LVD interface technologies (i.e. Ultra2 or Ultra). Daisy-chaining chassisfor extended storage is also possible with optionally available SCSI Ultra320 repeater kits. TheFC-to-SATA enclosures (P/Ns S10K102 & S10K104) support dual Fibre Channel ArbitratedLoops (FC-ALs) with 2Gbps operation.

Each standard 4U rack mount 12-bay RAID InfoStation chassis comes equipped with a RAIDcontroller, (12) removable drive carriers and an open 5.25" half-height device bay. Theseenclosures are constructed of corrosion-resistant steel and each include (2) hot-swappable,redundant 460W power supply modules and (2) hot-swappable, redundant, variable-speedfan modules.

Both the SCSI-to-SATA and FC-to-SATA RAID chassis support RAID levels 0, 1, 0+1, 3, 5, 30,and 50, and is OS independent. Online Capacity Expansion (OCE) and LUN support, up to1GB DDR PC2100 SODIMM cache memory, as well as automatic hot swap, hot spare anddrive rebuild support are all included. An audible alarm on the InfoStation alerts the User tosystem hardware failures and warning conditions. LED indicators at each drive bay provideadditional User feedback for drive activity, drive readiness and drive faults.

The InfoStation also incorporates "Soft Start" circuitry which eliminates in-rush current to eachof the installed drives during spin-up, as well as avoid power arcing during drive insertion.

A User Interface Module on the 12-bay InfoStation provides the User with a visual indicationof chassis configurations and communication statuses, in addition to providing an RS232connection for system environmental monitoring, configuration and control. InfoMon®, adownloadable chassis monitoring utility program, provides the InfoStation with a customizable,web-based monitoring capability via the RS-232 serial connection. InfoMon includes a “CallHome” feature, which enables chassis log information to be conveniently sent to a predeter-mined FTP site for trouble shooting and analysis. InfoMon also provides the User the ability toeasily configure both device and chassis settings with a few clicks of the mouse! Refer toAppendix B for further information on InfoMon.

Page 16: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

Introduction 3

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

The latest versions of the InfoMon utility program and User's Guide can be downloaded (freeof charge) from the StorCase web site (http://www.storcase.com). Contact StorCase forfurther information. Refer to Appendix B for further information on optional InfoStationaccessories.

Using a modular approach supported by redundant features and hot swapping capabilities,the InfoStation will provide continued data availability and allow for ease of maintenance andminimal system down time.

The modular and scalable design of the InfoStation chassis also allows a variety of futureproduct upgrades to be offered. Upgrade modules are anticipated InfoStation options.

This User's Guide describes the steps required for installing drive(s) into the InfoStationexternal expansion chassis. This guide is intended to supplement documentation provided withthe host computer system, the operating system, and the drive(s) to be installed within theInfoStation.

Features:

• 4U Rack Mount Chassis• One (1) 5.25" half-height bay (for canister-type SCSI device)• Supports dual SCSI Ultra320 host channels (SCSI-to-SATA version only)• Supports dual FC-ALs (FC-to-SATA version only)• Supports either twelve (12) Serial ATA or Ultra ATA/100 drives• Supports RAID levels 0, 1, 0+1, 3, 5, 30, 50• Supports 8 arrays and 128 LUNs• Corrosion-resistant steel construction• Two (2) 460W hot-swappable power supply modules• Two (2) hot-swappable variable-speed fan modules• Audible alarm• Status indicators at each bay• "Soft Start" circuitry• Web-based monitoring utility (InfoMon)• Data Master® Storage Manager GUI• Online Capacity Expansion (OCE)• Hot spare and automatic drive rebuild• Fax/Pager notification• OS independent (no software or special drivers required)• RS-232 connector for system environmental monitoring, configuration, and control• 128MB PC2100 DDR SODIMM memory• 7-year limited warranty* and free 24/7 technical support

* 3-year limited warranty on RAID controller and Power & Cooling Modules

Page 17: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

4 Introduction

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Figure 1: InfoStation 12-Bay RAID Chassis

Page 18: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

Introduction 5

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Front Panel(Figure 2)

• 5.25" Bay - One bay can accommodate one (1) half-height SCSI device.

• RAID Control Panel - Refer to Figure 8.

• Drive Carrier(s) - Accommodate up to twelve (12) 3.5" low-profile Parallel ATA orSerial ATA devices. Backplane design eliminates cable connections to drives,increases data integrity, and supports drive hot swappability.

• Drive Carrier LED(s) - Provides the following information:

Drive Ready (Blue) - Indicates that the drive is properly installed and readyfor access.

Drive Fault (Red) - Indicates a drive failure.

Drive Activity (Amber) - Indicates that the drive is being accessed.

Refer to Figure 5 & Table 1 for further information.

• Key Lock(s) - Assure proper seating of the drive carrier within the chassis andprevent unauthorized removal or installation of the carrier.

NOTE: The key lock is only to prevent unauthorized removal or installation of thedrive carrier. Locking the key lock is not requried for drive carrier oper-ation.

• Chassis Handle(s) - Provide a sturdy grip for the installation and removal of therack-mount chassis.

������������

��������

��� ���� ����

� �����

�����������

��� ���� ����

Figure 2: InfoStation Front Panel

Page 19: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

6 Introduction

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Rear Panel(Figure 3)

NOTE: Blank plate (provided) must be installed if any module slot is left empty. Instal-lation of the blank plate is necessary for proper cooling inside chassis.

• UI Module - LED panel displays system statuses, alarms, and warnings. Refer tosection "User Interface Module" for further information.

• I/O Panel - Provides two (2) DB9 connectors for RS-232 and Modem, and two (2)HD68 I/Os for SCSI Host channels (SCSI-to-SATA version only) or two (2) FC portsfor dual FC-ALs (FC-to-SATA version only). Also provides space for up to four (4)extra I/Os if desired.

• Power Supply Module(s) - Two (2) 460W redundant, hot swappable powersupply modules. Each module features overvoltage and overcurrent protection, totalusage hours, and power supply fault detection.

Module LED(s) -

Green LED - Steady glow indicates normal power supply operation.No glow indicates no A/C power.

Red LED - Steady glow indicates either:

Power supply failure.or

A/C cord is plugged in, but power switch is in the OFF position.

WARNING: DO NOT USE MODULE HANDLES TO LIFT CHASSIS! Thesehandles are specifically designed for the installation and re-moval of modules only!

Power Switch(es) - Rocker switch(es) control power to the power supplymodule(s).

A/C Power In - Accepts U.S. and other available international standard powercables.

• Fan Module(s) - Two (2) redundant, hot swappable fan modules. Each modulecontains two (2) high-pressure, variable-speed fans for ample chassis cooling (160CFM per module).

• Module Option - Allows the installation of StorCase upgrade products such as anoptional SNMP upgrade module. Contact StorCase for further information.

Page 20: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

Introduction 7

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Figure 3A: SCSI-to-SATA InfoStation Rear Panel

� !���

"��#��$

��% �&$''�#��$

(�#��$

� ���% ���

��% &%����

#��$ !'����

��)���� ����

&�&����� ����

Figure 3B: FC-to-SATA InfoStation Rear Panel

� !���

"��#��$

��% �&$''�#��$

(�#��$

� ���% ���

��% &%����

#��$ !'����

��)���� ����

"�����

Page 21: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

8 User Interface

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

LED Indicator and User Interface Panel

Each InfoStation provides the user with a visual indication of chassis environmental andconfiguration statuses, in addition to providing an RS-232 connection for system environmentalmonitoring, configuration, and control (Figure 4).

Figure 4: UI Module

LED Indicator/UI Panel Components

RS-232 - RS-232 serial connection used for InfoStation external monitoring andSerial Port configuration

Reset Switch - Resets InfoStation User Interface Module (will not reset SCSI bus)

Override - ON = Warning condition commands are overridden(Amber)

NOTE: Factory default is OFF (recommended).

Mute - ON = Audible alarm is disabled(Amber)

Fault - ON = One or more fault conditions(Red)

Warning - ON = One or more warning conditions(Amber)

Power - ON = Power to the chassis is ON(Green)

�&*�+�& ������� � �

#$�

,����-

��%

"�$�

!� ��

Page 22: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

User Interface 9

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

The Drive Carrier Interface consists of the following indicators:

Table 1: Drive Carrier Interface Components

Figure 5: InfoStation Drive Carrier Interface

Drive Carrier Interface Panel

Each InfoStation drive carrier provides a User interface for individual carrier operation.

��� �� ��� ��� �"�$����� ��(��-�%�������� ���������� ������� � �

���� ����.����� ���

����-�%�������� ����� �.��$ �

�#����-�%�������� ����� ����/ ��-��� �� ��

��� �������������

& ����0���-��������� ����� ���� ���.��& ����0����� ��

1!��-��������� ����� ���� ����.���� ��0����� ��

��� �� ���2����� �"�$�3

��� ��������

& ����0���-�

� �����

��� ����

����

Page 23: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

10 User Interface

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Inserting a Drive Carrier (with Drive Installed)

NOTES: A new drive can be inserted into an empty bay at anytime. However, the drivewill not be ready for access until the following procedure is followed.

The key lock is only to prevent unauthorized removal or installation of the drivecarrier. Locking the key lock is not required for drive carrier operation.

1. Simply insert the drive carrier into the empty bay.

2. Drive is ready to be accessed when the Drive Ready LED glows BLUE.

Removing a Drive Carrier (with Drive Installed)

CAUTION: Proper procedure must be followed when removing a disk drive from the drivebay. It is the responsibility of the operator to ensure that the host does notaccess the drive while attempting to remove the disk drive, and to follow theprocedure outlined below. Failure to do so may result in loss of data and/ordamage to the drive itself!

NOTE: Refer to the InfoStation Installation Guide for detailed information on inserting/removing drives from the InfoStation chassis.

1. Verify that the Drive Activity LED is OFF before removing drive.

2. Unlock the key lock (if locked) and remove the drive carrier by pulling on carrier handle.

Configuring Device and Chassis Settings

NOTE: Refer to the InfoMon User's Guide for further information.

If necessary, use InfoMon to change any factory default device or chassis settings. Pleaserefer to the InfoMon User's Guide for further information.

Page 24: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

SCSI Channel and FC Configurations 11

TYPICAL SCSI CHANNEL CONFIGURATION(For SCSI-to-SATA version only)

CAUTION: VHDCI connectors are easily damaged by improper handling. Visually inspecteach connector for bent contacts and carefully align prior to insertion.

NOTES: The configuration and use of the InfoStation RAID Controller requires a certainlevel of expertise and experience on the part of the user/integrator. Since thereare many configuration options and variables (ie. host platforms, applications,etc.), only general guidelines will be discussed in this User's Guide.

For daisy-chaining applications, total device-to-host cable length should notexceed 12m (approx. 39ft) per SCSI specifications.

Figure 6: Typical Dual SCSI Host Connection to InfoStation

40*566 �1&�0 7���

�8� ��#�� 7

0��&�&������6

0��&�&������5

Page 25: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

12 SCSI Channel and FC Configurations

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

TYPICAL FIBRE CHANNEL CONFIGURATION(For FC-to-SATA version only)

CAUTION: DO NOT bend the LC (optical) cable beyond the cable's minimum bend radius,data transmission degradation may occur. Follow cable manufacturer'sguidelines for bend radius limitation.

WARNING: DO NOT look directly into the open end of an active LC (optical) cable or opticalSFP module (with plugs removed)! Serious eye damage can occur from directexposure to the infrared light!

NOTES: The configuration and use of the InfoStation RAID Controller requires a certainlevel of expertise and experience on the part of the user/integrator. Since thereare many configuration options and variables (ie. host platforms, applications,etc.), only general guidelines will be discussed in this User's Guide.

LC (optical) SFP Modules support both 2Gbps and 1Gbps operation.

Figure 7: FC Ports and LEDs

���'�����'��

&0

��0

&0

��0

&���$�����

������������

"������

LEDs

Status - ON = Steady glow during power up indicates RAID controller initialization(will turn OFF once initialization is complete and if SFP is not connec-ted to Host). LED will remain ON if SFP is connected to Host.

Activity - ON = Steady glow indicates activity(Blue)

Page 26: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

SCSI Channel and FC Configurations 13

40*566 �1&�0 7���

�8� ��#�� 7

0��"������6

0��"������5

"�*���95"�*���9�

Figure 8: Typical Dual FC Loops Connection to InfoStation

Page 27: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

14 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

RAID CONTROLLER CONFIGURATION

NOTES: The configuration and use of the InfoStation RAID Controller requires a certainlevel of expertise and experience on the part of the user/integrator. Since thereare many configuration options and variables (i.e.. host platforms, applications,etc.), only general guidelines will be discussed in this User's Guide.

Also refer to the disk manufacturer's documentation for specific informationregarding the disks.

RAID Management Connection

NOTES: Microsoft® Windows® 3.x and Windows® NT™ 3.5x include a program calledTerminal which does not support ANSI color. If using either O/S, select VT-100for terminal emulation or use a third-party software program such as Procommfor Windows.

Microsoft® Windows® 95/98/NT/2000 includes a program called HyperTerminalthat supports ANSI color.

Macintosh O/S includes a program called ZTerm for terminal emulation.

The Data Master Storage Manager GUI is included on the StorCase ResourceKit CD (provided with each InfoStation). The latest version can also be down-loaded from the StorCase web site at: http://www.storcase.com/support/datamaster.asp

Refer to the Data Master User's Guide for further information.

Both the Monitor Utility (HyperTerminal) and Data Master GUI are implemented with a VT-100or ANSI terminal connected through the DB9 port on the rear of the InfoStation chassis (Fi-gure 9).

Page 28: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 15

Figure 9: DB9 Port Location(SCSI-to-SATA version shown)

��

)�

���

���

����� �����

40*566 �1&�0 7���������#���

���� ������8� ��#�� 7

Table 2: Communications Parameters

Set the communications parameters (Table 2):

NOTE: The same parameters apply to both HyperTerminal and Data Master GUI.

������� ����

��$�����

���������

&��'�����

�����

"�%������

�:66;�:<66;�)=66;�5::66;�5)�66;�<<66;�+<:66;��>=66;�55��66

>;�<

5;��

1�� ;�!��;��� �

?�� ?�..;����%� ;�1��

�� ������

55��66

<

5

1��

1��

Page 29: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

16 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Configuring the RAID Controller

There are two aspects to configuring the RAID controller:

• Configuration of the RAID system and communication parameters• Setting up and configuration of arrays within the RAID system

Users are advised to configure the system first, then the arrays.

The following sections provide instructions on how to setup a RAID configuration for the firsttime.

Choose one of the three following methods:

RAID Configuration via Data Master GUI Page

• Data Master Connection (Read FIRST before proceeding to RAID Setup) 17• Quick RAID Setup (One array using all disks installed) 22• Customized RAID Setup (Multiple arrays & custom number of disks in an array) 24• Partitions 26• LUN Mapping 32• Deleting an Array 35

RAID Configuration via Monitor Utility (HyperTerminal) Page

• HyperTerminal Connection (Read FIRST before proceeding to RAID Setup) 36• Quick RAID Setup (One array using all disks installed) 39• Customized RAID Setup (Multiple arrays & custom number of disks in an array) 40• Partitions 42• LUN Mapping 46• Deleting an Array 49

RAID Configuration via InfoStation RAID Control Panel Page

• RAID Control Panel (Read FIRST before proceeding to RAID Setup) 50• Quick RAID Setup (One array using all disks installed) 55• Customized RAID Setup (Multiple arrays & custom number of disks in an array) 56• Partitions 58• LUN Mapping 60• Deleting an Array 61

Page 30: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 17

RAID Configuration via Data Master GUI

NOTES: The Data Master Storage Manager GUI is included on the StorCase ResourceKit CD (provided with each InfoStation).

The latest version can also be downloaded from the StorCase web site at:http://www.storcase.com/support/datamaster.asp

Refer to the Data Master User's Guide for further information.

Data Master Storage Manager GUI may be used to configure the InfoStation RAID controller.Data Master makes it very easy to manage and monitor the StorCase InfoStation RAID sys-tem. The system can be managed and monitored from a remote location using the Internetor Intranet. Also, multiple systems can be managed and monitored from a single screen (withthe Multiple Version).

Data Master Connection

1. Install and insert all drives to be used in the array, and power up the InfoStation byturning on both power supply modules simultaneously.

2. Connect the COM1 port to the InfoStation RS-232 port using the provided serial ca-ble.

3. Install Data Master onto the workstation connected to the InfoStation(www.storcase.com/support/datamaster.asp).

4. If you are opening Data Master for the first time, you will be prompted to enter thename of your connection (Figure 10A). Enter the desired name in the "ConnectionName" field.

Confirm that all settings are correct and click Continue.

Figure 10A: Connection Name Setup Screen

Page 31: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

18 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Figure 10B: Connection Screen(If there is already a connection to an InfoStation)

If this not the first time opening Data Master and there is already a connection to anInfoStation, the following screen should appear (Figure 10B).

Confirm that all settings are correct and click Update.

If successful, Data Master will open with InfoStation connection present. SkipSteps 5-10 and proceed to sections "Quick Setup" or "Customized Setup" onpages 23-29 of this User's Guide.

5. Select the location of the InfoStation RAID system (Figure 10C).

Check “Local” connection if RAID system is connected via RS-232.

Check “Remote” connection if RAID system is connected via TCP/IP (refer to theData Master User’s Guide for further information).

Confirm that all settings are correct and click Continue.

Page 32: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 19

Figure 10C: Location Type Setup Screen

Figure 10D: Serial Port Setup Screen

6. Select the connection type from the "Serial Port" dropdown menu (Figure 10D).

If using a “Local” connection (via RS-232), Serial Port should be set to COM1.

For “Remote” connection (via TCP/IP), refer to the Data Master User’s Guide forfurther information.

Confirm that all settings are correct and click Continue.

Page 33: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

20 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Figure 10E: Baud Rate Setup Screen

8. To set access rights, check the Set Access box (Figure 10F).

Confirm that all settings are correct and click Continue.

7. Select the Baud Rate from the "Baud Rate" dropdown menu (Figure 10E).

If using a “Local” connection (via RS-232), Baud Rate should be set to 115200.

For “Remote” connection (via TCP/IP), refer to the Data Master User’s Guide forfurther information.

Confirm that all settings are correct and click Continue.

Figure 10F: Set Access Screen

Page 34: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 21

9. Enter password (default password = 00000000) in the "Password" field (Figure10G).

Confirm that all settings are correct and click Continue.

Figure 10G: Password Screen

Figure 10H: Confirmation Screen

10. Confirm that all settings are correct and click Update (Figure 10H).

If successful, Data Master will open with InfoStation connection present.

If a change is necessary, click Start Over instead.

Page 35: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

22 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

3. Select the desired RAID level.

4. Select the desired stripe size (default = 128MB).

5. Select the desired number of partitions.

NOTES: When using the Quick Setup option, the array will be created onALL disks within the InfoStation (any disks intended for use asspares should be physically removed prior to creating the array).

OS limitation is 2.0 TB maximum. However, multiple arrays or parti-tions can be created to achieve over 2.0 TB capacity (e.g. onearray/partition with 2.0 TB, the other array/partition with 1.0 TB, ora combination thereof).

QUICK RAID SETUP(One array using all disks installed)

1. Remove any disks unintended for the array (any disks intended for use as sparesshould be physically removed prior to creating the array).

2. To create an array, select the Quick Setup option from the Array dropdownmenu (Figure 11).

Figure 11: Data Master Quick Setup Option

Page 36: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 23

6. After the array is created, insert any disks for use as spares.

7. Once setup is complete:

• If multiple partitions are required, proceed to section "Partitions" on page 26 ofthis User's Guide.

• If no additional partitions are required, proceed to section "LUN Mapping" onpage 32 of this User's Guide.

Confirm that all settings are correct and click the Update button located on theRAID Creation screen (Figure 12).

Any disks not included in the array will automatically be added as spares.

Figure 12: Data Master RAID Creation Screen

Page 37: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

24 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

CUSTOMIZED RAID SETUP(Multiple arrays and custom number of disks in an array)

NOTE: Please familiarize yourself with section "Data Master Connection" on page17 before proceeding with customized RAID setup.

1. To create an array, select the Create option from the Array dropdown menu(Figure 13).

The following screen (Figure 14) will appear.

Figure 13: Data Master Create Array Option

Page 38: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 25

Figure 14: Data Master Create Array Screen(Example shown, actual screen may vary)

2. Select the desired Array number in the "Select Array" section.

3. Select the desired RAID level in the "Select RAID Level" section.

4. Select the desired stripe size in the "Stripe Size" field.

5. Select either Random or Sequential in the "Select Performance" section.

6. If any partition in any of the arrays is over 2TB capacity:

a. Select Enable in the "Larger Than 2TB" section.

b. Select the desired sector size in the "Sector Size" section. Partition sector sizedepends on the OS.

7. Select the quantity of disks for creating the Array in the "Number of Disk Drives" field.Selected disks will display in both the "List" and "Physical View" sections.

Page 39: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

26 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Partitions

NOTE: Please familiarize yourself with the following information before proceedingto section "Setting Up Multiple Partitions" on page 27.

Partitions Greater than 2TB

If creating a RAID array larger than 2TB in total capacity, two (2) partitions will automaticallybe created (Figures 18A & 18B).

• Partition 1 will be approximately 2TB.

• Partition 2 will be the remaining capacity beyond 2TB (unless otherwise specified).

• If equal partitions are desired, change Partition 2 to capacity = 0GB. Once Partition 2capacity is changed, change Partition 1 to desired capacity.

You are now ready to proceed to section "Setting Up Multiple Partitions" on the next page.

8. Select the desired quantity of partitions in the "Number of Partitions" field. Availablepartitions depend on the InfoStation model.

The size of each partition is shown in the "Size (GB)" field (size of all partitions areequal). If another size is desired, enter the desired GB value in the "Size (GB)" field.

9. Select a LUN for the Primary Host Channel in the "Primary Host Channel LUN" drop-down field.

10. Select a LUN for the Secondary Host Channel in the "Secondary Host Channel LUN"dropdown field.

11. Confirm that all settings are correct and click Create to save changes.

12. Once setup is complete:

• If multiple partitions are required, proceed to section "Setting Up Multiple Part-itions" on page 27 of this User's Guide.

• If no additional partitions are required, proceed to section "LUN Mapping" onpage 32 of this User's Guide.

Page 40: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 27

SETTING UP MULTIPLE PARTITIONS

1. To create an array, select the Partitions option from the Array dropdown menu(Figure 15).

2. Unlock default partitions by un-checking boxes located to the left of the partition list(highlighted in Figure 16).

3. Choose desired number of partitions in the Number of Partitions drop down menuat the top of the partition configuration page (Figure 15).

All partitions will be divided into equal capacities.

Figure 15: Data Master Partitions Option

Page 41: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

28 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Figure 16: Data Master Create Partitions Screen

4. If unequal capacities are desired, enter the desired partition sizes into the Recon-figure Size (GB) field for each partition (highlighted in Figure 17).

Page 42: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 29

Figure 17: Data Master Reconfigure Partitions Option

5. Confirm that all settings are correct and click Reconfigure Partitions (Figure 17).

6. Once partitions are created, proceed to section "LUN Mapping" on page 32 of thisUser's Guide.

Page 43: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

30 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Example:

RAID 0 being created with approximately 2.2TB total capacity.

Figure 18A: Example of a RAID 0 Creation with 2.2TB Total Capacity

Page 44: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 31

You will notice that by default, two partitions were created (Figure 18B).

P1 = 2048GBP2 = 182GB

Figure 18B: Example of a RAID 0 Creation with 2.2TB Total Capacity

Page 45: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

32 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

LUN Mapping

1. After the array and Partitions have been created, each partition needs to be as-signed a LUN and mapped to the appropriate SCSI Channel.

2. Select the LUN Mapping option from the Array dropdown menu (Figure 19).

3. Starting With LUN 0, assign one LUN to each partition of each array.

Select the array(s) and partition(s) in the Select Array and Select Partitionfields in the LUN Mapping screen (Figures 20A or 20B).

4. Confirm that all settings are correct and click Update (Figures 20A & 20B).

Figure 19: Data Master LUN Mapping Option

Page 46: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 33

Example:

One Array and one Partition mapped to the Primary SCSI channel only.

Figure 20A: Example of One Array and One PartitionMapped to Primary SCSI Channel

Page 47: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

34 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Example:

Two Arrays and two Partitions, each mapped to both Primary and Secondary SCSI chan-nels.

Figure 20B: Example of Two Arrays and Two PartitionsMapped to both Primary and Secondary SCSI Channels

Page 48: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 35

Deleting an Array

1. Select the Delete option from the Array dropdown menu (Figure 19).

2. Select the desired array to be deleted.

3. Click Delete located at the bottom of the screen.

Page 49: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

36 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

RAID Configuration via HyperTerminal

NOTES: Microsoft® Windows® 3.x and Windows® NT™ 3.5x include a program calledTerminal which does not support ANSI color. If using either O/S, select VT-100for terminal emulation or use a third-party software program such as Procommfor Windows.

Microsoft® Windows® 95/98/NT/2000 includes a program called HyperTerminalthat supports ANSI color.

Macintosh O/S includes a program called ZTerm for terminal emulation.

The Monitor Utility (HyperTerminal) may be used to configure the InfoStation RAID controller.

HyperTerminal Connection

To find HyperTerminal in Windows:

1. Click on Start (normally located at the bottom left of the Windows desktop)

2. Go to Programs

3. Go to Accessories

4. Go to HyperTerminal

Settings(Figure 21A)

· Select the appropriate COM port that the StorCase serial cable is connected to on the host(default = COM1).

· Set Bits Per Second to 115200.· Set Data Bits to 8.· Set Parity to None.· Set Stop Bits to 1.· Set Flow Control to None.

Page 50: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 37

Figure 21B: Monitor Utility (HyperTerminal) Screen(Actual screen may vary)

Figure 21A: HyperTerminal Connection Screen

When blank connection page displays, press <CTRL D> twice.

HyperTerminal should now be connected to the InfoStation RAID system (Figure 21B).

Page 51: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

38 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Table 3: Selecting Menu Options

# �$�!'����� � ��

&@���6�

�8��

#�� �('

#�� ���%�

& ��

&%������� �#�1(��!(0�(0��� �

���

���

0�/

���

��A

Selecting Menu Options

Use the following information (Table 3) to navigate through the Monitor Utility (HyperTerminal)menu options:

Page 52: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 39

QUICK RAID SETUP

1. Invoke the HyperTerminal screen.

2. <TAB> to the Menu side of the screen and press <ENTER>. Enter password(default password = 00000000).

3. Remove any disks unintended for the array (any disks intended for use as sparesshould be physically removed prior to creating the array).

4. Select the Quick Setup option to create an array. Press <ENTER>.

You will be prompted to select the RAID level to create.

5. Select desired RAID level and press <ENTER>.

Select Yes and press <ENTER>.

NOTES: When using the Quick Setup option, the array will be created onALL disks within the InfoStation (any disks unintended for the arrayshould be physically removed prior to creating the array).

OS limitation is 2.0 TB maximum. However, multiple arrays or parti-tions can be created to achieve over 2.0 TB capacity (e.g. onearray/partitions with 2.0 TB, the other array/partitions with 1.0 TB,or a combination thereof).

6. After the array is created, insert remaining disks for use as spares (spares areadded automatically).

7. Once setup is complete:

• If multiple partitions are required, proceed to section "Partitions" on page 42 ofthis User's Guide.

• If no additional partitions are required, proceed to section "LUN Mapping" onpage 46 of this User's Guide.

Page 53: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

40 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

CUSTOMIZED RAID SETUP

NOTE: Please familiarize yourself with section "HyperTerminal Connection" on page 36 before proceeding with customized RAID setup.

1. Invoke the HyperTerminal screen.

2. <TAB> to the Menu side of the screen and press <ENTER>. Enter password(default password = 00000000).

3. RAID configuration:

a. Use �� keys to select RAID PARAMS. Press <ENTER>.

b. Select Array 1 and press <ENTER>.

c. Select Reconfig-RAID and press <ENTER>.

Select Yes and press <ENTER>.

d. Arrow down and select RAID Level. Press <ENTER>.

Select x (x = desired RAID level) and press <ENTER>.

e. Arrow down and select Disk Number. Press <ENTER>.

Select the number of disks to be used in the array and press <ENTER>.

NOTES: Any disks not selected for the array will automatically be addedas spares.

OS limitation is 2.0 TB maximum. However, multiple arrays orpartitions can be created to achieve over 2.0 TB capacity (e.g.one array/partition with 2.0 TB, the other array/partition with1.0 TB, or a combination thereof).

f . Press <ESC> twice.

Page 54: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 41

g. Arrow down and select NVRAM. Press <ENTER>.

Select Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

Arrow down and select Restart. Press <ENTER>.

Select Yes and press <ENTER>.

4. Controller will now reboot and the RAID x array will start initialization.

NOTE: Initialization may take several hours, depending on the overall capa-city of the array being configured.

5. For additional arrays, repeat Steps 1-3.

6. Once setup is complete:

• If multiple partitions are required, proceed to section "Partitions" on page 42 ofthis User's Guide.

• If no additional partitions are required, proceed to section "LUN Mapping" onpage 46 of this User's Guide.

Page 55: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

42 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Partitions

NOTE: Please familiarize yourself with the following information before proceedingto section "Setting Up Multiple Partitions" on page 43.

Partitions Greater than 2TB

If creating a RAID array larger than 2TB in total capacity, two (2) partitions will be created.

1. Partition 1 will be approximately 2TB.

2. Partition 2 will be the remaining capacity beyond 2TB (unless otherwise specified).

3. If equal partitions are desired, change Slice 01 to capacity = 0GB. Once Slice 01capacity is changed, change Slice 00 to desired capacity.

You are now ready to proceed to section "Viewing Default Partition Configuration".

VIEWING DEFAULT PARTITION CONFIGURATION

1. <TAB> to the Menu (left) side of the screen and press <ENTER>.

2. Enter password (default password = 00000000).

3. Select RAID Funcs. Press <ENTER>.

4. Select Statistics. Press <ENTER>.

5. <TAB> to the Output (right) side of the screen and press <ENTER>.

6. Scroll up to the "RAID Statistics" section to view Partition values.

Page 56: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 43

SETTING UP MULTIPLE PARTITIONS

1. <TAB> to the Menu (left) side of the screen and press <ENTER>.

2. Enter password (default password = 00000000).

3. Partition configuration:

a. Use �� keys to select RAID PARAMS. Press <ENTER>.

b. Select Array x (x=desired array) and press <ENTER>.

c. Select Reconfig-RAID and press <ENTER>.

Select Yes and press <ENTER>.

d. Arrow down and select Slice. Press <ENTER>.

NOTE: If creating a RAID array larger than 2TB in total capacity, two (2)partitions will be created. If equal partitions are desired, changeSlice 01 to capacity = 0GB. Once Slice 01 capacity is changed,change Slice 00 to desired capacity. Proceed to "Step e".

e. Select Slice 0 and press <ENTER>.

Enter desired slice (partition) capacity and press <ENTER>.

If new partition/slice is smaller than default partition/slice, clear any remainingnumbers by pressing <SPACEBAR>.

NOTE: Remaining capacity will be added to Slice 1 as a second partition.Confirm the partition size by reentering the number displayed inSlice 1 and press <ENTER>.

f . If three (3) or more partitions are desired, repeat Step e for last created slice.

NOTE: Changing last slice to desired capacity will result in remainingcapacity being added to an additional slice.

g. Press <ESC> three times.

Page 57: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

44 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

h. Arrow down and select NVRAM. Press <ENTER>.

Select Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

Arrow down and select Restart. Press <ENTER>.

Select Yes and press <ENTER>.

Verify the newly saved slice settings by viewing default slice configuration (refer to section"Viewing Default Partition Configuration" on page 42 of this User's Guide for furtherinformation) .

Page 58: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 45

You will notice that by default, two partitions were created (Figure 22).

P1 = 2097GB (located in Output, or right side of the screen)P2 = 186GB

Figure 22: Example of a RAID 0 Creation with 2.2TB Total Capacity

Example:

RAID 0 being created with approximately 2.2TB total capacity.

Page 59: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

46 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

LUN Mapping

1. After the array and partitions have been created, each partition needs to be as-signed a LUN and mapped to the appropriate SCSI Channel.

2. <TAB> to the Menu (left) side of the screen and press <ENTER>.

3. Enter password (default password = 00000000).

4. Select SCSI Params and press <ENTER>.

a. Select the SCSI channel your host server is connected to (Primary or Sec-ondary SCSI) and press <ENTER>.

b. Select LUN MAP and press <ENTER>.

c. Starting with LUN 0, assign one LUN number to each partition (slice).

Select LUN number and press <ENTER>.

d. After selecting LUN number, select the array the partition is in and press<ENTER>.

e. Select the partition (slice) you would like to assign this LUN number to andpress <ENTER> (Figure 23).

Slices always start with “00” and increase sequentially according to thenumber of partitions that have been created.

Page 60: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 47

5. Press <ESC> four times to return to the Main Menu.

6. Arrow down and select NVRAM. Press <ENTER>.

7. Select Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

8. Select Restart and press <ENTER>.

Select Yes and press <ENTER>.

9. Controller will now reboot (LUN will be mapped upon reboot).

10. To verify LUN Mapping settings, select RAID FUNCS from the Main Menu and press<ENTER>.

11. Select Statistics and press <ENTER>.

12. <TAB> to highlight the Output (right) side of the HyperTerminal screen. Use the�� keys to scroll through Output to view either the “Primary SCSI Channel” or“Secondary SCSI Channel” (depending where the LUNs were mapped to).

13. If the LUN settings were successfully applied, you should see the array numberand slice numbers listed in the LUN Map section (Figure 24).

Figure 23: HyperTerminal LUN Map Option

Page 61: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

48 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Example:

One Array and two Slices mapped to Primary SCSI channel.

You will notice there are two sets of numbers in the LUN Map section (highlighted in Figure24).

a. First number ( 10 11 xxxxx...) represents the Array #

b. Second number ( 10 11 xxxxx...) represents the LUN #

Figure 24: Example of One Array and Two SlicesMapped to the Primary SCSI Channel

Page 62: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 49

Deleting an Array

1. Invoke the HyperTerminal screen.

2. <TAB> to the Menu side of the screen and press <ENTER>. Enter password(default password = 00000000).

3. Deleting an array:

a. Use �� keys to select RAID PARAMS. Press <ENTER>.

b. Select array to be deleted and press <ENTER>.

c. Select Reconfig-RAID and press <ENTER>.

Select Yes and press <ENTER>.

d. Arrow down and select RAID Level. Press <ENTER>.

Arrow down and select None. Press <ENTER>.

e. Press <ESC> twice.

f . Arrow down and select NVRAM. Press <ENTER>.

Select Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

Arrow down and select Restart. Press <ENTER>.

Select Yes and press <ENTER>.

Page 63: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

50 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

RAID Configuration via InfoStation RAID Control Panel

The InfoStation RAID Control Panel may be used to configure the InfoStation RAID controller.

RAID Control Panel

The RAID control panel (Figure 25) allows for exploration of all configuration options. However,the LCD screen can only display limited amounts of information at a time.

To display all information on a larger terminal screen, the RAID Controller can be accessed viaa computer serial port (female DB9-female DB9 cable provided) using either the Monitor Utility(HyperTerminal) or Data Master GUI.

NOTE: The Monitor Utility and the front control panel cannot be used at the same time.When one is active, the other is disabled.

Figure 25: LCD Display and Control Panel

�����������

&���(��$����

&����!,1�$����

��� �$����

����' �$����

��% ���

������'��

Page 64: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 51

When the Enter button is pressed in Operation Mode, the RAID Controller will go intoConfiguration Mode.

NOTE: Configuration Mode will automatically cancel after 3 minutes (180 seconds) ofUser inactivity.

Table 4: LCD Display Components

LEDs

Activity Indicates data is being accessedPower Indicates power is ON

Control Panel Buttons

� Use to scroll UP through the menu items� Use to scroll DOWN through the menu itemsENT Use to select a menu item, open a sub-menu, or to select a a valueESC Use to exit a sub-menu and return to the previous menu

���� �����������

�"&�8888 8�0��*��

!!!!!!!!!!!&

����� �����������

#�� ��$7/ B

���������$����0� �.��� ���!������ � .����������5�� �������/$���������� %��� �� 8��'�- �

?

!

&

����������������� ��

��������/ ��-���� ��

��������!��� �2&��- ����3�

�����������'� ������

�������� 7�� ��

��������/ ��-��� �� ��

�8

��C8

����� � �28�D�6;�6E5;�5;�+;��;�+6;����63����.�-$������

&�&��������.�-$������28D6*5�3�

�� �����-��$������������-��' �����������$��

5�

+

:

F

����5�!��� �2#$��' ����3�

������!��� �2#$��' ����3�

����+�!��� �2#$��' ����3�

����:�!��� �2#$��' ����3�

F�!��2F$������$�����.������3

B� �"&�(+�6 &�0�*��D���.�&�������(+�6*��*& ����0������� ����$ �"&�(+�6 ��0�*��D���.�&�������(+�6*��*��� ��0������� ����$ �"&�"� &�0�*��D���.�&�������"�*��*& ����0������� ����$ �"&�"� ��0�*��D���.�&�������"�*��*��� ��0������� ����$ �"&�(+�6 &�0�*F�D���.�&�������(+�6*��*& ����0��F�!�� ����$ �"&�(+�6 ��0�*F�D���.�&�������(+�6*��*��� ��0��F�!�� ����$ �"&�"� &�0�*F�D���.�&�������"�*��*& ����0��F�!�� ����$ �"&�"� ��0�*F�D���.�&�������"�*��*��� ��0��F�!�� ����$

Page 65: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

52 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Operation Mode

The front panel LCD continuously displays the current status of the RAID Controller. A typicaldisplay will look like the following:

�"&�8888 8�0��*�8!!!!!!!!!!!&

����� ��# 7�����������#��� �

����5���'��������������#��� �

�����

�����

�����

��(�0�' �<6+�5

& ���1$7/

"�7%� �� ������

�����

�����

�����

����5��8

�����

����<���'��������������#��� �

�����

�����5

�����5�

�����

����<��8

�����

Page 66: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 53

Mode Operation

The SCSI-to-SATA RAID Controller operates in three (3) modes:

• Self-Diagnostic Mode

• Configuration Mode

• Operation Mode

Self-Diagnostic Mode

To ensure flawless operation, the RAID Controller has a built-in self-diagnostic utility. Self-Diagnostic Mode occurs automatically upon power up, or after the RAID Controller has beenreset. During this mode, all components are tested and any potential problems are reported.

The Self-Diagnostic Mode runs three major diagnostic tests. The first diagnostic includestesting the CPU and supporting core logic chips, the internal bus, memory, SCSI controller,SATA controllers, and RS-232 controllers. The second diagnostic tests for the presence ofdisks on each individual disk channel. It also checks the functionality of each disk found. Thefinal diagnostic tests the RAID functionality.

Configuration Mode

NOTE: The RAID Controller should be OFFLINE (disconnected from the host system)when Configuration Mode is running.

Configuration Mode may be selected whenever <ENTER> is pressed during Operation Modeor when the Monitor Utility is invoked from the remote terminal. In Configuration Mode, the useris able to modify the settings of the RAID Controller and perform different functions to thecontroller.

Entering a Password

If the password-check feature is enabled, the user will be prompted to enter a passwordbefore proceeding (the default password is "00000000"). Refer to section "4 PasswordSecurity" for information on how to change the default password.

The user may use the front control panel buttons to enter the password. Use the � and �keys to scroll through the available characters, then press <ENTER> to select the characterand move to the next position. Once all the characters have been entered, press <ENTER>to access the Configuration Mode.

Page 67: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

54 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

The Main Menu consists of six (6) categories, as shown in Table 5.

Table 5: Main Menu Options

��������

5���������7�

��&�&�����7��2���������� ������ ���3

���"�/ ����7��2�������� ������ ���3

+��&�+�����7�

:�&��� 7����7�

��14��#

=������"$���

6�G$����& �$'

Main Menu Options Functions

Quick Setup Quick setup of single RAID array

RAID Params Set parameters for single or multiple arrays

SCSI Params Set SCSI parameters such as SCSI ID, speed, and LUN Mapping(For SCSI-to-SATA only)

Fibre Params Set fibre parameters such as hard loop ID, connection mode,(For FC-to-SATA only) data rate, LUN mapping and enabling/disabling SAN masking

RS232 Params Set parameters for modem connection and RS232 connectionto terminal

System Params Set/enable/disable password securityConfigure fax and pager alert settings

NVRAM Save new configurations and restart RAID controller

RAID Funcs Initialize and check RAID 3/5 arraysAdd/remove disks to existing arraysView system statisticsCancel error messagesAlarm settingsExpand arrayUpdate firmware

For detailed information regarding these Main Menu options and all their functions, refer tosection "RAID Controller Configuration Overview" on pages 62-84 of this User's Guide.

Page 68: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 55

#����# �$6�G$����& �$'

4. Use the �� keys to browse through the various RAID levels. Press <ENTER>to select the desired RAID level.

6�G$����& �$'� � �8

QUICK RAID SETUP

1. Install and insert all drives to be used in the array, and power up the InfoStation byturning on both power supply modules simultaneously. Any disks intended for useas spares should be physically removed prior to creating the array.

2. Use the InfoStation RAID Control Panel to create an array (Figure 25).

3. Press <ENTER> once to invoke the 0 Quick Setup option. Press <ENTER> againto select option.

5. Once the desired RAID level is selected, you will be prompted to confirm your se-lection. Select Yes to confirm.

NOTES: When using the Quick Setup option, the array will be created onALL disks within the InfoStation (any disks intended for use asspares should be physically removed prior to creating the array).

OS limitation is 2.0 TB maximum. However, multiple arrays or parti-tions can be created to achieve over 2.0 TB capacity (e.g. onearray/partitions with 2.0 TB, the other array/partitions with 1.0 TB,or a combination thereof).

� � �8H � 1�

6. After the array is created, insert any disks for use as spares.

7. Once setup is complete:

• If multiple partitions are required, proceed to section "Partitions" on page 58 ofthis User's Guide.

• If no additional partitions are required, proceed to section "LUN Mapping" onpage 60 of this User's Guide.

Page 69: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

56 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

CUSTOMIZED RAID SETUP

NOTES: Please familiarize yourself with section "RAID Control Panel" on page 50before proceeding with customized RAID setup.

Refer to sections "1 RAID Params" and "5 NVRAM" of this User's Guide forfurther information.

1. Press <ENTER> to invoke the Password screen.

2. Enter password (default password = 00000000).

3. RAID configuration:

a. Use �� keys to select 1 RAID PARAMS. Press <ENTER>.

b. Select 1.1 Array 1 and press <ENTER>.

c. Select 1.1.1 Reconfig-RAID and press <ENTER>.

Select Yes and press <ENTER>.

d. Arrow down and select 1.1.2 RAID Level. Press <ENTER>.

Select x (x = desired RAID level) and press <ENTER>.

e. Arrow down and select 1.1.3 Disk Number. Press <ENTER>.

Select the number of disks to be used in the array and press <ENTER>.

NOTES: Any disks not selected for the array will automatically be addedas spares.

OS limitation is 2.0 TB maximum. However, multiple arrays orpartitions can be created to achieve over 2.0 TB capacity (e.g.one array/partition with 2.0 TB, the other array/partition with1.0 TB, or a combination thereof).

f . Press <ESC> twice.

Page 70: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 57

g. Arrow down and select 5 NVRAM. Press <ENTER>.

Select 5.1 Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

Arrow down and select 5.3 Restart. Press <ENTER>.

Select Yes and press <ENTER>.

4. For additional arrays, repeat Step 3.

5. Once setup is complete:

• If multiple partitions are required, proceed to section "Partitions" on page 58 ofthis User's Guide.

• If no additional partitions are required, proceed to section "LUN Mapping" onpage 60 of this User's Guide.

Page 71: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

58 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Partitions

Partitions Greater than 2TB

If creating a RAID array larger than 2TB in total capacity, two (2) partitions will be created.

1. Partition 1 will be approximately 2TB.

2. Partition 2 will be the remaining capacity beyond 2TB (unless otherwise specified).

3. If equal partitions are desired, set Partition 2 to capacity = 0GB. Once Partition 2capacity is changed, change Partition 1 to desired capacity.

SETTING UP MULTIPLE PARTITIONS

NOTE: Refer to sections "1 RAID Params" and "5 NVRAM" of this User's Guide for furtherinformation.

1. Press <ENTER> to invoke the Password screen.

2. Enter password (default password = 00000000).

3. Partition configuration:

a. Use �� keys to select 1 RAID PARAMS. Press <ENTER>.

b. Select 1.1 Array x (x=desired array) and press <ENTER>.

c. Select 1.1.1 Reconfig-RAID and press <ENTER>.

Select Yes and press <ENTER>.

d. Arrow down and select 1.1.4 Slice. Press <ENTER>.

e. Select Slice 0 and enter desired slice (partition) capacity. Press <ENTER>.

NOTE: Remaining capacity will be added to Slice 1 as a second partition.

Page 72: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 59

f . If three or more partitions are desired, repeat "Step e" for last created slice.

NOTE: Changing last slice to desired capacity will result in remaining ca-pacity being added to an additional slice.

g. Press <ESC> twice.

h. Arrow down and select 5 NVRAM. Press <ENTER>.

Select 5.1 Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

Arrow down and select 5.3 Restart. Press <ENTER>.

Select Yes and press <ENTER>.

Page 73: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

60 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

LUN Mapping

NOTE: Refer to sections "2 SCSI Params" and "5 NVRAM" of this User's Guide for furtherinformation.

1. After the array and partitions have been created, each partition needs to be as-signed a LUN and mapped to the appropriate SCSI Channel.

2. Press <ENTER> to invoke the Password screen.

3. Enter password (default password = 00000000).

4. Select 2 SCSI Params and press <ENTER>.

a. Select the SCSI channel your host server is connected to (Primary or Sec-ondary SCSI) and press <ENTER>.

b. Select 2.1.4 LUN MAP and press <ENTER>.

c. Starting with LUN 0, assign one LUN number to each partition (slice) of eacharray.

Select LUN number and press <ENTER>.

d. After selecting LUN number, select the array the partition is in and press<ENTER>.

e. Select the partition (slice) you would like to assign this LUN number to andpress <ENTER>.

Slices always start with “00” and increase sequentially according to thenumber of partitions that have been created.

5. Press <ESC> four times to return to the Main Menu.

6. Arrow down and select 5 NVRAM. Press <ENTER>.

7. Select 5.1 Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

8. Select 5.3 Restart and press <ENTER>.

Select Yes and press <ENTER>.

9. Controller will now reboot (LUN will be mapped upon reboot).

Page 74: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 61

Deleting an Array

NOTE: Refer to sections "1 RAID Params" and "5 NVRAM" of this User's Guide for furtherinformation.

1. Press <ENTER> to invoke the Password screen.

2. Enter password (default password = 00000000).

3. Deleting an array:

a. Use �� keys to select 1 RAID PARAMS. Press <ENTER>.

b. Select array to be deleted and press <ENTER>.

c. Select 1.1.1 Reconfig-RAID and press <ENTER>.

Select Yes and press <ENTER>.

d. Arrow down and select 1.1.2 RAID Level. Press <ENTER>.

Arrow down and select None. Press <ENTER>.

e. Press <ESC> twice.

f . Arrow down and select 5 NVRAM. Press <ENTER>.

Select 5.1 Update NVRAM and press <ENTER>.

Select Yes and press <ENTER>.

Arrow down and select 5.3 Restart. Press <ENTER>.

Select Yes and press <ENTER>.

Page 75: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

62 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

RAID Controller Configuration Overview

Refer to pages 62-84 for an overview of the InfoStation RAID configuration options. Thefollowing sections contain detailed information regarding each option and all their functions.

1 RAID Params

NOTE: Configuration changes made in the RAID Params menu must be saved and thecontroller restarted before changes can take effect. Refer to section "5NVRAM" of this User's Guide for further information.

5����������7� 5�5������5

5���������B

5�+������+B

5�:������:B

5�5�5������5������������� *���.�����

5�5���������� �

5�5�+����������������1$7/

5�5�:��&��

1�� �H �

6� �5� �+� ��� �6E5� +6� ��6� �1��

����� ��� ' �� ���������� �

� �� ���� �;� ����� ���I

B��������� ��� �� ���� �� ��� ����� �

5����� .�7��� �����7� & J$ ����

���/ � �����/ 5����,�� ��$..

5�)��&��' �&�I 56�:� ��5�� ���=� 5�<� �=:� �+�� �5=� �<

5���������B

5�=������=B

5�>������>B

5�<������<B

Page 76: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 63

RAID Params Menu

1.1 Array 1

This function enables the user to configure/reconfigure Array 1.

1.1.1 Array 1 Reconfigure RAID

CAUTION: Data lost during reconfiguration cannot be recovered! StorCase stronglyrecommends the user to backup all data before reconfiguring.

NOTE: To avoid accidental erasure of existing RAID configurations, Yes must beselected prior to saving any new RAID configurations.

Select either No or Yes.

1.1.2 RAID Level

NOTE: To remove an existing RAID level, reconfigure the array with RAID level None.

Select either 0, 1, 0+1, 3, 5, 30, 50, or None.

1.1.3 Disk Number

NOTES: Verify that the required number of disks for all arrays are connected beforeconfiguring an array. Refer to Table 4 for further information.

The number of disks in the array does not include the "hot spare" disk.

Select the number of disks in the RAID.

Page 77: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

64 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

1.1.4 Slice

NOTE: A slice must be mapped to a LUN before it can be accessed. Refer to section"2 SCSI Params" of this User's Guide for further information.

This function enables the user to partition the array into different slices (identified as Slice 0,Slice 1, etc.). All RAID capacity is assigned by default to Slice 0.

Input the size of each slice in MB. All RAID capacity is assigned by default to Slice 0. If Slice0 is reduced in size, all excess capacity will be automatically assigned to Slice 1, and so forth.If no capacity is allocated to a slice, then that slice will not be created.

1.2 Array 21.3 Array 31.4 Array 41.5 Array 51.6 Array 61.7 Array 71.8 Array 8

This function enables the user to configure/reconfigure Arrays 2-8 (skip these sections ifsingle array is sufficient).

1.9 Stripe Size

NOTES: Stripe size remains constant for any RAID, for both single and multiple arrays.

Smaller stripe sizes provide faster access for small randomly-accessed files.Larger stripe sizes increase transfer rates for large sequentially-accessedfiles (such as video).

Set the striping block size in either 8, 16, 32, 64, 128 (default), 256, 512, or 1024 sectors.

Page 78: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 65

1.A Write Buffer

Select either Enable (default) or Disable buffer for write operations to memory.

1.B Performance

NOTES: Sequential is best for saving large amounts of data. Random is best for savingsmaller amounts of data.

Configuration changes made in the RAID Params menu must be saved andcontroller restarted before changes can take effect. Refer to section "5NVRAM" of this User's Guide for further information.

Set writing method as either Random or Sequential.

Page 79: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

66 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Table 6: RAID Level Comparisons

Array Management

The unique RAID Controller array management firmware utilizes multi-tasking real-time kerneltechnology to manage the controller. Additional features are real-time load analysis, onlinediagnostics, event logging and broadcasting, and device inventory management.

RAID Levels

The RAID Controller supports RAID levels 0, 0+1, 1, 3, 5, 30, and 50. Depending on theapplication that will be used, each RAID level offers a difference in performance, functionality,and fault tolerance as shown in Table 6.

��������

��������� ������� ����������� ���� ���

�����6 � ��������'��-�%����$� �$������ ��-� ���' .�7��� 1�������'�� ������*��.��� ���� �.���;

�������������

�����5 � �����7����-4 ����-��' .�7��� ���������'�� �����

K����%�� �' .�7���

��-�� �$�������������*��%�� ��� ����- ���'��������� J$� �

�����+ +����* � ���������'��-%����� ����� ��'�������

�8� ���' .�7��� �.��- ;�� J$ ��������� J$ ���

������$�� ��.�������������*�� �� �� �%����''��������

&��- �'�������� ����������$''��7$��' ;���7$��� �$�� �� %�� J$ ���

������ +

����* � ���������'��-%���������/$� ��'����

� ������������' .�7��� .������������*�� �� �� �%���

4 ����-��' .�7��� ���������'�� �����

&$''����7$��' ��7$��� �$�� �� %�� �

��������/ ��'��7�I ��.��- ;�� J$ ����� J$ ���

,�� �' .�7��� ������% ����������6��������5

�����56�����6 5 +

��7/���������.�����6�2��������'��-3���������5�27����-3

��-� ����' .�7��� ���������'�� ������2������ �� 7$��' ���� �.��$ �3

��-�� �$�������������*��%�� ��� ����- ������'������ J$� �

�����+6 = ��������'��-��������%������+�����

B& ������+

��%���� ���� �.��$ ��� �������

��-�� �$������

������6 = ��������'��-��������%������������

B& �������

��%���� ���� �.��$ ��� �������

��-�� �$������

B�& ������+

��-�� �$�������������*��%�� ��� ����- ������'������ J$� �

B�& �������

��-�� �$�������������*��%�� ��� ����- ������'������ J$� �

Page 80: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 67

2 SCSI Params (For SCSI-to-SATA version only)

NOTE: Configuration changes made in the SCSI Params menu must be saved and theRAID controller restarted before changes can take effect. Refer to section "5NVRAM" of this User's Guide for further information.

SCSI Params Menu

2.1 Primary SCSI

This function enables the user to configure Primary SCSI settings.

2.1.1 Set SCSI ID

Select either 0-14 or Multiple (default =0). ID7 is reserved for the SCSI card.

2.1.2 Speed

Select either Ultra320, Ultra3, Ultra2, Ultra, or Fast. Refer to Table 7 for settings.

2.1.3 Wide

Select either Enable (default) or Disable. Refer to Table 7 for settings.

���&�&�����7� ��5����7���&�&� ��5�5��& ��&�&����

��5����&' �

��5�+��,��

��5�:���(1�#�'

�����& �������������&�&�B

��5����G�&

B��������� ��� �� ���� �� ��� ������� ����

6*5:� �#$��'

���/ � �����/

(��+�6� �(��+� (���� �(��� �"���

���/ � �����/

#�������� ���� 8�����-�����2$'����5�<��(1�3

���/ � �����/

Page 81: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

68 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Table 7: SCSI Setup

2.1.4 LUN Map

Select a LUN (0-127) and a corresponding slice to map to.

2.1.5 QAS

Select either Enable (default) or Disable.

� ������� ��� !��� ���� "��� "���#

&�&�*�

,�� �&�&�

����/

"���$

(���&�&�

(���,�� �&�&�

(����&�&�

(��5=6�&�&�

����/

���/

���/

���/

���/

L�10M

L�10M

L�10M

L�10M

L�10M

L�10M

(��+�6�&�&� ���/

"���$#%

L�10M

2.2 Secondary SCSI

This function enables the user to configure Secondary SCSI settings for use in multiple hostapplications. Submenus are the same as 2.1 Primary SCSI.

����4 ��� G�&�& ����-

���'� �

�&�

�00!

���/ �2� .�$�3

����/

1 �

Page 82: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 69

2 Fibre Params (For FC-to-SATA version only)

NOTE: Configuration changes made in the Fibre Params menu must be saved and theRAID controller restarted before changes can take effect. Refer to section "5NVRAM" of this User's Guide for further information.

���"�/ ����7� ��5����7���"� ��5�5�����/ �������������������'���

��5����& ��������������������'���

��5�+��& ������ �����������������#��

��5�:��& ����������

�����& �������������"�B

��5�����(1�#�'

B��������� ��� �� ���� �� ��� ������� ��

��+��&�1�#���

5K/��� ��K/��� �$��*1 -����� �

#�������� ���� 8�����-�����2$'����5=��(1�3

�/�����������'� �����*��*�����

��+�5��4���/ �"���������������������

BB��������� ��� �� ���� �� ������� �� �

��+����&�1�#�''��-

���/ � �����/

���/ � �����/

���/ � �����/

��+�5�5������5

��+�5���������

��+���5������5

��+�����������BB

��+���5�5�*���+���5�<& ������� & ����(1

��+�+�5�*���+�+�<& �������

��+�+�������,,1������������0�/

��+�:��4� %�,,1������������0�/

��+����4� %�&�1������������#�''��-

��+���5������5

��+�����������

H �� �1�

2.1 Primary FC

This function enables the user to configure Primary FC settings.

2.1.1 Enable Hard Loop ID

Select either Enable or Disable (default). Enable allows the user to set the ID manually. Dis-able allows the controller to set the ID.

2.1.2 Set Hard Loop ID

Enter the Hard Loop ID for this controller (Hard Loop ID must be enabled).

Page 83: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

70 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

2.1.3 Set Connection Mode

Select either Arbitration Loop (default) or Point-to-Point.

2.1.4 Set Data Rate

Select either 1 Gbit, 2 Gbit, or Auto-Negotiated (default).

2.1.5 LUN Map

Select a LUN (0-15) and a corresponding slice to map to.

2.2 Secondary FC

This function enables the user to configure Secondary FC settings for use in multiple hostapplications. Submenus are the same as 2.1 Primary FC.

2.3 SAN Mask

SAN Masking (also known as LUN Masking) is a differentiation tool for use on fibre networksbased on the unique Worldwide Name (WWN) of each fibre card. This function enables theuser to specify which hosts are able to see the RAID controller.

2.3.1 Visible for All Hosts

This function enables the user to select whether or not the RAID controller is visible toconnected hosts.

2.3.1.1 Port 1

Select either Enable or Disable. Enable allows hosts connected to Port 1 to view the RAIDcontroller.

2.3.1.2 Port 2

Select either Enable or Disable. Enable allows hosts connected to Port 2 to view the RAIDcontroller.

Page 84: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 71

2.3.2 SAN Mapping

This function enables the user to map individual LUNs to a specified host, thereby limitingaccess to certain slices to single hosts (even in dual host configurations).

2.3.2.1 Port 1

Hit Enter to proceed to 2.3.2.1.1 - 2.3.2.1.8 Select Host.

2.3.2.1.1 - 2.3.2.1.8 Select Host

Select Host 1 - Host 8, then select LUN (0-7). Select Yes or No to confirm selection.

2.3.2.2 Port 2

Hit Enter to proceed to 2.3.2.2.1 - 2.3.2.2.8 Select Host.

2.3.2.2.1 - 2.3.2.2.8 Select Host

Select Host 1 - Host 8, then select LUN (0-7). Select Yes or No to confirm selection.

2.3.3 Edit WWN Table

This function enables the user to enter individual host WWNs to the RAID controller.

2.3.3.1 - 2.3.3.8 Select Host

Select Host 1 - Host 8 and enter WWN value (default = 0000000000000000).

2.3.4 View WWN Table

This function enables the user to view a list of host WWNs in the Monitor Utility (cannot beviewed from the control panel).

Page 85: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

72 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

2.3.5 View SAN Mapping

This function enables the user to view LUN mapping to hosts in the Monitor Utility (cannot beviewed from the control panel).

2.3.5.1 Port 1

Hit Enter to view SAN Mapping on Port 1.

2.3.5.2 Port 2

Hit Enter to view SAN Mapping on Port 2.

Page 86: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 73

3 RS232 Params

+���&�+�����7� +�5��#�� 7���� +�5�5����$�����

+�5����&��'����

+�5�+����������

+�5�:�����������

+����0 7�������B

B��������� ��� �� ���� �� ��� ���� ��

�:66;�:<66;�)=66;5::66;��<<66;�+<:66;�>=66;���55��66

5� ��

1�� � �!��� ��� �

>� �<

Modem Port Menu

3.1 Modem Port

This function enables the user to set the Baud Rate, Stop Bit, Data Bit, and Parity parametersfor the modem port to match those of the modem. Refer to your modem manufacturer'sdocumentation for further information.

3.1.1 Baud Rate

Select either 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, or 115200 (default).

3.1.2 Stop Bit

Select either 1 (default) or 2.

3.1.3 Data Bit

Select either 7 or 8 (default).

3.1.4 Parity

Select either None (default), Odd, or Even.

Page 87: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

74 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Terminal Port Menu

NOTES: The RAID controller's terminal port settings must match the settings of the re-mote terminal on the host.

Flow control should be set to "NONE" on the host terminal (refer to section"RAID Management Connection Setup" and Table 1 for further information).

3.2 Terminal Port

This function enables the user to set the Baud Rate, Stop Bit, Data Bit, and Parity parametersfor the terminal port to match those of the host.

3.2.1 Baud Rate

Select either 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, or 115200 (default).

3.2.2 Stop Bit

Select either 1 (default) or 2.

3.2.3 Data Bit

Select either 7 or 8 (default).

3.2.4 Parity

Select either None (default), Odd, or Even.

Page 88: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 75

4 System Params

Password Security

NOTE: Configuration changes made in the System Params menu must be saved beforechanges can take effect. Refer to section "5 NVRAM" of this User's Guide forfurther information.

Password Info Menu

4.1 Password Info

This function enables the user to enable password security or change password.

4.1.1 Password Check

Select either Enable or Disable (default). When enabled, the user will be prompted to entera password when first accessing the main menu.

4.1.2 Set Password

Enter a password of up to 8 alphanumeric characters. Default password is 00000000.

:��&��� 7����7� :�5������%�����.� :�5�5������%�������������� ��

:�5����& ���������������%��

���/ ����/

Page 89: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

76 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Pager Alert Settings

NOTES: A modem must be connected to the RAID controller for the alert feature to work.

Configuration changes made in the System Params menu must be saved beforechanges can take effect. Refer to section "5 NVRAM" of this User's Guide forfurther information.

:��&��� 7����7� :������- ���.� :���5����-��-

:��������- �5����������1��

:������� ' ���9

:���+����- ������������1��

:���>����- �1�%

:���=����� ��

:���:�����

���/ � �����/

:�����5��0 '��� ���1��

:���+�5��0 '��� ���1��

:���+��������1��

:���:�5������5

:������������1��

:���:���������

�� �56� �5�� ��6

�� �56� �5�� ��6

Pager Info Menu

4.2 Pager Info

This function enables the user to configure pager alert settings.

4.2.1 Paging

Select either Enable or Disable (default).

Page 90: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 77

4.2.2 Pager 1 No.

Enter the first pager's terminal telephone number (also called the 'port number' or 'TAP portnumber') and the pager PIN (if required). Maximum 16 characters.

4.2.3 Pager 2 No.

Enter the second pager's terminal telephone number (also called the 'port number' or 'TAP portnumber') and the pager PIN (if required). Maximum 16 characters.

4.2.4 Code

NOTE: Pager alert messages may be up to 16 alphanumeric characters in length.

Enter the alert message for Pager 1 under Part 1. Enter the alert message for Pager 2 underPart 2.

4.2.5 Repeat

Select either 5 (default), 10, 15, or 20. This is the number of times the alert message will besent.

4.2.6 Interval

Select either 5 (default), 10, 15, or 20. This is the interval (in minutes) at which the alert messagewill be repeated.

4.2.7 Page Now

This function enables the user to send a test pager alert immediately.

Page 91: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

78 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Fax Alert Settings

NOTE: Configuration changes made in the System Params menu must be saved beforechanges can take effect. Refer to section "5 NVRAM" of this User's Guide forfurther information.

:��&��� 7����7� :�+��"�8���.� :�+�5��"�8

:�+����"�8�����

:�+�+��"�8�5�1��

���/ � �����/

5� ��

�� �56� �5�� ��6

:�+�:��"�8���1��

:�+�=��"�8�1�%

:�+����� ���9

Fax Info Menu

4.3 Fax Info

This function enables the user to configure fax alert settings.

4.3.1 Fax

Select either Enable or Disable (default).

4.3.2 Fax Class

Select either 1 or 2. This defines the Fax class supported by the modem.

4.3.3 Fax 1 No.

Enter the first Fax telephone number.

Page 92: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 79

4.3.4 Fax 2 No.

Enter the second Fax telephone number.

4.3.5 Retry #

Select either 5 (default), 10, 15, or 20. This is the number of times the alert message will besent.

4.3.6 Fax Now

This function enables the user to send a test Fax alert immediately.

Company Info Menu

4.4 Company Info

This function enables the user to configure company info on fax alerts.

4.4.1 String 1

Enter the first line of information to be used as the alert Fax header (up to 16 alphanumericcharacters maximum).

:��&��� 7����7� :�:����7'������.� :�:�5��&���-�5

:�:����&���-��

Company Info

NOTE: Configuration changes made in the System Params menu must be saved beforechanges can take effect. Refer to section "5 NVRAM" of this User's Guide forfurther information.

Page 93: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

80 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Modem Settings

NOTE: Configuration changes made in the System Params menu must be saved beforechanges can take effect. Refer to section "5 NVRAM" of this User's Guide forfurther information.

:��&��� 7����7� :����#�� 7������&� :���5��&���-�5

Modem Init St Menu

4.5 Modem Init St

NOTES: The default string is a generic string compatible with most modems. Refer tothe modem manufacturer's documentation for further information.

Configuration changes made in the System Params menu must be saved beforechanges can take effect. Refer to section "5 NVRAM" of this User's Guide forfurther information.

This function enables the user to configure the modem used for the remote notificationfeature.

4.5.2 String 2

Enter the second line of information to be used as the alert Fax header (up to 16 alphanumericcharacters maximum).

4.4.2 String 2

Enter the second line of information to be used as the alert Fax header (up to 16 alphanumericcharacters maximum).

Page 94: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 81

5 NVRAM

Saving Configurations

CAUTION: Any changes made in this menu will permanently erase data on disks! RAIDcontroller should be offline before any configuration changes are made.

NOTES: The RAID controller must be restarted for any configuration changes (in QuickSetup, RAID Params, and SCSI Params) to take effect.

Configuration changes in RS232 Params, System Params, and RAID Funcs donot require a restart of the RAID controller.

���14��# ��5��('��� �������14��#

�������� �������14��#

��+��� ����

H �� �1�

H �� �1�

H �� �1�

NVRAM Menu

5.1 Update NVRAM

Select Yes or No (default). Select Yes to store latest configuration settings in NVRAM.

5.2 Erase NVRAM

Select Yes or No (default). Select Yes to clear contents of NVRAM and restore configurationdefaults.

5.3 Restart

Select Yes or No (default). Select Yes to restart the RAID controller.

Page 95: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

82 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

6 RAID Functions

Saving Configurations

CAUTION: Initialization of an existing array will erase all data on the array!

Checking of an existing array will permanently erase on the array!

=�������"$�������

=�)����-��� ��

& ���1$7/ ��.�����

&��'� �&���

&��'� �&���

=�5������������

=������������ ��

=�:��&��'�#�� 7

=�+��� '

=������������

=�=��� 7�� �����

=�<���8'�������

=�>��&��������

& ������

& ������

1�� �H �

� �� ����/ � ����/

& �������1$7/

& �������1$7/

& ������

=�)�5�����

=�)�+���0�

=�)����&��������

H �� �1�

=�)�+�5��& ���0�

=�)�+�+��&��'��������������0�

=�)�+����&��%��������������0�

=����(����� =���5�������& .����������0 ��

=���5�5��&����������������& .�0 ��

=���5�+��&��'��������������&0

=���5�����8� �� ��������������& .�0 ��

=��������������������&�$//��-

=�����5��!� %�� ������������������

=��������&�$/�������������#��

1� H �

#��$��&�$//��- &�� �$ �&�$//��- 4� %�&�� �$

=���+�������������������

=���+�5��&������������������������

=���+�+��� '�� �����������������&�$� �����

=���+����&��'���������������������

&�$� ����� 0�- ������ &����� 7�� ������ &����&%�'��.� ����

�����5�*������5=

�����5�*������5=

=���:��&#��0 =���:�5��0 ��������������������&#��0

=���:����&#��0�������������#��

=���:�:�����������������������

=���:�+��&#��0������������������ ���0�7

& �������1$7/

����/ ���/ �2� �����3 ���/ �2� 7�� ������ 3 ���/ �2&�����%�'��.� ��� 3

=���:�:�5��4� %��������������������&���������

=6�7��� +6�7��� 5��7��� 5�7��

=���:�:����0� �������������������������.�����

=���:�:�+��0� �������������������������.��&%�'=����('��� ��!#

Page 96: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 83

RAID Functions Menu

6.1 Init Parity

This function enables the user to initialize an existing RAID 3, RAID 5, RAID 30, or RAID 50 array.

Select either Array 1, 2, 3, 4, 5, 6, 7, or 8 and then either Stop (default) or Start.

6.2 Parity Check

This function enables the user to check an existing RAID 3, RAID 5, RAID 30, or RAID 50 arrayfor errors.

Select either Array 1, 2, 3, 4, 5, 6, 7, or 8 and then either Stop (default) or Start.

6.3 Beeper

Select either Clear, Enable (default), or Disable. Clear is used to stop a sounding beeper.

6.4 Stop Modem

Select either No (default) or Yes. Select Yes to halt the transmission of subsequent alertpager/Fax messages once the message has been received and acknowledged.

6.5 Add Disk

NOTE: Add disk(s) to an existing configuration while the RAID controller is online.

Select disk number (1-12).

6.6 Remove Disk

NOTE: Remove disk(s) from an existing configuration while the RAID controller is on-line.

Select disk number (1-12). This function enables the user to shutdown a potentially faulty disk.If a spare disk is available, it will automatically be added (default = None).

Page 97: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

84 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

6.7 Statistic

NOTE: This option cannot be viewed from the Control Panel (it can only be viewed fromthe Monitor Utility).

This function enables the user to display system data. Data includes:

• Current settings saved in NVRAM• Statistical analysis of read and write operations, plus the percentage of cache hits

6.8 Expand Array

CAUTION: Data may be lost during the expansion process! StorCase strongly recommendsthe user to backup all data before expanding.

NOTE: Make sure that new disk capacity is equal to or larger than the current onlinecapacity.

Select array to be expanded (Array 1-8), then the number of disks in the new array.

To expand disk capacity:

1. Connect new disk.

2. Use Expand Array menu to select the number of disks in the array.

3. Go to the 1.1.4 Slice menu. The new capacity should appear as a new slice. If noslices were created previously, the new capacity will appear as Slice 1.

6.9 Log Event

6.9.1 Erase

This function enables the user to erase the event log.

6.9.2 Statistic

Page 98: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 85

6.9.3 RTC

NOTE: When using the RAID controller for the first time, users will need to set the RTCParameters. Setting the RTC parameters will enable the RTC function on thecontroller. When an event occurs, the Log Event wil then be able to record theevent in real-time.

This function enables the user to adjust real-time clock settings.

6.9.3.1 Set RTC

Enter the time in MM/DD/YY W HH:MM format.

(MM = Month, DD=Day, YY=Year, W=Week, HH=Hour, MM=Minute)

6.9.3.2 Show RTC

Select to have time displayed on control panel.

6.9.3.2 Stop RTC

Select to turn off RTC.

6.A. Utility

6.A.1 Disk Self Test (DST)

This function enables the user to detect the disk's status.

6.A.1.1-6.A.1.2 Short Self Test or Extended Self Test

Select one of the two functions to do all disks or Disk 1-16 detection.

Page 99: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

86 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

6.A.1.3 Stop DST

6.A.2 Disk Scrubbing

NOTES: For disk scrubbing to start, the array must be at its optimum. There cannot beany failed member disks or background tasks (such as adding a disk or ex-panding an array).

Once disk scrubbing starts, the user cannot start any other background taskand array cannot be deleted.

This function enables the user to prevent unrecoverable data loss, recover bad blocks, andfix parity errors.

Disk scrubbing provides the following advantages:

1. Disk scrubbing will not prevent normal host access. It will slow down the system'soverall performance however.

2. Disk scrubbing can be started and processed simultaneously for multiple arrays.

6.A.2.1 Overwrite Parity

Select either No (Default) or Yes. Select Yes to overwrite parity if inconsistency is detectedduring disk scrubbing.

6.A.2.2 Scrub Mode

6.A.2.2.1 Manual Scrubbing

This function enables the user to select one array or all arrays to start disk scrubbing. Thisfunction also enables the user to stop disk scrubbing at anytime.

Page 100: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 87

6.A.2.2.2 Schedule Scrubbing

NOTES: If the array is not at its optimum, the controller will cancel disk scrubbing andrecord this event in the event log.

If the InfoStation is not ON at the time of a scheduled scrub, disk scrubbing willnot occur and controller will record this event in the event log.

This function enables the user to schedule disk scrubbing for one array or all arrays.

If enabled, the user can then select Once, Once per week, Once per 4 weeks, Once per8 weeks, Once per 12 weeks, Once per 16 weeks, Once per 20 weeks, or Once per24 weeks to schedule disk scrubbing.

6.A.2.2.3 View Schedule

This function enables the user to check the disk scrubbing schedule.

6.A.3 Disk Clone

NOTES: For disk cloning to start, the array must be at its optimum. There cannot beany failed member disks or background tasks (such as adding a disk or ex-panding an array).

Once disk scrubbing starts, the user cannot start any other background taskand array cannot be deleted.

Disk cloning, like mirroring, prevents failure of disks from data loss and unscheduled per-formance degradation.

Disk cloning provides the following advantages:

1. Disk cloning will not prevent normal host access. It will slow down the system'soverall performance however.

2. Disk cloning can be started and processed simultaneously for multiple arrays.

6.A.3.1 Start Disk Clone

This function enables the user to start disk cloning.

Page 101: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

88 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

6.A.3.1.1-6.A.3.1.2 Source Disk and Target Disk

NOTE: Make sure that target disk capacity is equal to or larger than the source diskcapacity. Disk cloning will not occur if target disk is smaller than the sourcedisk.

Select the desired source disk from the displayed array member, as well as desired targetdisk to be cloned.

6.A.3.1.3 Start Permanent Clone

Select either Yes or No.

Once background copying is done, disk cloning will remain in a state of mirroring. Select Yesfor controller to keep both disks synchronized permanently and replace source disks whennecessary.

6.A.3.1.4 Start Swap after Clone

The source disk array will be replaced by the clone disk, and taken offline.

6.A.3.2 Stop Disk Clone

This function enables the user to manually stop disk cloning.

6.A.3.3 Replace Source Disk

This function enables the user to manually replace the source disk by the clone disk oncebackground copying is done. Disk will remain in a state of mirroring.

6.A.4 SMART

SMART (Self-Monitoring, Analysis, and Reporting Technology) protects user data andminimizes the likelihood of unscheduled system downtime that may result from predictabledegradation and/or drive fault. By monitoring and storing critical performance and calibrationparameters, SMART drives attempt to predict near-term degradation or fault conditions.Providing the host system with such data allows the host to warn the user of impending riskof data loss.

Page 102: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

RAID Controller Configuration 89

6.A.4.1 Test Disk SMART

This function enables the user to check if a disk supports SMART and the current status ofone disk or all disks.

6.A.4.2 SMART Mode

Select Disable to disable the SMART function for all disks.

Select Enable (Alert only) to enable the controller to check status of all disks. An audiblealarm will sound in the event of a SMART warning.

Select Enable (Permanent Clone) to enable controller to select one spare disk and one clonedisk in the event of a SMART warning. Once disk cloning is done, the source disk will remainin a state of mirroring without replacement.

If there is no spare disk, disk cloning will not occur.

Select Enable (Start Swap after Clone) to enable controller to select one spare disk andone clone disk in the event of a SMART warning. Once disk cloning is done, the source diskwill remain in a state of mirroring with replacement.

If there is no spare disk, disk cloning will not occur.

6.A.4.3 SMART Check Time

Select the desired length of time (60 min/30 min/15 min/1 min) needed to execute the SMARTfunction.

6.A.4.4 Bad Blocks

6.A.4.4.1 View Statistics

This function enables the user to view disk status.

Page 103: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

90 RAID Controller Configuration

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

6.A.4.4.2 Threshold for Clone

NOTE: The number of thresholds for clone must be smaller than the thresholds forswap.

Select the number of bad sectors (Disable/2 per GB/3 per GB/5 per GB/10 per GB) neededto execute disk cloning.

6.A.4.4.3 Threshold for Swap

NOTE: The number of thresholds for swap must be larger than the thresholds forclone.

Select the number of bad sectors (Disable/3 per GB/5 per GB/8 per GB/14 per GB) neededto execute disk cloning.

6.B Update ROM

CAUTION: Shutdown the host computer system(s) before updating the firmware.

NOTE: Array data and configurations are not affected by this function.

This function enables the user to update the RAID controller's firmware.

Page 104: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix A - Specifications/Dimensions 91

APPENDICES

Page 105: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

92 Appendix A - Specifications/Dimensions

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

The following InfoStation specifications and dimensions are provided for reference only.

Appendix A - Specifications/Dimensions

�&���������� �������� ���'�����

������ ���� ������������ ������ �������

����� ������� ������

��

(����������������� ��������

)�������� ��������7/� ���0 7' ��$ ������������ ������������������ !��"���#�����$� �� ��%������% ��%�����%

& ���#�� �����������'����(� �����������'����(�������������� ������������

)��*+ �� ��� ���

��,�-�*�-��-.�-��/�����!0��#���1!���-���(���%���1���#1

������.�*��# .��/������2��.�-��/!"�

������ ���� 3.� ����+��

��������(�����$�*�!..�.�� -���1�"�.��-.�! ���

(������������ ��������2' �:=6,���% �&$''��#��$ 3

&��4-�#�

���5#��#�

&���������������*��������������

6789 ���'������#1.

:1�"�-��"�6!�-��-!-*�

:�/�1�)#�� $�6��# �

�����������;&�'��2���<

;�!����&'���;�!����&

9!-�6��# �

�����96

����� ��1�9!-�6��# ��

��

Page 106: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix A - Specifications/Dimensions 93

���� ������ ��������� �*+

(��+�6*��*&�0������#�$��������$ ������������ ���� &56�56<�N�&56�55�����

9��.���� ��&$''�� � 5�

9��.����������� 5

9��.���� ���� �����$� � � 5�

#�8��9��.���� ��&$''�� � � � 5�

#�8��&���- ���'�����C ������2��� �������6K��& ����0����� �3 +�6�0�B2��� �������6K��(����0� 566���� �3 +�6�0�B

����&%�''�/ ���� � H �����&���$����������� H �

�������� .�� C �������

&�&�������� (��+�60���. ���� +�6#� � ����� ����0�' ��=<

�������� .�� C & ����0���(����0� 566

0���. ���� 2& ����0�3 5��K/'�2(����0� 5663 566#� � �

9��.���% �&$''��#��$ �C �

� �$����� H �����&%�''�/ H �

9��.������-�#��$ �C �

� �$����� H �����&%�''�/ H �&' �*4���/ �$��"��� ��"��� #��$

* OS limitation is 2.0 TB maximum. However, multiple arrays can be created to a-chieve over 2.0 TB capacity (e.g. one array with 2.0 TB, the other array with 1.0 TB,or a combination thereof).

Page 107: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

94 Appendix A - Specifications/Dimensions

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

* 3-year limited warranty on Power & Cooling Modules

���� ������ �������� �*+

(��+�6*��*&�0������#�� ������$ � &56�56<�N�&56�55�

������������

������ � �&$''��C 6;�5;�6 5;�+;��;�+6;������6#�8��� ��� ��&$''�� �C 5�#�8��9��.����� <#�8��9��.��(1� 5�<

!��� ���'�������8'������2!��3�&$''�� �C H �

� ����� � K�/��&'� �&$''�� �C H �"�8 ��- �1���.�������C H �,�� �!'�����C ,�� �0��$-����,�� �����

����������

��7���������(�����C 4����&*�+������1&�����'���0 7����2����3����#��� �&���- �#���- �K(�

"$�������C � �� �����;������ ���.�-$�����;�$��7���������&%�';�����&'� ;��� �� /$��;���- "�?�1���.�������

,���-�����������

���� �# 7��C 5�<#�;��66*'������566�����&!��##���� ������*$' !'�����

�8� ���#�������-�(����� H ������&*�+�����

�$��/ ���7 H �

&�������5)������*#�$�� � �-���D�:(

0 �������&$''�� 0�*"

��7�� ��,����� >�H ��B

� -$������''����

�#� "�� �� �*����&�. ����- ��� �&� �&��O(&� 0(4

0#

Page 108: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix A - Specifications/Dimensions 95

���� ������ �������� �*+

"�*��*&�0������#�$��������$ ������������ �������� &56�56��N�&56�56:

9��.���� ��&$''�� � 5�

9��.����������� 5

9��.���� ���� �����$� � � 5�

#�8��9��.���� ��&$''�� � � � 5�

#�8��&���- ���'�����C ������2��� �������6K��& ����0����� �3 +�6�0�B2��� �������6K��(����0� 566���� �3 +�6�0�B

����&%�''�/ ���� � H �����&���$����������� H �

�������� .�� C "�*�������� "�/ ������ 0���. ���� �K/'�#�8��9��.�"�����'� �

�������� C���2�'����3 �K/'� 5K/'�

#�8�7$7���/ �� �-��C���2�'����3�*� =��� 5����7 5�67�2�K/'�3� �+667�25K/'�3

�6 5����7 +667�2�K/'�3� ��667�25K/'�3

!'�����,�� �-�� <�6��7

�������� .�� C & ����0���(����0� 566

0���. ���� 2& ����0�3 5��K/'�2(����0� 5663 566#� � �

9��.���% �&$''��#��$ �C �

� �$����� H �����&%�''�/ H �

9��.������-�#��$ �C �

� �$����� H �����&%�''�/ H �&' �*4���/ �$��"��� ��"��� #��$

Page 109: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

96 Appendix A - Specifications/Dimensions

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

* 3-year limited warranty on Power & Cooling Modules

���� ������ �������� �*+

"�*��*&�0������#�� ������$ � &56�56��N�&56�56:

������������

������ � �&$''��C 6;�5;�6 5;�+;��;�+6;������6#�8��� ��� ��&$''�� �C 5�#�8��9��.����� <#�8��9��.��(1� 5�<

!��� ���'�������8'������2!��3�&$''�� �C H �

� ����� � K�/��&'� �&$''�� �C H �"�8 ��- �1���.�������C H �,�� �!'�����C ,�� �0��$-����,�� �����

����������

��7���������(�����C 4����&*�+������1&�����'���0 7����2����3����#��� ����&���- �#���- �K(�

"$�������C � �� �����;������ ���.�-$�����;�$��7���������&%�';�����&'� ;��� �� /$��;���- "�?�1���.�������

,���-�����������

���� �# 7��C 5�<#�;��66*'������566�����&!��##���� ������*$' !'�����

�����/$� ��������7 ����#�������- H �

�8� ���#�������-�(����� H ������&*�+�����

�$��/ ���7 H �

&�������5)������*#�$�� � �-���D�:(

0 �������&$''�� 0�*"

��7�� ��,����� >�H ��B

� -$������''����

�#� "�� �� �*����&�. ����- ��� �&� �&��O(&� 0(4

0#

Page 110: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix A - Specifications/Dimensions 97

Figure A-1: InfoStation Physical Dimensions(Dimensions are for reference only)

.������-

���&����������-���������-

=�)�25>=��773

5)�<)2�6���773

5=�)�2:�)�<773

5<�)<2:<��5773

Page 111: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

98 Appendix B - Optional Accessories

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

�"&5:@�)

D

D

DDDDDD

Figure B-1: Rack Mount Slide Rail Kit

Appendix B - Optional Accessories

Slide Rail Kit

The optional slide rail kit (P/N DXRCK-SLIDE) provides a convenient method to attach theInfoStation to a rack mount enclosure (Figure B-1). These high quality, durable rails provide24 ball bearing rollers and have a quick-release button which allows quick and easy installationand removal of the InfoStation unit from its rack enclosure. Contact StorCase for furtherordering information.

Page 112: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix B - Optional Accessories 99

Figure B-2: RAID Controller Memory Module

RAID Controller Memory Modules

512MB and 1GB 200-pin DDR266 SODIMM memory modules (P/Ns S10E104 & S10E105) areavailable to increase the InfoStation RAID Controller's cache memory (Figure B-2). ContactStorCase for further ordering information.

Page 113: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

100 Appendix B - Optional Accessories

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Optional Power Supply Module

CAUTION: The power supply module contains NO USER SERVICEABLE PARTS inside theunit. Warranty is VOID if module is opened. Refer ALL servicing to qualifiedservice personnel!

NOTE: Refer to the InfoStation Installation Guide for further information.

A replacement 460W power supply module (P/N S10H104) is available for the InfoStationchassis as shown in Figure B-3. Contact StorCase for further ordering information.

Figure B-3: Power Supply Module

Page 114: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix B - Optional Accessories 101

Replacement Fan Module

CAUTION: The fan module contains NO USER SERVICEABLE PARTS inside the unit.Warranty is VOID if module is opened. Refer ALL servicing to qualified servicepersonnel!

NOTE: Refer to the InfoStation Installation Guide for further information.

A replacement fan module (P/N S10H105) is available for the InfoStation chassis as shownin Figure B-4. Contact StorCase for further ordering information.

Figure B-4: Fan Module

Page 115: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

102 Appendix B - Optional Accessories

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Drive Carrier

Spare drive carriers (P/Ns S10B100 & S10J100) are available for the InfoStation chassis asshown in Figure B-5. Contact StorCase for further ordering information.

Figure B-5: Drive Carrier

SFP Module (For FC-to-SATA version only)

Spare LC (optical) SFP Modules (P/N S10D114) are available for the FC-to-SATA RAID Info-Station chassis as shown in Figure B-6. Contact StorCase for further ordering information.

Figure B-6: LC (optical) SFP Module

Page 116: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix B - Optional Accessories 103

Carrying Case(Figure B-7)

The optional molded plastic carrying case (P/N S20E101) is designed to transport the Info-Station drive carrier from one site to another in a safe, impact and moisture resistantenvironment. Its compact design makes it easy to carry and store. The foam lining is contouredto fit a single InfoStation carrier. Contact StorCase for further ordering information.

Figure B-7: Carrying Case

+�6",@5+

Page 117: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

104 Appendix B - Optional Accessories

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

RAID Battery Backup Kit

NOTE: This a factory-installed option. Contact StorCase for further information.

RAID battery backup kits are available for the InfoStation chassis as shown in Figure B-8.Contact StorCase for further ordering information.

���� ��#��$ ���� ����� 7/�

56*%� ��/

��//����/

Figure B-8: RAID Battery Backup Kit

Page 118: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix B - Optional Accessories 105

InfoStation Monitoring Utility (InfoMon®)

InfoMon is a web-based monitoring utility that runs under the Windows O/S. This free utility(and its accompanying User's Guide) is available for download at the StorCase web site(http://www.storcase.com).

The primary purpose of InfoMon is to continuously monitor the environmental status andindicate alarm conditions inside the InfoStation chassis via a serial connection to a PC. InfoMonalso provides the User the ability to easily configure both device and chassis settings witha few clicks of the mouse!

In addition, InfoMon allows the User to monitor the statuses and temperatures of individualInfoStation modules and drive bays, etc., and can provide "real-time" updates via an Internetconnection. With the recent addition of the InfoMon Call Home™ feature, this information canalso be sent to a specific site for access by StorCase technical support staff in order to assistwith system troubleshooting. The Call Home feature also provides the ability to set-up a pagingfunction for notification of environmental alarm or warning conditions.

To install and operate the InfoMon software, the computer system must meet the followingrequirements:

Operating System: Microsoft® Windows® 95/98/NT/2000/XPCPU: IBM-compatible 486 or higherMemory : 32MB RAMHard Disk Space: 12MBInternet Connection: Required only if monitoring via the webInternet Browser: Microsoft Internet Explorer 5.0 (or higher) or

Netscape Communicator 4.7 (or higher)

Page 119: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

106 Appendix C - Troubleshooting

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Appendix C - Troubleshooting

StorCase Technical Support

For assistance configuring and using this StorCase product, contact StorCase technicalsupport at (888) 435-5460.

Setup Problems

• Unable to access the RAID Controller after OS boots up.

Cause - The RAID Controller might not be configured.

Fix - Verify that the RAID Controller is configured for a RAID level. If no RAID level isconfigured, the OS will not detect the RAID Controller as a disk.

• Unable to recognize the disks.

Cause - There might be a disk drive jumper setting problem.

Fix - Verify that all drive jumpers are set to "Master".

• Unable to setup an array using Quick Setup.

Cause - Quick setup can only be used to set up new RAIDs. If the error message 'Array 1Exists!' appears, an array has already been configured.

Fix - Reconfigure the array from the RAID Params submenu.

Page 120: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix C - Troubleshooting 107

Operation Problems

• The front panel LCD displays alternating "Zz" characters.

Cause - This occurs when the cache is full of write request data that has not been processed.The controller will halt requests from the host to flush out data in the cache.

Fix - None required.

• The front panel LCD displays alternating "Ww" characters.

Cause - This occurs when write requests in the cache are being processed. The controllerwill also halt requests from the host.

Fix - Verify that the "Write Buffer" option in the RAID Params Menu is enabled. Increasecache memory if needed.

• The front panel LCD displays "OWOOOS".

Cause - This occurs when there are many bad sectors on a disk drive.

Fix - Change the disk drives.

• Invalid NVRAM message appears.

Cause - NVRAM error or malfunction.

Fix - Save settings and restart controller. Contact StorCase Technical Support if theproblem persists.

• Data loss in Windows 2000 during system shutdown.

Cause - Some data was still in cache buffer during system shutdown.

Fix - Set Cache Off. To shutdown, select Restart System and wait for 30 seconds beforepowering off. Shutdown host OS after shutting down controller.

Page 121: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

108 Appendix C - Troubleshooting

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Remote Terminal Problems

• Unable to access the Configuration Mode using the remote terminal (MonitorUtility).

Cause - The terminal communication settings might not match the settings of the RAIDController.

Fix - Verify that the terminal communication settings of the remote terminal and the RAIDController match. Default settings for the RS-232 port is 19200 Baud, 8 Data Bits,1 Stop Bit, and NO Parity.

Alert Message Problems

• Unable to send a Page or FAX using the MODEM port.

Cause - The Page and FAX options might not be enabled, or the default modem initializationstring may not be compatible with your modem.

Fix - Verify that the Page and FAX options are enabled. Change the modem initializationstring to match your modem (refer to your modem manufacturer's documention forfurther information).

The following modem models require their own initialization strings:

���������� �������/������������ 0������� ��1� ���

#�����#�� 7&(�"�4�+:��<�<

#$��� ��#$��7�� 7�<+:A�?

��� ����$���<<4�+:�E�"�?

��������� �'� ���#5::#0���

K4�"*55�<4 0�

(&���/�����&'���� ��<<66

�0N�RG5�

�0N�6N���6

�0N�6N�:�6

�0N�:

�0N�6N�5N��

�0N��N�5N�5N�5

('����+<:66

('����+<:66

+<:66����

('����+<:66

+<:66����

+<:66����

5�N��

�����

5�N��

�����

5�N��

5����

Page 122: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix C - Troubleshooting 109

SCSI Problems (For SCSI-to-SATA version only)

• The RAID Controller is not properly identified by the SCSI adapter duringinitialization of the computer system.

Cause - SCSI ID set for the RAID Controller could be the same ID used by another SCSI deviceattached to the same SCSI host adapter.

Fix - Select a different SCSI ID for the RAID Controller. Most SCSI host adapters provideonboard ROM BIOS (or software utility) that displays attached devices and their SCSIIDs. Disconnect the RAID Controller from the SCSI host adapter during system bootand note the SCSI IDs already in use.

• The RAID Controller is identified at all SCSI IDs.

Cause - SCSI ID set for the RAID Controller could be identical to the reserved SCSI ID usedby the SCSI host adapter.

Fix - Configure the RAID Controller to a different SCSI ID. Most SCSI host adapters reserveSCSI ID7.

• The RAID Controller is not detected by the SCSI host adapter.

Cause - Incorrect termination in the daisy-chain configuration, or possibly a loose SCSIcable.

Fix - For daisy-chain configurations, verify that only the SCSI host adapter and the lastSCSI device is terminated.

Page 123: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

110 Appendix C - Troubleshooting

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Error Messages

Error events alert the user of any failures associated with the controller, disk drives, orchassis. When an error event occurs, the problem should be corrected IMMEDIATELY. TableC-1 defines error messages and likely causes.

Table C-1: Error Messages

(������������ �����������

1$7/ ��.������.�$���D��;�� � ��D�I

1$7/ ��.�������.�$���2�3��� ������7������� ��$7/ ��.���������.�-$ ��.����1$7/ ��.�������2I3���� J$� ��

�����8���������� �S �����283������������� �������$��/ ����/ ���� �� ��

�����8�' ���$�� 7�� �S �����283�%��� 7�� ���$ ������.�� ���������/��$� �

0���7��������7 7/ ��.�� �S

0� �7���7$7��$7/ ��.������� J$� ��.���� ���������.�-$�����.�� ������������I �

������������.�-$ �S ������������/ ����.�-$ ���$ ���������.�-���������������/ ���������������/ �����.�-$ ��

�����8�.�7������!�S �����283�.�� ���$��-�.�7����������/ �/��������

��������������!�S ��������������I������.�� ���������/ �/����������(� �������� ������� ���.��.�$��������

�����8��������!�S �����283�/ ��-���� ��.�� ���������/ �/����������(� �������� ������� ���.��.�$��������

���������!�C�/���2�3S��'�����/�� �%���$��/ ���� �� %�� ������2�3������ �/����2� ���3����� ������������.�� ���������/ �/��������

��������� ������!�S 0� ������ ���.$�������.�� ���������/ ����� �����������.�-$*�������������������I ��

Page 124: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Appendix C - Troubleshooting 111

(������������ �����������

��@���@�7�C�%������G 0� �������� .�� ����%�����-�.����G���-������-���..������77���'��� �

��@���@�7�C���!��2�3S

��� ��2�3����$ ������������ .�� ���(� �������� �������� ���.�.�$������������� �

���@�&�C%����#��� ���� ������� .�� ����%�����-�.�������� $'��.�7��������

���@�&�C%���������$����.. ������� .�� ����%�����-�.����������/ �. �

���@�&�C�&���$��2�3 ������������ ��$ �������$��2�3�

���@�&�C�%������G ,�����-�.���������� �����$���..���G������� $'��'��� �

���@�&�C���G�!1 ������� ����G��������. ������� $'��'��� �

��&�C�����$��2�3;���!��2/3S

&���$��2�3����� ��2/3� �$� ��/���� ������/�� ������0�*�&' ��.��������

��&�C�98��' D�;�/���D/;� ���D�

�����283�.�� ����� �'��������� J$ ���/���� ������ �2�3�������$7/ �2/3�%� ��� � J$ ���.�� ������ 7�����-�� �����2�3�

��&�C��������I �98���!�S

�����283�%���$��/ ����/ ��������I ��/���� ������ ��������/ /��������

��&�C��������I �98����..�� S

�����283�.�� ������%��� 7�� ��.�7��� ���������.�-$������

��&�C�98���������� �S �����283��������� � �� ��/���� ������ ��������/ �/��������

��&�C�98����!�����$��2�3S

�����283���$� ����� ����0� �����$��2�3� �$� ��/���� ������' �0�*��&' ��.��������

���!�C��1������������S

����� ��� ������ ��-��I ��� �� ��� ������ ��

���!�C������'��7 � �����!�S

����� �%���$��/ ���� ����� ������'��7 � ��2����� ;�� ���;� ����;�7$��*� ���3��������/ �/��������

���!�C��1�7$��*� ����7�� S

������� �������$''����� ��0�*��7$��*� ��������. �.$�������������������� ����������

���!�C���!��H�����$''�� �S

������� �������$''����� ��0�*��7$��*� ��������. �.$�������������������� ����������

��&�C�92�3�� 7�'� ���� .�%S 0� �� ��$� ����� *7�'�/���� ��������.$�

��&�C�92�3������C2/3��� *7�'' �

������$7/ �2/3���� � �� �������/���� ������������/ � *7�'' ��

��&�C�92�3������C2/3��� *7�'' �

1�� *7�'�� ������ ������/ �%�� ��� ������ �� � �� ��/��� �����

Table C-1: Error Messages (cont'd)

Page 125: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

112 Appendix C - Troubleshooting

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

Table C-1: Error Messages (cont'd)

(������������ �����������

���7�� 7��' ������� ����� �S (� ����'' ��7�� 7�.�7�� ����-���'�- ���"�?�����.��������

0�����-�"���S "�?������5��$''���*�7�� 7�.�� ���$��-�������-�'��� �

��- �����. ��"���S ��- �����.��������.�� ����#�� 7�7���/ �!""���������� �� ��

"�?C�#�� 7����/$��S #�� 7�����$ �������$� �����$��/ ����� ���"�?�����.��������

��-��-C�#�� 7����/$��S

�������14��# ��.�7��������� �����14��#�� ����������������$��/ ����/ �$� ��

1�����.�-$����� ���������� �����$ ����$����.�-$ ��.����������� � �

���.�-����!� �$ ������.�-$������.�� ��� �.���������������/ �/���������������..�� �

1��� ��$-������ 1$7/ ��.������� J$� ��.���� ������ � ����7�����-��������/ /������������������..�� �

"����"�� ��������/�% �.��$ �

,��1�0 7' ����� �� 7' ��$ ��.���������������-��

#�� 7�����$ �������$� �����$��/ ����� ���'�- �����.��������

Page 126: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

InfoStation 12-Bay RAID User's Guide - Rev. D00 StorCase Technology, Inc.

Reader's Comments 113

Reader's Comments

Please take a few moments when your computer system is up and running to send us yourideas and suggestions for improving our products and documentation. Did the installation gosmoothly for you? Are there any changes you would like us to make, either with the hardwareitself, or with the installation instructions? Everyone at StorCase Technology is workingtoward the goal of providing you with the highest quality, most cost effective, productsavailable on the market, and we need your comments to guide our efforts. We look forwardto hearing from you soon!

Date:

Your Name:

Address:

Telephone: ( )

To mail this page, carefully remove it from the manual, fold it, staple or tape it shut, and dropit in the mail. To FAX this page, carefully remove it from the manual (or make a photocopy) andFAX it to us at (714) 438-1847. Thank you for taking the time to help us make our productsbetter!

Page 127: StorCase Technology · PDF file12-Bay Ultra320-to-Serial ATA RAID 12-Bay FC-to-Serial ATA RAID ... StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide ... Refer all servicing

114 Reader's Comments

StorCase Technology, Inc. InfoStation 12-Bay RAID User's Guide - Rev. D00

FOLD ALONG THIS LINE AND STAPLE SHUT

CU

T A

LON

G T

HIS

LIN

E F

RO

M B

OT

TO

M T

O T

OP

OF

PA

GE

B U S I N E S S R E P LY M A I LPOSTAGE WILL BE PAID BY ADDRESSEE

NO POSTAGENECESSARY

IF MAILEDIN THE

UNITED STATES

FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA

TECHNOLOGY CORPORATION

17600 NEWHOPE STREETFOUNTAIN VALLEY CA 92708-9885