Standard Washer Box EZOut Features: TM...up test cap. 3 4 ROTATE HERE TheDU•ALLDualDrain Design...

2
Web Site: www.ipscorp.com E-Mail: [email protected] The DU ALL TM Dual Drain Washing Machine Outlet Box Featuring EZ Out TM Test Cap 500 Distribution Parkway, P.O. Box 220, Collierville, TN 38027, USA TEL: 901-853-5001 WATS: 800-888-8312 FAX: 901-853-5008 BB12033 Added Du•All Dual Drain Features: Various valve mounting options allows dual drain, right drain only or left drain only Box can be inverted for top mount valves /center drain option EZ Out Test caps are raised for EZ removal and KO’s are oversize so they won’t fall down the drain Key Dual Drain Features: Solid one piece construction with raised drip guard contains and sends valve or washing machine hose leaks down the drain Forward mounted valves give easy access to homeowners for on/off operation Drains positioned toward back of box for connection to trap from either side Standard Washer Box Features: Our one piece design speeds installation vs separate drain and valve boxes Depth of the box rests against the back sheetrock wall for sturdy installation Side of the box has a flat side for secure mounting to wall The frame is interchangeable with center drain washing machine outlet boxes 2 5 4 3 6 1 3 2 4 6 5 1 ®

Transcript of Standard Washer Box EZOut Features: TM...up test cap. 3 4 ROTATE HERE TheDU•ALLDualDrain Design...

Page 1: Standard Washer Box EZOut Features: TM...up test cap. 3 4 ROTATE HERE TheDU•ALLDualDrain Design Gives Flexibility of Valve Mounting Options Arrester Valve Left, Right Drain Top Mount,

Web Site: www.ipscorp.comE-Mail: [email protected]

The DU•ALLTM Dual DrainWashing Machine Outlet BoxFeaturing EZ•Out TM

Test Cap

500 Distribution Parkway, P.O. Box 220, Collierville, TN 38027, USATEL: 901-853-5001 ■ WATS: 800-888-8312 ■ FAX: 901-853-5008

BB12033

Added Du•All Dual DrainFeatures:Various valve mounting optionsallows dual drain, right drain only or left drain onlyBox can be inverted for top mount valves/center drain optionEZ Out Test caps are raised for EZ removal and KO’s are oversizeso they won’t fall down the drain

Key Dual Drain Features:Solid one piece construction with raised drip guard contains andsends valve or washing machinehose leaks down the drainForward mounted valves give easyaccess to homeowners for on/offoperationDrains positioned toward back of box for connection to trap from either side

Standard Washer BoxFeatures:Our one piece design speeds installation vs separate drain and valve boxesDepth of the box rests against the back sheetrock wall for sturdy installationSide of the box has a flat side for secure mounting to wallThe frame is interchangeable with center drain washing machine outlet boxes

2

5

4

3

6

1

3

2

4

6

5

1

®

Page 2: Standard Washer Box EZOut Features: TM...up test cap. 3 4 ROTATE HERE TheDU•ALLDualDrain Design Gives Flexibility of Valve Mounting Options Arrester Valve Left, Right Drain Top Mount,

Hit screwdriver until it penetrates under test cap.

1 2

Position flathead screwdriver at intersection wall and raised test cap.

of bottomReach in with hand or pliers and remove test cap.

Rotate screwdriver lifting up test cap.

43

ROTATEHERE

The DU•ALL Dual DrainDesign Gives Flexibility of Valve Mounting Options

Arrester Valve Left, Right Drain

Top Mount, Single Drain

Valves Right, Left Drain

Top Mount, Single Drain

TM

VALVE CONNECTIONS ProPEX® is a registered trademark of Uponor/WirsboKITEC® is a registered trademark of IPEX, Inc.

EZ•OUT TM

Test Caps Are Raised Up for EZ Removal

Valves Forward w/ Auxiliary DrainLine & Washer Discharge Line

PEX Crimp ProPEX® Hammer ArrestersPEX F2080Kitec® PEX CPVC Copper

1/2" Sweat1/2" Female

Socket3/8" or 1/2"Available in 1/4 turn

or Single Lever

Other

InstallationUses

DU•ALLTM

Valves Forward w/Dual Drain

Top Mount w/ single Drain

Valves Forward with Studor AAV& Washer Discharge Line