AB ANCHOR BOLT ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE AD AREA DRAIN ADD'L ADDITIONAL ADJ ADJUSTABLE ADMIN ADMINISTRATION AEWC ACCESSIBLE EWC AFF ABOVE FINISHED FLOOR ALUM/AL ALUMINUM ALT ALTERNATE ANCIL ANCILLARY ANOD/AN ANODIZED APPROX APPROXIMATE(LY) ARCH ARCHITECT(URAL) AWI ARCH'TL WOODWORK INSTITUTE BD BOARD BFF BELOW FINISHED FLOOR BLDG BUILDING BLK BLOCK BLK'G BLOCKING BM BEAM B.O BOTTOM OF BEARING BRG BRK BRICK B.S. BOTH SIDES CAB CABINETS CF/CI CONTRACTOR FINISHED, CONTRACTOR INSTALLED CFMF COLD FORMED METAL FRAMING CL CENTERLINE CLR CLEAR CJ CONTROL JOINT CLG CEILING CLO CLOSET CMU CONCRETE MASONRY UNIT COL COLUMN COMP COMPOSITE, COMPOSITION CONC CONCRETE CONF CONFERENCE CONST CONSTRUCTION CONT CONTINUOUS CORR CORRIDOR CPT CARPET CR COLD ROLLED CRS COURSE CT CERAMIC TILE CTR CENTER CTSK COUNTERSINK CU.FT. CUBIC FOOT CU.YD. CUBIC YARD DBL DOUBLE DEG DEGREE DEPT DEPARTMENT DF DRINKING FOUNTAIN DET DETAIL DIA DIAMETER DIM/DIM'S DIMENSION(S) DISP DISPENSER DIV DIVISION DN DOWN DR DOOR DWR DRAWER LIST OF ABBREVIATIONS DWG/DWG'S DRAWING/DRAWINGS E EAST EA EACH EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENCL ENCLOSURE ENGR ENGINEER EQ EQUAL EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EXG/ EXIST EXISTING EXP EXPANSION EXPO EXPOSED EXT EXTERIOR FA FIRE ALARM FCU FAN COIL UNIT FD FLOOR DRAIN FDN FOUNDATION FF FINISHED FLOOR FE FIRE EXTINGUISHER FEB FIRE EXTINGUISHER BRACKET FEC FIRE EXTINGUISHER CABINET FIN FINISH FLEX FLEXIBLE FLR FLOOR FLASH or FLG FLASHING FR FIRE RATED FRM FRAME FRT FIRE RETARDANT TREATED FT FOOT or FEET FTG FOOTING FURN FURNISHED FURR'G FURRING FV FIELD VERIFY GA GAUGE GALV GALVANIZED GB GRAB BAR GEN GENERAL GI GALVANIZED IRON GL GLASS GLAZ GLAZING GND ELECTRICAL GROUND GR GRADE GYP GYPSUM HC HOLLOW CORE or HANDICAP ACCESSIBLE HDW HARDWARE HDWD HARDWOOD HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING-VENTILATION-AIR CONDITIONING ID INSIDE DIAMETER IN INCHES INSUL/INS INSULATION, INSULATED INT INTERIOR JAN JANITOR JST JOIST JT JOINT KIT KITCHEN K.D. KNOCKDOWN LAB LABORATORY LAM LAMINATED LAV LAVATORY LF LIGHT FIXTURE LT LIGHT LSD LIQUID SOAP DISPENSER MACH MACHINE MAX MAXIMUM MECH MECHANICAL MED MEDICINE MEMB MEMBRANE MET METAL MFR MANUFACTURER MGR MANAGER M.H. MANHOLE MIC. OV. MICROWAVE OVEN MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS M.O. MASONRY OPENING M.R. MOISTURE RESISTANT M.R.G.B. MOISTURE RESISTANT GYPSUM BOARD MTD MOUNTED MTL MATERIAL N NORTH N.I.C. NOT IN CONTACT NO.(#) NUMBER NOM. NOMINAL N.T.S. NOT TO SCALE O.A. OVERALL OC/oc ON CENTER O.C.E.W. ON CENTER EACH WAY OD OUTSIDE DIAMETER OFC or OFF OFFICE OF/CI OWNER FURNISHED/ CONTR INSTALLED OF/OI OWNER FURNISHED/ OWNER INSTALLED O.H. OPPOSITE HAND OPER OPERABLE OPNG OPENING OPP OPPOSITE OSB ORIENTED STRAND BOARD O.T.O. OUT TO OUTSIDE PC PORTLAND CEMENT PH PHONE (TELEPHONE) PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD PPT PRESERVATIVE PRESSURE TREATED PR PAIR PREP PREPARATION PT PAINT P.T.D. PAPER TOWEL DISPENSER PTN PARTITION P.T.D/R. COMBINATION PAPER TOWEL DISPENSER/ RECEPTACLE Q.T. QUARRY TILE R or RAD RADIUS RCP REFLECTED CEILING PLAN RD ROOF DRAIN REFER or REF REFERENCE REC'P RECEPTION REFR REFRIDGERATOR REINF REINFORCED RESIL RESILIENT RESIST RESISTANT REQ REQUIRED RET RETAINING REV REVISION R.F.S. ROOM FINISH SCHEDULE R.J. RUSTICATION JOINT RM. ROOM RO ROUGH OPENING RTU ROOF TOP UNIT (HVAC) RWC RAIN WATER CONDUCTOR S SOUTH SCHED/SCH SCHEDULE SCWD SOLID CORE WOOD SD SOAP DISPENSER SECT SECTION SEC'Y SECRETARY SH SHELF SHWR SHOWER SHT SHEET SHTH'G SHEATHING SIM SIMILAR S.N.D. SANITARY NAPKIN DISPENSER S.N.R. SANITARY NAPKIN RECEPTACLE SQ SQUARE S.S. STAINLESS STEEL S.SK. SERVICE SINK STA STATION STD STANDARD STL STEEL STN STAIN STOR STORAGE STR STRUCTURAL SUSP SUSPEND(ED) S&V STAIN & VARNISH SYM SYMMETRICAL T TREAD T.B. TOWEL BAR T.O.C. TOP OF CURB T/S TOILET/SHOWER TEL TELEPHONE TEMP TEMPERED/ TEMPORARY TER TERRAZZO TG TOP OF GRATE T&G TOUNGE AND GROOVE THK THICK(NESS) TLWC TOP OF LIGHTWEIGHT CONCRETE T.O. TOP OF T.O.M. TOP OF MASONRY T.O.S. TOP OF STEEL T.O.W./T.W. TOP OF WALL T.P. TOP OF PAVEMENT T.P.H. TOILET PAPER HOLDER TV TELEVISION TYP TYPICAL UL UNDERWRITERS LABORATORIES U.N.O. UNLESS NOTED OTHERWISE UR URINAL VERT VERTICAL VEST VESTIBULE VCT VINYL COMPOSITION TILE VWC VINYL WALL COVERING W WEST W/ WITH W.C. WATER CLOSET WD WOOD W/O WITHOUT WSCT WT WEIGHT MATERIALS LEGEND EARTH BRICK CMU CONCRETE STEEL GRAVEL RIGID INSULATION BATT INSULATION GROUT, MORTAR OR SAND PLYWOOD ROUGH WOOD CONTINUOUS ROUGH WOOD, NON-CONTINUOUS SYMBOLS LEGEND NOTE: CONTACT ARCHITECT PRIOR TO BIDDING TO CLARIFY ALL ABBREVIATIONS, MATERIAL INDICATIONS AND SYMBOLS SHOWN ON DRAWINGS BUT NOT INDICATED ON THIS SHEET. THE FOLLOWING SYMBOLS APPLY TO ALL ARCHITECTURAL SHEETS BUT NOT NECESSARILY TO OTHER DISCIPLINES SHEETS. WALL SECTION NORTH 1 A101 SIM 1 A101 SIM A101 1 SIM A101 Name Elevation 1i 1t 1 A101 SIM / SECTION NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER BUILDING SECTION DETAIL NUMBER SHEET NUMBER DETAIL REFERENCE DETAIL NUMBER SHEET NUMBER BUILDING ELEVATION A101 1 Ref 1 Ref 1 Ref 1 Ref INTERIOR ELEVATION 1 Ref 1 Ref 1 Ref 1 Ref DETAIL NUMBER SHEET NUMBER MILLWORK SECTION DETAIL NUMBER SHEET NUMBER REFERENCE, DATUM OR LEVEL NORTH REFERENCE ARROW POINTS TRUE NORTH CENTER LINE WINDOW TYPE PARTITION TYPE REVISION REFERENCE 1 REFERENCE TO DIMENSION POINT 9' - 10" FACE TO FACE OF STUD FACE TO FACE OF MAS CL COLUMN TO FACE MAS OR STUD OR CL COLUMN TO CL COLUMN PROJECT ALTERNATES: ALL ALTERNATES ACCEPTED ALTERNATE #1 (FIELD HOUSE): ALTERNATE #1 - DEDUCT ALTERNATE CONSISTS OF ALL MATERIALS AND LABOR NECESSARY TO CONSTRUCT: 2) 8'x78' BREEZEWAY ON NORTH SIDE OF BUILDING 3) FIVE MASONRY COLUMNS 4) 8'x115' TPO ROOFING SYSTEM 5) 8'x30' STANDING SEAM METAL ROOF ALTERNATE #2 (STEM BUILDING): ALTERNATE #2 - DEDUCT ALTERNATE CONSISTS OF ALL MATERIALS AND LABOR NECESSARY TO CONSTRUCT: 1) NORTH VESTIBULE ALTERNATE #3 (STEM BUILDING): ALTERNATE #3 - DEDUCT ALTERNATE CONSISTS OF ALL MATERIALS AND LABOR NECESSARY TO CONSTRUCT: 1) SOUTH VESTIBULE SHEET NO.: SHEET TITLE: PROJECT NO.: DATE: CHECKED BY: PROJ. MANAGER: DRAWN BY: BWEEKS BWEEKS PARTNERSHIP ARCHITECTS IN SEAL: ARCHITECTS INTERIOR DESIGNERS PLANNERS 3220 MARSHALL AVENUE NORMAN, OK 73072 TEL: 405.360.1300 FAX: 405.360.1431 KEYPLAN: JHOWARD CORDELL PUBLIC SCHOOLS 2014 BOND - FIELD HOUSE 606 E. THIRD STREET, CORDELL, OK 73632 1416 TF-000 MAY 11, 2015 COVER SHEET MECHANICAL MF-001 MECHANICAL TITLE AND SCHEDULES MF-101 MECHANICAL PLAN - 1ST FLOOR MF-201 MECHANICAL PLAN - ROOF MF-501 MECHANICAL DETAILS ELECTRICAL EF-001 ELECTRICAL TITLE SHEET AND RISER EF-101 ELECTRICAL LIGHTING PLAN EF-102 ELEC. POWER & SYSTEMS PLAN EF-601 ELECTRICAL SCHEDULES PLUMBING PF-001 PLUMBING COVER SHEET PF-100 OVERALL PLUMBING PLANS PF-101 BELOW GRADE PLUMBING PLAN - LOCKER ROOMS PF-102 BELOW GRADE PLUMBING PLAN - CONCESSIONS PF-103 ABOVE GRADE PLUMBING PLAN - LOCKER ROOMS PF-104 ABOVE GRADE PLUMBING PLAN - CONCESSIONS PF-111 OVERALL PLUMBING ROOF PLAN PF-201 SANITARY AND STORM PLUMBING ISOMETRIC PF-202 DOMESTIC WATER PLUMBING ISOMETRIC PF-301 PLUMBING DETAILS GENERAL TF-000 COVER SHEET LIFE SAFETY LSF-100 LIFE SAFETY AND CODE INFORMATION LSF-101 LIFE SAFETY PLAN AND CODE ANALYSIS LSF-102 LIFE SAFETY PLAN AND CODE ANALYSIS CIVIL CF-100 GENERAL NOTES - FIELD HOUSE CF-200 SURVEY - FIELD HOUSE CF-300 DEMOLITION & EROSION CONTROL - FIELD HOUSE CF-400 SITE PLAN - FIELD HOUSE CF-500 GRADING PLAN - FIELD HOUSE CF-600 UTILITY PLAN - FIELD HOUSE CF-700 DETAILS - FIELD HOUSE CF-701 DETAILS - FIELD HOUSE STRUCTURAL SF-000 GENERAL NOTES SF-001 GENERAL DETAILS SF-100 FIELD HOUSE - FOUNDATION PLAN SF-100A FIELD HOUSE - FOUNDATION PLAN ALT #1 SF-101 FIELD HOUSE - ROOF FRAMING PLAN SF-101A FIELD HOUSE ROOF FRAMING PLAN - ALT #1 SF-200 FOUNDATION DETAILS SF-300 FRAMING DETAILS SF-301 FRAMING DETAILS SF-302 FRAMING DETAILS SF-400 TRUSS DETAILS ARCHITECTURAL A-001 ARCHITECTURAL SITE PLAN AF-002 FIELD HOUSE SITE PLAN A-003 SITE DETAILS AF-100 FIELD HOUSE - OVERALL PLAN AF-101 FIELD HOUSE - ENLARGED PLAN AF-102 FIELD HOUSE - ENLARGED PLAN AF-110 ROOF PLAN AF-200 BUILDING ELEVATIONS AF-300 BUILDING SECTIONS AF-310 WALL SECTIONS AF-311 WALL SECTIONS AF-312 WALL SECTIONS AF-400 PARTITION SCHEDULE AF-500 PLAN DETAILS AF-510 SECTION DETAILS AF-511 SECTION DETAILS AF-600 INTERIOR ELEVATIONS AF-610 MILLWORK DETAILS AF-611 MILLWORK DETAILS AF-700 REFLECTED CEILING PLAN AF-800 FINISH FLOOR PLAN AND SIGNAGE PLAN AF-900 ROOM AND DOOR SCHEDULE AF-910 FRAMED OPENING DETAILS FIELD HOUSE CORDELL PUBLIC SCHOOLS - 2014 BOND 606 E. THIRD STREET, CORDELL, OK 73632 CONSULTANTS CIVIL Wallace Engineering 120 East Sheridan, Suite 104 Oklahoma City, OK 73104 Phone: 405-236-5858 Fax: 405-236-2058 Contact: Darren Burns, Principal STRUCTURAL Wallace Engineering 120 East Sheridan, Suite 104 Oklahoma City, OK 73104 Phone: 405-236-5858 Fax: 405-236-2058 Contact: Darren Burns, Principal MECHANICAL, ENGINEERING & PLUMBING MEP Associates, LLC 2600 Van Buren St. Suite 2604 Norman, OK 73072 Phone: 405-364-9926 Fax: 405-364-9936 Contact: Art Lantagne, Operations Manager VICINITY MAP ARCHITECTURAL STANDARDS ARCHITECTURAL Architects In Partnership 3220 Marshall Avenue Norman, OK 73072 Phone: 405-360-1300 Fax: 405-360-1431 Contact: James Howard, Project Architect Brian Weeks, Project Manager SHEET INDEX STEM BUILDING FIELD HOUSE SCHOOL CAMPUS CORDELL REVISIONS REV DATE DESCRIPTION 1 06/03/2015 FIRE MARSHALL REVISIONS 1

Transcript of S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk...

Page 1: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

AB ANCHOR BOLTACOUS ACOUSTICALACT ACOUSTICAL CEILING TILEAD AREA DRAINADD'L ADDITIONALADJ ADJUSTABLEADMIN ADMINISTRATIONAEWC ACCESSIBLE EWCAFF ABOVE FINISHED FLOORALUM/AL ALUMINUMALT ALTERNATEANCIL ANCILLARYANOD/AN ANODIZEDAPPROX APPROXIMATE(LY)ARCH ARCHITECT(URAL)AWI ARCH'TL WOODWORK

INSTITUTEBD BOARDBFF BELOW FINISHED FLOORBLDG BUILDINGBLK BLOCKBLK'G BLOCKINGBM BEAMB.O BOTTOM OFBEARING BRGBRK BRICKB.S. BOTH SIDESCAB CABINETSCF/CI CONTRACTOR FINISHED,

CONTRACTOR INSTALLEDCFMF COLD FORMED METAL

FRAMINGCL CENTERLINECLR CLEARCJ CONTROL JOINTCLG CEILINGCLO CLOSETCMU CONCRETE MASONRY

UNITCOL COLUMNCOMP COMPOSITE,

COMPOSITIONCONC CONCRETECONF CONFERENCECONST CONSTRUCTIONCONT CONTINUOUSCORR CORRIDORCPT CARPETCR COLD ROLLEDCRS COURSECT CERAMIC TILECTR CENTERCTSK COUNTERSINKCU.FT. CUBIC FOOTCU.YD. CUBIC YARDDBL DOUBLEDEG DEGREEDEPT DEPARTMENTDF DRINKING FOUNTAINDET DETAILDIA DIAMETERDIM/DIM'S DIMENSION(S)DISP DISPENSERDIV DIVISIONDN DOWNDR DOORDWR DRAWER

LIST OF ABBREVIATIONSDWG/DWG'S DRAWING/DRAWINGSE EASTEA EACHEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRICALELEV ELEVATOREMER EMERGENCYENCL ENCLOSUREENGR ENGINEEREQ EQUALEQUIP EQUIPMENTEWC ELECTRIC WATER

COOLEREXG/ EXIST EXISTINGEXP EXPANSIONEXPO EXPOSEDEXT EXTERIORFA FIRE ALARMFCU FAN COIL UNITFD FLOOR DRAINFDN FOUNDATIONFF FINISHED FLOORFE FIRE EXTINGUISHERFEB FIRE EXTINGUISHER

BRACKETFEC FIRE EXTINGUISHER

CABINETFIN FINISHFLEX FLEXIBLEFLR FLOORFLASH or FLG FLASHINGFR FIRE RATEDFRM FRAMEFRT FIRE RETARDANT

TREATEDFT FOOT or FEETFTG FOOTINGFURN FURNISHEDFURR'G FURRINGFV FIELD VERIFYGA GAUGEGALV GALVANIZEDGB GRAB BARGEN GENERALGI GALVANIZED IRONGL GLASSGLAZ GLAZINGGND ELECTRICAL GROUNDGR GRADEGYP GYPSUMHC HOLLOW CORE or

HANDICAP ACCESSIBLEHDW HARDWAREHDWD HARDWOODHM HOLLOW METALHORIZ HORIZONTALHR HOURHT HEIGHTHVAC HEATING-VENTILATION-AIR

CONDITIONINGID INSIDE DIAMETERIN INCHESINSUL/INS INSULATION, INSULATEDINT INTERIORJAN JANITORJST JOIST

JT JOINTKIT KITCHENK.D. KNOCKDOWNLAB LABORATORYLAM LAMINATEDLAV LAVATORYLF LIGHT FIXTURELT LIGHTLSD LIQUID SOAP DISPENSERMACH MACHINEMAX MAXIMUMMECH MECHANICALMED MEDICINEMEMB MEMBRANEMET METALMFR MANUFACTURERMGR MANAGERM.H. MANHOLEMIC. OV. MICROWAVE OVENMIN MINIMUMMIR MIRRORMISC MISCELLANEOUSM.O. MASONRY OPENINGM.R. MOISTURE RESISTANTM.R.G.B. MOISTURE RESISTANT

GYPSUM BOARDMTD MOUNTEDMTL MATERIALN NORTHN.I.C. NOT IN CONTACTNO.(#) NUMBERNOM. NOMINALN.T.S. NOT TO SCALEO.A. OVERALLOC/oc ON CENTERO.C.E.W. ON CENTER EACH WAYOD OUTSIDE DIAMETEROFC or OFF OFFICEOF/CI OWNER

FURNISHED/CONTR INSTALLED

OF/OI OWNER FURNISHED/OWNER INSTALLED

O.H. OPPOSITE HANDOPER OPERABLEOPNG OPENINGOPP OPPOSITEOSB ORIENTED STRAND BOARDO.T.O. OUT TO OUTSIDEPC PORTLAND CEMENTPH PHONE (TELEPHONE)PL PLATEPLAM PLASTIC LAMINATEPLAS PLASTERPLYWD PLYWOODPPT PRESERVATIVEPRESSURE TREATEDPR PAIRPREP PREPARATIONPT PAINTP.T.D. PAPER TOWEL DISPENSERPTN PARTITIONP.T.D/R. COMBINATION PAPER

TOWEL DISPENSER/ RECEPTACLE

Q.T. QUARRY TILE

R or RAD RADIUSRCP REFLECTED CEILING PLANRD ROOF DRAINREFER or REF REFERENCEREC'P RECEPTIONREFR REFRIDGERATORREINF REINFORCEDRESIL RESILIENTRESIST RESISTANTREQ REQUIREDRET RETAININGREV REVISIONR.F.S. ROOM FINISH SCHEDULER.J. RUSTICATION JOINTRM. ROOMRO ROUGH OPENINGRTU ROOF TOP UNIT (HVAC)RWC RAIN WATER CONDUCTORS SOUTHSCHED/SCH SCHEDULESCWD SOLID CORE WOODSD SOAP DISPENSERSECT SECTIONSEC'Y SECRETARYSH SHELFSHWR SHOWERSHT SHEETSHTH'G SHEATHINGSIM SIMILARS.N.D. SANITARY NAPKIN

DISPENSERS.N.R. SANITARY NAPKIN

RECEPTACLESQ SQUARES.S. STAINLESS STEELS.SK. SERVICE SINKSTA STATIONSTD STANDARDSTL STEELSTN STAINSTOR STORAGESTR STRUCTURALSUSP SUSPEND(ED)S&V STAIN & VARNISHSYM SYMMETRICALT TREADT.B. TOWEL BART.O.C. TOP OF CURBT/S TOILET/SHOWERTEL TELEPHONETEMP TEMPERED/ TEMPORARYTER TERRAZZOTG TOP OF GRATET&G TOUNGE AND GROOVETHK THICK(NESS)TLWC TOP OF LIGHTWEIGHT

CONCRETET.O. TOP OFT.O.M. TOP OF MASONRYT.O.S. TOP OF STEELT.O.W./T.W. TOP OF WALLT.P. TOP OF PAVEMENTT.P.H. TOILET PAPER HOLDERTV TELEVISIONTYP TYPICAL

UL UNDERWRITERS LABORATORIES

U.N.O. UNLESS NOTED OTHERWISE

UR URINALVERT VERTICALVEST VESTIBULEVCT VINYL COMPOSITION TILEVWC VINYL WALL COVERINGW WESTW/ WITHW.C. WATER CLOSETWD WOODW/O WITHOUTWSCTWT WEIGHT

MATERIALS LEGEND

EARTH

BRICK

CMU

CONCRETE

STEEL

GRAVEL

RIGID INSULATION

BATT INSULATION

GROUT, MORTAROR SAND

PLYWOOD

ROUGH WOODCONTINUOUS

ROUGH WOOD,NON-CONTINUOUS

SYMBOLS LEGEND

NOTE: CONTACT ARCHITECT PRIOR TO BIDDING TO CLARIFY ALL ABBREVIATIONS, MATERIAL INDICATIONS AND SYMBOLS SHOWN ON DRAWINGS BUT NOT INDICATED ON THIS SHEET.

THE FOLLOWING SYMBOLS APPLY TO ALL ARCHITECTURAL SHEETS BUT NOTNECESSARILY TO OTHER DISCIPLINES SHEETS.

WALL SECTION

NORTH

1A101

SIM

1A101

SIM

A1011

SIM

A101

NameElevation

1i

1t

1 A101 SIM/

SECTION NUMBERSHEET NUMBER

SECTION NUMBERSHEET NUMBER

BUILDING SECTION

DETAIL NUMBERSHEET NUMBER

DETAIL REFERENCE

DETAIL NUMBER

SHEET NUMBER

BUILDING ELEVATION

A101

1 Ref

1

Ref

1 Ref

1

Ref

INTERIOR ELEVATION

1 Ref

1

Ref

1 Ref

1R

ef

DETAIL NUMBER

SHEET NUMBER

MILLWORK SECTION

DETAIL NUMBERSHEET NUMBER

REFERENCE, DATUM OR LEVEL

NORTH REFERENCE ARROW POINTSTRUE NORTH

CENTER LINE

WINDOW TYPE

PARTITION TYPE

REVISION REFERENCE

1

REFERENCE TO DIMENSION POINT

9' - 10"

FACE TO FACE OF STUDFACE TO FACE OF MAS

CL COLUMN TO FACE MAS OR STUDOR CL COLUMN TO CL COLUMN

PROJECT ALTERNATES: ALL ALTERNATES ACCEPTED

ALTERNATE #1 (FIELD HOUSE):ALTERNATE #1 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TOCONSTRUCT:2) 8'x78' BREEZEWAY ON NORTH SIDE OF BUILDING3) FIVE MASONRY COLUMNS4) 8'x115' TPO ROOFING SYSTEM5) 8'x30' STANDING SEAM METAL ROOF

ALTERNATE #2 (STEM BUILDING):ALTERNATE #2 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TOCONSTRUCT:1) NORTH VESTIBULE

ALTERNATE #3 (STEM BUILDING):ALTERNATE #3 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TOCONSTRUCT:1) SOUTH VESTIBULE

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:BWEEKS

BWEEKS

PARTNERSHIP

ARCHITECTSIN

SEAL:

ARCHITECTSINTERIOR DESIGNERSPLANNERS

3220 MARSHALL AVENUENORMAN, OK 73072TEL: 405.360.1300FAX: 405.360.1431

KEYPLAN:

JHOWARD

CO

RD

ELL

PUB

LIC

SC

HO

OLS

2014

BO

ND

- FI

ELD

HO

USE

606

E. T

HIR

D S

TREE

T, C

OR

DEL

L, O

K 73

632

1416

TF-000

MAY 11, 2015

COVER SHEET

MECHANICALMF-001 MECHANICAL TITLE AND SCHEDULESMF-101 MECHANICAL PLAN - 1ST FLOORMF-201 MECHANICAL PLAN - ROOFMF-501 MECHANICAL DETAILS

ELECTRICALEF-001 ELECTRICAL TITLE SHEET AND RISEREF-101 ELECTRICAL LIGHTING PLANEF-102 ELEC. POWER & SYSTEMS PLANEF-601 ELECTRICAL SCHEDULES

PLUMBINGPF-001 PLUMBING COVER SHEETPF-100 OVERALL PLUMBING PLANSPF-101 BELOW GRADE PLUMBING PLAN - LOCKER ROOMSPF-102 BELOW GRADE PLUMBING PLAN - CONCESSIONSPF-103 ABOVE GRADE PLUMBING PLAN - LOCKER ROOMSPF-104 ABOVE GRADE PLUMBING PLAN - CONCESSIONSPF-111 OVERALL PLUMBING ROOF PLANPF-201 SANITARY AND STORM PLUMBING ISOMETRICPF-202 DOMESTIC WATER PLUMBING ISOMETRICPF-301 PLUMBING DETAILS

GENERALTF-000 COVER SHEET

LIFE SAFETYLSF-100 LIFE SAFETY AND CODE INFORMATIONLSF-101 LIFE SAFETY PLAN AND CODE ANALYSISLSF-102 LIFE SAFETY PLAN AND CODE ANALYSIS

CIVILCF-100 GENERAL NOTES - FIELD HOUSECF-200 SURVEY - FIELD HOUSECF-300 DEMOLITION & EROSION CONTROL - FIELD HOUSECF-400 SITE PLAN - FIELD HOUSECF-500 GRADING PLAN - FIELD HOUSECF-600 UTILITY PLAN - FIELD HOUSECF-700 DETAILS - FIELD HOUSECF-701 DETAILS - FIELD HOUSE

STRUCTURALSF-000 GENERAL NOTESSF-001 GENERAL DETAILSSF-100 FIELD HOUSE - FOUNDATION PLANSF-100A FIELD HOUSE - FOUNDATION PLAN ALT #1SF-101 FIELD HOUSE - ROOF FRAMING PLANSF-101A FIELD HOUSE ROOF FRAMING PLAN - ALT #1SF-200 FOUNDATION DETAILSSF-300 FRAMING DETAILSSF-301 FRAMING DETAILSSF-302 FRAMING DETAILSSF-400 TRUSS DETAILS

ARCHITECTURALA-001 ARCHITECTURAL SITE PLANAF-002 FIELD HOUSE SITE PLANA-003 SITE DETAILSAF-100 FIELD HOUSE - OVERALL PLANAF-101 FIELD HOUSE - ENLARGED PLANAF-102 FIELD HOUSE - ENLARGED PLANAF-110 ROOF PLANAF-200 BUILDING ELEVATIONSAF-300 BUILDING SECTIONSAF-310 WALL SECTIONSAF-311 WALL SECTIONSAF-312 WALL SECTIONSAF-400 PARTITION SCHEDULEAF-500 PLAN DETAILSAF-510 SECTION DETAILSAF-511 SECTION DETAILSAF-600 INTERIOR ELEVATIONSAF-610 MILLWORK DETAILSAF-611 MILLWORK DETAILSAF-700 REFLECTED CEILING PLANAF-800 FINISH FLOOR PLAN AND SIGNAGE PLANAF-900 ROOM AND DOOR SCHEDULEAF-910 FRAMED OPENING DETAILS

FIELD HOUSECORDELL PUBLIC SCHOOLS - 2014 BOND

606 E. THIRD STREET, CORDELL, OK 73632

CONSULTANTS

CIVIL

Wallace Engineering120 East Sheridan, Suite 104Oklahoma City, OK 73104Phone: 405-236-5858Fax: 405-236-2058Contact: Darren Burns, Principal

STRUCTURAL

Wallace Engineering120 East Sheridan, Suite 104Oklahoma City, OK 73104Phone: 405-236-5858Fax: 405-236-2058Contact: Darren Burns, Principal

MECHANICAL, ENGINEERING & PLUMBING

MEP Associates, LLC2600 Van Buren St. Suite 2604Norman, OK 73072Phone: 405-364-9926Fax: 405-364-9936Contact: Art Lantagne, Operations Manager

VICINITY MAPARCHITECTURAL STANDARDSARCHITECTURAL

Architects In Partnership3220 Marshall AvenueNorman, OK 73072Phone: 405-360-1300Fax: 405-360-1431Contact: James Howard, Project Architect

Brian Weeks, Project Manager

SHEET INDEX

STEM BUILDING

FIELD HOUSE

SCHOOLCAMPUS

CORDELL

REVISIONSREV DATE DESCRIPTION

1 06/03/2015 FIREMARSHALLREVISIONS

1

113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
ANYTOWN FIELD HOUSE
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, Ok. 00000
Page 2: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

BUILDING CODE INFORMATION

LIFE SAFETY AND FIRE PROTECTION CODE COMPLIANCE APPROACH NARATIVE

GENERAL PROJECT INFORMATION

OCCUPANCY LOAD, MEANS OF EGRESS AND PASSIVE FIRE PROTECTION FEATURES

INTERIOR FINISHES (IBC CHAPTER 8)

PLUMBING SYSTEMS FEATURES

PLUMBING SYSTEMS (IBC CHAPTER 29)

PROJECT NAME

PROJECT LOCATION

CORDELL PUBLIC SCHOOLS - NEW FIELD HOUSE AND STEM CLASSROOM BUILDINGS

606 E. THIRD STREE, CORDELL, OKLAHOMA 73632

PROJECT CONSTRUCTION PURPOSE NEW CONSTRUCTION - FIELD HOUSE AND CLASSROOM BUILDING

BUILDING OWNER BRAD OVERTON, SUPERINTENDENT, CORDELL PUBLIC SCHOOLS, PH: 580-832-3420

AUTHORITY HAVING JURISDICTION OKLAHOMA STATE FIRE MARSHAL'S OFFICE

PROJECT DESCRIPTION - SUMMARY

CLASSROOM BUILDING - NEW CLASSROOM BUILDING (9,389 SQ. FT.) CONSISTING OF FIVE CLASSROOMS, TWO SCIENCE LABORATORIES, RESTROOMS AND A TEACHER'S BREAKROOM. HALF OFTHE BUILDING (4,421 SQ. FT.) IS BEING CONSTRUCTED AS A SAFE ROOM WITH REINFORCED CMU WALLS AND CONCRETE LID. THE REMAINING PORTIONS OF THE BUILDING WILL BE STEELSTRUCTURE AND METAL STUD FRAMING. EXTERIOR MATERIALS WILL CONSIST OF COMMON BRICK, EIFS AND STOREFRONT GLAZING. BUILDING IS SPRINKLERED.

FIELD HOUSE BUILDING - NEW FIELD HOUSE BUILDING (7,729 SQ. FT.) CONSISTING OF TWO LOCKERROOMS/SHOWERS, COACHES OFFICE, WEIGHT ROOM , TICKET BOOTH, CONCESSIONS ANDRESTROOMS FOR THE SPORTS ASSEMBLY BLEACHERS. THE FIELD HOUSE IS BEING CONSTRUCTED WITH STEEL STRUCTURE AND CMU LOAD BEARING WALLS. EXTERIOR MATERIALS WILLCONSIST OF SPLIT FACE CMU, COMMON BRICK AND EIFS. BUILDING IS NOT SPRINKLERED.

APPLICABLE DESIGN CRITERIA (APPLICABLE CODES ARE CHECKED)NAME EDITION

INTERNATIONAL BUILDING CODE (IBC) 2009

NFPA 1: FIRE CODE 2012

NFPA 10: STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2012

NFPA 13: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2013

NFPA 24: STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES

NFPA 30: FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE

NFPA 33: STANDARD FOR SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE MATERIALS

NFPA 70: NATIONAL ELECTRIC CODE

NFPA 72: NATIONAL FIRE ALARM AND SIGNALING CODE

2013

2012

2011

2011

2013

NFPA 220: STANDARD ON TYPE OF BUILDING CONSTRUCTION 2012

UNIFIED FACILITIES CRITERIA (UFC) 1-200-01: GENERAL BUILDING REQUIREMENTS 16 AUG 2010 WITH CHANGE 2, 28 NOV 2011

UNIFIED FACILITIES CRITERIA (UFC) 3-600-01: FIRE PROTECTION ENGINEERING FOR FACILITIES 26 SEPT 2006 WITH CHANGE 3, 1 MAR 2013

UNIFIED FACILITIES CRITERIA (UFC) 4-010-01: DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS 8 OCT 2003 INCLUDING CHANGE 1, 22 JAN 2007

UNIFIED FACILITIES CRITERIA (UFC) 4-021-01: DESIGN AND O&M: MASS NOTIFICATION SYSTEMS 9 APR 2008 WITH CHANGE 1, JAN 2010

BUILDING OCCUPANCY, CONSTRUCTION AND SEPARATION INFORMATION

BUILDING NAME AREANFPA 101 CLASSIFICATION

7,729 SQ. FT. GROSSNEW FIELD HOUSE NEW EDUCATIONAL OCCUPANCIES (CHAPTER 14)

IBC CLASSIFICATION

EDUCATIONAL E (SECTION 305)

GENERAL BUILDING HEIGHTS AND AREA (IBC CHAPTER 5)ALLOWABLE BUILDING HEIGHTS AND AREAS (IBC, TABLE 503)

GROUP

USE AND OCCUPANCY CLASSIFICATION (IBC CHAPTER 3)

E

HEIGHT (ft)

TYPE II B

STORIES

AREA

2

14,500 SF

55

AS-DESIGNED BUILDING HEIGHTS AND AREAS

GROUP

E

HEIGHT (ft)

TYPE II B

STORIES

AREA

1

7,729 SF

25

BUILDING AREA MODIFICATIONS (IBC, SECTION 506)

THE BUILDING AREAS LIMITED BY TABLE 503 SHALL BE PERMITTED TO BE INCREASED DUE TO FRONTAGE (If) AND AUTOMATIC SPRINKLER SYSTEM PROTECTION (I) INACCORDANCE WITH THE FOLLOWING: Aa = At + [At x If / 100] + [At x Is / 100]

BUILDING AREA MODIFICATIONS ARE NOT REQUIRED OR APPLICABLE SINCE THE PROJECT SCOPE OF WORK COMPLIES WITH THE ALLOWABLE BUILDING HEIGHT AND AREA FROMTABLE 503.

SECTION 506.1

REQUIRED SEPARATION OF OCCUPANCIES (IBC, SECTION 508)

SEPARATION OF OCCUPANCIES ARE NOT REQUIRED OR APPLICABLE SINCE THE PROJECT SCOPE OF WORK CONSISTS OF ONE OCCUPANCY TYPE.

SECTION 508.4

TYPES OF CONSTRUCTION (IBC CHAPTER 6)FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (IBC, TABLE 601)

INTERIOR BEARING WALLS

BUILDING ELEMENT

EXTERIOR BEARING WALLS

PRIMARY STRUCTURAL FRAME (SEE IBC SECTION 202)

FLOOR CONSTRUCTION AND SECONDARY MEMBERS

ROOF CONSTRUCTION AND SECONDARY MEMBERS

HOURLY RATING REQUIRED HOURLY RATING PROVIDED

0 0

0 4

0 4

0 0

0 1

METHOD OF ACHIEVING RATING

N/A

8" CMU BLOCK -SOLID FILL CELLS

8" CMU BLOCK - SOLID FILL CELLS

N/A

BUILT-UP ROOF ON METAL DECK ON STEEL JOISTS

INTERIOR NONBEARING WALLS

EXTERIOR NONBEARING WALLS 0 4

0 4

8" CMU BLOCK -SOLID FILL CELLS

8" CMU BLOCK - SOLID FILL CELLS

FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (IBC, TABLE 602)

FIRE SEPARATION DISTANCE = X (feet)

10 ≤ X ≤ 30

TYPE OF CONSTRUCTION OCCUPANCY GROUP

IIB E

FIRE RESISTANCE REQUIRED

0

FIRE RESISTANCE PROVIDED

4

FIRE AND SMOKE PROTECTION FEATURES (IBC CHAPTER 7)MAXIUMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION (IBC, TABLE 705.8)

FIRE SEPARATION DISTANCE (feet) DEGREE OF OPENING PROTECTION ALLOWABLE AREA

30 OR GREATER UNPROTECTED, NONSPRINKLERED NO LIMIT

FIRE WALLS (IBC, SECTION 706)

FIRE SEPARATION DISTANCE (feet) DEGREE OF OPENING PROTECTION ALLOWABLE AREA

30 OR GREATER UNPROTECTED, NONSPRINKLERED NO LIMIT

FIRE WALL FIRE-RESISTANCE RATINGS (IBC, TABLE 706.4)

GROUP FIRE RESISTANCE RATING (hours) CONTRUCTION NOTES

E 2 NO FIRE WALL REQUIRED FOR THIS PROJECT

FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS (IBC, TABLE 707.3.9)

GROUP FIRE RESISTANCE RATING (hours) CONTRUCTION NOTES

E 2 NO FIRE BARRIER REQUIRED FOR THIS PROJECT

SHAFT ENCLOSURES (IBC, SECTION 708; NFPA 101 8.6.5)

GROUP FIRE RESISTANCE RATING (hours) CONTRUCTION NOTES

E X NO SHAFT ENCLOSURES IN THIS PROJECT

INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY (IBC, TABLE 803.9)

GROUP

SPRINKLERED NONSPRINKLERED

EXITS

EDUCATIONAL E

CORRIDORS ROOMS EXITS CORRIDORS ROOMS

CLASS A CLASS B CLASS C

FIRE PROTECTION SYSTEMS (IBC CHAPTER 9)AUTOMATIC SPRINKLER SYSTEMS (IBC, SECTION 903)

GROUP

AUTOMATIC SPRINKLER SYSTEM NOT PROVIDED

EDUCATIONAL E

STATUS

PER SECTION 903.2.3, AN AUTOMATIC SPRINKLER SYSTEM IS NOT REQUIRED.

PORTABLE FIRE EXTINGUISHERS (IBC, SECTION 906)

ORDINARY (MODERATE) HAZARD OCCUPANCY

MIN. RATED SINGLE EXTINGUISHER

FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS (IBC, TABLE 906.3(1))

2-A

MAXIMUM FLOOR AREA PER UNIT OF A 1,500 SQ. FT.

MAXIMUM FLOOR AREA FOR EXTINGUISHER 11,250 SQ. FT.

MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER 75 FEET

8,090 SQ. FT. / 1,500 SQ. FT. = 6 EXTINGUISHERS MINIMUM

BUILDING AREA LESS THAN MAXIMUM FLOOR AREA

EXTINGUISHERS AS PROVIDED

FIRE ALARM AND DETECTION SYSTEMS (IBC, SECTION 907.2.3)

FIRE ALARM SYSTEM

GROUP EDUCATIONAL E

MANUAL REQUIRED

SMOKE DETECTION SYSTEM AUTOMATIC REQUIRED

OCCUPANCY NOTIFICATION SYSTEM AUTOMATIC REQUIRED

EXIT SIGNS - REQUIRED

MEANS OF EGRESS (IBC CHAPTER 10)OCCUPANCT LOAD CALCULATIONS (IBC TABLE 1004.1.1)

EGRESS WIDTH (IBC, SECTION 1005)

MINIMUM REQUIRED EGRESS WIDTH SHALL BE A TOTAL WIDTH OF MEANS OF EGRESS IN INCHES NOT LESS THAN THE TOTAL OCCUPANCT LOAD SERVED BY THE MEANSOF EGRESS MULTIPLIED BY 0.2 INCHES PER OCCUPANT.

OCCUPANCY OF 160 -> 160 * 0.2 = 32" MINIMUM EGRESS WIDTH

EXIT ACCESS TRAVEL DISTANCE (IBC, SECTION 1016, TABLE 1016.1)

EDUCATIONAL E

OCCUPANCY

COMMON PATH OF TRAVEL

COMPONENT

DEAD END CORRIDORS

TRAVEL TO EXIT

75

REQUIRED (FEET)

20

150

NFPA 101 14.2.5.3.2

SOURCE

IBC 1016.3

NFPA 101 14.2.6.2

67 FEET (WEIGHT ROOM NO. 111)

PROVIDED

0 FEET (NO DEAD END CORRIDORS IN EDUCATIONAL USE)

67 FEET (WEIGHT ROOM NO. 111)

ACCESSIBILITY FEATURES

ACCESSIBILITY (IBC CHAPTER 11)ACCESSIBLE PARKING SPACES (IBC, TABLE 1106.1)

GROUP

REQUIRED PROVIDED

BUILDING AREA

EDUCATIONAL E

SPACES

PARKING REQUIREMENTS

UP TO 12,000 SQ. FT. GLA 1 SPACE PER 200 SQ. FT. GLA

BUILDING AREA SPACES

7,729 SQ. FT. 39 REQUIRED

ACCESSIBILE REQUIRED ACCESSIBILE PROVIDED

TOTAL SPACES REQUIRED MINIMUM

26 TO 50 2

TOTAL SPACES SPACES

39 TOTAL 2

CLASSIFICATION

EDUCATIONAL E

OCCUPANCY

155

REQUIRED

WATER CLOSETS

MALE FEMALE

LAVATORIES

MALE FEMALE

BATHTUBSOR SHOWER

DRINKINGFOUNTAINS

OTHER

1 PER 50 (3 REQUIRED) 1 PER 50 (3 REQUIRED) - 1 PER 100 1 SERVICE SINK

CLASSIFICATION

EDUCATIONAL E

OCCUPANCY

EXISTING

WATER CLOSETS

MALE FEMALE

LAVATORIES

MALE FEMALE

BATHTUBSOR SHOWER

DRINKINGFOUNTAINS

OTHER

6 (4 + 2 URINALS) - - -6 2 2

CLASSIFICATION

EDUCATIONAL E

OCCUPANCY

155

PROVIDED

WATER CLOSETS

MALE FEMALE

LAVATORIES

MALE FEMALE

BATHTUBSOR SHOWER

DRINKINGFOUNTAINS

OTHER

4 (1 + 2 URINAL) - 2 (HI-LO) 1 SERVICE SINK3 4 3

TOTALS (W EXIST.) 2155 18 14 - 4 (HI-LO) 2 SERVICE SINK1326

OCCUPANCY LOAD

6,498 SQ. FT. NET 155

ESTIMATED PROJECT COST FIELD HOUSE - $1,816,791; STEM BUILDING - $2,067,025; TOTAL - $4,549,874

ALTERNATES - ALL ALTERNATES HAVE BEEN ACCEPTED

ALTERNATE #1 (FIELD HOUSE):ALTERNATE #1 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TO CONSTRUCT:2) 8'x78' BREEZEWAY ON NORTH SIDE OF BUILDING3) FIVE MASONRY COLUMNS4) 8'x115' TPO ROOFING SYSTEM5) 8'x30' STANDING SEAM METAL ROOF

ALTERNATE #2 (STEM BUILDING):ALTERNATE #2 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TO CONSTRUCT:1) NORTH VESTIBULE

ALTERNATE #3 (STEM BUILDING):ALTERNATE #3 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TO CONSTRUCT:1) SOUTH VESTIBULE

X

X

X

X

X

X

X

X

STATE CODE ADOPTION

INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2009X

INTERNATIONAL FIRE CODE (IFC) 2009X

INTERNATIONAL FUEL GAS CODE (IFGC) 2009X

INTERNATIONAL MECHANICAL CODE (IMC) 2009X

INTERNATIONAL PLUMBING CODE (IPC) 2009X

NATIONAL ELECTRIC CODE (NEC) 2011X

ADDITIONAL CODES

FIRE MARSHAL DIRECTIVES

FEMA 320: TAKING SHELTER FROM THE STORM, BUILDING A SAFE ROOM FOR YOUR HOME OR SMALL BUSINESS

FEMA 361: DESIGN AND CONSTRUCTION GUIDANCE FOR COMMUNITY SAFEROOMS

2008

2008

ICC 500: STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS 2008

SPECIAL REQUIREMENTS BASED ON USE AND OCCUPANCY (IBC CHAPTER 4)

MEANS OF EGRESS (IBC CHAPTER 10) - CONTINUED

MEANS OF EGRESS ILLUMINATION (IBC, SECTION 1006)

THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED.

EMERGENCY LIGHTING AUTOMATIC REQUIRED

EXIT SIGNS (IBC, SECTION 1011)

EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL.

EXIT SIGNS AUTOMATIC REQUIRED

ASSEMBLY - BLEACHERS (IBC, SECTION 1024; ICC-300)

• BLEACHERS ARE NOT IN THIS PROJECT AND WILL BE BY OWNER. BLEACHER DESIGN AND PERMIT TO BE SUBMITTED AT A LATER DATE.

- 2(1 PER 1000)

1 SERVICE SINKASSEMBLY A-5

(FOR 2000 EXISTINGAND NEW

BLEACHERS)

2000 13(1 PER 75 FOR THEFIRST 1,500 AND 1PER 120 FOR THE

REMAINDEREXCEEDING 1,500)

25(1 PER 40 FOR THEFIRST 1,520 AND 1PER 60 FOR THE

REMAINDEREXCEEDING 1,500)

5(1 PER 200)

7(1 PER 150)

ASSEMBLY A-5

(FOR 1000 EXISTINGBLEACHERS)

1000

8 (3 + 5 URINALS) -17 8 8ASSEMBLY A-5

(FOR 1000 EXISTINGBLEACHERS)

1000 2 (HI-LO) 1 SERVICE SINK

REQ'D TOTALS 2155 16 8 - 3 2 SERVICE SINK1025

PLUMBING SYSTEMS HAVE BEEN DESIGNED AND CALCULATED FOR THE FUTURE INSTALLATION OF ADDITIONAL BLEACHERS.

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:BWEEKS

BWEEKS

PARTNERSHIP

ARCHITECTSIN

SEAL:

ARCHITECTSINTERIOR DESIGNERSPLANNERS

3220 MARSHALL AVENUENORMAN, OK 73072TEL: 405.360.1300FAX: 405.360.1431

KEYPLAN:

JHOWARD

CO

RD

ELL

PUB

LIC

SC

HO

OLS

2014

BO

ND

- FI

ELD

HO

USE

606

E. T

HIR

D S

TREE

T, C

OR

DEL

L, O

K 73

632

1416

LSF-100

MAY 11, 2015

LIFE SAFETY ANDCODE

INFORMATION

OCCUPANCY SCHEDULE

ROOM NO. NAME Occupancy

OCCUPANCY AREAS

TABLE 1004.1.2 -MAXIMUM

FLOORALLOWANCES

Area Type

TABLE 1004.1.2- MAXIMUM

FLOORALLOWANCES

ROOM AREAS.F. PERPERSON

OCCUPANCYLOAD

CALCULATED

000 TICKET BOOTH E 49 SF 100 GROSS 1100 CORRIDOR E 231 SF 0 - 0101 VARSITY LOCKER ROOM E 706 SF 20 NET 35102 TOILETS E 263 SF 50 NET 5103 ELEC S-2 52 SF 0 - 0104 JUNIOR VARSITY LOCKER ROOM E 499 SF 20 NET 25105 TOILETS E 263 SF 50 NET 5106 JANITOR S-2 53 SF 0 - 0107 EQUIPMENT STORAGE S-2 245 SF 50 NET 5108 COACHES OFFICE E 744 SF 50 NET 15109 COACHES DRESSING E 119 SF 50 NET 2110 TAPE ROOM E 162 SF 50 NET 3111 WEIGHT ROOM E 1508 SF 50 NET 30200 CONCESSION E 365 SF 50 NET 7201 CONCESSION STORAGE S-2 146 SF 50 NET 2202 ELEC S-2 69 SF 0 - 0204 MEN E 372 SF 50 NET 7205 WOMEN E 578 SF 50 NET 12206 FAMILY RESTROOM E 73 SF 50 NET 1

Grand total 6498 SF 155

REVISIONSREV DATE DESCRIPTION

1 06/03/2015 FIREMARSHALLREVISIONS

1

1

1

1

1

113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
Page 3: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

S 90°00'00" E 870.00'

FF 1556.19

FF 1556.19

CO

RD

EL

L P

UB

LIC

S

CH

OO

LS

NE

W F

IE

LD

H

OU

SE

A

ND

S

TE

M C

LA

SS

RO

OM

B

UIL

DIN

GS

60

6 E

. T

HIR

D S

TR

EE

T, C

OR

DE

LL

, O

K 7

36

32

04/22/2015

1416

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:

ARCHITECTS

IN

SEAL:

3220 MARSHALL AVENUE

NORMAN, OK 73072

TEL: 405.360.1300

FAX: 405.360.1431

bweeks

bweeks

jhoward

REVISIONS

REV DATE DESCRIPTION

1 06/03/2015 FIRE

MARSHALL

REVISIONS

AF-002

FIELD HOUSE

SITE PLAN

NORTH

FIELD HOUSE SITE PLAN

SCALE: 1"=20'-0"

01

CL

OF

FIELD

EXISTING DUMPSTER

EXISTING

WEIGHT

ROOM

EXISTING

SHOP

BUILDING

EXISTING

GREEN

HOUSE

EXISTING

GYMNASIUM

NEW FIELD HOUSE

EXISTING

BAND

BUILDING

EXISTING

LOCKER

ROOMS

EXISTING

TICKET

BOOTH

NEW SPORTS TRACK

BY OWNER NIC

NEW SIDEWALK

REFER CIVIL

202'-10"254'-11" +/-

5'-0

"5

2'-0

"8

'-0

"

65

'-0

"4

5'-0

"5

'-5

"1

8'-0

"

5'-0" 136'-5" 5'-0" 58'-8" 204'-1" +/-

205'-1"

(8) 9' SPACES @ 72'-0"

11'-0" 5'-0" 11'-0" 11'-0" 5'-0" 11'-0" 45'-0"

(4) 9' SPACES @ 36'-0"

56'-2"

HCS HCS HCS HCS

B B B B B B B

FP

GLGL

EXISTING OPEN PARKING

LOT THIS AREA

EXISTING OPEN PARKING

LOT THIS AREA

NEW ASPHALT

REFER CIVIL

207'-0"

E 3RD STREET

24

6'-3

" +

/-

SYMBOL DESCRIPTION

GROUND LIGHT - REFER ELECTRICAL

HANDICAP PARKING SIGN - REFER 04/A-003

FLAG POLE - REFER 05/A-003

BOLLARD - REFER 06/A-003B

GL

FP

HCS

LANDSCAPING, TOP SOIL AND SOD BY OWNER

BOOK 24, PAGE 463

BOOK 24, PAGE 463, FILED JANUARY 17, 1914 AT 11:30AM, DEED TO THE

BOARD OF EDUCATION OF THE CITY OF NEW CORDELL OF THE STATE

OF OKLAHOMA AND COVERING A TRACT OF LAND BEGINNING AT THE

POINT 70 FEET SOUTH AND 400 FEET EAST OF THE CENTER OF

SECTION 34-10-17, SAID POINT OF BEGINNING BEING THE

INTERSECTION OF THE SOUTH LINE OF CANION STREET AND EAST

LINE OF MAGNOLIA AVENUE, THENCE SOUTH ALONG THE EAST LINE

OF MAGNOLIA AVENUE 1060 FEET TO THE NORTH LINE OF SPRING

STREET, THENCE EAST ALONG THE NORTH LINE OF SPRING STREET

870 FEET TO THE WEST LINE OF EAST AVENUE, THENCE NORTH

ALONG THE WEST LINE OF EAST AVENUE 1060 FEET TO THE SOUTH

LINE OF CANION STREET, THENCE WEST ALONG THE SOUTH LINE OF

CANION STREET 870 FEET TO THE POINT OF BEGINNING AND SAID

TRACT OF LAND CONTAINING 21.17 ACRES, MORE OR LESS.

CONSTRUCTION SIGN LOCATION

REFER 07/A-003

NEW

FIRE HYDRANT

FIRE HYDRANT LINE AND DISTANCE

286' HOSE DISTANCE

1

1

1

113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
Page 4: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

16

7

6

Gate

FH

6

Gate

FF 1546.66

FF 1556.19

FF 1556.19

FUTURE

CO

RD

EL

L P

UB

LIC

S

CH

OO

LS

NE

W F

IE

LD

H

OU

SE

A

ND

S

TE

M C

LA

SS

RO

OM

B

UIL

DIN

GS

60

6 E

. T

HIR

D S

TR

EE

T, C

OR

DE

LL

, O

K 7

36

32

04/22/2015

1416

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:

ARCHITECTS

IN

SEAL:

3220 MARSHALL AVENUE

NORMAN, OK 73072

TEL: 405.360.1300

FAX: 405.360.1431

DATEREV. DESCRIPTION

REVISIONS

bweeks

bweeks

jhoward

A-001

OVERALL

SITE PLAN

NORTH

ARCHITECTURAL SITE PLAN

SCALE: 1"=50'-0"

01

AF-002

01

AC-002

01

NEW RUNNING TRACK

EXISTING FOOTBALL FIELD

EXISTING STANDS

E 5TH STREET

E 3RD STREET

N. M

AG

NO

LIA

A

VE

NU

E

N. M

AS

SIN

GA

LE

D

RIV

E

N. M

AG

NO

LIA

A

VE

NU

E

N. M

AS

SIN

GA

LE

D

RIV

E

E 2ND STREET

EXISTING

WEIGHT

ROOM

EXISTING

SHOP

BUILDING

EXISTING

GREEN

HOUSE

EXISTING

GYMNASIUM

EXISTING

SCHOOL

BUILDING

EXISTING

BAND

BUILDING

EXISTING

LOCKER

ROOMS

NEW FIELD HOUSE

NEW STEM

CLASSROOM

BUILDING

CGMPCORRUGATED GALVENIZED METAL PIPE

STORM SEWER MANHOLE

GP (GUARD POST)

HANDICAP PARKING

WATER METER

WATER VALVE

RISER

TRAFFIC SIGNAL

SIGN

POWER POLE

TELEPHONE MANHOLE

STORM SEWER INLET

MH

TOP OF GRATE

RIGHT-OF-WAY

PROPERTY LINE

IRON ROD

TOP OF RIM

BUILDING LIMIT LINE

TG

B/L

TR

IR

R/W

IRON ROD (FOUND)

IRON ROD (SET)

CLEAN OUT

ELECTRIC MANHOLE

MAIL BOX

SANITARY SEWER MANHOLE

LIGHT POLE

GUY WIRE

GAS VALVE

FIRE HYDRANT

GAS METER

GV

LP

GW

GM

C.O.

FH

OVERHEAD ELECTRIC CABLE

REINFORCED CONCRETE PIPE

UNDERGROUND SANITARY SEWER

UNDERGROUND GAS

UNDERGROUND ELECTRIC CABLE

REINFORCED CONCRETE BOX

RCB

RCP

UNDERGROUND WATER

UNDERGROUND TELEPHONE CABLE

UNDERGROUND STORM SEWER

UGE

GAS

SS

ST

UGT

W

STOCKADE FENCE

BUSH

CHAINLINK FENCE

X X

BARBED WIRE FENCE

E

EM (ELECTRIC METER)

AV

AIR VALVE(BLOW-OFF VALVE)

ACCESS EASEMENT A/E

UTILITY EASEMENT U/E

DRAINAGE & UTILITY EASEMENT D & U/E

DRAINAGE EASEMENT D/E

ST

SS

P/L

OHE

WV

WM

SITE PLAN LEGEND

SITE DATA

SITE AREA

TOTAL BUILDING AREA

PARKING SPACES

ACCESSIBLE PARKING SPACES

TOTAL PARKING SPACES

21.17 ACRES

LEGAL DESCRIPTON

FIELD HOUSE

GENERAL NOTES

A. ALL CONCRETE CURB DIMENSIONS ARE TO FACE OF CURB.

A TRACT OF LAND BEGINNING AT THE POINT 730 FEET SOUTH AND 400 FEET EAST

OF THE CENTER OF SECTION 34-10-17, SAID POINT OF BEGINNING BEING THE

INTERSECTION OF THE SOUTH LINE OF CANION STREET AND EAST LINE OF

MAGNOLIA AVENUE, THENCE SOUTH ALONG THE EAST LINE OF MAGNOLIA

AVENUE 1060 FEET TO THE NORTH LINE OF SPRING STREET, THENCE EAST

ALONG THE NORTH LINE OF SPRING STREET 870 FEET TO THE WEST LINE OF

EAST AVENUE, THENCE NORTH ALONG THE WEST LINE OF EAST AVENUE 1060

FEET TO THE SOUTH LINE OF CANION STREET, THENCE WEST ALONG THE SOUTH

LINE OF CANION STREET 870 FEET TO THE POINT OF BEGINNING AND SAID TRACT

OF LAND CONTAINING 21.17 ACRES, MORE OR LESS.

STEM BUILDING

7,729 SQ. FT.

9,389 SQ. FT.

FIELD HOUSE

STEM BUILDING

39 SPACES

47 SPACES

FIELD HOUSE

STEM BUILDING

2 SPACES

2 SPACES

FIELD HOUSE

STEM BUILDING

41 TOTAL

49 SPACES

N. C

RID

ER

R

OA

D

E. MAIN STREET

NOT TO SCALE

SITE LOCATION

E. 14TH STREET

34

N. G

RA

NT

S

TE

ET

VICINITY MAP

SEC. 34

T-10-N

R-17-W

I.M.

ALL WORK PERFORMED AND MATERIALS SUPPLIED SHALL

CONFORM TO THE PLANS AND/OR PROJECT SPECIFICATIONS. ANY

WORK NOT COVERED SHALL CONFORM TO THE CITY'S STANDARD

SPECIFICATIONS FOR THE CONSTRUCTION OF PUBLIC

IMPROVEMENTS OR THE "STANDARD SPECIFICATIONS FOR

HIGHWAY CONSTRUCTION, OKLAHOMA DEPARTMENT OF

TRANSPORTATION", LATEST EDITION AND SUPPLIMENTALS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL

UTILITY COMPANIES AND GOVERNMENTAL AGENCIES WHO MIGHT

HAVE UTILITY LINES ON OR ABOUT THE PREMESIS, OR WHO MIGHT

BE AFFECTED BY THE CONSTRUCTION. THE CONTRACTOR SHALL

ALSO COORDINATE WITH THE UTILITY COMPANIES TO ENSURE

COMPLIANCE TO THE PROJECT SCHEDULE ESTABLISHED BY THE

GENERAL CONTRACTOR. THE CONTRACTOR SHALL MAKE EVERY

EFFORT TO PROTECT EXISTING UTILITY LINES AND SHALL REPAIR

ANY DAMAGES AT HIS OWN EXPENSE.

ALL SIGNS, PAVEMENT MARKINGS, AND OTHER TRAFFIC CONTROL

DEVICES SHALL CONFORM TO THE MANUAL OF UNIFORM TRAFFIC

CONTROL DEVICES, LATEST EDITION. ALL PAVEMENT STRIPING

SHALL BE FOUR (4) INCHES WIDE, UNLESS SHOWN OTHERWISE ON

THE PLANS.

THE CONTRACTOR SHALL PROVIDE A MEDIUM BROOM FINISH ON

ALL CONCRETE WALKS, RAMPS, AND PAVING SURFACES.

MAINTENANCE OF SEEDED AND SODDED AREAS SHALL INCLUDE

ALL NECESSARY FERTILIZATION AND WATERING UNTIL SUCH TIME

AS PROPER VEGITATION AND ROOT GROWTH IS ESTABLISHED.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTING AND

MAINTAINING BARRICADES AND OTHER TRAFFIC CONTROL

DEVICES AS NECESSARY AROUND THE PERIMIETER.

THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL

SIDEWALKS AND ACCESSIBLE RAMPS ARE IN COMPLIANCE WITH

THE ADAAG REGULATIONS. THE CONTRACTOR SHALL NOTIFY THE

ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DESIGN

INFORMATION AND ADAAG REGULATIONS PRIOR TO

CONSTRUCTION.

CONTRACTOR SHALL SATISFY HIMSELF AS TO EARTHWORK

QUANTITIES PRIOR TO BIDDING.

113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
Page 5: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

WD

REF

.

FEC A

FECB FECC

F1

F1

F7

F7

F2

F2

F3

F3

F4

F4

F5

F5

F6

F6

FCFC

FBFB

FDFD

F6.9

F6.9

F3.9

F3.9

F2.1

F2.1

=1508 SFE

WEIGHTROOM 111

3050 SF

=53 SFS-2

JANITOR 106

00 SF

=231 SFE

CORRIDOR 100

00 SF

=263 SFE

TOILETS 102

550 SF

=706 SFE

VARSITYLOCKERROOM 101

3520 SF

=263 SFE

TOILETS 105

550 SF

=245 SFS-2

EQUIPMENTSTORAGE 107

550 SF

=119 SFE

COACHESDRESSING 109

250 SF

ICE

=178 SFE

TAPEROOM 110

350 SF

=52 SFS-2

ELEC 103

00 SF

=744 SFE

COACHESOFFICE 108

1550 SF

EWC

100.172"

400.15"

106.136"

00.15"

101.136"

240.15"

104.136"

160.15"

107.136"

10.15"

109.136"

10.15"

110.136"

20.15"

103.136"

00.15"

111.236"

00.15"

101.236"

00.15"

111.336"

190.15"

104.336"

00.15"

FD

EGRESSPATH A

EGRESSPATH H

EGRESSPATH H

EGRESSPATH A

EGRESSPATH B

EGRESSPATH B

EGRESSPATH I

EGRESSPATH G

EGRESSPATH G

37'-0"

62'-0"

57'-0"

57'-0"

56'-0"

FAFA

ALTERNATE #1

EGRESSPATH C

EGRESSPATH C64'-0"

EGRESSPATH D60'-0"

EGRESSPATH D

EGRESSPATH J

28'-0"

EGRESSPATH J

EGRESSPATH I

EGRESSPATH E

EGRESSPATH E

57'-0"

EGRESSPATH F

EGRESSPATH F

31'-0"

ADA

ADA

ADA

ADA

ADA

ADA

3 HR RATEDDOOR & FRAME

3 HR RATEDDOOR &FRAME

3 HR RATEDDOOR &FRAME

3 HR RATEDDOOR & FRAME

EXIT DEVICE

EXIT DEVICE

EXIT DEVICE

EXIT DEVICE

EXIT DEVICE

36"108.1 11

0.15" 36"111.1 30

0.15"

/1 LSF-102

OCCUPANCY TYPEROOM NAME

SF PER PERSON

NAME ##B ### SF ### SF= ###

ROOM SFROOM NUMBER

OCCUPANCY LOAD

###36"

##0.15"

DOOR NUMBER

DOOR WIDTH

OCCUPANCY LOAD

REQ'D WIDTHPER OCCUPANT

DOOR TAG

ROOM TAG

LIFE SAFETY LEGEND

PARTITION KEY -REFER AC-400 PARTITIONSCHEDULE

1i

EGRESS PATH

FIRE EXTINGUISHER CABINETFEC

ADA ADA PUSH BUTTON DOOROPERATOR

RATED CORRIDOR -REINFORCED, FULLY GROUTEDCMU WALL - 4 HR RATED

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:BWEEKS

BWEEKS

PARTNERSHIP

ARCHITECTSIN

SEAL:

ARCHITECTSINTERIOR DESIGNERSPLANNERS

3220 MARSHALL AVENUENORMAN, OK 73072TEL: 405.360.1300FAX: 405.360.1431

KEYPLAN:

JHOWARD

CO

RD

ELL

PUB

LIC

SC

HO

OLS

2014

BO

ND

- FI

ELD

HO

USE

606

E. T

HIR

D S

TREE

T, C

OR

DEL

L, O

K 73

632

1416

LSF-101

MAY 11, 2015

LIFE SAFETY PLANAND CODEANALYSIS

SCALE: 1/4" = 1'-0"LSF-101REF. TO SHT.:ADD-3.1

1 LIFE SAFETY PLAN AND CODE ANALYSIS - LOCKER ROOMS

NO

RTH

REVISIONSREV DATE DESCRIPTION

1 06/03/2015 FIREMARSHALLREVISIONS

1

1

1

1

1

1

1

1

1

113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
113665
Text Box
113665
Text Box
113665
Text Box
Page 6: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

REF

.

FECC

FEC

D

F7

F7

FCFC

FBFB

FDFD

F6.9

F6.9

F8

F8

F7.4

F7.4

F7.8

F7.8

F8.1

F8.1

F9

F9

F10

F10

F10.9

F10.9

F11

F11

=365 SFE

CONCESSION200

750 SF

ICE

=73 SFE

FAMILYRESTROOM 206

150 SF

=372 SFE

MEN 204

750 SF =578 SFE

WOMEN 205

1250 SF

=69 SFS-2

ELEC 202

00 SF

=49 SFE

TICKETBOOTH 000

1100 SF=146 SFS-2

CONCESSIONSTORAGE 201

250 SF

EWC

200.136"

40.15"

201.136"

00.15"

206.136"

10.15"

000.136"

10.15"

204.136"

70.15"

205.136"

120.15"

202.136"

00.15"

FD

FD

FD

EGRESSPATH L

EGRESSPATH L

EGRESSPATH K EGRESS

PATH M

EGRESSPATH M

EGRESSPATH N

EGRESSPATH N

31'-0"

40'-0"

43'-0"

56'-0"

EGRESSPATH K

FAFA

ALTERNATE #1

ADA

ADA

/1 LSF-101

OCCUPANCY TYPEROOM NAME

SF PER PERSON

NAME ##B ### SF ### SF= ###

ROOM SFROOM NUMBER

OCCUPANCY LOAD

###36"

##0.15"

DOOR NUMBER

DOOR WIDTH

OCCUPANCY LOAD

REQ'D WIDTHPER OCCUPANT

DOOR TAG

ROOM TAG

LIFE SAFETY LEGEND

PARTITION KEY -REFER AC-400 PARTITIONSCHEDULE

1i

EGRESS PATH

FIRE EXTINGUISHER CABINETFEC

ADA ADA PUSH BUTTON DOOROPERATOR

RATED CORRIDOR -REINFORCED, FULLY GROUTEDCMU WALL - 4 HR RATED

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:BWEEKS

BWEEKS

PARTNERSHIP

ARCHITECTSIN

SEAL:

ARCHITECTSINTERIOR DESIGNERSPLANNERS

3220 MARSHALL AVENUENORMAN, OK 73072TEL: 405.360.1300FAX: 405.360.1431

KEYPLAN:

JHOWARD

CO

RD

ELL

PUB

LIC

SC

HO

OLS

2014

BO

ND

- FI

ELD

HO

USE

606

E. T

HIR

D S

TREE

T, C

OR

DEL

L, O

K 73

632

1416

LSF-102

MAY 11, 2015

LIFE SAFETY PLANAND CODEANALYSIS

SCALE: 1/4" = 1'-0"LSF-102REF. TO SHT.:ADD-3.1

1 LIFE SAFETY PLAN AND CODE ANALYSIS - CONCESSIONS

REVISIONSREV DATE DESCRIPTION

1 06/03/2015 FIREMARSHALLREVISIONS

1

113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
Page 7: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

WD

REF

.

FECA

FECB FECC

OS

4

4

4

4 33

33

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OS

OS

PS

REF

.

FECC

FEC

D

OS

OS

OSOS

OS

OS

OS

PS

ELEC103

JANITOR106

COACHES OFFICE108

WEIGHT ROOM111

TOILETS102

TOILETS105

CORRIDOR100

VARSITY LOCKER ROOM101

EQUIPMENT STORAGE107

TAPE ROOM110

COACHES DRESSING109

UnoccupiedUnoccupied AAAAA

A2

A2

CC

CC

A2

A2

B B

A

A

A

A

A

A

AA

CC

A A

A

B B

B B

B B

AA

A

A A A

A A A

A A A

A AA

C2

DDDDDDD

C2G

G

F-21

a

F-21

F-21

F-21F-21

F-21 F-21

F-21F-21

F-21

F-21

F-21

F-22F-22F-22

F-22 F-22 F-22 F-22F-22

F-24 F-24

F-24F-24

F-24 F-24

F-24

F-24F-23

F-23 F-23F-25 F-25 F-25

F-25F-25F-25

F-25 F-25 F-25

F-25F-25F-25

F-27

F-27

F-27 F-27 F-27 F-27 F-27 F-27 F-27

a

a

bb

b ba

a

a

b

b

ba

ab

a

a

b b

F-24

F-24

F-24

F-26 F-26 F-26 F-26 F-26 F-26

C-13C-13C-13C-13D D D D

1

1

1

2 2 2 2

F-22F-24

b

F-24

F-24

DDDDDD

F

F

F-23

F-23 F-23 F-23

F-23F-23F-23

3

3

3

3

F1 F7F2 F3 F4 F5 F6

FC

FB

F6.9F3.9F2.1

FA

TICKET BOOTH000

WEIGHT ROOM111

MEN204

CONCESSION STORAGE201

ELEC202

FAMILY RESTROOM206

WOMEN205

CONCESSION200

G

A

A

A

AA

C2C2 C2 C2

D

DD

D D D D

DDD

C2C2

C2 C2C2 C2 C2

F

F

A

A

A

A

A

A

A

A

AA

A

A

A

A

AA A

C3 C3

C3

C3C3

C3

C3

C3 C3

C3

F-25

F-25

F-25

F-25

F-27

C-12

C-12

C-12

C-12

C-12

C-12C-12

C-12

C-12

C-12

C-12

C-12

C-12

C-13

C-13

C-13 C-13 C-13 C-13

C-13 C-13

C-11C-14

C-14

C-14 C-11

C-11

C-14

C-14

C-11

C-11C-10C-10C-10

C-10

C-10

C-10

C-10

C-13

C-13

C-13C-13C-13C-13

C-13 C-13

a

F-26

C-13C-13D D

11 1

1

2 2

C-12 C-12 C-12 C-12

C-11

D

c

D

H2

H

H2C-13

C-35

C-133

4

3

F7

FC

FB

FD

F6.9 F8F7.4 F7.8 F8.1 F9 F10 F10.9F11

FA

5 5 5 5 5 5 5 5 5

C-35 C-35 C-35 C-35 C-35 C-35 C-35 C-35 C-35

C-35

C-35

I

H

H

I I I I I I I I

EXHAUST FAN SHALL BE CONTROLLED FROM SWITCH CONTROLLINGLIGHTS ON CIRCUIT

FIXTURES SHALL BE ON CIRCUIT FROM CONCESSION BUILDING.PILLARS AND FIXTURES ARE PART OF DEDUCT ALTERNATE.

UPLIGHT FOR SIGNAGE. VERIFY WITH ARCHITECT FOR EXACTLOCATION.

UPLIGHT FOR FLAG. VERIFY WITH ARCHITECT FOR EXACT LOCATION.FIXTURES. SHALL BE PLACED AT 1/3 OF HEIGHT OF POLE AWAY FROMBASE OF POLE. FIXTURES SPACED EVENLY AROUND POLE. POINTFIXTURE DIRECTLY AT FLAG.

BOLLARD FIXTURES. VERIFY WITH ARCHITECT FOR EXACT LOCATION.

KEYED NOTES1

2

3

4

5

1. ALL OUTDOOR LIGHTING SHALL BE RAN FROM PHOTOCELL/TIMECLOCK.SEE DETAIL.

GENERAL NOTES

22699L

OR

NIC

ESE

D

P

K AMOL A OH

RE

ESF S I OLAN

EN

EG

IN

STEVEWEDEMEYER

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:

AL

PARTNERSHIP

ARCHITECTSIN

SEAL:

DATEREV. DESCRIPTION

REVISIONS

ARCHITECTSINTERIOR DESIGNERSPLANNERS

3220 MARSHALL AVENUENORMAN, OK 73072TEL: 405.360.1300FAX: 405.360.1431

KEYPLAN:

A16.14.10MEP PROJECT NO.:

CA#: 5121 Expiration Date: 06.30.2015

CO

RD

ELL

PUB

LIC

SC

HO

OLS

NEW

FIE

LD H

OU

SE A

ND

STE

M C

LASS

RO

OM

BU

ILD

ING

S60

6 E.

TH

IRD

STR

EET,

CO

RD

ELL,

OK

7363

2

1416

EF-101

APR. 22, 2015

ELECTRICALLIGHTING PLAN

SJW

TDM

1/8" = 1'-0"

LIGHTING PLAN - LOCKER ROOMS1

1/8" = 1'-0"

LIGHTING PLAN - CONCESSIONS2

113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
Page 8: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:JL/KE

KE

PARTNERSHIP

ARCHITECTSIN

SEAL:

DATEREV. DESCRIPTION

REVISIONS

ARCHITECTSINTERIOR DESIGNERSPLANNERS

3220 MARSHALL AVENUENORMAN, OK 73072TEL: 405.360.1300FAX: 405.360.1431

KEYPLAN:

MS

2014

B ON

D-F

IELD

HO

US E

606

E.TH

IRD

STR

EET,

CO

RD

ELL,

OK

7363

2

1416

SF-000

APR. 22, 2015

GENERAL NOTES

GENERAL NOTESCOLD FORMED METAL FRAMING

1. ANY METAL STUD WALLS SHALL BE SPACED AT A MAXIMUM OF 16" ON CENTER (U.N.O.) AND SHALL BECONSTRUCTED OF STEEL "C" STUDS OF THE SIZE SHOWN IN THE PLANS. MINIMUM WIDTH OF THE STUDSSHALL BE 1 5/8" AND THE LIP OF THE "C" PORTION SHALL BE A MINIMUM OF 1/2". YIELD STRENGTH SHALLBE AS FOLLOWS: 33 KSI FOR 18 GAGE AND LIGHTER, 50KSI FOR 16 GAGE AND HEAVIER. MINIMUM GROSSSECTION PROPERTIES SHALL BE BASED ON UNIMAST CSJ SECTIONS.

2. WALL STUDS AS BACKING TO MASONRY VENEER SHALL SHALL HAVE A MINIMUM THICKNESS OF 43 MILS(18 GA).

3. METAL FRAMING SHALL BE IN ACCORDANCE WITH THE FOLLOWING, UNLESS NOTED OTHERWISE:A. 54 MILS (16 GA) AND HEAVIER ASTM A1003, GRADE 50 TYPE H (ST50H)B. 43 MILS (18 GA) AND LIGHTER ASTM A1003, GRADE 33 TYPE H (ST33H)C. ACCESSORIES, TRACK AND OTHER MEMBERS ASTM A1003, GRADE 33 TYPE H (ST33H), MINIMUM

4. DO NOT WELD 33 MILS (20 GA) AND LIGHTER FRAMING, UNLESS SPECIFICALLY NOTED IN THE CONTRACTDOCUMENTS.

5. METAL FRAMING SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTENRECOMMENDATIONS. HORIZONTAL BRACING FOR WALL STUDS SHALL BE PLACED AT 48 INCHES ONCENTER OR AS PER MANUFACTURER'S WRITTEN RECOMMENDATIONS IF LESS THAN 48 INCHES ONCENTER. HORIZONTAL BRIDGING FOR JOISTS SHALL BE PLACED AT 8'-0" ON CENTER OR AS PERMANUFACTURER'S WRITTEN RECOMMENDATIONS IF LESS THAN 8'-0" ON CENTER. APPLIED FINISHMATERIALS SHALL NOT BE CONSIDERED BRIDGING OR FLANGE BRACING UNLESS NOTED OTHERWISE INTHE CONTRACT DOCUMENTS.

6. ALL AXIALLY LOADED WALL STUDS SHALL HAVE FULL FLANGE BEARING AGAINST UPPER AND LOWERTRACK WEB PRIOR TO ATTACHMENT TO TRACK. SPLICES IN AXIALLY LOADED WALL STUDS ARE NOTALLOWED.

9. TRACK SHALL BE 54 MILS (16 GA) MINIMUM FOR WALL STUDS 54 MILS (16 GA) OR LIGHTER. TRACK SHALLMATCH WALL STUD THICKNESS FOR WALL STUDS 68 MILS (14 GA) AND HEAVIER. TRACKS SHALL BEANCHORED AS FOLLOWS:TO STEEL - HILTI X-U, 0.157 INCH DIAMETER KNURLED SHANK FASTENERS AT 12 INCHES ON CENTER(ESR-2269) OR APPROVED EQUAL, UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS.TO CONCRETE - HILTI X-U, 0.157 INCH DIAMETER KNURLED SHANK FASTENERS AT 8 INCHES ON CENTERWITH 1 1/2 INCH EMBEDMENT (ESR-2269) OR APPROVED EQUAL, UNLESS NOTED OTHERWISE INCONTRACT DOCUMENTS.

10. CONNECTIONS SHALL CONSIST OF ANY OF THE FOLLOWING AS NOTED IN THE CONTRACT DOCUMENTS:A. SELF-DRILLING SCREWS OF TYPE AND SIZE AS SHOWN IN THE CONTRACT DOCUMENTS.B. WELDS SHALL BE PERFORMED BY OPERATORS QUALIFIED IN ACCORDANCE WITH SECTION 6.0 OF AWSD1.3, SHEET METAL.

GENERAL NOTESMASONRY

1. CONCRETE MASONRY UNITS SHALL MEET ASTM SPECIFICATION C90, GRADE N TYPE I BLOCK WITH AMINIMUM UNIT COMPRESSIVE STRENGTH = 1900 PSI. THE SPECIFIED DESIGN COMPRESSIVE STRENGTHOF THE CONCRETE MASONRY ASSEMBLY (f'm) SHALL BE 1500 PSI.

2. MORTAR SHALL MEET ASTM SPECIFICATION C270 FOR TYPE "S" MORTAR.3. GROUT SHALL MEET ASTM SPECIFICTION C476 AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH

OF 2000 PSI.4. GROUT PLACED BY THE LOW LIFT GROUTING METHOD SHALL BE MECHANICALLY CONSOLIDATED USING A

VIBRATOR WITH A MAXIMUM 3/4 INCH DIAMETER HEAD. REFERENCE THE CONCRETE UNIT MASONRYSPECIFICATION FOR HIGH LIFT GROUTING PROCEDURES.

5. HORIZONTAL JOINT REINFORCEMENT SHALL BE LADDER TYPE (REFERENCE THE CONCRETE UNITMASONRY SPECIFICATION). JOINT REINFORCEMENT SHALL BE SPACED AT 8 INCHES ON CENTER BELOWFINISHED FLOOR AND IN PARAPETS, AND 16 INCHES ON CENTER ABOVE FINISHED FLOOR.

6. CONCRETE MASONRY SHALL BE LAID IN RUNNING BOND.7. CONCRETE MASONRY BELOW FINISHED FLOOR SHALL BE NORMAL WEIGHT UNITS AND SHALL HAVE ALL

THE CELLS FULLY GROUTED. CONCRETE MASONRY ABOVE FINISHED FLOOR SHALL BE NORMAL WEIGHTOR LIGHT WEIGHT AND IS TO BE GROUTED ONLY AT REINFORCED CELLS AND BOND BEAMS. ALL CELLSWITH REINFORCING SHALL BE GROUTED SOLID.

8. REFER TO WALL SECTIONS AND DETAILS FOR MISCELLANEOUS BOND BEAM LOCATIONS AND EMBEDDEDITEMS. USE OPEN KNOCK OUT BOND BEAM BLOCK. DO NOT USE TROUGH TYPE BLOCKS FOR BONDBEAMS. DO NOT CONTINUE BOND BEAM REINFORCING THROUGH CONTROL JOINTS.

9. REINFORCING STEEL SHALL MEET ASTM SPECIFICATION A615, GRADE 60.10. ANCHORS INSTALLED IN GROUT FILLED CONCRETE MASONRY UNITS SHALL ONLY BE USED WHERE

SPECIFIED IN THE CONTRACT DOCUMENTS . ANCHORS MUST BE INSTALLED IN ACCORDANCE WITH THEMANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. USE HILTI HIT-HY 70 MAX ADHESIVEANCHORING SYSTEM (OR HILTI HIT ICE ADHESIVE ANCHORING SYSTEM OR HILTI KWIK BOLT 3 EXPANSIONANCHOR). REFERENCE CONTRACT DOCUMENTS FOR ANCHOR SIZE AND EMBEDMENT. SUBSTITUTIONS TOTHE SPECIFIED ANCHORS MUST BE APPROVED BY THE ENGINEER-OF-RECORD.

11. CONSTRUCTION BRACING FOR MASONRY WALLS SHALL BE DESIGNED AND DETAILED BY APROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED. MASONRYSUBMITTALS SHALL CONTAIN A LETTER, SEALED BY THE PROFESSIONAL ENGINEER RESPONSIBLE FORTHEIR PREPARATION, STATING DESIGN LOADS AND CRITERIA WHICH WERE USED IN BRACING DESIGN.THE BRACING DESIGN DRAWINGS SHALL BE SIGNED AND SEALED BY THE PROFESSIONAL ENGINEERRESPONSIBLE FOR THEIR PREPARATION AND SHALL BE ISSUED TO THE OWNER AFTER SUBMITTALREVIEW AND PRIOR TO STARTING MASONRY CONSTRUCTION.

12. PROVIDE GALVANIZED L4x4X3/8 STEEL LINTEL IN MASONRY VENEER AS REQUIRED. MAXIMUM CLEARSPAN = 4'-0" AND GALVANIZED L5x5x3/8 MAXIMUM CLEAR SPAN = 8'-0". ANGLE TO BEAR ON MASONRYVENEER 8" EACH SIDE TYP., U.N.O.

STRUCTURAL STEEL

1. STRUCTURAL STEEL SHALL MEET THE FOLLOWING MINIMUM YIELD STRESS (Fy):. YIELD ASTM SPECIFICATIONA. W, WT SHAPES: 50 KSI A992B. BARS, PLATES, CHANNELS, ANGLES: 36 KSI A36C. SQUARE, RECTANGULAR HSS: 46 KSI A500, GRADE BD. ROUND HSS: 42 KSI A500, GRADE BE. STRUCTURAL STEEL PIPE: 35 KSI A53, GRADE BF. ANCHOR RODS: 36 KSI F1554 GR 36G. ALL-THREAD RODS: 36 KSI A36H. HEADED STUD ANCHORS: 65 KSI TENSILE STRESS A108, GRADES 1010-1020

2. BOLTS FOR STEEL BEAM AND COLUMN CONNECTIONS SHALL BE 3/4-INCH DIAMETER ASTM A325-NHIGH-STRENGTH BOLTS UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS. ALL BOLTEDCONNECTIONS ARE BEARING TYPE UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS. ALL BOLTSSHALL BE TIGHTENED SNUG TIGHT UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS . FORPRETENSIONED OR SLIP-CRITICAL JOINTS, THE METHOD OF INSTALLATION SHALL BE TURN-OF-NUT WITHMATCH MARKING, TWIST-OFF-TYPE TENSION CONTROL BOLT ASSEMBLIES (ASTM F1852), OR DIRECTTENSION INDICATORS (ASTM F959).

3. WELDING SHALL MEET ANSI / AWS D1.1, STRUCTURAL WELDING CODE LATEST REVISION. ELECTRODESSHALL BE 70 KSI, LOW HYDROGEN.

4. PROVIDE DOUBLE NUTS AND DOUBLE WASHERS FOR STEEL COLUMN ANCHOR BOLTS TO ALLOW FORADJUSTMENT IN BASE PLATE ELEVATION. PROVIDE 1 1/2 INCH NON-SHRINK GROUT UNDER BASE PLATEAFTER ERECTION. USE 2 1/2 INCH NON-SHRINK GROUT WHEN COLUMN ANCHOR BOLTS ARE 1 1/4 INCHDIAMETER OR LARGER. NON-SHRINK GROUT SHALL BE NON-METALLIC WITH A MINIMUM COMPRESSIVESTRENGTH OF 5,000 PSI AT 28 DAYS.

5. ALL CONNECTIONS NOT FULLY DETAILED IN THE CONTRACT DOCUMENTS SHALL BE DESIGNED ANDDETAILED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED,EMPLOYED OR RETAINED BY THE STEEL FABRICATOR. THE DESIGN AND DETAILING SHALL COMPLY WITHALL APPLICABLE CODES AND SPECIFICATION SECTIONS.

6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INCLUDING THE COSTS FOR ALLMISCELLANEOUS STEEL SHOWN IN THE CONTRACT DOCUMENTS. THESE COSTS SHALL INCLUDE, BUTARE NOT LIMITED TO, MISCELLANEOUS STEEL ITEMS SHOWN ON THE STRUCTURAL, ARCHITECTURAL,CIVIL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.

7. INCLUDE AN ALLOWANCE IN THE BID PRICE FOR 1500 POUNDS OF MISCELLANEOUS STRUCTURAL STEELTO BE FABRICATED AND PLACED AS DIRECTED BY THE ARCHITECT OR ENGINEER. ALLOWANCE IS TOINCLUDE, BUT IS NOT LIMITED TO: MATERIAL, DETAILING, FABRICATION, SHIPPING, INSTALLATION,OVERHEAD AND PROFIT.

8. PROVIDE L5x3x1/4 (LLV) FIELD FABRICATED FRAMES BETWEEN JOISTS AT OPENINGS IN ROOF THAT AREGREATER THAN 10"x10", U.N.O., (INCLUDING ROOF DRAINS, EXHAUST FANS, RE: SF-300, AND SC-300 FOROPENINGS AT RTU'S AND ROOF HATCHES).

STEEL JOISTS (AND JOIST GIRDERS)

1. STEEL JOISTS (AND JOIST GIRDERS) SHALL BE AS INDICATED ON THE PLANS AND SHALL BE INACCORDANCE WITH THE SPECIFICATIONS OF THE STEEL JOIST INSTITUTE (SJI) AND MEET THEFOLLOWING:A. JOISTS SHALL BE DESIGNED FOR THE UNIFORM LOAD CAPACITY (AS SPECIFIED IN THE SJI STANDARDLOAD TABLES) IN ADDITION TO THE CONCENTRATED LOADS SHOWN IN THE CONTRACT DOCUMENTS.B. JOISTS THAT SUPPORT CONCENTRATED LOADS SHALL HAVE THEIR CHORDS DESIGNED TOWITHSTAND ALL BENDING STRESSES, OR THE LOADS SHALL OCCUR WITHIN 3 INCHES OF JOIST PANELPOINTS, OR THE JOIST SHALL BE REINFORCED PER THE "JOIST REINFORCING DETAIL" SHOWN HEREIN.CONCENTRATED LOADS SHALL BE CENTERED ON JOISTS AND NOT ATTACHED TO THE EDGE OF CHORDANGLES.C. JOISTS (AND JOISTS GIRDERS) SHALL RESIST THE NET UPLIFT PRESSURE AS INDICATED ON THE"ROOF (NET UPLIFT)" SECTION OF THE DESIGN PARAMETERS FOR "DESIGN WIND PRESSURE ONCOMPONENTS AND CLADDING". THIS PRESSURE SHALL ACT ALONE. AN ALLOWABLE STRESS INCREASEIS NOT PERMITTED.D. FOR ALL MEMBERS THAT REQUIRE SPECIFIC ORIENTATION, PROVIDE TAG AT ONE END AND DEFINELOCATION OF TAGGED END ON ERECTION DRAWINGS.E. JOIST (AND JOIST GIRDER) MANUFACTURER SHALL DETERMINE THE SEAT DEPTH AND WIDTH OFBEARING AND COORDINATE THE SAME WITH THE STEEL FABRICATOR. THE FOLLOWING SEAT DEPTHSARE ASSUMED IN THE CONTRACT DOCUMENTS: 2 1/2 INCH FOR K-SERIES JOISTS (5 INCH FOR LH AND DLHSERIES JOISTS) (7 1/2 INCH FOR JOIST GIRDERS).

2. K-SERIES JOISTS SHALL BE WELDED TO SUPPORTING STEEL WITH MINIMUM 1/8 INCH FILLET WELDS 2INCHES LONG EACH SIDE OR WITH TWO 1/2 INCH DIAMETER ASTM A307 BOLTS OR THE EQUIVALENT,UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS. WHEN NEAR OR AT A COLUMN, BOLT JOIST TOSUPPORTING STEEL IN CONFORMANCE WITH OSHA. LH AND DLH-SERIES JOISTS SHALL BE WELDED TOSUPPORTING STEEL WITH MINIMUM 1/4 INCH FILLET WELDS 2 INCHES LONG EACH SIDE OR WITH TWO 3/4INCH DIAMETER ASTM A307 BOLTS OR THE EQUIVALENT, UNLESS NOTED OTHERWISE IN CONTRACTDOCUMENTS.

3. JOIST BRIDGING AND ERECTION STABILITY SHALL BE PROVIDED IN ACCORDANCE WITH THEOCCUPATIONAL SAFETY AND HAZARD ADMINISTRATION (OSHA) AND THE SPECIFICATIONS OF THE STEELJOIST INSTITUTE (SJI).

4. JOIST RTU LOADS ARE PROVIDED ON THE ROOF FRAMING PLAN, REFERENCE CONTRACT DOCUMENTSFOR LOAD LOCATIONS, VALUES AND SUPPORT FRAMING.

5. JOIST MANUFACTURER SHALL DESIGN THE COMPRESSION CHORD OF ALL JOISTS SUPPORTING ROOFTOP UNITS, SKY LIGHTS, AND OTHER STRUCTURES FOR AN UNBRACED LENGTH APPLICABLE TO THECONDITIONS AT THE PROJECT WHERE THE UNBRACED LENGTH IS GREATER THAN THE SJI MAXIMUM.(REFERENCE ARCHITECTURAL AND MECHANICAL DRAWINGS)

6. DESIGN JOISTS FOR INTERNAL ROOF DRAINLINE LOCATIONS, IF REQUIRED. ADD 50 PLF FOR 8 INCHDIAMETER AND SMALLER, ADD 75 PLF FOR 10 INCH DIAMETER, ADD 102 PLF FOR 12 INCH DIAMETER, ADD122 PLF FOR 14 INCH DIAMETER, ADD 200 PLF FOR 18 INCH DIAMETER. REFERENCE MECHANICAL ANDPLUMBING DRAWINGS FOR EXACT LOCATION.

7. JOIST DESIGNS SHALL BE PERFORMED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERETHE PROJECT IS LOCATED, EMPLOYED OR RETAINED BY THE JOIST MANUFACTURER.

8. SHOP DRAWING SHALL BE REVIEWED BY THE ARCHITECT AND THE ENGINEER-OF-RECORD PRIOR TOJOIST FABRICATION.

STEEL DECK

1. ROOF DECKA. ROOF DECK SHALL BE GALVANIZED 1.5 INCH TYPE "B" OR 3 INCH TYPE "N". DEPTH SHALL BE ASSHOWN IN THE CONTRACT DOCUMENTS.B. ROOF DECK IS REQUIRED TO ACT AS A DIAPHRAGM. CONNECTIONS SHALL BE IN ACCORDANCE WITHSTEEL DECK INSTITUTE SPECIFICATIONS. REFER TO THE ROOF DIAPHRAGM CONNECTION DIAGRAM FORATTACHMENT.C. DECKING SHALL BE CONTINUOUS OVER A MINIMUM OF (3) SPANS UNLESS NOTED OTHERWISE IN THECONTRACT DOCUMENTS.D. NO HANGING LOADS SHALL BE ATTACHED TO ROOF DECK.

2. FLOOR DECKA. COMPOSITE FLOOR DECK SHALL BE GALVANIZED COMPOSITE STEEL DECK. DEPTH SHALL BE ASSHOWN IN THE CONTRACT DOCUMENTS.B. CONNECTIONS SHALL BE IN ACCORDANCE WITH STEEL DECK INSTITUTE SPECIFICATIONS AND ASFOLLOWS:1) RE: ROOF FRAMING PLAN FOR DECK ATTACHMENT REQUIREMENTS.2) DECKING SHALL BE CONTINUOUS OVER A MINIMUM OF (3) SPANS, UNLESS NOTED OTHERWISE INCONTRACT DOCUMENTS.

GENERAL NOTESGENERAL

1. STRUCTURAL ELEMENTS ARE NON-SELF SUPPORTING AND REQUIRE INTERACTION WITH OTHERELEMENTS FOR STABILITY AND RESISTANCE TO LATERAL FORCES. FRAMING AND WALLS SHALL BETEMPORARILY BRACED BY THE CONTRACTOR UNTIL PERMANENT BRACING, FLOOR AND ROOF DECKS,AND WALLS HAVE BEEN INSTALLED AND CONNECTIONS BETWEEN THESE ELEMENTS HAVE BEEN MADE.

2. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THEMETHOD OF CONSTRUCTION, UNLESS NOTED OTHERWISE. THE CONTRACTOR IS SOLELY RESPONSIBLEFOR THE MEANS, METHODS, TECHNIQUES, SEQUENCES, AND OPERATION OF CONSTRUCTION ANDSAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO.

3. THE SIZE AND LOCATION OF EQUIPMENT PADS AND PENETRATIONS THROUGH THE STRUCTURE FORMECHANICAL, ELECTRICAL, AND PLUMBING WORK SHALL BE VERIFIED BY THE CONTRACTOR.PENETRATIONS SHALL BE SUBJECT TO APPROVAL BY THE ENGINEER-OF-RECORD. REFER TOMECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR OPENING LOCATIONS NOT SHOWN ON THESTRUCTURAL DRAWINGS.

4. USE ONLY DIMENSIONS INDICATED IN THE CONTRACT DOCUMENTS. DO NOT SCALE CONTRACTDOCUMENTS OR USE ANY DIMENSIONS TAKEN FROM ELECTRONIC DRAWING FILES.

5. ASSUME EQUAL SPACING IF NOT INDICATED IN CONTRACT DOCUMENTS.6. THE SPECIFICATIONS ARE AN INTEGRAL PART OF THE CONTRACT DOCUMENTS AND SHALL BE USED IN

CONJUCTION WITH THE CONTRACT DRAWINGS. WHERE REQUIREMENTS INDICATED ON THE CONTRACTDRAWINGS DIFFER FROM THE SPECIFICATIONS, NOTIFY THE ARCHITECT AND THEENGINEER-OF-RECORD.

7. ARCHITECTURAL, MECHANICAL AND ELECTRICAL COMPONENTS AND SYSTEMS SHALL BE DESIGNED ANDCONSTRUCTED TO RESIST SEISMIC FORCES AS DETERMINED IN CHAPTER 13 OF ASCE 7.

8. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE TEMPORARY SUPPORT AND STABILITYOF EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION.

9. DURING WELDING OR ANY OTHER CONSTRUCTION ACTIVITY THAT GENERATES SPARKS OR INTENSEHEAT, THE CONTRACTOR SHALL PROVIDE ADEQUATE FIRE PROTECTION TO THE EXISTING STRUCTUREAND CONTENTS.

FOUNDATIONS

1. FOUNDATION DESIGNS, SUBGRADE PREPARATION NOTES, AND STRUCTURAL EARTH MOVINGSPECIFICATION ARE BASED ON THE RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORTNUMBER 731-14148A AND 731-14148B, BY: BURGESS ENGINEERING AND TESTING, INC. DATED: OCTOBER29, 2014.

2. FOOTING DESIGNS ARE BASED ON A MAXIMUM ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF FORCOLUMN FOOTINGS AND 1,400 PSF FOR WALL FOOTINGS.

3. CONTRACTOR AND TESTING LABORATORY REPRESENTATIVE SHALL READ THE GEOTECHNICAL REPORTAND BECOME THOROUGHLY FAMILIAR WITH SITE AND SUBGRADE INFORMATION GIVEN THEREIN. THECONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING EXACT QUANTITIES OF CUT AND FILL FORESTIMATING AND CONSTRUCTION. SUBGRADE SHALL BE PREPARED AS NOTED IN THE STRUCTURALEARTH MOVING SPECIFICATION.

4. A QUALIFIED AND REGISTERED GEOTECHNICAL ENGINEER, LICENSED IN THE STATE WHERE THEPROJECT IS LOCATED AND WORKING FOR THE TESTING LABORATORY, SHALL DETERMINECONFORMANCE OF THE FOUNDATION BEARING STRATA WITH THE FOUNDATION DESIGN CRITERIAABOVE, AND ALL OTHER CONTRACT DOCUMENTS. TESTING LABORATORY SHALL NOTIFY CONTRACTOR,ARCHITECT AND ENGINEER-OF-RECORD OF ANY CONDITIONS NOT IN ACCORDANCE WITH FOUNDATIONDESIGN CRITERIA OR CONTRACT DOCUMENTS.

5. USE ONLY STRUCTURAL FILL MATERIAL AS NOTED IN THE STRUCTURAL EARTH MOVING SPECIFICATIONFOR FILL BELOW BUILDING AND FIVE FEET BEYOND THE EDGES OF THE BUILDING.

6. EXTERIOR FOOTINGS SHALL BEAR AT OR BELOW MINIMUM BEARING DEPTH. MINIMUM BEARING DEPTH IS24 INCHES BELOW ADJACENT FINISHED GRADE. THICKENED SLAB EDGE FOR STOOPS, CANOPIES, ETC.SHALL EXTEND 24 INCHES BELOW GRADE UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS.

7. FOUNDATION WALLS SHALL HAVE ADEQUATE TEMPORARY BRACING INSTALLED BY THE CONTRACTORBEFORE BACKFILL IS PLACED AGAINST THEM. TEMPORARY BRACING SHALL NOT BE REMOVED UNTILWALL IS PERMANENTLY BRACED.

8. AVOID DAMAGE TO UNDERGROUND UTILITIES INCLUDING, BUT NOT LIMITED TO, WATER MAINS, SANITARYSEWERS AND BURIED CABLES WHICH MIGHT EXTEND ACROSS OR ADJOIN SITE.

CONCRETE

1. MINIMUM COMPRESSIVE STRENGTH (f'c) AT THE END OF 28 DAYS SHALL BE AS FOLLOWS:A. FOOTINGS 3000 PSIB. FOUNDATION WALLS AND PEDESTALS 4000 PSIC. SLABS-ON-GRADE 3000 PSI

REFER TO SPECIFICATIONS FOR MAXIMUM WATER/CEMENT RATIOS, MINIMUM CEMENT CONTENTS ANDOTHER MIX DESIGN REQUIREMENTS. CONCRETE SHALL BE NORMAL WEIGHT (145 PCF), UNLESS NOTEDOTHERWISE.

2. EXTERIOR CONCRETE AND CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL BE AIR-ENTRAINED.REFER TO CAST-IN-PLACE CONCRETE SPECIFICATION FOR AIR CONTENT.

3. MATERIALS OR ADMIXTURES SHALL NOT CONTAIN ANY CALCIUM CHLORIDE.4. REINFORCING STEEL SHALL MEET THE FOLLOWING:

A. DEFORMED BARS ASTM A615, GRADE 60B. WELDABLE DEFORMED BARS ASTM A706, GRADE 60C. WELDED WIRE FABRIC ASTM A185D. STEEL FIBERS ASTM A820

5. WHERE DOWELS ARE INDICATED BUT NOT SIZED, PROVIDE DOWELS THAT MATCH SIZE AND LOCATION OFMAIN REINFORCING STEEL AND LAP SPLICE WITH THE MAIN REINFORCING STEEL. REINFORCING BARSSHALL BE SPLICED AS NOTED IN THE REINFORCING LAP SCHEDULE.

6. REFER TO ACI 318 LATEST EDITION FOR CONCRETE COVER, ACI 315 LATEST EDITION FOR DETAILINGPRACTICES AND FABRICATION, AND ACI 301 LATEST EDITION FOR STANDARD PRACTICE FOR MIXING ANDPLACING CONCRETE.

7. "C.J." INDICATES SAW CUT CONTRACTION JOINT OR DOWELED CONSTRUCTION JOINT IN SLAB-ON-GRADE.REFERENCE CAST-IN-PLACE CONCRETE SPECIFICATION FOR ACCEPTED SAW CUT METHODS. SLABPOURS SHALL BE SEPARATED BY A DOWELED CONSTRUCTION JOINT. CONTRACTION/CONSTRUCTIONJOINTS SHALL BE LOCATED AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER-OF-RECORD.

8. PROVIDE CORNER BARS THAT MATCH AND LAP CONTINUOUS REINFORCEMENT SIZE AND QUANTITY ATINTERSECTIONS AND CORNERS OF WALLS AND FOUNDATIONS.

9. ANCHORS INSTALLED IN HARDENED CONCRETE SHALL ONLY BE USED WHERE SPECIFIED ON THECONTRACT DRAWING. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER-OF-RECORDPRIOR TO INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACEANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITHEXISTING REINFORCING. HOLES SHALL BE DRILLED, DRY AND CLEANED AND ANCHORS INSTALLED INACCORDANCE WITH THE MANUFACTURER’S PUBLISHED WRITTEN INSTRUCTIONS AND APPLICABLE ESRREPORT. REFERENCE DETAILS FOR ANCHOR SIZE AND EMBEDMENT. SUBSTITUTION REQUESTS FORPRODUCTS OTHER THAN THOSE SPECIFIED ON THE CONTRACT DRAWINGS SHALL BE SUBMITTED BY THECONTRACTOR TO THE ENGINEER-OF-RECORD ALONG WITH CALCULATIONS THAT ARE SIGNED ANDSEALED BY THE PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION AND LICENSED INTHE STATE WHERE THE PROJECT IS LOCATED.

11. INCLUDE AN ALLOWANCE IN THE BID PRICE FOR 1000 POUNDS OF REINFORCING STEEL TO BEFABRICATED AND PLACED AS DIRECTED BY THE ARCHITECT OR ENGINEER. ALLOWANCE IS TO INCLUDE,BUT IS NOT LIMITED TO: MATERIAL, DETAILING, FABRICATION, SHIPPING, INSTALLATION, OVERHEAD ANDPROFIT.

DESIGN PARAMETERS (EXCLUDING SAFEROOM)1. BUILDING CODE IBC 2009

LOCAL AMENDMENTS N/A STRUCTURALOCCUPANCY CATEGORY III

2. LIVE LOADS (UNIFORM/CONCENTRATED)A. ROOF 20 PSF / 300 LB

3. ROOF SNOW LOADA. GROUND SNOW LOAD, Pg 10 PSFB. FLAT ROOF SNOW LOAD, Pf 7 PSFC. SNOW EXPOSURE FACTOR, Ce 1.0D. SNOW LOAD IMPORTANCE FACTOR, I 1.0E. THERMAL FACTOR, Ct 1.0

4. WIND DESIGN DATAA. BASIC WIND SPEED (3 SECOND GUST), V 90 MPHB. WIND IMPORTANCE FACTOR, I 1.15C. WIND EXPOSURE CATEGORY CD. INTERNAL PRESSURE COEFFICIENT, GCpi +/- 0.18E. DESIGN WIND PRESSURE ON COMPONENTS AND CLADDING

1.) WALLS ( 60 SQUARE FEET EFFECTIVE WIND AREA)END ZONES 20.5 PSFINTERIOR ZONES 18 PSF2.) PARAPETS (10 SQUARE FEET EFFECTIVE WIND AREA)END ZONES 65 PSFINTERIOR ZONES 48 PSF3.) ROOF NET UPLIFT (340 SQUARE FEET EFFECTIVE WIND AREA)CORNER ZONES 16 PSFEND ZONES 16 PSFINTERIOR ZONES 12 PSF

F. WIDTH OF END ZONE 5.4 FT

5. EARTHQUAKE DESIGN DATAA. SEISMIC IMPORTANCE FACTOR, I 1.25B. MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 20.8%C. MAPPED SPECTRAL RESPONSE ACCELERATION, S1 7.3%D. SITE CLASS CE. SPECTRAL RESPONSE COEFFICIENT, Sds .166F. SPECTRAL RESPONSE COEFFICIENT, Sd1 .083G. SEISMIC DESIGN CATEGORY BH. STRUCTURAL SYSTEM --

1.) BASIC SEISMIC FORCE-RESISTING SYSTEM TYPE B. BEARING WALL SYSTEM2.) VERTICAL ELEMENT TYPE INTERMEDIATE SHEAR WALLS3.) SEISMIC RESPONSE COEFFICIENT, Cs .1044.) RESPONSE MODIFICATION FACTOR, R 2

J. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE

DEFERRED STRUCTURAL SUBMITTALS

1. THE FOLLOWING STRUCTURAL COMPONENTS SHALL BE DESIGNED AND SUBMITTED BY OTHERS FOR APPROVAL IN ACCORDANCE WITH THECONTRACT DOCUMENTS.A. STOREFRONT AND CURTAINWALL FRAMING, ACCESSORIES, AND ATTACHMENTS TO STRUCTURE.

2. DOCUMENTS FOR DEFERRED STRUCTURAL SUBMITTAL ITEMS SHALL BE DESIGNED, SEALED AND SIGNED BY A PROFESSIONAL ENGINEERLICENSED IN THE STATE WHERE THE PROJECT IS LOCATED. THE DEFERRED SUBMITTAL DOCUMENTS SHALL BE SUBMITTED TO THE ARCHITECT ORENGINEER-OF-RECORD WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL AS REQUESTED WITH A NOTATION INDICATINGTHAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED FOR DESIGN LOADS AND BEEN FOUND TO BE IN GENERAL CONFORMANCETO THE DESIGN CRITERIA OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTALDOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL.

SPECIAL INSPECTIONS

1. THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORKLISTED IN THE STATEMENT OF SPECIAL INSPECTIONS PER SECTION 1704 OF THE IBC. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSONWHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OFCONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. THESE INSPECTIONS ARE IN ADDITION TO THE INSPECTIONS SPECIFIED IN THEPROJECT SPECIFICATIONS.

2. SPECIAL INSPECTORS SHALL KEEP RECORDS OF INSPECTIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDINGOFFICIAL, AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. REPORTS SHALL INDICATE THAT WORK INSPECTED WASDONE IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OFTHE CONTRACTOR FOR CORRECTION. IF THE DISCREPANCIES ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THEATTENTION OF THE BUILDING OFFICIAL AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE PRIOR TO COMPLETION OFTHAT PHASE OF WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND CORRECTION OF ANY DISCREPANCIES NOTED INTHE INSPECTIONS SHALL BE SUBMITTED AT A POINT IN TIME AGREED UPON BY THE PERMIT APPLICANT AND THE BUILDING OFFICIAL PRIOR TO THESTART OF WORK.

3. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE SPECIAL INSPECTOR REGARDING INDIVIDUAL INSPECTION FOR ITEMS LISTED ON THESTATEMENT OF SPECIAL INSPECTIONS AND AS NOTED ON THE BUILDING DEPARTMENT APPROVED PLANS. ADEQUATE NOTICE AND ACCESS TOAPPROVED PLANS SHALL BE PROVIDED SO THAT THE SPECIAL INSPECTOR HAS TIME TO BECOME FAMILIAR WITH THE PROJECT.

4. FABRICATORS OF STRUCTURAL LOAD-BEARING MEMBERS AND ASSEMBLIES SHALL CONFORM TO THE REQUIREMENTS OF SECTION 1704.2 OF THEIBC.

STRUCTURAL OBSERVATION REQUIREMENTS (SAFE ROOM ONLY)

1. A REPRESENTATIVE OF THE ENGINEER OF RECORD WILL PERFORM THE VISUAL OBSERVATION OF THE STRUCTURAL SYSTEM FOR GENERALCONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS AT SIGNIFICANT CONSTRUCTION STAGES AND AT COMPLETION OF THESTRUCTURAL SYSTEM. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE INSPECTION REQUIRED OF THEBUILDING OFFICIAL OR THE SPECIAL INSPECTOR.

2. A PRE-CONSTRUCTION MEETING SHALL BE HELD AND ATTENDED BY THE ARCHITECT, ENGINEER OF RECORD, GENERAL CONTRACTOR,SUBCONTRACTORS, AND SPECIAL INSPECTORS.

3. THE GENERAL CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD (or name of other registered design professional or firm employed by the owner) ATLEAST 48 HOURS PRIOR TO COMPLETING CONSTRUCTION OPERATIONS THAT REQUIRE STRUCTURAL OBSERVATION (BY CALLING (918) 584-5858 TOSCHEDULE A SITE VISIT.)

4. AT A MINIMUM, THE FOLLOWING SIGNIFICANT CONSTRUCTION STAGES REQUIRE A SITE VISIT AND AN OBSERVATION REPORT FROM THESTRUCTURAL OBSERVER:A. AFTER INSTALLATION OF FIRST FOUNDATION REINFORCING AND BEFORE CONCRETE PLACEMENT.B. AFTER ERECTION OF FIRST LIFT OF CMU WALL AND BEFORE GROUT PLACEMENT.C. AFTER INSTALLATION OF CONCRETE ROOF REINFORCING AND BEFORE CONCRETE PLACEMENT.

ABBREVIATIONSKSI KIPS PER SQUARE INCHL LENGTHL.F.H. LONG FACE HORIZONTALLBS. POUNDSLG. LONGLL LIVE LOADLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLONG. LONGITUDINALMAX. MAXIMUMMCJ MASONRY CONTROL JOINTMECH. MECHANICALMFR. MANUFACTURERMIN. MINIMUMMISC. MISCELLANEOUSMTL. METALN.I.C. NOT IN CONTRACTN.S. NEAR SIDEN.T.S. NOT TO SCALENO. NUMBERO.C. ON CENTERO.D. OUTSIDE DIAMETERO.H. OPPOSITE HANDP.A.F. POWER ACTUATED FASTENERPCF POUNDS PER CUBIC FOOTPL PLATEPLF POUNDS PER LINEAR FOOTPMEJ PREMOLDED EXPANSION JOINTPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHQTY. QUANTITYR.O. ROUGH OPENINGRE: REFERREINF. REINFORCINGREQD. REQUIREDRTU ROOF TOP UNITS.D.S. SELF-DRILLING SCREWSSCHED. SCHEDULESIM. SIMILARSJI STEEL JOIST INSTITUTESPECS. SPECIFICATIONSSTD. STANDARDSTL. STEELT THICKT&B TOP AND BOTTOMT.O. TOP OFT.O.C. TOP OF CONCRETET.O.P. TOP OF PIERT.O.W. TOP OF WALLTL TOTAL LOADTRANS. TRANSVERSETYP. TYPICALU.N.O. UNLESS NOTED OTHERWISEVERT. VERTICALW WIDEW.P. WORK POINTW.W.F. WELDED WIRE FABRICWT. WEIGHT

ABBREVIATIONS

A.B. ANCHOR BOLTSA.F.F. ABOVE FINISHED FLOORACI AMERICAN CONCRETE INSTITUTEADJ. ADJUSTAESS ARCHITECTURALLY EXPOSED

STRUCTURAL STEELARCH. ARCHITECTURALB.L. BLOCK LINTELB.O. BOTTOM OFB.O.D. BOTTOM OF DECKBAL. BALANCEBLDG. BUILDINGBOT. BOTTOMBRG. BEARINGC.J. CONTRACTION JOINTC.L. CENTER LINECFMF COLD FORMED METAL FRAMINGCLR. CLEARCMU CONCRETE MASONRY UNITCOL. COLUMNCONC. CONCRETECONST. CONSTRUCTIONCONT. CONTINUOUSD.B.A. DEFORMED BAR ANCHORDIA. DIAMETERDIAG. DIAGONALDTL. DETAILDWG. DRAWINGE.A. EACHE.F. EACH FACEE.J. EXPANSION JOINTE.O.D. EDGE OF DECKE.O.S. EDGE OF SLABE.W. EACH WAYELEC. ELECTRICALELEV. OR EL. ELEVATIONEQ. EQUALEXIST. EXISTINGF.F.E. FINISHED FLOOR ELEVATIONF.S. FAR SIDEFDN. FOUNDATIONFLR. FLOORFTG. FOOTINGG.B. GRADE BEAMG.C. GENERAL CONTRACTORGA. GAGEGALV. GALVANIZEDH HEIGHTH.S.A. HEADED STUD ANCHORHORIZ. HORIZONTALIBC INTERNATIONAL BUILDING CODEINFO. INFORMATIONJ.B.E. JOIST BEARING ELEVATIONJT. JOINTK UNIT OF 1,000 POUNDS (KIP)

STATEMENT OF SPECIAL INSPECTIONS (IBC 2009)

REQUIRED VERIFICATION AND INSPECTION TASKFREQUENCY OF INSPECTIONCONTINUOUS PERIODIC

I. STEEL CONSTRUCTION (IBC TABLE 1704.3)

1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS AND WASHERS:A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED

CONSTRUCTION DOCUMENTS.--- X

B. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. --- X2. INSPECTION OF HIGH STRENGTH BOLTING:

A. SNUG-TIGHT JOINT. --- XB. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITH MATCHMARKING, TWIST-OFF BOLT

OR DIRECT TENSION INDICATOR METHODS OF INSTALLATION.--- X

C. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITHOUT MATCHMARKING ORCALIBRATED WRENCH METHODS OF INSTALLATION.

X ---

3. MATERIAL VERIFICATION OF STRUCTURAL STEEL AND COLD-FORMED STEEL DECK:A. FOR STRUCTURAL STEEL, IDENTIFICATION MARKINGS TO CONFORM TO AISC 360. --- XB. FOR OTHER STEEL, IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE

APPROVED CONSTRUCTION DOCUMENTS.--- X

C. MANUFACTURER'S CERTIFIED TEST REPORTS. --- X4. MATERIAL VERIFICATION OF WELD FILLER MATERIALS:

A. IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION IN THE APPROVED CONSTRUCTIONDOCUMENTS.

--- X

B. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. --- X5. INSPECTION OF WELDING:

A. STRUCTURAL STEEL AND COLD-FORMED STEEL DECK: --- ---1) COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS. X ---2) MULTIPASS FILLET WELDS. X ---3) SINGLE-PASS FILLET WELDS > 5/16" X ---4) PLUG AND SLOT WELDS. X ---5) SINGLE-PASS FILLET WELDS < OR = 5/16" --- X6) FLOOR AND ROOF DECK WELDS. --- X

B. REINFORCING STEEL: --- ---1) VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM A 706 --- X2) SHEAR REINFORCEMENT X ---3) OTHER REINFORCING STEEL. --- X

6. INSPECTION OF STEEL FRAME JOINT DETAILS FOR COMPLIANCEA. DETAILS SUCH AS BRACING AND STIFFENING. --- XB. MEMBER LOCATIONS. --- XC. APPLICATION OF JOINT DETAILS AT EACH CONNECTION. --- X

II. CONCRETE CONSTRUCTION (IBC TABLE 1704.4)

1. INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT. --- X2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE 1704.3, ITEM 5B. --- ---3. INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING PLACEMENT OF CONCRETE

WHERE ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE STRENGTH DESIGN IS USED.X ---

4. INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE. --- X5. VERIFYING USE OF REQUIRED DESIGN MIX. --- X6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM

SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE.X ---

7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. X ---8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. --- X9. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST TENSIONED

CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS.--- X

10. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEINGFORMED.

--- X

III. MASONRY CONSTRUCTION - LEVEL 1 (IBC TABLE 1704.5.1)

1. COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND THEAPPROVED SUBMITTALS SHALL BE VERIFIED.

--- X

2. VERIFICATION OF f'm AND f'aac PRIOR TO CONSTRUCTION EXCEPT WHERE SPECIFICALLY EXEMPTED BYTHIS CODE.

--- X

3. VERIFICATION OF SLUMP FLOW AND VSI AS DELIVERED TO THE SITE FOR SELF-CONSOLIDATION GROUT. X --4. AS MASONRY CONSTRUCTION BEGINS, THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE:

A. PROPORTIONS OF SITE-PREPARED MORTAR. --- XB. CONSTRUCTION OF MORTAR JOINTS. --- XC. LOCATION OF REINFORCEMENT, CONNECTORS, PRESTRESSING TENDONS AND ANCHORAGES. --- X

5. DURING CONSTRUCTION THE INSPECTION PROGRAM SHALL VERIFY:A. SIZE AND LOCATION OF STRUCTURAL ELEMENTS. --- XB. TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO

STRUCTURAL MEMBERS, FRAMES OR OTHER CONSTRUCTION.--- X

C. SPECIFIED SIZE, GRADE AND TYPE OF REINFORCEMENT, ANCHOR BOLTS, PRESTRESSING TENDONS ANDANCHORAGES.

--- X

D. WELDING OF REINFORCING BARS. X ---E. PREPARATION, CONSTRUCTION AND PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURE

BELOW 40 DEG. F) OR HOT WEATHER (TEMPERATURE ABOVE 90 DEG. F.)--- X

6. PRIOR TO GROUTING, THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE:A. GROUT SPACE IS CLEAN --- XB. PLACEMENT OF REINFORCEMENT, CONNECTORS, PRESTRESSING TENDONS AND ANCHORAGES. --- XC. PROPORTIONS OF SITE-PREPARED GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS. --- XD. CONSTRUCTION OF MORTAR JOINTS. --- X

7. GROUT PLACEMENT SHALL BE VERIFIED TO ENSURE COMPLIANCE. X ---8. PREPARATION OF ANY REQUIRED GROUT SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS SHALL BE

OBSERVED.-- X

V. REQUIRED VERIFICATION AND INSPECTION OF SOILS (IBC TABLE 1704.7)

1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARINGCAPACITY.

--- X

2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. --- X3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. --- X4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND

COMPACTION OF COMPACTED FILL.X ---

5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEENPREPARED PROPERLY.

--- X

113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
113665
Text Box
ANYTOWN
113665
Text Box
ANYTOWN, OK. 00000
Page 9: S:Projectsa6 Cordell PS - New Classroom Bldg03 … School - Submittal... · ctr center ctsk countersink ... dwg/dwg's drawing/drawings e east ea each ej expansion joint ... fa fire

FINISH FLOOR0"

FIELD HOUSEPARAPET

16' - 0"

24' - 11 1/4"

F1 F7F2 F3 F4 F5 F6 F6.9 F8F7.4 F7.8 F8.1 F9 F10 F10.9 F11F3.9F2.1

SPLIT FACE CMU MASONRY

BRICK ROWLOCK WATERTABLE

MASONRY VENEER

EXTERIOR ARCHITECTURALLIGHT FIXTURE TYP. REFERELECTRICAL

EIFS BAND

EIFS VENEER

ROOF OVERFLOW SCUPPER

PRE-FINISHED METALPARAPET CAP FLASHING

16' -

0"

4"

1'-0"

PRE-FINISHED SHEETMETAL GUTTER ANDDOWNSPOUT

STANDING SEAMMETAL ROOF

PRE-FINISHED METALFASCIA TRIM

EXTERIOR LEDALUMINUM SIGNAGE

111.3G

4' -

8"1'

- 4"

7' -

0"3'

- 0"SPLIT FACE CMU MASONRY

BRICK ROWLOCK WATERTABLEMASONRY VENEER

EXTERIOR ARCHITECTURALLIGHT FIXTURE TYP. REFER

ELECTRICAL

EIFS BAND

EIFS VENEER

ROOF OVERFLOW SCUPPER

PRE-FINISHED METALPARAPET CAP FLASHING

4' -

8"1'

- 4"

10' -

0"

8' -

11 1

/4"

16' -

0"24

' - 1

1 1/

4"

PRE-MANUFACTURED ALUMINUM AWNING

CJCJCJCJCJCJCJCJCJCJCJCJCJCJCJCJCJCJCJ

7' -

0"3'

- 0"

10' -

0"

4' -

8"1'

- 4"

7' -

0"3'

- 0"

16' -

0"

FINISH FLOOR0"

FIELD HOUSEPARAPET

16' - 0"

F1F7 F2F3F4F5F6F6.9F8 F7.4F7.8F8.1F9F10F10.9F11 F3.9 F2.1

24' - 11 1/4"

SPLIT FACE CMU MASONRYBRICK ROWLOCK WATERTABLE

MASONRY VENEER

EXTERIOR ARCHITECTURALLIGHT FIXTURE TYP. REFER

ELECTRICAL

EIFS BAND

EIFS VENEER

PRE-FINISHED METALPARAPET CAP FLASHING

PRE-FINISHED SHEETMETAL GUTTER AND

DOWNSPOUT

STANDING SEAMMETAL ROOF

PRE-FINISHED METALFASCIA TRIM

EXTERIOR LIGHTINGREFER ELECTRICAL

SPLIT FACE CMU MASONRY

BRICK ROWLOCK WATERTABLEMASONRY VENEER

PRE-MANUFACTUREDALUMINUM AWNING

EXTERIOR ARCHITECTURAL LIGHTFIXTURE TYP. REFER ELECTRICAL

EIFS BAND

EIFS VENEER

PRE-FINISHED METALPARAPET CAP FLASHING

205.1 206.1 204.1 000.1111.1 108.1H A A

STEEL TRUSS REFERSTRUCTURAL

CJCJCJCJCJCJCJCJCJCJCJCJCJCJCJCJCJ

EWC

3' -

0"4'

- 8"

2' -

4"

2' -

10 5

/8"

7' -

1 3/

8"1'

- 4"

4' -

8"

10' -

0"

6' -

0"

16' -

0"

ADA ADA

FINISH FLOOR0"

FIELD HOUSEPARAPET

16' - 0"

FC FBFD

SPLIT FACE CMU MASONRY

BRICK ROWLOCK WATERTABLEMASONRY VENEER

EXTERIOR ARCHITECTURAL LIGHTFIXTURE TYP. REFER ELECTRICAL

EIFS BAND

EIFS VENEER

PRE-FINISHED METALPARAPET CAP FLASHING

PRE-FINISHED SHEET METALGUTTER AND DOWNSPOUT

STANDING SEAMMETAL ROOF

4' -

8"1'

- 4"

7' -

1 3/

8"2'

- 10

5/8

"

8' -

11 1

/4"

16' -

0"24

' - 1

1 1/

4"

FA

CJCJ

CJ CJ CJ CJ CJ CJ CJ

FINISH FLOOR0"

FIELD HOUSEPARAPET

16' - 0"

FCFB FD

SPLIT FACE CMU MASONRY

BRICK ROWLOCK WATERTABLEMASONRY VENEER

EXTERIOR ARCHITECTURAL LIGHTFIXTURE TYP. REFER ELECTRICAL

EIFS BAND

EIFS VENEER

PRE-FINISHED METALPARAPET CAP FLASHING

PRE-FINISHED SHEET METALGUTTER AND DOWNSPOUT

STANDING SEAMMETAL ROOF

4' -

8"1'

- 4"

10' -

0"

8' -

11 1

/4"

16' -

0" 24

' - 1

1 1/

4"

100.1

PRE-MANUFACTUREDALUMINUM AWNING

FA

CJCJCJCJCJCJCJ

8' -

0" ADA

FINISH FLOOR0"

TICKET BOOTHEAVE

10' - 0"

F7.4F7.8 5AF-300

000.1

SPLIT FACE CMU MASONRY

BRICK ROWLOCK WATERTABLE

MASONRY VENEER

Level 10' - 0"

Level 210' - 0"

Level 10' - 0"

Level 210' - 0"

PROJECT ALTERNATES: ALL ALTERNATES ACCEPTED

ALTERNATE #1 (FIELD HOUSE):ALTERNATE #1 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TOCONSTRUCT:2) 8'x78' BREEZEWAY ON NORTH SIDE OF BUILDING3) FIVE MASONRY COLUMNS4) 8'x115' TPO ROOFING SYSTEM5) 8'x30' STANDING SEAM METAL ROOF

ALTERNATE #2 (STEM BUILDING):ALTERNATE #2 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TOCONSTRUCT:1) NORTH VESTIBULE

ALTERNATE #3 (STEM BUILDING):ALTERNATE #3 - DEDUCT ALTERNATECONSISTS OF ALL MATERIALS AND LABOR NECESSARY TOCONSTRUCT:1) SOUTH VESTIBULE5' - 3 3/4" 22' - 10 5/8" 5' - 3 3/4"

5' -

0"1'

- 5"

17".

20".

EXTERIOR CHANNEL LETTERS WITHINTERAL ILLUMINATION REFER SPECS

EXTERIOR CHANNEL SCHOOL LOGO WITHINTERAL ILLUMINATION REFER SPECS

9' - 5"

CL

SHEET NO.:

SHEET TITLE:

PROJECT NO.:

DATE:

CHECKED BY:

PROJ. MANAGER:

DRAWN BY:BWEEKS

BWEEKS

PARTNERSHIP

ARCHITECTSIN

SEAL:

ARCHITECTSINTERIOR DESIGNERSPLANNERS

3220 MARSHALL AVENUENORMAN, OK 73072TEL: 405.360.1300FAX: 405.360.1431

KEYPLAN:

JHOWARD

CO

RD

ELL

PUB

LIC

SC

HO

OLS

2014

BO

ND

- FI

ELD

HO

USE

606

E. T

HIR

D S

TREE

T, C

OR

DEL

L, O

K 73

632

1416

AF-200

MAY 11, 2015

BUILDINGELEVATIONS

SCALE: 1/8" = 1'-0"AF-200REF. TO SHT.:AF-100

1 SOUTH ELEVATION

SCALE: 1/8" = 1'-0"AF-200REF. TO SHT.:AF-100

2 NORTH ELEVATION

SCALE: 1/8" = 1'-0"AF-200REF. TO SHT.:AF-100

3 EAST ELEVATIONSCALE: 1/8" = 1'-0"AF-200REF. TO SHT.:AF-100

4 WEST ELEVATION

SCALE: 1/4" = 1'-0"AF-200REF. TO SHT.:AF-102

5 TICKET BOOTH EASTSCALE: 1/4" = 1'-0"AF-200REF. TO SHT.:AF-110

6 EXTERIOR SIGNAGE - SOUTH ELEVATION

REVISIONSREV DATE DESCRIPTION

1 06/03/2015 FIREMARSHALLREVISIONS