SOUTHWIRE’S MCAP®

Southwire's patented innovation will save contractors up to 30 percent ininstallation time and costs. This UL-listed and NEC compliant product replacesconventional MC cable in a broad range of applications because it eliminates theneed to make-up a ground in every box, in every outlet, every time. With its

superior bending and pulling performance, MCAP® assures a professional lookinginstallation in fewer steps, with less labor and in less time. It's another Southwire

innovation to help gain a competitive edge on every job.

MCAP®, the next generation in metal clad cable.

Page 3: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS USEDÛ For certain applications:

- For branch, feeder, power, lighting, control, signal circuits and service power distribution in commercial,industrial, institutional and multi-residential buildings- Fished or embedded in plaster- For cable trays and approved raceways

Û For certain locations:- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For concealed or exposed installations

Armorlite®ACALUMINUM ARMORED CABLE

HOW ITÊS MADEÛ Conductors: Type THHN/THWN, soft-drawn copper, wrapped with a moisture-resistant, flame-retardant paper

covering and then aluminum armor is applied over the conductorsÛ A 16 AWG aluminum bond wire is placed inside the armor and runs longitudinally

HOW ITÊS CERTIFIEDÛ SouthwireÊs Armorlite® Type AC meets or exceeds the requirements of UL Standard 4 for Armored Cable,

UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code.SouthwireÊs Armorlite® Type AC is listed for use in UL 1, 2 and 3 Hour Through-Penetration Firestop Systems.

54

Û AC: Aluminum CableÛ 600 VoltsÛ For Dry Locations

Page 4: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

Arm

orlit

e®A

CA

LUM

INU

MA

RMO

RED

CA

BLE

55

CONDUCTORSIZE

(AWG)CONDUCTOR

TYPE

ALUMINUMBONDINGWIRE SIZE

(AWG)OUTSIDE

DIAMETER(INCHES)

ALUMINUM INTERLOCKED ARMOR AMPACITIES+ (AMPS)

WEIGHT(LBS./1000 FT.) 60■C 75■C 90■C

14/214/314/412/212/312/410/210/310/48/28/38/46/26/36/44/34/43/33/42/32/4

SOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLID

STRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDED

16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID

.464

.484

.517

.498

.521

.557

.560

.588

.632

.686

.749

.810

.783

.827

.8961.0951.1501.1751.2441.1901.310

8610512610713416314218422821131138731842453562579774610038981155

151515202020303030404040555555707085859595

1515152020203030305050506565658585100100115115

1515152020203030305555557575759595110110130130

WEIGHTS AND MEASUREMENTS

234

STANDARD COLOR 120/208Y SPECIAL COLOR 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

# OF CONDUCTORS

Grounding Conductor is Green.

14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 10/4 8/2 8/3 8/4 6/2 6/3 6/4 4/3 4/4 3/3 3/4 2/42/3250 FTCOIL

1000 FTREEL

+Ampacities are based on Table 310.16 of the NEC, 2005 Edition. +Allowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, Section 310.15. If the equipment is marked for use at highertemperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C).60■C - When terminated to equipment for circuits rated 100 amperes or less or marked for size 14 through 1 AWG conductors.75■C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG.90■C - For ampacity derating purposes.Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor.

PACKAGING

COLOR CODING

Page 5: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS USEDÛ For certain applications:

- For branch, feeder, power, lighting, control, signal circuits and service power distribution in commercial,industrial, institutional and multi-residential buildings- Fished or embedded in plaster- For cable trays and approved raceways

Û For certain locations:- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For concealed or exposed installations

Duraclad®ACSTEEL ARMORED CABLE

HOW ITÊS MADEÛ Conductors: Type ACTHH (THHN/THWN-singles), soft-drawn copper, wrapped with a moisture-resistant,

flame-retardant paper covering and then aluminum armor is applied over the conductorsÛ A 16 AWG aluminum bond wire is placed inside the armor and runs longitudinally

HOW ITÊS CERTIFIEDÛ SouthwireÊs Duraclad® Type AC Cable meets or exceeds the requirements of UL Standard 4 for Armored Cable,

UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code.SouthwireÊs Duraclad® Type AC is listed for use in UL 1, 2 and 3 Hour Through-Penetration Firestop Systems.

HOW ITÊS DEFINEDÛ An armor assembly (combination of the interlocked armor & bonding strip) that is recognized as an equipment

grounding conductor per NEC 250.118(8)Û Reduces installation costs up to 50% over pipe and wireÛ UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113,

W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173,C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038

Û Anti-short/insulating bushings supplied with every reel or coilÛ When pulling from coils, pull from inside to ensure proper installation - For easier installation and pulling,

cable reverse

56

Û AC: Aluminum CableÛ 600 VoltsÛ For Dry Locations Only

Page 6: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

Dur

acl

ad

®A

CST

EEL

ARM

ORE

DC

ABL

E

57

CONDUCTORSIZE

(AWG)CONDUCTOR

TYPE

ALUMINUMBONDINGWIRE SIZE

(AWG)OUTSIDE

DIAMETER(INCHES)

ALUMINUM INTERLOCKED ARMOR AMPACITIES+ (AMPS)

WEIGHT(LBS./1000 FT.) 60■C 75■C 90■C

14/214/314/412/212/312/410/210/310/48/28/38/46/26/36/44/34/42/32/4

SOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLID

STRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDED

16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID

.490

.520

.530

.520

.550

.575

.580

.615

.655

.695

.825

.850

.880

.870

.9501.1601.1401.3101.632

192219241217251290270314380354605678619739888976123111701555

15151520202030303040404055555570709595

1515152020203030305050506565658585115115

1515152020203030305555557575759595130130

WEIGHTS AND MEASUREMENTS

COLOR CODING

234

STANDARD COLOR 120/208Y SPECIAL COLOR 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

# OF CONDUCTORS

Grounding Conductor is Green.

14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 10/4 8/2 8/3 8/4 6/2 6/3 6/4 4/3 4/4 3/3 3/4 2/42/3250 FTCOIL

1000 FTREEL

Note: Ampacities are based on Table 310.16 of the NEC, 2005 Edition.+Allowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, Section 310.15.If the equipment is marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C).60■C - When terminated to equipment for circuits rated 100 amperes or less or marked for size 14 through 1 AWG conductors.75■C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG.90■C - For ampacity derating purposes.Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor.

PACKAGING

Page 7: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Conductors: Type ACTHH (THHN/THWN-singles), soft-drawn copper, wrapped with a moisture-resistant,

flame-retardant paper covering, then lightweight, steel interlocking armor is applied over the conductors andhas a green insulated copper grounding conductor

Û A 16 AWG aluminum bond wire is placed inside the armor

HOW ITÊS CERTIFIEDÛ SouthwireÊs Duraclad® Type AC HCF meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL

Standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. SouthwireÊsDuraclad® Type AC HCF is listed for use in UL 1, 2 and 3 Hour Through-PenetrationFirestop Systems.

58

Û AC: Aluminum CableÛ HCF: Hospital CareFacility

Û 600 VoltsÛ For Dry Locations

HOW ITÊS USEDÛ For certain applications:

- For branch, feeder, power, lighting, control, signal circuits and service power distribution in commercial,industrial, institutional and multi-residential buildings

- For branch-circuit wiring, electrical systems in patient care areas of hospitals, nursing homes, dental offices,outpatient facilities and other medical or health related facilities- Fished or embedded in plaster- For cable trays and approved raceways

Û For certain locations:- For Dry Locations only- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For concealed or exposed installations- For hazardous anesthetizing areas and essential electrical system circuits are prohibited, except aspermitted, per 2005 NEC 517.30(C)(3)(3)

Duraclad®AC HCFSTEEL ARMORED CABLE

HOW ITÊS DEFINEDÛ An armor assembly (combination of the interlocked armor & bonding strip) that is recognized as an equipment

grounding conductor per 2005 NEC Articles 250.118(8) and 517.30(A)Û An insulated equipment grounding conductor per NEC 517.13(B) and Table 250.122Û Reduces installation costs up to 50% over pipe and wireÛ UL Classified 1, 2 and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113,

W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173,C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038

Û Anti-short/insulating bushings supplied with every reel or coilÛ When pulling from coils, pull from inside to ensure proper installation. For easier installation and pulling,

cable reverse wound on reel.

Page 8: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

59

Dur

acl

ad

®A

CH

CFST

EEL

ARM

ORE

DC

ABL

E

PHASECONDUCTOR

SIZE(AWG)

CONDUCTORTYPE

ALUMINUMBONDING WIRE

SIZE(AWG)

OUTSIDEDIAMETER(INCHES)

AMPACITIES+ (AMPS)STEEL INTERLOCKED ARMOR

WEIGHT(LBS./1000 FT.) 60■C 75■C 90■C

.520

.530

.570

.550

.575

.640

.615

.655

.725

224241294251291335314380449

151515202020303030

151515202020303030

151515202020303030

14/314/314/412/212/312/410/210/310/4

SOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLID

16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID16 SOLID

COLOR CODING

234

STANDARD COLOR 120/208Y SPECIAL COLOR 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

# OF CONDUCTORS

Grounding Conductor is Green.

12/214/2 14/3 14/4 12/3 12/4 10/2 10/3 10/4250 FTCOIL

1000 FTREEL

Note: Ampacities are based on Table 310.16 of the NEC, 2005 Edition.+Allowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, Section 310.15.If the equipment is marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C).60■C - When terminated to equipment for circuits rated 100 amperes or less or marked for size 14 through 1 AWG conductors.75■C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG.90■C - For ampacity derating purposes.Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor.

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 9: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS USEDÛ For certain applications:

- For branch, feeder, power, lighting, control, signal circuits and service power distribution in commercial,industrial, institutional and multi-residential buildings- For aerial cable on a messenger- For cable trays and approved raceways

Û For certain locations:- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- For concealed or exposed installations- Hazardous locations: Class 1 Div. 2, Class 2 Div. 2, and Class 3 Div.1

Armorlite®MCALUMINUM ARMORED CABLE

HOW ITÊS MADEÛ Conductors: Type THHN/THWN, soft-drawn copper that is available in sizes 14 AWG through 750 kcmil and is

rated 90■C dry/75■C wetÛ Has a green insulated grounding conductor until size is 1/0 AWG and larger, then it has a bare grounding conductorÛ Cables are combined using binder tape and an aluminum interlocking armor is placed over the cables

HOW ITÊS CERTIFIEDÛ SouthwireÊs Armorlite® Type MC meets or exceeds the requirements of UL Standard 83, UL Standard 1063,

UL Standard 1569 for Type MC, Federal Specification A-A59544 (formerly J-C-30B), IEEE 1202 (70,000 Btu/hr)Vertical Cable Tray Flame Test and the National Electrical Code. SouthwireÊs Armorlite® Type MC is listed foruse in UL 1, 2 and 3 Hour Through Penetration Firestop Systems.

60

Û MC: Metal CladÛ 600 VoltsÛ For Wet and Dry LocationsÛ 90■C Heat Capacity

Page 10: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

Arm

orlit

e®M

CA

LUM

INU

MA

RMO

RED

CA

BLE

61

CONDUCTORSIZE*(AWG)

CONDUCTORTYPE

GROUNDINGCONDUCTORSIZE (AWG)

AND STRANDING

OVERALLDIAMETER(INCHES)

WEIGHT(lbs./1000 ft.) 60■C 75■C 90■C

AMPACITIES+

14/214/314/412/212/312/312/312/412/410/210/210/310/310/410/48/28/38/4

SOLIDSOLIDSOLID

19SOLID

19SOLID

19SOLID

19SOLID

19SOLID

19SOLID

191919

14 SOLID14 SOLID14 SOLID

12-1912 SOLID

12-1912 SOLID

12-1912 SOLID

10-1910 SOLID

10-1910 SOLID

10-1910 SOLID

10-1910-1910-19

.439

.464

.494

.494

.475

.527

.505564.539.566.542.607.58.653.623.678.678.732

7794112110104137129164155159150201189243229234298370

151515202020202020303030303030404040

151515202020202020303030303030505050

151515202020202020303030303030555555

14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 10/4 8/2 8/3100 FTCOIL

125 FTCOIL

200 FTCOIL

250 FTCOIL

500 FTREEL

750 FTREEL

1000 FTREEL

234

STANDARD COLORS 120/208Y OPTIONAL COLORS 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

# OF CONDUCTORS

Grounding Conductor is Green.+Ampacities are based on Table 310.16 of the NEC, 2005 Edition. +Allowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, Section 310.15. If the equipment ismarked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C). 60■C - When terminated to equipment for circuits rated 100 amperes or less or marked for size14 through 1 AWG conductors. 75■C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90■C - For ampacity derating purposes.Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor. * Available in sizes up to 750 kcmil.

WEIGHTS AND MEASUREMENTS

PACKAGING

COLOR CODING

Page 11: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS USEDÛ For certain applications:

- For branch, feeder, power, lighting, control, signal circuits and service power distribution in commercial,industrial, institutional and multi-residential buildings

- For aerial cable on a messenger- For cable trays and approved raceways

Û For certain locations:- For concealed or exposed installations- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- For concealed or exposed installations- Hazardous locations: Class 1 Div. 2, Class 2 Div. 2, and Class 3 Div.1

Duraclad®MCSTEEL ARMORED CABLE

HOW ITÊS MADEÛ Conductors: Type THHN/THWN (insulated singles), soft-drawn copper that is available in sizes 14 AWG through

750 kcmil and is rated 90■C dry/75■C wetÛ Has a green insulated grounding conductor until size is 1/0 AWG and larger, then it has a bare grounding conductorÛ Cables are combined using binder tape and an aluminum interlocking armor is placed over the cables

HOW ITÊS CERTIFIEDÛ SouthwireÊs Duraclad® Type MC meets or exceeds the requirements of UL Standard 83, UL Standard 1063,

UL Standard 1569 for Type MC, Federal Specification A-A59544 (formerly J-C-30B), IEEE 1202 (70,000 Btu/hr)Vertical Cable Tray Flame Test and the National Electrical Code. SouthwireÊs Duraclad® Type MC is listed for usein UL 1, 2 and 3 Hour Through-Penetration Firestop Systems.

62

Û MC: Metal CladÛ 600 VoltsÛ For Wet and Dry

LocationsÛ 90■C Heat Capacity

Page 12: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

Dur

acl

ad

®M

CST

EEL

ARM

ORE

DC

ABL

E

63

CONDUCTORSIZE +(AWG)

CONDUCTORTYPE

GROUNDINGCONDUCTORSIZE (AWG)

OVERALLDIAMETER(INCHES)

WEIGHT(LBS./1000 FT.) 60■C 75■C 90■C

AMPACITIES+

14/214/314/412/212/312/410/210/310/4

SOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLID

141414121212101010

0.4470.4720.5020.4750.5130.5470.5500.5880.631

115134155142172201197240284

151515202020303030

151515202020303030

151515202020303030

14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 10/4250 FTCOIL

1000 FTREEL

234

STANDARD COLORS 120/208Y OPTIONAL COLORS 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

# OF CONDUCTORS

Grounding Conductor is Green.+Ampacities are based on Table 310.16 of the NEC, 2005 Edition. ÚAllowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, Section 310.15. If the equipment ismarked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C). 60■C - When terminated to equipment for circuits rated 100 amperes or less or marked for size14 through 1 AWG conductors. 75■C - When terminated to equipment for circuits rated over 100 amperes or marked for cÚAllowable ampacities shown are for general use as specified by the National ElectricalCode, 2005 Edition, Section 310.15. If the equipment is marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C). 60■C - When terminated to equipmentfor circuits rated 100 amperes or less or marked for size 14 through 1 AWG conductors. 75■C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG.90■C - For ampacity derating purposes. Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor. *Circuit sizes 12 AWGand 10 AWG also available as stranded conductors.onductors larger than size 1 AWG. 90■C - For ampacity derating purposes. Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of0.80 when the neutral is considered a current-carrying conductor. + Available in sizes up to 750 kcmil.

WEIGHTS AND MEASUREMENTS

PACKAGING

COLOR CODING

Page 13: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Conductors: Type THHN/THWN, soft-drawn copper, has a green insulated grounding conductor and is rated

90■C dry/75■C wetÛ Cables are combined using binder tape and an aluminum interlocking armor is placed over the cablesÛ Black, flame-retardant PVC jacket is applied over the armor and is available in blue or grey, colors requested

subject to economic order quantities

HOW ITÊS DEFINEDÛ Reduces installation costs up to 50% over pipe and wireÛ Lightweight aluminum armor as much as 45% lighter than steel MC CableÛ UL Classified 1, 2 and 3 Hour Through-Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113,

W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173,C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038

HOW ITÊS CERTIFIEDÛ SouthwireÊs Armorlite® Feeder Type MC Cable (PVC Jacketed) meets or exceeds the requirements of UL

Standard 83, UL Standard 1063, UL Standard 1569 for Type MC, Federal Specification A-A59544(formerly J-C-30B), IEEE 1202 (70,000 BTU/hr) Vertical Cable Tray Flame Test and the National Electrical Code.SouthwireÊs Armorlite® Feeder Type MC (PVC Jacketed) is listed for use in UL Standard 1479 1, 2 and 3 HourThrough-Penetration Firestop Systems.

64

Û MC: Metal CladÛ 600 VoltsÛ Copper Power FeederConductors

HOW ITÊS USEDÛ For certain applications:

- For branch, feeder, power, lighting, control, signal circuits and service power distribution in commercial,industrial, institutional and multi-residential buildings

- Fished or embedded in plaster- For aerial cable on a messenger- For cable trays and approved raceways

Û For certain locations:- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- For concealed or exposed installations- Hazardous locations: Class 1 Div. 2, Class 2 Div. 2 and Class 3 Div. 1

Armorlite® Feeder MCALUMINUM ARMORED CABLE

?DID YOU KNOWSouthwireÊs Feeder MC was used inthe construction of Las VegasÊ veryown Wynn Resort and Casino.

Page 14: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

1-BLACK, 2-RED, 3-BLUE, WHITE1-BLACK, 2-RED, WHITE

65

CONDUCTOR SIZE/# OF COND.(AWG/kcmil)

GROUNDINGCONDUCTOR

(AWG)†

APPROXIMATEDIAMETER

OVER ARMOR(INCHES)

APPROXIMATEDIAMETER

OVER JACKET(INCHES)

AMPACITY+ (AMPS)

1/31/4

1/0-31/0-42/0-32/0-43/0-33/0-44/0-34/0-4250-3250-4350-3350-4500-3500-4600-3600-4750-3750-4

6 Green6 Green6 Bare6 Bare6 Bare6 Bare4 Bare4 Bare4 Bare4 Bare4 Bare4 Bare3 Bare3 Bare2 Bare2 Bare2 Bare2 Bare1 Bare1 Bare

1.2031.3511.2451.3621.3391.4911.4491.6141.5701.7491.7371.9131.9602.1622.2382.4772.4692.7142.6742.960

1.3034.4511.3421.4621.4391.5911.5491.7341.6901.8691.8572.0332.0802.2822.3582.6272.6192.8822.8243.110

1252158514631863175823322175289426623507317840864252549358297642707892818537

11,111

130130150150175175200200230230255255310310380380420420475475

150150170170195195225225260260290290350350430430475475535535

Arm

orlite®

Feed

erMC

ALU

MIN

UM

ARM

ORE

DC

ABL

E34

COLOR SEQUENCE 120/208Y*# OF CONDUCTORS

Grounding Conductor is Bare.

75■C 90■CWEIGHT

(LBS./1000 FT.)

Note: Ampacities are based on Table 310.16 of the NEC, 2005 Edition.+Allowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, Section 310.15.If the equipment is marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C).75■C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG.90■C - For ampacity derating purposes.Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor.Available with oversized grounding conductor when used for parallel feeds on special orders.

*Color sequence for 277V/480V systems and other special colors are available subject to economic order quantity.Note: Phase conductors are black with printed ID.

WEIGHTS AND MEASUREMENTS

COLOR CODING*

Page 15: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Conductors: Type THHN/THWN, solid soft-drawn copper that is available in sizes 14 AWG – 10 AWG, has a bare

aluminum, grounding conductor and is rated 90■C dryÛ Cables are combined using binder tape and a lightweight aluminum interlocking armor is placed over the cablesÛ The bare aluminum, grounding conductor is located outside of the binding tape and has the same lay as the

insulated conductors.

HOW ITÊS DEFINEDÛ An armor assembly that is an equipment grounding conductor per 2005 NEC 250.118(10)(a)Û Installation instructions included with every reel and coil.Û Simplified product application and installation compared to other armored productsÛ Faster conductor make-up, wiring device installation and trim-out when grounding/bonding conductor is

terminated per installation instructionsÛ Reduces installation costs up to 50% over pipe and wireÛ UL Classified 1, 2 and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117,

W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065,C-AJ-4066, F-C-3038

Û When pulling from coils, pull from inside to ensure ease of installation. For easier installation and pulling,cable is reverse wound on reel.

HOW ITÊS CERTIFIEDÛ SouthwireÊs Armorlite Type MCAP™ meets or exceeds the applicable requirements of UL 1569 Standard for Metal-Clad

Cables, NFPA 70 National Electrical Code, UL 83 Standard, UL 1063 Standard, Federal Specification A-A59544(formerly J-C-30B) and IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test. SouthwireÊs Armorlite Type MCAP™

is listed for use in UL 1, 2 and 3 Hour Through-Penetration Firestop Systems.

66

Û MCAP: Metal-CladAll-Purpose

Û 600 Volts

HOW ITÊS USEDÛ For certain applications:

- For branch, feeder, power, lighting, control, signal circuits and service power distribution in commercial,industrial, institutional and multi-residential buildings- Fished or embedded in plaster- For cable trays and approved raceways

Û For certain locations:- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- For concealed or exposed installations- For areas where standard AC or MC cable is permitted

MCAP ®

ALL-PURPOSE METAL CLAD

EquipmentGroundingConductor

Page 16: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

67

CONDUCTORSIZE (AWG) / #

OF PHASECONDUCTORS

CONDUCTORTYPE

GROUNDING/BONDING

CONDUCTOR

OVERALLDIAMETER(INCHES)

WEIGHT(LBS./1000FT.)

AMPACITY (AMPS)

14/214/314/412/212/312/410/210/3

SOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLIDSOLID

12 SOLID AL12 SOLID AL12 SOLID AL10 SOLID AL10 SOLID AL10 SOLID AL8 SOLID AL8 SOLID AL

0.3850.4100.4350.4300.4450.4800.4850.520

63789688110134123162

1515152020203030

1515152020203030

1515152020203030

MCA

ALL

-PU

RPO

SEM

ETA

LC

LAD2

34

STANDARD COLORS 120/208Y OPTIONAL COLORS 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

# OF CONDUCTORS

Grounding Conductor is Green.

60■C 75■C 90■C

14/414/2 14/3 12/2 12/3 12/4 10/2 10/3250 FT.COIL

1000 FT.REEL

WEIGHTS AND MEASUREMENTS

COLOR CODING

PACKAGING

Page 17: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS USEDÛ For certain applications:

- For branch-circuit wiring, electrical systems in patient care areas of hospitals, nursing homes, dental offices,outpatient facilities and other medical or health related facilities- Fished or embedded in plaster- For cable trays and approved raceways- Applications require redundant, dedicated or isolated grounding paths

Û For certain locations:- Environmental air-handling spaces, per NEC 300.22(C)- Under raised floors for information technology equipment conductors and cables, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- Prohibited in hazardous anesthetizing areas and electrical system circuits, except where permitted,per 2005 NEC 517.30(C)(3)(3)

HOW ITÊS MADEÛ Conductors: Type THHN/THWN, solid soft-drawn copper that is available in sizes 12 AWG – 10 AWG and is rated 90■C dryÛ It has a green, insulated, copper ground wire and a bare aluminum, grounding conductorÛ Insulated cables are combined using binder tape and a green lightweight aluminum interlocking armor is

placed over the cablesÛ The bare aluminum, grounding conductor is located outside of the binding tape and has the same lay as the

insulated conductors

HOW ITÊS CERTIFIEDÛ SouthwireÊs Armorlite® HCF Type MCAP™meets or exceeds the requirements of UL 1569 Standard for Metal-Clad

Cables, NFPA 70 National Electrical Code, UL 83 Standard, UL 1063 Standard, Federal Specification A-A59544(formerly-C-30B) and IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test. SouthwireÊs Armorlite® HCFType MCAP™ is listed for use in UL 1, 2 and 3 Hour Through-Penetration Firestop Systems.

HOW ITÊS DEFINEDÛ An armor assembly that is an equipment grounding conductor per 2005 NEC 250.118(10)(A)Û Installation instructions included with every reel and coilÛ 350% better redundant ground path over traditional Type AC HCF cableÛ Reduces installation costs up to 50% over pipe and wireÛ Increased labor savings compared to Type AC HCFÛ UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113,

W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173,C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038

Û When pulling from coils, pull from inside to ensure ease of installation. For easier installation and pulling cablereverse wound on reel.

68

Û MCAP: Metal Clad AllPurpose

Û HCF: Hospital CareFacility

Û 600 Volts

MCAP ®HCFALL-PURPOSE METAL CLAD

EquipmentGroundingConductor

Page 18: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

69

MCA

P®H

CFA

LL-P

URP

OSE

MET

AL

CLA

D

CONDUCTORSIZE (AWG)/#OF PHASE

CONDUCTORS

CONDUCTORTYPE

GROUNDINGBONDING

CONDUCTOR

GREEN THHNCOPPERGROUND(AWG)

AMPACITIES (AMPS)OVERALLDIAMETER(INCHES) 60■C 75■C 90■C

12/212/312/410/210/310/4

SOLIDSOLIDSOLIDSOLIDSOLIDSOLID

10 SOLID AL10 SOLID AL10 SOLID AL10 SOLID AL10 SOLID AL10 SOLID AL

121212101010

.445

.480

.515

.520

.565

.670

202020303030

202020303030

202020303030

COLOR CODING

234

STANDARD COLOR 120/208Y SPECIAL COLOR 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

# OF CONDUCTORS

Grounding Conductor is Green.

PACKAGING12/2 12/3 12/4 10/2 10/3 10/4

250 FTCOIL

1000 FTREEL

WEIGHTS AND MEASUREMENTS

Page 19: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral wound strip of corrosion-resistant, hot-dipped galvanized steelÛ Steel has a heavy zinc coating

70

Û Data Flex: FlexibleMetal Conduit

Û Crush/Corrosion ResistantÛ Smooth Interior for Easy

Pulling

HOW ITÊS USEDÛ For concealed, exposed or approved racewaysÛ For use where listed products are not required

Data Flex®

FLEXIBLE METAL CONDUIT

Page 20: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

71

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

44568101215182124

3/81/23/41

1-1/41-1/2

22-1/2

33-1/2

4

1219.523.530376693150190220264

.585

.8751.0751.3401.5901.9002.4002.9603.4603.9604.460

Da

taFl

ex®

FLEX

IBLE

MET

AL

CO

ND

UIT

3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250FTCOIL

25FTCOIL50FTCOIL100FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 21: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Lightweight, high strength aluminum alloyÛ Metal strip, helically formed, making continuously interlocked flexible metal conduit

HOW ITÊS CERTIFIEDÛ UL Listed per UL 1, Standard for Safety for Flexible Metal Conduit, ANSI/UL-1Û CSA Listed per CSA 22.2 No. 56 per Canadian Electrical Code C22.1 Section 12-1000 for 5/16" and 3/8"

trade sizes onlyÛ Meets federal specification WW-C-566cÛ NEC Type Designation - Article 348, Type FMC (flexible metal conduit)

72

Û RWA: Reduced WallAluminum

Û Highly FlexibleÛ 66% Lighter than SteelÛ Cuts 80% Faster than SteelÛ Corrosion and Crush

ResistantÛ Smooth Metal Interior for

Easy Wiring

HOW ITÊS USEDÛ For certain applications:

- For power and lighting branch circuit conductors and cables such as: receptacles, equipment and officepartitions, etc.- For voice, data, communications, video, CATV and optical fiber cables- For motor feeders, branch, control circuits and cables- For use with listed connectors for NEC type FMC (Flexible Metal Conduit)- Listed wire fixtures, per NEC 410.77(C)- Elevators and escalators, per NEC 620.21- Cranes and hoists, per NEC 610.11(C)- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 Volts)- Metal raceway, per NEC (ANSI/NFPA-70) Article 348- Fire alarm systems of power-limited or non-power-limited fire alarm circuits- As a grounding conductor for lengths up to 6 feet, per 2005 NEC 205.118(5)- Class 1, Class 2 and Class 3 Remote-control, signaling and power-limited circuit conductors and cables- UL 1, 2 & 3 Hour Through-Penetration Firestop Systems: C-AJ-1462, C-AJ-1463 and C-AJ-1464 as well asW-L-1308 and W-L-1309

Û For certain locations:- For exposed or concealed locations, per NEC Article 348 and the applicable NEC provisions- Under raised floors for information technology, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- Hazardous locations: Class 1 Div. 2, for flexible conductors only, per 2005 NEC 501.10(B)(2) & 501.30(B)

Û For certain conditions:- For environmental air-handling spaces, per NEC 300.22(C)

Alflex®RWAFLEXIBLE METAL CONDUIT

Page 22: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

73

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.470 / 0.5100.560 / 0.6100.860 / 0.9201.045 / 1.1051.300 / 1.3801.550 / 1.6301.850 / 1.9502.350 / 2.4502.860 / 3.0603.360 / 3.5603.860 / 4.0604.360 / 4.560

3.546810

12.5152025303540

5/163/81/23/41

1-1/41-1/2

22-1/2

33-1/2

4

5.579

12.52532467092107125142

0.312/-0.375 / 0.3930.625 / 0.6450.812 / 0.8351.0000 / 1.0401.250 / 1.3001.500 / 1.5752.000 / 2.080

2.500 / -3.000 / -3.500 / -4.000 / -

Alflex

®RW

AFL

EXIB

LEM

ETA

LC

ON

DU

IT

MINIMUMBENDINGRADIUS

(INCHES)

PACKAGING3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250 FTCOIL

25 FTCOIL50 FTCOIL

100 FTCOIL

WEIGHTS AND MEASUREMENTS

Page 23: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Galvanized, corrosion resistant, high strength steel alloyÛ Metal strip, helically formed, making continuously interlocked flexible metal conduitÛ Built in flexibility for simplified positioningÛ Provides mechanical protection for conductors and cablesÛ For use with listed connectors intended for NEC Type FMC (Flexible Metal Conduit)

HOW ITÊS CERTIFIEDÛ UL Listed per UL 1, Standard for Safety for Flexible Metal Conduit, ANSI/UL-1 for 5/16" through 3‰Û CSA Listed for 5/16‰ and 3/8‰ sizesÛ Meets federal specification WW-C-566cÛ NEC Type Designation - Article 348, Type FMC (flexible metal conduit)

74

Û RWS: Reduced WallSteel

Û Highly FlexibleÛ High Strength Steel

ConstructionÛ Hot-Dipped, Heavy Zinc

CoatingÛ Corrosion and Crush

ResistantÛ Smooth Metal Interior for

Easy Wiring

HOW ITÊS USEDÛ For certain applications:

- For power and lighting branch circuit conductors and cables such as: receptacles, equipment and officepartitions, etc.- For voice, data, communications, video, CATV and optical fiber cables- For motor feeders, branch, control circuits and cables- For use with listed connectors for NEC type FMC (Flexible Metal Conduit)- Listed wire fixtures, per NEC 410.77(C)- Elevators and escalators, per NEC 620.21- Cranes and hoists, per NEC 610.11(C)- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 Volts)- Metal raceway, per NEC (ANSI/NFPA-70) Article 348- Fire alarm systems of power-limited or non-power-limited fire alarm circuits- As a grounding conductor for lengths up to 6 feet, per 2005 NEC 205.118(5)- Class 1, Class 2 and Class 3 Remote-control, signaling and power-limited circuit conductors and cables- UL 1, 2 & 3 Hour Through-Penetration Firestop Systems: C-AJ-1462, C-AJ-1463 and C-AJ-1464 as wellas W-L-1308 and W-L-1309

Û For certain locations:- For exposed or concealed locations, per NEC Article 348 and the applicable NEC provisions- Under raised floors for information technology, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- Hazardous locations: Class 1 Div. 2, for flexible conductors only, per 2005 NEC 501.10(B)(2) & 501.30(B)

Û For certain conditions:- For environmental air-handling spaces, per NEC 300.22(C)

Galflex®RWSFLEXIBLE METAL CONDUIT

Page 24: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

75

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.470 / 0.5100.560 / 0.6100.860 / 0.9201.045 / 1.1051.300 / 1.3801.550 / 1.6301.850 / 1.9502.350 / 2.4502.860 / 3.0603.360 / 3.5603.860 / 4.0604.360 / 4.560

3.544568101215182124

5/163/81/23/41

1-1/41-1/2

22-1/2

33-1/2

4

161827

34.5576878133165197231264

0.312/-0.375 / 0.3930.625 / 0.6450.812 / 0.8351.000 / 1.0401.250 / 1.3001.500 / 1.5752.000 / 2.080

2.500 / -3.000 / -3.500 / -4.000 / -

Galflex

®RW

SFL

EXIB

LEM

ETA

LC

ON

DU

IT

MINIMUMBENDINGRADIUS

(INCHES)

PACKAGING3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250 FTCOIL

25 FTCOIL50 FTCOIL

100 FTCOIL

WEIGHTS AND MEASUREMENTS

Page 25: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral wound strip of corrosion-resistant, hot dipped galvanized steelÛ Steel has a heavy zinc coatingÛ Superior crush resistant sheilding for floor, wall and ceiling cables

HOW ITÊS CERTIFIEDÛ UL Component Recognized.

76

Û Slinky Flex: ExtraFlexible Metal Conduit

Û Crush/Corrosion ResistantÛ Smooth Interior for Easy

Pulling

HOW ITÊS USEDÛ For office partition furniture, voice, data, CATV, signal transmissions, and other OEM applicationsÛ For concealed, exposed or approved racewaysÛ For applications where extra flexibility is needed

Slinky Flex®

EXTRA FLEXIBLE METAL CONDUIT

Page 26: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

77

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.447 / 0.4720.515 / 0.5400.585 / 0.6100.640 / 0.6650.703 / 0.7280.890 / 0.915

APPROX. BENDRADIUS(INCHES)

1.51.75

24

4.55

5/163/87/161/29/163/4

12.514.5171921

27.5

0.312 / 0.3370.375 / 0.4000.437 / 0.4620.500 / 0.5250.563 / 0.5880.750 / 0.775

Slin

ky

Flex

®

EXTR

AFL

EXIB

LEM

ETA

LC

ON

DU

IT1/2‰, 3/4‰ conduit minimum bend radius based on NEC Chapter 9.

PACKAGING1/25/16 3/8 7/16 9/16 3/4

250FTCOIL

1000FTCOIL

50FTCOIL100FTCOIL

METAL CLAD& CONDUIT

WEIGHTS AND MEASUREMENTS

77

Slin

ky

Flex

®

EXTR

AFL

EXIB

LEM

ETA

LC

ON

DU

IT

Page 27: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Lightweight, high strength aluminum alloyÛ Metal strip, helically formed, making continuously interlocked flexible metal conduit

HOW ITÊS CERTIFIEDÛ UL Listed per UL 1, Standard for Safety for Flexible Metal Conduit, ANSI/UL-1Û CSA Listed per CSA 22.2 No. 56 per Canadian Electrical Code C22.1 Section 12-1000 for 5/16" and 3/8"trade sizes only

Û Meets federal specification WW-C-566cÛ NEC Type Designation - Article 348, Type FMC (flexible metal conduit)

78

Û SWA: Standard WallAluminum

Û Highly FlexibleÛ 66% Lighter than SteelÛ Cuts 80% Faster than SteelÛ Corrosion and Crush

ResistantÛ Smooth Metal Interior for

Easy Wiring

HOW ITÊS USEDÛ For certain applications:

- For power and lighting branch circuit conductors and cables such as: receptacles, equipment and officepartitions, etc.- For voice, data, communications, video, CATV and optical fiber cables- For motor feeders, branch, control circuits and cables- For use with listed connectors for NEC type FMC (Flexible Metal Conduit)- Listed wire fixtures, per NEC 410.77(C)- Elevators and escalators, per NEC 620.21- Cranes and hoists, per NEC 610.11(C)- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 Volts)- Metal raceway, per NEC (ANSI/NFPA-70) Article 348- Fire alarm systems of power-limited or non-power-limited fire alarm circuits- As a grounding conductor for lengths up to 6 feet, per 2005 NEC 205.118(5)- Class 1, Class 2 and Class 3 Remote-control, signaling and power-limited circuit conductors and cables- UL 1, 2 & 3 Hour Through-Penetration Firestop Systems: C-AJ-1462, C-AJ-1463 and C-AJ-1464 as well as W-L-1308andW-L-1309

Û For certain locations:- For exposed or concealed locations, per NEC Article 348 and the applicable NEC provisions- Under raised floors for information technology, per NEC 645.5(D) and 645.5(D)(2)- For places of assembly and theaters, per NEC Articles 518 and 520- Hazardous locations: Class 1 Div. 2, for flexible conductors only, per 2005 NEC 501.10(B)(2) & 501.30(B)

Û For certain conditions:- For environmental air-handling spaces, per NEC 300.22(C)

Alflex®SWAFLEXIBLE METAL CONDUIT

Page 28: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

79

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.470 / 0.5100.560 / 0.6100.860 / 0.9201.045 / 1.1051.300 / 1.3801.550 / 1.6301.850 / 1.9502.350 / 2.4502.860 / 3.0603.360 / 3.5603.860 / 4.0604.360 / 4.560

3.544568101215182124

5/163/81/23/41

1-1/41-1/2

22-1/2

33-1/2

4

5.5715204049567092107125142

0.312/-0.375 / 0.3930.625 / 0.6450.812 / 0.8351.000 / 1.0401.250 / 1.3001.500 / 1.5752.000 / 2.080

2.500 / -3.000 / -3.500 / -4.000 / -

Alflex

®SW

AFL

EXIB

LEM

ETA

LC

ON

DU

IT

MINIMUMBENDINGRADIUS(INCHES)

3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250FTCOIL

25FTCOIL50FTCOIL100FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 29: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral wound strip of heavy gauge, corrosion-resistant, hot-dipped galvanized steelÛ For 3/8‰ through 1-1/4‰ sizes, the core has a square, locked, steel strip with a copper bonding strip enclosedwithin the steel convolutions

Û Jacket: Rugged, flame retardant, flexible, UV sunlight resistant, gray, PVC jacketÛ Other jacket colors are available; however, the blue color easily identifies raceways for uninterrupted computer power circuitsÛ Protects against liquids, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, salt, air,alkalines, oil, certain chemicals, temperatures, sunlight and weather.

HOW ITÊS CERTIFIEDÛ CSA Listed to CSA 22.2 No.56 for use per the Canadian Electrical Code C22.1 Section 12-1300.Û UL Listed to Underwriters Laboratories Standard ANSI / UL-360 for Liquidtight Flexible Steel Conduit.Û NEC Type designation - Type LFMC (Liquidtight Flexible Metal Conduit).Û ANSI / NFPA-70, NEC Article 350.

80

Û CB: Computer BlueÛ Rated -30■C to 80■CÛ Crush/Corrosion, Oil and

Sunlight ResistantÛ Accepts Standard Metallic

Liquidtight FittingsÛ Rated for Direct BurialÛ Smooth Metal Interior for

Easy Pulling

HOW ITÊS USEDÛ For certain conditions:

- For extreme oil and solvent environments- Where conditions of installation, operation or maintenance require flexibility and/or protection fromliquids, vapors, solids or weather- For the installation and protection of electrical conductors in circuits or 600 Volts or less- For equipment grounding in sizes 3/8‰ through 1-1/4‰ in lengths not exceeding 6 feet, per NEC 250.118(6)

Û For certain locations:- For exposed or concealed locations- Under raised floors in data processing areas per NEC 645.5(D) and 645.5(D)(2)- Service entrances, up to 6 feet in length per NEC 230.43 (15)- Hazardous locations: where necessary for flexible connections, in accordance with the following:•Class 1, Div. 2 - NEC 501.10(B)(2) & 501.30(B)•Class 2, Div. 1 - NEC 502.10(A)(2) & 502.30(B)•Class 2, Div. 2 - NEC 502.10(B)(2)•Class 3, Div. 1 - NEC 503.10(A)(2) & 503.30(B)•Class 3, Div. 2 - NEC 503.10(A)(2)

Û For certain applications:- For applications requiring movement, crossover connections or tight bends- For industrial and commercial applications for conveyors, blowers, air conditioners, machine tooling andlubrication equipment- Elevators, escalators, moving walks, wheel chair lifts and stairway chair lifts, per NEC 620.01, where permitted- Cranes and hoists, per NEC 610.11(C)- Boatyards and marinas, per NEC 555.13- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 volts)- Floating building feeders and services, per NEC 553.7(B)

Titan™ CBLIQUIDTIGHT FLEXIBLE METAL CONDUIT

Page 30: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

81

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.3752.840 / 2.8753.460 / 3.5003.960 / 4.0004.460 / 4.500

APPROX. BENDRADIUS*(INCHES)

44568101215182124

3/81/23/41

1-1/41-1/2

22-1/2

33-1/2

4

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.0452.480 / 2.5053.070 / 3.1003.500 / 3.5404.000 / 4.040

Titan™

CBLIQ

UID

TIG

HT

FLEX

IBLE

MET

AL

CO

ND

UIT

*Minimum bend radius based on NEC Chapter 9.

27314076102103145197265300333

3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250FTCOIL

25FTCOIL50FTCOIL100FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 31: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral wound, interlocked aluminum strip of corrosion-resistant galvanized steelÛ Gray PVC jacket is flexible, flame retardant and resists oils, mild acids as well as exposure to sunlight

82

Û EF: Extra-FlexibleÛ Rated -10■C to 60■CÛ Liquidtight Metal ConduitÛ Resistant to Weather,

Heat, Oil and ChemicalBreakdown

Û Smooth Metal Interior forEasy Pulling

HOW ITÊS USEDÛ For concealed or exposed installations requiring movement, crossover connections or tight bendsÛ Seals out alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acid, non-concentrated fixedalkalines, petroleum oils, salt air spray, water and various weather conditions

Û Used in industrial and commercial applications for conveyors, blowers, cranes, air conditioners, machinetooling and lubrication equipment where UL listing is not required

Û Provides wiring protection where listed products are not required

Titan™ EFLIQUIDTIGHT FLEXIBLE METAL CONDUIT

Page 32: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

83

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.3752.840 / 2.8753.460 / 3.5003.960 / 4.0004.460 / 4.500

APPROX.BENDRADIUS(INCHES)

44568101215182124

3/81/23/41

1-1/41-1/22

2-1/23

3-1/24

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.0452.480 / 2.5053.070 / 3.1003.500 / 3.5404.000 / 4.040

Tita

n™EF

LIQUIDTIGHTFLEXIBLEMETALCONDUIT

222329587395131156209259306

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.3752.840 / 2.8753.460 / 3.5003.960 / 4.0004.460 / 4.500

444.55.757.258.259.510.5131516

3/81/23/41

1-1/41-1/22

2-1/23

3-1/24

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.0452.480 / 2.5053.070 / 3.1003.500 / 3.5404.000 / 4.040

15162041516792109146181214

ALUMINUM CORE EXTRA FLEXIBLE LIQUIDTIGHT METALLIC CONDUIT

3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250FTCOIL

25FTCOIL50FTCOIL100FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 33: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral wound strip of heavy gauge, corrosion-resistant, hot-dipped galvanized steelÛ For 3/8‰ through 1-1/4‰ sizes, the core has a square, locked, steel strip with a copper bonding strip enclosedwithin the steel convolutions

Û Jacket: Rugged, flame retardant, flexible, PVC jacket that is rated for extreme hot and cold temperatureenvironments

Û Protects against liquids, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, salt, air,alkalines, oil, certain chemicals, temperatures, sunlight and weather.

84

Û HC: Hot/ColdÛ Rated -40■C to 105■CÛ Oil and Sunlight ResistantÛ Accepts Standard Metallic

Liquidtight FittingsÛ Rated for direct burialÛ Smooth Metal Interior for

Easy Pulling

HOW ITÊS USEDÛ For certain conditions:

- For extreme oil and solvent environments- Where conditions of installation, operation or maintenance require flexibility and/or protection fromliquids, vapors, solids or weather- For the installation and protection of electrical conductors in circuits or 600 Volts or less- For equipment grounding in sizes 3/8‰ through 1-1/4‰ in lengths not exceeding 6 feet, per NEC 250.118(6)

Û For certain locations:- For exposed or concealed locations- Under raised floors in data processing areas per NEC 645.5(D) and 645.5(D)(2)- Service entrances, up to 6 feet in length per NEC 230.43 (15)- Hazardous locations: where necessary for flexible connections, in accordance with the following:•Class 1, Div. 2 - NEC 501.10(B)(2) & 501.30(B)•Class 2, Div. 1 - NEC 502.10(A)(2) & 502.30(B)•Class 2, Div. 2 - NEC 502.10(B)(2)•Class 3, Div. 1 - NEC 503.10(A)(2) & 503.30(B)•Class 3, Div. 2 - NEC 503.10(A)(2)

Û For certain applications:- For applications requiring movement, crossover connections or tight bends- For industrial and commercial applications for conveyors, blowers, air conditioners, machine tooling andlubrication equipment- Elevators, escalators, moving walks, wheel chair lifts and stairway chair lifts, per NEC 620.01, where permitted- Cranes and hoists, per NEC 610.11(C)- Boatyards and marinas, per NEC 555.13- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 volts)- Floating building feeders and services, per NEC 553.7(B)

Titan™ HCLIQUIDTIGHT FLEXIBLE METAL CONDUIT

HOW ITÊS CERTIFIEDÛ UL Listed to Underwriters Laboratories Standard ANSI / UL-360 for Liquidtight Flexible Steel Conduit.Û CSA Listed to CSA 22.2 No.56 for use per the Canadian Electrical Code C22.1 Section 12-1300.Û NEC Type designation - Type LFMC (Liquidtight Flexible Metal Conduit).Û ANSI / NFPA-70, NEC Article 350.

Page 34: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

85

SIZE(INCHES)

APPROXIMATEWEIGHT

(lbs/100 ft)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.3752.840 / 2.8753.460 / 3.5003.960 / 4.0004.460 / 4.500

APPROX. INSIDEBEND DIAMETER

(INCHES)

46.58.5131618

22.2529.25

354048

3/81/23/41

1-1/41-1/2

22-1/2

33-1/2

4

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.0452.480 / 2.5053.070 / 3.1003.500 / 3.5404.000 / 4.040

Titan™

HC

LIQU

IDTI

GH

TFL

EXIB

LEM

ETA

LC

ON

DU

IT

27314076102103145197265300333

3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250FTCOIL

25FTCOIL50FTCOIL100FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 35: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral wound strip of heavy gauge, corrosion-resistant, hot-dipped galvanized steelÛ For 3/8‰ through 1-1/4‰ sizes, the core has a square, locked, steel strip with a copper bonding strip enclosed

within the steel convolutionsÛ Jacket: Rugged, flame retardant, flexible, PVC jacket that is rated for extreme oil and solvent environmentsÛ Protects against liquids, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, salt, air,

alkalines, oil, certain chemicals, temperatures, sunlight and weather

HOW ITÊS CERTIFIEDÛ UL Listed to Underwriters Laboratories Standard ANSI / UL-360 for Liquidtight Flexible Steel Conduit.Û CSA Listed to CSA 22.2 No.56 for use per the Canadian Electrical Code C22.1 Section 12-1300.Û NEC Type designation - Type LFMC (Liquidtight Flexible Metal Conduit).Û ANSI / NFPA-70, NEC Article 350.

86

Û OR: Oil ResistantÛ Rated -30■C to 80■CÛ Sunlight ResistantÛ Rated for Extreme Oil and

Solvent EnvironmentsÛ Accepts standard metallic

liquid-tight fittingsÛ Rated for direct burial

applicationsÛ Smooth Metal Interior for

Easy Pulling

HOW ITÊS USEDÛ For certain conditions:

- For extreme oil and solvent environments- Where conditions of installation, operation or maintenance require flexibility and/or protection fromliquids, vapors, solids or weather- For the installation and protection of electrical conductors in circuits or 600 Volts or less- For equipment grounding in sizes 3/8‰ through 1-1/4‰ in lengths not exceeding 6 feet, per NEC 250.118(6)

Û For certain locations:- For exposed or concealed locations- Under raised floors in data processing areas per NEC 645.5(D) and 645.5(D)(2)- Service entrances, up to 6 feet in length per NEC 230.43 (15)- Hazardous locations: where necessary for flexible connections, in accordance with the following:

•Class 1, Div. 2 - NEC 501.10(B)(2) & 501.30(B)•Class 2, Div. 1 - NEC 502.10(A)(2) & 502.30(B)•Class 2, Div. 2 - NEC 502.10(B)(2)•Class 3, Div. 1 - NEC 503.10(A)(2) & 503.30(B)•Class 3, Div. 2 - NEC 503.10(A)(2)

Û For certain applications:- For applications requiring movement, crossover connections or tight bends- For industrial and commercial applications for conveyors, blowers, air conditioners, machine tooling andlubrication equipment- Elevators, escalators, moving walks, wheel chair lifts and stairway chair lifts, per NEC 620.01,where permitted- Cranes and hoists, per NEC 610.11(C)- Boatyards and marinas, per NEC 555.13- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 volts)- Floating building feeders and services, per NEC 553.7(B)

Titan™ ORLIQUIDTIGHT FLEXIBLE METAL CONDUIT

Page 36: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

87

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.3752.840 / 2.8753.460 / 3.5003.960 / 4.0004.460 / 4.500

APPROX.BENDRADIUS(INCHES)

24568101215182124

3/81/23/41

1-1/41-1/22

2-1/23

3-1/24

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.0452.480 / 2.5053.070 / 3.1003.500 / 3.5404.000 / 4.040

Tita

n™O

RLIQUIDTIGHTFLEXIBLEMETALCONDUIT

27314076102103145197265300333

3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250FTCOIL

25FTCOIL50FTCOIL100FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 37: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral wound strip of heavy gauge, corrosion-resistant, hot-dipped galvanized steelÛ For 3/8‰ through 1-1/4‰ sizes, the core has a square, locked, steel strip with a copper bonding strip enclosed

within the steel convolutionsÛ Jacket: Rugged, flame retardant, flexible, UV sunlight resistant, grey, PVC jacketÛ Protects against liquids, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, salt, air,

alkalines, oil, certain chemicals, temperatures, sunlight and weather

HOW ITÊS CERTIFIEDÛ UL Listed to Underwriters Laboratories Standard ANSI / UL-360 for Liquidtight Flexible Steel Conduit.Û CSA Listed to CSA 22.2 No.56 for use per the Canadian Electrical Code C22.1 Section 12-1300.Û NEC Type designation - Type LFMC (Liquidtight Flexible Metal Conduit).Û ANSI / NFPA-70, NEC Article 350.

88

Û UL: UnderwritersLaboratories

Û Rated for -30■C to80■C, 60■C for Oil

Û Crush/Corrosion, Oil andSunlight Resistant

Û Accepts Standard MetallicLiquidtight FittingsRated for Direct Burial

Û Smooth Metal Interior forEasy Pulling

HOW ITÊS USEDÛ For certain conditions:

- For extreme oil and solvent environments- Where conditions of installation, operation or maintenance require flexibility and/or protection fromliquids, vapors, solids or weather- For the installation and protection of electrical conductors in circuits or 600 Volts or less- For equipment grounding in sizes 3/8‰ through 1-1/4‰ in lengths not exceeding 6 feet, per NEC 250.118(6)

Û For certain locations:- For exposed or concealed locations- Under raised floors in data processing areas per NEC 645.5(D) and 645.5(D)(2)- Service entrances, up to 6 feet in length per NEC 230.43 (15)- Hazardous locations: where necessary for flexible connections, in accordance with the following:

•Class 1, Div. 2 - NEC 501.10(B)(2) & 501.30(B)•Class 2, Div. 1 - NEC 502.10(A)(2) & 502.30(B)•Class 2, Div. 2 - NEC 502.10(B)(2)•Class 3, Div. 1 - NEC 503.10(A)(2) & 503.30(B)•Class 3, Div. 2 - NEC 503.10(A)(2)

Û For certain applications:- For applications requiring movement, crossover connections or tight bends- For industrial and commercial applications for conveyors, blowers, air conditioners, machine tooling andlubrication equipment- Elevators, escalators, moving walks, wheel chair lifts and stairway chair lifts, per NEC 620.01,where permitted- Cranes and hoists, per NEC 610.11(C)- Boatyards and marinas, per NEC 555.13- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 volts)- Floating building feeders and services, per NEC 553.7(B)

Titan™ ULLIQUIDTIGHT FLEXIBLE METAL CONDUIT

Page 38: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

89

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.3752.840 / 2.8753.460 / 3.5003.960 / 4.0004.460 / 4.500

APPROX. BENDRADIUS*(INCHES)

44568101215182124

3/81/23/41

1-1/41-1/2

22-1/2

33-1/2

4

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.0451.575 / 1.6001.575 / 1.6001.575 / 1.6001.575 / 1.600

Titan™UL

LIQU

IDTI

GH

TFL

EXIB

LEM

ETA

LC

ON

DU

IT

*Minimum bend radius based on NEC Chapter 9.

37314076102103145197265300333

3/45/16 3/8 1/2 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

250FTCOIL

25FTCOIL50FTCOIL100FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 39: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral of rigid PVC reinforcment imbedded within a flexible PVC wallÛ Thermoplastic materials protect and form the conduit which seals out water, liquids, alcohol, coolants,corrosive fumes and gases, dirt grease, oil, mild acids, non-concentrated fixed alkalines, various weatherconditions and exposure to sun

90

Û NM: Non-MetallicÛ For Dry LocationsÛ Rated -30■C to 80■C,

Rated 60■C OilÛ For Direct Burial &

Encased in ConcreteÛ Highly FlexibleÛ Crush ResistantÛ Smooth Metal Interior for

Easy Wiring

HOW ITÊS USEDÛ For certain conditions:

- Where conditions of installation, operation or maintenance require flexibility and/or protection fromliquids, vapors, solids or weather- For the installation and protection of electrical conductors in circuits of 600 Volts or less

Û For certain locations:- For exposed or concealed locations- Under raised floors in data processing areas per NEC 645.5(D) and 645.5(D)(2)- For use in lengths longer than 6 feet, per NEC 356.10(5)- Hazardous locations: where necessary for flexible connections, in accordance with the following:•Class 1, Div. 2 - NEC 501.10(B)(2) & 501.30(B)•Class 2, Div. 1 - NEC 502.10(A)(2) & 502.30(B)•Class 2, Div. 2 - NEC 502.10(B)(2)•Class 3, Div. 1 - NEC 503.10(A)(2) & 503.30(B)•Class 3, Div. 2 - NEC 503.10(A)(2)

Û For certain applications:- For motor circuits - motor feeders, branch and control circuits- For applications requiring movement, crossover connections or tight bends- For industrial and commercial applications for conveyors, blowers, air conditioners, machine tooling andlubrication equipment- Elevators, escalators, moving walks, wheel chair lifts and stairway chair lifts, per NEC 620.21, where permitted- Cranes and hoists, per NEC 610.11(C)- Boatyards and marinas, per NEC 555.13- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 Volts)- Floating building feeders and services, per NEC 553.7(B)- Service entrances, up to 6 feet in length per NEC 230.43 (15)- Agricultural buildings, per NEC 547.5- Motor leads, per NEC 430.145(B)- Swimming pools, spa and hot tub motors, per NEC 680.21 (A)(E) & 680.42(A)(!)

Ultratite® NMLIQUIDTIGHT FLEXIBLE CONDUIT

HOW ITÊS CERTIFIEDÛ NEC Type designation - Type LFNC-B (Liquidtight Flexible Nonmetallic Conduit).Û ANSI / NFPA-70, NEC Article 356.Û UL Listed to Underwriters Laboratories Standard UL 1660.Û Approved by Canadian Standards Association.

Page 40: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

91

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.375

APPROX.BENDRADIUS(INCHES)

445681012

3/81/23/41

1-1/41-1/2

2

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.045

Ultr

atit

e®N

MLIQ

UID

TIG

HT

FLEX

IBLE

CO

ND

UIT

10.5131827344564

3/43/8 1/2 1 1-1/4 1-1/2 2

250FTREEL400FTREEL600FTREEL1000FTREEL

50FTCOIL100FTCOIL150FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 41: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral of rigid PVC imbedded in a flexible PVC wallÛ Provides excellent impact and crush strength

HOW ITÊS CERTIFIEDÛ UL component recognized per UL Standard for Safety, UL 1660.

92

Û NMEF: Non-MetallicExtra Flexible

Û Rated -10■C to 60■CÛ Resistant to Oil, Water,

Rust and Most ChemicalsÛ Smooth Interior for Easy

Pulling

HOW ITÊS USEDÛ For use where vibrations or harsh environments existÛ Seals out alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, non-concentrated

fixed alkalines, petroleum oils, salt, water and various weather conditionsÛ Provides wiring protection where listed products are not required

Ultratite® NMEFLIQUIDTIGHT FLEXIBLE CONDUIT

Page 42: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

93

SIZE(INCHES)

APPROXIMATEWEIGHT

(lbs/100 ft)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.375

APPROX.INSIDEBEND DIAMETER

(INCHES)

445681012

3/81/23/41

1-1/41-1/2

2

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.045

5.58.810.518.5202332

3/43/8 1/2 1 1-1/4 1-1/2 250FTCOIL100FTCOIL

Ultratite®NMEF

LIQU

IDTI

GH

TFL

EXIB

LEC

ON

DU

IT

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 43: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral of rigid PVC reinforcement imbedded within a flexible PVC wallÛ Thermoplastic materials protect and form the conduit which seals out water, liquids, alcohol, coolants,corrosive fumes and gases, dirt, grease, oil, mild acids, non-concentrated fixed alkalines, various weatherconditions and exposure to sun

HOW ITÊS CERTIFIEDÛ NEC Type designation - Type LFNC-B (Liquidtight Flexible Nonmetallic Conduit).Û ANSI / NFPA-70, NEC Article 356.Û UL Listed to Underwriters Laboratories Standard UL 1660.Û Approved by Canadian Standards Association.

94

Û NMHC: Non-MetallicHot/Cold

Û For Dry LocationsÛ Rated -30■C to 80■CÛ For Direct Burial &

Encased in ConcreteÛ Highly FlexibleÛ Crush ResistantÛ Smooth Metal Interior for

Easy Wiring

HOW ITÊS USEDÛ For certain conditions:

- For direct burial and concrete applications- For motor circuits - motor feeders, branch and control circuits- For applicaitons requiring movement, crossover connections or tight bends- For industrial and commerical applications for conveyors, blowers, air conditioners, machine tooling andlubrication equipment- Elevators, escalators, moving walks, wheel chair lifts and stairway chair lifts, per NEC 620.21,where permitted- Cranes and hoists, per NEC 610.11(C)- Boatyards and marinas, per NEC 555.13- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 Volts)- Floating building feeders and services, per NEC 553.7(B)- Service entrances, up to 6 feet in length per NEC 230.43 (15)- Agricultural buildings, per NEC 547.5- Motor leads, per NEC 430.145(B)- Swimming pools, spa and hot tub motors, per NEC 680.21 (A)(E) & 680.42(A)(1)

Û For certain locations:- For exposed or concealed locations- Under raised floors in data processing areas per NEC 645.5(D) and 645.5(D)(2)- For use in lengths longer than 6 feet, per NEC 356.10(5)- Hazardous locations: where necessary for flexible connections, in accordance with the following:1. Class 1, Div. 2 - NEC 501.10(B)(2) & 501.30(B)2. Class 2, Div. 1 - NEC 502.10(A)(2) & 502.30(B)3. Class 2, Div. 2 - NEC 502.10(B)(2)4. Class 3, Div. 1 - NEC 503.10(A)(2) & 503.30 (B)5. Class 3, Div. 2 - NEC 503.10(A)(2)

Û For certain conditions:- For environments with extreme hot and cold temperatures- Where conditions of installation, operation maintence require flexiblity, and/or protection from liquids, vapors,solids, weather- For the installation and protection of electrical conductors in circuits of 600 Volts or less

Ultratite® NMHCLIQUIDTIGHT FLEXIBLE CONDUIT

Page 44: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

95

SIZE(INCHES)

APPROXIMATEWEIGHT

(lbs/100 ft)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.375

APPROX.INSIDEBEND DIAMETER

(INCHES)

46.58.5131618

22.2

3/81/23/41

1-1/41-1/2

2

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.045

Ultratite®NMHC

LIQU

IDTI

GH

TFL

EXIB

LEC

ON

DU

IT

10.5131827344564

3/43/8 1/2 1 1-1/4 1-1/2 2

250FTREEL400FTREEL600FTREEL1000FTREEL

50FTCOIL100FTCOIL150FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 45: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Spiral of rigid PVC reinforcement imbedded within a flexible PVC wallÛ Thermoplastic materials protect and form the conduit which seals out water, liquids, alcohol, coolants,corrosive fumes and gases, dirt, grease, oil, mild acids, non-concentrated fixed alkalines, various weather.conditions and exposure to sun

HOW ITÊS CERTIFIEDÛ NEC Type designation - Type LFNC-B (Liquidtight Flexible Nonmetallic Conduit).Û ANSI / NFPA-70, NEC Article 356.Û UL Listed to Underwriters Laboratories Standard UL 1660.Û Approved by Canadian Standards Association.96

Û NMOR: Non-MetallicOil Resistant

Û For Dry LocationsÛ Rated -30■C to 80■CÛ For Direct Burial &

Encased in ConcreteÛ Highly FlexibleÛ Crush ResistantÛ Smooth Metal Interior for

Easy Wiring

HOW ITÊS USEDÛ For certain conditions:

- For direct burial and concrete applications- For motor circuits - motor feeders, branch and control circuits- For applicaitons requiring movement, crossover connections or tight bends- For industrial and commerical applications for conveyors, blowers, air conditioners, machine tooling andlubrication equipment- Elevators, escalators, moving walks, wheel chair lifts and stairway chair lifts, per NEC 620.21,where permitted- Cranes and hoists, per NEC 610.11(C)- Boatyards and marinas, per NEC 555.13- Electric signs and outline lighting supply and secondary circuit, per NEC 600.31 (1000 Volts or less) &NEC 600.32 (over 1000 Volts)- Floating building feeders and services, per NEC 553.7(B)- Service entrances, up to 6 feet in length per NEC 230.43 (15)- Agricultural buildings, per NEC 547.5- Motor leads, per NEC 430.145(B)- Swimming pools, spa and hot tub motors, per NEC 680.21 (A)(E) & 680.42(A)(1)

Û For certain locations:- For exposed or concealed locations- Under raised floors in data processing areas per NEC 645.5(D) and 645.5(D)(2)- For use in lengths longer than 6 feet, per NEC 356.10(5)- Hazardous locations: where necessary for flexible connections, in accordance with the following:1. Class 1, Div. 2 - NEC 501.10(B)(2) & 501.30(B)2. Class 2, Div. 1 - NEC 502.10(A)(2) & 502.30(B)3. Class 2, Div. 2 - NEC 502.10(B)(2)4. Class 3, Div. 1 - NEC 503.10(A)(2) & 503.30 (B)5. Class 3, Div. 2 - NEC 503.10(A)(2)

Û For certain conditions:- For extreme oil and solvent environments- Where conditions of installation, operation maintence require flexiblity, and/or protection from liquids, vapors,solids, weather- For the installation and protection of electrical conductors in circuits of 600 Volts or less

Ultratite® NMORLIQUIDTIGHT FLEXIBLE CONDUIT

Page 46: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

97

SIZE(INCHES)

APPROXIMATEWEIGHT

(LBS/100 FT)

INNER DIAMETERMIN./MAX.(INCHES)

OUTER DIAMETERMIN./MAX.(INCHES)

0.690 / 0.7100.820 / 0.8401.030 / 1.0501.290 / 1.3151.630 / 1.6601.865 / 1.9002.340 / 2.375

APPROX.INSIDEBEND DIAMETER

(INCHES)

445681012

3/81/23/41

1-1/41-1/2

2

0.484 / 0.5040.622 / 0.6420.820 / 0.8401.041 / 1.0661.380 / 1.4101.575 / 1.6002.020 / 2.045

Ultratite®NMOR

LIQU

IDTI

GH

TFL

EXIB

LEC

ON

DU

IT

10.5131827344564

3/43/8 1/2 1 1-1/4 1-1/2 2

250FTREEL400FTREEL600FTREEL1000FTREEL

50FTCOIL100FTCOIL150FTCOIL

WEIGHTS AND MEASUREMENTS

PACKAGING

Page 47: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Continously interlocked steel armorÛ Solid or stranded THHN/THWNÛ Solid TFN or stranded TFFN conductorsÛ Approved Lock-nut or Snap-in fittings for easy and hassle free hook-upsÛ 6‰ conductor leads at each endÛ 1/2‰ stripped insulationÛ Complete assembly, ready to install, from the factory

HOW ITÊS CERTIFIEDÛ Lite-Whip® is UL Listed under the Wiring Assemblies (QQYZ) category.

98

Û Lite-Whip: Pre-AssembledFixture Whips

Û 600 Volts

HOW ITÊS USEDÛ For connecting fluorescent lay-in fixtures and incandescent fixtures to suspended and accessible ceilings

Lite-Whip®

PRE-ASSEMBLED FIXTURE WHIPS

Page 48: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

LOCK-NUT FITTINGS WITH SOLID THHN/THWN OR TFN CONDUCTORS

99

PARTNUMBER

WIRE SIZE# OF COND. /SIZE

CONDUCTORTYPE

CARTON PACKAGEQUANTITY/WEIGHT

BARREL PACKAGEQUANTITY / WEIGHT

WEIGHTS AND MEASUREMENTS

LWL183LWL184LWL143LWL144LWL123

SOLIDSOLIDSOLIDSOLIDSOLID

30 UNITS/23 lbs30 UNITS/24 lbs30 UNITS/25 lbs30 UNITS/26 lbs30 UNITS/30 lbs

100 UNITS/80 lbs100 UNITS/84 lbs100 UNITS/85 lbs100 UNITS/90 lbs100 UNITS/95 lbs

Lite

-Whi

PRE-ASSEM

BLED

FIXTURE

WHIPS

3x # 18 AWG4x # 18 AWG3x # 14 AWG4x # 14 AWG3x # 12 AWG

LWL183LWL184LWL143LWL144LWL123

SOLIDSOLIDSOLIDSOLIDSOLID

30 UNITS/23 lbs30 UNITS/24 lbs30 UNITS/25 lbs30 UNITS/26 lbs30 UNITS/30 lbs

100 UNITS/80 lbs100 UNITS/84 lbs100 UNITS/85 lbs100 UNITS/90 lbs100 UNITS/95 lbs

3x # 18 AWG4x # 18 AWG3x # 14 AWG4x # 14 AWG3x # 12 AWG

LWL183SLWL184SLWL143SLWL144SLWL123S

STRANDEDSTRANDEDSTRANDEDSTRANDEDSTRANDED

30 UNITS/23 lbs30 UNITS/24 lbs30 UNITS/25 lbs30 UNITS/26 lbs30 UNITS/30 lbs

100 UNITS/80 lbs100 UNITS/84 lbs100 UNITS/85 lbs100 UNITS/90 lbs100 UNITS/95 lbs

3x # 18 AWG4x # 18 AWG3x # 14 AWG4x # 14 AWG3x # 12 AWG

SNAP-IN FITTINGS WITH SOLID THHN/THWN OR TFN CONDUCTORS

SNAP-IN FITTINGS WITH STRANDED THHN/THWN OR TFN CONDUCTORS

COLOR CODING

234

STANDARD COLORS 120/208Y OPTIONAL COLORS 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

#OFCONDUCTORS

Grounding Conductor is Green.

Page 49: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

HOW ITÊS MADEÛ Non-Metallic conduit with 2 different PVC materials that form the highly flexible productÛ A rigid material forms the stiff helical spring which is encapsulated by a second flexible compoundÛ Has stranded copper THHN/THWN conductorsÛ 12‰ wire leads are exposed at each end for hassle-free hook-ups with 1/2‰ stripped insulation

HOW ITÊS CERTIFIEDÛ Ultra-Whip® is UL Listed under the Wiring Assemblies (QQYZ) category. Ultra-Whip®complies with NEC Article 356,UL Standard 1660, and CSA Standard C22.2 No. 227.2 for Liquidtight Flexible Non-Metallic Conduit. The fittingsmeet UL Standard 514B, CSA Standard C22.2 No. 18 and NEMA FB-1.

100

Û NM: Non-MetallicÛ 600 VoltsÛ Resistant to Rust, Cracksand Separation

Û Intended for 208/240/480Volt Single Phase Circuits

Û Non-Metallic Raceway isNon-Conducting

HOW ITÊS USEDÛ For connecting air conditioners, pumps, motors, compressors, swimming pool devices and other similar equipmentÛ For electrical applicationsÛ Complete assembly, ready to install, from the factory

Ultra-Whip® NMPRE-ASSEMBLED HOOK-UP WHIPS

Page 50: SOUTHWIRE’S MCAP · SOUTHWIRE’S MCAP® Southwire'spatentedinnovationwillsavecontractorsupto30percentin installationtimeandcosts.ThisUL-listedandNECcompliantproductreplaces

METAL CLAD& CONDUIT

101

PARTNUMBER

SIZE(INCHES)

WIRE SIZE# OF COND. /SIZE

AMPERE RATING(AMPS)

MASTER CARTONQUANTITY

(# OF PIECES)

MASTER CARTONWEIGHT(LBS.)

303040

40

666

6

121314

15

R124R126R344

R346

3x #10 AWG3x #10 AWG2x #8 AWG

1x #10 AWG Ground2x #8 AWG

1x #10 AWG Ground

1/2‰1/2‰3/4‰

3/4‰

234

STANDARD COLORS 120/208Y OPTIONAL COLORS 277/480YBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREYBROWN, ORANGE, YELLOW, PURPLE, GREY

BLACK, WHITEBLACK, WHITE, REDBLACK, WHITE, RED, BLUE

#OFCONDUCTORS

Grounding Conductor is Green.

3/4‰ R3441/2‰ R124 1/2‰ R126 3/4‰ R3464FT.

6 FT.

Ultr

a-W

hip

®N

MPR

E-A

SSEM

BLED

HO

OK-

UP

WH

IPS

WEIGHTS AND MEASUREMENTS

COLOR CODING

PACKAGING