SD- ribbed bearing
With test report for sound damping of impact noise. Sound damping bearing underneath flight of
stairs, floors, joint stems etc. help to separate subsonic noise and impact sounds in residential buildings,
offices and hospitals. Profiled, non-reinforced elastomer bearings are especially suitable in this case due
to their soft absorption qualities.
A part from sound absorption, they also ensure a controlled load distribution and prevent excessive edge
compression and spalling at the components. Improvement in evaluated impact noise protection is at
least 27 dB for compressions between 0.1 and 1.0 N/mm² as compared to a rigid support. 31 dB is
attained at 0.3 N/mm² compression.
Sound damping of impact noise
SD-ribbed bearing
SD-ribbed bearing
3
M e m b e r o f B e s a g r o u p
R
M e m b e r o f B e s a g r o u p
R
21
Sound damping bearingType SD-ribbed bearing
Supply: as roll 10 m long, 200 mm width or cutted on demand.
The profil is notched. This allows a separating in 50 or 100 mm wide stripes.
SD-ribbed bearing
Separating notch each 50 mm
© Leschuplast GLT
-
22
M e m b e r o f B e s a g r o u pM e m b e r o f B e s a g r o u p
R
Sound damping of impact noise
Sound damping bearingType Z, TD 21 SD, Type B
Type Z TD 21 SD
The sound damping elements type Z, type B and TD 21 SD include the high reduction of impact noise of
the Leschuplast GLT SD-ribbed bearing and ensure, that no dirt reduces the function of sound damping.
Caused by the notches type Z might be fitted to the situation on site easily. Not needed parts of the foam
might be cutted of. Special dimensions might be produced on demand.
1000 mm
550 mm
1200 mm
centr
al are
a
ca. 3
50 m
m
Leschuplast GLT SD-ribbed bearing50 x 10 mm
10 mm
90 mm
up to
first no
tch
1000 mmor
1200 mm
120 m
m
Leschuplast GLT SD-ribbed bearing50 x 10 mm
7 notches10 mm each
Sound damping element type B for stairs (350 x 1000 mm)
© Leschuplast GLT © Leschuplast GLT
-
Summary of sound damping test of the SD-ribbed bearing
The Leschuplast GLT SD-ribbed bearing can be used in a wide pressure load range from 0.1 N/mm² to 1.0 N/mm² due to excellent sound absorption properties. In this case, evaluated impact noise reduction of at least 27 dB is achieved. An evaluated impact noise reduction of 31 dB is attained with an optimum design at a pressure load of 0.3 N/mm².
M e m b e r o f B e s a g r o u p
R
3
M e m b e r o f B e s a g r o u p
R
M e m b e r o f B e s a g r o u p
R
23
Sound damping bearingType SD-ribbed bearing
40
35
30
25
20
10
5
0
0 0,1 0,3 0,5 0,7 1,0 1,2
L w in dB
29 272830
31
15
N/mm²
Eva
luate
d im
pact
nois
e r
educt
ion
Pressure load in N/mm² on the bearing
Test report : Nr. 1440-001-13 on 24.04.2013 SG-Bauakustik, Institut für schalltechnische Produktoptimierung
Specification: sound damping bearing ........ mm width, thickness 10 mm, with sound damping core, width ........ mm, with test report about an impact sound insulation up to 31 dB, supply and correct technical setting. Leschuplast GLT type TD 21 SD
Specification: sound damping bearing ........ mm width, thickness 10 mm, with test report about an impact sound insulation up to 31 dB, supply and correct technical setting. Leschuplast GLT type SD-ribbed bearing
Specification: sound damping bearing ........ mm width, thickness 10 mm, with sound damping core, width ........ mm, with test report about an impact sound insulation up to 31 dB, supply and correct technical setting. Leschuplast GLT type Z
Specification: sound damping bearing ........ mm width, thickness 10 mm, with sound damping core, width ........ mm, with test report about an impact sound insulation up to 31 dB, supply and correct technical setting. Leschuplast GLT type B
© Leschuplast GLT