FV 70 TACOSOL 4.0 ZR
FS-FV
Description
WiththeFV70TACOSOL4.0ZRSolarstation,hydraulicbalancing,flowmea-surementandventingcanbeperformeddirectlyinthestation.
Thebuilt-inSETTERInlineUNallowstherequiredquantityoffluidinthepri-marycircuittobeexactlyandsimplysetandchecked.
Thecontinuousventingsystemmeetsthemostdemandingrequirementsandkeepsthesystemfreeofair.
Systemswhicharecorrectlybalancedhydraulicallyandair-freeguaranteeop-timalenergyextraction,andarethusmorecost-effectiveinthesenseoftheenergy-savingdirectiveslaiddownbylaw.
Usingthescale,whichispre-calibratedforantifreeze,thetechniciancansetandchecktheexactflow-ratevalueson-site.
Neithertrainingcoursesnorexpensivemeasuringdevicesarerequired.Installationandventingcanbecarriedoutbyonepersonworkingunassisted.
Installation position
Thesolarstationmustbeinstalledverticallytoensureproblem-freefunctioningoftheventingunit.
Operation
Theflow-ratemeasurementisbasedontheprovenprincipleofabafflefloat.
Thebasisfortheairventingarespecialflowtechnologymeasureswhichaccu-mulatetheairinthetopoftheventingspace,fromwhereitcanbereleasedfromtimetotime.
Therearenomechanicalparts,sothedesignensuresalongservicelife.Atthesametime,actsasacheckonwhetherairisbuildingupinthesystem.
Advantages
• Cost-effectiveinstallationandfilling(canbeperformedbyonepersonworkingunassisted)
• Multi-functionalballvalve,whichgreatlysimplifiesthefillinganddrainingofthesystem
• Collectorandreservoirsectionscanbeseparatedforinstallationwork
• Straightforwardpumpreplace-ment(suctionandpressuresidecanbeshutoff)
• Preciseandrapidregulationadustments,requiringnodiagrams,tablesorexpensivemeasuringdevices
• FunctioncheckingusingthedirectflowrateindicatorintheSETTERInlineUN
• Visualscaleinl/minpre-calibratedforglycolmixesυ=2.3mm²/s
• Constantairreleasewhilesystemisrunning
• Straightforwardventingdirectlyinthestation
• Possibilityforintegrationofcontrollers
• Reliableoperation,andlowmaintenance
• Ruggeddesign
Solar station
Pump, regulator and air venting unit in solar heating systems
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
FV 70 TACOSOL 4.0 ZR
Ø12,5
21
3 4
5
6
310
147
50
3137
430
3015
13
27
83 74
7729
0
435
== 409812587
153
270.1506.000 1,5– 6,0l/min 1,5 6,0 WILOST20/6-3270.1516.000 4,0–16,0l/min 3,3 6,0 WILOST20/6-3270.1528.000 8,0–28,0l/min 3,5 6,0 WILOST20/6-3
270.1506.356 1,5– 6,0l/min 1,5 6,0 WILOST20/6-3270.1516.356 4,0–16,0l/min 3,3 6,0 WILOST20/6-3270.1528.356 8,0–28,0l/min 3,5 6,0 WILOST20/6-3
Dimensions
1 MalethreadISO228,G1"(linefromthecollector)2 MalethreadISO228,G1"(linetothecollector)3 MalethreadISO228,G1"(linetothereservoir)4 MalethreadISO228,G1"(linefromthereservoir)5 MalethreadISO228,G¾"(expansionvesselline)6 FemalethreadDIN2999/ISO7,Rp¾"(safetyvalveblow-offline)
Specification text
TACOSOL4.0ZRisaready-to-connectsolarstationforcirculationandventingofsolarcircuitmediumwithmountingattachments.
WithintegratedSETTERInlineUNregulatingandcheckvalvewithdirectindicationofthesetflowrateinl/min.
Metallicnon-returnvalvesintegratedinbothballvalves.
Optimizedforuseinsolarapplications.Measuredvalueswithmediumviscosityυ=2.3mm²/scanbereaddirectlyatthesightglassduringadjustmentwith-outtheneedfortables,diagramsormeasuringdevices.
Technical data
Max.operatingtemperature:−Flowcircuit(ventingside):160°C−Returncircuit(pumpside):110°C
Max.operatingpressure:8bar−Safetyvalveresponsepressure:6bar
kVSvalueandmeasurementrangeaspertable«TypeProgram».
Material:Ventpipe:PaintedsteelValvehousingcomponents:BrassInternalcomponents:Stainlesssteel,brassandplasticSightglass:BoricsilicateO-ringseals:EPDMInsulatingmaterial:EPP
Flatsealswithhightemperatureresistancesuitableforuseinsolarapplications
ThreadaccordingtoDIN2999/ISO7andISO228
MeasuringaccuracySETTERInlineUN:±10%(ofthehighestnominalvalue)
Fluids
• Waterandproprietaryadditivesusedagainstcorrosionandfreezing(displayscaleformediumviscosityυ=2.3mm²/s)
• Heatingwater(VDI2035)
• Coldwater
Type Program
TACOSOL 4.0 ZR, dual phase design Version with cover plate
Includes:flowphase(ventingside)andreturnphase(pumpside)
Order no. Measuring range 3) kVS 1) kVS 2) Circulation pump
1)kVS[m³/h]withυ=1mm²/sinthereturnphase(pumpside)2 )kVS[m³/h]withυ=1mm²/sintheflowphase(ventingside)3 )Visualscaleforwater/glycolmixwithυ=2,3mm²/s
TACOSOL 4.0 ZR, dual phase design Version with carrier for controller
Includes:flowphase(ventingside)andreturnphase(pumpside)
Order no. Measuring range 3) kVS 1) kVS 2) Circulation pump
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
FV 70 TACOSOL 4.0 ZR
Wall mounting
Thesolarstationcanbemountedonthewallusingthewelded-onbaseplatewithmountingbracket.Thebracketcanberemovedfromthebaseplateandsecuredtothewallforeaseofmounting.Themountingaccessoriesaresuppliedintheinsulation:-2hexagon-headedwoodscrews,8x50mm-2washers-2mountingdowels,10x50mm-Assemblyandcommissioninginstructions-Operatingandsafetyinstructionsforthecirculationpump
Flow circuit components (venting side)
Stop ball valve with safety valve (and integrated non-return valve)
Theballvalveallowstheflowcircuitlinetobedividedbetweenthecollectorandtheheataccumulator.Asrequiredbysafetyregulations,theconnectionbetweenthecollectorandsafetyvalveisnotinterruptedinanyoftheballvalvepositions.Anintegratedcheckvalvestopsthemediumflowingintheoppositedirectionandalsoactsasagravitybrake.Thesafetyvalvethusprotectsthesystemcomponentsagainstexcessiveoverpressureinalloperatingphases.Holesareprovidedinthehandleoftheballvalvesothatitcanbesealedtoprotectagainstunintentionalclosing.Thispreventsunintentionaldisconnec-tionoftheconnectinglinebetweenthecollectorandtheexpansionvesselatthispoint.
Venting tank with bleeder valve
Thepurposeoftheventingtankistoremoveairfromthemediumflowingthroughthetank.Theventingtankcanholduptoapprox.2.5dlofairandhasableedervalveforreleasingtheair.Thefrequencyandquantityofthecollectedaircanbeusedtochecktheleaktightnessofthesystem.
Pressure gage
Thepressuregagewitharangefrom0to10barindicatesthesystempressure.
Thermometer
Thethermometerwitharangefrom0to160°Cconstantlyindicatesthemediumtemperatureintheflowcircuit.Thetemperatureisrecordeddirectlyinthemediumtominimizethereactiontime.Thesensorisinsertedinaprotectivepipesothatitcanbeexchangedwithouthavingtoemptythesystem.
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
Return circuit components (pump side)
Stop ball valve with fill and drain cock and integrated check valve
Theballvalveallowsthereturnlinetobesplitbetweenthecollectorandtheheataccumulator.Thespecialballcockdesignprovidesvariousfunctions.Ifthehandleispointinginthedirectionofflowthesystemmediumcancir-culate.Anintegratedcheckvalvestopsthemediumflowingintheoppositedirectionandalsoactsasagravitybrake.Turningthehandle90°totherightclosestheballcockinthedirectionofthemediumflowandallowstheuppersystempart(collector)tobefilledandemptiedusingthefillanddraincock.Turningthehandle90°totheleftclosestheballcockinthedirectionofthemediumflowandallowsthelowersystempart(reservoir)tobefilledusingthefillanddraincock.AmalethreadG¾"isprovidedonthefillanddraincockforconnectingahose.Holesareprovidedinthehandleoftheballvalvesothatitcanbesealedtoprotectagainstunintentionalclosing.
WILO ST 20/6-3 circulation pump, solar version
Thiscirculationpump,includedasstandardinthescopeofdeliveryandinte-gratedintheTACOSOL,coversalargedeliveryrange.Therequiredoperatingpointcanbepreselectedusingoneofthethreelevels.Adefectivepumpcanbereplacedwithouthavingtoemptythesystemusingthestopcocksonthesuctionside(SETTERInlineUN)andthepressureside(ballvalve).
SETTER Inline UN balancing valve
Precisionadjustmentatthebalancingvalveallowstherequireddeliveryquantitytobeadaptedtosystemrequirements.TheprovencombinationofbalancingvalveandflowindicatorinonehousingintheTaconovabalancingvalvesmeansthatnoadditionalmeasuringcomponentsarerequiredfortheSETTERInlineUN.Flowrateindicationisconstant,i.e.theadjustmentcanbeimmediatelyverifiedbymeansviatheflowrateindicator.Theindicatorispre-calibratedforamediumviscosityof2.3mm²/s.Thisdoesawaywiththeneedforcorrectioncurves.Theconnectionflangeontheoutletsideisdirectlyscrewedontothe1½"pumpconnectorfittingswhichmeanstherearenoseallocationsforfurtheradaptercomponents.
Connector MAG
TheconnectorfittingwithG¾"connectingthreadfortheexpansionvesselisconnectedinserieswiththecirculationpump.Thisarrangementpreventsnegativeworkingpressureconditionsinevencriticalsystemsandavoidsreductionsintheworkingpressure,oneofthemaincausesofearlyevapora-tionofthemedium.
Thermometer
Thethermometerwitharangefrom0to160°Cconstantlyindicatestheme-diumtemperatureoftheflowcircuit.Thetemperatureisrecordeddirectlyinthemediumtominimizethereactiontime.Thesensorisinsertedinaprotectivepipesothatitcanbeexchangedwithouthavingtoemptythesystem.
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
270.1516.000 4...16 l/min
1000
100
10
1
A
B
C
D
V
kvs=6,0
kvs=3,3
1 4 16 10010
DN 20 – 1"270.1506.000 1,5...6 l/minDN 20 – 1"
1000
100
10
1
0,1
A
BCD
V
kvs=6,0
kvs=1,5
1 1,5 6 10
270.1528.000 8...28 l/min
1000
100
10
1
B
C
D
V
kvs=6,0
kvs=3,5
1 8 28 10010
DN 20 – 1"
FV 70 TACOSOL 4.0 ZR
Returncircuitcharacteristic:A-D=ValvepositionSETTERInlineUN
Returncircuitcharacteristic:B-D=ValvepositionSETTERInlineUN
Returncircuitcharacteristic:A-D=ValvepositionSETTERInlineUN
Flowcircuitcharacteristic:V(Ventingphase)
Flowcircuitcharacteristic:V(Ventingphase)
Flowcircuitcharacteristic:V(Ventingphase)
Pre
ssu
re d
rop
in m
bar
Pre
ssu
re d
rop
in m
bar
Pre
ssu
re d
rop
in m
bar
Flow in l/min
Flow in l/min
Flow in l/min
Pressure loss diagrams
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
FV 70 TACOSOL 4.0 ZR
(energieControlcontrolleralsointegrable,notincludedinourrange)
Accessories VF 10 soldered fittings
Fittingconsistingofsolderedconnectorfitting,unionnutandflatsealsuitableforuseinsolarapplications,2piecesperset.
Order no. G x mm Version for210.5331.019 1"x18mm coppertube18mm210.5332.019 1"x22mm coppertube22mm
FX 96 MAG mounting bracket with quick coupling
Formountingtheexpansionvesselonthewall.Quickcouplingwithcut-off,1xfemalethread,1xmalethreadG¾".
Order no. DN G296.7002.000 20 ¾"
FX 96 KFE 3-way connector
ForconnectiontotheMAGconnector.ConsistingofT-piecewithKFE(fillanddraincock),unionnut,G¾"femalethreadwithflatsealsuitableforsolarapplications,G¾"malethreadedconnection.
Order no. DN G296.7001.354 20 ¾"
FX 96 stainless steel tube
Forconnectingtheexpansionvessel.Includes¾“unionnutandflatsealssuitableforsolarapplications.
Order no. DN G Length296.7003.000 20 ¾" 0,5m
FX 96 Solar controller RESOL DeltaSol®(seeseparatedatasheet)
Order no. Type Application296.7010.000 BS basicsolarsystems296.7011.000 BSPlus complexsolarsystems
FX 96 Solar controller SOREL
Order no. Type Application296.7012.000 TDC1 basicsolarsystems296.7013.000 TDC3 complexsolarsystems
FX 96 carrier for controller
Order no. Application296.7020.000 TACOSOL4.0ZR
FX 96 cover plate
Order no. Application296.7021.000 TACOSOL4.0ZR