SOLAR-MOUNT-RESIDENTIAL PHOTOVOLTAIC POOL PUMP … · situs: 1211 ne 28 avenue, pompano beach, fl...
Transcript of SOLAR-MOUNT-RESIDENTIAL PHOTOVOLTAIC POOL PUMP … · situs: 1211 ne 28 avenue, pompano beach, fl...
PUMP
PUMP PLUSOPTIONALHEATING ORACCESSORYEQUIPMENT
RETURN TO POOLFR
OM
PO
OL
LORENTZP S600BADU PUMP
MOUNT DETAILS SHOWNON THIS PLAN. INSTALLPER OEM INSTRUCTIONS
PV CONTROLLERLIGHTNINGARRESTOROPTIONAL
+
+ + +
3 MODULS IN 1 ARRAY
PV MODULE PV MODULE PV MODULE
J BOX
ATTACH TO ROOF FRAMINGMEMBER WITH 2 LAG BOLTSEACH STANDOFF
4'-0" 4'-0"
3'-0"
PZ2
PZ2
PZ3
PZ1
DN
4/1
°
SOUTH EAVE
HIP
RIDGE
1 STORY RESIDENCE 3 PV MODULES 4/12 TILE ROOF
SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN: CHECKED:SB AG
EN
LAR
GE
D V
IEW
ING
& H
YP
ER
LIN
KS
:P
RIN
T V
ER
SIO
N O
F T
HIS
PLA
N P
RO
VID
ES
MIN
IMU
M I
NF
OR
MA
TIO
N N
EE
DE
D B
Y U
SE
RS
.
ELE
CT
RO
NIC
VE
RS
ION
(E
V)
PR
OV
IDE
S M
AG
NIF
IED
VIE
WIN
G U
P T
O 6
40
0%
. E
V A
LSO
PR
OV
IDE
S H
YP
ER
LIN
KA
CC
ES
S T
O O
EM
MA
NU
ALS
AN
D A
BU
ND
AN
T O
TH
ER
SU
PP
LEM
EN
TA
RY
IN
FO
RM
AT
ION
.EV
MA
Y B
E
AC
CE
SS
ED
AT
: W
WW
.GE
ZE
LMA
NP
E.C
OM
/PV
/0
31
8P
.BS
_K
ien
Po
olP
um
p_
Po
mp
an
o_
FL.
dw
g
REVISIONS:
03SCALE: NTS
SAMPLE INSTALLATION PHOTOS
I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECTMAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.
CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!
C
OP
Y R
IGH
T &
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
ICE
•T
HIS
PLA
N S
ET
IS
CO
PY
RIG
HT
PR
OT
EC
TE
D A
ND
CO
NT
AIN
S I
NT
ELL
EC
TU
AL
PR
OP
ER
TY
WH
ICH
BE
LON
GS
TO
ALL
EN
GE
ZE
LMA
N P
E.
•A
CC
ES
S I
S G
IVE
N T
O T
HE
IN
FO
RM
AT
ION
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OS
E O
F C
OM
PLE
TIO
N O
F T
HE
PR
OJE
CT
FO
R W
HIC
H I
T I
S I
NT
EN
DE
D.
•N
O O
TH
ER
US
E M
AY
BE
MA
DE
OF
TH
E I
NF
OR
MA
TIO
N,
DR
AW
ING
S,
OR
ID
EA
S H
ER
EO
N W
ITH
OU
T T
HE
EX
PR
ES
S,
WR
ITT
EN,
PE
RM
ISS
ION
OF
ALL
EN
GE
ZE
LMA
N P
E
ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC
C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC
C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF
THIS PLAN IS ONLINE FOR REVIEW @
WWW.GEZELMANPE.COM/PV/0318P.BS_KIENPOOLPUMP_POMPANO_FL.PDF
CO
NT
AC
T D
ES
IGN
TE
AM
@
ww
w.G
eze
lma
nP
E.c
om
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM
www.GezelmanPE.com
I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE CURRENTFLORIDA BUILDING CODE
INS
TA
LLA
TIO
N O
F A
RO
OF
MO
UN
T
PH
OT
OV
OLT
AIC
PO
OL
PU
MP
SY
ST
EM
TH
E
KIE
N
RE
SID
EN
CE
VULT 170_MPH, VASD 131.7 MPH
EXPOSURE: C, RISK CATEGORY: II, PZ2 WIDTH 3-FT
WORSE CASE WIND FORCES; UPLIFT, NEGATIVE, PSF, PZ1-32, PZ2-54.5, PZ3-83.4_PSFCO
DE
VE
RIF
Y
MODULE# SHARP ND 240 QCJ, FSEC: #SH11-NT90-0616
DESIGNED PER: ASCE 7-10, FBC 2010
WIN
D
01SCALE: 1/4" = 1'-0"
ROOF LAYOUT PLAN
AHJ: BROWARD COUNTY, PARCEL ID# 4843 30 21 0940
SIT
US
: 1
21
1 N
E 2
8 A
VE
NU
E,
PO
MP
AN
O B
EA
CH
, F
L
STRUCTURAL LOAD FROM EQUIP < 4PSF
10.21.2013
OWNER OF RECORD:
1211 NE 28 AVE POMPANO BEACH FL 33062-3822
KIEN,F MICHAEL
PV POOL PUMP STRUCTURAL INSTALLATION NOTES -ELECTRICAL DESIGN BY CONTRACTOR.
INSTALLATION SHALL BE MADE USING UNIRAC STANDARD RAILS INSTALLED PER OEM
INSTRUCTIONS HTTP://WWW.UNIRAC.COM/PDF/II227.PDF AND DRAWING FIGURES THIS PLANSHEET.
RAILS SHALL BE CONNECTED WITH L-FEET ON TOP OF STAND-OFFS SOLIDLY ATTACHED INTO
ROOF FRAMING ON 4-FT CENTERS USING MINIMUM 5/16-INCH DIAMETER CRS (CORROSIONRESISTANT STEEL) LAGS OF SUFFICIENT LENGTH TO ACHIEVE MINIMUM OF 3-INCH EMBEDMENT.A GENEROUS PUDDLE OF FLORIDA PCA ROOF SEALANT BETWEEN STANDOFF AND ROOFCOVERING IS ADEQUATE WATERPROOFING. CONTRACTOR IS FREE TO CHOOSE ALTERNATEMETHOD ACCEPTABLE TO AHJ (AUTHORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT).
EACH PV MODULE SHALL BE SUPPORTED BY TWO RAILS AND SHALL ATTACH THERETO ATCROSSING POINTS (4-PER MODULE). ADJACENT MODULES MAY SHARE ATTACHMENTS TO RAIL.
04SCALE: NTS
PV MODULE DATA SHEET09
SCALE: NTS
FLAT OR BARREL TILE ATTACHMENT - MOUNTING SYSTEM- UNIRAC.COM
10SCALE: NTS , THESE PICTURES ARE TYPICALL INSTALLATIONS
SAMPLE INSTALLATION PHOTOS
DETAILS MAY VARY - CURRENT OEM INSTRUCTIONS PREVAILHTTP://WWW.UNIRAC.COM/RESIDENTIAL/RESIDENTIAL-PRODUCTS/SOLAR-MOUNT-RESIDENTIAL
UNIRAC CODE COMPLIANT LETTER - FLORIDA:
THIS PV POOL PUMP PLAN WILL PROVIDE ADEQUATE PUMPING CAPACITY TO
SATISFY THE REQUIREMENTS OF A SOLAR POOL HEATER FOR A TYPICAL RESIDENTIAL
POOL IN CONJUNCTION WITH MY PLANS http://www.cadvice.us/sw/AS.2.2.PH.pdf
& http://www.cadvice.us/sw/AS.2.2.PH_FSM.pdf
BIG POOLS, POOLS WITH SPECIAL CLEANING APPARATUS, POOLS WITH HIGH
BACK-PRESSURE FILTRATION, AND/OR NON-STANDARD HYDRAULICS WILL REQUIRE
SITE-SPECIFIC ENGINEERING. CONTRACTOR & OTHERS ARE DIRECTED TO OEM
PERFORMANCE DATA http://www.lorentz.de/pdf/lorentz_ps600_badutop_en.pdf
APPLICABLE PV MODULE & PUMP PERFORMANCE SHOULD BE CAREFULLY
CONSIDERED IN CONJUCTION WITH THE POOL PUMPING REQUIREMENTS AND
OTHER IMPORTANT SITE CHARACTERISTICS.
02SCALE: NTS
PARCEL (PROPERTY APPRAISER DATA)
SYSTEM:
UNIRAC, INC.
1411 BROADWAY BOULEVARD NE
ALBUQUERQUE NM 87102-1545
TELEPHONE: 505-242-6411
INSTALLATION LOCATION
11SCALE: NTS
ASCE 7 PRESSURE ZONE DIAGRAM
04SCALE: NTS
PV POWERED PUMP DATA SHEET04
SCALE: NTS
SYSTEM INSTALLATION DIAGRAM