SMARTONLINE® 3-PHASE UPS SYSTEMS •380Y/220V,400Y/230Vor415Y/240V
The Most Reliable and Cost-Effective Power Solutions for Your Data Center
SMARTONLINE KX2 SERIES (80-120KVA)
IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS
MODULAR ARCHITECTURE ELIMINATES DOWNTIME
SCALABLE DESIGN GROWS WITH YOUR DATA CENTER
1-TO-1 GENERATOR SIZING LOWERS INSTALLATION COSTS
EXTREME EFFICIENCY LOWERS OPERATING COSTS
SUPPORT UP TO 480 KVA IN PARALLEL
SMARTONLINE KX2 SERIES UPS SYSTEMSExtremely efficient protection for your most important equipment
IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMSOn-line, double conversion operation continuously
delivers precision-regulated, pure sine wave output,
isolating your critical systems from damaging and
disruptive power problems.
MODULAR ARCHITECTURE ELIMINATES DOWNTIMEInternal N+1 power module redundancy, parallel
capability (up to four units) and fault-tolerant bypass
features keep your critical systems highly available
and productive around the clock.
1-TO-1 GENERATOR SIZING LOWERS INSTALLATION COSTSAn advanced IGBT rectifier produces <4% THDi
(input Total Harmonic Distortion), eliminating costly
over-sizing requirements for generators, breakers
and cables.
SCALABLE DESIGN GROWS WITH YOUR DATA CENTER Models with less than 120 kVA capacity can be
expanded up to 120 kVA as infrastructure grows and
more equipment is added.
EXTREME EFFICIENCY LOWERS OPERATING COSTSEfficiency up to 97% significantly lowers power and
cooling costs compared to multiple smaller units or
legacy high-capacity units.
2
C O N T E N T S
SMARTONLINE KX2 SERIES UPS SYSTEMS
SU80KX2 80kVA/64kW
SU100KX2 100kVA/80kW
SU120KX2 120kVA/96kW
IDEAL OUTPUT POWER 3
MODULAR ARCHITECTURE 3
SCALABLE DESIGN 3
PARALLEL FEATURES 3
1-TO-1 GENERATOR SIZING 4
EXTREME EFFICIENCY 4
GREEN POWER 4
MONITORING AND CONTROL 5
BATTERY CABINETS 5
COMPACT FOOTPRINT 6
ORDERING INFORMATION 6
TECHNICAL SPECIFICATIONS 7
IDEAL OUTPUT POWERSmartOnline KX2 Series UPS Systems isolate your critical
equipment from power problems, including surges, line noise,
harmonic distortion, electrical impulses, frequency variations,
brownouts, overvoltages and blackouts. True on-line operation
continually transforms AC input power into filtered DC power,
then resynthesizes it into precision-regulated AC output with a
pure sine wave. Strong overload capacity supports up to 150%
output for up to 60 seconds. Reliable backup power with zero
transfer time to battery keeps equipment operating safely
through shorter power failures and allows time to shut down
or switch to generator power during longer outages. Rapid
recharging restores battery charge levels in as little as two
hours.
MODULAR ARCHITECTUREIntelligent, independent 20 kVA power modules provide internal
redundancy. When the UPS is configured for N+1 redundancy,
convenient hot-swap power modules can be replaced without
powering down the connected load. In the event of a power
module fault, the load is automatically distributed among
the remaining modules. Because load redistribution happens
without interrupting critical systems, mean time to recovery
is zero—far superior to legacy UPS systems. In addition,
redundant control circuits eliminate a single point of failure
commonly found in less-reliable UPS designs. Power module
installation is simple—each module is completely self-contained
and can be installed or removed in minutes using nothing
but a screwdriver.
If service or repair requires UPS shutdown, all models include
a manual bypass breaker and automatic bypass function that
maintain system availability by passing through AC power
until the UPS system returns to service.
SCALABLE DESIGNUPS systems in the KX2 Series with less than 120 kVA capacity
include empty slots to accommodate more 20 kVA power
modules. All systems can be upgraded to 120 kVA load
capacity, or six 20 kVA power modules. This scalable design
allows for capacity to be added slowly as the needs of your
data center grow, allowing more flexibility when selecting
a UPS, saving on up-front costs and facilitating
infrastructure planning.
PARALLEL FEATURESIncrease fault tolerance or quadruple output capacity by
connecting up to four SmartOnline KX2 Series UPS Systems
in parallel. If one UPS system is taken offline for maintenance,
the other UPS systems automatically compensate to
support the equipment load—without requiring
additional programming.
SmartOnline KX2 Series UPS Systems ship ready for parallel
operation. Patented dual-DSP technology provides optimal
synchronization of power sources.
External Battery Cabinet 120 kVA UPS System
100 kVALoad
20 kVARedundancy
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
MODULAR ARCHITECTUREINTERNAL N+1 REDUNDANCY
SCALABLE DESIGN GROWS WITH YOUR DATA CENTER
80 kVA UPS System
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
120 kVA UPS System
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
+ =
120 kVAUPS System
120 kVAUPS System
120 kVAUPS System
120 kVAUPS System
ExternalBattery Cabinet
80 kVAUPS System
ExternalBattery Cabinet
80 kVAUPS System
360 kVALoad
100% Support 100% Support
160 kVALoad
PARALLEL FOR N+1 REDUNDANCY
1+1 PARALLEL CAPACITY DOUBLING
ExternalBattery Cabinet
80 kVAUPS System
ExternalBattery Cabinet
80 kVAUPS System
100% Support 100% Support
160 kVALoad
PARALLEL TO MAXIMIZE CAPACITY
1+1 PARALLEL CAPACITY DOUBLING
120 kVAUPS System
120 kVAUPS System
120 kVAUPS System
120 kVAUPS System
480 kVALoad
Four 120 kVA SmartOnline KX2 Series UPS Systems can provide backup power for a 480 kVA load.
Four 120 kVA SmartOnline KX2 Series UPS Systems can provide redundant backup power for a 360 kVA load.
In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system. For example, a 120 kVA UPS is configured for N+1 redundancy when the connected load is 100 kVA or less.
SMARTONLINE KX2 SERIES UPS SYSTEMS
3
KX2 models with less than 120 kVA capacity can be expanded up to 120 kVA as infrastructure grows and more equipment is added.
1-TO-1 GENERATOR SIZINGSmartOnline KX2 Series UPS Systems
have a generator-friendly design that
decreases installation costs. A high input
power factor and IGBT rectifier with DSP
control create less than 4% input Total
Current Harmonic Distortion (THDi).
Low Current THDi enables cost-
saving 1-to-1 sizing of UPS systems to
generators, allows generators to run
cooler and extends the operational
lifespan of all input components.
Low Current THDi also reduces sizing
requirements for cables and breakers
and improves reliability by eliminating
nuisance breaker tripping and
overheated transformers.
2900
2601
17631
2
3
4
5
1581
5800
5202
3525
3162
8700
7803
5288
4743
11599
14499
13005
8813
7904
10404
7050
6323
CUMULATIVE ENVIRONMENTAL IMPACT OVER FIVE YEARS
Legacy UPS Energy Usage (MWh)
SmartOnline UPS Energy Usage (MWh)
Legacy UPS Carbon Emissions (Metric Tons)
SmartOnline UPS Carbon Emissions (Metric Tons)
GREEN POWEREfficient SmartOnline
KX2 Series UPS Systems
save energy and reduce
your carbon footprint.
Replacing 240 kVA of
legacy UPS capacity
can reduce CO2 emissions by 182 metric
tons and save 300 megawatt-hours* of
electricity per year—enough to power
24 single-family homes.
An extremely wide voltage correction
range reduces battery wear up to 40%,
so batteries last longer. Batteries are also
recyclable and contain a high percentage
of recycled materials, creating an efficient
manufacturing loop that conserves
resources and reduces landfill waste.
Tripp Lite also restricts
hazardous substances during
manufacture, maintaining
industry leadership in RoHS
compliance.
* 1 megawatt-hour = 3,6 gigajoules.
EXTREME EFFICIENCYAdvanced high-utilization IGBT inverter technology and high-speed DSP control
provide superior operating efficiency at all load levels—up to 97% in economy mode.
Increasing efficiency lowers UPS system operating costs by reducing electricity
consumption, heat emissions and cooling costs. Replacing up to 480 kVA of legacy
UPS capacity with SmartOnline KX2 UPS Systems can save more than US $60 000
per year.
In addition, SmartOnline KX2 Series UPS Systems automatically correct the widest
range of incoming voltages in their class. The wide voltage acceptance window and
temperature-compensated charging combine to decrease battery wear significantly,
extending service life and reducing replacement costs.
SmartOnline KX2 Series UPS Systems reduce installation
costs up to 30% versus legacy UPS systems.
INSTALLATION COST COMPARISON
Generators
Cabling
Breakers
Related Costs
Cost
Smar
tOnl
ine
KX
2Le
gac
y U
PS
Replacing 240 kVA of legacy UPS capacity with SmartOnline KX2 Series UPS Systems
can save 300 megawatt-hours* and reduce CO2 emissions by 182 metric tons
(enough to offset 3 000+ flights from London to Paris) per year.
4
Convenient communication and
management features allow you
to monitor power conditions,
receive automatic alerts and
control SmartOnline KX2 Series
UPS Systems with drift-proof digital
precision from any distance.
• CONTACTCLOSUREINTERFACE
Connects to an Emergency Power
Off (EPO) circuit for emergency
UPS system shutdown. Also allows
the UPS system to monitor
external battery cabinets and
communicate operational
messages.
• RS-232SERIALPORT
Connects to a server for shutdown
commands and reporting through
PowerAlert software (included).
• ACCESSORYCARDSLOT
Optional network card
(SNMPWEBCARD) provides
remote monitoring and control.
Optional environmental sensor
(ENVIROSENSE) monitors
temperature, humidity
and more.
• NETWORKPOWER
MANAGEMENT
You can manage UPS systems with
PowerAlert Network Management
System (included) or a third-party
network management system.
• LED/LCDCONTROLPANEL
Offers convenient push button
control and communicates
operational modes,
conditions and warnings.
BATTERY CABINETSAll SmartOnline KX2
Series UPS Systems
require an external
battery cabinet.
Additional battery
cabinets can be
connected to expand
runtime.
Real-Time Power Status Consoles
PowerAlert allows you to manage hundreds of UPS systems from a single workstation.
MONITORING AND CONTROL
BP480V55
The LED/LCD control panel provides detailed UPS status information.
5
POWERALERTNETWORKMANAGEMENTSYSTEM
LED/LCDCONTROLPANEL
The rear panel includes several communication interfaces.
NETWORKCONTROLINTERFACESNMPWEBCARD Slot
Input Dry Contact Interface
Parallel Configuration
Port
Parallel Configuration
Port
DIP Switches
RS-232 Serial Port
Output Dry Contact Interface
COMPACT FOOTPRINTEach SmartOnline KX2 Series UPS System provides more than
sufficient power for multiple racks of equipment while maintaining
a compact footprint, saving valuable data center floor space for
critical systems and cooling. Wall-mounted distribution and
bypass panels do not require additional floor space.
ORDERING INFORMATION
MODEL OUTPUT CAPACITY NOMINAL INPUT/OUTPUT VOLTAGE BATTERY CONFIGURATION
SU80KX2 80kVA/64kW 380Y/220V,400Y/230Vor415Y/240V(3ø,4-wire+ground)
No internal batteries; external battery cabinet required.
SU100KX2 100kVA/80kW 380Y/220V,400Y/230Vor415Y/240V(3ø,4-wire+ground)
No internal batteries; external battery cabinet required.
SU120KX2 120kVA/96kW 380Y/220V,400Y/230Vor415Y/240V(3ø,4-wire+ground)
No internal batteries; external battery cabinet required.
SU20KSPM 20kVA/16kW 380Y/220V,400Y/230Vor415Y/240V(3ø,4-wire+ground)
Independent power module; chassis and external battery cabinet required.
SU120KXNP ChassisforindividualSU20KSPMpowermodules.Holdsupto6for120kVAcapacity.
EXTERNAL BATTERY CABINETS (Hardwire connection. Multiple cabinets can be parallel connected for extended runtime.)
BP480V55+/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries. (Seewww.tripplite.comforruntimeandloadsupportdata.)
BP480V78+/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries. (Seewww.tripplite.comforruntimeandloadsupportdata.)
BP480V103+/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries. (Seewww.tripplite.comforruntimeandloadsupportdata.)
BP480V140+/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries. (Seewww.tripplite.comforruntimeandloadsupportdata.)
WALL-MOUNTED EXTERNAL MAINTENANCE BYPASS PANELS WITH KEYED SAFETY INTERLOCK SYSTEM
SU80KMBPKX MaintenancebypasspanelforSU80KX2only.Kirk-keyedsafetyinterlocksystempreventssequence
of operation errors.
SU120KMBPKX MaintenancebypasspanelforSU100KX2andSU120KX2.Kirk-keyedsafetyinterlocksystemprevents
sequence of operation errors.
WALL-MOUNTED PARALLEL DISTRIBUTION PANELS (Required for parallel connection of UPS systems.)
SUPCXMBP80KX ParalleldistributionpanelforparallelconnectionofSU80KXorSU80KX2models.(Xcanbe2,3or4)
SUPCXMBP120KX ParalleldistributionpanelforparallelconnectionofSU100KX2orSU120KX2models.(Xcanbe2,3or4)
POWER MANAGEMENT ACCESSORIES
SNMPWEBCARD AddsEthernetnetworkinterfacetoUPSsystemforremotemonitoringandcontrolviaSNMP,Webortelnet.
MODBUSCARD AddsModbusinterfacetoUPSsystemsforremotemonitoringandcontrolviaModbusprotocol.
RELAYIOCARD AddscontactclosureinterfacetoUPSsystemsandallowscommunicationofstatusviasixconfigurable
contact closure outputs.
ENVIROSENSE Monitors temperature and humidity. Monitors up to three additional sensors via contact closure interface.
Requires SNMPWEBCARD.
WARRANTIES AND SERVICES
Sitesurveyservices,start-upservices,preventivemaintenanceservices,extendedwarrantiesandon-sitewarrantiesareavailable.
Visitwww.tripplite.comorcontactyourTrippLitesalesrepresentativeformoreinformation.
6
INP
UT
MODEL SU80KX2 SU100KX2 SU120KX2
NOMINAL VOLTAGE User-selectable380Y/220V,400Y/230Vor415Y/240V(3ø,4-wire+ground)
VOLTAGE RANGE Fullload:300Y/173Vto477Y/276V(-25%/+20%@400Y/230V)
≤70%Load:208Y/120Vto477Y/276V(-48%/+20%@400Y/230V)
CURRENT THDi (Full Load) <4%
POWER FACTOR (On-line, Full Load) >0,99
FREQUENCY (Auto-Selectable) 50/60Hz
FREQUENCY TOLERANCE ±5%
NOMINAL CURRENT
(@ 380/400/415 VAC, Per Phase)
103/99/95A (121/115/111Amaxwithcharger)
129/123/116A (152/144/139Amaxwithcharger)
155/148/142A (182/173/167Amaxwithcharger)
OU
TPU
T
CAPACITY (kVA/kW) 80/64 100/80 120/96
POWER FACTOR 0,8PerPhase
NOMINAL VOLTAGE User-selectable380Y/220V,400Y/230Vor415Y/240V(3ø,4-wire+ground)
FREQUENCY 50/60Hz±0,05Hz
NOMINAL CURRENT
(@ 380/400/415 VAC, Per Phase) 121/115/111A 152/144/139A 182/173/167A
WAVEFORM (On-line or Battery) Pure Sine Wave
VOLTAGE THD (Linear Load) <3%
VOLTAGE REGULATION (Static) ±1%
VOLTAGE REGULATION (Dynamic) Maximum7%Deviation
OVERLOAD CAPACITY ≤125%for10minutes;≤150%for60seconds
BR
EA
KE
RS
RECTIFIER (3-Pole, 600 VAC)**
150A 200A 225ABYPASS (3-Pole, 600 VAC)**
RESERVE (3-Pole, 600 VAC) **
OUTPUT (3-Pole, 600 VAC)**
BATTERY BATTERY (± 240VDC, Max
Current Draw at Full Load)** 165A 206A 247A
RECOMMENDED MINIMUM OCPD RATING** 150A 200A 225A
GE
NE
RA
L
STANDARD INTERFACE LED/LCDControlPanel,RS-232,ContactClosure,EPO(LocalandRemote)
OPTIONAL INTERFACE SNMPWEBCARD,ENVIROSENSE,RELAYIOCARD,MODBUSCARD
UPS TOPOLOGY TrueOn-line,DoubleConversion;Voltage/FrequencyIndependent(VFI-SS-111) Operation; Complies with EU Directives (EN62040-3)
AGENCY APPROVALS CE(CompliantwithEN62040-1-2,EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5, IEC61000-4-6),RoHS
EFFICIENCY (AC-AC) NormalMode:Upto94%/EconomyMode:Upto97%
TRANSFER TIME (Normal Mode) 0ms
AMBIENT OPERATING TEMPERATURE 0°Cto40°C(32°Fto104°F)
ELEVATION 0to3000m(0to10000ft)
HUMIDITY (Non-Condensing) ≤90%
AUDIBLE NOISE (@ 1 m) <70dBA
TYPICAL RUNTIME* (Half/Full Load) 28/10+min. (WithBP480V55)
20/7.6+min (WithBP480V55)
15/5.9+min (WithBP480V55)
DIMENSIONS (Power Module)
Height 1697mm(66,8in)
Width 521mm(20,5in)
Depth 975mm(38,4in)
UNIT WEIGHT (Power Module) 319kg (703lb)
347,5kg (766lb)
379,2kg (836lb)
SHIPPING WEIGHT (Power Module) 411,5kg (907lb)
441,5kg (973lb)
473,2kg (1043lb)
*Runtime varies with load, battery condition and other factors. Runtime can be extended by connecting additional external battery cabinets, sold separately. ** Breakers sized to configured load. If adding modules, size accordingly.
TECHNICAL SPECIFICATIONS
7
Tripp Lite’s 3-Phase PDUs offer reliable power distribution and monitoring in
high-voltage, high-density applications requiring 3-phase power service and are
compatible with all 3-phase UPS systems.
• METERED PDUs support real-time local-monitoring of load level.
• MONITORED PDUs support real-time remote monitoring of load level,
voltage and frequency with options for environmental and
security monitoring.
• SWITCHED PDUs support remote individual outlet control, monitoring
of output load level per outlet or per load bank, input voltage and frequency
reporting with options for environmental and security monitoring.
TRIPP LITE 3-PHASE POWER DISTRIBUTION UNITS
ABOUT TRIPP LITESince1922,TrippLitehasestablishedaglobalreputationfor
qualitymanufacturing,superiorvalueandexcellentservice.
TrippLitemakesmorethan2500productstopower,protect
andconnectelectronicequipment,includingUPSsystems,
replacementbatteries,powerdistributionunits,racksystems,
surgesuppressors,KVMswitches,cables,laptopaccessories,
power strips and inverters. Learn more at www.tripplite.com.
Copyright © 2013 Tripp Lite. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from actual products. 13-06-040 95-33CE
TRIPP LITE WORLD HEADQUARTERS 1111W.35thStreet,Chicago,IL60609USA,+1.773.869.1212,www.tripplite.com
TRIPP LITE MIDDLE EAST +971.4.887.1633•[email protected]•TRIPP LITE ASIA PACIFIC+972.54.2057646•[email protected]
TRIPP LITE EASTERN EUROPE+36.1.203.7941•[email protected]•TRIPP LITE EAST/WEST AFRICA+254.731.137.202•[email protected]
TRIPP LITE SOUTH AFRICA+27.82.8099.043•[email protected]•TRIPP LITE WESTERN EUROPE+33.1.70.61.77.85•[email protected]
TRIPP LITE UNITED KINGDOM +44.01635.887396•[email protected]
COMPLETE DATA CENTER SOLUTIONSProtect, manage and power your application with complete solutions from a single, trusted source.
UPS Systems
• Network-grade power protection for large data centers
• On-line,double-conversionoperation with pure sine wave output
• N+1powermoduleredundancy, parallel capability and expandable runtime.
KVMs
• Consolidated,centralized device management with improved security and availability.
• Built-inLCD consoles, Cat5 cabling, IP remote access with multiuser support and other advanced features available.
• Ruggedmetalconstructionand simple installation.
Bypass Panels & Accessories
• Wall-mount manual bypass panels isolate UPS systems from connected loads for maintenance with no loss of network availability.
• IncludedKirk-Key interlock system enhances system reliability.
• Heavy-dutybusworkandthreebuilt-in circuit breakers.
• CompatiblewithTrippLite3-phase UPS systems.
3-PHASE PDU FEATURES BY GROUPING
MeteredPDUs MonitoredPDUs SwitchedPDUsDistributePowerto Multiple Devices (Multiple Outlets) • • •
LocallyViewPDULoad(Digital Load Meter) • • •
RemotelyViewPDULoadand Alarm Conditions (Network Interface/Software) • •
RemotelyControlIndividual Outlets (Network Interface/Software/Switchable Outlets) •