SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option...

74
SIMATIC OS Web Option (V7.1) _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ Preface 1 Additional documentation 2 Overview of PCS 7 OS Web Option 3 Configuration with PCS 7 OS Web option 4 Hardware and Software Requirements 5 Installation of the OS Web Server 6 Configuration of the OS Web server on an ES 7 Completing configuration on the OS Web server 8 Installations and Settings for the Web Client 9 Time 10 Getting status information 11 Appendix 12 SIMATIC Process Control System PCS 7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01

Transcript of SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option...

Page 1: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

SIMATIC OS Web Option (V7.1)

____________________________

____________________________________________________________________________________________________________________________________________

Preface 1

Additional documentation

2

Overview of PCS 7 OS Web Option

3

Configuration with PCS 7 OS Web option

4

Hardware and Software Requirements

5

Installation of the OS Web Server

6

Configuration of the OS Web server on an ES

7

Completing configuration on the OS Web server

8

Installations and Settings for the Web Client

9

Time

10

Getting status information

11

Appendix

12

SIMATIC

Process Control System PCS 7OS Web Option (V7.1)

Function Manual

03/2009 A5E02122475-01

Page 2: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Legal information Legal information Warning notice system

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING indicates that death or severe personal injury may result if proper precautions are not taken.

CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.

CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.

NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account.

If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards.

Proper use of Siemens products Note the following:

WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed.

Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY

A5E02122475-01 Ⓟ 10/2008

Copyright © Siemens AG 2009. Technical data subject to change

Page 3: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 3

Table of contents

1 Preface ...................................................................................................................................................... 5 2 Additional documentation .......................................................................................................................... 9 3 Overview of PCS 7 OS Web Option......................................................................................................... 11

3.1 Using the PCS 7 OS Web Option ................................................................................................11 3.2 OS Web Server and Web Client ..................................................................................................14 3.3 Overview of Configuration Tasks.................................................................................................15 3.4 Information about the PCS 7 Web Option ...................................................................................16

4 Configuration with PCS 7 OS Web option................................................................................................ 17 4.1 Configuration Options ..................................................................................................................17 4.2 Configuration involving OS Web Server and Web Client ............................................................18 4.3 Configuration involving OS Web Standard Server and Web Client.............................................20 4.4 Configuration involving OS Web Diagnostics Server and Web Diagnostics Client .....................22

5 Hardware and Software Requirements .................................................................................................... 25 5.1 Requirements for the OS Web Server .........................................................................................25 5.2 Requirements for the Web Client.................................................................................................26

6 Installation of the OS Web Server............................................................................................................ 27 6.1 How to Install the OS Web Server ...............................................................................................27

7 Configuration of the OS Web server on an ES......................................................................................... 29 7.1 Overview of Configuration Tasks.................................................................................................29 7.2 Changes to project data...............................................................................................................30 7.2.1 Overview of Changes Performed by the Web View Publisher ....................................................30 7.2.2 Web-Executable Functions for PCS 7 OS Web Option...............................................................30 7.2.3 Requirements for Publishing........................................................................................................31 7.2.4 Overview of the Publishing Procedure.........................................................................................32 7.2.5 How to publish data .....................................................................................................................32 7.3 Setting the user rights, start screen and language ......................................................................35 7.3.1 Limitation of Access via User Permissions ..................................................................................35 7.3.2 How to Set User Permissions, Start Screen and Language in the User Administrator ...............35 7.4 Deactivating graphics runtime......................................................................................................37 7.4.1 How to Deactivate Graphics Runtime..........................................................................................37 7.5 Downloading the OS Web Server................................................................................................38 7.5.1 Downloading the OS Web Server................................................................................................38

Page 4: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Table of contents

OS Web Option (V7.1) 4 Function Manual, 03/2009, A5E02122475-01

8 Completing configuration on the OS Web server ..................................................................................... 39 8.1 Overview of Configuration Tasks ................................................................................................ 39 8.2 Checking the settings for the OS Web server............................................................................. 40 8.2.1 How to Check the Settings after Downloading............................................................................ 40 8.3 Configuration of the Web page ................................................................................................... 41 8.3.1 Using the Web Configurator........................................................................................................ 41 8.3.2 Calling up the OS Web Navigator start screen ........................................................................... 41 8.3.3 Setting options for calling up the default web page .................................................................... 42 8.3.4 How to set the default web page for the Web Clients................................................................. 44

9 Installations and Settings for the Web Client............................................................................................ 47 9.1 Preparations................................................................................................................................ 47 9.2 Overview of the Installation Procedure ....................................................................................... 48 9.3 Internet Explorer settings ............................................................................................................ 49 9.3.1 Setting the Web content zone..................................................................................................... 49 9.3.2 How to set the "Internet" or "Local Intranet" Web content zones................................................ 49 9.3.3 How to set the "Trusted Sites" web content zone....................................................................... 50 9.4 How to Install the Web Client on Your PC .................................................................................. 51 9.5 How to Install Plug-ins................................................................................................................. 53 9.6 How to Start Process Control on the Web Client ........................................................................ 55 9.7 How to Set the Language for the Navigation Bar on the Web Client.......................................... 56 9.8 Removal and retro-installation/Update incl. plug-ins on the Web client ..................................... 56 9.8.1 Removal and Retro-installation/Update of Plug-ins on the Web Client ...................................... 56 9.9 Web Client functions in process mode........................................................................................ 57 9.9.1 Web Client user interface............................................................................................................ 57 9.9.2 Functionality on the Web Client .................................................................................................. 58

10 Time ........................................................................................................................................................ 61 10.1 Time-of-day displays on the Web Client ..................................................................................... 61 10.2 Web Client time-of-day synchronization ..................................................................................... 62

11 Getting status information........................................................................................................................ 63 11.1 Status Information about OS Web Server and Web Clients ....................................................... 63 11.2 How to Display Status Information.............................................................................................. 64

12 Appendix.................................................................................................................................................. 65 12.1 Supported Functions "BPC" and "APC"...................................................................................... 65

Index........................................................................................................................................................ 71

Page 5: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 5

Preface 1Purpose of the documentation

This documentation provides information about the PCS 7 OS Web Option software components, application areas, configuration options and commissioning process for SIMATIC PCS 7. It answers the following key questions: ● What is PCS 7 OS Web Option? ● What are the software components associated with PCS 7 OS Web Option? ● What hardware and software requirements apply and which licenses are required for

installation? ● Which application areas are covered by PCS 7 OS Web Option? ● What is the procedure for using PCS 7 OS Web Option? ● What is the procedure for commissioning PCS 7 OS Web Option? This documentation is available in electronic format on the SIMATIC PCS 7; Manual Collection DVD. You can use Adobe Reader to read the documentation and print it out as necessary. Accessing documentation on the PCS 7 PC: ● You can open the electronic copy of the manual (PDF) by selecting

Start > SIMATIC > Documentation > <Language*> > PCS 7 OS Web Option. * Replace <Language> with your regional language.

● The manual can be accessed via the Online Help (CHM) if you select Start > SIMATIC > Documentation > Language* > PCS 7 - Basic documentation > OS Web Option. Alternatively, you can access it directly from the SIMATIC Manager by selecting Help > Contents > OS Web Option. * Replace <Language> with your regional language.

Basic knowledge required This documentation is aimed at anyone who is involved in configuring, commissioning and operating automated systems based on SIMATIC PCS 7. A certain amount of basic knowledge is assumed and readers are expected to know how to use a PC/PG and the Windows operating system in general. They should already be familiar with the SIMATIC PCS 7 functions and configurations.

Scope of the documentation This documentation covers the Process Control System; PCS 7 Toolset software package, V7.1 or later.

Page 6: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Preface

OS Web Option (V7.1) 6 Function Manual, 03/2009, A5E02122475-01

Readme file You can glean the latest high-priority information from the readme file: ● The readme file is located on the Process Control System; PCS 7 Toolset DVD. ● You can open the readme file after installing PCS 7 by selecting the Start > SIMATIC >

Product Notes > <language*> > PCS 7 - Readme menu command. * Select your regional <language>.

Conventions Within this documentation, the software interface terminology has been localized in accordance with the documentation language. However, if you have installed a multilanguage operating system package, certain terms may be displayed in the basic language of the operating system if you decide to switch languages and these will deviate from the terminology used in the documentation.

PCS 7 glossary A PCS 7 glossary which defines the key technical terms used in the documentation is available on the SIMATIC PCS 7; Manual Collection DVD or via the SIMATIC Manager help menu in the PCS 7 software (menu command Help > Contents > "Glossary" button).

Page 7: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Preface

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 7

Further Support If you have any technical questions, please get in touch with your Siemens representative or responsible agent. You will find your contact person at: http://www.siemens.com/automation/partner You will find a guide to the technical documentation offered for the individual SIMATIC Products and Systems at: http://www.siemens.com/simatic-tech-doku-portal The online catalog and order system is found under: http://mall.automation.siemens.com/

Training Centers Siemens offers a number of training courses to familiarize you with the Process Control System SIMATIC PCS 7. Please contact your regional training center or our central training center in D 90327 Nuremberg, Germany for details: Telephone: +49 (911) 895-3200 *) Internet: http://www.sitrain.com

Page 8: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Preface

OS Web Option (V7.1) 8 Function Manual, 03/2009, A5E02122475-01

Technical Support You can reach the Technical Support for all Industry Automation and Drive Technology products ● Via the Web formula for the Support Request

http://www.siemens.com/automation/support-request ● Phone: + 49 180 5050 222 *) ● Fax: + 49 180 5050 223 *) Additional information about our Technical Support can be found on the Internet pages http://www.siemens.com/automation/service

Service & Support on the Internet In addition to our documentation, we offer our Know-how online on the internet at: http://www.siemens.com/automation/service&support where you will find the following: ● The newsletter, which constantly provides you with up-to-date information on your

products. ● The right documents via our Search function in Service & Support. ● A forum, where users and experts from all over the world exchange their experiences. ● Your local representative for Industry Automation and Drive Technology. ● Information on field service, repairs, spare parts and consulting.

*) Please note the following if you call the phone number listed: You may incur costs which vary from the standard costs for land lines. Calls from a cellular network may be more expensive.

Page 9: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 9

Additional documentation 2Additional documentation

The following table lists documentation in which you will find additional information. The entire content of the online help (CHM) is also available in the electronic manuals (PDF). Online Help/Manual Purpose After installation of SIMATIC

PCS 7 it can be opened via: Manual: SIMATIC Logon, SIMATIC Electronic Signature

Provides support for setting up central administration of access rights using SIMATIC Logon

Manual: Start > SIMATIC > Documentation > <Language*> > SIMATIC Logon

Online Help: Web Navigator Information System Manual: SIMATIC HMI WinCC/Web Navigator

As WinCC Product Information, this manual contains all the information you will need to install and configure the WinCC Web Navigator Server and Client.

Online Help: Start > SIMATIC > WinCC > Web Navigator > Web Navigator Information System Manual: When you have opened the online help, select "Web Navigator Information System" from the menu bar under Options > PDF. Note You can only call up the online help and manual from an OS Web Server.

Manual: Process Control System PCS 7 Programming Instructions for Blocks

The Programming Instructions describe how to create PCS 7-compliant AS blocks or faceplates.

Manual: Can only be called up from an engineering station (ES) via Start > SIMATIC > Documentation > <Language*> > PCS 7 - Programming Instructions for Blocks

Online Help: Configuration - Operator Station Manual: Process Control System PCS 7 Operator Station

Helps you to configure the SIMATIC PCS 7 process control system on an operator station.

Online Help: Start > SIMATIC > Documentation > <Language*> > PCS 7 basic documentation > Configuration - Operator Station Manual: Start > SIMATIC > Documentation > <Language*> > PCS 7 Operator Station Configuration Manual

Page 10: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Additional documentation

OS Web Option (V7.1) 10 Function Manual, 03/2009, A5E02122475-01

Online Help/Manual Purpose After installation of SIMATIC PCS 7 it can be opened via:

Online Help: Configuration - Engineering System Manual: Process Control System PCS 7 Engineering System

Helps you to configure the SIMATIC PCS 7 process control system on an engineering system.

Online Help: Start > SIMATIC > Documentation > <Language*> > PCS 7 basic documentation > Configuration - Engineering System Manual: Start > SIMATIC > Documentation > <Language*> > PCS 7 Engineering System Configuration Manual

Online Help: Operator Station Process Management Manual: Process Control System PCS 7 OS Process Control

Provides detailed instructions for operator control and monitoring of processes using the SIMATIC PCS 7 process control system, including all necessary information for safe operation.

Online Help: Start > SIMATIC > Documentation > <Language*> > PCS 7 - Basic Documentation > OS Process Management Manual: Start > SIMATIC > Documentation > <Language*> > PCS 7 OS Process Management

* Replace <Language> with your regional language.

Page 11: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 11

Overview of PCS 7 OS Web Option 33.1 Using the PCS 7 OS Web Option

Introduction PCS 7 OS Web Option enables operator control and monitoring of automated processes over the Intranet/Internet using PCS 7. You can use PCS 7 OS Web Option on a PCS 7 system: ● With a PCS 7 OS multiple station system ● With a PCS 7 OS single station system PCS 7 OS Web Option consists of two components: ● PCS 7 OS Web Server ● PCS 7 Web Client

Using the product on a PCS 7 OS multiple station system On a PCS 7 OS multiple station system, PCS 7 OS Web Server acts as an OS Client with PCS 7 OS Web Server functionality. Once an OS Client has been configured as a PCS 7 OS Web Server, it can no longer be used as an operating station (OS Client, SIMATIC BATCH Client or Route Control Client) within the PCS 7 system. A PCS 7 Web Client uses Internet Explorer to access the project data on the PCS 7 OS Web Server over the Intranet/Internet. Operator control and monitoring of the process is supported.

Page 12: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Overview of PCS 7 OS Web Option 3.1 Using the PCS 7 OS Web Option

OS Web Option (V7.1) 12 Function Manual, 03/2009, A5E02122475-01

Example configuration The following figure shows the PCS 7 system configuration when PCS 7 OS Web Option is used on an OS multiple station system.

Page 13: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Overview of PCS 7 OS Web Option 3.1 Using the PCS 7 OS Web Option

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 13

Using the product on a PCS 7 OS single station system When used on a PCS 7 OS single station system, the PCS 7 OS Web Server provides PCS 7 OS Web Server functionality. Once the PCS 7 OS single station system has been configured as a PCS 7 OS Web Server, it can continue to function as a PCS 7 OS on the PCS 7 system. The PCS 7 OS single station system can be operated on two different bases: ● PCS 7 OS single station system (OS single station) ● PCS 7 OS single station system (engineering station and OS on one PC station) If the PCS 7 OS single station system takes the form of the PCS 7 OS single station system (engineering station and OS on one PC station), then process control and engineering cannot be performed simultaneously. A PCS 7 Web Client uses Internet Explorer to access the project data on the PCS 7 OS Web Server over the Intranet/Internet. Operator control and monitoring of the process is supported. Depending on the requirements of your PCS 7 system, you have a choice of two configurations: ● PCS 7 OS Web Standard Server and PCS 7 Web Client ● PCS 7 OS Web Diagnostics Server and PCS 7 Web Diagnostics Client

Note for the reader Throughout the remainder of the documentation, the term OS single station system shall be used to refer to both implementations: "OS single station" and "engineering station and OS on one PC station". The reader's attention will be drawn to any differences between the two, where applicable.

Terminology The following terms appear in the documentation:

Term Synonym used in the documentation Scope PCS 7 OS Web Server OS Web Server Information applies to all configurations PCS 7 Web Client Web Client Information applies to all configurations PCS 7 OS Web Standard Server OS Web Standard Server Information only applies to OS single station

systems (with standard license key) PCS 7 OS Web Diagnostics Server PCS 7 Web Diagnostics Client

OS Web Diagnostics Server Web Diagnostics Client

Information only applies to OS single station systems (with diagnostics license key)

Page 14: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Overview of PCS 7 OS Web Option 3.2 OS Web Server and Web Client

OS Web Option (V7.1) 14 Function Manual, 03/2009, A5E02122475-01

3.2 OS Web Server and Web Client

OS Web Server All the screens and required scripts are stored on the OS Web server so that they can be displayed or run on the Web client. All screens and scripts must be prepared accordingly (published). The Web View Publisher is used for this purpose.

Note The following applies in an OS multi-user system: The data from various OS servers can be prepared (published) on the OS Web server. The OS Web Server may not be used as an operator station (OS Client, BATCH Client or Route Control Client) as it cannot guarantee the required reaction and response times.

Web Client The operator can log on at the Web client and access the data on the OS Web server by means of a TCP/IP connection. The user interface displayed in Internet Explorer corresponds with the appearance of the user interface on the operator station (OS) with an overview area, work area, and key area. All operations that the operator performs on the OS Web client are automatically logged with the name of the operator.

Note The Web client must not be used as an additional PCS 7 station.

Page 15: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Overview of PCS 7 OS Web Option 3.3 Overview of Configuration Tasks

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 15

3.3 Overview of Configuration Tasks

Overview of configuration steps required The following table provides you with an overview of the PCS 7 OS Web Option configuration steps and show the recommended order for carrying them out. Step Where? What? 1 Engineering

station (ES) Publish pictures in Web View Publisher (Page 30)

2 Engineering station (ES)

Configure the user rights, start screen and language in the User Administrator for the purpose of accessing Web Clients (Page 35)

3 Engineering station (ES)

In the case of an OS multi-user system: Deactivate the graphics runtime option in the "Computer properties" dialog box (Page 37)

4 OS Web Server Install OS Web Server (Page 27) 5 Engineering

station (ES) Download project onto OS Web Server (Page 38)

6 OS Web Server Check settings in the User Administrator once the project has been downloaded onto the OS Web Server (Page 40)

7 OS Web Server In the case of an OS multiple station system: Check that graphics process mode has been deactivated in the "Computer properties" dialog box. (Page 37)

8 OS Web Server Execute the Web Configurator (Page 41) 9 Web Client Installation and setting operations for the Web Client (Page 48)

Page 16: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Overview of PCS 7 OS Web Option 3.4 Information about the PCS 7 Web Option

OS Web Option (V7.1) 16 Function Manual, 03/2009, A5E02122475-01

3.4 Information about the PCS 7 Web Option

Web Client setup If you decide to install the Web Client by downloading it from the Intranet/Internet you can choose whether to "Open" or "Save" the setup file. You should make a note of which option you select when installing the Web Client for the first time, because you will need to use the same method when installing subsequent plug-ins. If the methods do not match, you will get an error message. However, you will not get an error message if you combine the "From DVD" and "Download and save" installation methods.

The performance of your OS Web Server ● The speed and bandwidth of your OS Web Server Internet connection will have a

significant impact on performance in terms of your PCS 7 projects, your Web Client's update times as well as when opening pictures. Each Web Client requires a bandwidth of approx. 10 kbps.

● Maximum performance can be achieved on a LAN (rather than with a 64 kbps/ISDN modem) and this will prove beneficial in terms of picture downloading times, the update process and the number of Web Clients that can be operated simultaneously.

● Synchronous script functions place a great deal of strain on the system. For this reason, you should not use the "SetTagxxx" function in cyclic scripts. If a large number of Web Clients (>10) call SetTagxxx functions in a rapid cycle (1s or less), the OS Web Server will become overloaded.

Fail-safe components Access to the HMI system for fail-safe components ("F-HMI" components from the "F-Systems" add-on package) is not approved.

Additional information For additional information, refer to the Online Help for the WinCC Information System.

Page 17: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 17

Configuration with PCS 7 OS Web option 44.1 Configuration Options

Overview of configurations The following configurations are possible when you use PCS 7 OS Web Option on a PCS 7 system: ● With a PCS 7 OS multiple station system

– Configuration involving OS Web Server and Web Client (Page 18) ● With a PCS 7 OS single station system

– Configuration involving OS Web Standard Server and Web Client (Page 20) – Configuration involving OS Web Diagnostics Server and Web Diagnostics Client

(Page 22)

NOTICE

Note the following: • OS Web Option is not released for OS single station systems with SIMATIC

BATCH. • The ideal (standard) solution is a configuration involving an OS Web Standard

Server and Web Client. The configuration involving OS Web Diagnostics Servers and Web Diagnostics Clients is only intended for systems that feature a relatively small number of clients and where the clients only connect to the servers intermittently for diagnostic purposes.

Page 18: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration with PCS 7 OS Web option 4.2 Configuration involving OS Web Server and Web Client

OS Web Option (V7.1) 18 Function Manual, 03/2009, A5E02122475-01

4.2 Configuration involving OS Web Server and Web Client

Introduction You use this configuration in the case of an OS multiple station system.

Example configuration The following figure shows an example PCS 7 system configuration for the configuration that involves an OS Web Server and Web Client on an OS multiple station system.

Page 19: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration with PCS 7 OS Web option 4.2 Configuration involving OS Web Server and Web Client

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 19

Installation and license key requirements With an OS multiple station system, you will need to carry out the following installation operations: ● Install the "OS Web Server" software package from the PCS 7 Toolset DVD as part of the

general setup routine on the OS Web Server (OS Client) ● Install the "Web Client" software package

There are two options for installing the software package: – Remote installation – Local installation For additional information about installing the software package refer to the section "How to install the Web Client on your PC (Page 51)".

● Install plug-ins For additional information about installing the plug-ins refer to the section "How to install the plug-ins (Page 53)".

● Install a license key for the OS Web Server and Web Clients on the OS Web Server (OS Client) For additional information about the necessary license keys, please refer to the manual titled PCS 7 Process Control System; PC Configuration and Authorization.

Number of Web Clients In the case of an OS multiple station system, the maximum number of Web Clients supported by an individual OS Web Server is 3, 10, 25, or 50. The maximum number of Web clients is limited by the license key.

Page 20: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration with PCS 7 OS Web option 4.3 Configuration involving OS Web Standard Server and Web Client

OS Web Option (V7.1) 20 Function Manual, 03/2009, A5E02122475-01

4.3 Configuration involving OS Web Standard Server and Web Client

Introduction You use this configuration in the case of an OS single station system.

Example configuration The following figure shows an example PCS 7 system configuration for the configuration that involves an OS Web Standard Server and Web Client on an OS single station system.

Page 21: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration with PCS 7 OS Web option 4.3 Configuration involving OS Web Standard Server and Web Client

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 21

Installation and license key requirements With an OS single station system, you will need to carry out the following installation operations: ● Install the "OS Web Server" software package from the PCS 7 Toolset DVD as part of the

general setup routine on the OS Web Standard Server (OS single station system) ● Install the "Web Client" software package

There are two options for installing the software package: – Remote installation – Local installation For additional information about installing the software package refer to the section "How to install the Web Client on your PC (Page 51)".

● Install plug-ins For additional information about installing the plug-ins refer to the section "How to install the plug-ins (Page 53)".

● Install a license key for the PCS 7 OS Web Standard Server and Web Clients on the OS Web Standard Server (OS single station system) For additional information about the necessary license keys, please refer to the manual titled PCS 7 Process Control System; PC Configuration and Authorization.

Number of Web Clients In the case of an OS single station system, the maximum number of Web Clients simultaneously supported by an individual Web Standard Server is 3.

Page 22: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration with PCS 7 OS Web option 4.4 Configuration involving OS Web Diagnostics Server and Web Diagnostics Client

OS Web Option (V7.1) 22 Function Manual, 03/2009, A5E02122475-01

4.4 Configuration involving OS Web Diagnostics Server and Web Diagnostics Client

Introduction You use this configuration in the case of an OS single station system. This configuration is the key to cost-effective teleservice when just one or only a small number of Web Diagnostics Clients are operated in conjunction with several OS single station systems/OS Web Diagnostics Servers.

NOTICE The ideal (standard) solution is a configuration involving an OS Web Standard Server and Web Client. The configuration involving OS Web Diagnostics Servers and Web Diagnostics Clients is only intended for systems that feature a relatively small number of clients and where the clients only connect to the servers intermittently for diagnostic purposes.

Page 23: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration with PCS 7 OS Web option 4.4 Configuration involving OS Web Diagnostics Server and Web Diagnostics Client

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 23

Example configuration The following figure shows an example PCS 7 system configuration for the configuration that involves an OS Web Diagnostics Server and Web Diagnostics Client on an OS single station system.

Page 24: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration with PCS 7 OS Web option 4.4 Configuration involving OS Web Diagnostics Server and Web Diagnostics Client

OS Web Option (V7.1) 24 Function Manual, 03/2009, A5E02122475-01

Installation and license key requirements With an OS single station system, you will need to carry out the following installation operations: ● Install the "OS Web Server" software package from the PCS 7 Toolset DVD as part of the

general setup routine on the OS Web Diagnostics Server (OS single station system) ● Install the "Diagnostic Client" software package

– Local installation For additional information about installing the software package refer to the section "How to install the Web Client on your PC (Page 51)".

● Install plug-ins For additional information about installing the plug-ins refer to the section "How to install the plug-ins (Page 53)".

● How to install the license key – Install a license key for each OS Diagnostics Server on the OS Web Diagnostics

Server (OS single station system) – Install a license key for each Web Diagnostics Client on the Web Diagnostics Client For additional information about the necessary license keys, please refer to the manual titled PCS 7 Process Control System; PC Configuration and Authorization.

Number of Web Clients ● The maximum number of Web Diagnostics Clients simultaneously supported by one

OS Web Diagnostics Server is 3. ● Each Web Diagnostics Client can access up to 3 OS Web Diagnostics Servers

simultaneously.

Page 25: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 25

Hardware and Software Requirements 55.1 Requirements for the OS Web Server

Hardware and software requirements The OS Web Server must meet the following hardware and software requirements: Feature Requirement Operating system Windows Server 2003 Software • Internet Explorer

• Internet Information Services (IIS)

Minimum hardware (PC) Intel Pentium IV, 2.8 GHz, 1 GB work memory Recommended hardware (PC) Intel Pentium IV, 3,4 GHz, 1 GB work memory Miscellaneous Fast access (>= 64 kbit/s) to Web Client over Intranet/Internet or

via TCP/IP connection

Additional information For additional information about the hardware and software requirements refer to the document Process Control System PCS 7; PCS 7 Readme. The PCS 7 Readme is opened by using the menu item Start > SIMATIC > Product Info > <Language*> > PCS 7 Readme.

Page 26: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Hardware and Software Requirements 5.2 Requirements for the Web Client

OS Web Option (V7.1) 26 Function Manual, 03/2009, A5E02122475-01

5.2 Requirements for the Web Client

Hardware and software requirements The Web Client must meet the following hardware and software requirements: Feature Requirement Possible operating systems • Windows Server 2003

• Windows XP Professional

Software Internet Explorer Minimum hardware (PC) No PDAs, tablet PCs, etc. Miscellaneous Fast access (>= 64 kbit/s) to OS Web Server over

Intranet/Internet or via TCP/IP connection

Additional information For additional information about the hardware and software requirements refer to the document Process Control System PCS 7; PCS 7 Readme. The PCS 7 Readme is opened by using the menu item Start > SIMATIC > Product Info > <Language*> > PCS 7 Readme.

Page 27: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 27

Installation of the OS Web Server 66.1 How to Install the OS Web Server

Requirements The following requirements apply when installing the OS Web Server: ● For an OS multiple station system

– Windows Server 2003 must be installed on the OS Client. – The OS Client must only be used as an OS Web Server. – The requirements specified in the "Requirements for the OS Web Server (Page 25)"

section must be met. ● For an OS single station system

– Windows Server 2003 must be installed on the OS single station system. – The requirements specified in the "Requirements for the OS Web Server (Page 25)"

section must be met.

Software package The "OS Web Server" program package, which is included as part of the PCS 7 general setup routine on the PCS 7 Toolset DVD, applies to all configurations: ● Configuration involving Web Server and Web Client (OS multiple station system)

(Page 18) ● Configuration involving OS Web Standard Server and Web Client (OS single station

system) (Page 20) ● Configuration involving OS Web Diagnostics Server and Web Diagnostics Client (OS

single station system) (Page 22)

Page 28: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installation of the OS Web Server 6.1 How to Install the OS Web Server

OS Web Option (V7.1) 28 Function Manual, 03/2009, A5E02122475-01

Procedure 1. Insert the PCS 7 Toolset DVD into the DVD drive. 2. Double-click "Setup.exe" to start the setup.

Setup starts. 3. Follow the setup instructions until you reach the "Type of installation" dialog box. 4. Select the "package installation" radio button. 5. Click "Next".

The "Program packages" dialog box opens. 6. To allow operator control and monitoring via the PCS 7 OS Web Server, check the

relevant check box shown in the table below, and follow the instructions until you reach the end of the setup process.

Program package selection as part of the general setup routine

OS multiple station system

OS single station system (OS single station)

OS single station system (engineering station and OS on one PC station)

Runtime > Web Server > Check "OS Web Server" box

X X X

Runtime > Single station > Check "OS single station" box

X

Engineering > Check "PCS 7 engineering" box

X

Page 29: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 29

Configuration of the OS Web server on an ES 77.1 Overview of Configuration Tasks

Overview The following table provides an overview of the OS Web server configuration tasks on the engineering station in the OS Web server project. Step Where? What? 1 Engineering

station (ES) Publish pictures in Web View Publisher (Page 30)

2 Engineering station (ES)

Configure the user rights, start screen and language in the User Administrator for the purpose of accessing Web Clients (Page 35)

3 Engineering station (ES)

In the case of an OS multiple station system: Deactivate the graphics runtime option in the "Computer properties" dialog box (Page 37)

4 Engineering station (ES)

Download project onto OS Web Server (Page 38)

Project changes

Note Always make changes to the project on the ES.

Page 30: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.2 Changes to project data

OS Web Option (V7.1) 30 Function Manual, 03/2009, A5E02122475-01

7.2 Changes to project data

7.2.1 Overview of Changes Performed by the Web View Publisher

Tasks of the Web View Publisher The Web View Publisher makes all pictures and scripts displayed or executed on the Web client known on the OS Web server: it publishes them. The following actions are performed here: ● Project data are compressed and saved. ● Picture windows in process pictures are converted into internet-executable ActiveX

components. ● Scripts are converted so that they can run in the Web

7.2.2 Web-Executable Functions for PCS 7 OS Web Option

Supported script normal functions The PCS 7 OS Web Option does not support all script functions. Lists of web-executable normal script functions for the Web client are available in the following sections or documentation: ● In the following sections of this manual:

– "Supported Functions on Web Client (Page 58)" – ""BPC" and "APC" Supported Functions (Page 65)"

● In the Web Navigator Information System online help (can only be called up on an OS Web Server using the Start > SIMATIC > WinCC > Web Navigator > WebNavigator Information System menu command) in the following sections: – "Supported functions" – "Non-supported functions"

● In the PCS 7 – Programming Instructions for Blocks manual (can only be called up on an engineering station (ES) using the Start > SIMATIC > Documentation > <Language*> > PCS 7 Programming Instructions for Blocks menu command) in the "Function names in WinCC/Web" section. * Replace <Language> with your regional language.

Page 31: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.2 Changes to project data

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 31

7.2.3 Requirements for Publishing

Requirements In order to edit data on the ES with Web View Publisher, you must first ensure that the following data publishing requirements have been met: ● The PCS 7 project must have been created and fully configured. ● The "Compile OS" function must have been performed for all operator stations. ● The C and VB scripts for all the OS servers that are to be accessed by the Web Clients

must be available on the OS Web Server. ● The names of the process mimics to be used by the Web Clients must not contain any

double underscores (e.g., yy__xx.pdl). The character string that precedes the two underscores will be interpreted as a separator for the server prefix.

● The "@PTN_xx.pdl" pictures are OS Web Server-specific and must be published by each OS Web Server with the relevant server prefix.

● Plain text variable names (in quotation marks) in C scripts must not contain any spaces. ● In the case of an OS multiple station system, the following additional requirements apply:

– An OS Client must have been added to your PCS 7 project as a PC station to serve as an OS Web Server. For additional information about creating and configuring a PC station refer to the PCS 7 Process Control System; Engineering System manual.

– The server data for the OS Server that is to be accessed by the Web Client must have been downloaded onto the OS Web Server. For additional information about downloading server data refer to the section "How to download server data" in the Process Control System PCS 7; Operator Station manual.

Page 32: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.2 Changes to project data

OS Web Option (V7.1) 32 Function Manual, 03/2009, A5E02122475-01

7.2.4 Overview of the Publishing Procedure

Basic Procedure On the ES, 1+n publishing processes are necessary, whereby "n" is the number of servers (server pairs in case of redundancy) that the OS Web server accesses or whose pictures are to be published. The first publishing process edits local @-pictures and functions on the OS Web server. The further publishing processes edit the pictures of the OS servers.

Note In the case of an OS single station system only one publishing process is required to publish the local data on the OS Web server.

The following standard procedure applies to publishing: 1. Open the OS Web server project on the ES; set the source paths and destination path

during configuration on the ES. 2. Publish all the pictures of the WinCC source projects on the ES (1+n actions) and then

load them onto the PC station of the OS Web server.

7.2.5 How to publish data

Procedure 1. Open the SIMATIC Manager component view on the ES. 2. In the tree view, select the OS that is acting as the OS Web Server.

Select the Edit > Open object menu item. 3. Open the "Web Navigator" editor in WinCC Explorer. 4. Select the Web View Publisher command from the shortcut menu.

The "WinCC Web Publishing Wizard - Introduction" is opened. 5. Click "Next".

The "WinCC Web Publishing Wizard - Select files and folders" dialog box is opened. 6. To publish local data, proceed as follows:

– Clear the "Server prefix" check box. 7. To publish data from OS Servers, proceed as follows:

– Select the "Server prefix" check box. – From the drop-down list box, select the OS Server that is to be accessed by the Web

Client. The server prefix regulates the data access and corresponds to the logical OS Server name.

8. If you want to use the preset target and source path, proceed with Step 11.

Page 33: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.2 Changes to project data

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 33

9. If you want to change the preset source path, proceed as follows: – Click the "Browse" button next to the "Path to your WinCC project:" input field. – Select the desired path.

10. If you want to change the preset target path, proceed as follows: – Click the "Browse" button next to the "Folder for Web access to your pictures:" input

field. – Select the desired path.

Ensure that the same path is entered for the publishing of local data and the publishing of data from OS Servers. After all the paths have been specified, check the server prefix in the drop-down list box.

11. Click "Next". The "WinCC Web Publishing Wizard - Select pictures" dialog box is opened. You will be presented with all the standard and all the project-specific pictures.

12. Select the pictures that you wish to publish: – Click ">>" to publish all the pictures. – If you only want to publish a selection of the pictures, hold down the <Ctrl> key and

select the ones you want. Then click ">".

Note: We would recommend that you always publish all the standard pictures. 13. Click "Next".

The "WinCC Web Publishing Wizard - Select functions" dialog box is opened. You will be presented with the standard functions and the project functions (project-specific C scripts) that you have saved onto the OS Web Server.

14. Select the functions that you wish to publish: – Click ">>" to publish all the functions. – If you only want to publish a selection of the functions, hold down the <Ctrl> key and

select the ones you want.

Note: The pictures will only offer the scripts that were selected during the last publication process. You should, therefore, select all the functions that are required whenever you carry out a publication process.

15. Click "Next". The "WinCC Web Publishing Wizard - Referenced graphics" dialog box is opened. Here both the standard graphics as well as the project-specific graphics that are integrated in the process pictures are displayed.

16. Click ">>" to publish all the graphics. 17. Select the graphics that you want to publish:

– Click ">>" to publish all the graphics. – If you only want to publish a selection of the graphics, hold down the <Ctrl> key and

select the ones you want. Then click ">".

Note: We would recommend that you always publish all the graphics.

Page 34: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.2 Changes to project data

OS Web Option (V7.1) 34 Function Manual, 03/2009, A5E02122475-01

18. Then click "Next". The "WinCC Web Publishing Wizard - Exit" dialog box is opened.

19. Click "Finish". 20. At the end of the publication process click "OK" to confirm the message "Pictures

successfully transferred to OS Web Server". The pictures will now be listed in the "WinCC Web Publishing Wizard - Exit" dialog box. Pictures and functions that contain faulty scripts are marked with a red cross and displayed in a dialog box.

21. Double-click on each faulty picture to open and correct it in the "PdlPad" editor. Check any faulty scripts for unsupported functions.

22. In the "PdlPad" editor, select Edit > Check Scripts. The compilation window provides information about potential errors including the relevant row number. Note: Any changes that you make in the "PdlPad" editor will be discarded when you next carry out a publication process. Therefore, you should first correct the pictures in the Graphics Designer and then repeat the publication process.

23. Once you have corrected all the pictures, click "Finish". The extension for the published data is *.pd_.

Result The published pictures are displayed in the Web Navigator data window.

Page 35: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.3 Setting the user rights, start screen and language

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 35

7.3 Setting the user rights, start screen and language

7.3.1 Limitation of Access via User Permissions

Restricting access You can control the level of access that the Web Client has to the OS system by means of user rights. You can assign these user rights in the User Administrator editor of the OS Web Server. The user rights correspond to those of the standard clients. In addition to the user rights of the standard clients you can assign the "Web Access - only monitor" user right to the Web Client. Before you can assign user rights, you will first need to have prepared all the data using Web View Publisher.

7.3.2 How to Set User Permissions, Start Screen and Language in the User Administrator

Requirement The necessary data must have been published with Web View Publisher.

Procedure 1. On the ES, open the User Administrator editor of the OS Web Server. 2. Create the new users/operators or user groups and assign the required authorizations to

them. For additional information refer to the Process Control System PCS 7; Operator Station manual.

3. In the tree view, select the desired user group or individual user. 4. Check the "Web Navigator" box.

Two additional input fields will appear. 5. Click "Browse" next to the "Start screen" input field.

The "Open" dialog box will appear. The "Open" dialog box will present you with all the graphics that you have published.

6. Select the file called "@screen.pd_". Check that the image file can be traced to the path ..\OS Web Server\<wincc project release name>\Web Navigator\pictures and click "Open".

7. If you wish to set a specific language for the user groups or individual user concerned, click "Browse" next to the "Language" input field.

Page 36: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.3 Setting the user rights, start screen and language

OS Web Option (V7.1) 36 Function Manual, 03/2009, A5E02122475-01

8. In the "Select language" dialog box, select the desired language for the Web Client operator control and monitoring interface and then click "OK".

9. Close the User Administrator.

CAUTION

When selecting a language, please ensure that you have configured the relevant language for all process mimics. For example, in a label field you will need to have entered the label text in all the languages.

Page 37: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.4 Deactivating graphics runtime

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 37

7.4 Deactivating graphics runtime

7.4.1 How to Deactivate Graphics Runtime

Introduction With an OS multiple station system, once an OS client has been configured as a PCS 7 OS Web Server, it can no longer be used as an operating station (OS Client) within the PCS 7 system. You should, therefore, deselect "Graphics runtime" in the startup list, which will have been selected by default.

NOTICE In the case of an OS single station system, there is no need to deselect "Graphics runtime".

Procedure 1. Open the OS Web Server in WinCC Explorer on the ES.

Alternatively, in SIMATIC Manager (component view) select Project name > PC station name > WinCC application > OS Web Server name.

2. In the tree view, click the "PC" component. 3. Open the context menu for the name displayed in the data window and select Properties. 4. Go to the "Startup" tab and deselect "Graphics runtime" in the "Order when starting

WinCC runtime" group. 5. Click "OK" to apply the setting.

Result When WinCC starts in process mode on the OS Web Server, the graphics runtime interface will not be launched.

Page 38: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Configuration of the OS Web server on an ES 7.5 Downloading the OS Web Server

OS Web Option (V7.1) 38 Function Manual, 03/2009, A5E02122475-01

7.5 Downloading the OS Web Server

7.5.1 Downloading the OS Web Server

Downloading As the OS Web Server essentially consists of an operating station (OS), the procedure for downloading to the OS Web Server is the same as when downloading to an operating station (OS).

Note If the ES and OS are installed on the same PC station, and this station is also configured as an OS Web Server, there is no need to download the OS Web Server (such as OS single station system with ES/OS/OS Web Server).

Downloading changes

Note If the OS Web Server is configured in an OS single station system, a download of changes at the OS Web Server is possible.

Information relating to the download procedure For detailed information about how to download to an OS, please refer to the "Downloading a project and configuring changes > How to download to an individual OS" section of the PCS 7 Process Control System; Operator Station manual.

Page 39: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 39

Completing configuration on the OS Web server 88.1 Overview of Configuration Tasks

Overview The following table provides an overview of the configuration tasks on the PCS OS Web server. Step Where? What? 1 OS Web server Check settings in the User Administrator once the project has been

downloaded onto the OS Web Server (Page 40) 2 OS Web Server In the case of an OS multi-user system: Check that graphics process

mode has been deactivated in the "Computer properties" dialog box. (Page 37)

3 OS Web Server Run the Web Configurator (Page 41)

Web Configurator In the Web Configurator set up the website for the Web Client access. The Web Configurator is located in WinCC Explorer in the shortcut menu of the Web Navigator editor.

Page 40: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Completing configuration on the OS Web server 8.2 Checking the settings for the OS Web server

OS Web Option (V7.1) 40 Function Manual, 03/2009, A5E02122475-01

8.2 Checking the settings for the OS Web server

8.2.1 How to Check the Settings after Downloading

Procedure Check the following settings once you have downloaded the project from the engineering station (ES) to the OS Web Server: 1. In the User Administrator editor for the currently active OS Web Server, check that the

settings configured on the ES have transferred correctly. 2. In the PC editor for the currently active OS Web Server, open the "Computer properties"

dialog box and go to the "Startup" tab. Check whether "Graphics runtime" has been deselected in the "Order when starting WinCC runtime" group. If necessary, deactivate this option.

Note In the case of an OS single station system, there is no need to deselect "Graphics runtime".

Page 41: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Completing configuration on the OS Web server 8.3 Configuration of the Web page

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 41

8.3 Configuration of the Web page

8.3.1 Using the Web Configurator

Role of the Web Configurator The Web Configurator can be used to set up and manage the Internet Information Service (IIS) and, therefore, in turn the OS Web Server website. This has to be set up on the OS Web Server after you have downloaded the project onto the OS Web Server. This setup and configuration process is necessary for the purpose of configuring an operating station (OS) as an OS Web Server and making it accessible to the Web Clients over the Intranet/Internet. You can use the Web Configurator to make the necessary firewall settings for the network card (assuming that you have activated the firewall).

Using the Web Configurator The Web Configurator is used: ● Whenever a new OS Web Server is installed (as a general rule) ● Whenever there is a change of project ● Whenever new SIMATIC PCS 7 components are installed or existing ones are updated

8.3.2 Calling up the OS Web Navigator start screen

Calling up the OS Web Navigator start screen The call up of the OS Web Navigator start screen is specified in the Web Configurator during the initial configuration. There are two options for calling up the OS Web Navigator start screen: ● Calling up the OS Web Navigator start screen using a virtual folder on an existing web

page ● Calling up the OS Web Navigator start screen as the default web page of the IIS

Note If you run the Web Configurator again without first reinstalling the OS Web Server, the dialog box in which you specify how the OS Web Navigator start screen is called up is not displayed again.

Page 42: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Completing configuration on the OS Web server 8.3 Configuration of the Web page

OS Web Option (V7.1) 42 Function Manual, 03/2009, A5E02122475-01

8.3.3 Setting options for calling up the default web page

Setting options for calling up the OS Web Navigator start screen The following table explains the setting options for calling up the OS Web Navigator start screen on the Web Client. Setting option Meaning Web page name Enter the name of the OS Web Navigator start screen.

The default web page name is "WebNavigator". • If the OS Web Navigator start screen is called via a virtual folder

in an existing Web page, the OS Web Navigator start screen is called using the following address: http://<Servername or IP address of the OS Web Server>/<Name of the Web page> for example, http://APDL254/WebNavigator or http://145.223.123.155/WebNavigator.

• If the OS Web Navigator start screen is called as a standard Web page of the IIS, the OS Web Navigator start screen is called using the following address: http://<Servername or IP address of the OS Web Server> for example, http://APDL254 or http://145.223.123.155.

In the documentation the expression "<Server address>" is used for the address with which the OS Web Navigator start screen is called up.

Port Enter the port that is to be used for accessing the Internet with the "http" protocol here. This must be a number within the range of 1 to 65535. As a general rule, port numbers up to 1024 are pre-assigned by the system. This field is set to the HTTP port number 80 by default.

IP address Here select the OS Web Server IP address through which the Web Clients communicate with the OS Web Server.

Standard web page selection box

Use this option to select the web page that is to be displayed in Internet Explorer when the OS Web Server is accessed from the Web Clients: • If you select "MainControl.asp" (default setting), operator control

and monitoring within process pictures will be enabled. A menu bar will also be displayed in Internet Explorer on each Web Client. You can use the menu bar to select and install the components required by the Web Client.

If you do not want the menu bar (navigation bar) to be displayed to Web Client users once the plug-ins have been downloaded, run the Web Configurator again, but this time select the "Webclient.asp" setting.

To redisplay the menu bar, a user with administrative rights can call the project start page by entering the following address in Internet Explorer: http://<serveraddress>/maincontrol.asp

• If you select "Webclient.asp", operator control and monitoring within process pictures will be enabled. However, no menu bar will be made available.

Page 43: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Completing configuration on the OS Web server 8.3 Configuration of the Web page

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 43

Setting option Meaning Reconnection interval Use this option to enter the time interval that should elapse before

the Web Clients attempt to reconnect automatically following a connection fault. Set the value to 0, if you wish to deactivate the "Reconnect automatically" function.

Launch website following configuration

Select this option to launch the web page automatically after configuration. If you decide not to select this option, you will only be able to launch the website and IIS manually via Window Administration.

Page 44: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Completing configuration on the OS Web server 8.3 Configuration of the Web page

OS Web Option (V7.1) 44 Function Manual, 03/2009, A5E02122475-01

8.3.4 How to set the default web page for the Web Clients

Requirements for a multiple station project ● The OS Web Server must be installed on the OS Client. ● The project must have been downloaded from the ES onto the OS Client (OS Web

Server). ● The OS settings must have been fully checked and the pictures published. ● The user who is logged onto the OS Web Server must have been granted Internet

Information Service (IIS) configuration rights.

Requirements for an OS single station system ● The OS Web Server must be installed on the OS single station system. ● With an OS single station system (OS single station), the project must have been

downloaded from the ES onto the OS single station system. ● The OS settings must have been fully checked and the pictures published. ● The user who is logged onto the OS Web Server must have been granted Internet

Information Service (IIS) configuration rights.

Procedure 1. Open the project in the WinCC Explorer on the OS Web Server. 2. Select the "Web Navigator" editor. 3. Select the Web Configurator context menu item.

The "WinCC Web Configurator" dialog box is opened. 4. Click "Next". 5. Select one of the following options:

– Activate the "Create a new standard Web site (stand-alone)" check box. – Activate the "Add to an existing Web site (virtual folder)" check box.

6. If you have activated the "Create a new standard Web site (stand-alone)" check box, continue with Step 9.

7. If you have activated the "Add to an existing Web site (virtual folder)" check box, use the "Browse" button to select the active web page in which the virtual folder is to be inserted.

8. Click "OK". 9. Click "Next". 10. Enter the name of the web page in the "Name of the Web site:" input field. 11. Enter the port in the "Port:" input field. 12. Enter the IP address in the "IP address:" input field. 13. Enter the default web page in the "Default Web-Page:" input field. 14. Enter the reconnection interval in the "Reconnect Interval:" input field.

Page 45: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Completing configuration on the OS Web server 8.3 Configuration of the Web page

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 45

15. Activate the "Start the web-site after being configured." check box. 16. If you have not activated the Windows Firewall, continue with Step 18. 17. If you have activated the Windows Firewall, proceed as follows:

– Click the "Windows Firewall" button. This button is only visible if the Firewall is active. The "Windows Firewall" dialog box is opened.

– Select the "Advanced" tab. – Select the check box for the desired network connection. – Click "Settings ...".

The "Advanced settings" dialog box opens. – Select the "Secure Web Server (HTTPS)" and/or "Web server (HTTP)" check box. – Click "OK".

18. Click "Finish". 19. Click "OK".

You can ignore the subsequent message that will recommend a PC restart.

Result The IIS is restarted. The created web page is activated.

Page 46: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Completing configuration on the OS Web server 8.3 Configuration of the Web page

OS Web Option (V7.1) 46 Function Manual, 03/2009, A5E02122475-01

Page 47: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 47

Installations and Settings for the Web Client 99.1 Preparations

Preparations In order to use the Web Client for process control purposes, you will first need to carry out the following preparations on the PC: ● Check the Internet Explorer settings to see whether the plug-ins can be installed. ● Install the "Web Client" application on the PC that you want to serve as a Web Client. ● You will need to download the relevant plug-ins from the OS Web Server.

Note In order to install the Web Client and plug-ins you will need to have main user rights for the Web Client PC (as a minimum).

Page 48: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.2 Overview of the Installation Procedure

OS Web Option (V7.1) 48 Function Manual, 03/2009, A5E02122475-01

9.2 Overview of the Installation Procedure

Installation steps To install and configure the Web Client, you will need to carry out the steps below. These steps are described in detail in the sections that follow. Where? What? Internet Explorer on Web Client Internet Explorer settings (Page 49) Internet Explorer on Web Client Install Web Client on your PC (Page 51) Internet Explorer on Web Client Install plug-ins (Page 53) Internet Explorer on Web Client Start process control on the Web Client (Page 55) Internet Explorer on Web Client Set the language for the navigation bar (Page 56) Control Panel on Web Client Remove and modify/update plug-ins on the Web Client

(Page 56)

Page 49: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.3 Internet Explorer settings

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 49

9.3 Internet Explorer settings

9.3.1 Setting the Web content zone

Web content zones You need to make/check Web content zone settings in Internet Explorer so that you can download plug-ins for the Web Client from the OS Web Server later on.

9.3.2 How to set the "Internet" or "Local Intranet" Web content zones

Requirement Internet Explorer must be installed.

Procedure 1. Open Internet Explorer. 2. Select Tools > Internet Options. 3. Select the "Security" tab. 4. Select the Web content zone that contains the OS Web Server (either "Internet" or "Local

intranet"). 5. Click the "Custom Level" button. 6. Under "Script ActiveX controls marked safe for scripting" and "Download signed ActiveX

controls", click "Enable". 7. Click "OK" to close the "Security Settings" dialog box. 8. Click "OK" to close the "Internet Options" dialog box.

Result The necessary conditions for establishing a connection between the Web Client and OS Web Server have now been created.

Page 50: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.3 Internet Explorer settings

OS Web Option (V7.1) 50 Function Manual, 03/2009, A5E02122475-01

9.3.3 How to set the "Trusted Sites" web content zone

Introduction You need to make/check the following settings in Internet Explorer so that you can download plug-ins for the Web Client from the OS Web Server later on.

Requirement Internet Explorer must be installed.

Procedure 1. Open Internet Explorer. 2. Select Tools > Internet Options. 3. Select the "Security" tab. 4. Select the "Trusted sites" icon. 5. Click the "Sites" button.

The "Trusted sites" dialog box opens. 6. Enter the address of the OS Web server in the input box "Add this Web site to the zone".

Possible formats and wildcards include, for example: *://157.54.100 – 200, ftp://157.54.23.41, or http://*.microsoft.com.

7. Deactivate the "Require server verification (https:) for all sites in this zone" box. 8. Click "Add".

This adds the address of the OS Web server. 9. Click "OK". 10. Select the "Trusted sites" icon. 11. Click the "Standard level" button. 12. Click the "Custom Level" button. 13. In the "Security Settings" dialog box, select "Enable" under "Initialize and script ActiveX

controls not marked as safe". 14. Click "OK". 15. Click "OK" to close the "Internet Options" dialog box.

Result The necessary conditions for establishing a connection between the Web Client and OS Web Server have now been created.

Page 51: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.4 How to Install the Web Client on Your PC

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 51

9.4 How to Install the Web Client on Your PC

Installation options You have two options when installing the "Web Client" software package: ● Remote installation from the OS Web Server using the Intranet/Internet ● Local installation on the Web Client using the Windows Installer Package: Client type Remote installation method Local installation method Web Client on OS multiple station system

X X

Web Client on OS single station system

X X

Web Diagnostics Client on OS single station system

X

Remote installation The following instructions explain the remote installation method.

Requirements ● The project must have been downloaded onto the OS Web Server.

The relevant OS (WinCC Explorer) must have been opened. ● The PC that is going to be used as the Web Client must be able to access the OS Web

Server. The relevant OS (WinCC Explorer) must have been opened.

● You know the <serveraddress> of the OS Web server. ● You must know the domain, a user name and the associated password. ● You must have been granted user rights for PCS 7 Web Option in the User Administrator

on the OS Web Server. ● You must have main user rights for the PC as a minimum.

Page 52: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.4 How to Install the Web Client on Your PC

OS Web Option (V7.1) 52 Function Manual, 03/2009, A5E02122475-01

Procedure 1. Open Internet Explorer. 2. Enter http://<serveraddress> in the "Address" input box.

For information about the server address, refer to the section "Setting options for calling up the OS Web Navigator start screen (Page 42)".

3. Enter your WinCC user name and password in the "Enter network password" dialog box. If you want the PC to remember your password check the "Save password" box. The first time you connect to the OS Web Server, the "Security prompt" dialog box will appear.

4. Click "Install" in the "Security prompt" dialog box. The OS Web Server start page is displayed in Internet Explorer. The start page that is actually displayed will depend on the default Web page setting. For additional information, please refer to the section titled "Setting options for calling up the OS Web Navigator start screen (Page 42)".

5. In the main window, select "Click here to install". The installation wizard will start up. This will then guide you through the process of installing the "Web Client" application on your PC.

6. In the "File download" dialog box, click "Open" to start using the installation wizard. – Work through the installation wizard until you get to the "Customer information" dialog

box. Enter your user name and the name of your company. 7. Select the type of installation:

– Select the "Complete" check box to install all the necessary components. We recommend the "Complete" installation option.

– Select the "Custom" check box if you wish to select the individual components that you want to be installed. Now follow the instructions provided by the wizard.

8. Click "Install" to start the installation process. 9. Click "Finish" to complete the installation process.

Result Once the "Web Client" application has been installed, a dialog box will be displayed in Internet Explorer that lists all the components that have been installed, along with details of their size and version. Do not click "Process pictures" yet, as you will first need to install the plug-ins.

Installing the "Web Client" software package locally The installation on a Web Client is carried out using the general setup routine on the PCS 7 Toolset DVD.

Installing the "Web Diagnostics Client" software package locally The installation on a Diagnostics Web Client is carried out using the general setup routine on the PCS 7 Toolset DVD.

Page 53: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.5 How to Install Plug-ins

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 53

9.5 How to Install Plug-ins

Introduction To enable operator control and monitoring of faceplates in process pictures on the Web Client or the Web Diagnostics Client, you first need to install the plug-ins that will make the faceplates operable over the Internet.

Requirements ● The Web Client or Web Diagnostics Client must be installed on your PC. ● The WinCC project must have been opened on the OS Web Server. ● Internet Explorer will either display the OS Web Server start page or the results page of

the Web client software installation process. ● To set the default Web page for the Web clients, "MainControl.asp" needs to be selected

in the default Web page list box.

Procedure 1. In Internet Explorer, hover your mouse over the left-hand edge of the window to access

the navigation bar and display the main menus. 2. In the main menu, click the double arrow next to the name or IP address of the OS Web

Server to display the submenus. 3. Click the "Download area" submenu to access the download area. 4. Click "Download plug-ins" in the download area.

All the plug-ins that are available for the Web Client will be displayed on the right-hand side of the Internet Explorer window. In addition, the size and status information will be provided along with buttons for installing them.

Page 54: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.5 How to Install Plug-ins

OS Web Option (V7.1) 54 Function Manual, 03/2009, A5E02122475-01

5. Click in the "Install" column on the version information arrow to install the following plug-ins one after the other: – WinCC Basic Process Control – WinCC Advanced Process Control – PCS 7 Faceplates – PCS 7 Advanced Faceplates Note: The "WinCC Basic Process Control" plug-in has to be installed prior to the "WinCC Advanced Process Control" plug-in. Installing these plug-ins provides you with the basic functions for operator control and monitoring without SIMATIC BATCH, SFC and SIMATIC Route Control.

6. Click on the arrow with the specified version in the "Install" column to install the following plug-ins one after the other. The following plug-ins provide you with additional operator control functions for SIMATIC BATCH and SFC visualization if they are installed. – Microsoft MSXML 6.0 – SIMATIC BATCH WinCC Options – SIMATIC ES Common Services – SIMATIC SFC Common Displays – SIMATIC SFC Visualization – SIMATIC Route Control

Result The Web Client installation process is now complete. Close Internet Explorer and then reopen it to log onto the OS Web Server for the purpose of process control. As soon as you activate OS Web Server runtime (process mode) on the OS Web Server, you will be able to access the process pictures on the Web Client.

Page 55: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.6 How to Start Process Control on the Web Client

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 55

9.6 How to Start Process Control on the Web Client

Introduction Once you have installed all the necessary plug-ins on your Web Client, you can start process control.

Requirement The OS on the OS Web Sever must have been started up in process mode.

Procedure 1. Open Internet Explorer. 2. Enter http://<Server address> in the input field "Setting options for calling up the

OS Web Navigator start screen (Page 42)".

Result The start screen that has been specified on the OS Web Server in the User Administrator is displayed in Internet Explorer. If the "MainControl.asp" option has been selected in the standard website selection box for the Web Client standard website setting, the navigation bar will be displayed. The navigation bar is minimized to provide the maximum amount of space for the start screen display area. For additional information about displaying the navigation bar refer to the section "Setting options for calling up the OS Web Navigator start screen (Page 42)".

Page 56: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.7 How to Set the Language for the Navigation Bar on the Web Client

OS Web Option (V7.1) 56 Function Manual, 03/2009, A5E02122475-01

9.7 How to Set the Language for the Navigation Bar on the Web Client

Introduction To adapt the navigation bar language setting in Internet Explorer for the Web Client, proceed as described below.

Requirements ● The WinCC project must have been opened on the OS Web Server. ● To set the standard website for the Web Clients, "MainControl.asp" needs to be selected

in the standard website selection box.

Procedure 1. Open the navigation bar in Internet Explorer. 2. In the main menu, select Language > <Flag>.

Result The navigation bar is switched over to the desired language.

9.8 Removal and retro-installation/Update incl. plug-ins on the Web client

9.8.1 Removal and Retro-installation/Update of Plug-ins on the Web Client

Notes on removing and modifying installed products You can only remove the Web Client and plug-ins via Start > Settings > Control Panel > Add or Remove Programs. The process for modifying/updating products is similar to the one for installing them for the first time: ● When you log onto the OS Web Server in Internet Explorer, the versions of all the

components installed on the Web Client are compared with the versions stored on the OS Web Server. If a more recent version is available on the OS Web Server, an update will be made available to the Web Client.

● You can install new plug-ins at any time via the Web download menu. For additional information, please refer to the section "How to install plug-ins (Page 53)".

Page 57: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.9 Web Client functions in process mode

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 57

9.9 Web Client functions in process mode

9.9.1 Web Client user interface

User interface On a Web Client, it is always the layout that was configured on the OS Web server that will be used and displayed. Operator control and monitoring of the process pictures displayed on the Web Client is exactly the same as with an operating station (OS), provided that the operator who is logged on has been assigned the relevant rights. The Web Client user interface is structured in exactly the same way as on an operating station (OS). It is made up of an overview area, a workspace and a key set area. The main difference is that the user interface is displayed in Internet Explorer. Also, some of the functions associated with key sets 1 and 2 that would normally be accessible on an operating station (OS) are not available.

NOTICE If the WinCC Picture Tree is derived from the SIMATIC Manager plant hierarchy, or if the names of the OS areas in the plant hierarchy and WinCC Picture Tree are consistent, you will be able to use process pictures.

Page 58: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.9 Web Client functions in process mode

OS Web Option (V7.1) 58 Function Manual, 03/2009, A5E02122475-01

9.9.2 Functionality on the Web Client

Introduction In process mode, the Web Client offers functions in the following areas of the OS screen: ● Overview area ● Workspace and process picture area ● Key sets

Overview area The following functions are available in the overview area: ● Select process pictures from the Picture Tree Navigator ● "Loop-in-alarm" function using group displays ● "Screen printout" function

Note If the message line and area selection keys fail to display correctly in the overview area when you connect to the process control start screen for the first time, try refreshing the display in Internet Explorer by selecting View > Refresh. If you click an area selection key but the screen does not change in the workspace, try selecting View > Refresh in Internet Explorer. This menu item requests and displays the latest data from the OS Web Server.

Key sets The key sets offer message system and navigation functions. The navigation functions for browsing through the picture hierarchy will still be visible even if no process picture can be selected.

Page 59: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.9 Web Client functions in process mode

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 59

Workspace and process picture area ● For the purpose of controlling and monitoring the process, you can use all of the objects

that have been configured on the PCS 7 OS (PCS 7 faceplates and standard/smart and Windows objects).

● To enable SFC Visualization to run on the Web Client, the SFC block icon and SFC faceplate functions have already been implemented. You cannot yet use the "Section" and "Overview" keys.

● You can use all of the SIMATIC BATCH faceplates apart from the "BATCH control center" button.

● The following buttons are not available with the SIMATIC Route Control faceplate: – "BCC", "SFC", "RCC", "Close" and "Help"

● Within the workspace, you can check which area is currently active by looking to see which process picture is being displayed.

● If you open an active SFC instance on a Web Client, it is the "Prepared values" view that will be displayed and not the "Current values" view, which is the one that would be displayed in the case of an OS Client. You can select the desired view from a drop-down list box.

● The following functions cannot be executed in the "Diagnostics" OS area: – Filtering on the complete export – Calling up the hardware project (HW Config) – Call up the configuration data – Displaying the "Parameters view and the "Chg. Report" view – Printing from the "Maintenance" view

● The Web Client does not support operation via hotkeys configured in WinCC, because Internet Explorer is not capable of distinguishing between its own internal operating objects (e.g., the "Refresh" button) and those of WinCC.

Additional information ● Section titled ""BPC" and "APC" Supported Functions" (Page 65) ● Section titled "Supported Functions" in the online help Web Navigator Information System ● Section titled "Non-supported functions" in the online help Web Navigator Information

System

Page 60: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Installations and Settings for the Web Client 9.9 Web Client functions in process mode

OS Web Option (V7.1) 60 Function Manual, 03/2009, A5E02122475-01

Page 61: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 61

Time 1010.1 Time-of-day displays on the Web Client

Introduction If the Web Clients and OS Web Server are located in different time zones, the times displayed on the Web Clients will differ. The Web Client time of day is not synchronized on a PCS 7 system.

Times of day displayed on the Web Client without time-of-day synchronization If a Web Client is located in a different time zone from the OS Web Server, the following times of day will be displayed: ● The time of day in the overview area corresponds to the local Web Client time. ● The time of day for the trend values is based on local OS Web Server time. ● The time of day for the messages is based on local OS Web Server time. ● The time of day used for acknowledgement is based on local OS Web Server time.

The time of day used for acknowledgement messages is based on local OS Web Server time.

● The time of day used for process value operation is based on local Web Client time. The time of day used for operator messages is based on local OS Web Server time.

Page 62: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Time 10.2 Web Client time-of-day synchronization

OS Web Option (V7.1) 62 Function Manual, 03/2009, A5E02122475-01

10.2 Web Client time-of-day synchronization

Time-of-day displays on the Web Client If the Web Client and OS Web Server are located in different time zones, the times displayed on the Web Client will differ. For additional information, please refer to the section titled "Time-of-day displays on the Web Client (Page 61)".

Time-of-day synchronization on the Web Client To ensure that the time stamps are correct, operate the Web Client: ● In a domain ● With UTC (Coordinated Universal Time)

Time-of-day synchronization in a domain using a domain controller If the Web Client is located in the same domain as the OS Web Server, the time of day is synchronized via the domain's domain controller.

Web Client relies on UTC Internally, the PCS 7 system relies on UTC. Time information that is to be displayed for the operator in process mode can be converted into the local geographical time by UTC.

Page 63: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 63

Getting status information 1111.1 Status Information about OS Web Server and Web Clients

Status information You can call status information about the OS Web Server and Web Clients from any PC that has access to the OS Web Server. The status information tells you which users are accessing which Web Clients on the OS Web Server. The status information is displayed on the HTML page in blocks: There is an information block for the OS Web Server and there are also separate information blocks for each connected Web Client. The following information is displayed: ● Software version of the OS Web Server that is installed ● Number of Web Clients accessing the OS Web Server ● User and log-in details for each user plus information about which Web Client they are

logged onto The information blocks can only be displayed in English. To be able to call the status pages, you must be set up as a user in the WinCC User Administrator.

Page 64: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Getting status information 11.2 How to Display Status Information

OS Web Option (V7.1) 64 Function Manual, 03/2009, A5E02122475-01

11.2 How to Display Status Information

Requirements ● The user must be set up in the User Administrator. ● The "status.html" page must be called from a PC.

Procedure 1. Open Internet Explorer on an OS Web Server or a Web Client. 2. Enter http://<Server address>/status.html in the "Address" input field.

For information about the server address refer to the section "Setting options for calling up the OS Web Navigator start screen (Page 42)".

3. Enter your logon name and your password in the "Establish connection to <Computer name>" dialog box.

Note If the Web Client is installed, you can also call the status bar via the navigation bar by selecting "<PC name> > Diagnostics > Status".

Result The status information will be displayed for you on the website.

Page 65: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 65

Appendix 1212.1 Supported Functions "BPC" and "APC"

Introduction The following table lists the functions that are supported by PCS 7 OS Web Option once the following plug-ins have been installed on the Web Client: ● WinCC Basic Process Control (BPC) ● WinCC Advanced Process Control (APC)

Note The "WinCC Basic Process Control" plug-in has to be installed prior to the "WinCC Advanced Process Control" plug-in.

Supported functions The following list of supported functions tells you how to configure your project on the ES so that it can be run as a web project on the Web Client. Certain functions are marked with an "(*)". These functions are included in the functional scope in order to ensure error-free compiling on the Web Navigator Client. These functions are not supported by the Web Client. No. Functions in SIMATIC PCS 7 Plug-in Instrumentation and control option standard functions: 1 GetCSigPicture BPC plug-in 2 GetSignificantMask BPC plug-in 3 PASSCheckAreaLevelPermission BPC plug-in 4 PASSCheckAreaPermission BPC plug-in 5 PASSCheckLevelPermission BPC plug-in 6 PASSLoginDialog (*) BPC plug-in 7 SFCOpen (*) BPC plug-in 8 LockAreaMessages BPC plug-in 9 LoopInAlarm BPC plug-in 10 void GetServerTagPrefix(char** ppszServerPrefix, char**

ppszTagPrefix); Web Navigator Basic

Page 66: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Appendix 12.1 Supported Functions "BPC" and "APC"

OS Web Option (V7.1) 66 Function Manual, 03/2009, A5E02122475-01

No. Functions in SIMATIC PCS 7 Plug-in Split screen manager standard functions: 11 AcknowledgeAllPicture (*) BPC plug-in 12 ALGAcxAddPermissionFilter BPC plug-in 13 ALGAcxAddPermissionFilterShow BPC plug-in 14 PTN_CSIG_Ldown BPC plug-in 15 PTN_CSIG_RDOWN BPC plug-in 16 PTN_CSIG_RUP BPC plug-in 17 PTN_NODE_LDOWN BPC plug-in 18 PTN_NODE_RDOWN BPC plug-in 19 PTN_OpenPath BPC plug-in 20 PTN_PICT_CHANGE BPC plug-in 21 PTN_PICT_LDOWN BPC plug-in 22 RemovePrefix BPC plug-in 23 SSMChangeButtonField BPC plug-in 24 SSMChangeOverviewField BPC plug-in 25 SSMChangeWorkField BPC plug-in 26 SSMCheckAreaLevelPermission BPC plug-in 27 SSMCheckWorkFieldDown BPC plug-in 28 SSMCheckWorkFieldLeft BPC plug-in 29 SSMCheckWorkFieldRight BPC plug-in 30 SSMCheckWorkFieldUp BPC plug-in 31 SSMChgWorkFieldDown BPC plug-in 32 SSMChgWorkFieldLeft BPC plug-in 33 SSMChgWorkFieldRight BPC plug-in 34 SSMChgWorkFieldUp BPC plug-in 35 SSMGetAreaFromIndex BPC plug-in 36 SSMGetAreaFromPath BPC plug-in 37 SSMGetAreaFromWorkField BPC plug-in 38 SSMGetButtonColor BPC plug-in 39 SSMGetContainer BPC plug-in 40 SSMGetContainerIDToPicture BPC plug-in 41 SSMGetContainerToPicture BPC plug-in 42 SSMGetContPict BPC plug-in 43 SSMGetIndexFromObject BPC plug-in 44 SSMGetIndexObjectName BPC plug-in 45 SSMGetRegistryString BPC plug-in 46 SSMGetRootToPicture BPC plug-in 47 SSMGetSAPictureNameEx BPC plug-in 48 SSMGetScreen BPC plug-in 49 SSMGetWorkFieldCoordinates BPC plug-in 50 SSMGetWorkFieldPath BPC plug-in

Page 67: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Appendix 12.1 Supported Functions "BPC" and "APC"

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 67

No. Functions in SIMATIC PCS 7 Plug-in 51 SSMGetWorkFieldPicture BPC plug-in 52 SSMHardCopy BPC plug-in 53 SSMIsUserNameEnable BPC plug-in 54 SSMIsVariableValid BPC plug-in 55 SSMLinkCSIG BPC plug-in 56 SSMOpenSpecField BPC plug-in 57 SSMOpenTopField BPC plug-in 58 SSMOpenTopFieldFixedSize BPC plug-in 59 SSMSetAreaNameToPicture BPC plug-in 60 SSMShowAreaButtonEx BPC plug-in 61 SSMShowTreeEx BPC plug-in 62 SSMProgramStart BPC plug-in 63 SSMProgramExecute BPC plug-in 64 SSMGetSAPictureName BPC plug-in 65 GetCountPicture BPC plug-in 66 SSMPictureStoreSet BPC plug-in 67 SSMPictureStoreNum BPC plug-in 68 SSMPictureStoreGet BPC plug-in 69 SSMPictureMemoryNum BPC plug-in 70 SSMPictureMemoryRestore BPC plug-in 71 SSMPictureMemoryInquire BPC plug-in 72 SSMGetServerEx BPC plug-in 73 SSMMCActualButtonEx BPC plug-in 74 SSMMCCalcCSIGEx BPC plug-in 75 SSMMCChangeAreaEx BPC plug-in 76 SSMMCChangeServer BPC plug-in 77 SSMMCShowTreeEx BPC plug-in 78 SSMShowAreaTextMCEx BPC plug-in 79 SSMGetSAPictureAndObjectNameEx BPC plug-in 80 SSMScrollPictureToObject BPC plug-in 81 GetPictObj BPC plug-in

Page 68: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Appendix 12.1 Supported Functions "BPC" and "APC"

OS Web Option (V7.1) 68 Function Manual, 03/2009, A5E02122475-01

No. Functions in SIMATIC PCS 7 Plug-in SSMAreaStore.dll functions: 82 Init BPC plug-in 83 SetAreaToWorkField BPC plug-in 84 GetAreaFromWorkField BPC plug-in 85 SetAreaToTopField BPC plug-in 86 GetAreaFromTopField BPC plug-in 87 SetStyleToTopField BPC plug-in 88 GetStyleFromTopField BPC plug-in 89 SetPictureToTopField BPC plug-in 90 GetPictureFromTopField BPC plug-in 91 GetAvailableTopField BPC plug-in 92 SetPictureToWorkField BPC plug-in 93 GetPictureFromWorkField BPC plug-in 94 GetMaxTopfieldNo BPC plug-in ssmrt.dll functions: 95 SSMRTGetAreaFromPicturePath BPC plug-in 96 SSMRTGetConfigLong BPC plug-in 97 SSMRTSetConfigLong BPC plug-in 98 SSMRTGetConfigString BPC plug-in 99 SSMRTSetConfigString BPC plug-in 100 SSMRTGetAreaButtonByIndex BPC plug-in 101 SSMRTGetALGFilter BPC plug-in 102 SSMRTGetALGAdmimFilterLevel BPC plug-in 103 SSMRTGetALGViewFilterLevel BPC plug-in 104 SSMRTGetNoAreaEntry BPC plug-in 105 SSMRTGetAlarmpageConf BPC plug-in 106 SSMRTGetAvailableTopFieldNo BPC plug-in 107 SSMRTGetBaseNames BPC plug-in 108 SSMRTGetWorkFieldCoordinates BPC plug-in 109 SSMRTGetPicturePathInfo BPC plug-in 110 SSMRTGetRegistryString BPC plug-in

Page 69: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Appendix 12.1 Supported Functions "BPC" and "APC"

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 69

No. Functions in SIMATIC PCS 7 Plug-in ptm_api.dll functions: 111 PTMRTGetRootNode BPC plug-in 112 PTMRTGetParentNode BPC plug-in 113 PTMRTGetFirstChildNode BPC plug-in 114 PTMRTGetLeftBrotherNode BPC plug-in 115 PTMRTGetRightBrotherNode BPC plug-in 116 PTMRTGetAreaNode BPC plug-in 117 PTMRTGetNode BPC plug-in 118 PTMRTGetNodeIndex BPC plug-in 119 PTMRTGetNodeEx BPC plug-in 120 PTMRTGetAreaNodeEx BPC plug-in tagtable.dll functions: 121 TAGTABLEReadVar APC plug-in 122 TAGTABLEReadVarEx APC plug-in 123 CSigAPIGetCountPicture APC plug-in 124 CSigAPIAcknowledgePicture APC plug-in 125 CSigAPILockMessage APC plug-in 126 CSigAPILockMessages APC plug-in 127 CSigAPIGetCountPicture APC plug-in 128 TAGTABLEReadVar APC plug-in 129 TAGTABLEReadVarEx APC plug-in CsigAPI.dll functions: 130 CSigAPIGetCountPictureAndObject APC plug-in 131 CSigAPIAcknowledgeTagAndCreateLTM APC plug-in

Additional information For additional information about the functions refer to the section "Supported functions" and to the section "Non-supported functions" in the Web Navigator Information System Online Help.

Page 70: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Appendix 12.1 Supported Functions "BPC" and "APC"

OS Web Option (V7.1) 70 Function Manual, 03/2009, A5E02122475-01

Page 71: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 71

Index

A Access rights, 35

For Web Client, 35 Additional documentation, 9 APC, 65

Functions supported by PCS 7 OS Web Option, 65 Asset management, 58

B Basic knowledge, 5 BPC, 65

Functions supported by PCS 7 OS Web Option, 65

C Calling, 5, 64

Documentation, 5 Status information for Web Client/Server, 64

Checking, 40 Settings following a download, 40

Configuration, 22 OS Web Diagnostics Server, 22 Web Diagnostics Client, 22

Configuration on a multiple station system, 18 OS Web Server, 18 Web Client, 18

Configuration on a single station system, 20 OS Web Standard Server, 20 Web Standard Client, 20

Configuration tasks, 29, 39 OS Web server, 39 OS Web Server, 29

Configurations, 17 Configuring, 49, 50

Internet Explorer for Web Client, 49

D Data

Publish, 32 Deactivating, 37

Graphics process mode, 37 Default Web page, 42

Setting options for Web Client, 42 Disabling, 37

Graphics process mode, 37 Documentation, 5, 9

Additional ~, 9 Call, 5

Downloading, 38 OS Web Server, 38

F Function overview, 11

PCS 7 OS Web Option, 11 Functions, 30, 58

On the OS Web Client, 58 Supported ~ by PCS 7 OS Web option, 30

Functions supported by PCS 7 OS Web Option, 65 WinCC Advanced Process Control, 65 WinCC Basic Process Control, 65

G General setup routine, 27

OS Web Server, 27 Graphics process mode, 37

Deactivate, 37

H Hardware requirements, 25, 26

OS Web Client, 26 OS Web Server, 25

I Installation requirements, 27

OS Web Server, 27 Installing, 51, 53

OS Web Client on PC, 51 Plug-in, 53

Internet Explorer, 49, 50 Configure on Web Client, 49, 50

M Maintenance station, 58

Page 72: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Index

OS Web Option (V7.1) 72 Function Manual, 03/2009, A5E02122475-01

Modifying, 56 Plug-in on the OS Web Client, 56

N Navigation bar, 56

Set language, 56 Normal functions, 30

Supported ~ by PCS 7 OS Web option, 30

O OS system, 35

Restricting access by the Web Client, 35 OS Web Client

Call status information, 64 Hardware requirements, 26 Install on PC, 51 Perform an update, 56 Reinstalling, 56 remove, 56 Removing, 56 Retro-installation of a plug-in, 56 Set language in navigation bar, 56 Software requirements, 26 Start process control, 55 Status information, 63 Supported functions, 58 Time-of-day display, 61 User interface, 57

OS Web Navigator Start screen, 41

OS Web Server Call status information, 64 Configuration tasks, 29 General setup routine, 27 Hardware requirements, 25 Installation requirements, 27 Notes on downloading, 38 Software requirements, 25 Status information, 63

Overview of installation steps, 48

P PCS 7 OS Web Option, 11, 30

Function overview, 11 Supported script normal functions, 30 Web-executable functions, 30

Perform an update, 56 Plug-in on the OS Web Client, 56

Plug-in, 53, 56 Install, 53 Modify on OS Web Client, 56 Perform an update on the OS Web Client, 56

Preface, 5 Preparing, 47

PC as Web Client, 47 Process control, 55

Start on the OS Web Client, 55 Publishing, 31, 32

Procedure in the Web View Publisher, 32 Requirements, 31

Purpose, 30 Web View Publisher, 30

R Removing, 56

OS Web Client, 56 Requirements, 31

For publishing with Web View Publisher, 31

S Scope of the manual, 5 Script normal functions, 30

Supported ~ by PCS 7 OS Web option, 30 Set language, 56

In navigation bar on OS Web Client, 56 Setting, 35, 56

Language in navigation bar on OS Web Client, 56 User rights for Web Client, 35

Settings, 42 For the default Web page of the Web clients, 42

Software requirements, 25, 26 OS Web Client, 26 OS Web Server, 25

Starting, 55 Process control on the OS Web Client, 55

Status information, 63, 64 Call, 64 OS Web Client, 63 OS Web Server, 63

Supported functions, 58 On the OS Web Client, 58

T Time-of-day display

OS Web Client, 61

Page 73: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Index

OS Web Option (V7.1) Function Manual, 03/2009, A5E02122475-01 73

U User Administrator, 35

Set user rights for Web Client, 35 User interface, 57

OS Web Client, 57 User rights, 35

For Web Client, 35 Set for Web Client, 35

W Web Client

Configure Internet Explorer, 49 Install on PC, 51 Prepare PC as Web Client, 47 Restricting OS system access rights, 35 Set user rights in the User Administrator, 35 Setting options for default Web page, 42 Setting the language for the navigation bar, 56 Start process control, 55 Status information, 63 Supported functions, 58 User interface, 57

Web Configurator, 41 Web content zone, 49, 50 Web Server

Status information, 63 Web View Publisher, 30, 31, 32

Publish local data, 31 Publish project-specific data, 31 Publishing procedure, 32 Publishing requirements, 31 Purpose, 30

WinCC Advanced Process Control, 65 Functions supported by PCS 7 OS Web Option, 65

WinCC Basic Process Control, 65 Functions supported by PCS 7 OS Web Option, 65

Page 74: SIMATIC OS Web Option (V7.1) · 2015-01-21 · 12 SIMATIC Process Control System PCS7 OS Web Option (V7.1) Function Manual 03/2009 A5E02122475-01 . ... 31 7.2.4 Overview of the Publishing

Index

OS Web Option (V7.1) 74 Function Manual, 03/2009, A5E02122475-01