SID 2111 V2 900_Config444_RevA_2011-06-01

download SID 2111 V2 900_Config444_RevA_2011-06-01

of 40

description

SID 2111

Transcript of SID 2111 V2 900_Config444_RevA_2011-06-01

  • LZN/IPA 143 5546 Uen R1A

    Radio Site Installation DocumentationTELMA Mobile

    New GSM 900 RBS 2111V2AnosizatoPhase 1DANM058

  • CAPTION LIST Document List 1Document No.

    001 53-IPA 143 5546 UenDate Rev.

    A

    Site Drawings 2

    Site Specification 3

    Plant Specification 4

    Test Documents 7

    Product Lists 8

    Check Lists 9

    Labels 10

    Mini-Link TN

    Cabling Diagrams 6

    New GSM 900 RBS 2111V2

    Ericsson's GSM System

    B 20

    10-0

    6-29

    2011-06-01

    Phase 1D

    Anosizato

    ATTENTIONThis documentation must be updated on site. All thedocuments must be corrected, where changes have occurred, and signed by the Installation Supervisor.

    This documentation must thenbe returned to Installation Engineering for preparation of the Radio Site Design Documentation.

    SITE INSTALLATION

    DOCUMENTATION

  • DOCUMENT LISTPrepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 001 51-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    Document name Document number Rev.

    SITE INSTALLATION DOCUMENTATION LZN/IPA 143 5546 Uen R1A

    CAPTION LIST 001 53-IPA 143 5546 Uen A

    1 DOCUMENT LIST 001 51-IPA 143 5546 Uen A

    2 SITE DRAWINGSSituating Plan TELMA TSSR DRAWINGFloor Plan Drawing TELMA TSSR DRAWINGAntenna Placement Information TELMA TSSR DRAWING

    3 SITE SPECIFICATION1/127 04-IPA 143 5546 Uen A

    Configuration Data (TRM) 2/127 04-IPA 143 5546 Uen AConfiguration Data (TRM-Facing Site) 3/127 04-IPA 143 5546 Uen A

    4 PLANT SPECIFICATION1/127 11-IPA 143 5546 Uen A

    Plant Specification (TRM) Near site 2/127 11-IPA 143 5546 Uen APlant Specification (TRM) Facing site 3/127 11-IPA 143 5546 Uen A

    5 ALLOCATION DOCUMENTSAllocation table : Alarms 4/193 19-IPA 143 5546 Uen AAllocation Drawing : cabinets 193 26-IPA 143 5546 Uen A

    6 CABLING DIAGRAMSCable Distribution Diagram (Signal and Power) 1/193 18-IPA 143 5546 Uen ACable Distribution Diagram (Antenna cabling) 2/193 18-IPA 143 5546 Uen A

    7 TEST DOCUMENTSTest Report (RBS) 1/153 83-IPA 143 5546 Uen ATest Report (TRM) 2/153 83-IPA 143 5546 Uen A

    8 PRODUCT LISTSProduct List (RBS) 1/193 32-IPA 143 5546 Uen AProduct List (TRM) 2/193 32-IPA 143 5546 Uen A

    9 CHECK LISTSSite Inspection List 1/153 11-IPA 143 5546 Uen A

    10 Labels

    A

    Configuration Data (RBS900)

    Plant Specification (RBS 900)

    B 20

    10-0

    6-29

    2011-06-01

  • Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/127 04-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    1 GENERAL SITE DATA1.1 Geographical coordinates(WGS 84) E 47 29' 49.4" S 18 56' 22.6" Alt 1254m1.2 Region Analamanga1.3 Location "Enceinte de l'Eglise Catholique Anosizato"

    Antananarivo - Madagascar1.4 Type of Site1.5 Equipment room Outdoor1.6 Ceiling material1.7 Wall material1.8 Floor material1.9 Air conditioning1.10 Contact personal "Pre Alain Michel - Prsident Hugues"

    1.11 Contact personal adress " Eglise Catholique Anosizat"1.12 Mobile number of contact 034 17 991 23 - 033 74 185 71

    2 TECHNICAL DATA RBS2.1 System2.3 No. of Cells 32.4 No. of radio cabinets/RRU 62.6 No. of Main Unit2.7 Configuration 4+4+4

    3 ELECTRICAL DATA3.1 BBS Type PBC-02 MU - PBC-02 BU3.2 AC Input Voltage 90 to 275 VAC3.3 Voltage Range for Specific Performance -48 VDC3.4 Main fuses recommended for max selectivity 10 A3.5 Maximum Power Consumption 980 W3.6 No. of battery back up hour N/A3.7 Battery back up (Ah)3.8 RRU-N Typical Power Requirement 160 W3.9 Main Unit Typical Power Requirement 10 W3.10 Fibre Cable Type for RRU-N AOF-TSR899088-CAB 02F3.11 Fibre Cable Length/RRU-N

    4 RBS ANTENNAS & FEEDERS4.1 Antenna Height (m.a.g.l.) (m) A =13.50 , B =13.50 , C = 11.844.2 Antenna Directions A = 0 , B = 120 , C = 2304.3 Elec/Mech Downtilt, deg A = 5/0 , B =5/0 , C = 2/04.4 Quantity of Antenna 3 pcs4.5 Type of Antenna A=

    B=C=

    4.6 Antenna dimensions (mm) A=B=C=

    4.7 Wind load of one antenna (m) A=B=C=

    4.8 Weight of one antenna (kg) A= 26B= 26C=

    4.9 Type of jumper 1/2"4.10 No. of jumpers 64.11 Total jumpers length / cell (m) A=4x2, B=4x2, C=4x2

    GSM 900

    N/A

    N/A

    460 N at 150 km/h

    460 N at 150 km/h

    H=2516mm W=262mm D=139mm

    26

    460 N at 150 km/h

    CONFIGURATION DATA (RBS900)

    2011-06-01

    H=2574mm W=259mm D=99mmH=2516mm W=262mm D=139mm

    N/A

    N/A

    B 20

    10-0

    6-29

    Kathrein 742 266 Dual Band 65 900/1800MHzKathrein 742 266 Dual Band 65 900/1800MHzKathrein 742 266 Dual Band 65 900/1800MHz

    Roof Top

    Cell A = 2x100m, Cell B = 2x100m, Cell C = 2x100m

    2

    N/A

  • Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/127 04-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    CONFIGURATION DATA (RBS900)

    2011-06-01B 201

    0-06

    -29

    5 ANTENNA SUPPORT STRUCTURE5.1 Type of tower/mast5.2 Tower/mast height (m.a.g.l.) 9m - 8m 5.3 Leg Profile5.4 Antenna support

    6 TRANSMISSION6.1 Existing No and type of media for PCM links 2 x E1 6.2 Upgrade No and type of media for PCM links6.3 Type of 2 Mbit/s connection in DDF 120-Ohm Balanced cable6.4 E1 cable length (m) 5mx2

    Mast

    New Mini-Link 15 TN

    O ProfilePipe

  • CONFIGURATION DATA (TRM)Prepared (also subject responsible if other) Nr - No

    BMG/OIS/S Serge Randriamanana 2/127 04-IPA 143 5546 UenDoc respons/Approved Checked Datum - Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900 Project: Phase 1DSite name: Anosizato ANM058

    1 GENERAL1.1 Geographical Coordinates E 47 29' 49.4" S 18 56' 22.6" Alt 1254m1.2 Region1.3 Location "Enceinte de l'Eglise Catholique Anosizato"

    Antananarivo - Madagascar1.4 Type of Site1.5 Type of 2Mb connection in DF Two pairs twisted cable, 120 ohm

    2 SITE DATA

    3 The following below are transmission links to far-end sites

    To Azimuth Calc RSL Path Length Mini-LinAntenna Size System TrafficSite (dBm) (km) Type & Type Config. Capacity

    HP Mbps

    To Site

    4 RADIO 4.1 Link Number ANM058 - ANM0364.2 No. of Radio 14.3 Output power (dBm)4.4 MMU 1 ID C5814.5 Radio Index(Sub-band)4.6 Frequency (MHz) 14922.754.7 Channel No. D14.8 Attenuator 04.9 Weight of radio

    5 ANTENNA5.1 No. of Antennas 15.2 Antenna Height (m)5.3 Antenna Gain (dBi)5.4 Polarization V5.5 Weight of antenna 8.3kg5.6 Max. Wind Force 190N5.7 Max. Wind Torque 50Nm5.8 Transmission cable length(m) 20

    B 20

    10-0

    6-29

    Default Gateway

    Analamanga

    OSPF Net Address

    Magazine Type Subnet Mask

    pppOSPF Net Address OSPF Subnet Mask Area ID

    25

    ANM036

    36.6

    25

    4.5kg

    15.0

    IP Address

    2011-06-01

    ANM036 118,32 ML15 TN 1+00.6-33.0 3.45

    New AMM 2p B

    2x2

    Roof Top

  • CONFIGURATION DATA (TRM)Prepared (also subject responsible if other) Nr - No

    BMG/OIS/S Serge Randriamanana 2/127 04-IPA 143 5546 UenDoc respons/Approved Checked Datum - Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900 Project: Phase 1DSite name: Anosizato ANM058

    B 20

    10-0

    6-29

    2011-06-01

    6 Power Consumption(W)6.1 Per Terminal (W)6.2 SAU (W) 06.3 Fan unit (W)6.4 Total Power Consumption(W)

    7 SOFTWARE SETUP7.1 Hop Setup, RF7.1.1 Remote Controlled Yes

    Output power7.1.2 AGC Alarm Threshold

    (dBm)

    7.2 Hop Setup, General7.2.1 Radio ID Check On7.2.2 BER Alarm 10-67.2.3 Local Control Yes7.2.4 Far End MMU ID C362

    42

    -88

    1052

  • CONFIGURATION DATA (TRM-FACING SITE )Prepared (also subject responsible if other) Nr - No

    3/127 04-IPA 143 5546 UenDoc respons/Approved Checked ` Rev. File

    A SID_ANM058_900 Project: Phase 1-2-3Site name: Tanjombato Forello ANM036

    1 GENERAL1.1 Geographical Coordinates E4731'33.2'' S1857'15,8'' Alt=1256m.1.2 Region1.3 Location Tanjombato Forello

    Antananarivo, Madagascar1.4 Type of Site tower 30m1.5 Type of 2Mb connection in DF Two pairs twisted cable, 120 ohm

    2 SITE DATA

    3 The following below are transmission links to far-end sites

    To Azimuth Calc RSL Path Length Mini-Link Antenna Size System TrafficSite (dBm) (km) Type & Type Config. Capacity

    HP Mbps

    To Site

    4 RADIO 4.1 Link Number ANM036 - ANM0584.2 No. of Radio 14.3 Output power (dBm)4.4 MMU 1 ID C3624.5 Radio Index(Sub-band)4.6 Frequency (MHz) 14502.754.7 Channel No. D14.8 Attenuator 04.9 Weight of radio

    5 ANTENNA5.1 No. of Antennas 15.2 Antenna Height (m)5.3 Antenna Gain (dBi)5.4 Polarization V5.5 Weight of antenna 8.3kg5.6 Max. Wind Force 190N5.7 Max. Wind Torque 50Nm5.8 Transmission cable length(m) 45

    2x2

    2011-06-01

    ANM058 298,31 ML15 TN 1+00.6-33.0 3.45

    AMM 20p existingIP Address

    36.6

    21

    25.0

    4.5kg

    ANM058

    OSPF Net Address pppOSPF Net Address

    25

    Area ID

    B 20

    10-0

    6-29 BMG/OIS/S Serge Randriamanana

    Default Gateway

    OSPF Subnet Mask

    BMG/OIS/S Haja Paul Ravaloniaina

    Greenfield

    Antsimondrano

    Magazine Type Subnet Mask

  • CONFIGURATION DATA (TRM-FACING SITE )Prepared (also subject responsible if other) Nr - No

    3/127 04-IPA 143 5546 UenDoc respons/Approved Checked ` Rev. File

    A SID_ANM058_900 Project: Phase 1-2-3Site name: Tanjombato Forello ANM036

    2011-06-01B 201

    0-06

    -29 BMG/OIS/S Serge Randriamanana

    BMG/OIS/S Haja Paul Ravaloniaina

    6 Power Consumption(W)6.1 Per Terminal (W)6.2 SAU (W) 06.3 Fan unit (W)6.4 Total Power Consumption(W)

    7 SOFTWARE SETUP7.1 Hop Setup, RF7.1.1 Remote Controlled Yes

    Output power7.1.2 AGC Alarm Threshold

    (dBm)

    7.2 Hop Setup, General7.2.1 Radio ID Check On7.2.2 BER Alarm 10-67.2.3 Local Control Yes7.2.4 Far End MMU ID C581

    42

    -88

    1052

  • PLANT SPECIFICATION (RBS)Prepared (also subject responsible if other) Document No.BMG/OIS/S Serge Randriamanana 1/127 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. FileBMG/OIS/S Haja Paul Ravaloniaina 2011-06-01 A SID_ANM058_900

    Project Phase 1DSite: Anosizato ANM058

    ITEM Product Name Product Code Unit Request Note

    RBS 2111V2 Config 444 GSM 900

    1. RBS 2000 Equipment1.1 EQUIPPED CABINET/MU-12, RBS2111 V2 BFE899101/2 U 21.2 SET OF MATERIALS/MU WALL&POLE-MOUNTING K NTM1011278/1 Kit 21.3 L bracket MU U 0

    1.4 Kit Bolt and fisher U 0

    1.5Bolt for MU + nut (ecrou) U 0

    1.6 MATCHED TERMINATION/90 OHM TERMINATION 3 UML102033/1 U 01.7 CABLE WITH CONNECTOR/TG-SYNC CABLE 3 RPM1190408/05500 U 01.8 CABLE WITH CONNECTOR/TG-SYNC CABLE FOR R RPM1190584/05500 U 11.9 CABLE WITH CONNECTOR/TG-SYNC CABLE FOR R RPM1190584/25000 U 01.10 CONNECTION CABLE/OPTICAL FIBER (50M) TSR899088/4 U 01.11 CABLE/OPTICAL FIBER (100M) TSR899088/2 U 61.12 CABLE/OPTICAL FIBER (500M) TSR899088/3 U 01.13 TRANSCEIVER/RRUN9P-22 KRC161170/1 U 61.14 TRANSCEIVER/RRUN18-22 KRC161170/3 U 01.15 MOUNTING SET/MECHANIC FOR MAST NTM20220/1 Box 161.16 CABLE/TFL3016003/4 10M SPO TPM1010023/10M U 11.17 CABLE/EQLQ 3G2.5 MM (TEL 710 1325/2) TEL710005/50M M 2 AC box to PBC MU

    1.18CABLE/POWER CABLE, SHIELDED, 2X6 MM TFK421324/100M M 148

    1.19 Battery Cable, Halogenfree, 2 x 16mm2, 600V, 90C, UL, 50m Coil TFL90117/4 M 0

    2. Power Back-up System 2.1 CABINET/PBC-MU2 BMK90541/2 U 12.2 BATTERY CABINET/PBC-BU2 BMK90542/2 U 12.3 MOUNTING SET/PBC-02, PBC-BU SINGLE MOUNT NTM1010587/1 U 12.4 MOUNTING SET/POLE BRACKET SET NTM19208/3 Box 12.5 Kit Bolt and fisher for PBC-MU U 02.6 Kit Bolt and fisher for PBC-BU U 02.7 ADDITIONAL PARTS SET/PBC-02, ADD. PARTS NTM1010584/1 Set 02.8 BATTERY/ 24/BKC8610013/004 Kit 3

    3. Outdoor Installation Materials3.1 CABLE WITH CONNECTOR/RBS JUMPER N(M)-7/1 4m RPM1190245/4 U 123.2 Jumper Cable, 1/2", 3m, 7/16 Male to 7/16 Male, Indoor/Outdoor TSR95170/3 U 63.3 JUMPER CABLE/1/2",7/16-7/16 MALE,2M TSR95170/2 U 03.4 COMBINER UNIT/EXTERNAL HYBRID COMBINING KRF90154/1 U 03.5 EHCU (External Hybrid Combiner Unit), 824-960 MHz KRF20189/1 U 33.6 Installation Kit/Common Installation MAT 7/NTM201201 Sachet 13.7 CLAMP KIT, 7.6 MM NTM203058/11 Box 03.8 SET OF MATERIALS/TUBE KIT 8,5M NTM2013727/1 Set 7 01 Tube for 02 oils and 02 DC cable3.9 SET OF MATERIALS/SUPPORT KIT FOR TOWER/M NTM2013728/1 Set 13.10 SET OF MATERIALS/OVERLENGTH BOX FOR 30M NTM2013729/1 Set 63.11 MARKING SET/MAIN-REMOTE GSM NTM2013767/2 Set 23.12 Cable clamp kit, radio cable 10 mm, 2 clamps 6/NTM201230/42 Box 03.13 METALIC CABLE TIES STAINLESS STEEL STRAP L = 679MM SET12506/1 U 03.14 COATED CABLE TIE AE 314 SET145095/457 U 03.15 CABLE TIE 104*2,5 WHITE T18RDIN104X2,5MM U 03.16 CABLE TIE 140*2,5MM WHITE 100/PACK OHM43103 U 03.17 CABLE TIE WHITE 280*4,8MM 100/PACK CABLE TIE WHITE 280*4,8MM U 03.18 CABLE TIE 148X3,5MM BLACK T308DIN148X3,5MM U 03.19 CABLE TIE 388*7,8 CABLE TIE 388*7,8 U 03.20 Circuit Breaker 10A U 03.21 Circuit Breaker 6A U 03.22 Feeder marking label set Set 03.23 Sealing set set 63.24 Flexible tubing 25mm (m) M 03.25 E1 cable two paires (m) M See TRM3.26 CABLE WITH CONNECTOR/4E1,USER I/O,120OHM RPMR10206/2 U See TRM

    B 2

    010-

    06-2

    9

    DC cable To MU,RRU,PBC 5+(12+12+12+12+45+45)+5

  • 4. Antenna System4.1 KRE1012006/1 U 04.2 XXpol A-Panel 824 - 960Mhz/1710-2180Mhz (742266) 1/KRE 101 1917/1 U 34.3 Xpol A-Panel 824 - 960Mhz (739686) 1/KRE 101 1973/1 U 04.4 Xpol A-Panel 870 - 960Mhz (739630) 1/KRE 101 1799/1 U 04.5 Single Antenna, X-Pol, 806-960 MHz, 65 deg, 17,5 dBi, MET0-10(80010306) 1/KRE1012057/1 U 04.6 Down Tilt SXA120203/5 U 04.7 Kathrein 737 971 Downtilt kit for A- and Europanels, 0-8 degree SXA120103/5 U 04.8 A-PANNEL/F-PANNEL MOUNTING HARDWARE DOWNTILT KATHREIN 85010007 U 3

    5. Local Installation Materials5.1 Y/G 35MM Y/G 35MM M 36 GSM,RRU,MU,02PBC,03EHCU5.2 LUG35/10 LUG 35/10 U 32 GSM,RRU,MU,02PBC,03EHCU5.3 GROUNDING MATERIAL/CABLE KIT 1M/35MM2 YL 5/NTM201201/3 U 05.4 GROUNDING MATERIAL/CABLE KIT 2M/35MM2 YL 5/NTM201201/4 Kit 05.5 Grounding Material, Ground Bar Kit, Outdoor NTM2013326/1 Kit 0

    XXXpol A-Panel 806 - 960Mhz/1710-2180/1710-2180Mhz (80010292)

  • PLAN SPECIFICATION (TRM)Prepared (also subject responsible if other) `BMG/OIS/S Serge Randriamanana 2/127 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. FileBMG/OIS/S Haja Paul Ravaloniaina 2011-06-01 A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    ITEM Product Name Product Code Unit Request Note

    Near Site: ANM058AMM Type: AMM2p B NewConfig: 1+0Radio System: 15 GHz 2x2 HP

    1. Antenna System1.1 7 GHz Antenna

    1.1.1 0.6M 7GHz Antenna Module UKY 210 95/SC11 U 01.1.2 1.2M 7GHz Antenna Module UKY21040/SC11 U 01.1.3 1,8M 7GHz Antenna Module UKY 210 50/SC11D U 01.1.4 2.4M 7GHz Antenna Module UKY22001/SC12 U 0

    1.2 15 GHz Antenna1.2.1 0.3M 15GHz Antenna Module UKY 210 71/SC15 U 01.2.2 0.6M 15GHz Antenna Module UKY 210 76/SC15 U 11.2.3 1.2M 15GHz Antenna Module UKY 210 42/SC15 U 01.2.4 1.8M 15GHz Antenna Module UKY 210 52/SC15 U 0

    2. Radio System2.1 Radio Units 7GHz

    2.1.1 RADIO UNIT/RAU1 7/41 HP KIT NTM203080/41HP U 02.1.2 RADIO UNIT/RAU1 7/45 HP KIT NTM203080/45HP U 02.1.3 RADIO UNIT/RAU1 N 7/41 KIT NTM203078/41 U 02.1.4 RADIO UNIT/RAU1 N 7/45 KIT NTM203078/45 U 02.1.5 RADIO UNIT/RAU2 XU 7/41 KIT NTM203182/41 U 02.1.6 RADIO UNIT/RAU2 XU 7/45 KIT NTM203182/45 U 0

    2.2 Radio Units 15 GHz2.2.1 RADIO UNIT / RAU2 15/21 NTM203002/21HP U 02.2.2 RADIO UNIT / RAU2 15/25 NTM203002/25HP U 02.2.3 RADIO UNIT/RAU2 N 15/21 KIT NTM203069/21 U 02.2.4 RADIO UNIT/RAU2 N 15/25 KIT NTM203069/25 U 02.2.5 RAU2 Xu 15/21 Kit NTM203186/21 U 02.2.6 RAU2 Xu 15/25 Kit NTM203186/25 U 12.2.7 RADIO UNIT/RAU2 X 15/21 KIT NTM203159/21 U 02.2.8 RADIO UNIT/RAU2 X 15/25 KIT NTM203159/25 U 0

    3. Outdoor Units 3.1

    3.1.1 Power Splitter UPA 101 005/1 U 03.1.2 POWER DIVIDER/INT POWER SPLIT 15 GHZ ASY UPA10131/1 U 03.1.3 INTERNAL POWER SPLITTER 7/8 GHZ UPA90105/1 U 03.1.4 POWER DIVIDER/IPS2 7/8 ASYM UPA90114/1 U 03.1.5 External Power Splitter U 03.1.6 Wave guide U 0

    3.2 RF Cable3.2.1 10mm Radio Cable TZC 500 32/100 M 03.2.2 TZC 500 97, 25M 7.6mm NTM203056/25 M 203.2.3 TZC 500 97, 50M 7.6mm NTM203056/50 M 03.2.4 TZC 500 97, 75M 7.6mm NTM203056/75 M 03.2.5 TZC 500 97, 500M 7.6mm NTM203056/500 M 0

    3.3 Clamp Kit3.3.1 10mm Clamp Kit Radio Cable 6/NTM 201 230/42 Set 03.3.2 CLAMP KIT, 7.6 MM NTM203058/11 Set 1

    3.4 Earthing Kit3.4.1 Earthing Kit Radio Cable 10mm NGT 211 04/7 U 03.4.2 Earthing Kit, Radio Cable 7.6mm NGT21104/6 U 2

    3.5 RF Cable Connector3.5.1 CABLE WITH CONNECTOR/STATION RADIO CABLE RPM5176906/01 Set 03.5.2 CONTACT SET/N-MALE 7,6 MM CABLE SXK111511/6 Set 03.5.3 CONTACT SET/TNC-MALE 7,6 MM CABLE SXK111511/36 Set 13.5.4 CONTACT SET/TNC-MALE 10 MM CABLE SXK111511/36 Set 0

    Power Splitter

    B 2

    010-

    06-2

    9

  • PLAN SPECIFICATION (TRM)Prepared (also subject responsible if other) `BMG/OIS/S Serge Randriamanana 2/127 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. FileBMG/OIS/S Haja Paul Ravaloniaina 2011-06-01 A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    B 2

    010-

    06-2

    9

    4. Indoor Unit 4.1 Access Module Magazine 2p

    4.1.1 SET OF MATERIALS/AMM 2P KIT with DC connector NTM1010292/1 Set 04.1.2 NPU2 ROJR 211 002/1 U 04.1.3 FAU - 4 Kit BFB 102 103/1 U 0

    4.2 Access Module Magazine 2p B4.2.1 SET OF MATERIALS/AMM 2P B NPU3 R3 KIT with 2 DC connectors NTM 101 0292/6 Set 14.2.2 FAU - 4 Kit BFB 102 103/1 U 04.2.3 CABLE WITH CONNECTOR/DC,2X2,5MM2,5M RPM517560/5000 U 1

    4.3 Access Module Magazine 6p4.3.1 AMM 6-P NTM 101 0158/3 Set 04.3.2 NPU1B ROJR208006/1 U 04.3.3 PFU -3 Kit NTM 101 0653/1 U 0

    4.4 Access Module Magazine 6p C4.4.1 SET OF MATERIALS/AMM 6P C NPU3 R3 KIT NTM1010158/8 Set 04.4.2 SET OF MATERIALS/PFU3 B KIT NTM1010653/2 U 04.4.3 CABLE SET/TFL 424 03, 5M NTM20380/5 M 0

    4.5 Access Module Magazine 20p 4.5.1 AMM 20P -10 kit NTM 101 0154/1 Set 04.5.2 NPU1B ROJR208006/1 U 04.5.3 FAU - 1 Kit NTM 101 728/1 U 04.5.4 Air Guide Plate SEA 910 24/1 U 04.5.5 PFU - 1 Kit NTM 101 727/1 U 04.5.6 Fan Alarm Cable 0.6M RPMR 102 02/1 U 04.5.7 CABLE SET/TFL 424 03, 5M NTM20380/5 M 04.5.8 Cable Shelf U 0

    4.6 Access Module Magazine 20p B4.6.1 SET OF MATERIALS/AMM 20P B-10 R3 KIT NTM1010154/4 Set 04.6.2 SET OF MATERIALS/FAU1 KIT NTM101728/1 Set 04.6.3 PFU - 1 Kit NTM 101 727/1 U 04.6.4 Air Guide Plate SEA 910 24/1 U 04.6.5 CABLE SET/TFL 424 03, 5M NTM20380/5 M 04.6.6 Cable Shelf U 0

    4.7 E1 Cable and Krone Block4.7.1 Krone Block U 14.7.2 E1 cable two paires (m) M 104.7.3 Hinged Label Holder U 14.7.4 CABLE WITH CONNECTOR/4E1,USER I/O,120OHM RPMR10206/2 U 1

    4.8 Modem Unit4.8.1 MODEM UNIT/MMU2 B KIT ROJ 208 1301/10 U 04.8.2 MODEM UNIT/MMU2 C KIT NTM203126/1 U 14.8.3 MMU2 B4 Kit NTM 203 007/1 U 04.8.4 MMU2 B4 - 8 Kit NTM 203 013/1 U 04.8.5 MMU2 B4 - 16Kit NTM 203 014/1 U 04.8.6 MMU2 B4 - 34 Kit NTM 203 015/1 U 04.8.7 MMU2 C4 - 34 Kit NTM 203 028/1 U 04.8.8 MMU2 C4 - 64 Kit NTM 203 029/1 U 0

    4.9 LTU4.9.1 LTU 3 12/1 ROJR211005/1 U 04.9.2 LTU 16/ 1 ROJ 208 003/1 U 04.9.3 LTU 16 x 2 ROJ 208 002 U 04.9.4 PLUG-IN UNIT/LTU 16/1 ROJR208002/3 U 0`4.10 Dummy Unit

    4.10.1 DUMMY UNIT/DUMMY UNIT 230 MM,LONG 033/BFY1130431/W U 14.10.2 DUMMY UNIT/DUMMY UNIT 115 MM, SHORT SXK1115134/1 U 1

    4.11 DDU and DC/DC Converter4.11.1 DDU NTM 203 43/1 U 04.11.2 Cable : BFU to DDU RPM 919 479/15 U 04.11.3 Cable : DDU to NPU2 TFL 424 02 0610 U 04.11.4 DC/DC Converter BMR 911 20/1 U 04.11.5 Power Cable : BFU to DC/DC Converter RPM 113 7109/1 U 04.11.6 Connection Cable : DC/DC Converter to DDU RPM 919 480/15 U 04.11.7 Cable : DDU to PFU-3 or PFU-1 TFL 424 02 0610 U 04.11.8 CABLE SET/TFL 424 03,5M NTM20380/5 U 0

  • PLAN SPECIFICATION (TRM)Prepared (also subject responsible if other) `BMG/OIS/S Serge Randriamanana 2/127 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. FileBMG/OIS/S Haja Paul Ravaloniaina 2011-06-01 A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    B 2

    010-

    06-2

    9

    5. Rack Transmission 5.1 TMR 9301 Outdoor NTM 101 1340/1 U 05.2 TMR 9302 without AC/DC Converter SDC90132/1 U 1 Pole mounting5.3 16U Transmission rack 19" Rack U 05.4 Rack Frame 19'' Rack Kit 16U, Wall, H=71 NTM 2013605/1 U 05.5 21U Transmission rack 19" Rack U 05.6 47U Transmission rack 19" Rack U 0

    6. Grounding6.1 Y/G 35MM Y/G 35MM M 5 RAU,RACK6.2 LUG 35/10 LUG35/10 U 4 RAU,RACK6.3 GROUNDING MATERIAL/CABLE KIT 2M/35MM2 YL 5/NTM201201/4 Kit 06.4 Grounding Material, Ground Bar Kit, Outdoor NTM2013326/1 Kit 0

  • PLANT SPECIFICATION (TRM-FACING SITE)Prepared (also subject responsible if other) Document No.BMG/OIS/S Serge Randriamanana 3/127 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. FileBMG/OIS/S Haja Paul Ravaloniaina 2011-06-01 A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    ITEM Product Name Product Code Unit Request Note

    Facing Site: ANM036AMM Type: AMM20p ExistingConfig: 1+0Radio System: 15GHz 2x2 HP

    1. Antenna System1.1 7 GHz Antenna

    1.1.1 0.6M 7GHz Antenna Module UKY 210 95/SC11 U 01.1.2 1.2M 7GHz Antenna Module UKY21040/SC11 U 01.1.3 1,8M 7GHz Antenna Module UKY 210 50/SC11D U 01.1.4 2.4M 7GHz Antenna Module UKY22001/SC12 U 0

    1.2 15 GHz Antenna1.2.1 0.3M 15GHz Antenna Module UKY 210 71/SC15 U 01.2.2 0.6M 15GHz Antenna Module UKY 210 76/SC15 U 11.2.3 1.2M 15GHz Antenna Module UKY 210 42/SC15 U 01.2.4 1.8M 15GHz Antenna Module UKY 210 52/SC15 U 0

    2. Radio System2.1 Radio Units 7GHz

    2.1.1 RADIO UNIT/RAU1 7/41 HP KIT NTM203080/41HP U 02.1.2 RADIO UNIT/RAU1 7/45 HP KIT NTM203080/45HP U 02.1.3 RADIO UNIT/RAU1 N 7/41 KIT NTM203078/41 U 02.1.4 RADIO UNIT/RAU1 N 7/45 KIT NTM203078/45 U 02.1.5 RADIO UNIT/RAU2 XU 7/41 KIT NTM203182/41 U 02.1.6 RADIO UNIT/RAU2 XU 7/45 KIT NTM203182/45 U 0

    2.2 Radio Units 15 GHz2.2.1 RADIO UNIT / RAU2 15/21 NTM203002/21HP U 02.2.2 RADIO UNIT / RAU2 15/25 NTM203002/25HP U 02.2.3 RADIO UNIT/RAU2 N 15/21 KIT NTM203069/21 U 02.2.4 RADIO UNIT/RAU2 N 15/25 KIT NTM203069/25 U 02.2.5 RAU2 Xu 15/21 Kit NTM203186/21 U 12.2.6 RAU2 Xu 15/25 Kit NTM203186/25 U 02.2.7 RADIO UNIT/RAU2 X 15/21 KIT NTM203159/21 U 02.2.8 RADIO UNIT/RAU2 X 15/25 KIT NTM203159/25 U 0

    3. Outdoor Units 3.1

    3.1.1 Power Splitter UPA 101 005/1 U 03.1.2 POWER DIVIDER/INT POWER SPLIT 15 GHZ ASY UPA10131/1 U 03.1.3 INTERNAL POWER SPLITTER 7/8 GHZ UPA90105/1 U 03.1.4 POWER DIVIDER/IPS2 7/8 ASYM UPA90114/1 U 03.1.5 External Power Splitter U 03.1.6 Wave guide U 0

    3.2 RF Cable3.2.1 10mm Radio Cable TZC 500 32/100 M 03.2.2 TZC 500 97, 25M 7.6mm NTM203056/25 M 03.2.3 TZC 500 97, 50M 7.6mm NTM203056/50 M 453.2.4 TZC 500 97, 75M 7.6mm NTM203056/75 M 03.2.5 TZC 500 97, 500M 7.6mm NTM203056/500 M 0

    3.3 Clamp Kit3.3.1 10mm Clamp Kit Radio Cable 6/NTM 201 230/42 Set 03.3.2 CLAMP KIT, 7.6 MM NTM203058/11 Set 2

    3.4 Earthing Kit3.4.1 Earthing Kit Radio Cable 10mm NGT 211 04/7 U 03.4.2 Earthing Kit, Radio Cable 7.6mm NGT21104/6 U 2

    3.5 RF Cable Connector3.5.1 CABLE WITH CONNECTOR/STATION RADIO CABLE RPM5176906/01 Set 03.5.2 CONTACT SET/N-MALE 7,6 MM CABLE SXK111511/6 Set 03.5.3 CONTACT SET/TNC-MALE 7,6 MM CABLE SXK111511/36 Set 13.5.4 CONTACT SET/TNC-MALE 10 MM CABLE SXK111511/36 Set 0

    Power Splitter

    B 2

    010-

    06-2

    9

  • PLANT SPECIFICATION (TRM-FACING SITE)Prepared (also subject responsible if other) Document No.BMG/OIS/S Serge Randriamanana 3/127 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. FileBMG/OIS/S Haja Paul Ravaloniaina 2011-06-01 A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    B 2

    010-

    06-2

    9

    4. Indoor Unit 4.1 Access Module Magazine 2p

    4.1.1 SET OF MATERIALS/AMM 2P KIT NTM1010292/1 Set 04.1.2 NPU2 ROJR 211 002/1 U 04.1.3 FAU - 4 Kit BFB 102 103/1 U 0

    4.2 Access Module Magazine 2p B4.2.1 SET OF MATERIALS/AMM 2P B NPU3 R3 KIT NTM 101 0292/6 Set 04.2.2 FAU - 4 Kit BFB 102 103/1 U 04.2.3 CABLE WITH CONNECTOR/DC,2X2,5MM2,5M RPM517560/5000 U 0

    4.3 Access Module Magazine 6p4.3.1 AMM 6-P NTM 101 0158/3 Set 04.3.2 NPU1B ROJR208006/1 U 04.3.3 PFU -3 Kit NTM 101 0653/1 U 0

    4.4 Access Module Magazine 6p C4.4.1 SET OF MATERIALS/AMM 6P C NPU3 R3 KIT NTM1010158/8 Set 04.4.2 SET OF MATERIALS/PFU3 B KIT NTM1010653/2 U 04.4.3 CABLE SET/TFL 424 03, 5M NTM20380/5 M 0

    4.5 Access Module Magazine 20p 4.5.1 AMM 20P -10 kit NTM 101 0154/1 Set 04.5.2 NPU1B ROJR208006/1 U 04.5.3 FAU - 1 Kit NTM 101 728/1 U 04.5.4 Air Guide Plate SEA 910 24/1 U 04.5.5 PFU - 1 Kit NTM 101 727/1 U 04.5.6 Fan Alarm Cable 0.6M RPMR 102 02/1 U 04.5.7 CABLE SET/TFL 424 03, 5M NTM20380/5 M 04.5.8 Cable Shelf U 0

    4.6 Access Module Magazine 20p B4.6.1 SET OF MATERIALS/AMM 20P B-10 R3 KIT NTM1010154/4 Set 04.6.2 SET OF MATERIALS/FAU1 KIT NTM101728/1 Set 04.6.3 PFU - 1 Kit NTM 101 727/1 U 04.6.4 Air Guide Plate SEA 910 24/1 U 04.6.5 CABLE SET/TFL 424 03, 5M NTM20380/5 M 04.6.6 Cable Shelf U 0

    4.7 E1 Cable and Krone Block4.7.1 Krone Block U 0

    4.7.2 E1 cable two paires (m) M 0 TELMA provide from DDF FO to DDF ML4.7.3 Hinged Label Holder U 14.7.4 CABLE WITH CONNECTOR/4E1,USER I/O,120OHM RPMR10206/2 U 0

    4.8 Modem Unit4.8.1 MODEM UNIT/MMU2 B KIT ROJ 208 1301/10 U 04.8.2 MODEM UNIT/MMU2 C KIT NTM203126/1 U 14.8.3 MMU2 B4 Kit NTM 203 007/1 U 04.8.4 MMU2 B4 - 8 Kit NTM 203 013/1 U 04.8.5 MMU2 B4 - 16Kit NTM 203 014/1 U 04.8.6 MMU2 B4 - 34 Kit NTM 203 015/1 U 04.8.7 MMU2 C4 - 34 Kit NTM 203 028/1 U 04.8.8 MMU2 C4 - 64 Kit NTM 203 029/1 U 0

    4.9 LTU4.9.1 LTU 3 12/1 ROJR211005/1 U 04.9.1 LTU 16/ 1 ROJ 208 003/1 U 04.9.2 LTU 16 x 2 ROJ 208 002 U 04.9.3 PLUG-IN UNIT/LTU 16/1 ROJR208002/3 U 0`4.10 Dummy Unit

    4.10.1 DUMMY UNIT/DUMMY UNIT 230 MM,LONG 033/BFY1130431/W U 14.10.2 DUMMY UNIT/DUMMY UNIT 115 MM, SHORT SXK1115134/1 U 1

    4.11 DDU and DC/DC Converter4.11.1 DDU NTM 203 43/1 U 04.11.2 Cable : BFU to DDU RPM 919 479/15 U 04.11.3 Cable : DDU to NPU2 TFL 424 02 0610 U 04.11.4 DC/DC Converter BMR 911 20/1 U 04.11.5 Power Cable : BFU to DC/DC Converter RPM 113 7109/1 U 04.11.6 Connection Cable : DC/DC Converter to DDU RPM 919 480/15 U 04.11.7 Cable : DDU to PFU-3 or PFU-1 TFL 424 02 0610 U 04.11.8 CABLE SET/TFL 424 03,5M NTM20380/5 U 0

  • PLANT SPECIFICATION (TRM-FACING SITE)Prepared (also subject responsible if other) Document No.BMG/OIS/S Serge Randriamanana 3/127 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. FileBMG/OIS/S Haja Paul Ravaloniaina 2011-06-01 A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    B 2

    010-

    06-2

    9

    5. Rack Transmission 5.1 TMR 9301 Outdoor NTM 101 1340/1 U 05.2 TMR 9302 without AC/DC Converter SDC90132/1 U 05.3 16U Transmission rack 19" Rack U 05.4 Rack Frame 19'' Rack Kit 16U, Wall, H=71 NTM 2013605/1 U 05.5 21U Transmission rack 19" Rack U 05.6 47U Transmission rack 19" Rack U 0

    6. Grounding6.1 Y/G 35MM Y/G 35MM M 10 RAU6.2 LUG 35/10 LUG35/10 U 2 RAU6.3 GROUNDING MATERIAL/CABLE KIT 2M/35MM2 YL 5/NTM201201/4 Kit 06.4 Grounding Material, Ground Bar Kit, Outdoor NTM2013326/1 Kit 0

  • DENOMINATION PRODUCT / NO QTY

    EQUIPPED CABINET/RBS 2111 MU-12 BFE899101/2 2

    EQUIPPED CABINET/RBS 2111 RRU-N RRUN9P-22 / KRC 161 170/1 6

    EHCU - ANTENNA CONNECTORS 3

    CONNECTION CABLE/OPTICAL FIBER (100M) TSR 899 088/2 6

    CABLE WITH CONNECTOR/RBS JUMPER N(M)-7/1 RPM 11902 45/4 12

    CABLE WITH CONNECTOR/RBS JUMPER TSR 951 70/3 6

    CABLE/TFL 301 6003/4 10M SPO / ALARM CABLE TPM 101 0023/10M 2

    TG SYNC CABLE RBS 2111 - RBS 2111 RPM 1190408/05500 1

    MATERIAL REQUESTED PER CONFIGURATION

    RBS 2111 V2 CABINET WITH S4/4/4 / 900MHZ CONFIGURATION

  • ALLOCATION TABLEPrepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 4/193 19-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    AC System faultPBC-02 System fault

    Alarm Class

    0102

    Contact functionAlarm Designation

    A 20

    09-1

    1-26

    2011-06-01

    Alarm Inlet Cable marking

    ALLOCATION TABLE : ALARM

    Part No/Colour

  • TEST PROTOCOL (RBS)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 83-IPA 143 5546 UenDoc respons/Approved Checked Test R Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    TEST RECORD - COMMISSIONING AND INTEGRATION

    Site Name : Anosizato

    Site ID: ANM058 Region:

    Testing Date : Type of RBS: GSM 900

    Ericsson Tester Name Telma Mobile Representative

    1.0 STATUS CHECK

    1.1 CELL CONFIGURATION

    Cell Configuration : + +

    Cell Orientation Cell 1 Cell 2 Cell 3

    1.2 INSTALLATION CHECK

    O.K Remarks :

    1.3 TEST CHECK LIST

    Sites installation tests: O.K Fail Remarks

    - System voltage

    - Start-up of RBS

    - Self test

    - PSU test

    - PSU OMT power AC mains alarm

    - Internal Alarm Test

    - Read IDB

    - External alarm test

    - Battery backup test

    B 2

    010-

    06-2

    9

    Analamanga

    2011-06-01

    2111V2

  • TEST PROTOCOL (RBS)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 83-IPA 143 5546 UenDoc respons/Approved Checked Test R Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900B 201

    0-06

    -29

    2011-06-01

    1.4 Software / Database

    1.4.1 RAM File Package

    1.4.2 FLASH File Package

    1.4.3 FLASH File Package (BACK-UP)

    1.4.4 IDB Configuration File :

    1.5 Voltage Test

    1.5.1 Incoming A/C1-Phase 2-Phase 3-Phase

    1.5.2 DC VoltagePBC-02 PBC-BU

    1.5.3 DC VoltageMU1 MU2

    1.5.4 Ground to Neutral Volt

    1.5.5 Battery VoltagePBC-02 PBC-BU

    2.0

    2.1 2Mbit loop back TestLoop TX and RX incoming E1's at DF and confirm with BSC that the E1 is okE1 No.1 Pass Fail2 Pass Fail

    2.2 Activation of TRU (BSC)Main Unit 1 (MASTER/EXT CABINET)

    RRU-N1 RRU-N2 RRU-N3

    RRU-N4 RRU-N5 RRU-N6

    INTEGRATION TEST

  • TEST PROTOCOL (RBS)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 83-IPA 143 5546 UenDoc respons/Approved Checked Test R Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900B 201

    0-06

    -29

    2011-06-01

    2.3 Internal Alarm Test OK Fail

    2.3.1 Hardware Alarm2.3.2 Opto Fibre Cable2.3.3 Internal Power Capacity Reduced

    Test CallsTRU ARFCH BSIC Rx Lev TS0 TS1 TS2 TS3 TS4 TS5 TS6 TS7

    123456789101112

    2.5 PSTN TO MS CALLPass Fail

    2.6 HANDOVER TESTA to B A to C B to A B to C C to A C to B

    2.7 GPRS/WAP TEST

    Pass Fail Remarks2.7.1 Ping Telma Server

    2.8 EXTERNAL ALARM TEST (E2E where possible)

    Pass Fail RemarksPBC Fault

    2.9 CONCLUDING ROUTINES

    1 Update and save the IDB

    2 Checklist before ending test

    Cell ID

    2.4 INTEGRATION TEST

  • TEST PROTOCOL (RBS)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 83-IPA 143 5546 UenDoc respons/Approved Checked Test R Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900B 201

    0-06

    -29

    2011-06-01

    3.0 REMARKS

    3.1 Remarks within Ericsson's Responsibility ;

    3.2 Remarks outside Ericsson's Responsibility ;

    Ericsson Representative Telma Mobile Representative

    Date : Date :

  • TEST PROTOCOL (TRM)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 2/153 83-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A

    Project: Phase 1DSite name: Anosizato ANM058 Facing ANM036

    Site name / ID NE Name / ID

    Ethernet IP Address: Subnet Mask

    Network Element

    Parameter

    DC Supply

    OKNE Setup Parameters

    Pass FailTraffic Cable TestTraffic Routing TestFan Alarm TestUser InUser Out1+1 E1 SNCP TestDCN and Site LAN Test

    Radio Terminal

    OKHop Setup Parameters

    ParameterTransmitter output powerCalculated received level dBmRF input level (near-end 1/ far-end 2)* / /Interference test* The received level must be within +/- 3 dB from the calculated level.

    8

    14 dBm

    Test no: Parameter

    Ra 2 (1+1 config.only)

    Test no: Ra 1

    dBm11

    13 dBm

    5

    7

    10

    Unit

    9

    12

    Test no:2

    Test no:34

    Parameter

    6

    Parameter

    PFU1/PFU3 (Redundant DC)

    V V

    Test no:

    1

    PFU1/PFU2/ PFU3/PFU4

    2011-06-01

    MINI-LINK TN Traffic Node Functional Test

    SID_ANM058_900B 201

    0-06

    -29

  • TEST PROTOCOL (TRM)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 2/153 83-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A

    Project: Phase 1D

    2011-06-01 SID_ANM058_900B 201

    0-06

    -29

    ParameterNear alarm checkSwitch test (for 1+1 configuration only)

    ParameterPerformance test (By MSM)

    OKStorage of Configuration File

    Remarks:

    Ericsson Representative Telma Mobile Representative

    Date : Date :

    Pass Fail17

    Parameter

    Test no:

    Test no: Fail1516

    Pass

    18Test no:

  • PRODUCT LIST (RBS)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/193 32-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1D

    Site: Anosizato ANM058 Type of RBS GSM

    Supervisor name: Date:

    SERIAL MANF.POS UNIT PART NUMBER REV NUMBER DATE

    RBS

    Main Unit 1 BFE899101/2

    Main Unit 2 BFE899101/2

    RRU-N 9P 22 (900Mhz) KRC161170/1

    RRU-N 9P 22 (900Mhz) KRC161170/1

    RRU-N 9P 22 (900Mhz) KRC161170/1

    RRU-N 9P 22 (900Mhz) KRC161170/1

    RRU-N 9P 22 (900Mhz) KRC161170/1

    RRU-N 9P 22 (900Mhz) KRC161170/1

    PBC-02 BMK 90541/2

    PBC-BU BMK 90542/2

    ANTENNA SYSTEMS

    Cell A Kathrein

    Cell B Kathrein

    Cell C Kathrein

    B 20

    10-0

    6-29

    2011-06-01

    9002111 V2

  • PRODUCT LIST (TRM)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 2/193 32-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058 Facing ANM036

    Supervisor name: Date:

    Near Site: ANM058POS in MANUFAC

    UNIT PRODUCT NUMBER REV SERIAL NUMBER Cabinet DATE

    1-ANTENNA18GHz, 0.6m HP18GHz, 1.2m HP15GHz, 0.3m HP15GHz, 0.6m HP15GHz, 1.2m HP15GHz, 1.8m HP13GHz, 0.6m HP13GHz, 1.2m HP13GHz, 1.8m HP7/8GHz, 0.6m HP7/8GHz, 1.2m HP UKY21040/SC117/8GHz, 1.8m HP 'UKY 210 50/SC11D7/8GHz, 2.4m HP2-RADIO EQUIPMENTRAU2 18/12 HP Kit NTM 203 59/12HPRAU2 18/16 HP Kit NTM 203 59/16HPRAU2 N 15/23 NTM 203002/23RAU2 N 15/27 NTM 203002/27RAU2 15/24 HP Kit NTM 203002/24HPRAU2 15/28 HP Kit NTM 203002/28HPRAU 13-E/13 HP RA 131 1113/00RAU 13-E/17 HP RA 131 1117/00RAU2 N 13/13 NTM 203025/13RAU2 N 13/17 NTM 203025/17RAU1 N 7/31 NTM 203023/31RAU1 N 7/35 NTM 203023/35RAU N 8/43 RA 080 1143/00RAU N 8/47 RA 080 1147/00RADIO UNIT/RAU1 7/41 HP KIT NTM203080/41HPRADIO UNIT/RAU1 7/45 HP KIT NTM203080/45HPRADIO UNIT/RAU1 N 7/41 KIT NTM203078/41RADIO UNIT/RAU1 N 7/45 KIT NTM203078/45RADIO UNIT / RAU2 15/21 NTM203002/21HPRADIO UNIT / RAU2 15/25 NTM203002/25HPRADIO UNIT/RAU2 N 15/21 KIT NTM203069/21RADIO UNIT/RAU2 N 15/25 KIT NTM203069/25RAU2 Xu 15/21 Kit NTM203186/21RAU2 Xu 15/25 Kit NTM203186/25RADIO UNIT/RAU2 X 15/21 KIT NTM203159/21RADIO UNIT/RAU2 X 15/25 KIT NTM203159/25

    3-Traffic Node3-1 AMMAMM2p Kit NTM1010292/1AMM 2P-B Kit NTM1010292/6AMM 6P NTM 101 0158/3AMM 6P-B Kit NTM 101 0158/3AMM 6P-C Kit NTM1010158/8AMM 20P-10 Kit NTM101 0154/1AMM 20P-B Kit NTM1010154/4

    UKY 210 41/SC15DUKY 210 51/SC15DUKY 210 95/SC11

    UKY22001/SC12

    UKY 21043/SC15D

    UKY 210 76/SC15UKY 210 71/SC15

    B 2

    010-

    06-2

    9

    2011-06-01

    UKY 21077/SC15

    UKY 210 42/SC15

    UKY 210 89/SC15UKY 210 52/SC15

  • PRODUCT LIST (TRM)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 2/193 32-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1D

    B 2

    010-

    06-2

    9

    2011-06-01

    3-2 NPUNPU 2 ROJR211 002/1NPU3 ROJR211011/1NPU3B ROJR211004/1NPU1B ROJR208006/13-3 PFUPFU1 Kit NTM 101 727/1PFU3 Kit ROJR219012/1PFU3 B Kit NTM1010653/23-4 MMUMODEM UNIT/MMU2 B KIT ROJ 208 1301/10MODEM UNIT/MMU2 C KIT NTM203126/1MMU2 B 4 ROJ 208 1301/4MMU2 B4 - 8 Kit NTM 203 013/1MMU2 B 4-16 Kit NTM 203 014/1MMU2 C 4-34 Kit NTM 203 028/1MMU2 C 4-64 Kit NTM 203 029/13-5 FAUFAU1 Kit NTM 101 728/1FAU2 ROJR219011/1FAU4 BFB102103/13-6 DummyDummy Unit 230mm 033/BFY1130431/WDummy Unit 115mm SXK1115134/13-7 LTULTU 3 12/1 ROJR211005/1LTU 155 E/O ROJR 208 003/1LTU 16/1 ROJ 208 003/1LTU 16 x 2 ROJ 208 002PLUG-IN UNIT/LTU 16/1 ROJR208002/3

  • PRODUCT LIST (TRM-FACING SITE)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 3/193 32-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1DSite: Anosizato ANM058

    Supervisor name: Date:

    Far end site: ANM036 POS in MANUFACUNIT PRODUCT NUMBER REV SERIAL NUMBER Cabinet DATE

    1-ANTENNA18GHz, 0.6m HP18GHz, 1.2m HP15GHz, 0.3m HP15GHz, 0.6m HP13GHz, 1.2m HP13GHz, 1.8m HP7/8GHz, 0.6m HP7/8GHz, 1.2m HP UKY21040/SC117/8GHz, 1.8m HP 'UKY 210 50/SC11D7/8GHz, 2.4m HP

    2-RADIO EQUIPMENTRAU2 18/12 HP Kit NTM 203 59/12HPRAU2 18/16 HP Kit NTM 203 59/16HPRAU2 N 15/23 NTM 203002/23RAU2 N 15/27 NTM 203002/27RAU2 15/24 HP Kit NTM 203002/24HPRAU2 15/28 HP Kit NTM 203002/28HPRAU 13-E/13 HP RA 131 1113/00RAU 13-E/17 HP RA 131 1117/00RAU2 N 13/13 NTM 203025/13RAU2 N 13/17 NTM 203025/17RAU1 N 7/31 NTM 203023/31RAU1 N 7/35 NTM 203023/35RAU N 8/43 RA 080 1143/00RAU N 8/47 RA 080 1147/00RADIO UNIT/RAU1 7/41 HP KIT NTM203080/41HPRADIO UNIT/RAU1 7/45 HP KIT NTM203080/45HPRADIO UNIT/RAU1 N 7/41 KIT NTM203078/41RADIO UNIT/RAU1 N 7/45 KIT NTM203078/45RADIO UNIT / RAU2 15/21 NTM203002/21HPRADIO UNIT / RAU2 15/25 NTM203002/25HPRADIO UNIT/RAU2 N 15/21 KIT NTM203069/21RADIO UNIT/RAU2 N 15/25 KIT NTM203069/25RAU2 Xu 15/21 Kit NTM203186/21RAU2 Xu 15/25 Kit NTM203186/25RADIO UNIT/RAU2 X 15/21 KIT NTM203159/21RADIO UNIT/RAU2 X 15/25 KIT NTM203159/25

    3-Traffic Node3-1 AMMAMM2p Kit NTM1010292/1AMM 2P-B Kit NTM1010292/6AMM 6P NTM 101 0158/3AMM 6P-B Kit NTM 101 0158/3AMM 6P-C Kit NTM1010158/8AMM 20P-10 Kit NTM101 0154/1AMM 20P-B Kit NTM1010154/43-2 NPUNPU 2 ROJR211 002/1NPU3 ROJR211011/1NPU3B ROJR211004/1NPU1B ROJR208006/13-3 PFUPFU1 Kit NTM 101 727/1PFU3 Kit ROJR219012/1PFU3 B Kit NTM1010653/23-4 MMUMODEM UNIT/MMU2 B KIT ROJ 208 1301/10MODEM UNIT/MMU2 C KIT NTM203126/1MMU2 B 4 ROJ 208 1301/4MMU2 B4 - 8 Kit NTM 203 013/1MMU2 B 4-16 Kit NTM 203 014/1MMU2 C 4-34 Kit NTM 203 028/1MMU2 C 4-64 Kit NTM 203 029/1

    UKY 210 41/SC15D

    2011-06-01

    UKY 21077/SC15

    UKY 210 51/SC15DUKY 210 95/SC11

    B 2

    010-

    06-2

    9

    UKY22001/SC12

    UKY 210 71/SC15UKY 21043/SC15D

    UKY 210 76/SC15

  • PRODUCT LIST (TRM-FACING SITE)Prepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 3/193 32-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A SID_ANM058_900

    Project: Phase 1D

    2011-06-01B 201

    0-06

    -29

    3-5 FAUFAU1 Kit NTM 101 728/1FAU2 ROJR219011/1FAU4 BFB102103/13-6 DummyDummy Unit 230mm 033/BFY1130431/WDummy Unit 115mm SXK1115134/13-7 LTULTU 3 12/1 ROJR211005/1LTU 155 E/O ROJR 208 003/1LTU 16/1 ROJ 208 003/1LTU 16 x 2 ROJ 208 002PLUG-IN UNIT/LTU 16/1 ROJR208002/3

  • SITE INSPECTION LISTPrepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A

    Project: Phase 1DSite: Anosizato ANM058

    1 SITE DOCUMENTATION

    OK N/A NOK Remarks1.1 Site configuration

    1.2 Site tables/drawings

    1.3 Plant Specification

    1.4 Test records

    2 SITE ENVIRONMENT OK N/A NOK Remarks

    2.1 Lights on site

    2.2 Temperature on site

    2.3 Cleanliness on site

    2.4 Raised floor (if any)

    2.5 Cable lead-in mounted correctly

    2.6 Cabin condition

    3 MECHANICS OK N/A NOK Remarks

    3.1 Cable ladders and overhead mechanics

    3.2 Cable tray

    3.3 Visible damage on mechanics

    2011-06-01

    Mark the box with an "X" for OK if Correctly installed, "X" for NOK if not correctly installed, and N/A if Not applicable.

    SID_ANM058_900B 201

    0-06

    -29

  • SITE INSPECTION LISTPrepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A

    Project: Phase 1DSite: Anosizato ANM058

    2011-06-01 SID_ANM058_900B 201

    0-06

    -29

    4 GROUNDING AND LIGHTNING PROTECTIONS OK N/A NOK Remarks

    4.1 Grounding connected to main ground system

    4.2 Antenna feeder connected to ground

    4.3 Antenna grounding

    4.4 Microwave links grounding

    4.5 Crimping of C-clamps and cable lugs

    4.6 Grounding connection in AC supply box

    4.7 Grounding connection of equipment/cabinet

    5 RBS/ External hardware OK N/A NOK Remarks

    5.1 Cabinet/unit mounted

    5.2 All cables connected to the cabinet/unit

    5.3 Visible damage on the cabinet/unit

    5.4 Are the labels on external cables

    5.5 Power connection to the cabinet

    5.6 RF jumper cables properly installed and connected

    5.7 Unused RF ports should be covered

    6 DISTRIBUTION UNIT ODF/DDF OK N/A NOK Remarks

    6.1 Distribution unit mounted

    6.2 All cables connecting to the unit

    6.3 Check cable route

    6.4 Check labels on cables

  • SITE INSPECTION LISTPrepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A

    Project: Phase 1DSite: Anosizato ANM058

    2011-06-01 SID_ANM058_900B 201

    0-06

    -29

    7 POWER SUPPLY OK N/A NOK Remarks

    7.1 Circuit-breakers/fuses (AC/DC)

    7.2 Cable area and connections

    7.3 Cables in strain over sharp edges

    7.4 Batteries (check cell-installation and polarity)

    7.6 Mains power (AC voltage input range)

    7.7 DC distribution (DC voltage and polarity)

    8 ALARM UNIT / OK N/A NOK Remarks

    8.1 Alarm unit mounted

    8.2 All cables connected

    8.3 Allocation tables available

    9 ANTENNA EQUIPMENT OK N/A NOK Remarks

    9.1 Antennas correctly mounted

    9.2 Antenna support construction

    9.3 Antenna tilt Cell ACell BCell C

    9.4 Antenna Direction Cell ACell BCell C

    9.5 Antenna Type Cell ACell BCell C

    9.6 Site Height Antenna Height AGLCell ACell BCell C

    9.7 Any obstacles observed in front of antennas

    7.5 All cables/ bus bars/ circuit breakers correctly labeled

  • SITE INSPECTION LISTPrepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A

    Project: Phase 1DSite: Anosizato ANM058

    2011-06-01 SID_ANM058_900B 201

    0-06

    -29

    10 OUTDOOR CABLES OK N/A NOK Remarks

    10.1 Feeder (damage, bending radius and sealing)

    10.2 Feeder (fixing and clamping)

    10.3 Feeder protection on horizontal level

    10.4 Feeder cables should be labeled on 2 pointsClose to indoor and external jumpers)

    11 MINI-LINK OUTDOOR OK N/A NOK Remarks

    11.1 Antenna installed correctly

    11.2 Radio unit installed correctly

    12 MINI LINK INDOOR OK N/A NOK Remarks

    12.1 AMM/TN installed correctly

    12.2 Fan unit installed correctly

    12.3 SAU installed correctly

    12.4 MMU(s) installed correctly

    12.5 SMU installed correctly

    12.6 RF cable connected properly

    12.7 PCM cable connected properly

    12.8 All cables are labeled properly

  • SITE INSPECTION LISTPrepared (also subject responsible if other) Document No.

    BMG/OIS/S Serge Randriamanana 1/153 11-IPA 143 5546 UenDoc respons/Approved Checked Date Rev. File

    BMG/OIS/S Haja Paul Ravaloniaina A

    Project: Phase 1DSite: Anosizato ANM058

    2011-06-01 SID_ANM058_900B 201

    0-06

    -29

    13 SITE SAFETY AND GENERAL OK N/A NOK Remarks

    13.1 Hazardous voltage exposed

    13.2 Door easily opened

    13.3 Warning signs indicating hazardous activities

    13.4 Packing material removed from site

    13.5 Site clean and tidy

    Installation inspection performed by.

    Name : Date:

    Outstanding items list

    The outstanding item has to be completed before the site is ready for acceptance.

    Remark- Remarks and outstanding Item Sign and dateNumber when completed

    OUTSTANDING ITEMS CORRECTED

    Signature:

  • RBS 2111 4+4+4-900 MHz - with PBC- with AMM2p B.

    Pos. Cable type Pos. Pos. Cable type Pos.

    MU1- DC BOX -48V DC In

    DC BOX - MU1

    -48V DC Out

    2x10mm2

    DC Power cable

    DC BOX - MU1 -48V DC Out

    MU1- DC BOX

    -48V DC In

    MU2- DC BOX -48V DC In

    DC BOX - MU2

    -48V DC Out

    2x10mm2

    DC Power cable

    DC BOX - MU2 -48V DC Out

    MU2- DC BOX

    -48V DC In

    RRU A1 - DC BOX -48V DC

    DC BOX - RRU A1

    -48V DC

    2x10mm2

    DC Power cable

    RRU A1 - DC BOX -48V DC

    DC BOX - RRU A1

    -48V DC

    RRU A2 - DC BOX -48V DC

    DC BOX - RRU A2

    -48V DC

    2x10mm2

    DC Power cable

    RRU A2 - DC BOX -48V DC

    DC BOX - RRU A2

    -48V DC

    RRU B1 - DC BOX -48V DC

    DC BOX - RRU B1

    -48V DC

    2x10mm2

    DC Power cable

    RRU B1 - DC BOX -48V DC

    DC BOX - RRU B1

    -48V DC

    RRU B2 - DC BOX -48V DC

    DC BOX - RRU B2

    -48V DC

    2x10mm2

    DC Power cable

    RRU B2 - DC BOX -48V DC

    DC BOX - RRU B2

    -48V DC

    RRU C1 - DC BOX -48V DC

    DC BOX - RRU C1 -48V DC

    2x10mm2

    DC Power cable

    RRU C1 - DC BOX -48V DC

    DC BOX - RRU C1 -48V DC

    RRU C2 - DC BOX -48V DC

    DC BOX - RRU C2 -48V DC

    2x10mm2

    DC Power cable

    RRU C2 - DC BOX -48V DC

    DC BOX - RRU C2 -48V DC

    MU1 RRUA1 Optical fiber

    RRUA1 MU1 Optical fiber

    Optical fiber

    TSR 899 088/4

    RRUA1 MU1 Optical fiber

    MU1 RRUA1 Optical fiber

    MU1 RRUA2 Optical fiber

    RRUA2 MU1 Optical fiber

    Optical fiber

    TSR 899 088/4

    RRUA2 MU1 Optical fiber

    MU1 RRUA2 Optical fiber

    MU1 RRUB1 Optical fiber

    RRUB1 MU1 Optical fiber

    Optical fiber

    TSR 899 088/4

    RRU B1 MU1 Optical fiber

    MU1 RRUB1 Optical fiber

    MU2 RRUB2 Optical fiber

    RRUB2 MU2 Optical fiber

    Optical fiber

    TSR 899 088/4

    RRUB2 MU2 Optical fiber

    MU2 RRUB2 Optical fiber

    MU1 RRU C1 Optical fiber

    RRU C1 MU1 Optical fiber

    Optical fiber

    TSR 899 088/4

    RRU C1 MU1 Optical fiber

    MU1 RRU C1 Optical fiber

    MU2 RRU C2 Optical fiber

    RRU C2 MU2 Optical fiber

    Optical fiber

    TSR 899 088/4

    RRU C2 MU2 Optical fiber

    MU2 RRU C2 Optical fiber

    MU1 DDF

    DDF MU1

    Local

    Traffic Cable

    DDF MU1

    MU1 DDF

    MU2 DDF

    DDF MU2

    Local

    Traffic Cable

    DDF MU2

    MU2 DDF

    MU2 MU1

    MU1 MU2

    Local

    Traffic Cable

    MU1 MU2

    MU2 MU1 MU1 MU2

    MU2 MU1

    TG Sync Cable

    MU2 MU1

    MU1 MU2

  • PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    2x10mm2

    DC Power cable

    PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    2x10mm2

    DC Power cable

    PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    2x10mm2

    DC Power cable

    PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    2x10mm2

    DC Power cable

    PBC - DC-BOX -48V DC

    DC-BOX - PBC

    -48V DC

    PBC MU PBC BU -48V DC

    PBC BU PBC MU

    -48V DC

    2x10mm2

    DC Power cable

    PBC BU PBC MU -48V DC

    PBC MU PBC BU

    -48V DC

    PBC MU PBC BU -48V DC

    PBC BU PBC MU

    -48V DC

    2x10mm2

    DC Power cable

    PBC BU PBC MU -48V DC

    PBC MU PBC BU

    -48V DC

    PBC MU PBC BU

    PBC BU PBC MU

    TPM1010023/10

    Alarm cable

    PBC BU PBC MU

    PBC MU PBC BU

    PBC MU MU

    MU PBC MU

    TPM1010023/10

    Alarm cable

    MU PBC MU

    PBC MU MU

    DC BOX- NPU3/3B

    -48V DC Out

    NPU3/3B- DC BOX -48 VDC In

    DC Cable

    NPU3/3B- DC BOX

    -48 VDC In

    DC BOX- NPU3/3B -48V DC Out

    DDF NPU3/3B E1 Cable

    NPU3/3B - DDF E1 Cable

    Local

    Traffic Cable

    NPU3/3B - DDF E1 Cable

    DDF NPU3/3B E1 Cable

    Near Site

    Radio Unit

    Facing ..

    RF Cable From MMU..... Pos 1

    Radio Cable

    RF Cable

    From MMU.. Pos 1

    Radio Unit Facing

    Radio Unit

    Facing ..

    RF Cable From MMU.. Pos 2

    Radio Cable

    RF Cable

    From MMU.. Pos 2

    Radio Unit Facing

    Far Site

    Radio Unit

    Facing ..

    RF Cable From MMU..... Pos 1

    Radio Cable

    RF Cable

    From MMU.. Pos 1

    Radio Unit Facing

    Radio Unit

    Facing ..

    RF Cable From MMU.. Pos 2

    Radio Cable

    RF Cable

    From MMU.. Pos 2

    Radio Unit Facing