Shin Nippon General Presentation for Americas Feb2011

15
High Efficiency Steam Turbine Generators Shin Nippon Machinery Co. Introducing

Transcript of Shin Nippon General Presentation for Americas Feb2011

Page 1: Shin Nippon General Presentation for Americas Feb2011

High Efficiency Steam Turbine Generators

Shin NipponMachinery Co.

Introducing

Page 2: Shin Nippon General Presentation for Americas Feb2011

• Established in 1951

• Wholly owned subsidiary of Sumitomo Heavy Industries

• Annual Sales $ 340 million

• 400 Employees

• Capacity to mfg 70 multistage + 100 single stage steam turbines / yr

Page 3: Shin Nippon General Presentation for Americas Feb2011

• KURE WORKS

(HIROSHIMA-KURE)

TOKYO

HEAD OFFICE

KURE CITY

Page 4: Shin Nippon General Presentation for Americas Feb2011

• All Steam Turbines madeat SNM factory in Japan.No mfg outsourcing tothird world.

• Factory at Kure City nearHiroshima has direct access to port.

• Equipment loaded forinternational export withno trucking within Japan.

History of Reliable, On -Time Deliveries

Page 5: Shin Nippon General Presentation for Americas Feb2011

USA

MexicoDominicanRepublic

Trinidad & Tobago

Cuba

Venezuela

Ecuador

PeruBrazil

Chile

Argentina

Algeria Egypt

Nigeria Sudan

South Africa

Poland

Spain

Slovakia

Bulgaria

Romania

Saudi

KuwaitIraq

Iran

Qatar

UAEUAEUAEUAE

Bahrain

Russia

Turkmenistan

UzbekistanChina

BangladeshPakistan

India

North KoreaKorea Japan

Thailand

Myanmar

MalaysiaVietnam

Singapore

Brunei

Indonesia

MacaoHong Kong

Australia

New Caledonia Fiji

Turkey

Canada

NicaraguaBarbados

PanamaCosta Rica

Honduras

Colombia

Bolivia

Uruguay

Guiana

LiberiaGhana

Niger

Tanzania

Malawi

MoroccoTunisia

Germany

Austria

Oman

Cambodia

Sri Lanka

Papua New Guinea

Philippine

Taiwan

Uganda

Belarus

Total Countries ::::81Total Units: 6,592

Shin Nippon Steam Turbine Deliveries 1970 – 2010

Page 6: Shin Nippon General Presentation for Americas Feb2011

35 Steam Turbine GeneratorsIn all regions of USA and Canada

Page 7: Shin Nippon General Presentation for Americas Feb2011

№ MODELDRIVEN

MACHINEQ'TY

OUTPUT

(kW)

SPEED

(RPM)END USER COUNTRY YEAR

1 B6-R4-R Generator 1 4000 6686 DAVIS HAMAKUA SUGAR COMPANY USA 198012

2 C10-R9 Generator 1 7500 3600 THEO DAVIES HAMAKUA SUGAR USA 198312

3 C8-R13-ER Generator 1 7165 5021 CHAPLEAU CO-GENERATION Canada 198606

4 B4-R4-R SHRED 1 1866 9055 HAMAKUA SUGAR COMPANY USA 198601

5 C6-R13-ER Generator 1 8030 5795 CHINO CO-GENERATION PROJECT USA 198707

6 C6-R13-ER Generator 1 7950 5795 CAMARILLO STATE HOSPITAL USA 198707

7 C8-R13-AR Generator 1 10500 5005 CARSON CO-GENERATION PLANT USA 198901

8 C8-R14-ER Generator 1 11600 5005 O'BRIEN CALIFORNIA COGENERATION LTD USA 198902

9 C9-R13-R Generator 1 12500 4041 MALETTE KRAFT PULP AND POWER LTD Canada 198905

10 B6-R4-R SHREDE 1 3728 7492 COMMERCIAL & SUGAR CO.,LTD HAWAIIAN USA 198812

11 B6-R7-R Generator 1 9800 5723 EXXON COMPANY U.S.A. SYU PROJECT USA 199103

12 C8-CR15-ER Generator 1 10600 5023 LOS ANGELES COUNTY SANITATION DISTRICT USA 198910

13 C8-R12-ER Generator 1 8000 5021 WATSONVILE CO-GENERATION PROJECT USA 198912

14 C8-R9-ER Generator 1 15400 4985 HAWKER SIDDLEY POWER ENGINEERING INC USA 199004

15 C10-R13-E Generator 1 22000 3600 SOUTH GLENS FALLS COGENE USA 199011

16 C10-R13-E Generator 1 22000 3600 CARTHAGE COGENERATION USA 199011

17 C6-R13-ER Generator 1 7535 5800 AGNEWS STATE HOSPITAL USA 199007

18 C9-R12-ER Generator 1 14500 4200 UCLA COGENERATION CHILLER PLANT USA 199210

North American Installations – Sheet 1 of 2

Page 8: Shin Nippon General Presentation for Americas Feb2011

North American Installations – Sheet 2 of 2

№ MODELDRIVEN

MACHINEQ'TY

OUTPUT

(kW)

SPEED

(RPM)END USER COUNTRY YEAR

19 C8-R12-ER Generator 1 10500 5000 ICE FLOE COGENERATION PROJECT USA 199407

20 C9-R15-ER Generator 1 25600 4900 CANADIAN GAS & ELECTRIC INC Canada 200209

21 C8-R12-R Generator 1 8475 6194 CITY OF CORONA USA 200307

22 B8-R8-ER Generator 1 25000 4200 WHITE MOUNTAIN ENERGY, LLC USA 200311

23 C6-R9-ER Generator 1 8700 7800 COUNTY SANITATION DISTRICTS OF LOS ANGELES COUNTY USA 200510

24 B8-R4-ER Generator 1 14210 5000 BETHEL ENERGY LLC USA 200909

25 C10-R10-EX Generator 1 38690 3600 BETHEL ENERGY LLC USA 200909

26 C11-R16-EX Generator 1 67000 3600 SUN COKE COMPANY USA 200803

27 C9-R12-ER Generator 1 25000 4200 BULL MOOSE ENERGY LLC USA

28 C10-R15-EX Generator 1 39200 3600 WESTERN WATER AND POWER LIMITED, LLC USA

29 B6-R8-ER Generator 1 9300 5300 PRATT INDUSTRIES (USA) MILL DIVISION CONYERS USA 200808

30 B6-R3-R Generator 1 8500 6500 THOROLD COGEN, L.P Canada 200903

31 C11-R13-EX Generator 1 48000 3600 ZELLSTOFF CELGAR LIMITED PARTNERSHIP Canada 200909

32 C11-R16-EX Generator 1 67000 3600 SUN COKE COMPANY USA 200903

33 C11-R12-EX Generator 1 60000 3600 VISION POWER SYSTEMS, INC. USA 999912

34 C10-R14-ARX Generator 1 28000 4300 FORT NELSON GENERATING STATION Canada 201101

35 C11-R16-EX Generator 1 67000 3600 FITZGERALD RENEWABLE ENERGY, LLC. USA 201010

Page 9: Shin Nippon General Presentation for Americas Feb2011

• Inlet Steam Conditions – Up To 130 Bar (1850 PSI)– Up To 550℃ (1022 F)

• Exhaust Steam Conditions– Condensing or Back Pressure

• Output & Speed– 1Kw To 80,000 Kw– Direct Drive or Geared

Product Design & Capabilities

Impulse BladingReduces Performance Loss Over Time

Page 10: Shin Nippon General Presentation for Americas Feb2011

Direction of Exhaust Outlet OUTPUT (MW)Axial Down Up Side

B4B5B6B8

B10C4C5C6C7C8C9

C10C11

○○○○ ○○○○ ○○○○

20 40 60 80 100

○○○○ ○○○○ ○○○○

○○○○ ○○○○ ○○○○

○○○○ ○○○○

○○○○ ○○○○

○○○○ ○○○○

○○○○ ○○○○

○○○○ ○○○○ ○○○○

○○○○ ○○○○ ○○○○

○○○○ ○○○○ ○○○○

○○○○ ○○○○ ○○○○

○○○○ ○○○○

○○○○ ○○○○

Model

Steam Turbine Models & Exhaust Configurations

B = BackpressureC = Condensing

Page 11: Shin Nippon General Presentation for Americas Feb2011

Axial Exhaust vs. Down Exhaust

Down ExhaustSteam Turbine on Mezzanine

Axial ExhaustSteam Turbine & Condenser

at same level

Condenser

Page 12: Shin Nippon General Presentation for Americas Feb2011

Sun Coke CorporationHaverhill, Ohio

• Model C11-R16-EX

• 67,000 kW Brush Generator

• 3600 RPM – Direct Drive

• Inlet 1555 psia x 1000 F

• Woodward Sliding Pressure Controls

• Exhaust 1.35 psia ( 2.7” Hga)

• 2 Bleed Extractions

Typical Axial ExhaustInstallation

Page 13: Shin Nippon General Presentation for Americas Feb2011

The Axial Exhaust AdvantageSteam Turbine & Condenser

at same level

Shin Nippon Models Available with Axial Exhaust

No Additional Price or Delivery

Efficiency Improvement - Reduces Steam Turbine Exhaust Loss

Cost Reduction – Reduces building height and size of foundations

Quicker Installation – Far less site labor required

Page 14: Shin Nippon General Presentation for Americas Feb2011

Shin Nippon Factory Testing• Every turbine tested

at no -load, 100% rpm

• Contract Controls Utilized for shop test

• Live Steam Checkson Casing and Sealing

Reduces Surprises at Jobsite

Page 15: Shin Nippon General Presentation for Americas Feb2011

Shin Nippon = Your Best Choice1 to 80 MW Steam Turbine Gensets

• 60 Years of Experience• High Efficiency Design• Axial Exhaust Configuration• Direct Drive for most applications• History of On -Time Shipment

Competitive Price & Delivery