5
 SFC 332N / SFC 332P Dynamic Flow Comput ers, Inc. © 2012 The SFC332 is a dual meter bi-directional field mounted flow computer which can be used for all liquid and gas applications, including custody or non-custody measurements. Using orifice plate, Venturi, turbine/PD/ultrasonic mass meter, or wedge devices, it can meter a wide variety of products, such as crude, refined product, LPG/NGL products, products that use table 24C, ethylene, propylene, and water. Fifty days of previous daily data, fifty previous batch data, and fifty previous hourly data are stored in the full format type reports. The previous 100 audit trail reports and 100 alarm reports are stored. User formatted reports and user formatted ticket reports are available. Sixteen different product files are user-configurable and stored in memory with an easy switch feature to enable the user to choose which product is being monitored at any given time. Product scheduling for batch operation is also available. SFC332P SFC332P prover flow computers store data for up to 60 meters and can easily be configured from inside a vehicle with a laptop. With the push of a button proving is initiated for any of the 60 meters. The flow computer controls the proving process and generates all the proving reports. When proving is complete a printed report is automatically generated to a serial printer port. The data can also be retrieved via a laptop at any time. The SFC332P can be mounted on a prover trailer, which can be moved from field to field to provide proving services. Features  Applications 32-bit processor Liquid and gas measurement Multiple I/O options Wellhead measurement & automation Custody transfer accuracy Custody measurement and control Turbine diagnostics Compressor stations Battery backup /UPS Well optimization PID control Prover (SFC332P) Additional I/O options Reports/Storage Stationary or portables Daily Dual or single detectors Hourly Supports 4-way valve control Monthly Monthly day by day Communications RS232 Modbus Alternative Power RS485 Modbus Extended length battery backup Analog and digital I/O Solar powered

Transcript of SFC 332 Data Sheet

Page 1: SFC 332 Data Sheet

7/22/2019 SFC 332 Data Sheet

http://slidepdf.com/reader/full/sfc-332-data-sheet 1/4

 SFC 332N / SFC 332P

Dynamic Flow Computers, Inc. © 2012

The SFC332 is a dual meter bi-directional field

mounted flow computer which can be used for all liquid and

gas applications, including custody or non-custody

measurements. Using orifice plate, Venturi,

turbine/PD/ultrasonic mass meter, or wedge devices, it can

meter a wide variety of products, such as crude, refinedproduct, LPG/NGL products, products that use table 24C,

ethylene, propylene, and water. Fifty days of previous daily

data, fifty previous batch data, and fifty previous hourly data

are stored in the full format type reports. The previous 100

audit trail reports and 100 alarm reports are stored. User

formatted reports and user formatted ticket reports are

available.

Sixteen different product files are user-configurable

and stored in memory with an easy switch feature to enable

the user to choose which product is being monitored at any

given time. Product scheduling for batch operation is also

available.

SFC332P

SFC332P prover flow computers store data for up to 60 meters and can easily be configured from

inside a vehicle with a laptop. With the push of a button proving is initiated for any of the 60 meters.

The flow computer controls the proving process and generates all the proving reports. When proving

is complete a printed report is automatically generated to a serial printer port. The data can also be retrieved

via a laptop at any time.

The SFC332P can be mounted on a prover trailer, which can be moved from field to field to provide

proving services.

Features   Applications

32-bit processor Liquid and gas measurement

Multiple I/O options Wellhead measurement & automation

Custody transfer accuracy Custody measurement and control

Turbine diagnostics Compressor stations

Battery backup /UPS Well optimization

PID control

Prover (SFC332P)

Additional I/O options Reports/Storage 

Stationary or portables Daily

Dual or single detectors Hourly

Supports 4-way valve control Monthly

Monthly day by day

Communications RS232 Modbus  Alternative Power

RS485 Modbus Extended length battery backup

Analog and digital I/O Solar powered

Page 2: SFC 332 Data Sheet

7/22/2019 SFC 332 Data Sheet

http://slidepdf.com/reader/full/sfc-332-data-sheet 2/4

 SFC 332N / SFC 332P

Dynamic Flow Computers, Inc. © 2012

The input/output assignment, flow equations, historical data storage, and other functions are carried

out using Dynamic Flow Computers’ DYNACOM® software. This software is Windows based, free of charge,

and available for download/update at any time on our website.

DYNACOM ®  Software Capabilities:

  Flow computer diagnostics  Configure inputs and outputs

  Configure PID control

  Personalize report time and content

  Configure and select the local LCD screen displayed parameters

  Reassign and customize MODBUS® registers and values

  Create and implement custom math and formulas

  Input and output calibration

  Automatic and periodic downloading of flow computer reports

  Obtain historic data for display, saving, exportation, or printing

Historic data is available in the memory of the flow computer for download or display.

Maximum Report Storage:

  Hourly reports: 1536 hours*

  Daily reports: 64 *

  Daily reports, hour by hour: 64*

  Monthly reports: 6*

  Monthly, day by day: 2 months*

  Calibration reports: 20*

  Audit reports: 100*

  Alarm reports: 100*

  Special reports: HTML, and others

*The number of reports stored can vary according to application.

PHYSICAL SPECIFICATIONS

Electrical/Conduit Connections Three 3/4" NPT.

Housing (Flow Computer) NEMA 4X class 1 div. 1 –  IP66

RTD Connection To flow computer terminal block

Display Plasma; 2 Lines x 16 characters each line.

Temperature LimitsOperation: -40 to 185 °F (-40 to 85 °C)

Storage: -50 to 190 °F (-46 to 87 °C)

Humidity 100%

ELECTRICAL SPECIFICATIONS

Voltage 12 to 30 VDC

Power Consumption 4 watt

Solar Board (Optional) 10/20 watts, 12 volts

Polarity Reverse polarity protected

Processor 32 bits @ 16.7Mhz

FLASH ROM 4 MB @ 70 NANO seconds

ROM 2 MB @ 30 NANO seconds

Real Time Clock Years/Months/Days/Hours/Minutes

Page 3: SFC 332 Data Sheet

7/22/2019 SFC 332 Data Sheet

http://slidepdf.com/reader/full/sfc-332-data-sheet 3/4

 SFC 332N / SFC 332P

Dynamic Flow Computers, Inc. © 2012

INPUT SPECIFICATIONS

Optic Isolation Each input is optically isolated with ±250 VDC chassis isolation

Analog Input

Four 4-20mA (or 0-5V) Inputs

(expandable to 6 inputs)

Resolution 24 bits

Pulse/Frequency Input

Three inputs (expandable to 4)

0 - 5000 HZ

Signal must be > 70 mV for sine wave

Signal must be > 6 volts for square wave

Input 3 is for square wave only

Digital/Switch Input

Four inputs

7-24VDC

0.25 Amp rating

RTD Input

Two inputs

(RTD Input uses/disables 2 analog inputs)

Direct connection to flow computer

4-wire RTD, 24 bit resolution

OUTPUT SPECIFICATIONS

Optic IsolationEach output is optically isolated with ±250 VDC chassis/ground

isolation

Digital/Switch Output

Three outputs

7-24VDC

0.25 Amp rating

Pulse Output

Two outputs

(can also be assigned as digital output for a total of 5 digital

outputs)

7-24VDC

0.5 Amp rating

On/Off or pulses (to 125 pulses/sec.)

Analog Output

Two outputs

4-20mA (external power required)

For PID control or for data transmission

Resolution 12 bits single ended

COMMUNICATION SPECIFICATIONS

RS485 Quantity 2 @ 1200 –  38400 bps

RS232 Quantity 1 @ 1200 –  19200 bps

Protocol MODBUS® RTU/ASCII

DIAGNOSTIC SPECIFICATIONS

Monitor/Alarm

Multivariable: P, DP, T

Analog Inputs/outputsDigital/switch inputs

Digital/switch outputs

Pulse/frequency inputs

Internal temperature

Battery voltage

Internal power supply

Page 4: SFC 332 Data Sheet

7/22/2019 SFC 332 Data Sheet

http://slidepdf.com/reader/full/sfc-332-data-sheet 4/4

 SFC 332N / SFC 332P

Dynamic Flow Computers, Inc. © 2012

FLOW COMPUTATION SPECIFICATIONS

Number of Trains Two bi-directional (dependent on application)

Flow Calculation Simultaneous gas and liquid

Primary Elements

Differential:

Orifice, V-Cone, Wedge, Annubar, Venturi, etc.

Pulse/Frequency:

Turbine, PD, Vortex, Ultrasonic, etc.

Engineering Units US and Metric

Base Conditions60°F, 14.7 Psia (15 °C and 1 Kg. /Cm²)

68°F, 14.7 Psia (20 °C and 1 Kg/Cm²)

Equations

AGA3, API14.3, AGA7, AGA9, API5.6, API5.7, AGA8 methods 1,

2, and detailed; API 2540; API11-2-1, 11-2-1M; 11-2,2, 11-2-2M;

GPA15, 16; API2565; tables 5A,B; 6A,B,C; 23A,B,C; 24A,B,C;

53A,B; 54A,B,C; 23 and 24.

Others added continuously

Consult factory for complete list

Optional Accessories 

RS-232 Elbow SmartCone®

Armored RTD Cable Solar Panel

Rosemount ®  205 Module