B-Curve-e-82SC
Series e-82SCSplit-Coupled Twin Vertical In-Line Mounted Centrifugal Pump Performance Curves
Now includes
U.S. Dept. of Energy
Pump Energy Index Fund
-
2
Service and support from the most trusted name in the industry – Bell & Gossett
The Bell & Gossett name has always stood for uncompromising quality and dependability. That’s evident in the way every one of our centrifugal pumps is built and backed by our outstanding customer service and support team.
Your local Bell & Gossett representative is available any time and is an experienced professional with a wealth of technical expertise. In addition to expert system and product application assistance and a wide product inventory warehoused locally, we offer ESP-Systemwize software selection program.
ESP-Systemwize is a Bell & Gossett web-based software that helps you design HVAC systems accurately, effectively and very quickly. You get fast, precise equipment selection, pump performance curves and equipment schedules, submittals, specifications and more.
ESP-Systemwize includes:
• Centrifugal Pumps • Expansion Tanks
• Air/Dirt Separators • Heat Exchangers
• Drives and Controls • PIC Valves
• Replacement Parts
• Suction Diffuser and Triple Duty Valve
• Wastewater/Stormwater
www.esp-systemwize.com
-
3
TABLE OF CONTENTSModel List 4
e-82SC Pump Performance Range (Standby Operation) 4
General Introduction 5
e-82SC General Exploded View 6
Mechanical Seals 7
Material Configurations 7
e-82SC Pump Accessories 8
Blind Flange 8
Variable Frequency Drives (VFDs) Overview 8
e-82SC Pump Dimensional Data 10
e-82SC 2.5x2.5x7 10
e-82SC 2.5x2.5x9.5 12
e-82SC 3x3x7 14
e-82SC 3x3x9.5 16
e-82SC 3x3x11 18
e-82SC 4x4x7 20
e-82SC 4x4x9.5 22
e-82SC 4x4x11 24
e-82SC 6x6x7 26
e-82SC 6x6x9.5 28
e-82SC 6x6x11 30
e-82SC Pump Performance Data (Standby Operation) 32
6 Pole Performance Data 32
e-82SC 2.5x2.5x7 32
e-82SC 2.5x2.5x9.5 32
e-82SC 3x3x7 33
e-82SC 3x3x9.5 33
e-82SC 3x3x11 34
e-82SC 4x4x7 34
e-82SC 4x4x9.5 35
e-82SC 4x4x11 35
e-82SC 6x6x7 36
e-82SC 6x6x9.5 36
e-82SC 6x6x11 37
4 Pole Performance Data 38
e-82SC 2.5x2.5x7 38
e-82SC 2.5x2.5x9.5 38
e-82SC 3x3x7 39
e-82SC 3x3x9.5 39
e-82SC 3x3x11 40
e-82SC 4x4x7 40
e-82SC 4x4x9.5 41
e-82SC 4x4x11 41
e-82SC 6x6x7 42
e-82SC 6x6x9.5 42
e-82SC 6x6x11 43
2 Pole Performance Data 44
e-82SC 2.5x2.5x7 44
e-82SC 2.5x2.5x9.5 44
e-82SC 3x3x7 45
e-82SC 4x4x7 45
e-82SC 6x6x7 46
Useful Pump Formulas 47
Affinity Laws: Effect of varying speed or impeller diameter. 47
-
4
MODEL LIST
e-82SC PUMP PERFORMANCE RANGE (STANDBY OPERATION)
160
140
120
100
80
60
40
20
0
Hea
d (F
eet)
Flow (GPM)10 100 1000 10000
6x9.5B
3x11B3x9.5C
4x11B
6x7B4x7B
4x9.5B
3x7C
Series e-82SC1750 RPM
6x11B
2.5x9C
2.5x7B
450
400
350
300
250
200
150
100
50
0
Hea
d (F
eet)
Flow (GPM)10 100 1000
3x7C
Series e-82SC3550 RPM
4x7B
2.5x9.5C
2.5x7B6x7B
No. e-82SC Model1 2-Pole 4-Pole 6-Pole
1 2.5x2.5x7 • • •
2 2.5x2.5x9.5 • • •
3 3x3x7 • • •
4 3x3x9.5 • •
5 3x3x11 • •
6 4x4x7 • • •
7 4x4x9.5 • •
8 4x4x11 • •
9 6x6x7 • • •
10 6x6x9.5 • •
11 6x6x11 • •
1Pump model nomenclature: (Discharge diameter) x (Suction diameter) x (Impeller diameter) in inches
-
5
GENERAL INTRODUCTION The e-82 and e-82SC twin vertical in-line centrifugal pumps are an ideal solution for parallel staging or back-up capacity. Our expanded line of energy efficient in-line pumps include 11 new close coupled and 11 new split coupled models. The pumps are stainless steel fitted, matching the hydraulics and the flange to flange dimensions of the current pumps, with double the power in a compact footprint. Parallel pumping provides redundant capacity and the capability to meet duty requirements with smaller horsepower motors and drives and improved pump efficiency at reduced flow. As system load is reduced, pumps can be de-staged to achieve higher motor and drives efficiencies.
Applications • Hydronic heating and cooling systems • Light industrial process • General service • Pressure boosting • OEM applications
Hydraulic Specifications • Maximum flow: approx. 1,400 GPM standby and approx. 2,500 GPM parallel • Maximum head: approx. 400 ft. • Hydraulic performance compliant with ANSI/HI 14.6 and ISO 9906:2012 (Grade 2B)
Fluid Temperature Range • Standard configuration: -20 to 225°F
Maximum Operating Pressure • Casing working pressure: 175 psi
Flange Drilling Specifications • ASME/ANSI B16.1, 125#
Motor Specifications • NEMA Premium efficiency per EISA 2010 • 2, 4, 6-pole ranges • Maximum 3-phase ambient temperature: 104°F [40°C] • Inverter-Duty Ready • Open Drip Proof (ODP) enclosure (standard) • Performances according to NEMA MG-1 • Class F insulation • Standard voltages: Three Phase, 208/230/460 Volt
-
6
e-82SC GENERAL EXPLODED VIEW
19
14
12
15
6
3
5
102
21
2322
9
11
4
21
8
7
17
13
20
16
18
NO Description QTY
1 Volute 1
2 Volute Gasket 2
3 Volute Capscrew *
4 Impeller 2
5 Throttle Bushing (Bearing) 2
6 Inside Mechanical Seal 2
7 Outside Mechanical Seal 2
8 Motor Bracket 8
9 Impeller Bolt 2
10 Impeller Lockwasher 2
11 Impeller Washer 2
12 Impeller Key 2
13 Shaft 2
14 Coupler Key 2
15 Tapered Capscrew Kit 2
16 Coupler, Split 2
17 Collar 2
18 Motor Bracket Capscrew 8
19 Motor 2
20 Guard 2
21 Flush Line Assembly 1
22 Flapper Assembly 1
23 Self Sealing Screw 2
e-82SC LEGEND
*Quantity varies with pump size
-
7
MECHANICAL SEALSe-82SC Standard Seal Configuration e-82SC Optional Seal Configuration
MaterialStandard,
EPR/Carbon/Ceramic
Optional,Viton/Carbon/
Ceramic
Optional,EPR/Carbon/
TungstenCarbide¹
Optional,EPR/Silicon
Carbide/SiliconCarbide¹
Optional, Viton/Carbon/
TungstenCarbide¹
Operating temperature range
-20 to 250 °F -10 to 225 °F -20 to 250 °F -20 to 250 °F -20 to 250 °F
pH range limits 7.0 to 9.0 7.0 to 9.0 7.0 to 11.0 7.0 to 12.5 7.0 to 9.0
Resistance to dissolved solids
Low Low Low-Medium Medium-High Low-Medium
Maximum glycol/water concentration
50/50% 50/50% 50/50% 60/40% 50/50%
1Requires external flush
MATERIAL CONFIGURATIONSComponent Standard Option Other Options
Casing Cast Iron Ductile Iron –
Impeller Stainless Steel –
Wear Ring – Stainless Steel
Other Accessories
Sight Flow Indicator1
Cuno Filter2
Sediment Separator2
Heat Exchanger3
Flange Supports
Blind Flange
1Available installed with flush line only2Available installed with a sight flow indicator or as a standalone kit 3Available as kit only
-
8
e-82SC PUMP ACCESSORIESBlind Flange Description • When the blind flange is installed, one of the e-82SC twin
in-line pump rotating assemblies may be removed. This allows for the pump to operate in standby mode while maintenance can be performed on the non-operational motor or rotating assembly. Refer to the e-82SC pump instruction manual for more information about the e-82SC blind flange.
Variable Frequency Drives (VFDs) Overview Description • Integrated Technologic® IPC Variable Speed Controller Attributes • 230/460/575V • 1.5 to 125 hp range options • Temperature rating: 14°F to 113°F [-10°C to 45°C] • Sensored or sensorless control • Built-in BACnet, Modbus RTU, N2 Metasys, FLN • 2 analog inputs, 1 analog output • 4 digital inputs, 2 digital outputs • Mains disconnect with optional fuses • UL TYPE 12 & IP55 enclosure • Certified by ETL • Fan-cooled via temperature controller
-
9
-
10
e-82SC PUMP DIMENSIONAL DATA e-82SC 2.5x2.5x7
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLE1/4” NPT
1/4” NPT
GAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
V
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 2”, 125#ANSI FLANGE TOSUPPORT PUMP
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
143TC9.00(229)
18.00(457)
12.19(310)
12.58(320)
12.05(306)
11.66(296)
6.00(152)
29.71(755)
5.50(140)
40.75(19)
7.19(183)
4.50(114)
145TC9.00(229)
18.00(457)
12.19(310)
12.58(320)
12.05(306)
11.66(296)
6.00(152)
29.71(755)
5.50(140)
40.75(19)
7.19(183)
4.50(114)
182TC9.00(229)
18.00(457)
12.19(310)
12.58(320)
12.25(311)
11.94(303)
6.00(152)
30.19(767)
5.50(140)
40.75(19)
8.75(222)
4.50(114)
184TC9.00(229)
18.00(457)
12.19(310)
12.58(320)
13.25(337)
11.94(303)
6.00(152)
31.19(792)
5.50(140)
40.75(19)
8.75(222)
4.50(114)
213TC9.00(229)
18.00(457)
12.19(310)
12.58(320)
14.88(378)
11.94(303)
6.00(152)
32.82(834)
5.50(140)
40.75(19)
10.63(270)
4.50(114)
215TC9.00(229)
18.00(457)
12.19(310)
12.58(320)
14.88(378)
11.94(303)
6.00(152)
32.82(834)
5.50(140)
40.75(19)
10.63(270)
4.50(114)
254TC9.00(229)
18.00(457)
12.19(310)
12.58(320)
19.44(494)
11.94(303)
6.00(152)
37.38(949)
5.50(140)
40.75(19)
12.31(313)
4.50(114)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
-
11
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G H (max)
143TC20.20(513)
23.70(602)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
30.71(780)
145TC20.20(513)
23.70(602)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
30.71(780)
182TC20.20(513)
23.70(602)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
31.19(792)
184TC20.20(513)
23.70(602)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
32.19(818)
213TC20.20(513)
23.70(602)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
33.81(859)
215TC20.20(513)
23.70(602)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
33.81(859)
254TC20.20(513)
23.70(602)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
38.38(975)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
-
12
e-82SC 2.5x2.5x9.5
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
143TC10.75(273)
21.50(546)
14.93(379)
15.36(390)
12.05(306)
11.64(296)
6.25(159)
29.94(760)
5.50(140)
40.75(19)
7.19(183)
4.75(121)
145TC10.75(273)
21.50(546)
14.93(379)
15.36(390)
12.05(306)
11.64(296)
6.25(159)
29.94(760)
5.50(140)
40.75(19)
7.19(183)
4.75(121)
182TC10.75(273)
21.50(546)
14.93(379)
15.36(390)
12.25(311)
11.89(302)
6.25(159)
30.39(772)
5.50(140)
40.75(19)
8.75(222)
4.75(121)
184TC10.75(273)
21.50(546)
14.93(379)
15.36(390)
13.25(337)
11.89(302)
6.25(159)
31.39(797)
5.50(140)
40.75(19)
8.75(222)
4.75(121)
213TC10.75(273)
21.50(546)
14.93(379)
15.36(390)
14.88(378)
11.89(302)
6.25(159)
33.02(839)
5.50(140)
40.75(19)
10.63(270)
4.75(121)
215TC10.75(273)
21.50(546)
14.93(379)
15.36(390)
14.88(378)
11.89(302)
6.25(159)
33.02(839)
5.50(140)
40.75(19)
10.63(270)
4.75(121)
284TSC10.75(273)
21.50(546)
14.93(379)
15.36(390)
22.06(560)
14.70(373)
6.25(159)
43.01(1092)
5.50(140)
40.75(19)
14.13(359)
6.00(152)
286TSC10.75(273)
21.50(546)
14.93(379)
15.36(390)
23.56(598)
14.70(373)
6.25(159)
44.51(1131)
5.50(140)
40.75(19)
14.13(359)
6.00(152)
324TSC10.75(273)
21.50(546)
14.93(379)
15.36(390)
24.63(626)
14.70(373)
6.25(159)
45.58(1158)
5.50(140)
40.75(19)
15.56(395)
6.00(152)
326TSC10.75(273)
21.50(546)
14.93(379)
15.36(390)
26.13(664)
14.70(373)
6.25(159)
47.08(1196)
5.50(140)
40.75(19)
15.56(395)
6.00(152)
364TSC10.75(273)
21.50(546)
14.93(379)
15.36(390)
28.06(713)
14.70(373)
6.25(159)
49.01(1245)
5.50(140)
40.75(19)
18.75(476)
6.00(152)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLE1/4” NPT
1/4” NPT
GAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
V
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 2”, 125#ANSI FLANGE TOSUPPORT PUMP
-
13
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
143TC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
30.69(779)
145TC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
30.69(779)
182TC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
31.14(791)
184TC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
32.14(816)
213TC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
33.76(858)
215TC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
33.76(858)
284TSC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
43.76(1112)
286TSC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
45.26(1150)
324TSC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
46.33(1177)
326TSC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
47.83(1215)
364TSC23.73(603)
27.23(692)
21.50(546)
25.00(635)
0.88(22)
7.00(178)
49.76(1264)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
14
e-82SC 3x3x7
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
143TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
12.05(306)
11.75(298)
6.25(159)
30.05(763)
6.00(152)
40.75(19)
7.19(183)
4.50(114)
145TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
12.05(306)
11.75(298)
6.25(159)
30.05(763)
6.00(152)
40.75(19)
7.19(183)
4.50(114)
182TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
12.25(311)
12.00(305)
6.25(159)
30.50(775)
6.00(152)
40.75(19)
8.75(222)
4.50(114)
184TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
13.25(337)
12.00(305)
6.25(159)
31.50(800)
6.00(152)
40.75(19)
8.75(222)
4.50(114)
213TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
14.88(378)
12.00(305)
6.25(159)
33.13(841)
6.00(152)
40.75(19)
10.63(270)
4.50(114)
215TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
14.88(378)
12.00(305)
6.25(159)
33.13(841)
6.00(152)
40.75(19)
10.63(270)
4.50(114)
254TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
19.44(494)
12.00(305)
6.25(159)
37.69(957)
6.00(152)
40.75(19)
12.31(313)
4.50(114)
256TC9.50(241)
19.00(483)
13.17(334)
13.83(351)
21.19(538)
12.00(305)
6.25(159)
39.44(1002)
6.00(152)
40.75(19)
12.31(313)
4.50(114)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLE1/4” NPT
1/4” NPT
GAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
V
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 2”, 125#ANSI FLANGE TOSUPPORT PUMP
-
15
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
143TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
31.55(801)
145TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
31.55(801)
182TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
32.00(813)
184TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
33.00(838)
213TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
34.63(879)
215TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
34.63(879)
254TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
39.19(995)
256TC20.95(532)
24.45(621)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
40.94(1040)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
16
e-82SC 3x3x9.5
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
143TC11.50(292)
23.00(584)
16.52(420)
16.96(431)
12.05(306)
11.70(297)
6.25(159)
30.00(762)
6.00(152)
40.75(19)
7.19(183)
4.75(121)
145TC11.50(292)
23.00(584)
16.52(420)
16.96(431)
12.05(306)
11.70(297)
6.25(159)
30.00(762)
6.00(152)
40.75(19)
7.19(183)
4.75(121)
182TC11.50(292)
23.00(584)
16.52(420)
16.96(431)
12.25(311)
11.94(303)
6.25(159)
30.44(773)
6.00(152)
40.75(19)
8.75(222)
4.75(121)
184TC11.50(292)
23.00(584)
16.52(420)
16.96(431)
13.25(337)
11.94(303)
6.25(159)
31.44(799)
6.00(152)
40.75(19)
8.75(222)
4.75(121)
213TC11.50(292)
23.00(584)
16.52(420)
16.96(431)
14.88(378)
11.94(303)
6.25(159)
33.07(840)
6.00(152)
40.75(19)
10.63(270)
4.75(121)
215TC11.50(292)
23.00(584)
16.52(420)
16.96(431)
14.88(378)
11.94(303)
6.25(159)
33.07(840)
6.00(152)
40.75(19)
10.63(270)
4.75(121)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
-
17
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
143TC25.10(638)
28.60(726)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
31.50(800)
145TC25.10(638)
28.60(726)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
31.50(800)
182TC25.10(638)
28.60(726)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
31.94(811)
184TC25.10(638)
28.60(726)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
32.94(837)
213TC25.10(638)
28.60(726)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
34.56(878)
215TC25.10(638)
28.60(726)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
34.56(878)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
18
e-82SC 3x3x11
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
213TC12.00(305)
24.00(610)
16.75(425)
16.84(428)
14.88(378)
11.25(286)
6.75(171)
32.88(835)
6.00(152)
40.75(19)
10.63(270)
5.50(140)
215TC12.00(305)
24.00(610)
16.75(425)
16.84(428)
14.88(378)
11.25(286)
6.75(171)
32.88(835)
6.00(152)
40.75(19)
10.63(270)
5.50(140)
254TC12.00(305)
24.00(610)
16.75(425)
16.84(428)
19.44(494)
11.25(286)
6.75(171)
37.44(951)
6.00(152)
40.75(19)
12.31(313)
5.50(140)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
-
19
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
213TC25.94(659)
29.44(748)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
33.88(860)
215TC25.94(659)
29.44(748)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
33.88(860)
254TC25.94(659)
29.44(748)
21.50(546)
25.00(635)
0.88(22)
7.75(197)
38.44(976)
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
20
e-82SC 4x4x7
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
143TC10.50(267)
21.00(533)
14.53(369)
15.12(384)
12.05(306)
11.80(300)
6.91(175)
30.76(781)
7.50(191)
80.75(19)
7.19(183)
4.75(121)
145TC10.50(267)
21.00(533)
14.53(369)
15.12(384)
12.05(306)
11.80(300)
6.91(175)
30.76(781)
7.50(191)
80.75(19)
7.19(183)
4.75(121)
182TC10.50(267)
21.00(533)
14.53(369)
15.12(384)
12.25(311)
12.19(310)
6.91(175)
31.35(796)
7.50(191)
80.75(19)
8.75(222)
4.75(121)
184TC10.50(267)
21.00(533)
14.53(369)
15.12(384)
13.25(337)
12.19(310)
6.91(175)
32.35(822)
7.50(191)
80.75(19)
8.75(222)
4.75(121)
256TC10.50(267)
21.00(533)
14.53(369)
15.12(384)
21.19(538)
12.25(311)
6.91(175)
40.35(1025)
7.50(191)
80.75(19)
12.31(313)
5.00(127)
284TSC10.50(267)
21.00(533)
14.53(369)
15.12(384)
22.06(560)
14.87(378)
6.91(175)
43.84(1113)
7.50(191)
80.75(19)
14.13(359)
6.00(152)
286TSC10.50(267)
21.00(533)
14.53(369)
15.12(384)
23.56(598)
14.87(378)
6.91(175)
45.34(1152)
7.50(191)
80.75(19)
14.13(359)
6.00(152)
324TSC10.50(267)
21.00(533)
14.53(369)
15.12(384)
24.63(626)
14.87(378)
6.91(175)
46.41(1179)
7.50(191)
80.75(19)
15.56(395)
6.00(152)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
-
21
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
143TC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
32.87(835)
145TC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
32.87(835)
182TC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
33.46(850)
184TC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
34.46(875)
256TC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
42.46(1078)
284TSC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
45.95(1167)
286TSC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
47.45(1205)
324TSC22.66(576)
26.16(664)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
48.52(1232)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
22
e-82SC 4x4x9.5
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
182TC12.50(318)
25.00(635)
15.41(392)
16.23(412)
12.25(311)
12.75(324)
7.31(186)
32.31(821)
7.50(191)
80.75(19)
8.75(222)
5.00(127)
184TC12.50(318)
25.00(635)
15.41(392)
16.23(412)
13.25(337)
12.75(324)
7.31(186)
33.31(846)
7.50(191)
80.75(19)
8.75(222)
5.00(127)
213TC12.50(318)
25.00(635)
15.41(392)
16.23(412)
14.88(378)
12.75(324)
7.31(186)
34.94(888)
7.50(191)
80.75(19)
10.63(270)
5.00(127)
215TC12.50(318)
25.00(635)
15.41(392)
16.23(412)
14.88(378)
12.75(324)
7.31(186)
34.94(888)
7.50(191)
80.75(19)
10.63(270)
5.00(127)
254TC12.50(318)
25.00(635)
15.41(392)
16.23(412)
19.44(494)
12.75(324)
7.31(186)
39.50(1003)
7.50(191)
80.75(19)
12.31(313)
5.00(127)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
-
23
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
182TC26.66(677)
30.16(766)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
34.02(864)
184TC26.66(677)
30.16(766)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
35.02(890)
213TC26.66(677)
30.16(766)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
36.65(931)
215TC26.66(677)
30.16(766)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
36.65(931)
254TC26.66(677)
30.16(766)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
41.21(1047)
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
24
e-82SC 4x4x11
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
213TC13.00(330)
26.00(660)
15.88(403)
16.55(420)
14.88(378)
11.44(291)
7.50(191)
33.82(859)
7.50(191)
80.75(19)
8.75(222)
5.75(146)
215TC13.00(330)
26.00(660)
15.88(403)
16.55(420)
14.88(378)
11.44(291)
7.50(191)
33.82(859)
7.50(191)
80.75(19)
8.75(222)
5.75(146)
254TC13.00(330)
26.00(660)
15.88(403)
16.55(420)
19.44(494)
11.44(291)
7.50(191)
38.38(975)
7.50(191)
80.75(19)
10.63(270)
5.75(146)
256TC13.00(330)
26.00(660)
15.88(403)
16.55(420)
21.19(538)
11.44(291)
7.50(191)
40.13(1019)
7.50(191)
80.75(19)
10.63(270)
5.75(146)
284TC13.00(330)
26.00(660)
15.88(403)
16.55(420)
22.06(560)
13.50(343)
7.50(191)
43.06(1094)
7.50(191)
80.75(19)
12.31(313)
5.75(146)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
-
25
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
213TC27.66(703)
31.16(791)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
35.33(897)
215TC27.66(703)
31.16(791)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
35.33(897)
254TC27.66(703)
31.16(791)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
39.90(1013)
256TC27.66(703)
31.16(791)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
41.65(1058)
284TC27.66(703)
31.16(791)
21.50(546)
25.00(635)
0.88(22)
9.02(229)
44.58(1132)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
26
e-82SC 6x6x7
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
143TC14.00(356)
28.00(711)
16.50(419)
17.47(444)
12.05(306)
12.71(323)
8.00(203)
32.76(832)
9.50(241)
80.88(22)
7.19(183)
5.25(133)
145TC14.00(356)
28.00(711)
16.50(419)
17.47(444)
12.05(306)
12.71(323)
8.00(203)
32.76(832)
9.50(241)
80.88(22)
7.19(183)
5.25(133)
182TC14.00(356)
28.00(711)
16.50(419)
17.47(444)
12.25(311)
12.94(329)
8.00(203)
33.19(843)
9.50(241)
80.88(22)
8.75(222)
5.25(133)
184TC14.00(356)
28.00(711)
16.50(419)
17.47(444)
13.25(337)
12.94(329)
8.00(203)
34.19(868)
9.50(241)
80.88(22)
8.75(222)
5.25(133)
213TC14.00(356)
28.00(711)
16.50(419)
17.47(444)
14.88(378)
12.94(329)
8.00(203)
35.82(910)
9.50(241)
80.88(22)
10.63(270)
5.25(133)
215TC14.00(356)
28.00(711)
16.50(419)
17.47(444)
14.88(378)
12.94(329)
8.00(203)
35.82(910)
9.50(241)
80.88(22)
10.63(270)
5.25(133)
286TSC14.00(356)
28.00(711)
16.50(419)
17.47(444)
23.56(598)
15.67(398)
8.00(203)
47.23(1200)
9.50(241)
80.88(22)
14.13(359)
6.00(152)
324TSC14.00(356)
28.00(711)
16.50(419)
17.47(444)
24.63(626)
15.67(398)
8.00(203)
48.30(1227)
9.50(241)
80.88(22)
15.56(395)
6.00(152)
326TSC14.00(356)
28.00(711)
16.50(419)
17.47(444)
26.13(664)
15.67(398)
8.00(203)
49.80(1265)
9.50(241)
80.88(22)
15.56(395)
6.00(152)
364TSC14.00(356)
28.00(711)
16.50(419)
17.47(444)
28.06(713)
15.67(398)
8.00(203)
51.73(1314)
9.50(241)
80.88(22)
18.75(476)
6.00(152)
365TSC14.00(356)
28.00(711)
16.50(419)
17.47(444)
28.06(713)
15.67(398)
8.00(203)
51.73(1314)
9.50(241)
80.88(22)
18.75(476)
6.00(152)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
-
27
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
143TC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
34.63(880)
145TC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
34.63(880)
182TC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
35.06(891)
184TC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
36.06(916)
213TC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
37.69(957)
215TC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
37.69(957)
286TSC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
49.10(1247)
324TSC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
50.17(1274)
326TSC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
51.67(1312)
364TSC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
53.60(1362)
365TSC29.50(749)
33.00(838)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
53.60(1362)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
28
e-82SC 6x6x9.5
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
213TC16.75(425)
33.50(851)
20.82(529)
22.83(580)
14.88(378)
12.56(319)
9.29(236)
36.73(933)
9.50(241)
80.88(22)
10.63(270)
5.50(140)
215TC16.75(425)
33.50(851)
20.82(529)
22.83(580)
14.88(378)
12.56(319)
9.29(236)
36.73(933)
9.50(241)
80.88(22)
10.63(270)
5.50(140)
254TC16.75(425)
33.50(851)
20.82(529)
22.83(580)
19.44(494)
12.56(319)
9.29(236)
41.29(1049)
9.50(241)
80.88(22)
12.31(313)
5.50(140)
256TC16.75(425)
33.50(851)
20.82(529)
22.83(580)
21.19(538)
12.56(319)
9.29(236)
43.04(1093)
9.50(241)
80.88(22)
12.31(313)
5.50(140)
284TC16.75(425)
33.50(851)
20.82(529)
22.83(580)
22.06(560)
15.13(384)
9.29(236)
46.48(1180)
9.50(241)
80.88(22)
14.13(359)
5.50(140)
286TC16.75(425)
33.50(851)
20.82(529)
22.83(580)
23.56(598)
15.13(384)
9.29(236)
47.98(1219)
9.50(241)
80.88(22)
14.13(359)
5.50(140)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
-
29
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
e-82SC with Flange SupportDIMENSIONS – inches (mm)
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
213TC34.78(883)
38.28(972)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
37.31(948)
215TC34.78(883)
38.28(972)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
37.31(948)
254TC34.78(883)
38.28(972)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
41.88(1064)
256TC34.78(883)
38.28(972)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
43.63(1108)
284TC34.78(883)
38.28(972)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
47.06(1195)
286TC34.78(883)
38.28(972)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
48.56(1233)
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
30
e-82SC 6x6x11
V
GAUGE TAP
DISCHARGE SUCTION
DRAIN HOLES1/4” NPT
1/4” NPTGAUGE TAP
SPACE REQUIREDFOR DISMANTLING
1/4” NPT
A AB
MOTOR MAYHAVE FEET
C D
G
F
E
H
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
VOLUTE BASE RINGTAPPED FOR 3”, 125# ANSI FLANGE TO SUPPORT PUMP
e-82SC Standard ConfigurationDIMENSIONS – inches (mm)
MOTORFRAME A B C D
E (max) F G
H (max)
125# ANSIR V(min)J N P
284TC16.00(406)
32.00(813)
21.29(541)
22.83(580)
22.06(560)
13.63(346)
9.25(235)
44.94(1141)
9.50(241)
80.88(22)
14.13(359)
6.00(152)
286TC16.00(406)
32.00(813)
21.29(541)
22.83(580)
23.56(598)
13.63(346)
9.25(235)
46.44(1180)
9.50(241)
80.88(22)
14.13(359)
6.00(152)
324TSC16.00(406)
32.00(813)
21.29(541)
22.83(580)
24.63(626)
13.63(346)
9.25(235)
47.51(1207)
9.50(241)
80.88(22)
15.56(395)
6.00(152)
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
-
31
Dimensions are subject to change. Not to be used for construction purposes unless certified.NOTE: For TEFC add 1-1/2” to dimensions E & H.
e-82SC with Flange SupportDIMENSIONS – inches (mm
MOTORFRAME
HFBOLTING HB
2HEBOLTING HA
HHDIA G
H(max)
284TC33.38(848)
36.88(937)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
45.56(1157)
286TC33.38(848)
36.88(937)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
47.06(1195)
324TSC33.38(848)
36.88(937)
22.50(572)
26.00(660)
1.00(25)
9.88(251)
48.13(1222)
GAUGE TAP
DISCHARGE
DRAIN HOLE1/4” NPT
SUCTION1/4” NPT
GAUGE TAP1/4” NPT
SPACE REQUIREDFOR DISMANTLING
V
A
HB
AHF BOLTING
E
H
G
F
MOTOR MAYHAVE FEET
R R
N – NO. OF HOLESP – DIA. OF HOLESJ – (BOTH FLANGES)
C DHA
2HE BOLTING
HHDIA.
-
32
6 Pole Performance Data
e-82SC 2.5x2.5x7 Standby Operation (1150 RPM)
m ft
m
6.422
7 in 35
35
35
35
0.5 hp
0.33 hp
45 50 5457
59616.5 in
6 in
5.5 in
5 in
20
18
16
14
12
10
8
6
4
4
21
08 16 24 32 40 48 56 64 72 80 88 96 104 112 120
m³/hr
5.6
4.8
3.2
2.4
1.6
0.8
2
1
0
4
HE
AD
NP
SHr
ft
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
62
61
59
57
54
50
45 0.75 hp
US gpm
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
m ft
m
12
44
40
36
32
28
24
20
16
12
10
20
82
5
020 40 60 80 100 120 140 160 180 200 220
m³/hr
10
6
4
4
0
8
HE
AD
NP
SHr
ft
9.5 in 45
45
55
55
62
62
67 70 72
72
70
74
74
74.9
9 in
8.5 in
8 in
7.5 in
7 in
0 4 8 12 16 20 24 28 32 36 40 44 48US gpm
67
67
67
62
62
55
55
2 hp
1.5 hp
1 hp4545
4545 0.75 hp
0.5 hp
e-82SC 2.5x2.5x9.5 Standby Operation (1170 RPM)
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
-
33
m ft
m
1240
36
32
28
24
20
16
12
8
8
0
10
6
4
2
0
8
HE
AD
NP
SHr
ft
20 40 60 80 100 120 140 160 180 200 220 240 260m³/hr0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60
US gpm
9.5 in65 68 71 73
7576
7675
7371
68
65
65
65
3 hp
2 hp
1.5 hp
1 hp
76.8
8.5 in
8 in
9 in
7.5 in
m
m
6.4
5.6
4.8
3.2
2.4
1.6
0.8
2
1
0
4
HE
AD
NP
SHr
ft22
20
18
16
14
12
10
8
6
4
4
21
0
ft
7 in 55
55
55
6570
65
55
1 hp0.75 hp
0.5 hp
0.33 hp
70
72
72
74
74
76
76
76.66.5 in
6 in
5.5 in
5 in
20 40 60 80 100 120 140 160 180 200 220m³/hr0 4 8 12 16 20 24 28 32 36 40 44 48
US gpm
e-82SC 3x3x7 Standby Operation (1180 RPM)
e-82SC 3x3x9.5 Standby Operation (1170 RPM)
6 Pole Performance Data
Not applicable: 1200 RPM — out of DOEregulation scope.
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
Energy Efficiency Ratings:
-
34
m ft
m
16
18
56
48
40
32
24
16
20
40
10
0
14
8
6
4
8
0
12
10
HE
AD
NP
SHr
ft
20 40 60 80 100 120 140 160 180 200 220 240 260m³/hr0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60
US gpm
11 in
10.5 in
10 in
50
50
55
55
50
50
55
55
60
6060
60
64
64
64
64
67
67
67
67
6970
699.5 in
9 in
1.5 hp
2 hp
1 hp
3 hp
5 hp
e-82SC 3x3x11 Standby Operation (1170 RPM)6 Pole Performance Data
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
5 in
m
m
6.4
5.6
4.8
3.2
2.4
1.6
0.8
2
1
0
4
HE
AD
NP
SHr
ft
20
18
16
14
12
10
8
6
4
4
21
0
ft
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340m³/hr0 8 16 24 32 40 48 56 64 72 80
US gpm
7 in
6 in
55
55
55
60 65
55
50
50 1.5 hp
1 hp0.75 hp
0.5 hp
60
65
70
70
72
72
75
75
75.9
6.5 in
6.5 in
e-82SC 4x4x7 Standby Operation (1150 RPM)
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
-
35
HE
AD
m ft
m
12 40
36
32
28
24
20
16
12
8
8
4
43
0
10
6
4
2
2
0
8
NP
SHr
ft
40 80 120 160 200 240 280 320 360 400 440 480m³/hr0 8 2416 32 40 48 56 64 72 80 88 96 104 112
US gpm
8 in
7.5 in
9.5 in55
55
55
55
50
50
5 hp
3 hp
2 hp
1.5 hp
60
60 60
60
65
65
65
65
68
68
71
71
73
73
75
75
76
76
76.4
9 in
8.5 in
e-82SC 4x4x9.5 Standby Operation (1170 RPM)
m ft
m
16
56
48
40
32
24
16
10
20
86
0
14
8
6
4
2
4
0
12
10
HE
AD
NP
SHr
ft
40 80 120 160 200 240 280 320 360 400 440 480m³/hr0 8 2416 32 40 48 56 64 72 80 88 96 104 112
US gpm
11 in
10.5 in
10 in
9.5 in
9 in
55
55
55
55
61
61 61
61
65
65
65
65
68
68
70
71.4
70
2 hp
3 hp
5 hp
7.5 hp
e-82SC 4x4x11 Standby Operation (1170 RPM)
6 Pole Performance Data
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
-
36
e-82SC 6x6x7 Standby Operation
Data coming soon
6 Pole Performance DataH
EA
D
m ft
m
12 40
36
32
28
24
20
16
12
8
20
10
4
1
0
10
6
4
2
4
0
8
NP
SHr
ft
80 160 240 320 400 880 960800640 720480 560m³/hr0 20 6040 80 100 120 140 160 180 200 220
US gpm
9.5 in
9 in
8.5 in
7.5 in
8 in
50
50
59
59
50
7.5 hp
5 hp
3 hp
50
59
59
64
6464
64
68
68
71
71
73
73
74
7474.4
e-82SC 6x6x9.5 Standby Operation (1170 RPM)
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
-
37
m ft
m
16
56
48
40
32
24
16
10
20
8
4
0
14
8
6
4
2
4
0
12
10
HE
AD
NP
SHr
ft
80 160 240 320 400 880 960 1040 1120800720640480 560m³/hr0 20 6040 80 100 120 140 160 180 200 220 240 260
US gpm
11 in62
71
71
71
71
74
74
74
74
76
76
78
78
78.9
67
62 67
62
62
67
67
10.5 in
10 in
9.5 in
9 in
15 hp
10 hp
7.5 hp
5 hp
e-82SC 6x6x11 Standby Operation (1170 RPM)6 Pole Performance Data
Not applicable: 1200 RPM — out of DOEregulation scope.
Energy Efficiency Ratings:
-
38
20 40 60 80 100 120 140 160 180 200m³/hr0 4 8 12 16 20 24 28 32 36 40 44 48
US gpm
m ft
m
14
12
16
48
40
32
24
16
8
10
20
0 0
0
10
6
4
2
4
0
8HEA
DN
PSH
r
ft
7 in
6.5 in
6 in
5.5 in
5 in
40
40
40
40
3 hp
2 hp
1.5 hp1 hp0.75 hp
50
50
50
50
60
60
65
65
68
68
71
71
73.7
4 Pole Performance Data
e-82SC 2.5x2.5x7 Standby Operation (1770 RPM)
m ft
m
28
24
96
88
80
72
64
56
48
40
24
32
20
40
1614
0
20
16
12
8
8
0
HE
AD
NP
SHr
ft
20 40 60 80 100 120 140 160 180 200 220 240 260 280m³/hr0 84 12 16 2420 28 32 36 40 44 5248 56 60 64 68
US gpm
9.5 in
9 in
8.5 in
8 in
7.5 in
7 in
45
45
55
55
61
6161
7.5 hp
5 hp
3 hp61
55
552 hp
1.5 hp
66
66
69
69
66
66
69
69
71
71
71
71
73
73
73
73
74.6
e-82SC 2.5x2.5x9.5 Standby Operation (1780 RPM)
Pump & Motor: PEICL: 0.89 ERCL: 11Pump, Motor & Drive: PEIVL: 0.48 ERVL: 52
Pump & Motor: PEICL: 0.92 ERCL: 8Pump, Motor & Drive: PEIVL: 0.46 ERVL: 54
Energy Efficiency Ratings:
Energy Efficiency Ratings:
-
39
10
m ft
m
14
12
16
48
40
32
24
16
8
20
0 0
0
10
6
4
2
4
0
8HE
AD
NP
SHr
ft
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340m³/hr0 84 12 16 2420 28 32 36 40 44 5248 56 60 64 767268
US gpm
7 in 58
58
67
67
67
67
58
3 hp
2 hp
1 hp1.5 hp
58
71
71
73
73
75
75
76
76
76.96.5 in
6 in
5.5 in
5 in
e-82SC 3x3x7 Standby Operation (1780 RPM)4 Pole Performance Data
m ft
m
28
24
96
88
80
72
64
56
48
40
3032
10
20
0
20
16
12
4
0
HE
AD
NP
SHr
ft
40 80 120 160 200 240 280 320 360 400m³/hr0 8 16 3224 40 48 56 64 72 80 88 96
US gpm
9.5 in
9 in
65
65
70
70
7010 hp
7.5 hp
5 hp3 hp
70
75
7575
75
77
77
79
79
80
80
80.6
8.5 in
8 in
7.5 in
e-82SC 3x3x9.5 Standby Operation (1770 RPM)
Pump & Motor: PEICL: 0.94 ERCL: 6Pump, Motor & Drive: PEIVL: 0.51 ERVL: 49
Pump & Motor: PEICL: 0.94 ERCL: 6Pump, Motor & Drive: PEIVL: 0.47 ERVL: 53
Energy Efficiency Ratings:
Energy Efficiency Ratings:
-
40
4 Pole Performance Data
m ft
m
40
32
28
36
140
130
120
110
100
90
80
70
60
50
40
30
20
40
24
20
16
12
8
0
HE
AD
NP
SHr
ft
40 6020 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360m³/hr0 8 16 3224 40 48 56 64 72 80
US gpm0
11 in50
50
55
55
55
55
50
5 hp
7.5 hp
10 hp
15 hp
50
60
6060
60
64
64
64
64
67
67
67
69
69
70
70
70.5
10 in
10.5 in
9.5 in
9 in
e-82SC 3x3x11 Standby Operation (1770 RPM)
m ft
m
14
12
16
48
40
32
24
16
8
20
0 0
0
10
6
4
2
8
0
8
HE
AD
NP
SHr
ft
7 in 55
55
60
60
65 70 7376
78
55
5 hp3 hp
2 hp1.5 hp
55
60
60
65
7073
76
78
78.86.5 in
6 in
5.5 in
5 in
40 80 120 160 280200 320240 360 440400 520 560m³/hr0 8 16 24 484032 56 64 8072 88 96 104 112 128120
US gpm480
e-82SC 4x4x7 Standby Operation (1750 RPM)
Pump & Motor: PEICL: 0.95 ERCL: 5Pump, Motor & Drive: PEIVL: 0.48 ERVL: 52
Pump & Motor: PEICL: 0.97 ERCL: 3Pump, Motor & Drive: PEIVL: 0.51 ERVL: 49
Energy Efficiency Ratings:
Energy Efficiency Ratings:
-
41
m ft
m
28
24
96
88
80
72
64
48
56
40
32
24
16
6
10
20
0
20
16
12
8
4
4
9.5 in
9 in
6973
73
73
73
69
69
64
64
59
59
54
15 hp10 hp
7.5 hp
5 hp
54
75
75
77
77
78
78
78.9
69
8.5 in
8 in
7.5 in
0
HE
AD
NP
SHr
ft
40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 800m³/hr0 10 20 30 5040 60 70 80 90 100 110 120 130 140 150 160 170 180
US gpm
e-82SC 4x4x9.5 Standby Operation (1770 RPM)
m ft
m
36
40
28
32100
110
120
130
80
90
70
60
50
40
30
22.5
20
0
24
16
20
12
8
10
0
HE
AD
NP
SHr
ft
11 in
6467
70
70
72
72
73
73
73.5
60
6467
60 64
64
67
67
70
70
60
60
55
20 hp
15 hp
10 hp
7.5 hp
55
10.5 in
9.5 in
10 in
9 in
40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720m³/hr0 2010 30 6040 50 70 80 10090 110 130120 140 150 160 170
US gpm
e-82SC 4x4x11 Standby Operation (1770 RPM)
4 Pole Performance Data
Pump & Motor: PEICL: 0.95 ERCL: 5Pump, Motor & Drive: PEIVL: 0.47 ERVL: 53
Pump & Motor: PEICL: 0.96 ERCL: 4Pump, Motor & Drive: PEIVL: 0.47 ERVL: 53
Energy Efficiency Ratings:
Energy Efficiency Ratings:
-
42
e-82SC 6x6x7 Standby Operation
m ft
m
24
28
16
20 64
72
80
88
48
56
40
32
24
16
84
20
0
8
12
4
10
0
HE
AD
NP
SHr
ft
9.5 in
9 in
50
50
60
60
65
6560
50
5025 hp
20 hp15 hp
10 hp
60
65
65
69
69
69
69
72
72
74
74
74.68.5 in
8 in
7.5 in
80 160 240 320 400 480 560 640 720 800 880 960 1040 1120 1200 1280 1360 1440 1520m³/hr0 20 40 60 12080 100 140 160 180 200 220 240 260 300280 340320 360
US gpm
e-82SC 6x6x9.5 Standby Operation (1770 RPM)
Data coming soon
4 Pole Performance Data
Pump & Motor: PEICL: 0.99 ERCL: 1Pump, Motor & Drive: PEIVL: 0.48 ERVL: 52
Energy Efficiency Ratings:
-
43
m ft
m
40
36
32100
120
80
60
40
20
5
20
0
24
28
20
12
16
8
4
4
8
0
HE
AD
NP
SHr
ft
11 in69 73
76 78
78
80
80
80.5
63
10.5 in
10 in
9 in
9.5 in
69
73
76
63
40 hp
30 hp
25 hp
20 hp
15 hp
76
7369
63
73 766963
80 160 240 320 400 480 560 640 720 800 880 960 1040 1120 1200 1280 1360 1440 1520m³/hr0 20 40 60 10080 120 140 160 180 200 220 240 260 280 300 320 340 360
US gpm
e-82SC 6x6x11 Standby Operation (1770 RPM)4 Pole Performance Data
Pump & Motor: PEICL: 0.97 ERCL: 3Pump, Motor & Drive: PEIVL: 0.48 ERVL: 52
Energy Efficiency Ratings:
-
44
m ft
m
64
56
100
120
140
160
180
200
80
60
40
20
5
0
40
48
32
24
16
8
2080
0
HEA
DN
PSH
r
ft
7 in
6.5 in
6 in
5 in
5.5 in
0 m³/hrUS gpm40 80 120 160 200 240 280 320 360
8 16 24 32 40 48 56 64 72 80 88400
96
40 50 60 65 6871
73.7
71 6865
40 20 hp
15 hp
10 hp7.5 hp
5 hp
50
60
40 50
40
50
2 Pole Performance Data
e-82SC 2.5x2.5x7 Standby Operation (3550 RPM)
m ft
m
120
200
240
280
320
360
400
160
120
8060
0
100
80
20
60
8
40
20
80
160
0
HE
AD
NP
SHr
ft
9.5 in
9 in
8.5 in
7.5 in
7 in45 55 61
6971
73
73
73
74.6
66
45 55 6169 71
66
8 in
55
55
61
6971
66
73
61
6971
66
20 hp
10 hp
15 hp25 hp
30 hp
40 hp
50 hp
60 hp
0 m³/hr40 80 160120 240200 280 320 360 400 480440 5208 16 24 32 40 48 56 64 72 80 88 96 112104 120 128
560 600136
US gpm
e-82SC 2.5x2.5x9.5 Standby Operation (3550 RPM)
Pump & Motor: PEICL: 0.89 ERCL: 11Pump, Motor & Drive: PEIVL: 0.45 ERVL: 55
Energy Efficiency Ratings:
Pump & Motor: PEICL: 0.94 ERCL: 6Pump, Motor & Drive: PEIVL: 0.50 ERVL: 50
Energy Efficiency Ratings:
-
45
m ft
m
56
100
120
140
160
180
200
80
60
40
2010
0
40
48
32
24
16
8
20
10 40
0
HE
AD
NP
SHr
ft
0 m³/hr40 80 160120 240200 280 320 360 400 480440 5208 16 24 32 40 48 56 64 72 80 88 96 112104 120 128
560 600 640136 144
US gpm
7 in
6.5 in
6 in
5.5 in
55
55
65
65
70 70 7476
77 77.2
7776
7472
70
65
65
55
55
25 hp
20 hp
15 hp
10 hp7.5 hp
5 in
e-82SC 3x3x7 Standby Operation (3550 RPM)2 Pole Performance Data
Pump & Motor: PEICL: 0.90 ERCL: 10Pump, Motor & Drive: PEIVL: 0.45 ERVL: 55
Energy Efficiency Ratings:
m ft
m
56
100
120
140
160
180
200
80
60
40
20
5
40
48
32
24
16
8
2080
0
HE
AD
NP
SHr
ft
0 m³/hr80 160 240 400320 480 560 640 800720 88020 40 60 80 100 120 140 160 200180 220
960 1040 1120240 260
US gpm
7 in60
60
40 hp30 hp
25 hp20 hp
15 hp
60
60
65
65
70
70
73
73
75
75
77
77
78
78
78.76.5 in
6 in
5.5 in
5 in
0
e-82SC 4x4x7 Standby Operation (3550 RPM)
Pump & Motor: PEICL: 0.96 ERCL: 4Pump, Motor & Drive: PEIVL: 0.48 ERVL: 52
Energy Efficiency Ratings:
-
46
e-82SC 6x6x7 Standby Operation
Data coming soon
2 Pole Performance Data
-
47
Useful Pump Formulas
Affinity Laws: Effect of varying speed or impeller diameter.
Head (Feet) x Specific Gravity2.31
Pressure (PSI) x 2.31Specific Gravity
Dynamic Suction Lift (Feet) x .883 x Specific Gravity
GPM x Head (Feet) x Specific Gravity3960 x Pump Efficiency
GPM x Head (Feet) x Specific Gravity3960
Horsepower (Water)Horsepower (Brake)
x 100%
Positive Factors - Negative Factors
Pressure (PSI) =
Head (Feet) =
Vacuum (in. of Mercury) =
Horsepower (Brake) =
Horsepower (Water) =
Efficiency (Pump) =
NPSH (Available) =
GPM Capacity Head (Feet) BHP
ImpellerDiameterChange
Q2=D2D1
x Q1 H2=D2D1
2
x H1 P2=D2D1
3
x P 1
SpeedChange H2=
RPM 2RPM 1
2
x H1 P2=RPM 2RPM 1
3
x P 1
Where Q = GPM, H = Head, P = BHP, D = Impeller Diameter, RPM = Pump Speed
Q2=RPM 2RPM 1
x Q1
-
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries.© 2021 Xylem Inc. B-Curve-e-82SC January 2021
Xylem Inc. 8200 N. Austin AvenueMorton Grove, Illinois 60053Phone: (847) 966-3700Fax: (847) 965-8379www.xylem.com/bellgossett
We value your feedback. Please take our 3 question survey at bellgossett.com/survey to let us know how we are doing.
1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.
We’re a global team unified in a common purpose: creating advanced technology solutions to the world’s water challenges. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. Our products and services move, treat, analyze, monitor and return water to the environment, in public utility, industrial, residential and commercial building services settings. Xylem also provides a leading portfolio of smart metering, network technologies and advanced analytics solutions for water, electric and gas utilities. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise with a strong focus on developing comprehensive, sustainable solutions.
For more information on how Xylem can help you, go to www.xylem.com
Xylem