Separation Science - Dongmyungdongmyung.co.kr › pds_home › broch › b489k.pdfAlltech...

16
Separation Science TODAY a newsletter for today’s chromatographer © Copyright 2004 Alltech Associates, Inc. UNP Specialists in Chromatography Specialists in Chromatography SST VOLUME 4 brochure #489K Page 12 & 15 INSIDE INDUSTRY FOCUS: Pharmaceutical Pages ............................... 9 General Interest Pages ............................. 13 PRODUCT INFO: HPLC/IC Pages .................... 3-11, 16 GC Pages ........................ 12-14 Sample Handling Pages ........................ 14-15

Transcript of Separation Science - Dongmyungdongmyung.co.kr › pds_home › broch › b489k.pdfAlltech...

  • Separation ScienceTODAY

    a newsletter for today’s chromatographer

    © Copyright 2004 Alltech Associates, Inc. UNP

    Specialists in ChromatographySpecialists in Chromatography

    SST VOLUME 4 brochure #489K

    Page 12 & 15

    I N S I D E

    INDUSTRY FOCUS:PharmaceuticalPages ............................... 9

    General InterestPages ............................. 13

    PRODUCT INFO:HPLC/ICPages .................... 3-11, 16

    GCPages ........................ 12-14

    Sample HandlingPages ........................ 14-15

  • 2

    INDUSTRY FOCUSPharmaceuticalSeparation of a Dissimilar Complex Antibiotic Pair Using

    a New Reversed-Phase HPLC Column and ELSD 9

    General InterestOnsite Generation of Fuel Gases for Flame

    Ionization GC Detectors 13

    HPLC/ICNew! Alltima™ HP HPLC ColumnsHigh performance from high purity silica 3

    Alltima HP HPLC Column Applications 4

    ProSphere™ HPLC ColumnsHPLC columns for the life science industry 5

    Astec CHIROBIOTIC™ HPLC ColumnsSimplify your most challenging chiral separations 6

    Alltech's Method Development Assistant SoftwareMeet your new assistant 7

    Alltech Degassing SystemsThe most advanced degassing technology 8

    Model 2000 and Model 800 ELSDSensitive, universal HPLC detection 8

    Ion Chromatography Starter KitsSave money with starter kits 10

    New! Ion SuppressorsOutlast and outperform membrane suppressors 11

    SofGrip™ HPLC FittingsThe toughest fitting with the softest grip 16

    GCNew! Parker Balston® Model FID-1000 Gas StationHydrogen and zero air from one gas generator 12

    Alltech Indicating Hydrocarbon TrapSee for yourself - the only indicating hydrocarbon traps 12

    Alltech Digital Flow Check™ Mass FlowmetersA better way to measure gas flow 14

    SAMPLE HANDLINGDrug-Clean™ SPE ColumnsGet more accurate drug analysis results 14

    Autosampler VialsTake advantage of our special pricing 15

    In This Issue:

  • 3www.dongmyung.co.kr

    New! High performance from high purity silica

    Degassing Systems SpecificationsPhase Particle Size Carbon Loading Pore Size Surface Area End Capped Position

    C18 3 and 5µm 12% 190Å 200m2/g Yes Most popular phase

    C8 3 and 5µm 8% 190Å 200m2/g Yes Faster peak elution

    C18 HiLoad 3 and 5µm 24% 100Å 450m2/g Yes More retentive for diffi cult separations

    EPS C18 3 and 5µm 4% 190Å 200m2/g No Unique polar selectivity

    C18 Amide 3 and 5µm 12% 190Å 200m2/g Yes Low bleed MS applications: 100% aqueous

    compatibility

    Cyano 3 and 5µm 4% 190Å 200m2/g Yes Unique retention and stability

    Silica 3 and 5µm - 100Å 450m2/g No Normal phase

    AlltimaTM HP HPLC ColumnsC18 C18 EPS

    PARTICLE C18 C8 HiLoad Amide C18 Cyano SilicaSIZE LENGTH X ID PART NO. PART NO. PART NO. PART NO. PART NO. PART NO. PART NO.

    Analytical 3µm 100 x 4.6mm 87667 87739 87685 87721 87703 87757 877853µm 100 x 2.1mm 87669 87741 87687 87723 87705 87759 87787

    3µm 150 x 4.6mm 87668 87740 87686 87722 87704 87758 87786

    3µm 150 x 2.1mm 87670 87742 87688 87724 87706 87760 87788

    5µm 150 x 4.6mm 87679 87751 87697 87733 87715 87769 87797

    5µm 150 x 2.1mm 87681 87753 87699 87735 87717 87781 87799

    5µm 250 x 4.6mm 87680 87752 87698 87734 87716 87780 87798

    5µm 250 x 2.1mm 87682 87754 87700 87736 87718 87782 87802

    Rocket™ 3µm 33 x 7mm 87671 87743 87689 87725 87707 87761 877893µm 53 x 7mm 87672 87744 87690 87726 87708 87762 87790

    Expedite™ 3µm 10 x 2.1mm 87673 87745 87691 87727 87709 87763 877913µm 10 x 4.6mm 87675 87747 87693 87729 87711 87765 87793

    3µm 20 x 2.1mm 87674 87746 87692 87728 87710 87764 87792

    3µm 20 x 4.6mm 87676 87748 87694 87730 87712 87766 87794

  • 4

    Alltima HP Application

    Peak Identification1. Methionine Enkephalin2. Leucine Enkephalin3. Angiotensin II4. Neurotensin5. Angiotensin I6. Substance P

    Peptide Mix

    Column: Alltima HP C18, 5µ, 250 x 4.6mm Mobile Phase: A: 0.1% TFA in water / B: 0.08% TFA in

    acetonitrile Gradient: (Time,%B),(0,20),(20,40) Flow Rate: 1.0mL/min Detector: UV at 220nm

    10369

    Peak Identification1. Desipramine (0.05 mg/mL)2. Nortriptyline (0.05 mg/mL)3. Diphenhydramine (0.25 mg/mL)4. Amitriptyline (0.05 mg/mL)

    Tricyclic Antidepressants

    Column: Alltima HP C8, 5µ, 150 x 4.6mm Mobile Phase: A: 25mM Phosphate Buffer pH7 / B: Methanol Gradient: (Time,%B),(0,60),(8,75),(20,75) Flow Rate: 1.0mL/min Detector: UV at 254nm

    10373

    Peak Identification1. Sulfanilamide2. Sulfamerazine3. Sulfamethazine4. Sulfamethizole

    Sulfa Drugs

    Column: Alltima HP C18 HiLoad, 5µ, 150 x 4.6mm Mobile Phase: (85:15) 0.1% phosphoric acid:acetonitrile Flow Rate: 1 mL/min Detector: UV at 254nm

    10351

    Peak Identification1. Ethotoin2. Phenytoin3. Mephenytoin4. Carbamazepine

    Anticonvulsants

    Column: Alltima HP C18 HiLoad, 5µ, 150 x 4.6mm Mobile Phase: (70:30) 25mM ammonium acetate:acetonitrile Flow Rate: 1 mL/min Detector: ELSD

    10349

    Peak Identification1. Cytidine2. Uridine3. Xanthosine4. Guanosine5. Adenosine

    Nucleosides

    Column: Alltima HP EPS C18, 5µ, 150 x 4.6mm Mobile Phase: A: 0.03M potassium phosphate, pH3.2 /

    B: acetonitrile Gradient: (Time,%B),(0,5),(2,5),(20,30) Flow Rate: 1 mL/min Detector: UV at 260nm

    10347

    Peak Identification1. Nortriptyline2. Diphenhydramine3. Amitriptyline

    Basic Drugs

    Column: Alltima HP C18 HiLoad, 5µ, 150 x 4.6mm Mobile Phase: (85:15) methanol:25mM potassium phosphate pH 7 Flow Rate: 1mL/min Detector: UV at 254nm

    10352

  • 5www.dongmyung.co.kr

    Alltech ProSphere™ HPLC Columns

    Other column dimensions are available. Visit our web store at www.alltechWEB.com or call your local Alltech office.i

    ProsphereTM HPLC ColumnsDESCRIPTION LENGTH X ID PART NO.

    ProsphereTM C18 150 x 150µm 32904300Å 250 x 150µm 329055µm 150 x 300µm 32907

    250 x 300µm 32908

    150 x 2.1mm 35098

    150 x 4.6mm 32969

    250 x 4.6mm 32971

    ProsphereTM C4 150 x 150µm 33904300Å 250 x 150µm 339055µm 150 x 300µm 33907

    250 x 300µm 33908

    150 x 2.1mm 35096

    150 x 4.6mm 33989

    250 x 4.6mm 33991

    ProsphereTM C18 150 x 150µm 35504100Å 250 x 150µm 355055µm 150 x 300µm 35507

    250 x 300µm 35508

    150 x 2.1mm 35090

    150 x 4.6mm 35091

    250 x 4.6mm 35087

    Request a FREE copy of our new ProSphereTM Life Science Catalog

    Introducing a full line of Size Exclusion, Ion Exchange, Affinity, Hydrophobic Interaction,and Reversed-Phase Chromatography Columns. To receive a catalog, use the insert,request on-line at www.alltechWEB.com, or call 1-800-ALLTECH.

  • 6

    For additional information on chiral separations, visit our online technical library at www.alltechWEB.com.i

    Separation of Metoprolol on CHIROBIOTICTM T

    Separation of Bupivacaine on CHIROBIOTICTM V

    Methanol with Ammonium Trifl uoroacetate at 0.1% by weight1.0mL/min

    Methanol with Ammonium Trifl uoroacetate at 0.1% by weight1.0mL/min

    Astec CHIROBIOTIC™ HPLC Columns

    CHIROBIOTICTM V: amines; including cyclic and tertiary amines, esters, neutral molecules and profens

    CHIROBIOTICTM T: -halogenated aliphatic acids, amino acids, beta-blockers, carboxylic acids, cyclic aromatics, neutral aromatics, and small peptides

    CHIROBIOTICTM R: -hydroxy acids, anionic molecules, aromatic esters, alcohols, di- and tri-peptides, and substituted -halogenated acids

    CHIROBIOTICTM TAG: amino acids, beta-amino acids, carnitine, courmarins, diazopines, hydantoins, oxazolidinones, phosphonates, small peptides, and sulfoxides

    FREEChiral MethodDevelopment

    Wall Chart with Purchase!

    Use Promo Code SP035

    Peak 1 - 15.4min.Peak 2 - 17.1min.

    Peak 1 - 5.6min.Peak 2 - 6.2min.

    Astec CHIROBIOTICTM HPLC ColumnsCHIROBIOTICTM V CHIROBIOTICTM T CHIROBIOTICTM R CHIROBIOTICTM TAG

    LENGTH X ID PART NO. PART NO. PART NO. PART NO.

    100 x 4.6mm 11022AC 12022AC 13022AC 14022AC

    150 x 4.6mm 11023 12051 12516 14023AC

    250 x 4.6mm 11024 12053 12518 14024AC

    Guards Cartridge, 20 x 4.0mm 11019 12445 12522 14100AC

    Holder 11014 11014 11014 11014

  • 7www.dongmyung.co.kr

    New! Alltech’s Method Development Assistant Software

    Your Assistant Helps Develop New Methods

    Column kit includes:

    150 x 4.6mm, 5µm columns from our premium, and best selling product lines.- PrevailTM C18- PrevailTM Select C18- AlltimaTM HP EPS- AlltimaTM HP C18 HiLoad- AlltimaTM HP Amide

    FREE Column Kit!

    Your Assistant Gets Existing Methods to Work

    Meet Your New Assistant . . .

    Method Development ToolsDESCRIPTION PART NO. PRICE

    Method Development ToolsAnalytical Column Kit 22345 2500

    Software Alone 22348 3118.75

    Software and FREE Column Kit 22347 3118.75

    For more information on Alltech's MDATM, visit our online technicallibrary or call for a demo or quote.i

  • 8

    Degassing Systems and ELSDsLC Instruments to Address Specific Needs and Budgets

    The most advanced degassing technology

    Alltech On-line Degassing Systems offer:

    Sensitive, universal HPLC detection

    Model 2000 ELSD Model 800 ELSD

    For information on the ELSDs, visit our online technical library, or call and request brochures 474 and 475.For information on the Degassing Systems, visit our online technical library, or call and request brochure 479.i

  • Separation of a Dissimilar Complex Antibiotic Pair Using a New Highly Versatile Reversed-Phase HPLC Column and ELSDRomulus Gaita and Dr. Cary Thrall, [email protected]

    Industry Focus - HPLCpharmaceutical

    9www.dongmyung.co.kr

    See page 8 for ELSD information. For information on PrevailTM Select C18, visit our online technical library at www.alltechWEB.com, or call and request document M076.i

    1. Tylosin2. Monensin

    Figure 2

    Column: PrevailTM Select C18, 5µm, 150 x 4.6mm (Part No. 99300)

    Mobile Phase: 95:5 Acetonitrile:Wateradjusted to pH 9 w/NH4OH

    Flowrate: 1.0mL/minDetector: ELSD 2000 N2 Flow: 2.5L/min Drift Tube: 75°C, Impactor Off

    Figure 1a - Monensin

    Figure 1b - Tylosin

    Figure 3

  • 10

    Ion Chromatography Starter Kits

    U.S. EPA Methods Anion Column Kit - for EPA Methods 300.0, 300.1, 317.0. and 326.0

    Includes a NovosepTM A-2 Column (250 x 4.0mm), guard cartridges, a 3.6mM carbonate EZ-LUTETM Concentrate, and anion and oxyhalide standards.

    Suppressor-Based Anion Column Kit - for analysis of anions by suppressor-based methods

    Includes a NovosepTM A-1 Column (150 x 4.6mm), guard cartridges, a 1.7mM/1.8mM bicarbonate/carbonate EZ-LUTETM Concentrate, and anion standards.

    Non-Suppressed Anion Column Kit - for analysis of anions by non-suppressed methodsIncludes an AllsepTM Anion Column (100 x 4.6mm), guard cartridges, a 4mM pHBA EZ-LUTETM Concentrate, and anion standards.

    Mono- and Divalent Cation Column Kit - for simultaneous analysis of mono- and divalent cations

    Includes a Universal Cation Column (100 x 4.6mm), guard cartridges, a 3mM methanesulfonic acid EZ-LUTETM Concentrate, and cation standards.

    IC Accessory Kit - tools and accessories for every IC systemIncludes PEEK tubing, one-piece fi ttings, a PEEK union, two different size plastic syringes, a luer-hub needle, tubing cutter, wrench, and two different in-line solvent fi lters.

    Request a FREE copy of our new Ion Chromatography brochure

    Alltech’s new Ion Chromatography Brochure includes all the products you need toperform high-quality ion chromatography separations. Learn about our new UniversalCation HR Columns and our new low-cost, high-sensitivity suppressors. Browse ourcomplete line of IC standards, including new standards for amines and organic acids.Choose Alltech for your IC needs, and receive the friendly, helpful customer support youexpect and deserve. To receive a brochure, use the insert, request on-line atwww.alltechWEB.com, or call 1-800-ALLTECH .

    IC Starter KitsDESCRIPTION PART NO.

    U.S. EPA Methods Anion Column Kit 270107

    Suppressor-Based Anion Column Kit 270106

    Non-Suppressed Anion Column Kit 270102

    Mono- and Divalent Cation Column Kit 269105

    IC Accessory Kit 269101

    Kit includes a collection of tubing, fi ttings, and other

    hardware.

    Kits include an analyticalcolumn, guard columns,buffer concentrate, and

    standards.

    Accessory Kit Column Kits

  • 11www.dongmyung.co.kr

    New! IC Suppressors

    Alltech SuppressorsDESCRIPTION CAPACITY PART NO.

    Model 640 Suppressor (Isocratic)120V 20mN Sodium 640100

    240V 20mN Sodium 640200

    Model 641 Suppressor (High Sensitivity and Gradient)120V 40mN Sodium 641100

    240V 40mN Sodium 641200

    For information on the Alltech Suppressors, visit ouronline technical library at www.alltechWEB.com, orcall and request brochure 484.i

    1. Methionine Enkephalin2. Leucine Enkephalin

    1. Methionine Enkephalin2. Leucine Enkephalin

    Peptide Mix

    Peptide Mix

    Peptide Mix

    Column: Alltima HP C18, 5µ, 250 x 4.6mm Mobile Phase: A: 0.1% TFA in water / B: 0.08% TFA in

    acetonitrile Gradient: (Time,%B),(0,20),(20,40) Flow Rate: 1.0mL/min Detector: UV at 220nm

    9290

    9291

    Only Alltech’s suppressors degas the effl uent for high sensitivity,stable baselines, and better resolving power.

    * U.S. patent numbers 6,444,475; 6,468,804

  • 12

    AT™-Indicating Hydrocarbon Traps AT™-Indicating Hydrocarbon In-Line Trap

    AT™-Indicating HydrocarbonCartridge Trap

    AT™-Indicating Hydrocarbon TrapsDESCRIPTION PART NO.

    In-Line Trap, 1/8" fittings 7210

    In-Line Trap, 1/4" fittings 7212

    Cartridge Trap (requires baseplate) 81017

    Cartridge Baseplate 81025

    New! Parker Balston Model FID-1000 Gas Station

    Model FID-1000 Gas Station SpecificationsGAS PRESSURE PURITY FLOW

    Hydrogen: 0-90psig 99.9995% 90cc/min

    Zero Air: 0-60psig

  • 13www.dongmyung.co.kr

    Onsite Generation of Fuel Gases for Flame Ionization GC DetectorsReggie Bartram, [email protected]

    Abstract

    Introduction

    Conclusion

    References1. Compressed Gas Association, Inc. Handbook

    of compressed gases, New York: Van Nostrand Reinhold Co., 1981

    2. Robert Daly, The Shift to On-Site Gas Generation, American EnvironmentalLaboratory, March 1995

    3. Air Products and Chemicals, Inc. Safety-gram-14. Don’t turn a cylinder into a rocket: 1988.

    4. Albert A, et al. What happens to gas cylinder purity as content is consumed? IEEE/SEMI Advanced Semiconductor Manufacturing Conference, 1993, Boston, MA

    Industry Focus - GC

    Baseline Comparison

    general interest

  • 14

    Alltech Digital Flow Check™ Mass Flowmeters

    New! Mixed-Mode Drug-Clean™ SPE ColumnsGet more accurate drug analysisresults

    Model DFC-HRTM

    Digital Flow CheckTM Flowmeters Specifi cationsFlow range: DFCTM 0.1-500 SCCM (except CO2 to 300 SCCM)

    DFC-HRTM 0.01-500 SCCM (except CO2 to 300 SCCM)

    Accuracy: +/-2% of reading Display: 16-character alphanumeric LCD, autoranging

    Display modes: mass fl ow, split ratio, linear velocity (std. fl ow range)

    Power: 9V alkaline battery (included), auto-off function,

    low battery warning

    Dimensions: 190.5 x 57.4 x 101.6mm (7.5" x 2.26" x 4.0")

    For a complete list of drug standards,visit our online technical library atwww.alltechWEB.com.i

    Digital Flow CheckTM FlowmetersMODEL PART NO.

    DFCTM 4700

    DFC-HRTM 5700

    Mixed Mode Drug-CleanTM ColumnsDESCRIPTION QTY PART NO.

    200mg/4mL 50 207010

    Cocaine and Benzoylecgonine Extract from Urine

    1. Cocaine (2.5 mg/ml) 2. Benzoylecgonine-TMS,

    Benzoylecgonine-d3-TMS (5.0mg/mL)

    Column: Helifl ex® AT-5ms, 30m x 0.25mm x 0.25µm (Part No. 15807)

    Temp: 225°C (0 min hold) to 315°C (11 min hold) at 10°C/min

    Carrier: Helium at 0.8mL/min (28cm/sec)

    Detector: MSD at 325°C

    2656

  • 15www.dongmyung.co.kr

    Alltech Autosampler Vials

    Convenience Kits Ordering InformationLINER DESCRIPTION TFE/BUTYL LINER TFE/SILICONE LINER TFE/SILICONE/TFE LINER

    VIAL AND CLOSURE DESCRIPTION KIT PART NO. KIT PART NO. KIT PART NO.

    12x32mm Crimp Style Vials, 11mm SealsStandard Mouth Crimp Vials, Aluminum Seals 95161 98318 98373

    WIDE Mouth Crimp Vials, Aluminum Seals 98397 98419 98447

    Snap Seal Vials, Clear Poly CrimpTM Seals 88487 88496 88494

    12x32mm Clear Screw Thread VialsStandard Mouth Vials, 8/425 Black Cap 98380* 89074 89078

    WIDE Mouth Vials, 10/425 Black Cap 97243 97239 97252

    Robotic R.A.M.TM‚ Vials, 9mm Black Cap 89135 89145 89149

    * Preassembled kits only

    For more information on vials, visit our online technical library at www.alltechWEB.com, or call and request brochure 445.i

    Screw Thread Vials and Caps

    Kits contain: Unassembled, 100 each Clear Glass Vials, Caps with Liners

    Crimp Vials with Aluminum Seals Snap Seal Vials with Poly CrimpTM Seals

    Q:

    A:

  • SofGrip™ HPLC Fittings

    www.alltechWEB.com

    01/0

    4 #

    489K

    © Copyright 2003 Alltech Associates, Inc.Alltech reserves the right to change prices and/or specifications without prior notification.

    Use of Our Products: Alltech Associates, Inc., supplies chromatographic equipment reagents and accessories for non-medical

    laboratory use only. This means our products: ... may NOT be used as drugs, ...may NOT be used as cosmetics, ...may NOT be

    used as medical devices or as in vitro diagnostic devices.

    Printed in the USA.

    SofGripTM One-Piece FittingsSTANDARD NO-SLIPTM

    COLOR QTY PART NO. PART NO.

    Black, Short 10 40501 40511

    Black, Long 10 40506 40516

    Red, Short 10 40502 40512

    Blue, Short 10 40503 40513

    Green, Short 10 40504 40514

    Yellow, Short 10 40505 40515

    Assortment, Short 10 40507 40517

    OtherFittings

    No-SlipTM

    Fitting

    The trademarks referred to herein are the property of their respective owners.