Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

28
Seismic Design of Seismic Design of Buried Structures Buried Structures Doug Jenkins Doug Jenkins Interactive Design Services Interactive Design Services

Transcript of Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Page 1: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Seismic Design of Buried Seismic Design of Buried StructuresStructures

Doug JenkinsDoug JenkinsInteractive Design ServicesInteractive Design Services

Page 2: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Why Bother?Why Bother?

"Results show that the bending moments in the arch from horizontal earthquake loading can be significant in relation to the gravity load actions. These moments are also very sensitive to the backfill and surrounding soil stiffness properties and rather less sensitive to the foundation soils beneath the arch.”

John Wood

Page 3: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Collapse of buried structure in JapanCollapse of buried structure in Japan

Spec

Possible earthquake related failure south of Sydney Consequences of failure

Page 4: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Seismic design provisions in AS5100Seismic design provisions in AS5100

Specific rules are given for the categorisation of bridges. A formula is given for the fundamental period of bridge

structures (for use in category BEDC-1 designs only). Specific structural response factors are given for bridges of

different types. Structural detailing requirements relevant to bridges are

given.

Page 5: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Problems with application to buried Problems with application to buried structuresstructures

The requirements for more detailed analysis methods are related to bridge span, and may not be relevant to buried structures.

Vertical earthquake effects may be important for buried structures, but only horizontal effects are required to be considered for almost all buried structures.

The formula for the fundamental period is not applicable to buried structures.

For static analysis the earthquake design force is not applicable to buried structures.

The appropriate response modification factor is not clear.

Page 6: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Buried arch design studyBuried arch design study

Geraldton Southern Transport Corridor

14.5 m span x8 m high 3m and 15 m cover Acceleration 0.10g Site factor 1.5 Bridge Type II

Page 7: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

ClassificationClassification

Type III - Bridges and associated structures that are essential to post-earthquake recovery, as determined by the relevant authority.

Type II - Bridges that are designed to carry large volumes of traffic or bridges over other roadways, railways or buildings.

Type I - Bridges not of Type II or Type III.

Page 8: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

ClassificationClassification

Bridge classification Product of acceleration coefficient and site

factor Type III Type II Type I

aS ≥ 0.2

BEDC-4 BEDC-3 BEDC-2

0.1 ≤ aS < 0.2

BEDC-3 BEDC-2 BEDC-1

aS < 0.1

BEDC-2 BEDC-1 BEDC-1

Page 9: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

ClassificationClassification BEDC-1

– < 20 m span, no earthquake analysis

– > 20 m span, static analysis, horizontal forces

BEDC-2– Static or dynamic analysis

– > 35 m span, horizontal and vertical

BEDC-3– Static analysis only if a single dominant mode

– Consider horizontal and vertical loads

BEDC-4– Dynamic analysis; horizontal and vertical

Page 10: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Buried arch design studyBuried arch design study

For each fill height (3m and 15 m):– Natural frequency analysis– Deflection under unit horizontal acceleration– Pseudo-static analysis– Response Spectrum analysis– Push-over analysis

Page 11: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Buried arch design studyBuried arch design study For each of the analyses the following

material stiffness properties were used:

– Typical soil and uncracked concrete.

– Soil stiffness reduced by half and uncracked concrete.

– Soil stiffness reduced by half, and concrete moment-curvature relationship (static analyses), or cracked stiffness (response spectrum analyses)

A total of 26 separate analyses were carried out.

Page 12: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Typical Finite Element MeshTypical Finite Element Mesh

Page 13: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Mesh DetailMesh Detail

Page 14: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

3 metres cover Period, T 0.055 0.5 Stat T /Dyn T C

Elastic 0.605 119 0.600 99.1% 0.261 Reduced soil 0.850 231 0.836 98.4% 0.209 Reduced both 0.853 233 0.840 98.4% 0.208

15 metres cover Elastic 0.999 341 1.016 101.7% 0.188 Reduced soil 1.405 679 1.433 102.0% 0.149 Reduced both 1.408 680 1.434 101.8% 0.149

Fundamental period, Static Fundamental period, Static Design Force CoefficientDesign Force Coefficient

Page 15: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Static analysis, 3m CoverStatic analysis, 3m Cover

-200

-150

-100

-50

0

50

100

150

200

0.0 5.0 10.0 15.0 20.0 25.0

Distance around arch, m

Ben

din

g M

om

ent,

kN

m

Standard stiffness Reduced soil stiffness Reduced soil and beam stiff

Page 16: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Dynamic Analysis, 3m CoverDynamic Analysis, 3m Cover

-250

-200

-150

-100

-50

0

50

100

150

200

250

0.0 5.0 10.0 15.0 20.0 25.0

Distance around arch, m

Ben

din

g M

om

ent,

kN

m

Dynamic Lin Dyn, reduced soil stiffness Dyn, reduced soil&beam stiff

Page 17: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Maximum Moments, 3m CoverMaximum Moments, 3m Cover

-250

-200

-150

-100

-50

0

50

100

150

200

250

Standard Stiffness Reduced Soil Stiffness Reduced Soil and Beam

Ben

din

g M

om

ent,

kN

m

Pseudo-Static, +ve Resp. Spect. +ve Pseudo-Static, -ve Resp. Spect. -ve

Page 18: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Static analysis, 15m CoverStatic analysis, 15m Cover

-250

-200

-150

-100

-50

0

50

100

150

200

0.0 5.0 10.0 15.0 20.0 25.0

Distance around arch, m

Ben

din

g M

om

ent,

kN

m

Standard Reduced soil stiffness Reduced soil and beam stiff

Page 19: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Dynamic Analysis, 15m CoverDynamic Analysis, 15m Cover

-250

-200

-150

-100

-50

0

50

100

150

200

250

0.0 5.0 10.0 15.0 20.0 25.0

Distance around arch, m

Be

nd

ing

Mo

me

nt,

kN

m

Dynamic Lin Dyn, reduced soil stiffness Dyn, reduced soil&beam stiff

Page 20: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Maximum Moments, 15m CoverMaximum Moments, 15m Cover

-250

-200

-150

-100

-50

0

50

100

150

200

250

Standard Stiffness Reduced Soil Stiffness Reduced Soil and Beam

Ben

din

g M

om

ent,

kN

m

Pseudo-Static, +ve Resp. Spect. +ve Pseudo-Static, -ve Resp. Spect. -ve

Page 21: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Axial Load - Seismic Increment Axial Load - Seismic Increment or reduction, 15m Coveror reduction, 15m Cover

15m Cover Axial Loads, Seismic Increment

0

200

400

600

800

1000

1200

0.0 5.0 10.0 15.0 20.0 25.0

Distance around arch, m

Axi

al F

orc

e, k

N

Pseudo Static Response Spectrum

Page 22: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

AnimationsAnimations

First mode shape - 3m and 15 m cover, horizontal and vertical– Arch + Fill– Fill only

Page 23: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Moment-CurvatureMoment-Curvature

Page 24: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Push-over analysis, 15m CoverPush-over analysis, 15m Cover

-800

-600

-400

-200

0

200

400

600

800

0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0

Crown X Displacement, mm

Ben

din

g M

om

ent,

kN

m

Min Moment Max Moment

Page 25: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

AnimationsAnimations

Push-over analysis– 15 m fill– 3 m fill

Page 26: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

ConclusionsConclusions

Buried arch structures with low to moderate axial loads have a large reserve ductility.

Where the failure mode is concrete compression failure under moderate earthquake loading is a possibility.

Bending moments found in the dynamic analyses were up to 50% higher than the static analysis results.

Page 27: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

RecommendationsRecommendations Structure classification be related to fill height, rather than

span. Response modification factor to be related to the capacity

reduction factor. BEDC-1 and BEDC-2: design for vertical and horizontal

earthquake loads, using static or dynamic analysis. BEDC-3 and BEDC-4: design for vertical and horizontal

earthquake loads, using dynamic analysis. Determine the fundamental period from computer analysis

or formula for BEDC-1 and 2 structures.

– T = 0.055 0.5 seconds = deflection in millimetres at ground surface above the arch

under 1g horizontal load.

Page 28: Seismic Design of Buried Structures Doug Jenkins Interactive Design Services.

Further InformationFurther Information

www.interactiveds.com.au