    C O D : C H E M I C A L O X Y G E N D E M A N D

    2

    2.2 With Great Products, Come Great Results

    Chemical Oxygen Demand

    A Complete Laboratory for Wastewater Analysis

    The HI 83224 is a multiparameter bench colorimeter that has 15methods for measurement. It features a powerful interactive usersupport menu system that assists you before, during and afteranalysis.

    An exciting feature of the HI 83224 is its automatic recognitionof bar coded samples. This advanced meter scanseach vial inserted into its chamber and automatically identifiesthe sample and range.

    Product Spotlights

    A Complete Laboratory at Your FingertipsThis compact photometer operates in three different ranges tocover virtually every COD application: 0-150 mg/L, 0-1500 mg/Land 0-15000 mg/L. The HI 83099 meets the design requirementsof USEPA 410.4, guaranteeing high quality measurements suitedfor reporting purposes.

    An Essential Environmental ToolThe HI 83214 multi-parameter photometer is a compactinstrument with ranges and methods tailored to theenvironmental sector.

    HI 83214 is designed and built to perform COD analysis inaccordance with EPA 410.4 and ISO 15705:2002 standards.

    Certified COD ReagentsHANNA COD reagents are available in boxes of 25 vials and issupplied with a HANNA certificate of quality.

    Accuracy and SafetyHANNA The HI 839800 thermo-reactor is constructed of durablematerials with a vial capacity to perform up to 25 digestionssimultaneously. The reactor is equipped with 6 predifined and 2user defined temperature profiles. In addition, HI 839800features power and heat LED indicators and an LCD display.

    p2.4

    p2.8

    p2.10

    p2.13 p2.12

  • 7/21/2019 Section2 COD

    3/14

    www.hannainst.com

    Wastewater needs to be monitored closely to prevent environmental pollution and human illness.

    Oxygen Demand and CODChemical Oxygen Demand (COD) is defined as the amount of specified oxygen that reacts with a sample under controlledconditions. The quantity of oxygen consumed is expressed interms of its oxygen equivalent: mg/L of O 2.

    The HANNA COD method is based on the well established closeddichromate-reflux colorimetric method.

    Moreover the US Environmental Protection Agency (EPA) specifiesthat the dichromate reflux method is the only methodacceptable for reporting purposes . The advantage in using thismethod includes certifiable results as well as high accuracy.

    COD Testing ApplicationsCOD is used as a measurement of pollutants. It is normallymeasured in both municipal and industrial wastewater treatmentplants and gives an indication of the efficiency of the treatmentprocess. COD is measured on both influent and effluent water. Theefficiency of the treatment process is normally expressed as CODRemoval, measured as a percentage of the organic matter purifiedduring the cycle. COD has further applications in power plantoperations, chemical manufacturing, commercial laundries, pulp

    and paper mills, agriculture and animal waste runoff,environmental studies and general education. HANNA equipmentcan be used in the laboratory or for on-site testing. Themeasurement procedure has been designed for ease of use bypersonnel at any skill level.

    Monitoring examples:

    Beyond COD:Nitrogen and PhosphorusThe goal in Wastewater Treatment is not only COD reduction, butalso to control Nitrogen and Phosphorus, which are responsible foreutrophication phenomena in natural environments. COD,

    Nitrogen, and Phosphorus control are performed not only to obeyenvironmental protection laws, but also to optimize plant costs.

    Effective monitoring and control of parameters such asammonia, nitrate, total nitrogen and total reactivephosphorus allow plant managers to profile and improvethe health of aquatic ecosystems. By accurately monitoringlevels of each specific pollutant, operational parameters canbe adjusted to maintain high efficiency of biodegradationtreatments while also minimizing costs.

    NitrogenWhen a treatment plant uses processes like nitrification anddenitrification, it is important to monitor and maintain the

    equilibrium between Ammonia Nitrogen, Nitrate and Total Nitrogen during the bio-treatment. The nitrogen level is importantbecause it relates to the quantity of oxygen provided in thenitrification area. Ammonia is also controlled because it canbecome very toxic for the bacteria responsible for denitrification.

    Phosphorus

    Phosphorus is measured during both biological and chemical dephosphorization. An excessive amount of phosphate dischargedin superficial waters or in bio-treatment tanks causes an increaseof algae and system eutrophication

    TEST NO COD INFLUENT COD EFFLUENT COD REMOVAL

    1 1214 451 62%

    2 948 328 63%

    3 1341 307 77%

    Chemical Oxygen Demand

    Nitrification

    NH4+ + 3/2 O 2 NO2 + 2 H+ + H2O

    NO2 + 1/2 O 2 NO3

    NH4+ + 2 O2 NO3 + 2 H+ + H2O

    Denitrification

    2NO3 + carbon N2 + 3CO2

    nitrosomonas

    nitrobacteria

    nitrobacteria

    denitrobacteria

  • 7/21/2019 Section2 COD

    4/14

    C O D : C H E M I C A L O X Y G E N D E M A N D

    2

    2.4 With Great Products, Come Great Results

    HI 83224

    COD Meter and Multiparameter PhotometerWith Bar Code Recognition of Sample Vials

    A Complete Lab for Wastewater AnalysisThe HI 83224 is a multiparameter bench photometer that has 15 methods formeasurement of COD, chlorine, nitrate, nitrogen and phosphorus.

    Automatic recognition of bar coded samples is an exciting feature of the HI 83224.This advanced meter scans each vial inserted into the vial holder and automaticallyidentifies the sample method and range. This feature eliminates errors and simplifiesthe testing process.

    The HI 83224 features a powerful interactive user support system that assists you before,during and after analysis. On-screen tutorials guide you through set-up, calibration andmeasurement while context sensitive help screens are available at a push of a button.HI 83224 uses a new series of pre-dosed reagent vials for the 15 methods. Each reagentvial is bar coded with specific reagent information at our factory (with the exception of chlorine). This information is automatically scanned by the HI 83224 to assure thatthe vial and method are the same.

    Users have the choice of operating the HI 83224 in automatic mode, semi-automaticmode and manual mode.

    HI 83224 can log and recall up to 200 different measurements. Stored data includesparameter, test results, sample number, lot number, instrument id, date and time. HI83224 bench photometer can be connected to a PC via USB. The HI 92000 Windowscompatible software (optional) aids users in managing data.

    Measures Ammonia,Chlorine, COD, Nitrate,Nitrogen and Phosphorus Bar code reader detectsthe method and range

    automatically Three operation modes:

    Automatic, Semi-automatic and Manual

    Bar coded pre-dosedreagent vials On-screen step-by-steptutorial Logs up to 200 samples Context sensitive help

    screen at a touch of a

    button Selection of languages USB connection Graphic LCD

    Operating ModeThe instrument has 3 operating modes.In Automatic mode , no user involvement isrequired in the method selection.In Semi-Automatic mode , user involvement isrequired when a different vial is identifiedrelated to the current method.In Manual mode , the user involvement isrequired at every level in the method selection.

  • 7/21/2019 Section2 COD

    5/14

    www.hannainst.com

    HI 83224

    COD Meter and Multiparameter PhotometerWith Bar Code Recognition of Sample Vials

    Automatic Sample ScanningAvoid vial confusion andwrong samples with bar code

    identificationSample vials inserted into the HI 83224are identified using bar codes. The barcodes for different methods are shown inthe table below. For parameters that dontuse a bar coded reagent, the vials suppliedwith the instrument should be used. Thebar code has 4 digits. The first 2 digits arefor parameter identification and thesecond 2 digits are for reagent lot ID.

    HI 83224 has a powerful interactive helpsystem that assists the user during theanalysis process. At a touch of a button,

    users can get detailed help tailored to thecurrent information on the LCD. A tutorial mode is also available and can be accessedvia the setup menu.

    Part Code Method Vial bar codeHI 94764A-25 Ammonia, LR 01xx

    HI 94764B-25 Ammonia HR 02xx

    HI 93701-01 Chlorine, Free N/A

    HI 93711-01 Chlorine, Total N/A

    HI 94766-50 Nitrate 05xx

    HI 94767A-50 Nitrogen, Total LR 16xx06xx

    HI 94767B-50 Nitrogen, Total HR 17xx07xx

    HI 94754A-25 Oxygen Demand, Chemical (COD) LR 12xx

    HI 94754B-25 Oxygen Demand, Chemical (COD) MR 13xxHI 94754C-25 Oxygen Demand, Chemical (COD) HR 24xx

    HI 94758A-50 Phosphorus, Reactive 30xx

    HI 94758B-50 Phosphorus, Acid Hydrolyzable 31xx

    HI 94758C-50 Phosphorus, Total 32xx

    HI 94763A-50 Phosphorus, Reactive HR 33xx

    HI 94763B-50 Phosphorus, Total HR 34xxNote: xx represents the reagent lot code.

    Vial IdentificationVials for different methods can be distinguished by a bar code printed on the vial and thecap color.

    IdentificationBar coded vials provide automatic recognition of samples and ranges.Once placed in the holder, the HI 83224 scans thesample and displays the results on-screen.

  • 7/21/2019 Section2 COD

    6/14

    C O D : C H E M I C A L O X Y G E N D E M A N D

    2

    2.6 With Great Products, Come Great Results

    HI 83224

    COD Meter and Multiparameter PhotometerWith Bar Code Recognition of Sample Vials

    D i s p l a y E x a m p l e s

    Setup ScreenThe HI 83224s extensive setup screen allowsusers to adjust the screen display as well as dateand time formats, language and more!

    Data ManagementKeep track of your data with the HI 83224 quicklyand easily. Save and recall up to 200measurements at any time complete with dateand time stamps.

    TutorialIf enabled a short message is displayed on theLCD providing information about the currentaction.Use the function key to enable/disable the

    tutorial mode.

    HELP ScreensThe HELP key gives users information aboutthe current screen, support numbers andaccessories.

    Errors and WarningsThe instrument displays messages if errorconditions occur or when measured values areoutside the expected range. These messagesare described below.

    Barcode Error: The instrument cannot identifythe vials bar code or the vial has no code.

    Wrong vial: The expected bar code is notfound.

    No Light: The light source is not functioningproperly.

    Light Leak: There is too much light enteringthe cell for accurate measurement.

    Inverted vials: The sample and the zero vialsare inverted.

    Wrong vial:The current method doesntcorrespond to the current vial.

    Different reagent lot: The reagent lot doesntcorrespond to the current lot code.

  • 7/21/2019 Section2 COD

    7/14

    www.hannainst.com

    HI 83224

    COD Meter and Multiparameter PhotometerWith Bar Code Recognition of Sample Vials

    ORDERING INFORMATION

    HI 83224-01 (115V) and HI 83224-02 (230V) aresupplied with sample vials (10), vial cleaningcloths (4), scissors and instruction manual.

    SOLUTIONS and REAGENTS

    HI 93701-01 100 free chlorine tests

    HI 93701-03 300 free chlorine testsHI 93711-01 100 total chlorine testsHI 93711-03 300 total chlorine testsHI 94754A-25 25 COD LR testsHI 94754B-25 25 COD MR testsHI 94754C-25 25 COD HR testsHI 94758A-50 50 reactive phosphorus testsHI 94758B-50 50 acid hydrolyzable

    phosphorus testsHI 94758C-50 50 total phosphorus testsHI 94763A-50 50 reactive phosphorus HR tests

    HI 94763B-50 50 total phosphorus HR testsHI 94764A-25 25 ammonia LR testsHI 94764B-25 25 ammonia HR testsHI 94766-50 50 nitrate testsHI 94767A-50 50 total nitrogen LR testsHI 94767B-50 50 total nitrogen HR tests

    HI 94703-50 Vial cleaning solution, 250 mL ACCESSORIES

    HI 839800-01 HANNA Reactor (115 Vac)HI 839800-02 HANNA Reactor (230 Vac)HI 731318 Cloth for wiping vials (4)HI 731340 200 L automatic pipetteHI 731341 1000 L automatic pipetteHI 731342 2000 L automatic pipetteHI 731350 Tips for HI 731340 (25)HI 731351 Tips for HI 731341 (25)HI 731352 Tips for HI 731342 (4)

    HI 740142 1 mL graduated syringe

    HI 740143 1 mL graduated syringe (6 pcs)

    HI 740144 Pipette tip (6 pcs)

    HI 740157 Plastic refilling pipette (20 pcs)

    HI 740216 Test tube cooling rack (25 holes)

    HI 740217 Laboratory bench safety shield

    HI 92000 Windows Compatible Software

    HI 731340 200 L Automatic Pipette

    For chlorine analysis, liquid reagents are also available.

    METHOD RANGE RESOLUTION PRECISION METHOD REAGENT CODE

    Ammonia LR 0.00 to 3.00 mg/L (as NH3-N) 0.01 mg/L 0.03 @ 1.50 mg/L Nessler HI 94764A-25 (25 tests)

    Ammonia HR 0 to 100 mg/L (as NH3-N) 1 mg/L 3 @ 50 mg/L Nessler HI 94764B-25 (25 tests)

    Chlorine, free 0.00 to 5.00 mg/L

    0.01 mg/L from0.00 to 0.99 mg/L;0.1 mg/L above

    0.99 mg/L

    0.04 @ 1.00 mg/L DPD HI 93701-01 (100 tests)

    Chlorine, total 0.00 to 5.00 mg/L

    0.01 mg/L from0.00 to 0.99 mg/L;0.1 mg/L above

    0.99 mg/L

    0.04 @ 1.00 mg/L DPD HI 93711-01 (100 tests)

    Chemical Oxygen Demand LR 0 to 150 mg/L (as COD) 1 mg/L 4 @ 150 mg/L Dichromate, Mercuric Sulfate HI 94754A-25 (25 tests)

    Chemical Oxygen Demand MR 0 to 1500 mg/L (as COD) 1 mg/L 22 @ 1000 mg/L Dichromate, Mercuric Sulfate HI 94754B-25 (25 tests)

    Chemical Oxygen Demand HR 0 to 15000 mg/L (as COD) 10 mg/L 220 @ 10000 mg/L Dichromate, Mercuric Sulfate HI 94754C-25 ( 25 tests)

    Nitrate 0.0 to 30.0 mg/L (as NO3-N) 0.1 mg/L 0.5 @ 25 mg/L Chromotropic Acid HI 94766-50 (50 tests)

    Nitrogen, Total LR 0.0 to 25.0 mg/L (as N) 0.1 mg/L 0.5 @ 15 mg/L Chromotropic Acid HI 94767A-50 (50 tests)

    Nitrogen, Total HR 10 to 150 mg/L (as N) 1 mg/L 3 @ 75 mg/L Chromotropic Acid HI 94767B-50 (50 tests)

    Phosphorus,Acid Hydrolyzable

    0.00 to 1.60 mg/L (as P) 0.01 mg/L 0.02 @ 0.80 mg/L Ascorbic acid HI 94758B-50 (50 tests)

    Phosphorus, Reactive 0.00 to 1.60 mg/L (as P) 0.01 mg/L 0.02 @ 0.80 mg/L Ascorbic acid HI 94758A-50 (50 tests)

    Phosphorus, Reactive HR 0.0 to 32.6 mg/L (as P) 0.1 mg/L 1.0 @ 25.0 mg/L Vanadomolybdophosphoric acid HI 94763A-50 ( 50 tests)

    Phosphorus, Total 0.00 to 1.15 mg/L (as P) 0.01 mg/L 0.02 @ 0.80 mg/L Ascorbic acid HI 94758C-50 (50 tests)Phosphorus, Total HR 0.0 to 32.6 mg/L (as P) 0.1 mg/L 1.0 @ 25.0 mg/L Vanadomolybdophosphoric acid HI 94763B-50 ( 50 tests)

    Some analytical methods require digestion of the sample. For digestion of the vials, use the HANNA HI 839800 reactor only.For safety, the optional HI 740217 safety shield and HI 740216 test tube cooling rack for the HI 839800 are strongly recommended.

    SPECIFICATIONS HI 83224

    Light source Tungsten lamps with narrow-band interference filters

    Light detector Silicon photocells

    Data Logging Up to 200 samples

    Power supply 230 Vac or 115Vac power adapter

    Dimensions 235 x 212 x 143 mm (9.2 x 8.34 x 5.62)

    Weight 2.3 kg (5.1 lb)

  • 7/21/2019 Section2 COD

    8/14

    C O D : C H E M I C A L O X Y G E N D E M A N D

    2

    2.8 With Great Products, Come Great Results

    This compact photometer operates in three different ranges tocover virtually every COD application: 0-150 mg/L, 0-1500 mg/Land 0-15000 mg/L. The HI 83099 meets the design requirementsof USEPA 410.4, guaranteeing high quality measurements suitedfor reporting purposes.

    The HI 83099 can be operated manually or from a PC via the built-in RS232 port. The collected/logged data can be downloaded foranalysis and documented with the HI 92000 application software.

    HI 83099 is one of the most versatile photometers on the market.In addition to COD, this meter measures up to 36 of the mostimportant water quality parameters.

    HI 83099 runs for hours on two common 9V batteries. In

    addition, it can operate continuously with a 12 Vdc adapter.

    HI 83099 is extremely simple to use. The front mask lists all the

    parameters in a numerical order and the display shows the same

    numbers for quick reference during testing.

    The meter can be zeroed in seconds and the reagents cost much

    less than what you may have been paying.

    All this and much more at a fraction of the cost of expensive and

    complex spectrophotometers!

    Measurement ProcedureThe entire COD measurement processhas been designed for ease of use bypersonnel at any skill level. Inaddition, all HANNA equipment hasbeen designed for maximum safetyduring handling and testing with aminimum amount of waste. Even anovice can safely run accurate CODtests in just 3 simple steps: 1. Fill the pre-dosed

    vial with the sample2. Place the vial in the

    HI 839800 reactor(sold separately)and set the timer

    3. Place the vial in theHANNA HI 83099and read the results

    Easy COD measurement HI 83099 multi-parameter photometer ispre-calibrated to measure COD levels at threeranges at the touch of a key pad. Simply usethe scroll button to select the desired rangeand begin reading. HI 83099 automaticallyselects the correct wavelength for thechosen range.

    Outstanding measurement quality HI 83099 employs an advanced opticalsystem, assuring high accuracy measurementsthroughout the entire range. The opticscombine the power of a miniature lightsource with the precision of a narrow bandinterference filter.

    Save space in your laboratory.The compact size of the HI 83099photometer allows the user to eliminate theclutter of bulkier and more costlyspectrophotometers currently being used.Measuring 23 x 17 x 7 cm and weighing lessthan 700 grams, HI 83099 can betransported with ease from place to place.

    HI 83099

    COD MeterMeasure COD and 36 Additional Parameters

    A Complete Laboratory at Your Fingertips

  • 7/21/2019 Section2 COD

    9/14

    www.hannainst.com

    ORDERING INFORMATION

    HI 83099-01 (115V) and HI 83099-02 (230V) issupplied with 3 glass cuvets, cell protective cap,batteries, 12 Vdc adapter and instructions

    SOLUTIONS

    HI 93703-50 Cuvet cleaning solution, 250 mL

    ACCESSORIES The following accessories and spare parts havebeen specially designed for COD analysis tomake your measurements simpler and safer.HI 3898 Test kit for fast analysis of

    chloride concentrationHI 839800-01 HANNA instruments reactor

    (115 Vac)HI 839800-02 HANNA instruments reactor

    (230 Vac)HI 151-00 Thermometer with stainless

    steel probeHI 710005 115 Vac / 12 Vdc power adapterHI 710006 230 Vac / 12 Vdc power adapterHI 731318 Tissue for wiping cuvets (4)

    HI 731321 Measurement cuvet (4)HI 731325N Cuvet cap (4)HI 731340 200 L automatic pipetteHI 731341 1000 L automatic pipetteHI 731342 2000 L automatic pipetteHI 731350 Tips for 200 L automatic pipette

    (25)HI 731351 Tip for 1000 L automatic pipette

    (25)HI 731352 Tip for 2000 L automatic pipette

    (4)HI 740216 Test tube cooling rack

    (25 tube capacity)HI 740217 Laboratory bench safety shieldHI 740219 COD test tube adapter for

    HI 83099HI 92000 Windows compatible

    application softwareHI 920010 Serial cable for PC connection

    (9 pin)

    Notes:* Method with chromium-sulfuric acid is officially recognized by EP

    for wastewater analysis.** The HI 93754F-25 and HI 93754G-25 method follows the official

    method ISO 15705. This method is recommended for general purpose analysis with no

    chloride interference. For chlorine analysis, liquid reagents are also available.

    HI 83099

    COD Meter for COD and 36 Additional Parameters

    SPECIFICATIONS HI 83099

    Light source 4 tungsten lamps with narrow-band interference filters at 420/525/575/610 nm

    Light detector 4 silicon photocells

    Power supply (2) 9V batteries or 12 Vdc adapter

    Auto-off after 10 minutes of non-use

    Environment 0 to 50C (32 to 122F); RH max 95%

    Dimensions 230 x 165 x 70 mm (9.1 x 6.5 x 2.6)

    Weight 640 g (1.4 lbs.)

    PARAMETER RANGE METHOD REAGENT CODE

    Aluminum 0.00 to 1.00 mg/L Aluminon HI 93712-01

    Ammonia LR 0.00 to 3.00 mg/L Nessler HI 93700-01

    Ammonia MR 0.00 to 9.99 mg/L Nessler HI 93715-01

    Bromine 0.00 to 8.00 mg/L DPD HI 93716-01

    Chlorine, free 0.00 to 2.50 mg/L DPD HI 93701-01

    Chlorine, total 0.00 to 3.50 mg/L DPD HI 93711-01

    Chlorine dioxide 0.00 to 2.00 mg/L Chlorophenol red HI 93738-01

    Chromium VI LR 0 to 300 g/L Diphenylcarbohydrazine HI 93749-01

    Chromium VI HR 0 to 1000 g/L Diphenylcarbohydrazine HI 93723-01

    COD LR 0 to 150 mg/LDichromate EPA*

    Dichromate Hg-freeDichromate ISO**

    HI 93754D-25HI 93754F-25HI 93754A-25

    COD MR0 to 1500 mg/L

    0 to 1000 mg/L

    Dichromate EPA*Dichromate Hg-free

    Dichromate ISO**

    HI 93754B-25HI 93754E-25HI 93754G-25

    COD HR 0 to 15000 mg/L Dichromate HI 93754C-25

    Color 0 to 500 PCU Platinum Cobalt

    Copper LR 0 to 990 g/L Bicinchoninate HI 95747-01

    Copper HR 0.00 to 5.00 mg/L Bicinchoninate HI 93702-01

    Cyanide 0.000 to 0.200 mg/L Pyridine-Pyrazalone HI 93714-01

    Cyanuric acid 0 to 80 mg/L Turbidimetric HI 93722-01

    Fluoride 0.00 to 2.00 mg/L SPADNS HI 93729-01

    Hardness (Calcium) 0.00 to 2.70 mg/L Calmagite HI 93720-01

    Hardness (Magnesium) 0.00 to 2.00 mg/L EDTA HI 93719-01

    Hydrazine 0 to 400 g/L p-Dimethylaminobenzaldehyde HI 93704-01

    Iodine 0.0 to 12.5 mg/L DPD HI 93718-01

    Iron LR 0 to 400 g/L TPTZ HI 93746-01

    Iron HR 0.00 to 5.00 mg/L Phenantroline HI 93721-01

    Manganese HR 0.0 to 20.0 mg/L Periodate oxidation HI 93709-01

    Manganese LR 0 to 300 g/L PAN HI 93748-01

    Molybdenum 0.0 to 40.0 mg/L Mercaptoacetic acid HI 93730-01

    Nickel HR 0.00 to 7.00 g/L Photometric HI 93726-01

    Nitrate 0.0 to 30.0 mg/L Cadmium reduction HI 93728-01

    Nitrite LR 0.00 to 0.35 mg/L Diazotation HI 93707-01

    Nitrite HR 0 to 150 mg/L Ferrous sulfate HI 93708-01

    Oxygen, dissolved 0.0 to 10.0 mg/L Winkler HI 93732-01

    pH 6.5 to 8.5 pH Phenol red HI 93710-01

    Phosphate LR 0.00 to 2.50 mg/L Ascorbic acid HI 93713-01

    Phosphate HR 0.0 to 30.0 mg/L Amino acid HI 93717-01

    Phosphorus 0.0 to 15.0 mg/L Amino acid HI 93706-01

    Silica 0.00 to 2.00 mg/L Dimolybdate HI 93705-01

    Silver 0.000 to 1.000 mg/L PAN HI 93737-01

    Zinc 0.00 to 3.00 mg/L Zincon HI 93731-01

    HI 731340 200 L Automatic Pipette

  • 7/21/2019 Section2 COD

    10/14

    C O D : C H E M I C A L O X Y G E N D E M A N D

    2

    2.10 With Great Products, Come Great Results

    HI 83214

    Wastewater COD MeterDesigned for Wastewater Analysis

    The new HI 83214 multi-parameter photometer is a compactinstrument featuring different ranges and methods, suitable for awide range of applications.

    HI 83214 is designed and built to perform COD analysis inaccordance with EPA 410.4 and ISO 15705:2002 standards.

    Ensuring accurate and repeatable results, it is the ideal tool fordocumenting waste treatment processes.

    Besides the fundamental parameter of COD, HI 83214 alsomeasures total ammonia nitrogen and total reactive phosphorus.

    The instrument can be connected to a PC through an RS232 serial port and stored measurements can be downloaded using HANNAHI 92000 software.

    HI 83214, allows a complete wastewater analysis in a singlepowerful instrument.

    Measurement ProcedureThe entire COD measurement processhas been designed for ease of use by

    personnel at any skill level. Inaddition, all Hanna equipment hasbeen designed for maximum safetyduring handling and testing with aminimum amount of waste. Even anovice can safely run accurate CODtests in just 3 simple steps:

    1. Fill the pre-dosedvial with the sample

    2. Place the vial in theHI 839800 reactor(sold separately)and set the timer

    3. Place the vial in theHANNA HI 83214and read the results

    Easy COD measurement HI 83214 multi-parameter photometer ispre-calibrated to measure COD levels at threeranges at the touch of a key pad. Simply usethe scroll button to select the desired rangeand begin reading. HI 83214 automaticallyselects the correct wavelength for the chosenrange.

    Outstanding measurement quality HI 83214 employs an advanced optical system,assuring high accuracy measurementsthroughout the entire range. The opticscombine the power of a miniature lightsource with the precision of a narrow bandinterference filter.

    Save space in your laboratory.The compact size of the HI 83214photometer allows the user to eliminate theclutter of bulkier and more costlyspectrophotometers currently being used.Measuring 23 x 17 x 7 cm and weighing lessthan 700 grams, HI 83214 can betransported with ease from place to place.

    An EssentialEnvironmental Tool

    In the Field ...

  • 7/21/2019 Section2 COD

    11/14

    PARAMETER RANGE METHOD REAGENT CODE

    Ammonia, LR 0.00 to 3.00 mg/L Nessler HI 93764A-25

    Ammonia, HR 0 to 100 mg/L Nessler HI 93764B-25

    Chlorine, free 0.00 to 5.00 mg/L DPDHI 93701-01,HI 93701-03

    Chlorine, total 0.00 to 5.00 mg/L DPDHI 93711-01,HI 93711-03

    Nitrate 0.0 to 30.0 mg/L Chromotropic acid HI 93766-50

    Nitrogen, total 0.0 to 25.0 mg/L Chromotropic acid HI 93767A-50

    Nitrogen, total HR 10 to 150 mg/L Chromotropic acid HI 93767B-50

    COD LR, EPA* 0 to 150 mg/L Dichromate HI 93754A-25

    COD MR, EPA* 0 to 1500 mg/L Dichromate HI 93754B-25

    COD HR 0 to 15000 mg/L Dichromate HI 93754C-25

    COD LR, Mercury-free 0 to 150 mg/L Dichromate, mercury-free HI 93754D-25

    COD MR, Mercury-free 0 to 1500 mg/L Dichromate, mercury-free HI 93754E-25

    COD LR, ISO** 0 to 150 mg/L Dichromate HI 93754F-25

    COD MR, ISO** 0 to 1000 mg/L Dichromate HI 93754G-25

    Phosphorus, reactive 0.00 to 5.00 mg/L Ascorbic acid HI 93758A-50

    Phosphorus, acidhydrolyzable

    0.00 to 5.00 mg/L Ascorbic acid HI 93758B-50

    Phosphorus, total 0.00 to 3.50 mg/L Ascorbic acid HI 93758C-50

    Phosphorus, reactive HR 0.0 to 100.0 mg/L Vanadomolybdophosphoric ac id HI 93763A-50

    Phosphorus, total HR 0.0 to 100.0 mg/L Vanadomolybdophosphoric ac id HI 93763B-50

    www.hannainst.com 2

    HI 731340 200 L Automatic Pipette

    HI 83214

    Wastewater COD MeterDesigned for Wastewater Analysis

    Notes:* Method with chromium-sulfuric acid is officiallly recognized by

    EPA for wastewater analysis.** The HI 93754F-25 and HI 93754G-25 method follows the official

    method ISO 15705. This method is recommended for general purpose analysis with no

    chloride interference

    SPECIFICATIONS HI 83214

    Light Source 3 tungsten lamps with narrow-band interference filters at 420/525/610 nm

    Light Detector 3 silicon photocells

    Power Supply 2 x 9V batteries or 12 Vdc adapter

    Auto-off after 10 minutes of non-use

    Environment 0 to 50C (32 to 122F); RH max 95%

    Dimensions / Weight 230 x 165 x 70 mm (9.1 x 6.5 x 2.6) / 640 g (1.4 lbs.)

    ORDERING INFORMATION

    HI 83214-01 (115V) and HI 83214-02 (230V) issupplied with 5 glass cuvets, batteries, 12 Vdcadapter and instructions

    SOLUTIONS

    HI 93703-50 Cuvet cleaning solution, 250 mL

    ACCESSORIES The following accessories and spare parts havebeen specially designed for COD analysis tomake your measurements simpler and safer.HI 3898 Test kit for fast analysis of

    chloride concentrationHI 839800-01 HANNA instruments reactor

    (115 Vac)HI 839800-02 HANNA instruments reactor

    (230 Vac)HI 151-00 Thermometer with stainless

    steel probeHI 710005 110 Vac / 12 Vdc power adapterHI 710006 220 Vac / 12 Vdc power adapterHI 731310 9V battery (10)

    HI 731311 Cuvets with caps for HI 83214HI 731318 Tissue for wiping cuvets (4)HI 731321 Measurement cuvet (4)HI 731325N Cuvet cap (4)HI 731340 200 L automatic pipetteHI 731341 1000 L automatic pipetteHI 731342 2000 L automatic pipetteHI 731350 Tips for 200 L automatic pipette

    (25)HI 731351 Tip for 1000 L automatic pipette

    (25)HI 731352 Tip for 2000 L automatic pipette

    (4)HI 740216 Test tube cooling rack

    (25 tube capacity)HI 740217 Laboratory bench safety shieldHI 92000 Windows compatible

    application softwareHI 920010 Serial cable for PC connection

    (9 pin)

    ... or in the lab.

  • 7/21/2019 Section2 COD

    12/14

    C O D : C H E M I C A L O X Y G E N D E M A N D

    2

    2.12 With Great Products, Come Great Results

    HI 740216 Test Tube Cooling Rack

    Certified COD ReagentsHANNA COD reagents are available in the following formats:

    Each box of 25 vials is supplied with a HANNA certificateof quality.

    The reagents are traceable to NIST SRM 930.

    HANNA also produces mercury-free reagents to be used foranalyzing samples without chloride.

    Notes:* Method with chromium-sulfuric acid is officiallly recognized by EPA for wastewater ana** The HI 93754F-25 and HI 93754G-25 method follows the official method ISO 15705.*** This method is recommended for general purpose analysis with no chloride interferance.

    CODE METHOD RANGE

    HI 93754A-25 EPA* 0 to 150 mg/L

    HI 93754B-25 EPA* 0 to 1500 mg/L

    HI 93754C-25 0 to 15000 mg/L

    HI 93754D-25 Mercury-free*** 0 to 150 mg/L

    HI 93754E-25 Mercury-free*** 0 to 1500 mg/L

    HI 93754F-25 ISO** 0 to 150 mg/L

    HI 93754G-25 ISO** 0 to 1000 mg/L

    Three measurement ranges to satisfy each need As COD levels vary depending on the application and processmeasuring points, HANNA offers reagents to cover three separateranges. Simply choose the best range for your application:

    low range: 0 to 150 mg/L O 2medium range: 0 to 1500 mg/L or 0 to 1000 mg/L O 2high range : 0 to 15000 mg/L O 2

    Accurate and repeatable measurementsHANNA COD reagents have been developed in accordance withStandard Methods 5220D, USEPA 410.4 and ISO15705:2002 methods.

    Pre-dosed vialsHANNA vial contains approx. 3 mL of pre-dosed reagent. The operator

    just needs to add a small quantity of the sample - 2 mL for LR and

    MR, and 0.2 mL for HR analysis. Quick and accurate measurements

    With pre-dosed vials test preparation time is dramatically reduced.There is no time-consuming reagent preparation procedure orglassware cleaning.

    Safe reagentsHANNA COD reagents are safe for operators and the environment. Vialsand caps have been designed to avoid accidental reagent spills. Thanksto the pre-dosed reagents, the amount of chemicals is minimized.

    HI 93754

    COD Certified Reagentsin 3 Measurement Ranges

  • 7/21/2019 Section2 COD

    13/14

  • 7/21/2019 Section2 COD

    14/14

    C O D : C H E M I C A L O X Y G E N D E M A N D

    2

    2 14 With G t P d t C G t R lt

    HI 839800-01 HANNA instruments reactor(115 Vac)

    HI 839800-02 HANNA instruments reactor(230 Vac)

    HI 151-00 Thermometer with stainlesssteel probe

    HI 710005 110 Vac / 12 Vdc power adapterHI 710006 220 Vac / 12 Vdc power adapterHI 731310 9V battery (10)HI 731311 Cuvets with caps for HI 83214HI 731318 Tissues for wiping cuvets (4)HI 731321 Measurement cuvets (4)HI 731325N Cuvet caps (4)HI 731340 200 L automatic pipetteHI 731341 1000 L automatic pipetteHI 731342 2000 L automatic pipette

    HI 731350 Tips for 200 L automaticpipette (25)

    HI 731351 Tips for 1000 L automaticpipette (25)

    HI 731352 Tips for 2000 L automaticpipette (4)

    HI 740216 Test tube cooling rack (25 tubecapacity)

    HI 740217 Laboratory bench safety shieldHI 740219 COD test tube adapter for

    HI 83099HI 92000 Windows compatible application

    softwareHI 920010 Serial cable for PC connection

    (9 pin)HI 93703-50 Cuvet cleaning solution,

    230 mL

    COD AccessoriesSpecially Designed for our COD Instruments

    Tailor-Made AccessoriesThe following accessories and spare parts have been specially designed for COD analysisto make your measurements simpler and safer.

    Quick Chloride TestsThe HI 3898 test kit, developedaccording to the ISO 15705:2002 method,determines chloride concentration.

    This very important test is recommendedby ISO, since an excessive presence of chloride can interfere with the COD analysis.

    The test gives a fast YES/NO reply to thequestion if chloride will interfere with theCOD analysis. If chloride concentration isgreater than the official maximum level,the solution turns yellow and the sampleneeds to be diluted before performing theCOD test, otherwise if the solution isorange-brown, the sample doesnt need tobe diluted.

    The maximum level allowed is 1000 ppmof Cl - following ISO methods, or 2000 ppm

    of Cl - for US EPA, APHA, AWWA and WEmethods.

    SPECIFICATIONS HI 3898

    Range1000 ppm Cl - (ISO)2000 ppm Cl - (EPA)

    Analysis Method visual evaluation

    Sample Volume 2 mL

    Number of Tests 100

    Dimensions 120 x 110 x 90 mm (4.7 x 4.3 x 3.5)

    Weight 200 g (7.0 oz.)

    ORDERING INFORMATION

    HI 3898 is supplied with HI 3898-0 Reagent 25mL (4), Chloride Indicator 7 mL(1), glass cuvetwith plastic stopper (1) and calibrated syringesof 1.0 ml with tip (2).

    SOLUTIONS

    HI 93703-50 Cuvet cleaning solution (250 mL) ACCESSORIES

    HI 731342 2000 L automatic pipetHI 731352 Tips for 2000 L automatic

    pipet (4)HI 740142 1 mL graduated syringeHI 740143 1 mL graduated syringes (6)HI 740144 Tips for 1 mL graduated syringes (6)HI 731318 Tissues for wiping cuvets (4)HI 731331 Large cuvets (4)HI 731335 Cap for large cuvets (4)

    HI 3898

    Chloride Test KitUsed in conjunction with COD