Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The...

8
Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl and XIOC

Transcript of Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The...

Page 1: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

XControl XC100 +XI/OC I/O-Modules + XVision

Text-Display

The convincing machine and system control by Moeller

XControl and XIOC

Page 2: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Control XControl XC100

Visualization XVision Text Display

Input and Output with XI/OC Modules

Software XSoft for all Xsystem applications

The components for small and medium applications

Page 3: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

The compact controls with integrated I/O

XControl XC100

XC100

Page 4: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Display PLC-Status: Run / Stop, SFOperating mode switch: Run / Stop

Status display local I/O

Local I/O8 DI 24 VDC6 DO 24 VDC

Battery for Retention and Real time clock

CAN-interface

with integrated T-connector

(Connection of two CAN-lines via cage-clamp terminal)

Slot for Multi-Media-memory card

RS232(RJ45-socket)

LEDs

(16 or 32 MB)

XControl XC100: The operation elements

Page 5: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Inputs / Outputs8 DI 24 VDC6 DO 24 VDC

Flexible Connection - Screw or cage clamp terminals- Terminal blocks completely removable

XControl XC100: Local I/O

Page 6: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

0, 1, 2 , 3 , ......... , 13, 14 , 15

<- max. 510 mm ->

Flexible connectivity:

- Pluggable terminals

- tension cage clamp or screw

Digital inputs / outputs

- 24VDC 8, 16 and 32 point I/Q

- 24VDC configurable (4DI, 12 DI/DO, 4DO as 2A)

- 230VAC 16 DI

Analog inputs / outputs

-Current, Voltage, Temperature up to 8 channels per module

-Fast (1ms) 2AI-1AO or 4AI-2AO

Many technology modules

Counters, Incremental encoder inputs, Communication

Generous extensibility:

- Up to 15 XI/OC modules, only 510mm wide

- Max. 494 digital I/O (15 * 32 +14)

- Max. 40 Analog I/O (at present max 5 modules due to max. power consumption)

Locale I/O extension

Page 7: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

CPU• XC100 = 0.5 ms / 1000 instructions

• PLC real time system

Working memory SRAM

- Program

- Recipes

- Visu-Texts

CANopen

Real time clock

Battery

Multi-Media-Card- Fieldbus-Master

- Control networking

(XControl to XControl)

- Programming port

- Modem, Printer etc.

- configurable: 1.2 thru

115 kBaud

RS 232

- Program 64 / 128 kB

- Retentive Data 4 / 8 kB

- Data 60 / 120 kB

Internal Flash memory- Operating system

- Data of the operating system

XV-Flash- with XV devices

- 512 kB for Visu-Texts

- 8 digital Inputs

- 6 digital Outputs

- galvanically separated

Locale I/O

XControl XC100: Setup of the CPU

Page 8: Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

CPU

Working memory SRAM

- 1 Program

- Recipes

- Visualization Texts

Multi-Media-Card

- Programming access

- Modem

- Barcode reader etc.

- 1.2 .. 115 kBaud

RS 232 (XC100/200) Ethernet (XC200)

- 1 Program 64-128 kB

- Retentive Data 4-8 kB

- Data 60 / 120 kB

Create boot project

Download

Program on Multi-Media-Card has priority

STOP RUN

The program in the SRAMis started

Battery

XControl XC100: Load, Backup and Start