Schneider - TeSys Motor

8
Motor starters up to 65 A TeSys Play your own combination!

Transcript of Schneider - TeSys Motor

Page 1: Schneider - TeSys Motor

Motor starters up to 65 ATeSys Play your own combination!

Page 2: Schneider - TeSys Motor

TeSys motor startersup to 65 A

Increase automationDirect Control Quickfit pre-wired control technology

■ Control and save

Control TeSys low consumption contactor from your PLC outputs.

■ Pre-wire and communicate

The TeSys Quickfit pre-wired solution allows communication with PLCs via Advantys STB interface or a splitter box.

Save space

45 and 55 mm widths Compact DC contactor S-shape and multiple tap-off busbar systems

■ SmallerWith a width of 45 mm up to 38 A and 55 mm up to 65 A, TeSys motor starters fit more easily into electrical enclosures.

■ Install without wiring

Special busbar systems allow fast pre-wiring of power connections. Assemble a motor starteron a single rail with the “S” shape busbar system.

Page 3: Schneider - TeSys Motor

Increase reliability and safety

Auxiliary safety contacts Spring terminals and Type 2 tested motor starters

Save timeSpring terminals andReverser kitCommon accessories range

■ Combine without wiring

Simple manual unclipping of a terminal block allows you to combine the circuit-breaker with the contactor. Assembling a reverser becomes child’s play. Using standard contactors, you can build your reversing starter in less than 2 minutes on the clock, without any risk of wiring errors. Flexibility using add-on blocks and accessories, that are common throughout the 9 to 65A motorstarters range.

■ Increase safety

Mechanically linked auxiliary and mirror contactsensure reliable return of information and allow you to include TeSys contactors in your safety applications.

■ Increase reliability

Spring terminals and Schneider Electric’s new,patented terminal block technologyensure permanent tightening quality by compensating for cable creep.

■ Guarantee performance

Continuity of service is guaranteed by using tested combinations with high breaking capacity.Type 2 coordination allows operation to be resumed more quickly after a short-circuit fault.

Page 4: Schneider - TeSys Motor

TeSys motor starters selection guide

GV2 + LC1D Circuit breaker + contactor TeSysHigh breaking capacity / Icu/400v 130KA 130KA 130KA 130KA 130KA 130KA 130KA

Setting range of thermal trips 0.16…0.25 A 0.25…0.40 A 0.40…0.63 A 0.63…1 A 1…1.6 A 1.6…2.5 A 2.5...4 A

Thermal-magnetic circuit-breaker GV2P02 GV2P03 GV2P04 GV2P05 GV2P06 GV2P07 GV2P08

Standard breaking capacity / Icu/400v 130KA 130KA 130KA 130KA 130KA 130KA 130KA

Setting range of thermal trips 0.16…0.25 A 0.25…0.40 A 0.40…0.63 A 0.63…1 A 1…1.6 A 1.6…2.5 A 2.5...4 A

Thermal-magnetic circuit-breaker GV2ME02 GV2ME03 GV2ME04 GV2ME05 GV2ME06 GV2ME07 GV2ME08

Ie AC-3 (A) 0.2 0.3 0.44...0.6 0.85 1.1...1.5 1.9 2.7...3.6

Ie AC1 (T<60°C) (A) 25 25 25 25 25 25 25

Contactor LC1D09 LC1D09 LC1D09 LC1D09 LC1D09 LC1D09 LC1D09

GV2 + LC1D + LRD Circuit breaker + contactor + thermal relayTeSysHigh breaking capacity / Icu/400v 130KA 130KA 130KA 130KA 130KA 130KA 130KA

Magnetic circuit-breaker GV2L02 GV2L03 GV2L04 GV2L05 GV2L06 GV2L07 GV2L08

Standard breaking capacity / Icu/400v 130KA 130KA 130KA 130KA 130KA 130KA 130KA

Magnetic circuit-breaker GV2LE02 GV2LE03 GV2LE04 GV2LE05 GV2LE06 GV2LE07 GV2LE08

Ie AC3 (A) 0.2 0.3 0.44...0.6 0.85 1.1...1.5 1.9 2.7...3.6

Ie AC1 (T<60°C) (A) 25 25 25 25 25 25 25

Contactor LC1D09 LC1D09 LC1D09 LC1D09 LC1D09 LC1D09 LC1D09

Setting range 0.16…0.25 A 0.25…0.40 A 0.40…0.63 A 0.63…1 A 1…1.7 A 1.6…2.5 A 2.5...4 A

Thermal overload relay cl10A LRD02 LRD03 LRD04 LRD05 LRD06 LRD07 LRD08

Setting range - - - - - - -

Thermal overload relay cl10A - - - - - - -

Setting range - - - - - - 2.5...4 A

Thermal overload relay cl20 - - - - - - LRD1508

Setting range - - - - - - -

Thermal overload relay cl20 - - - - - - -

Standard power ratings of 3-phase motors 50-60 Hz

in category AC3/400V (kw)0.06 0.09 0.12...0.18 0.25 0.37...0.55 0.75 1.1...1.5

Connection : GV2P, GV2ME, LC1D up to 32 A : by screw clamp terminal (for power and control spring terminal, add 3 at the end of

Connection : GV2L, GV2LE, LC1D & LRD up to 32 A : by screw clamp terminal (for power and control spring terminal, add 3 at the end of the reference

Page 5: Schneider - TeSys Motor

TeSys GV3 + LC1D

Coil voltage

Contactor AC Standard LowDC consumption

DC *

50/60 HZ 5,4 W < 2,4 W24 V B7 BD BL48 V E7 ED EL72 V - SD SL110 V F7 FD120 V G7 -220 V M7 MD230 V P7240 V U7380 V Q7400 V V7415 V N7440 V R7

* Only for LC1D40 to D65, please order LAD4DBL accessory for direct control from a PLC.

130KA 130KA 130KA 130KA 100KA 100KA 100KA 100KA 50KA 50KA 50KA

4...6.3 A 6...10 A 6...10 A 9...14 A 12...18 A 12...18 A 17...25 A 23...32 A 30...40 A 37...50 A 48...65 A

GV2P10 GV2P14 GV2P14 GV2P16 GV3P18 GV3P25 GV3P25 GV3P32 GV3P40 GV3P50 GV3P65

130KA 130KA 130KA 15KA 15KA 15KA 15KA 15KA 50KA 50KA 50KA

4...6.3 A 6...10 A 6...10 A 9...14 A 13...18 A 17...23 A 20...25 A 24...32 A 30...40 A 37...50 A 48...65 A

GV2ME10 GV2ME14 GV2ME14 GV2ME16 GV2ME20 GV2ME21 GV2ME22 GV2ME32 GV3P40 GV3P50 GV3P65

4.9 6.5 8.5 11.5 15.5 18.1 22 29 35 41 55

25 25 25 25 32 40 40 50 60 80 80

LC1D09 LC1D09 LC1D09 LC1D12 LC1D18 LC1D25 LC1D25 LC1D32 LC1D40A LC1D50A LC1D65A

130KA 130KA 130KA 50KA 50KA 50KA 100KA 100KA 50KA 50KA 50KA

GV2L10 GV2L14 GV2L14 GV2L16 GV2L20 GV2L22 GV3L25 GV3L32 GV3L40 GV3L50 GV3L65

130KA 130KA 130KA 15KA 15KA 15KA 15KA 15KA 50KA 50KA 50KA

GV2LE10 GV2LE14 GV2LE14 GV2LE16 GV2LE20 GV2LE22 GV2LE22 GV2LE32 GV3L40 GV3L50 GV3L65

4.9 6.5 8.5 11.5 15.5 18.1 22 29 35 41 55

25 25 25 25 32 40 40 50 60 80 80

LC1D09 LC1D09 LC1D09 LC1D12 LC1D18 LC1D25 LC1D25 LC1D32 LC1D40A LC1D50A LC1D65A

4...6 A 5.5...8 A 7...10 A 9...13 A 12...18 A 16...24 A 16...24 A 23...32 A - - -

LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 LRD22 LRD32 - - -

- - - - - - 17...25 A 23..32 A 30...40 A 37...50 A 48...65 A

- - - - - - LRD325 LRD332 LRD340 LRD350 LRD365

4...6 A 5.5...8 A 7...10 A 9...13 A 12...18 A 17...25 A 17...25 A 25...32 A - - -

LRD1510 LRD1512 LRD1514 LRD1516 LRD1521 LRD1522 LRD1522 LRD1532 - - -

- - - - - - 17...25 A 23...32 A 30...40 A 37...50 A 48...65 A

- - - - - - LRD325L LRD332L LRD340L LRD350L LRD365L

TeSys GV3 + LC1D + LRD3

2.2 3 4 5.5 7.5 9 11 15 18.5 22 30

the reference selected). GV3P, LC1D40 to D65 : by EverLink terminal (for control spring terminal, add 3 at the end of the reference selected). Connection by lugs add the digit 6 at the end of the reference selected

selected). GV3L, LC1D & LRD3 : by EverLink terminal (for control spring terminal, add 3 at the end of the reference selected). Connection by lugs add the digit 6 at the end of the reference selected

Page 6: Schneider - TeSys Motor

LC1DAdd-on blocks for TeSys LC1D contactors

Accessories for TeSys GV2-GV3 circuit-breakers

Add-on blocks common to TeSys GV2-GV3 circuit-breakers

SETS OF 3-POLE 63 A BUSBARS

Number of combined GV2 circuit-breakers 2 3 4 5

Bar pitch (1) 45 mm GV2G245 GV2G345 GV2G445 -

54 mm GV2G254 GV2G354 GV2G454 GV2G554

72 mm GV2G272 - GV2G472 -

(1) Protective end cover for unused busbar outlets, reference: GV1G10

SETS OF 3-POLE 115 A BUSBARS

Number of combined GV3 circuit-breakers 2 3

Bar pitch 64 mm GV3G264 GV3G364

TERMINAL BLOCKS

For supply to one or more busbar sets GV2ME/P/L GV3P/L

Connection from the top GV1G09 -

"Large spacing" terminal block UL508 GV2P..H7 GV3P

GV2GH7 GV3G66

PADLOCKING DEVICE

For 4 padlocks Shank diameter 6 mm max., padlocks not supplied

GV2ME/P/L-GV3P/L GV2V03

PADLOCKABLE EXTERNAL OPERATOR

Colour of operator Black handle/blue legend plate Red handle/yellow legend plate

GV2P/L Padlocking In ON and OFF positions GV2AP01 In OFF position GV2AP02

GV2LE Padlocking In ON and OFF positions GV2AP03

GV3P/L Padlocking In ON and OFF positions GV3AP01 In OFF position GV3AP02

CONTACT BLOCK

Instantaneous auxiliary contacts 1”F” 1”0” 1”F” + 1”0” 2”F” 2”0” 2”F” + 2”0” 1”F” + 3”0” 3”F” + 1”0”

Mounting position Front LADN10 LADN01 LADN11 LADN20 LADN02 LADN22 LADN13 LADN31

Side - - LAD8N11 LAD8N20 LAD8N02 - - -

Time delay auxiliary contacts 0.1...3 s 0.1...30 s 10...180 s

Mounting position Front On-delay LADT0 LADT2 LADT4

Off-delay LADR0 LADR2 LADR4

CONTACT BLOCK

Instantaneous auxiliary contacts "F" or "O" "F" and "O" "F" + "F"

Mounting position Left-hand side - GVAN11 (1) GVAN20 (1)

Front GVAE1 GVAE11 (1) GVAE20 (1)

(1) For spring terminal version, add 3 to the end of the reference, example: GVAN11 becomes GVAN113

Fault contact + instantaneous auxiliary contact "F" (fault) + "O" "F" (fault) + "F" "O" (fault) + "O" "O" (fault) + "F"

Mounting position Left-hand side GVAD1001 GVAD1010 GVAD0101 GVAD0110

Front GV3 only GVAED011 (2) GVAED101 (2)

(2) For spring terminal version, add 3 to the end of the reference, example: GVAED011 becomes GVAED0113 (GV3 only)

Short-circuit signalling contact "OF" with common point

Mounting position Left-hand side GVAM11

Page 7: Schneider - TeSys Motor

TeSys motor starter mounting accessories COMBINATION MOUNTING

< 38 A (with GV2 range) < 65 A (with GV3 range)

GV2AF3 (on mounting rail) Without accessory (1)

GV2AF4 (on mounting plate LAD311)

(1) GV3P/L can be ordered without outgoing terminal block. Ex : GV3P651

SIDE-BY-SIDE MOUNTING – S-SHAPE BUSBAR SYSTEM

< 38 A (with GV2 range) < 65 A (with GV3 range)

- GV3S (2)

(2) Can be associated with a combination reverser assembly

COMBINATION REVERSER ASSEMBLY – REVERSER KIT (3)

< 38 A from 40 to 65 A

LAD9R1V LAD9R3

(3) Can be associated with a side-by-side assembly

SEPARATE RELAY MOUNTING – TERMINAL BLOCK

< 38 A (for LRD) < 65 A (for LRD3)

LAD7B106 LAD96560

MOUNTING WITH PRE-WIRED CONTROL TECHNOLOGY – TESYS QUICKFIT MOUNTING KIT (for LC1D..3 contactor with spring terminals)

Motor connection module - Direct 1

Without relay Electronic relay (for DC coil control)

LAD9AP3D1 LAD9AP31

Motor connection module - Reverser 2

Without relay Electronic relay (for DC coil control)

LAD9AP3D2 LAD9AP32

Parallel wiring module

Advantys STB 3 Splitter block 4

4xRJ45 2xHE10 / 8xRJ45

STBEPI2145 LU9G02

1

4

2

3

Page 8: Schneider - TeSys Motor

www.schneider-electric.com

ART. 831641

Schneider Electric Industries S.A.S.

Head office

89 boulevard Franklin Roosevelt

92504 Rueil-Malmaison Cedex

France

http://www.schneider-electric.com

Owing to changes in standards and equipment,

the characteristics given in the text and images

in this document are not binding until they have been confirmed by us.

Design/Production: JAPA

Printed by:

Photos: Schneider Electric

DIA

1ED

1070

901E

N

01/2008