Scan Status Overview
description
Transcript of Scan Status Overview
Scan Status Overview
Scan Status 06/12/10 M. WittgenPage 1
• ToT problem understood and fixed
• Vcal needs to be set at scan initialization
• Was always set to zero in STcontrol
• No loop over charge in STcontrol
• implemented electrons-to-DAC functions for comparison with TurbDAQ
• Most scans yield reasonable results in STcontrol now
• STcontrol can now configure the channel to module input is connected to from configuration file
Timewalk Scans
Scan Status 06/12/10 M. WittgenPage 2
• Basic configuration
• One level 1 trigger
• Loop over strobe delay 0-63 on RCE and
• Vcal 70 -1000 on host (steered by STcontrol)
• VCAL is 10 bit value (0-1023)
• Misrepresented as char/octet in PixelModuleConfig.idl
• fixed to unsigned long (32bit)
STcontrol Status Non-BOC-Scans
Scan Status 06/10/10 M. WittgenPage 3
SCAN HISTO TYPE Runs/Results COMMENTANALOG_TEST OCCUPANCY YES/YES ToT fixed now
DIGITAL_TEST OCCUPANCY YES/YES Works
CROSSTALK_SCAN THRESHOLD YES/NO Needs more debugging. No hits
TOT_CALIB TOT YES/YES Works. See plots
THRESHOLD_SCAN THRESHOLD YES/YES Works.
TIMEWALK_MEASURE OCCUPANCY YES/NO
TDAC_TUNE THRESHOLD YES/(YES) Works in principle. See plot. Some problems with half the FECs
T0_SCAN OCCUPANCY YES/NO No hits.
INTIME_THRESHOLD_SCAN THRESHOLD YES/NO No hits.
INCREMENTAL_TDAC_SCAN THRESHOLD NO/NO STcontrol error
IF_TUNE TOT YES/YES
GDAC_TUNE THRESHOLD YES/YES Works. See plots.
FDAC_TUNE TOT YES/YES Works. See plots
Scan Setup
Scan Status 06/12/10 M. WittgenPage 4
• Tested with module M511958 with HV connected
• one FEC broken
• threshold tuned to 3200 electrons with TurboDAQ
• ToT tuned to 30 cycles at 20000 electrons
• Framework with STcontrol now in place
• probably still some more bug
• would be good to check the result with the scan experts
CORBA Problems
Scan Status 06/12/10 M. WittgenPage 5
• Histograms are published to histogram server
• takes several minutes if all histograms are sent
• rate in the order of ten per second
• 101 bins x (3x ToT + 3 BCID + OCC) = 707 histograms
• Alternative (faster) method: download from RCE
• CORBA crashes (timeout?) when more then a certain amount (bins>50) of histograms present
• For now workaround in STcontrol
• download one-bye-one
• reasonably fast
TurboDAQ/STcontrol GDAC Tune
Scan Status 06/12/10 M. WittgenPage 6
TurboDAQ/STcontrol FDAC Tune
Scan Status 06/12/10 M. WittgenPage 7
GDAC FDAC Tune
Scan Status 06/12/10 M. WittgenPage 8
IF Tune
Scan Status 06/12/10 M. WittgenPage 9
Analog Scan ToT=30 @ 2000 e-
Scan Status 06/12/10 M. WittgenPage 10
ToT vs charge calibration
Scan Status 06/12/10 M. WittgenPage 11