SafeDispatch TRBO REPEATER Gateway - SafeMobileportal.safemobile.com/upload/safedispatch/...4.1 MNIS...

11
SafeMobile offers a world of wireless applications that help organizations better manage their mobile assets, fleet and personnel. For more information, see www.safemobile.com . Installation and Configuration Guide SafeDispatch TRBO REPEATER Gateway

Transcript of SafeDispatch TRBO REPEATER Gateway - SafeMobileportal.safemobile.com/upload/safedispatch/...4.1 MNIS...

  • SafeMobile offers a world of wireless applications that help organizations better manage their mobile assets, fleet and personnel. For more information, see www.safemobile.com.

    Installation and Configuration Guide

    SafeDispatch

    TRBO REPEATER

    Gateway

  • Copyright © SafeMobile 2015. All rights reserved 1

    SafeDispatch Installation and Configuration Guide

    Contents

    1 System diagram and overview ...................................................................................... 2

    2 Installing the TRBO REPEATER Gateway ........................................................................ 3

    3 Motorola CPS – Repeater configuration .......................................................................... 4

    4 MNIS and DDMS Motorola Software .............................................................................. 6

    4.1 MNIS General Settings ...................................................................................... 6

    4.2 MNIS Conventional / IP Site Connect Setup ........................................................ 6

    5 Register the gateway application .................................................................................. 8

    6 Gateway User Interface ............................................................................................... 9

  • Copyright © SafeMobile 2015. All rights reserved 2

    SafeDispatch Installation and Configuration Guide

    1 System diagram and overview

    The below diagram describes the SafeDispatch system deployment layout using one Server computer and two client computers, connected via IP to a Motorola Repeater.

    Figure 1 [System Diagram]

  • Copyright © SafeMobile 2015. All rights reserved 3

    SafeDispatch Installation and Configuration Guide

    2 Installing the TRBO REPEATER Gateway

    From the installation wizard select from the gateway type dropdown "TRBO_REPEATER"

    Figure 2 [SafeDispatch Installation Form]

    During the installation, a driver window will prompt for confirmation, this is the driver for the USB 3000 voice decoder device.

    Figure 3 [USB3000 Driver Installation]

  • Copyright © SafeMobile 2015. All rights reserved 4

    SafeDispatch Installation and Configuration Guide

    3 Motorola CPS – Repeater configuration

    Make sure you have the latest Motorola CPS release installed. Open Motorola CPS

    o Enter Expert view: from View menu and Click “Expert”

    Figure 4 [Motorola CPS – Expert View]

    Read the Motorola Master Repeater by clicking the “Read” button

    First ensure the repeater has the required licenses activated o Network Application Interface Voice (optional, required for Call Recordings) o Network Application Interface Data (required for GPS and SMS)

    Figure 5 [Motorola CPS – Device Features]

  • Copyright © SafeMobile 2015. All rights reserved 5

    SafeDispatch Installation and Configuration Guide

    NOTE: Ensure each Repeater in your radio network has a unique radio ID.

    Setup the repeater in Master configuration mode from Link Establishment menu o This will allow the assignment of Static IP address

    Setup your Master Repeater with a Static IP address on your local network o From Network menu deselect “DHCP” o Enter a Static IP address (ensure it is not used by other devices on the LAN)

    Figure 6 [Motorola CPS – Network]

    NOTE: The system will only connect to a Master Repeater (ensure your repeater is in Master configuration, from the Link Establishment menu).

  • Copyright © SafeMobile 2015. All rights reserved 6

    SafeDispatch Installation and Configuration Guide

    4 MNIS and DDMS Motorola Software

    To run this gateway you must install and configure the MNIS and DDMS Motorola software No changes are required in DDMS Software if it runs on the same PC with MNIS All repeaters require MNIS Data for the GPS traffic If voice recordings are used then MNIS Voice license is also required For voice recordings a USB 3000 decoder device is required

    4.1 MNIS General Settings

    Configure the MNIS Application ID in the MNIS Software, this ID must be unique in the Radio Network and represents the Radio ID where the subscriber radios will send ARS and GPS data

    Figure 7 [MNIS – General Settings]

    4.2 MNIS Conventional / IP Site Connect Setup

    Configure the Master Repeater IP Address Configure the Master Repeater UDP Port Enable the in use Time Slots

  • Copyright © SafeMobile 2015. All rights reserved 7

    SafeDispatch Installation and Configuration Guide

    Figure 8 [MNIS – Master Repeater IP and UDP Port]

    Figure 9 [MNIS – Conventional Time Slots]

  • Copyright © SafeMobile 2015. All rights reserved 8

    SafeDispatch Installation and Configuration Guide

    5 Register the gateway application

    Open the SafeMobile Administrative Module and select the Gateway tab

    Figure 10 [SafeMobile Administrative Module – Gateway registration tab]

    Under the Add new Gateway column: o Enter the IP address of the computer running the TRBO REPEATER gateway application o Enter the Peer ID, this must be a unique id in your radio system

    Under the Add new Radio Gateway column: o Enter the Master Repeater IP address, also defined in MNIS Software

    Figure 8 [MNIS – Master Repeater IP and UDP Port] o Assign a Name to this entry o Select the repeater Time Slot o Select if it is Voice enabled or no

  • Copyright © SafeMobile 2015. All rights reserved 9

    SafeDispatch Installation and Configuration Guide

    6 Gateway User Interface

    The Repeater gateway has additional settings that must match the MNIS and Repeater configuration

    Figure 11 [SafeMobile MotoTRBO Repeater Gateway software application]

    Master Repeater Port is default 50000, this value must match the Repeater and MNIS port number configuration if changed

    Network Type must match your Radio Network Type. The default value is Single (Conventional) / IP Site Connect

  • Copyright © SafeMobile 2015. All rights reserved 10

    SafeDispatch Installation and Configuration Guide

    Figure 1 [System Diagram] ........................................................................................................... 2

    Figure 2 [SafeDispatch Installation Form] ...................................................................................... 3

    Figure 3 [USB3000 Driver Installation] ........................................................................................... 3

    Figure 4 [Motorola CPS – Expert View] .......................................................................................... 4

    Figure 5 [Motorola CPS – Device Features] .................................................................................... 4

    Figure 6 [Motorola CPS – Network] ............................................................................................... 5

    Figure 7 [MNIS – General Settings] ............................................................................................... 6

    Figure 8 [MNIS – Master Repeater IP and UDP Port] ...................................................................... 7

    Figure 9 [MNIS – Conventional Time Slots] .................................................................................... 7

    Figure 10 [SafeMobile Administrative Module – Gateway registration tab] ......................................... 8

    Figure 11 [SafeMobile MotoTRBO Repeater Gateway software application] ....................................... 9

    file:///C:/Users/SafeMobile%20AIR/Desktop/SafeDispatch7_TRBO_REPEATER_Configuration_EN.docx%23_Toc488148167