s1240 Ground Floor - Amazon Web Services
Transcript of s1240 Ground Floor - Amazon Web Services
WCOFFICE
OFFICEOFFICE
WC
CLASS
STAFF
ROOM
FEMALE
MALE
OFFICE
DINING
LOBBY
STUDENT
SERVICES
FIRST
AID
HEAD TEACHER
EXISTING
HEAD
PA EXISTING
Wash
Room
MEETING
ROOM
EXISTING
RECEPTION
DRY
STORE
DISABLED
WC
BIN
STORE
PLANT ROOM
EXISTING
STORE
OFFICE
WC
STOREWORKSHOP
ELECTIC
SUB-STATION
OFFICE
STAFF
99.110 SSL
99.410
99.110 SSL
99.110 SSL
99.620
99.620 SSL
99.630 SSL
99.640
99.590
99.620 SSL
99.130 SSL
99.110 SSL
99.110 SSL
99.110 SSL
99.110 SSL
99.620
99.620
99.590
99.560 GL
99.120 FFL EXG
99.620 SSL
STORE
KITCHEN
EXISTING
OFFICE
DRY
STORE
Cold Room
HEAD TEACHERS
DINING AREA
EXISTING
PT
A K
IT
CH
EN
SCIENCE
BLOCK
EXISTING
MAIN
BLOCK
EXISTING
Computer Suite 43
Entrance
Lobby
Classroom 48
Lobby
Entrance
Corridor
Library and
IT suite
EBD Suite
SENCO room
SEN main
group room 49
SEN group
room
EBD Suite
StoreComm's
D08
D18
Library and
IT suite
CENTRAL
PLAY
AREA
MAIN HALL 615m2
EXISTING
SPORTS
HALL
STAGE
100m2
GROUND FLOOR 85m2
STAIRS
STAIRS
GROUND FLOOR
SCIENCE BLOCK
PLANT
ROOM
STORE
CIRCULATION
110m2
LIFT
FACADE -
NATURAL
DAYLIGHT
FACADE -
NATURAL
DAYLIGHT
FACADE -
NATURAL
DAYLIGHT
FACADE -
NATURAL
DAYLIGHT
VEHICLE
ACCESS
VEHICLE
ACCESS
External
Lobby
GROUND FLOOR
LABORATORY 85m2
GROUND FLOOR
LABORATORY 82m2
GROUND FLOOR
LABORATORY 76m2
LIFT
LOBBY
EXTG
CHANGE
MALE
46m2
CHANGE
FEMALE
46m2
EL
EC
TR
IC
S
UN
DE
R
41m Approx.
27.35
DINING
HALL
EXISTING
CHANGE
AREAS
EXISTING
LIBRARY
EXISTING
COLD
STORE
EXTG
COLD
STORE
EXTG
VEHICLE
ACCESS
0 1 2 3 4 5 10 15 20 30
do not scale from this drawing
architects
clark birch perkins
44 The Ropewalk Nottingham NG1 5DW
t: 0115 9481144 f: 0115 9580976
construction managementinteriors
10/11/17
Revision
-
1:200
Original sheet size A1
rev. date content by
Project
Drawing Title
Scale
Approved
Date
Status
Drawing Number
S1240 A 204
Reproduction subject to Copyright
1. THIS IS AN A1 DRAWING, IF REPRODUCED IN
ANY OTHER FORMAT THE SCALE SHOWN
WILL BE INCORRECT.
2. DO NOT SCALE OFF THIS DRAWING.
3. ANY AMBIGUITIES, OMISSIONS AND ERRORS,
OR INCONSISTENCIES WITH OTHER
DOCUMENTS, ON THIS DRAWING SHOULD BE
NOTIFIED IMMEDIATELY TO THE ARCHITECT
BEFORE THE COMMENCEMENT OF WORKS
ON SITE.
4. ALL DIMENSIONS ARE IN MILLIMETRES
UNLESS OTHERWISE STATED.
5. ALL DIMENSIONS, UNLESS OTHERWISE
STATED, ARE TO THE FACE OF UNFINISHED
MASONRY WALLS OR TO THE FINISHED
PLASTER FACE OF STUD PARTITIONS.
6. ALL DIMENSIONS ARE TO BE CHECKED ON
SITE. ANY DISCREPANCIES ARE TO BE
NOTIFIED IMMEDIATELY TO THE ARCHITECT
BEFORE THE COMMENCEMENT OF WORKS
ON SITE.
7. ALL LEVELS ARE IN METRES UNLESS
OTHERWISE STATED.
8. THIS DRAWING IS TO BE READ IN
CONJUNCTION WITH ALL OTHER RELEVANT
DRAWINGS AND SPECIFICATIONS FOR THIS
PROJECT AND APPARENT INCONSISTENCIES
BROUGHT TO THE ATTENTION OF THE
ARCHITECT.
NOTES
Drawn CheckedRR
xx
xx
Information
Fernwood School
Increase in Capacity
Block Plan Additional Classrooms
and Main Hall - Ground Floor