S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...

10

Transcript of S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...

Page 1: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
1
AutoCAD SHX Text
CVR
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
DRAWING LIST CVR - COVER SHEET A-0 - ARCH. NOTES A-1 - FLOOR PLAN A-2 - ELEVATIONS A-3 - LIFE SAFETY PLAN S-0 - STRUCTURAL NOTES S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING DETAILS E-1 - ELECTRICAL PLAN
AutoCAD SHX Text
ENGINEERING PLANS FOR PIRATE BASEBALL EXERCISE ROOM HICKORY STREET FERNANDINA BEACH, FLORIDA FOR NASSAU COUNTY SCHOOL BOARD PREPARED BY: GILLETTE AND ASSOCIATES, INC. CERTIFICATE OF AUTHORIZATION NO.: 9332 20 SOUTH 4TH STREET FERNANDINA BEACH, FL 32034 PHONE: 904-261-8819 ASA R. GILLETTE, P.E. FL P.E. NO. 56177 FLORIDA BUILDING CODE PARAMETERS: OCCUPANCY CLASSIFICATION: EDUCATIONAL, GROUP E SUB CLASSIFICATION: EXERCISE ROOM DUGOUT EXPANSION CONSTRUCTION: CONCRETE & METAL CONSTRUCTION TYPE: II-A OCCUPANT LOAD: EXERCISE ROOM: 50 S.F./OCC. (GROSS) EXPANSION AREA: 1404 S.F. PROPOSED OCCUPANT LOAD: (1404/50) = 28 OCCUPANTS SPACE PARAMETERS: EXIST. DUGOUT AREA: 992 SQ. FT. DUGOUT EXPANSION AREA: 1,404 SQ. FT. USE: PUBLIC SCHOOL SPORTS FACILITY REFERENCES: 1) FLORIDA BUILDING CODE, 2020 (7TH ED.) 2) ASCE 7-16 3) AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 4) NATIONAL ELECTRIC CODE (NEC), 2014 5) FLORIDA FIRE PREVENTION CODE, 2020 (7TH ED.)
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
Page 2: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
3. FIRE EXTINGUISHERS TO BE FURNISHED BY CONTRACTOR IN ACCORDANCE WITH LIFE SAFETY PLAN AND DRAWINGS (COORDINATE W/SUBCONTRACTORS). 4. ALL ELECTRICAL WIRING TO BE IN CONDUIT. ALL CONDUIT TO BE CONCEALED. 5. EXIT SIGNS - PER CODE REQUIREMENTS, DUAL VOLTAGE, BATTERY OPERATED, LITHONIA OR EQUAL. 6. EMERGENCY BATTERY UNITS - AS REQUIRED BY CODE. LITHONIA UL-4 OR EQUAL. SEE ELECTRICAL DRAWINGS. 7. SEE INTERIOR FINISH SCHEDULE FOR CEILING AND WALL TYPES. 8. ALL FURNITURE (CHAIRS, DESKS, ETC), TELEVISION MONITORS, BENCHES, VENDING MACHINES, AND COMPUTER EQUIPMENT SHOWN ON PLANS TO BE PROVIDED AND INSTALLED BY OWNER. CONTRACTOR TO COORDINATE AS JOB PROGRESSES. 9. ALL SPECIALTY ITEMS (SHELVES, DISPLAYS, ETC) TO BE FABRICATED IN PLACE BY THE CONTRACTOR AND COORDINATED WITH THE OWNER. 10. ALL RETAIL COUNTER TOPS AND CABINETRY TO BE FURNISHED AND INSTALLED BY THE CONTRACTOR WITH COORDINATION BY THE OWNER TO MEET USE.
AutoCAD SHX Text
FIRE RATED ASSEMBLIES 1. STUD SYSTEM TO BE AS STATED ON DRAWINGS. 2. ALL JOINTS TO RECEIVE JOINT TAPE AND COMPOUND IN ACCORDANCE WITH UNDERWRITER'S LABORATORY. 3. ALL DOORS WHICH RESIDE IN 1-HOUR RATED ASSEMBLIES SHALL HAVE A 20 MINUTE RATING. 4. ALL PENETRATIONS TO BE SEALED WITH FIRE RATED CAULKING. PENETRATIONS AS FOLLOWS: - PLUMBING/CONDUIT (WHERE APPLICABLE): UTILIZE A 2-HR FIRE RATED SLEEVE AND SEAL ANNULAR SPACE WITH FIRE RATED CAULKING EQUIVALENT TO A 2-HR RATING. - ELECTRICAL BOXES (WHERE APPLICABLE): LIMITED TO STEEL MATERIAL AND 16 SQUARE INCHES, WITH AN ANNULAR SPACE BETWEEN THE BOX NOT TO EXCEED ". 18". BOXES ON THE OPPOSITE SIDE OF THE RATED WALL SHALL NOT ALIGN. - HVAC DUCTWORK (WHERE APPLICABLE): PENETRATIONS TO HAVE 2-HR FIRE RATED DAMPERS.
AutoCAD SHX Text
GENERAL NOTES 1. ALL DOOR HARDWARE TO BE ADA COMPLIANT. 2. ALL INTERIOR SIGNAGE TO INSTALLED PER FBC 11-4.30 SIGNAGE. SIGNS SHALL BE INSTALLED ON WALLS ADJACENT TO LATCH SIDE OF DOOR. MOUNTING HT SHALL BE 60" AFF TO CENTERLINE OF SIGN. FACILITIES AND ELEMENTS REQUIRED TO BE IDENTIFIED AS ACCESSIBLE SHALL USE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY.
AutoCAD SHX Text
WINDOWS AND DOORS 1. STANDARDS/LABELING: EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING LABORATORY, AND SHALL BE LABELED WITH AN APPROVED LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT CERTIFICATION AGENCY AND FLORIDA BUILDING CODE COMPLIANCE. 2. DESIGN PRESSURE PERFORMANCE TO BE IN ACCORDANCE WITH WIND LOAD PARAMETERS LISTED ON THE COVER SHEET. 3. ALL EXTERIOR DOOR AND WINDOW ASSEMBLIES SHALL BE ANCHORED IN ACCORDANCE W/THE PUBLISHED MANUFACTURER'S RECOMMENDATIONS TO ACHIEVE MOUNTING STRENGTH FOR THE DESIGN PRESSURE SPECIFIED. 4. ALL NEW WINDOWS TO BE DOUBLE PANE (INSULATED), 14" THICK GLASS. FRAMING TO BE ENERGY EFFICIENT VINYL OR SIMILAR. 5. EXTERIOR DOORS TO BE INSULATED AND MANUFACTURED IN ACCORDANCE WITH CURRENT BUILDING CODE AND MEET CURRENT WIND LOADS LISTED ON THE COVER SHEET. 6. INTERIOR DOORS DO NOT REQUIRE AN STC RATING. 7. FINAL DOOR HARDWARE TO BE DETERMINED BY OWNER. 8. ALL WINDOW AND DOOR SIZES SHOWN ON THE PLANS ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ACTUAL DIMENSIONS AND USE STOCK SIZES WHENEVER POSSIBLE. ALLOW FOR ADDITIONAL BUCKING IN R.O. SIZES WHERE POSSIBLE IN MASONRY WALLS. 9. INSULATE AROUND NEW DOORS AND WINDOWS W/ POLYFOAM OR SIMILAR.
AutoCAD SHX Text
WALLS AND TRIM 1. SEE PLANS AND/OR OWNER FOR FLOOR, WALL AND CEILING FINISHES. 2. ALL NEW INTERIOR WALLS TO RECEIVE " GYP BD, 12" GYP BD, SCREWED INTO PLACE PER INDUSTRY STANDARDS WITH SMOOTH FINISH. ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND (2) SEPARATE COATS OF JOINT COMPOUND APPLIED OVER INTERIOR ANGLES. ALL JOINT COMPOUND TO BE FREE OF TOOL MARKS AND RIDGES. 3. INSULATE INTERIOR WALLS WITH SOUND BATTS WHERE SHOWN ON THE FLOOR PLAN. 4. NEW EXTERIOR WINDOW AND DOOR TRIMS TO MATCH EXISTING IN FINISH APPEARANCE. 5. INTERIOR, NON LOAD BEARING WALL CONSTRUCTION TO BE 2X4 WOOD STUDS OR EQUIVALENT LIGHT GAGE FRAMING. 6. ALL INTERIOR WALLS TO HAVE A CLASS B FINISH (FLAME SPREAD INDEX 26-75, SMOKE SMOKE DEVELOPED INDEX 0-450). 7. SUPPLY SAMPLES AS REQUIRED BY OWNER FOR APPROVAL PRIOR TO PROCUREMENT.
AutoCAD SHX Text
WATERPROOFING & PAINTING 1. EXTERIOR JOINT SEALERS AND CAULKING TO BE APPLIED AT ALL JOINTS TO ACHIEVE MOISTURE AND AIR-TIGHT JOINTS. THE FOLLOWING ARE RECOMMENDED WITH EQUALS ACCEPTABLE: URETHANES (TO BE COVERED): URETHANES (TO BE COVERED): (TO BE COVERED): - SIKAFLEX 15LM (LOW MODULUS) - TREMCO VULKEM 921 (LOW MODULUS) SILICONES (USE PRIMER AND SURFACE PREP AS SILICONES (USE PRIMER AND SURFACE PREP AS (USE PRIMER AND SURFACE PREP AS REQ'D): - DOW CORNING 795 - PECORA 795 - TREMCO SPECTUM II - SIKA 2. EXPOSED BLOCK PAINT SYSTEM TO BE THOROCOAT WATER-BASED, HIGH-BUILD, ACRYLIC WATERPROOF COATING (OR EQUAL) TO BE SUPPLIED WITH A 10-YEAR MANUFACTURER'S WARRANTY. SEAL PRIOR WITH THORO CM PRIMER (OR EQUAL). SEAL ALL CRACKS AND JOINTS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS PRIOR TO PAINTING. 3. RECOMMENDED JOINT CAULKING PARAMETERS (VERIFY WITH MANUFACTURER'S LITERATURE): JOINTS " TO " 14" TO " 12" WIDE, WIDTH TO DEPTH TO BE EQUAL. JOINTS " WIDE 12" WIDE OR GREATER SHOULD HAVE A SEALANT DEPTH OF ". 12". MINIMUM JOINT SIZE TO BE "X ". 14"X ". 14". 4. PAINTING OF SUBSTRATES AS FOLLOWS: - EXPOSED 8X16 EXTERIOR CMU BLOCK: EXPOSED 8X16 EXTERIOR CMU BLOCK: : ELASTOMERIC PAINT SYSTEM (OR EQUAL) WITH FINAL COLOR TO BE DETERMINED BY OWNER. (1) COAT PRIMER, (1) COAT SEALER. CLEAN AND PREP SURFACE PER MANUFACTURER'S SPECIFICATIONS. - STEEL (SHOP PRIMED): TOUCH UP WITH ZINC STEEL (SHOP PRIMED): TOUCH UP WITH ZINC : TOUCH UP WITH ZINC CHROMATE PRIMER, (2) COATS ALKYD ENAMEL. - EXISTING WOOD EXTERIOR: PRESSURE CLEAN SURFACE AND REMOVE DEBRIS AND LOOSE MATERIAL, (1) COAT OIL BASED/ALKYD PRIMER/SEALER, (2) COATS ACRYLIC. FINAL COLORS BY OWNER. - GYPSUM BOARD (WALLS): SAND SMOOTH, DUST GYPSUM BOARD (WALLS): SAND SMOOTH, DUST : SAND SMOOTH, DUST AND CONDITION TO RECEIVE FINISH; (1) COAT LATEX WALL PRIMER, (2) COATS FLAT OR SATIN ACRYLIC. SEE INTERIOR FINISH SCHEDULE FOR COLORS.
AutoCAD SHX Text
LIGHT GAGE FRAMING 1. LIGHT GAGE FRAMING ACCEPTABLE IN LIEU OF WOOD STUDS. ALL WORK SHALL CONFORM TO THE LATEST ADDITION OF THE AISI SPECIFICATION FOR THE DESIGN OF COLD ROLLED STEEL MEMBERS. 2. PRIOR TO FABRICATION OF FRAMING, THE CONTRACTOR SHALL FIELD VERIFY ALL WALL LAYOUT AND REQUIRED INFORMATION. 3. BRIDGING INSTALLATION: INSTALL SOLID BRIDGING AS REQUIRED. 4. STUDS SHALL BE PRODUCT OF DIETRICH INDUSTRIES OR EQUAL. 5. METAL WALL STUD SHEETS SHALL COMPLY WITH ASTM A1003 / A1003M 6. INTERIOR, NON-STRUCTURAL, METAL WALL STUDS SHALL CONFORM TO ASTM C645-08a, "STANDARD SPECIFICATIONS FOR NONSTRUCTURAL STEEL FRAMING MEMBERS." 7. INTERIOR, NON-STRUCTURAL, METAL WALL STUDS SHALL CONFORM TO ASTM C754-08, "STANDARD SPECIFICATION FOR INSTALLATION OF STEEL FRAMING MEMBERS". 8. MASONRY FURRING, IF REQUIRED, TO RECEIVE SINGLE LEG (Z-FURRING) OR DOUBLE LEG (HALF CHANNEL) GALV. STEEL STUD, 18 MIL THICK (25ga). INTERIOR WALL STUDS TO RECEIVE DOUBLE LEG CHANNELS 30 MIL. (20 ga.) GALV. STEEL STUDS.
AutoCAD SHX Text
ALLOWANCES 1. COSTS INCLUDED IN ALLOWANCES: - DESIGN, MATERIALS & INSTALL: COST OF DESIGN TO CONTRACTOR; COST OF PRODUCT TO CONTRACTOR DELIVERED AT THE SITE, INSTALLATION, FINISHING, AND ALL REQUIRED TAXES, LESS APPLICABLE TRADE DISCOUNTS. COST TO INSTALL IS PART OF ALLOWANCE NUMBER. - MATERIALS AND INSTALL: COST OF PRODUCT TO CONTRACTOR DELIVERED AT THE SITE, INSTALLATION, FINISHING, AND ALL REQUIRED TAXES, LESS APPLICABLE TRADE DISCOUNTS. COST TO INSTALL IS PART OF ALLOWANCE NUMBER. - MATERIALS ONLY: COST OF PRODUCT TO CONTRACTOR DELIVERED AT THE SITE, ALL REQUIRED TAXES, LESS APPLICABLE TRADE DISCOUNTS; INSTALLATION COST SHALL BE INCLUDED IN THE BASE BID. 2. COSTS NOT INCLUDED IN ALLOWANCES: CONTRACTOR'S COST FOR UNLOADING, STORING AND HANDLING AT THE SITE, OVERHEAD, PROFIT, AND OTHER EXPENSES CONTEMPLATED FOR STATED ALLOWANCE AMOUNTS SHALL BE INCLUDED IN THE CONTRACT BASE BID SUM AND NOT IN THE ALLOWANCES. 3. FUNDS: DIFFERENCE IN COST WILL BE ADJUSTED BY CHANGE ORDER. CONTRACTOR TO COORDINATE ADJUSTMENT METHOD W/ OWNER PRIOR TO CONTRACT. 4. CASH ALLOWANCE LIST: CONTRACTOR TO PROVIDE ITEMIZED PRICE BREAKDOWN AT THE TIME OF BID FOR OWNER'S EVALUATION. IN WRITING, LIST PRICES IN SAME ORDER AND BY CATEGORY FOR OWNER'S REVIEW.
AutoCAD SHX Text
5. 1-HR STUD FIRE WALLS: 2X4 OR 2X6 METAL STUDS N.T.E. 16" O.C. W/MIN 3" THICK MINERAL WOOL INSULATION BATTS WITH ONE SHEET OF " THICK, TYPE-X, GYPSUM BOARD ON BOTH 58" THICK, TYPE-X, GYPSUM BOARD ON BOTH SIDES. WALL TO BE CONTINUOUS TO ROOF SYSTEM OR RATED CEILING. ALL JOINTS TO RECEIVE JOINT TAPE AND COMPOUND IN ACCORDANCE WITH UNDERWRITER'S LABORATORY. ALL PENETRATIONS PER ITEM 4 ABOVE. INSTALL SECOND LAYER OF GYP. BD. 90-DEG. TO FIRST LAYER AND ENSURE STAGGERING OF JOINTS 6. CMU WALLS, UNFILLED, CONSIDERED 2-HR RATED PARTITION AND SATISFIES A 1-HR REQUIRED SEPERATION FOR STORAGE USE GREATER THAN 200 S.F.
AutoCAD SHX Text
CEILING SYSTEM: OPTION #1: 12" GYPSUM BOARD, PAINTED INTERIOR FINISH AS NOTED ON PLANS. MATERIAL SHALL BE CLASS B (F.S. INDEX 26-75-S-D 0-450 FINAL COLOR T.B.D. OPTION #2: GENERAL AREA ACOUSTIC CEILING GRID SYSTEM 2'X4' GRID PATTERN. INTERIOR FINISH MATERIAL SHALL BE CLASS B (F.S. INDEX 26-75-S-D 0-450FINAL COLOR T.B.D.
AutoCAD SHX Text
METAL ROOF PANEL SYSTEM: METAL ROOF PANEL SYSTEMS TO COMPLY WITH SECTION 1507.4 OF THE F.B.C., 2020 MINIMUM DECKING THICKNESS TO BE ". 12". THE MINIMUM SLOPE FOR LAPPED, NONSOLDERED SEAM METAL ROOF PANELS WITH APPLIED LAP SEALANT SHALL BE ONE-HALF UNIT VERTICAL IN 12 UNITS HORIZONTAL (4% SLOPE). LAP SEALANTS SHALL BE APPLIED IN ACCORDANCE WITH THE APPROVED MANUFACTURER'S INSTRUCTION. THE MINIMUM SLOPE FOR STANDING-SEAM METAL ROOF PANEL SYSTEMS SHALL BE ONE-QUARTER UNIT VERTICAL IN 12 UNITS HORIZONTAL. ROOF UNDERLAYMENT SHALL COMPLY WITH AND BE INSTALLED PER SECTION 1507.1.1, F.B.C., 2020. DOUBLE UNDERLAYMENT REQUIRED.
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
2
AutoCAD SHX Text
A-0
AutoCAD SHX Text
ARCH. NOTES
AutoCAD SHX Text
1
Page 3: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
FLOOR PLAN SCALE: " = 1'-0"14" = 1'-0"
AutoCAD SHX Text
EXISTING STORAGE
AutoCAD SHX Text
EXISTING HOME DUGOUT
AutoCAD SHX Text
EXISTING DOUBLE DOORS
AutoCAD SHX Text
CUT EXISTING BLOCK WALL FOR NEW 1-HR RATED DOOR (EXIST. STG GREATER THAN 200 S.F.)
AutoCAD SHX Text
EXISTING BATHROOMS
AutoCAD SHX Text
A/C
AutoCAD SHX Text
EXISTING ELECTRIC
AutoCAD SHX Text
3068
AutoCAD SHX Text
A/C
AutoCAD SHX Text
WEIGHT ROOM 613 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
WARM-UP AND GATHERING ROOM 714 SF
AutoCAD SHX Text
N
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
2868
AutoCAD SHX Text
3068
AutoCAD SHX Text
2x4 METAL STUDS N.T.E. 16" O.C.
AutoCAD SHX Text
HSS4X4X (TUBE 316 (TUBE STEEL, 4 PL.)
AutoCAD SHX Text
(2)3068
AutoCAD SHX Text
NEW 8" MASONRY WALL W/ 1-#5 VERT. AT EA. SIDE OF OPENINGS & CORNERS (TYP)
AutoCAD SHX Text
OPEN FACE SIDE OF EXIST. DUGOUT
AutoCAD SHX Text
EXIST. CMU WALL, UNFILLED (2-HR RATED PARTITION)
AutoCAD SHX Text
EXIST. GANG BATHROOMS APPROXIMATELY 65-FT SOUTH VIA CONCRETE SIDEWALK
AutoCAD SHX Text
EXIST. CMU WALL, UNFILLED (2-HR RATED PARTITION)
AutoCAD SHX Text
%%UTYPICAL INTERIOR WALL SECTION
AutoCAD SHX Text
ROOF JOIST, SEE PLANS
AutoCAD SHX Text
2x4 METAL STUDS AT 16" O.C. W/ " GYP BOARD EACH FACE12" GYP BOARD EACH FACE
AutoCAD SHX Text
NEW CONCRETE SLAB
AutoCAD SHX Text
2x4 SILL PLATE ANCHORED TO CONCRETE SLAB W/CONC. NAILS
AutoCAD SHX Text
2x4 TOP PLATE
AutoCAD SHX Text
6"
AutoCAD SHX Text
CEILING SUPPORT CABLE TO ROOF JOISTS
AutoCAD SHX Text
DROP DOWN ACOUSTIC CEILING
AutoCAD SHX Text
MIN. R-13 BATT INSULATION OR EQUAL, AT UNDERSIDE OF ROOF.
AutoCAD SHX Text
(SCALE: 1/4"=1'-0")
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
3
AutoCAD SHX Text
A-1
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
Page 4: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
EXISTING DUGOUT
AutoCAD SHX Text
PROPOSED ADDITION
AutoCAD SHX Text
EXISTING ROOF STRUCTURE TO BE REMOVED
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
NEW ROOF FRAMING, SEE PLANS
AutoCAD SHX Text
NORTH ELEVATION
AutoCAD SHX Text
SOUTH ELEVATION
AutoCAD SHX Text
WEST ELEVATION
AutoCAD SHX Text
EXISTING DUGOUT
AutoCAD SHX Text
PROPOSED ADDITION
AutoCAD SHX Text
EXISTING ROOF STRUCTURE TO BE REMOVED
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
NEW ROOF, SEE SHEET S-1 AND A-0
AutoCAD SHX Text
NEW METAL ROOF
AutoCAD SHX Text
NEW LAPPED, NON-SOLDERED METAL ROOF. SEE F.P.A. SUBMITTAL. ANCHOR PER MANUF.
AutoCAD SHX Text
EXISTING ELECTRIC PANEL
AutoCAD SHX Text
EXISTING DUGOUT BEGINS 26' EASTWARD
AutoCAD SHX Text
NEW ROOF FRAMING, SEE PLANS
AutoCAD SHX Text
NEW METAL ROOF
AutoCAD SHX Text
PROPOSED ADDITION BEGINS 8' NORTHWARD
AutoCAD SHX Text
0.5/12
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
4
AutoCAD SHX Text
A-2
AutoCAD SHX Text
ELEVATIONS
AutoCAD SHX Text
2
AutoCAD SHX Text
2
Page 5: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
A/C
AutoCAD SHX Text
WEIGHT ROOM 613 SF
AutoCAD SHX Text
WARM-UP AND GATHERING ROOM 714 SF
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
2A
AutoCAD SHX Text
1B
AutoCAD SHX Text
2B
AutoCAD SHX Text
2B
AutoCAD SHX Text
1B
AutoCAD SHX Text
1A
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
EGRESS TRAVEL DISTANCES: PATH 1A: 51-FT 51-FT PATH 1B: 62-FT 62-FT PATH 2A: 29-FT 29-FT PATH 2B: 73-FT 73-FT PATH 3: 69-FT 69-FT COMMON PATH: 51-FT (PATHS 1 & 2 ONLY)
AutoCAD SHX Text
EXISTING DUGOUT
AutoCAD SHX Text
EXISTING STORAGE ROOM (420 S.F.)
AutoCAD SHX Text
NEW 1-HR RATED DOOR
AutoCAD SHX Text
EXIST. CMU WALL, UNFILLED (2-HR RATED PARTITION)
AutoCAD SHX Text
TRAVEL PATH (TYP)
AutoCAD SHX Text
EXIT SIGN WITH EMERGENCY LIGHT PACK (TYP)
AutoCAD SHX Text
3
AutoCAD SHX Text
OPEN FRONT
AutoCAD SHX Text
CLASS 2-A FIRE EXTINGUISHER (MAX FLOOR AREA 1,500 S.F.)
AutoCAD SHX Text
COMMON PATH OF TRAVEL (51-FT)
AutoCAD SHX Text
3
AutoCAD SHX Text
LIFE SAFETY PLAN SCALE: " = 1'-0"14" = 1'-0"
AutoCAD SHX Text
%%UEXIT DISCHARGE & EGRESS PARAMETERS:
AutoCAD SHX Text
%%UEGRESS DISTANCE & CAPACITY:
AutoCAD SHX Text
%%UCALCULATED EGRESS PARAMETERS:
AutoCAD SHX Text
%%ULIFE SAFETY PLAN NOTES:
AutoCAD SHX Text
- EGRESS BEGINNING POINTS SHOWN ATTEMPT TO REPRESENT A MAXIMUM POINT THAT WOULD BE CONSIDERED COMMON. - EGRESS PATHS SHOWN ATTEMPT TO REPRESENT A REALISTIC MEANS TO AN EXIT (AS OPPOSED TO AN "AS THE CROW FLIES" DIRECT ROUTE). - EGRESS DISTANCES LISTED ON THE PLAN REPRESENT THE TOTAL EGRESS LENGTH FROM TOTAL EGRESS LENGTH FROM EGRESS LENGTH FROM THAT POINT TO THE EXIT POINT NOTED. - ALL PATHS ALSO CONTAIN SECONDARY MEANS THROUGH ADJACENT SPACE, WHICH MAY NOT BE SHOWN ON THE PLAN. - DISCHARGE INTO RATED CORRIDOR (IF APPL.) MUST BE LESS THAN 75-FT TRAVEL DISTANCE. - FIRE EXTINGUISHERS SHOWN ARE BASED ON CLASS "A" FIRE HAZARDS FOR ORDINARY (MODERATE) HAZARD OCCUPANCY (FBC 2020, TABLE 906.3(1). MAXIMUM FLOOR AREA 1,500 S.F. AND MAX. TRAVEL DISTANCE TO EXTINGUISHER OF 75-FEET. NO FLAMMABLE OR COMBUSTIBLE LIQUIDS ANTICIPATED.
AutoCAD SHX Text
- SPACE IS NOT PROTECTED BY AN AUTOMATIC FIRE PROTECTION SYSTEM. - CONSTRUCTION CLASSIFICATION TYPE V, UNPROTECTED. - ALL EGRESSES SHOWN ON THE PLANS MEET OR EXCEED THE REQUIRED DISTANCES AND CAPACITIES AS SET FORTH BELOW.
AutoCAD SHX Text
MAX EXIT ACCESS TRAVEL DISTANCE - FBC 2020, TABLE 1017.2: - GROUP E: 200-FT WITHOUT FIRE SPRINKLER MAX COMMON PATH OF EGRESS TRAVEL DISTANCE W/ ONE EXIT - FBC 2020, TABLE 1006.2.1: - 75-FT WITHOUT FIRE SPRINKLER DOORS (MAN-TYPE): 0.2" PER OCCUPANT (FBC 2020, SECTION 1005.3.2)
AutoCAD SHX Text
MINIMUM EGRESS WIDTH: - 3068 DOOR = 36" 36" / 0.2 = 180 OCCUPANTS - 2868 DOOR = 32" 32" / 0.2 = 160 OCCUPANTS MAXIMUM OCCUPANCY: MAXIMUM OCCUPANCY: - EDUCATIONAL (GYM): 28 OCCUPANTS
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
5
AutoCAD SHX Text
A-3
AutoCAD SHX Text
LIFE SAFETY
AutoCAD SHX Text
1
AutoCAD SHX Text
2
Page 6: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
%%USTRUCTURAL NOTES
AutoCAD SHX Text
2. ASCE 7-16
AutoCAD SHX Text
I. %%UGENERAL%%U
AutoCAD SHX Text
II. %%UCODE%%U
AutoCAD SHX Text
COMMENCING WORK.
AutoCAD SHX Text
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS RELATED
AutoCAD SHX Text
2. TEMPORARY SHORING AND BRACING FOR CONSTRUCTION IS THE
AutoCAD SHX Text
3. ALL EXCAVATED MATERIAL AND CONSTRUCTION DEBRIS SHALL BE REMOVED
AutoCAD SHX Text
TO CONSTRUCTION BY MAKING FIELD MEASUREMENTS PRIOR TO
AutoCAD SHX Text
1. FLORIDA BUILDING CODE 7TH EDITION (2020).
AutoCAD SHX Text
RESPONSIBILITY OF THE CONTRACTOR.
AutoCAD SHX Text
FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR.
AutoCAD SHX Text
III. %%UDESIGN LOADS
AutoCAD SHX Text
1. ROOF LIVE LOAD----------------- 30 PSF
AutoCAD SHX Text
3. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
AutoCAD SHX Text
2. ROOF DEAD LOAD---------------- 15 PSF
AutoCAD SHX Text
4. ENCLOSURE CLASSIFICATION (NEW STRUCTURE) -- ENCLOSED
AutoCAD SHX Text
IV. %%UDESIGN WIND LOADS%%U
AutoCAD SHX Text
5. WIND EXPOSURE FACTOR ---------------- C
AutoCAD SHX Text
1. ULTIMATE WIND SPEED ------------------ 128 MPH
AutoCAD SHX Text
3. RISK CATEGORY ---------------------- II
AutoCAD SHX Text
2. NOMINAL WIND SPEED ------------------ 101 MPH
AutoCAD SHX Text
3. FLOOR LIVE LOAD---------------- 100 PSF
AutoCAD SHX Text
4. STRUCTURAL STEEL SHAPES, PLATES, ETC. SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
AutoCAD SHX Text
2. WELDED CONNECTIONS SHALL CONFORM TO THE LATEST REVISED CODE OF THE
AutoCAD SHX Text
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST
AutoCAD SHX Text
1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATION FOR DESIGN,
AutoCAD SHX Text
ASTM A500 GRADE B (Fy=46KSI), ALL OTHERS ASTM A36 UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
5. ALL STRUCTURAL CONNECTORS TO BE STAINLESS STEEL, 304 GRADE
AutoCAD SHX Text
WIDE FLG AND WT SHAPES: ASTM A-572 (Fy=50 KSI) OR ASTM A-992 (Fy=50 KSI). TUBE SHAPES:
AutoCAD SHX Text
3. ANCHOR BOLTS SHALL CONFORM TO ASTM A-307.
AutoCAD SHX Text
AMERICAN WELDING SOCIETY, AWS D1.1 USING E-70XX ELECTRODES.
AutoCAD SHX Text
2 MIL DRY THICKNESS.
AutoCAD SHX Text
IX. %%USTEEL (WHERE APPLICABLE)
AutoCAD SHX Text
EDITION.
AutoCAD SHX Text
4. FLOOR DEAD LOAD--------------- 40 PSF
AutoCAD SHX Text
5. WIND LOAD-------------------- SEE TABLE THIS SHEET
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
+16.3
AutoCAD SHX Text
+17.5
AutoCAD SHX Text
P1 (PSF)
AutoCAD SHX Text
10 S.F.
AutoCAD SHX Text
20 S.F.
AutoCAD SHX Text
10 S.F.
AutoCAD SHX Text
20 S.F.
AutoCAD SHX Text
10 S.F.
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
A eff.
AutoCAD SHX Text
ZONE
AutoCAD SHX Text
COMPONENT AND CLADDING WIND PRESSURES
AutoCAD SHX Text
ROOF ANGLE
AutoCAD SHX Text
-27.7
AutoCAD SHX Text
P2 (PSF)
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
+28.1
AutoCAD SHX Text
+30.2
AutoCAD SHX Text
20 S.F.
AutoCAD SHX Text
10 S.F.
AutoCAD SHX Text
20 S.F.
AutoCAD SHX Text
N/A
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
-30.5
AutoCAD SHX Text
-32.8
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
+26.6
AutoCAD SHX Text
50+ S.F.
AutoCAD SHX Text
-28.9
AutoCAD SHX Text
N/A
AutoCAD SHX Text
20 S.F.
AutoCAD SHX Text
10 S.F.
AutoCAD SHX Text
50+ S.F.
AutoCAD SHX Text
+16.3
AutoCAD SHX Text
+17.5
AutoCAD SHX Text
+16.3
AutoCAD SHX Text
+17.5
AutoCAD SHX Text
-25.8
AutoCAD SHX Text
-48.2
AutoCAD SHX Text
-44.8
AutoCAD SHX Text
-71.3
AutoCAD SHX Text
-66.3
AutoCAD SHX Text
-50.0
AutoCAD SHX Text
-44.7
AutoCAD SHX Text
-47.2
AutoCAD SHX Text
ULTIMATE WIND VELOCITY: V = 128 MPH EXP. CAT. "C" RISK CAT. II FULLY ENCLOSED
AutoCAD SHX Text
ULT
AutoCAD SHX Text
NOMINAL WIND VELOCITY: V = 101 MPH EXP. CAT. "C" RISK CAT. II FULLY ENCLOSED
AutoCAD SHX Text
NOM
AutoCAD SHX Text
ULT
AutoCAD SHX Text
NOM
AutoCAD SHX Text
+25.8
AutoCAD SHX Text
+27.7
AutoCAD SHX Text
+24.4
AutoCAD SHX Text
PRESSURE FORCE
AutoCAD SHX Text
+22.2 / -45.3 PSF (MAX)
AutoCAD SHX Text
MAIN WIND FORCE RESISTING SYSTEM (MWFRS), V=128, EXP=C, RISK CAT. II, FULLY ENCLOSED
AutoCAD SHX Text
AREA
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
MWFRS
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
16'-4"±
AutoCAD SHX Text
L/B
AutoCAD SHX Text
N/A
AutoCAD SHX Text
ROOF ANGLE
AutoCAD SHX Text
L.T. 10°
AutoCAD SHX Text
+42.2 / +39.8 PSF
AutoCAD SHX Text
WALL
AutoCAD SHX Text
1.0
AutoCAD SHX Text
N/A
AutoCAD SHX Text
FULLY ENCLOSED STRUCTURE DIFFERENTIAL PRESSURE (DP) FORCES FOR WIND LOAD FERNANDINA BEACH HIGH SCHOOL BASEBALL DUGOUT - FERNANDINA BEACH, FLORIDA
AutoCAD SHX Text
%%C < 10%%D
AutoCAD SHX Text
%%C < 10%%D
AutoCAD SHX Text
%%C < 10%%D
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
2
AutoCAD SHX Text
a = 5'
AutoCAD SHX Text
a
AutoCAD SHX Text
2a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
a
AutoCAD SHX Text
VIII. %%UFOUNDATIONS
AutoCAD SHX Text
1. PLACE GRANULAR FILL IN 8" LAYERS AND COMPACT TO A MINIMUM
AutoCAD SHX Text
2. DEWATER AS REQUIRED, SUCH THAT THE EXCAVATIONS ARE DRY AT
AutoCAD SHX Text
OF 95% OF THE MAXIMUM MODIFIED PROCTOR DRY DENSITY AS
AutoCAD SHX Text
THE TIME OF CONCRETE PLACEMENT.
AutoCAD SHX Text
DETERMINED BY ASTM D-1557.
AutoCAD SHX Text
4. REMOVE ALL TURF AND ORGANIC MATERIALS FROM UNDER
AutoCAD SHX Text
3. THE ENGINEER SHALL APPROVE THE FILL MATERIAL.
AutoCAD SHX Text
THE PROPOSED FOUNDATION AND FLOOR AREA.
AutoCAD SHX Text
5. SOIL BEARING STRENGTH PER GEOTECHNICAL REPORT BY AGES, INC.
AutoCAD SHX Text
FURNACE SLAG.
AutoCAD SHX Text
1. THE LATEST EDITIONS OF THE FOLLOWING STANDARDS SHALL APPLY:
AutoCAD SHX Text
2. THE REQUIRED CONCRETE STRENGTH BASED ON AN AGE OF 28 DAYS FOR
AutoCAD SHX Text
ELEMENTS IN THE STRUCTURE SHALL NOT BE LESS THAN:
AutoCAD SHX Text
ACI 305 (HOT WEATHER CONCRETING) ACI 347 (FORMWORK)
AutoCAD SHX Text
ACI 306 (WINTER CONCRETING) ACI 315 (DETAILING)
AutoCAD SHX Text
ACI 318 (CODE) ACI 304 (PLACING)
AutoCAD SHX Text
DESIGN PROCEDURES SPECIFIED IN ACI 301.
AutoCAD SHX Text
4. MIX PROPORTION AND DESIGN: PROPORTIONS, MIXES, COMPLYING MIX
AutoCAD SHX Text
A. LIMIT OF FLY ASH (ASTM C808 TYPE C OR F) TO NOT TO EXCEED
AutoCAD SHX Text
B. DESIGN MIXES TO PROVIDE NORMAL WEIGHT CONCRETE WITH THE
AutoCAD SHX Text
1. WATER-CEMENT RATIO --------- 0.55 MAXIMUM
AutoCAD SHX Text
BY WEIGHT. DO NOT USE FLY ASH IN CONJUNCTION WITH BLAST
AutoCAD SHX Text
25% OF PORTLAND CEMENT (ASTM C150 TYPE 1 OR 2) CONTENT
AutoCAD SHX Text
3000 PSI FOR FOOTINGS AND SLABS.
AutoCAD SHX Text
FOLLOWING PROPERTIES:
AutoCAD SHX Text
ACI 211.1 (MIX COMPRESSIVE)
AutoCAD SHX Text
3. ALL READY-MIXED CONCRETE SHALL COMPLY WITH ASTM C94-86A.
AutoCAD SHX Text
VI. %%UCONCRETE%%U
AutoCAD SHX Text
C. SLUMP LIMITS: PROPORTION AND DESIGN MIXES TO RESULT IN
AutoCAD SHX Text
1. RAMPS AND SLOPING SURFACES: NOT MORE THAN 3 INCHES.
AutoCAD SHX Text
CONCRETE SLUMP AT A POINT OF PLACEMENT AS FOLLOWS:
AutoCAD SHX Text
D. FINE AND COARSE SHALL BE PER ASTM C33.
AutoCAD SHX Text
2. OTHER CONCRETE: 4" %%P 1".
AutoCAD SHX Text
MECHANICAL VIBRATING EQUIPMENT.
AutoCAD SHX Text
USED TO ADJUST THE MIX AT THE JOB SITE.
AutoCAD SHX Text
THE TRUCK ARRIVES ON THE JOB PROVIDED THAT THE WATER CEMENT
AutoCAD SHX Text
THAN ONE GALLON OF WATER PER CUBIC YARD OF CONCRETE MAY BE
AutoCAD SHX Text
RATIO AND THE SLUMP LIMITS ARE NOT EXCEEDED, HOWEVER NOT MORE
AutoCAD SHX Text
5. SITE ADDED WATER IS PERMITTED WITHIN THE FIRST 15 MINUTES AFTER
AutoCAD SHX Text
6. CONSOLIDATE ALL CONCRETE, OTHER THAN SLABS ON GRADE USING
AutoCAD SHX Text
2. AIR INTRAINMENT (ASTM C 260): 3% %%P 1%.
AutoCAD SHX Text
OF STAINLESS STEEL OR SHALL BE PLASTIC COATED.
AutoCAD SHX Text
HELD RIGIDLY AND ACCURATELY IN PLACE, AND PROTECTED AGAINST
AutoCAD SHX Text
DISPLACEMENT BEFORE AND DURING PLACEMENT OF CONCRETE.
AutoCAD SHX Text
WILL BE EXPOSED IN THE FINISHED STRUCTURE SHALL BE FABRICATED
AutoCAD SHX Text
9. ALL REINFORCING STEEL SHALL BE SUPPORTED ON STANDARD ACCESSORIES,
AutoCAD SHX Text
10. REINFORCEMENT CHAIR LEGS THAT REST ON CONCRETE SURFACES THAT
AutoCAD SHX Text
TICKETS, ONE FOR THE CONTRACTOR, ONE FOR THE OWNER AND ONE
AutoCAD SHX Text
15. DELIVERY TICKETS SHALL PROVIDE THE FOLLOWING INFORMATION:
AutoCAD SHX Text
14. THE READY-MIXED CONCRETE PRODUCER SHALL SUBMIT TRIPLICATE DELIVERY
AutoCAD SHX Text
FOR THE ENGINEER WITH EACH LOAD OF CONCRETE DELIVERED TO THE SITE.
AutoCAD SHX Text
PLACEMENT.
AutoCAD SHX Text
SPREADING.
AutoCAD SHX Text
CONCRETE ARE NOT SEPARATED.
AutoCAD SHX Text
FORMS WILL NOT BE PERMITTED.
AutoCAD SHX Text
THE FOLLOWING SPECIFIC REQUIREMENTS:
AutoCAD SHX Text
MIXTURE FOR 7,14,AND 28 DAY CURE/STRENGTH TESTS.
AutoCAD SHX Text
G. TRUCK NUMBER.
AutoCAD SHX Text
C. CONTRACTOR.
AutoCAD SHX Text
D. JOB LOCATION.
AutoCAD SHX Text
E. TYPE OF CEMENT STANDARD EARLY
AutoCAD SHX Text
J. ADMIXTURES IN CONCRETE, IF ANY.
AutoCAD SHX Text
L. MAXIMUM ALLOWABLE SLUMP.
AutoCAD SHX Text
M. TEMPERATURE OF MIX.
AutoCAD SHX Text
B. NAME OF READY-MIX CONCRETE PLANT.
AutoCAD SHX Text
H. TIME DISPATCHED AND TIME UNLOADED.
AutoCAD SHX Text
I. AMOUNT OF CONCRETE IN LOAD IN CUBIC YARDS.
AutoCAD SHX Text
K. TYPE AND MAXIMUM SIZE OF AGGREGATE.
AutoCAD SHX Text
STRENGTH AND BRAND OF CEMENT.
AutoCAD SHX Text
16. DURING CONCRETE PLACEMENT COMPLY WITH ACI 304R-85 AND
AutoCAD SHX Text
* SHORT TROUGHS OR PIPES USED AS AIDS IN PLACING CONCRETE SHALL BE
AutoCAD SHX Text
ARRANGED AND USED IN SUCH A MANNER THAT THE INGREDIENTS OF THE
AutoCAD SHX Text
* DROPPING THE CONCRETE A DISTANCE OF MORE THAN 4 FEET OR DEPOSITING
AutoCAD SHX Text
A LARGER QUANTITY AT ANY POINT AND RUNNING OR WORKING IT ALONG THE
AutoCAD SHX Text
* PROVIDE THREE TEST CYLINDERS FROM EACH TRUCK LOAD OF CONCRETE
AutoCAD SHX Text
FORMS AND REINFORCEMENT, AND ANY HARDENED DEPOSIT SHALL BE REMOVED
AutoCAD SHX Text
* SPECIAL CARE SHALL BE EXERCISED TO PREVENT SPLASHING CONCRETE ON
AutoCAD SHX Text
F. CEMENT CONTENT IN BAGS PER CUBIC YARD OF CONCRETE.
AutoCAD SHX Text
WELDING.
AutoCAD SHX Text
SPECIFIED ON DRAWINGS.
AutoCAD SHX Text
PLACEMENT OPERATIONS.
AutoCAD SHX Text
OF CEMENT AND PROPER HARDENING.
AutoCAD SHX Text
CONTINUOUSLY MOIST FOR NOT LESS THAN 72 HOURS.
AutoCAD SHX Text
BREAKDOWN.
AutoCAD SHX Text
BEFORE COVERING WITH FRESH CONCRETE.
AutoCAD SHX Text
EXCESSIVE COLD OR HEAT, AND MAINTAIN WITHOUT DRYING AT A RELATIVELY
AutoCAD SHX Text
CONSISTENT TEMPERATURE FOR A PERIOD OF TIME NECESSARY FOR HYDRATION
AutoCAD SHX Text
11. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING
AutoCAD SHX Text
AND EXCESSIVE COLD OR HEAT, AND MAINTAIN WITHOUT DRYING AT A
AutoCAD SHX Text
RELATIVELY CONSISTENT TEMPERATURE FOR A PERIOD OF TIME
AutoCAD SHX Text
NECESSARY FOR HYDRATION OF CEMENT AND PROPER HARDENING.
AutoCAD SHX Text
CONCRETE SURFACE AFTER PLACING AND FINISHING. WEATHER PERMITTING, KEEP
AutoCAD SHX Text
13. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND
AutoCAD SHX Text
12. START INITIAL CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM
AutoCAD SHX Text
* CONCRETE SHALL BE PLACED IN LAYERS NOT OVER 18" DEEP AND EACH
AutoCAD SHX Text
LAYER SHALL BE VIBRATED INTO PLACE IN SUCH A MANNER AS WILL NOT CAUSE
AutoCAD SHX Text
THE INGREDIENTS TO SEPARATE. WHERE NECESSARY, VIBRATION SHALL BE
AutoCAD SHX Text
SUPPLEMENTED BY HAND SPADING TO SECURE THESE RESULTS. VIBRATIONS
AutoCAD SHX Text
SHALL BE KEPT CONSTANTLY IN MOTION AND SHALL NOT BE HELD IN ONE
AutoCAD SHX Text
LOCATION LONG ENOUGH TO DRAW A POOL OF GROUT OR WATER FROM THE
AutoCAD SHX Text
CONCRETE. MAINTAIN ADDITIONAL MANPOWER AND SPARE EQUIPMENT TO AVOID
AutoCAD SHX Text
* MAINTAIN REINFORCING IN THE PROPER POSITION DURING CONCRETE
AutoCAD SHX Text
A. DATE.
AutoCAD SHX Text
14. PROVIDE STANDARD REINFORCEMENT SPLICES BY LAPPING ENDS, PLACING
AutoCAD SHX Text
BARS IN CONTACT, AND TYING WIRE TIGHTLY. COMPLY WITH REQUIREMENTS IN
AutoCAD SHX Text
ACI 318-86 FOR MINIMUM LAP OF SPLICED BARS AND AS INDICATED ON
AutoCAD SHX Text
DRAWINGS. REINFORCING BAR ASSEMBLIES SHALL NOT BE MADE BY TACK
AutoCAD SHX Text
15. STEEL REINFORCEMENT, AT THE TIME CONCRETE IS PLACED AROUND IT, SHALL
AutoCAD SHX Text
AND ALL OTHER COATINGS, WHICH WOULD REDUCE OR DESTROY BOND BETWEEN
AutoCAD SHX Text
STEEL AND CONCRETE. CLEAN REINFORCEMENT AS NECESSARY PRIOR TO
AutoCAD SHX Text
BE FREE FROM LOOSE RUST AND MILL SCALE, OIL, GREASE, PAINT, EARTH, ICE,
AutoCAD SHX Text
PLACEMENT TO ACHIEVE THIS RESULT.
AutoCAD SHX Text
EXPOSED INSIDE CORNERS MAY BE FORMED EITHER SQUARE OR CHAMFERED.
AutoCAD SHX Text
2. THE DESIGN AND ENGINEERING OF THE FORMWORK AS WELL AS ITS
AutoCAD SHX Text
CONFORM TO "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK", ACI 347-84.
AutoCAD SHX Text
3. FORMS SHALL CONFORM TO SHAPE, LINES, AND DIMENSIONS SHOWN ON THE
AutoCAD SHX Text
DRAWINGS. THEY SHALL BE SUBSTANTIAL AND DESIGNED TO SAFELY RESIST THE
AutoCAD SHX Text
PRESSURE AND WEIGHT OF THE CONCRETE, AND SHALL BE PROPERLY TIED AND
AutoCAD SHX Text
BRACED OR SHORED SO AS TO MAINTAIN POSITION AND SHAPE.
AutoCAD SHX Text
4. DESIGN FORMWORK TO BE READILY REMOVABLE WITHOUT IMPACT, SHOCK, OR
AutoCAD SHX Text
DAMAGE TO CAST-IN-PLACE CONCRETE SURFACES AND ADJACENT MATERIALS.
AutoCAD SHX Text
5. PROPERLY BRACE AND TIE THE FORMS TOGETHER SO AS TO MAINTAIN
AutoCAD SHX Text
POSITION AND SHAPE AND TO ENSURE SAFETY TO PERSONNEL DURING CONCRETE
AutoCAD SHX Text
6. CONSTRUCT ALL BRACING, SUPPORTING MEMBERS, AND CENTERING OF AMPLE
AutoCAD SHX Text
SIZE AND STRENGTH TO SAFELY CARRY, WITHOUT EXCESSIVE DEFLECTION, ALL
AutoCAD SHX Text
DEAD AND LIVE LOADS TO WHICH THEY MAY BE SUBJECTED.
AutoCAD SHX Text
7. PROPERLY SPACE THE FORMS APART AND SECURELY TIE THEM TOGETHER,
AutoCAD SHX Text
CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL
AutoCAD SHX Text
8. REINFORCING BARS SHALL COMPLY WITH ASTM A615-86, GRADE 60,
AutoCAD SHX Text
9. FABRICATE REINFORCING BARS TO CONFORM TO REQUIRED SHAPES AND
AutoCAD SHX Text
DIMENSIONS, COMPLYING WITH CRSI "DETAILING MANUAL-1980". IN CASE OF
AutoCAD SHX Text
FABRICATING ERRORS, DO NOT REBEND OR STRAIGHTEN REINFORCEMENT IN A
AutoCAD SHX Text
MANNER THAT WILL INJURE OR WEAKEN THE MATERIAL. FABRICATION
AutoCAD SHX Text
10. ALL REINFORCING BARS SHALL BE PLACED IN ACCORDANCE WITH CRSI
AutoCAD SHX Text
"RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS", AND AS
AutoCAD SHX Text
11. BARS SHALL BE PLACED TO THE TOLERANCE SPECIFIED IN ACI 117-81.
AutoCAD SHX Text
12. PLACE ALL REINFORCEMENT ACCORDING TO THE APPROVED PLACEMENT
AutoCAD SHX Text
DRAWINGS. USE SUFFICIENT BAR SUPPORTS, TIE, ANCHORS, SIDE FORM SPACERS,
AutoCAD SHX Text
ADDITIONAL REINFORCING BARS IF REQUIRED, AND OTHER ACCESSORIES TO HOLD
AutoCAD SHX Text
13. PLACE REINFORCEMENT TO OBTAIN NOT LESS THAN THE MINIMUM COVERAGES
AutoCAD SHX Text
FOR CONCRETE PROTECTION. ARRANGE, SPACE, AND SECURELY TIE BARS AND BAR
AutoCAD SHX Text
SUPPORTS TOGETHER WITH 16 GAUGE WIRE TO HOLD REINFORCEMENT ACCURATELY IN
AutoCAD SHX Text
POSITION DURING CONCRETE PLACEMENT OPERATION. SET WIRE TIES SO THAT
AutoCAD SHX Text
TWISTED ENDS ARE DIRECTED AWAY FROM EXPOSED CONCRETE SURFACES.
AutoCAD SHX Text
USING METAL SPREADER TIES THAT GIVE POSITIVE TYING AND ACCURATE
AutoCAD SHX Text
ALL BARS SECURELY IN PLACE.
AutoCAD SHX Text
INCLUDING SUPPLEMENTARY REQUIREMENT S1.
AutoCAD SHX Text
TOLERANCES SHALL COMPLY WITH ACI 117-81.
AutoCAD SHX Text
1. CHAMFER ALL EXPOSED CONCRETE OUTSIDE CORNERS. FORM CHAMFERS WITH
AutoCAD SHX Text
3/4" X 3/4" STRIPS, ACCURATELY FORMED AND SURFACED TO PRODUCE
AutoCAD SHX Text
UNIFORMLY STRAIGHT LINES AND TIGHT EDGE JOINTS. EXTEND TERMINAL EDGES
AutoCAD SHX Text
TO REQUIRED LIMIT AND MITER CHAMFER STRIPS AT CHANGES IN DIRECTION.
AutoCAD SHX Text
VII. %%UCONCRETE FORMWORK AND REINFORCING
AutoCAD SHX Text
16. COORDINATE PLACEMENT OF REINFORCING WITH DUCTWORK AND OR PLUMBING
AutoCAD SHX Text
LOCATIONS. SEE PLUMBING AND MECHANICAL DRAWINGS.
AutoCAD SHX Text
HAVE A UNIFORM PITCH TO DRAINS OF WITH PITCH (SLOPE)
AutoCAD SHX Text
AS SHOWN ON DWGS.
AutoCAD SHX Text
IN A 10 FOOT RADIUS, NON-ACCUMULATIVE.
AutoCAD SHX Text
MEMBRANE AND SHALL HAVE A TOLERANCE OF 1/4" PLUS OR MINUS
AutoCAD SHX Text
TROWELED IMMEDIATELY AFTER FLOATING WITH A POWER-DRIVEN TROWEL=
AutoCAD SHX Text
CONSOLIDATE SURFACES BY AN INITIAL AND A FINAL HAND TROWELING
AutoCAD SHX Text
OPERATION. FINAL TROWELING SHALL BE DONE WHEN A RINGING SOUND IS
AutoCAD SHX Text
PRODUCED AS THE TROWEL IS PASSED OVER THE SURFACE. THE FINISHED
AutoCAD SHX Text
SURFACE SHALL BE FREE OF TROWEL MARKS AND UNIFORM IN TEXTURE AND
AutoCAD SHX Text
APPEARANCE. FINAL SURFACE FINISH TO BE APPROVED BY THE ARCHITECT.
AutoCAD SHX Text
19. WHERE FLOOR DRAINS ARE INSTALLED IN FLOOR SLABS, THE FLOOR
AutoCAD SHX Text
SHALL BE HELD LEVEL AROUND WALLS AND THE FLOORS SHALL
AutoCAD SHX Text
18. HARD STEEL TROWEL FINISH THE CONCRETE SURFACE. SLABS SHALL BE
AutoCAD SHX Text
TO OCCUR PRIOR TO CONCRETE HARDENING.
AutoCAD SHX Text
SHALL BE EITHER SIMPSON "AT" OR HILTI HY 150.
AutoCAD SHX Text
8. EPOXY ADHESIVE FOR FASTENING BOLTS, REBAR, OR DOWELS IN CONCRETE
AutoCAD SHX Text
7. DO NOT PLACE CONCRETE DURING RAIN OR IF ANY RAIN IS LIKELY
AutoCAD SHX Text
17. COORDINATE OPENINGS IN SLAB ABOVE GRADE FOR DUCTWORK AND PENETRATIONS.
AutoCAD SHX Text
17. THE CONCRETE SHALL RECEIVE TOPPINGS OF WATERPROOF
AutoCAD SHX Text
- C&C WIND PRESSURE FORCES LISTED ARE BASED ON NOMINAL WIND SPEEDS. REDUCTION ALLOWED PER PER SECTION 1609.3, FLORIDA BUILDING CODE 2020 (6TH EDITION). P = (0.6)(P ) - MWFRS PRESSURE FORCES DERIVED FROM ASCE 7-16 CHAPTER 27 (27.5), PART 2, SIMPLIFIED METHOD (BUILDING CLASS 1) AND VALUES SHOWN ARE BASED ON ULTIMATE CLASS 1) AND VALUES SHOWN ARE BASED ON ULTIMATE WIND SPEED (LFRD) - C&C PRESSURE FORCES DERIVED FROM CHAPTER 30 (30.7), PART 4, LOW RISE (SIMPLIFIED) - ZONE 5 IS DEFINED AS 5-FT FROM EACH EXTERIOR WALL CORNER - ZONE 4 IS DEFINED AS ALL OTHER EXTERIOR WALL AREA - IMPACT RESISTANT GLAZING IS NOT REQUIRED PER ASCE 7-16 AND F.B.C. 2020
AutoCAD SHX Text
LIGHT GAUGE FRAMING TO BE USED IN LIEU OF WOOD STUDS. ALL WORK SHALL CONFORM TO THE LATEST ADDITION OF THE AISI SPECIFICATION FOR THE DESIGN OF COLD ROLLED STEEL MEMBERS.
AutoCAD SHX Text
PRIOR TO FABRICATION OF FRAMING, THE CONTRACTOR SHALL FIELD VERIFY ALL WALL LAYOUT AND REQUIRED INFORMATION.
AutoCAD SHX Text
BRIDGING INSTALLATION: INSTALL SOLID BRIDGING AS REQUIRED.
AutoCAD SHX Text
STUDS SHALL BE PRODUCT OF DIETRICH INDUSTRIES OR EQUAL.
AutoCAD SHX Text
METAL WALL STUD SHEETS SHALL COMPLY WITH ASTM A1003 / A1003M
AutoCAD SHX Text
INTERIOR, NON-STRUCTURAL, METAL WALL STUDS SHALL CONFORM TO ASTM C645-08a, "STANDARD SPECIFICATIONS FOR NONSTRUCTURAL STEEL FRAMING MEMBERS."
AutoCAD SHX Text
INTERIOR, NON-STRUCTURAL, METAL WALL STUDS SHALL CONFORM TO ASTM C754-08, "STANDARD SPECIFICATION FOR INSTALLATION OF STEEL FRAMING MEMBERS".
AutoCAD SHX Text
MASONRY FURRING, IF REQUIRED, TO RECEIVE SINGLE LEG (Z-FURRING) OR DOUBLE LEG (HALF CHANNEL) GALV. STEEL STUD, 18 MIL THICK (25ga). INTERIOR WALL STUDS TO RECEIVE DOUBLE LEG CHANNELS 30 MIL. (20 ga.) GALV. STEEL STUDS.
AutoCAD SHX Text
1.
AutoCAD SHX Text
2.
AutoCAD SHX Text
3.
AutoCAD SHX Text
5.
AutoCAD SHX Text
6.
AutoCAD SHX Text
7.
AutoCAD SHX Text
8.
AutoCAD SHX Text
4.
AutoCAD SHX Text
V. %%ULIGHT GAUGE FRAMING
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
6
AutoCAD SHX Text
S-0
AutoCAD SHX Text
STRUCT. NOTES
AutoCAD SHX Text
1
Page 7: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
MATCH EXIST. SLAB ELEV.
AutoCAD SHX Text
4" THICK, 3,000 PSI SLAB W/ 6 x 6 x W1.4 WWM OVER 6 MIL V.B. OVER x 6 x W1.4 WWM OVER 6 MIL V.B. OVER x 6 x W1.4 WWM OVER 6 MIL V.B. OVER 6 x W1.4 WWM OVER 6 MIL V.B. OVER 6 x W1.4 WWM OVER 6 MIL V.B. OVER x W1.4 WWM OVER 6 MIL V.B. OVER x W1.4 WWM OVER 6 MIL V.B. OVER W1.4 WWM OVER 6 MIL V.B. OVER W1.4 WWM OVER 6 MIL V.B. OVER CLEAN, COMPACTED, TREATED SOIL
AutoCAD SHX Text
24" X 24" UNDER COL.
AutoCAD SHX Text
24" X 24" UNDER COL.
AutoCAD SHX Text
24" X 24" UNDER COL.
AutoCAD SHX Text
24" X 16" TURNDOWN, SEE DETAIL THIS SHEET
AutoCAD SHX Text
24" X 24" UNDER COL.
AutoCAD SHX Text
EXISTING BUILDING
AutoCAD SHX Text
FOUNDATION PLAN SCALE: " = 1'-0"14" = 1'-0"
AutoCAD SHX Text
N
AutoCAD SHX Text
8" CMU W/ #5 VERT. AT EA. SIDE OF CORNERS AND OPENINGS AND N.T.E. 32" O.C.
AutoCAD SHX Text
#5 DOWEL (TYP), SEE DETAIL THIS SHEET
AutoCAD SHX Text
1" DEEP CONTROL JOINT (TYP), SEE DETAIL THIS SHEET
AutoCAD SHX Text
6 x 6 x W1.4 WWM x 6 x W1.4 WWMx 6 x W1.4 WWM 6 x W1.4 WWM6 x W1.4 WWM x W1.4 WWMx W1.4 WWM W1.4 WWMW1.4 WWM
AutoCAD SHX Text
T.O. NEW SLAB (MATCH EXIST.)
AutoCAD SHX Text
NEW 8" CMU WALL
AutoCAD SHX Text
TURNDOWN DETAIL SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text
6 x 6 x W1.4 WWM x 6 x W1.4 WWMx 6 x W1.4 WWM 6 x W1.4 WWM6 x W1.4 WWM x W1.4 WWMx W1.4 WWM W1.4 WWMW1.4 WWM
AutoCAD SHX Text
T.O. NEW SLAB
AutoCAD SHX Text
6 MIL VAPOR BARRIER
AutoCAD SHX Text
TURNDOWN AT EXISTING DUGOUT WALL DETAIL SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text
EXIST. CMU WALL
AutoCAD SHX Text
EXIST. SLAB
AutoCAD SHX Text
#5 DOWEL, 12" LONG, 6" EPOXY EMBED INTO EXISTING SLAB N.T.E. 36 O.C.
AutoCAD SHX Text
INTERIOR FOOTER DETAIL SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
POST, SEE PLANS
AutoCAD SHX Text
T.O. NEW SLAB
AutoCAD SHX Text
(2) #5 CONT.
AutoCAD SHX Text
#5 CONT.
AutoCAD SHX Text
(2) #5 E/W
AutoCAD SHX Text
TERMINATE HORIZONTAL JOINT REINF. EA. SIDE OF CONTROL JOINT
AutoCAD SHX Text
PRE-MOLDED HARD RUBBER OR PVC CONTROL JOINT N.T.E. 20-FT SPACING
AutoCAD SHX Text
#5 VERTICAL IN GROUT FILLED CELL SIDE OF CONTROL JOINT (TYP)
AutoCAD SHX Text
NEW CMU WALL
AutoCAD SHX Text
MASONRY CONTROL JOINT SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
6 x 6 x W1.4 WWM x 6 x W1.4 WWMx 6 x W1.4 WWM 6 x W1.4 WWM6 x W1.4 WWM x W1.4 WWMx W1.4 WWM W1.4 WWMW1.4 WWM
AutoCAD SHX Text
6 MIL VAPOR BARRIER
AutoCAD SHX Text
CLEAN, COMP. SOIL
AutoCAD SHX Text
CLEAN, COMP. SOIL
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
#5 J-HOOK N.T.E. 32" O.C.
AutoCAD SHX Text
#5 CONT. VERT. N.T.E. 32" O.C.
AutoCAD SHX Text
18"x1" SAWCUT, 8'-10' SPACING
AutoCAD SHX Text
CONCRETE CONTROL JOINT SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text
6 x 6 x W1.4 WWM x 6 x W1.4 WWMx 6 x W1.4 WWM 6 x W1.4 WWM6 x W1.4 WWM x W1.4 WWMx W1.4 WWM W1.4 WWMW1.4 WWM
AutoCAD SHX Text
6 MIL VAPOR BARRIER
AutoCAD SHX Text
CLEAN, COMP. SOIL
AutoCAD SHX Text
12" THK. STEEL BASE PLATE W/ " EPOXY ANCHORS, 12" EPOXY ANCHORS,MIN. 4" EMBED (4 PL)
AutoCAD SHX Text
STRUCTURAL SLAB, SEE PLANS
AutoCAD SHX Text
#5 J-HOOK INTO GR. BM.
AutoCAD SHX Text
MIN. 36" SPLICE LG.
AutoCAD SHX Text
#5 VERTICAL N.T.E. 32" O.C.
AutoCAD SHX Text
NEW ADDITION INTERIOR
AutoCAD SHX Text
1-1/2" FIRRING
AutoCAD SHX Text
(TYP EXT. CMU WALLS)
AutoCAD SHX Text
CONT. BOND BEAM
AutoCAD SHX Text
T.O. MASONRY
AutoCAD SHX Text
%%UEXTERIOR WALL SECTION
AutoCAD SHX Text
(SCALE: 1/4"=1'-0")
AutoCAD SHX Text
T.O. SLAB
AutoCAD SHX Text
MATCH EXISTING DUGOUT GRADE ASSUME EL. 20.0
AutoCAD SHX Text
8" CMU WALL, FILL CELLS THAT CONTAIN REBAR ONLY
AutoCAD SHX Text
6" MIN
AutoCAD SHX Text
24"
AutoCAD SHX Text
ASSUMED FFE 20 (CONTRACTOR TO VERIFY)
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
MATCH EXISTING MASONRY ASSUME EL. 28.0
AutoCAD SHX Text
(2) 2x8 TOP PLATE
AutoCAD SHX Text
2-#5 CONT.
AutoCAD SHX Text
CLIP, SEE PLANS
AutoCAD SHX Text
EDGE, 12" O.C. FIELD
AutoCAD SHX Text
SCREWS N.T.E. 6" O.C.
AutoCAD SHX Text
SHEATHING W/#8X1"(LG)
AutoCAD SHX Text
MIN. 1/2" FIRE-RATED
AutoCAD SHX Text
JOIST, SEE PLANS
AutoCAD SHX Text
(SEE SHEET A0)
AutoCAD SHX Text
DOUBLE UNDERLAYMENT
AutoCAD SHX Text
METAL ROOF OVER
AutoCAD SHX Text
FIN. GR.
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
7
AutoCAD SHX Text
S-1
AutoCAD SHX Text
FOUNDATION PLAN
AutoCAD SHX Text
1
Page 8: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
0.5/12
AutoCAD SHX Text
EXISTING DUGOUT
AutoCAD SHX Text
NEW ADDITION
AutoCAD SHX Text
ROOF FRAMING PLAN SCALE: " = 1'-0"14" = 1'-0"
AutoCAD SHX Text
2x10 METAL STUD JOISTS N.T.E. 16" O.C.
AutoCAD SHX Text
JOIST ATTACHED WITH (2) SIMPSON H2.5 (TYP)
AutoCAD SHX Text
JOIST ATTACHED WITH SIMPSON LUS28 (UNLESS NOTED OTHERWISE)
AutoCAD SHX Text
DBL END JOIST ATTACHED WITH SIMPSON HUC210 (TYP EA. SIDE)
AutoCAD SHX Text
DBL END JOIST ATTACHED WITH SIMPSON HUC210 (TYP)
AutoCAD SHX Text
JOIST ATTACHED WITH (2) SIMPSON H2.5 (TYP)
AutoCAD SHX Text
JOIST ATTACHED WITH SIMPSON LUS28 (TYP)
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
TACK WELD JOIST TO HEADER (TYP)
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
N
AutoCAD SHX Text
HSS4X2X1/4
AutoCAD SHX Text
2x10 METAL STUD JOISTS N.T.E. 16" O.C.
AutoCAD SHX Text
2x10 METAL STUD JOISTS N.T.E. 16" O.C.
AutoCAD SHX Text
HSS4X2X1/4
AutoCAD SHX Text
HSS4X2X1/4
AutoCAD SHX Text
HSS4X2X1/4
AutoCAD SHX Text
HSS4X2X1/4
AutoCAD SHX Text
HSS4X4X 316
AutoCAD SHX Text
8F8-1B
AutoCAD SHX Text
8F8-1B
AutoCAD SHX Text
8F8-1B
AutoCAD SHX Text
MASONRY LINTEL (TYP)
AutoCAD SHX Text
HSS4X4X 316
AutoCAD SHX Text
HSS4X4X 316
AutoCAD SHX Text
HSS4X4X 316
AutoCAD SHX Text
LINTEL BEAM NOTES: 1. LINTELS NOTED ON PLANS ARE U-TYPE, PRECAST, AS SPECIFIED BY CAST-CRETE. ALTERNATES ARE NOT ACCEPTABLE. 2. SEE DIAGRAM THIS SHEET FOR LINTEL BEAM NOMENCLATURE. 3. IF LINTEL BEAMS RESIDE AT THE TIE-BEAM ELEVATION, INCORPORATE THE REINFORCEMENT INTO THE TIE-BEAM. 4. WHERE LINTEL BEAMS RESIDE BELOW THE TIE-BEAM, INSTALL LINTEL BEAM AS NOTED UNDER TIE-BEAM. 5. ALL COMPOSITE LINTEL BEAM REINFORCEMENT TO BE GRADE 60.
AutoCAD SHX Text
8F16-1B/2T
AutoCAD SHX Text
QUANTITY OF #5 REBAR AT TOP OF U-LINTEL (WHERE APPLICABLE)
AutoCAD SHX Text
NOMINAL WIDTH
AutoCAD SHX Text
NOMINAL HEIGHT
AutoCAD SHX Text
%%UCOMPOSITE LINTEL BEAM DESIGNATION
AutoCAD SHX Text
QUANTITY OF #5 REBAR AT BOTTOM OF U-LINTEL
AutoCAD SHX Text
FILLED W/GROUT (U-UNFILLED)
AutoCAD SHX Text
BOTTOM MEMBER OF COMPOSITE LINTEL BEAM TO BE CAST-CRETE 8" U-LINTELS BASED ON STANDARD LENGTHS 1-#7 MAY BE SUBSTITUTED FOR 2-#5 FOR TOP
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
8
AutoCAD SHX Text
S-2
AutoCAD SHX Text
FRAMING PLAN
AutoCAD SHX Text
1
Page 9: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
EXISTING DUGOUT 26' EASTWARD
AutoCAD SHX Text
SECTION A-A SCALE: " = 1'-0"38" = 1'-0"
AutoCAD SHX Text
SECTION B-B SCALE: " = 1'-0"38" = 1'-0"
AutoCAD SHX Text
SECTION C-C SCALE: " = 1'-0"38" = 1'-0"
AutoCAD SHX Text
NEW (2) 2x10 METAL STUD END JOIST (TYP)
AutoCAD SHX Text
NEW JOIST, SEE PLANS (TYP)
AutoCAD SHX Text
NEW (2) 2x8 METAL STUD TOP PLATE (TYP)
AutoCAD SHX Text
EXIST. CMU WALL
AutoCAD SHX Text
EXIST. METAL POST (TYP)
AutoCAD SHX Text
NEW (2) 2x10 METAL STUD BEAM
AutoCAD SHX Text
EXIST. CMU WALL
AutoCAD SHX Text
NEW 2x4 METAL STUD ROOF SUPPORT WALL
AutoCAD SHX Text
NEW (2) 2x8 METAL STUD TOP PLATE (TYP)
AutoCAD SHX Text
NEW (2) 2x10 METAL STUD END JOIST (TYP)
AutoCAD SHX Text
NEW JOIST, SEE PLANS (TYP)
AutoCAD SHX Text
NEW CMU WALL
AutoCAD SHX Text
0.5/12
AutoCAD SHX Text
NEW METAL ROOF. SEE FLORIDA PRODUCT APPROVAL SUBMITTAL AND SHEET A-0.
AutoCAD SHX Text
NEW (2) 2x10 METAL STUD END JOIST
AutoCAD SHX Text
EXIST. CMU WALL
AutoCAD SHX Text
NEW CMU WALL
AutoCAD SHX Text
NEW (2) 2x8 METAL STUD TOP PLATE
AutoCAD SHX Text
NEW (2) 2x10 METAL STUD BEAM
AutoCAD SHX Text
NEW 2x4 METAL STUD ROOF SUPPORT WALL W/ STUDS N.T.E. 16" O.C.
AutoCAD SHX Text
NEW (3) 2x10 METAL STUD GIRDER
AutoCAD SHX Text
NEW (3) 2x4 METAL STUD SUPPORT
AutoCAD SHX Text
NEW (2) 2x10 METAL STUD GIRDER
AutoCAD SHX Text
NEW 2x4 METAL STUD WALL W/ STUDS N.T.E. 16" O.C. (TYP)
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
NEW 2x4 METAL STUD ROOF SUPPORT WALL W/ STUDS N.T.E. 16" O.C.
AutoCAD SHX Text
NEW METAL ROOF. SEE FLORIDA PRODUCT APPROVAL SUBMITTAL AND SHEET A-0.
AutoCAD SHX Text
NEW METAL ROOF. SEE FLORIDA PRODUCT APPROVAL SUBMITTAL AND SHEET A-0.
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
9
AutoCAD SHX Text
S-3
AutoCAD SHX Text
FRAMING DETAILS
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
Page 10: S S-1 - FOUNDATION PLAN S-2 - FRAMING PLAN S-3 - FRAMING ...
AutoCAD SHX Text
ELECTRICAL PLAN SCALE: " = 1'-0"14" = 1'-0"
AutoCAD SHX Text
EXISTING STORAGE
AutoCAD SHX Text
EXISTING HOME DUGOUT
AutoCAD SHX Text
EXISTING DOUBLE DOORS
AutoCAD SHX Text
A/C
AutoCAD SHX Text
EXISTING ELECTRIC
AutoCAD SHX Text
3068
AutoCAD SHX Text
WEIGHT ROOM 613 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
A/C
AutoCAD SHX Text
N
AutoCAD SHX Text
3068
AutoCAD SHX Text
2868
AutoCAD SHX Text
(2) 3068
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
PREWIRE & BRACE FOR FAN
AutoCAD SHX Text
110 OUTLET
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
ELECTRICAL PANEL
AutoCAD SHX Text
$
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
S
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
LIGHT FIXTURE CEILING MOUNTED
AutoCAD SHX Text
LIGHT FIXTURE WALL MOUNTED
AutoCAD SHX Text
$
AutoCAD SHX Text
$
AutoCAD SHX Text
OUTDOOR RATED FIXTURE (2 PL)
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
CABINETS (10)
AutoCAD SHX Text
WARM-UP AND GATHERING ROOM 714 SF
AutoCAD SHX Text
EXIT SIGN WITH EMERGENCY LIGHT PACK (TYP)
AutoCAD SHX Text
6.
AutoCAD SHX Text
5.
AutoCAD SHX Text
4.
AutoCAD SHX Text
3.
AutoCAD SHX Text
2.
AutoCAD SHX Text
%%UGENERAL ELECTRICAL NOTES
AutoCAD SHX Text
1.
AutoCAD SHX Text
7.
AutoCAD SHX Text
8.
AutoCAD SHX Text
11.
AutoCAD SHX Text
9.
AutoCAD SHX Text
10.
AutoCAD SHX Text
12.
AutoCAD SHX Text
13.
AutoCAD SHX Text
THE CONTRACTOR SHALL KEEP PRINTS OF DRAWINGS MARKED TO CLEARLY INDICATE ALL CHANGES MADE AND THE EXACT LOCATIONS OF CONDUITS CONCEALED UNDER CONCRETE OR PAVING. A COPY OF THESE DRAWINGS SHALL BE SENT TO THE OWNER UPON COMPLETION OF THE JOB.
AutoCAD SHX Text
THE MINIMUM SPACING BETWEEN AND THE CLEARANCE AROUND ELECTRICAL PANEL, MCC'S, CONTROLLERS, SAFETY SWITCHES AND CONTACTORS SHALL BE AS REQUIRED BY THE NATIONAL ELECTRICAL CODE 2017, AS NOTED ON THE DRAWINGS OR AS REQUIRED BY LOCAL ORDINANCES.
AutoCAD SHX Text
CONDUCTORS SHALL BE AS FOLLOWS: A. ALL CONDUCTORS SHALL BE COPPER STRANDED. ALL CONDUCTORS SHALL BE COPPER STRANDED. B. ALL CONDUCTORS SHALL BE TYPE "THWN" OR "THHN" UNLESS SHOWN OTHERWISE. ALL CONDUCTORS SHALL BE TYPE "THWN" OR "THHN" UNLESS SHOWN OTHERWISE.
AutoCAD SHX Text
ALL EQUIPMENT EXPOSED TO THE WEATHER OR WET CONDITIONS SHALL BE NEMA 4X OR NEMA 3R WHERE INDICATED.
AutoCAD SHX Text
PROVIDE A NEATLY TYPED COPY OF THE APPLICABLE PANEL SCHEDULE INSIDE EACH PANEL DOOR AND PLACE INSIDE A PLASTIC COVER. USE PANEL SCHEDULE SHEETS AS A GUIDE.
AutoCAD SHX Text
ALL ELECTRICAL WORK SHALL CONFORM TO LOCAL STATE AND NATIONAL ELECTRICAL CODES.
AutoCAD SHX Text
ALL CONDUITS, APPROVED FOR DIRECT BURIAL, SHALL BE BURIED A MINIMUM OF 36" AND SHALL BE A MINIMUM OF 1" IN DIAMETER, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
SPLICES: CONDUCTORS SHALL NOT BE SPLICED EXCEPT IN OUTLETS OR JUNCTION BOXES, CONDUCTORS SHALL NOT BE SPLICED EXCEPT IN OUTLETS OR JUNCTION BOXES, TROUGHS, AND GUTTERS. JUNCTION BOXES MAY BE UTILIZED WHERE REQUIRED. CONDUCTORS #10 AWG AND SMALLER SHALL BE SPLICED BY TWISTING AND INSTALLATION OF 3M "SCOTCH-LOKS" OR T&B "PIGGY" CONNECTORS. CONDUCTORS #8 AWG AND LARGER SHALL BE SPLICED WITH APPROVED MECHANICAL CONNECTORS, PLUS GUM TAPE, UNDERWRITER'S LABORATORIES LISTED, FOR USE AS SOLE INSULATION. THE GUM TAPE SHALL BE APPLIED SO AS TO COVER ALL EDGES AND FORM A SMOOTH SURFACE FOR PLASTIC TAPE. THE FINISHED CONNECTION SHALL HAVE AN INSULATION VALUE EQUAL TO THAT OF THE CONDUCTOR INSULATION.
AutoCAD SHX Text
JUNCTION BOX TO BE SUPPORTED FROM JOIST USING BRACKETS LISTED TO MAINTAIN BOX STABILITY WITH CABLE SUSPENDED FROM IT.
AutoCAD SHX Text
ALL CONDUITS THAT ARE ROUTED VERTICALLY IN WALLS THAT HAVE FIRE BLOCKING AT THE TOP SHALL HAVE A SEALING SYSTEM INSTALLED AROUND THE CONDUITS WHICH PENETRATE THE FIRE BLOCKING THAT RESTORES THE INTEGRITY OF THE FIRE BLOCKING.
AutoCAD SHX Text
PROVIDE BONDING FOR ALL METAL RACEWAYS THAT CONTAINS GROUNDING ELECTRODE AS PER NEC 2017.
AutoCAD SHX Text
CONTRACTOR SHALL VISIT AND SURVEY THE SITE THOROUGHLY TO INSPECT CONDITIONS INCLUDING BUT NOT LIMITED TO ACCESS AND WORK SPACE LIMITATIONS.
AutoCAD SHX Text
ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH NEC 2014.
AutoCAD SHX Text
14.
AutoCAD SHX Text
FINAL LIGHTING LAYOUT TO BE COORDINATED BY CONTRACTOR WITH OWNER.
AutoCAD SHX Text
North / Elev Key
AutoCAD SHX Text
Sheet
AutoCAD SHX Text
Page
AutoCAD SHX Text
of
AutoCAD SHX Text
FBHS - HICKORY STREET
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CIVIL, ENVIRONMENTAL, MECHANICAL, & STRUCTURAL ENGINEERING
AutoCAD SHX Text
20 S. 4th STREET * FERNANDINA BEACH, FL 32034
AutoCAD SHX Text
GILLETTE & ASSOCIATES, INC.
AutoCAD SHX Text
PHONE: 904-261-8819 * www.gilletteassociates.com
AutoCAD SHX Text
CERTIFICATE OF AUTHORIZATION NO. 9332
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
NOTE: SOME DETAILS IN THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL AND MAY NOT BE CALLED OUT ON PLANS. CONTRACTOR SHALL BECOME FAMILIAR WITH AND FOLLOW ALL DETAILS DURING CONSTRUCTION IN ALL TYPICAL AREAS.
AutoCAD SHX Text
ASA R. GILLETTE, P.E. * FL. PE NO. 56177
AutoCAD SHX Text
FLORIDA P.E. NO. 56177
AutoCAD SHX Text
ASA R. GILLETTE, P.E.
AutoCAD SHX Text
%%UREGISTERED DESIGN PROFESSIONAL
AutoCAD SHX Text
ISSUE FOR SCHOOL BOARD APPROVAL
AutoCAD SHX Text
0
AutoCAD SHX Text
02/12/21
AutoCAD SHX Text
FERNANDINA BEACH, FLORIDA 32034
AutoCAD SHX Text
10
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
PIRATE BASEBALL EXERCISE ROOM
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
03/22/21
AutoCAD SHX Text
ISSUE FOR CONSTRUCTION IF APPROVED BY THE NASSAU COUNTY SCHOOL BOARD
AutoCAD SHX Text
REVISED PER SCHOOL BOARD COMMENTS
AutoCAD SHX Text
2
AutoCAD SHX Text
03/25/21
AutoCAD SHX Text
10
AutoCAD SHX Text
E-1
AutoCAD SHX Text
ELECTRICAL PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
2