COMMERCIAL ROOFING
Metcom 930
0800 ROOFNZ (0800 766 369)www.metalcraftroofing.co.nz
Architectural / Specification EnquiriesPh: 09 274 0408
Mobile: 027 603 1096Email: [email protected]
00 / 14 COVER SHEET01 / 14 RIDGE WITH PROFILED APEX02 / 14 RIDGE WITH NON PROFILED APEX03 / 14 SAWTOOTH RIDGE04 / 14 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET05 / 14 FLUSH EAVE WITH PAN FIXED GUTTER06 / 14 BARGE OVERHANG07 / 14 BARGE WITH PROFILED CLADDING08 / 14 PARAPET WITH TRANSVERSE APRON09 / 14 TRANSVERSE APRON10 / 14 PARALLEL APRON11 / 14 ROOF STEP12 / 14 TRANSLUCENT SHEETS - LONG SECTION13 / 14 TRANSLUCENT SHEETS - CROSS
DETAIL LIST
* METCOM 930 MIN. ROOF PITCH = °
PRE-FINISHED RIDGE CAP FLASHING
STOPENDS TO ROOF CLADDING
METALCRAFT MSS PURLINBY ENGINEER
METALCRAFT METCOM 930ROOFING
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
BUILDING PAPER SHOWNDASHED
15.0
0°
STRUCTURAL STEELFRAMING BY ENGINEER
NOTCHED EDGEDRESSED OVERMETCOM 930 RIBS
SAFETY MESH TO WORKSAFENZ REQUIREMENTS
X
5mm
GAP
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
X
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mmX
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
RIDGE WITH PROFILED APEX
01 / 142014
* METCOM 930 MIN. ROOF PITCH = °
PRE-FINISHED RIDGE CAP FLASHING
STOPENDS TO ROOF CLADDING
METALCRAFT MSS PURLINBY ENGINEER
METALCRAFT METCOM 930ROOFING
BUILDING PAPER SHOWNDASHED
15.0
0°
STRUCTURAL STEELFRAMING BY ENGINEER
NOTCHED EDGEDRESSED OVERMETCOM 930 RIBS
SAFETY MESH TO WORKSAFENZ REQUIREMENTS
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
X
5mm
GAP
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
X
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mmX
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
RIDGE WITH NON PROFILED APEX
02 / 142014
* METCOM 930 MIN. ROOF PITCH = °
PRE-FINISHED SAWTOOTHRIDGE CAP FLASHING
BUILDING PAPER SHOWN DASHED
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
STOPENDS TO ROOF CLADDING
METALCRAFT MSS PURLIN BYENGINEER
METALCRAFT METCOM 930CLADDING
20mm CAVITY
METALCRAFT METCOM 930ROOFING
SEPARATE BATTEN ANDCLADDING WITH EPDM ASREQUIRED
15.0
0°
X
Z
BUILDING PAPER SHOWN DASHED
STRUCTURAL STEEL FRAMINGBY ENGINEER
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
HEMMED EDGE
NOTCHED EDGE DRESSEDOVER METCOM 930 RIBS
SAFETY MESH TO WORKSAFE NZREQUIREMENTS5m
m G
AP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
MIN. 70mm
X
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
MIN. 90mm
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 130mm
MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mm
MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)
X
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
SAWTOOTH RIDGE
03 / 142014
* METCOM 930 MIN. ROOF PITCH = °
PRE-FINISHED EAVEFLASHING
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
15.00°
METALCRAFT METCOM 930ROOFING
BUILDING PAPER SHOWNDASHED
FASCIA BOARD
METALCRAFT METCOM 930 CLADDINGON CAVITY
METALCRAFT MSS PURLIN BY ENGINEER
OR AS REQUIREDMIN.50mmSUGGEST MIN. 125mmDIMENSION TO SUIT
STRUCTURAL STEELFRAMING BY ENGINEER
PACKER
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
SEPARATE BATTEN ANDCLADDING WITH EPDM ASREQUIRED
OVE
RLA
P
MIN
. 35m
m
METALCRAFT BOX GUTTER125 WITH EXTERNALBRACKET
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
FLUSH EAVE WITH EXTERNAL GUTTER BRACKET
04 / 142014
* METCOM 930 MIN. ROOF PITCH = °
EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN
15.00°
PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER
SEPARATE BATTEN AND CLADDINGWITH EPDM AS REQUIRED
OR AS REQUIREDMIN.50mm SUGGEST MIN. 125mmDIMENSION TO SUIT
METALCRAFT BOX GUTTER 125WITH EXTERNAL BRACKET
METALCRAFT METCOM 930CLADDING ON CAVITY
METALCRAFT MSS PURLINBY ENGINEER
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
STRUCTURAL STEELFRAMING BY ENGINEER
PACKER
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
OVE
RLA
P
MIN
. 35m
m
PRE-FINISHED EAVEFLASHING
METALCRAFT METCOM 930ROOFING
BUILDING PAPER SHOWNDASHED
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
FLUSH EAVE WITH PAN FIXED GUTTER
05 / 142014
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
BARGE BOARD
SOFFIT LINING
METALCRAFT METCOM 930ROOFING
METALCRAFT MSS PURLIN BYENGINEER
BUILDING PAPER SHOWN DASHED
Z
Y
PRE-FINISHEDBARGE FLASHING
HEMMED EDGE
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
AT LEAST TWO CRESTS
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 70mm
Y
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 90mm
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (CORRUGATE)
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (CORRUGATE)
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Y
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 2
BARGE OVERHANG
06 / 142014
PRE-FINISHEDBARGE FLASHING
METALCRAFT METCOM 930 ROOFING
BUILDING PAPER SHOWNDASHED
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
METALCRAFT METCOM 930CLADDING
BUILDING PAPER SHOWNDASHED
METALCRAFT MSS PURLINBY ENGINEER
20mm CAVITY
Z
Y
5 GAP
20
15
ALTERNATIVE OPTIONBIRDS BEAK EDGE
PRE-FINISHED POPRIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
AT LEAST TWO CRESTS
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 70mm
Y
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
MIN. 90mm
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (CORRUGATE)
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (CORRUGATE)
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Y
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 2
BARGE WITH PROFILED CLADDING
07 / 142014
* METCOM 930 MIN. ROOF PITCH = °
BUILDING PAPERSHOWN DASHED
PRE-FINISHEDPARAPET CAPFLASHING
15.0
0°
CONTINUOUSTIMBER PACKING
MIN
. 5.0
0°
L
STOPENDS ROOFCLADDING
CONCRETE WALLBY ENGINEER
METALCRAFT MSSPURLIN BY ENGINEER
METALCRAFT METCOM 930 ROOFING
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
PRE-FINISHED FLATHEAD EXPANDINGMASONRY ANCHORSCREW WITH RUBBERWASHER FORFLASHING
PRE-FINISHED APRON FLASHING
METALCRAFT METCOM930 CLADDING ONCAVITY
SEPARATE BATTENAND CLADDING WITHEPDM AS REQUIRED
PVC CAVITY CLOSER
NOTCHED EDGE DRESSED OVERMETCOM 930 RIBS
SAFETY MESH TO WORKSAFE NZREQUIREMENTS5m
m G
AP
NG
Z
CLE
ARAN
CE
25m
m
Z
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 35mm
MIN. 75mm
MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
MIN. 50mm
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
MIN. 70mm
G
N
L
Z
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 35mm
MIN. 75mm
MIN. 200mm
MIN. 90mm
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
25mm
MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)
MIN. 150mm
MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
25mm
MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)
MIN. 200mm
MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)
G
N
L
Z
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
PARAPET WITH TRANSVERSE APRON
08 / 142014
* METCOM 930 MIN. ROOF PITCH = °
STOPENDS TO ROOFCLADDING
BUILDING PAPERSHOWN DASHED
METALCRAFT METCOM 930 ROOFING
CONCRETE WALL BYENGINEER
15.0
0°
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
METALCRAFT MSS PURLIN BY ENGINEER
CONCRETE CHASE
80.00°
10m
m
20mm
POLYSULPHIDE SEALANT
PRE-FINISHEDEXPANDING MASONRYANCHOR SCREW WITHRUBBER WASHER
PRE-FINISHEDAPRON FLASHING L
PRE-FINISHED FLASHINGOVER APRON FLASHING
PRE-FINISHED FLATHEAD EXPANDINGMASONRY ANCHORSCREW WITH RUBBERWASHER FOR FLASHING
NOTCHED EDGE DRESSED OVER METCOM930 RIBS
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
MIN
. 110
mm
MIN
. 75m
m W
IHTO
UT
HE
M E
DG
E
SU
GG
EST
MIN
. 50m
m
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°
MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)
L
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
MIN. 200mm
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 150mm
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 200mmL
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
TRANSVERSE APRON
09 / 142014
METALCRAFTMETCOM 930ROOFING
METALCRAFT MSSPURLIN BY ENGINEER
BUILDING PAPER SHOWNDASHED
MIN
. 110
mm
CONCRETE CHASE
80.00°
10m
m
20mm
POLYSULPHIDESEALANT
PRE-FINISHEDEXPANDING MASONRYANCHOR SCREW WITHRUBBER WASHER
PRE-FINISHED FLASHINGOVER APRON FLASHING
PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER
PRE-FINISHED PARALLELAPRON FLASHING
MIN
.75m
m W
ITH
OU
T H
EM
ED
GE
SU
GG
EST
MIN
.50m
m
M
PRE-FINISHED FLATHEAD EXPANDINGMASONRY ANCHORSCREW WITH RUBBERWASHER FOR FLASHING
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
5mm
GAP
SITUATION 1
1. LOW, MEDIUM, HIGH WINDZONES2. ROOF PITCH ≥ 10°
AT LEAST TWO CRESTS
SITUATION 2
1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTSM
SITUATION 3
1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES
AT LEAST TWO CRESTS
PLEASE REFER TO E2 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (CORRUGATE)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (CORRUGATE)
M
PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FUTHER INFORMATION ON FLASHING COVER WIDTHS.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 2
PARALLEL APRON
10 / 142014
* METCOM 930 MIN. ROOF PITCH = °
PRE-FINISHED FLASHING
STOPENDS TO ROOFCLADDING
METALCRAFT MSS PURLIN BY ENGINEER
METALCRAFTMETCOM 930ROOFING
PRE-FINISHED POP RIVETS BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEKSCREWS
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
BUILDING PAPER SHOWNDASHED
15.00°
15 - 20mm
MIN. 220mm
PRO
FILE DEPTH
+ 15 - 20mm
PRE-FINISHED FLAT HEADSELF DRILLING/TAPPINGSCREW WITH RUBBERWASHER FOR FLASHING
COMPRESSIBLE FOAM SEAL UNDER ROOFING.REFER TO MRM CODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.
STRUCTURAL STEELFRAMING BY ENGINEER
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
PRE-FINISHEDFLASHING
300mm 20mm GAP
200mm
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.
ScaleDate Sheet 1 : 2
ROOF STEP
11 / 142014
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
METALCRAFT METCOM930 TRANSLUCENTSHEET
FIXING WITH PROFILEDWASHER AND EPDMWASHER
METALCRAFT MSS PURLINBY ENGINEER
MID SPAN SUPPORT
PURLIN PROTECTION
PURLIN TAPE BARRIER STRIPSTRUCTURAL STEELFRAMING BY ENGINEER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 5
TRANSLUCENT SHEETS - LONG SECTION
12 / 142014
SAFETY MESH TOWORKSAFE NZREQUIREMENTS
METALCRAFT METCOM 930TRANSLUCENT SHEET
FIXING WITH PROFILEDWASHER AND EPDMWASHER
METALCRAFT MSS PURLINBY ENGINEER
MID SPAN SUPPORT
PURLIN PROTECTION
PURLIN TAPE BARRIER STRIP
METALCRAFT METCOM 930ROOFING
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
ScaleDate Sheet 1 : 5
TRANSLUCENT SHEETS - CROSS
13 / 142014
METALCRAFT METCOM 930 ROOFING
METALCRAFT MSS PURLINBY ENGINEER
FIXING WITH PROFILED WASHERAND EPDM WASHER
STRUCTURALSTEEL FRAMINGBY ENGINEER
METALCRAFT METCOM 930TRANSLUCENT SHEET
STOPEND FLASHING SEALED TOTHE SHEETING
MID SPANSUPPORT
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL ROOFINGMetcom 930
CRMCM930 ScaleDate Sheet
3D TRANSLUCENT SHEETS
14 / 142014