S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC...

25
00 / 24 COVER SHEET 01 / 24 VALLEY FLASHING 02 / 24 BARREL RIDGE 03 / 24 ANGLE RIDGE 04 / 24 FOLDED RIDGE 05 / 24 BARREL BARGE 06 / 24 ANGLE BARGE 07 / 24 FOLDED BARGE 08 / 24 BARREL CAP BARGE 09 / 24 ANGLE CAP BARGE 10 / 24 FOLDED CAP BARGE 11 / 24 TILE BATTEN LAYOUT 12 / 24 TILE BATTEN LAYOUT 13 / 24 TILE BATTEN LAYOUT 14 / 24 CHIMNEY SIDE VIEW 15 / 24 HEAD APRON 16 / 24 SIDE FLASHING 17 / 24 SECRET GUTTER 18 / 24 3D RIDGE TO BARGE JUCTION 19 / 24 3D DUTCH GABLE 20 / 24 3D APRON 21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION 22 / 24 3D CHIMNEY PENETRATION 23 / 24 3D RIDGE/BARGE FLASHINGS 24 / 24 3D DUTCH GABLE FLASHINGS DETAIL LIST RESIDENTIAL ROOFING Modena 0800 ROOFNZ (0800 766 369) www.metalcraftroofing.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] RRT30 Metalcraft Roofing

Transcript of S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC...

Page 1: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

00 / 24 COVER SHEET01 / 24 VALLEY FLASHING02 / 24 BARREL RIDGE03 / 24 ANGLE RIDGE04 / 24 FOLDED RIDGE05 / 24 BARREL BARGE06 / 24 ANGLE BARGE07 / 24 FOLDED BARGE08 / 24 BARREL CAP BARGE09 / 24 ANGLE CAP BARGE10 / 24 FOLDED CAP BARGE11 / 24 TILE BATTEN LAYOUT12 / 24 TILE BATTEN LAYOUT13 / 24 TILE BATTEN LAYOUT14 / 24 CHIMNEY SIDE VIEW15 / 24 HEAD APRON16 / 24 SIDE FLASHING17 / 24 SECRET GUTTER18 / 24 3D RIDGE TO BARGE JUCTION19 / 24 3D DUTCH GABLE20 / 24 3D APRON21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION22 / 24 3D CHIMNEY PENETRATION23 / 24 3D RIDGE/BARGE FLASHINGS24 / 24 3D DUTCH GABLE FLASHINGS

DETAIL LISTRESIDENTIAL ROOFING

Modena

0800 ROOFNZ (0800 766 369)www.metalcraftroofing.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

MetalcraftRoofing

Page 2: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

METALCRAFT MODENA™ TILE

TILE BATTEN

UNDERLAY

VALLEY GUARD

VALLEY BOARD

H

125 MM

12.5

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

VALLEY FLASHING

01 / 242015

Page 3: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

REFER TO SHEET NO. 14/24 TRANSVERSE APRON

REFER TO SHEET NO. 16/24 PARALLEL APRON

REFER TO SHEET NO. 01/24 ROOF RIDGE

L

M

X

150MM APPROX

METALCRAFT BARREL RIDGE

METALCRAFT MODENA™ TILETILE BATTEN

UNDERLAY

12.5

40MM MIN TILE TURN UP

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

BARREL RIDGE

02 / 242015

Page 4: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

155MM APPROX.

METALCRAFT ANGLE RIDGE

METALCRAFT MODENA™ TILE

TILE BATTEN

UNDERLAY

40MM MIN TILE TURN UP

12.5

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 70mm

X

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mm

MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

X

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

ANGLE RIDGE

03 / 242015

Page 5: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

METALCRAFT ANGLE RIDGE

METALCRAFT MODENA™ TILE

TILE BATTEN

UNDERLAY

40MM MIN TILE TURN UP

12.5

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

MIN. 70mm

X

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mm

MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

X

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

FOLDED RIDGE

04 / 242015

Page 6: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* ROOF PITCH FOR VALLEYS AS PER E2.

FLY RAFTER

FASCIA

UNDERLAY

SOFFIT LINING

METALCRAFTBARREL BARGE

METALCRAFTMODENA™ TILE

TILE BATTEN

SITUATION 1

MAX. CATCHMENT 25m²MIN. ROOF PITCH 8°

MIN. 250mm

MIN. 50mm

MIN. 80mm

SITUATION 2

MAX. CATCHMENT 16m²MIN. ROOF PITCH 12.5°

160mm - 249mm

MIN. 40mm

MIN. 60mm

A

B

C

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND E2 FORFURTHER INFORMATION.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

BARREL BARGE

05 / 242015

Page 7: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

FLY RAFTER

FASCIA

UNDERLAY

SOFFIT LINING

METALCRAFT ANGLEBARGE

METALCRAFTMODENA™ TILE

TILE BATTEN

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

ANGLE BARGE

06 / 242015

Page 8: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

FLY RAFTER

FASCIA

UNDERLAY

SOFFIT LINING

METALCRAFT FOLDED BARGE

METALCRAFT MODENA™ TILE

30 M

M

80 MM

130 MM

TILE BATTEN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

FOLDED BARGE

07 / 242015

Page 9: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

FLY RAFTER

UNDERLAY

SOFFIT LINING

METALCRAFT BARREL BARGE

METALCRAFT MODENA™ TILE

TILE BATTEN

METALLINE FASCIA

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

BARREL CAP BARGE

08 / 242015

Page 10: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

FLY RAFTER

UNDERLAY

SOFFIT LINING

METALCRAFT ANGLE BARGE

METALCRAFT MODENA™ TILE

TILE BATTEN

METALLINE FASCIA

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

ANGLE CAP BARGE

09 / 242015

Page 11: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

FLY RAFTER

UNDERLAY

SOFFIT LINING

METALCRAFT FOLDED BARGE

METALCRAFT MODENA™ TILE

TILE BATTEN

METALLINE FASCIA

80MM

30 M

M

130 MM

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

FOLDED CAP BARGE

10 / 242015

Page 12: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

BOTTOM COURSE 330MM

MAIN ROOF 370MM

METALCRAFT BARREL RIDGE

METALCRAFT MODENA™ TILE

TILE BATTEN

UNDERLAY

THE TILE OVERHANG INTO THERAINWATER SYSTEM WILL INCREASE WITHTHE PITCH OF THE ROOF.THE POSITION OF THE BOTTOM COURSEWILL VARY DEPENDING ON THE TYPE OFRAINWATER SYSTEM SELECTED.

FASCIA MUST NOT BE INSTALLED ATA HEIGHT GREATER THAN THAT OF THEBATTEN

150MM APPROX.

12.5

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

TILE BATTEN LAYOUT

11 / 242015

Page 13: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

BOTTOM COURSE 330MM

MAIN ROOF 370MM

METALCRAFT ANGLE RIDGE

METALCRAFT MODENA™ TILE

TILE BATTEN

UNDERLAY

THE TILE OVERHANG INTO THERAINWATER SYSTEM WILL INCREASE WITHTHE PITCH OF THE ROOF.THE POSITION OF THE BOTTOM COURSEWILL VARY DEPENDING ON THE TYPE OFRAINWATER SYSTEM SELECTED.

FASCIA MUST NOT BE INSTALLED ATA HEIGHT GREATER THAN THAT OF THEBATTEN

155MM APPROX.

40MM MIN TILE TURN UP

12.5

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetMetalcraftRoofing 1 : 5

TILE BATTEN LAYOUT

12 / 242015

Page 14: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

MAIN ROOF 370MM

BOTTOM COURSE 330MM

METALCRAFT FOLDED RIDGE

METALCRAFT MODENA™ TILE

TILE BATTEN

UNDERLAY

THE TILE OVERHANG INTO THERAINWATER SYSTEM WILL INCREASE WITHTHE PITCH OF THE ROOF.THE POSITION OF THE BOTTOM COURSEWILL VARY DEPENDING ON THE TYPE OFRAINWATER SYSTEM SELECTED.

FASCIA MUST NOT BE INSTALLED ATA HEIGHT GREATER THAN THAT OF THEBATTEN

40MM MIN TILE TURN UP

12.5

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetMetalcraftRoofing 1 : 5

TILE BATTEN LAYOUT

13 / 242015

Page 15: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

CHIMNEY CLADDING

SIDE FLASHING

METALCRAFT MODENA™ TILE

UNDERLAY

12.5

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 5

CHIMNEY SIDE VIEW

14 / 242015

Page 16: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

* MODENA™ MIN. ROOF PITCH = 12.5°

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

G

N

L

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

G

N

L

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

ROOF FRAMING

WALL FRAMING

PVC CAVITY CLOSER

WEATHERBOARDS ON CAVITY

CANT STRIP PACKER

STST OR GALV. FLAT HEADNAIL FOR FLASHING

BUILDING PAPER SHOWN DASHED

SIDE FLASHING

BUILDING PAPER OVERFLASHING SHOWN DASHED

BUILDING PAPER SHOWN DASHED

METALCRAFT MODENA™ TILE

TILE BATTEN

12.5

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 2

HEAD APRON

15 / 242015

Page 17: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

G

N

M

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (T-RIB)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (T-RIB)

G

N

M

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

SIDE FLASHING

WEATHERBOARDS ON CAVITY

CANT STRIPPACKER

BUILDING PAPER OVERFLASHING SHOWN DASHED

STST OR GALV. FLATHEAD NAIL FOR FIXING

NOG FOR FIXINGAPRON FLASHING

PVC CAVITY CLOSER

WALL FRAMING

BUILDING PAPER SHOWNDASHED

ROOF FRAMING

METALCRAFT MODENA™ TILE

TILE BATTEN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate SheetMetalcraftRoofing 1 : 2

SIDE FLASHING

16 / 242015

Page 18: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

SIDE FLASHING

WEATHERBOARDS ON CAVITY

CANT STRIPPACKER

BUILDING PAPER OVERFLASHING SHOWN DASHED

STST OR GALV. FLATHEAD NAIL FOR FIXING

NOG FOR FIXINGAPRON FLASHING

PVC CAVITY CLOSER

WALL FRAMING

BUILDING PAPER SHOWNDASHED

ROOF FRAMING

METALCRAFT MODENA™ TILE

TILE BATTEN

UNDERLAY

INTERNAL GUTTER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate SheetMetalcraftRoofing 1 : 2

SECRET GUTTER

17 / 242015

Page 19: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

PRE-FINISHED RIDGE CAPFLASHING

METALCRAFT MODENA™ ROOFING

PRE-FINISHED BARGE FLASHING

PURLIN

ROOF FRAMING

FASCIA BOARD

WALL CLADDING ON CAVITY

WALL FRAMING

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATION ONFLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30 ScaleDate SheetMetalcraftRoofing

3D RIDGE TO BARGE JUCTION

18 / 242015

Page 20: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

PRE-FINISHED RIDGE FLASHING

METALCRAFT MODENA™ ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

PRE-FINISHED BARGE FLASHING

PRE-FINISHED APRONFLASHING

PRE-FINISHED HIP FLASHING

GUTTER

FASCIA BOARD

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

WALL CLADDING ON CAVITY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30 ScaleDate SheetMetalcraftRoofing

3D DUTCH GABLE

19 / 242015

Page 21: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

GUTTER

METALCRAFT MODENA™ ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

WALL CLADDING ON CAVITY

PRE-FINISHED APRON FLASHINGWITH HEMMED EDGE

PRE-FINISHED APRON DIVERTER

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDE METALROOF FLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.

WALL CLADDING ON CAVITY

FASCIA BOARD

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30 ScaleDate SheetMetalcraftRoofing

3D APRON

20 / 242015

Page 22: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

PRE-FINISHED SOAKERFLASHING

EPDM FLEXIBLE CONE SLEEVE

MALLEABLE FLANGE, SCREWOR RIVET FIXED, AND SEALEDTO ROOFING PROFILE. FITNEOPRENE WASHERS TO ALLSCREW FIXINGS. FITTED ON45° ANGLE IN PLAN. REFER TOMRM CODE OF PRACTICEVERSION 2 2/2012.

PRE-FINISHED ROOF RIDGEFLASHING

PIPE(DIAMETER OVER 85mmDIAMETER)

METALCRAFT MODENA™ROOFING

PRE-FINISHED ROOF BARGEFLASHING

PRE-FINISHED SOAKERFLASHING LINE UNDER PRE-FINISHED ROOF RIDGE FLASHING

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDEMETAL ROOF FLASHINGS FORFURTHER INFORMATION ONFLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30 ScaleDate SheetMetalcraftRoofing

3D OVER 85mm DIAMETER PIPE PENETRATION

21 / 242015

Page 23: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

METALCRAFT MODENA™ROOFING TURN DOWN INTOGUTTER

PRE-FINISHED APRONFLASHING

WALL CLADDING ON CAVITY

PREFINISHED VALLEY GUTTERPURLIN

PRE-FINISHED SOAKERFLASHING

VALLEY BOARD

ROOF FRAMING

MIN

. 110

mm

UPS

TAN

D

MIN. 110mm UPSTANDPRE-FINISHED 1.6mmALUMINIUM WELDEDSOAKER FLASHING

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATION ONFLASHING COVER WIDTHS.

DIVERTER FLASHING ONUPPER SIDE OF CHIMNEY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30 ScaleDate SheetMetalcraftRoofing

3D CHIMNEY PENETRATION

22 / 242015

Page 24: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30 ScaleDate SheetMetalcraftRoofing

3D RIDGE/BARGE FLASHINGS

23 / 242015

OPTION 1

RIDGE CAPFLASHING

ADDITIONALSADDLEFLASHING

BARGEFLASHING

RIDGE CAPFLASHING

ADDITIONALSADDLEFLASHING

BARGEFLASHING

OPTION 2

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

Page 25: S: 5 Metalcraft Roofing01 WIP01 BIM© 2013 Drawing SetsC ...d1ki6btnkpblpf.cloudfront.net/1136/rrt30_residential-roof-modena.pdf · METALCRAFT MODENA™ TILE TILE BATTEN UNDERLAY

(3) PRE-FINISHED 3DSADDLE FLASHING

(4) PRE-FINISHEDBARGE FLASHING

(2) PRE-FINISHEDAPRON FLASHING

(1) PRE-FINISHED HIP FLASHING

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGModena™

RRT30 ScaleDate SheetMetalcraftRoofing

3D DUTCH GABLE FLASHINGS

24 / 242015

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.