Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

33
Drawing nr. Contents of drawing SPAC01-1E-EN Plinth, horizontal installation SPAC01-2E-EN Plinth, horizontal installation SPAC01-3E-EN Plinth, horizontal installation SPAC01-4E-EN Plinth, horizontal installation SPAC01-5E-EN Plinth, vertical and diagonal installation SPAC01-6E-EN Plinth, detail SPAC01-7E-EN Plinth, detail SPAC01-8E-EN Plinth, detail SPAC02-1E-EN Joint between panels, horizontal installation SPAC02-2E-EN Joint between panels, vertical and diagonal installation SPAC02-3E-EN Joint between panels, horizontal, vertical and diagonal installation SPAC03-1E-EN Vertical joint, horizontal inst., rectangle steel column, option 1 SPAC03-2E-EN Vertical joint, horizontal inst., rectangle steel column, option 2 SPAC04-1E-EN External corner, horizontal inst., rectangle steel column, option 1 SPAC04-2E-EN External corner, horizontal inst., rectangle steel column, option 2 SPAC05-1E-EN Internal corner, horizontal inst., rectangle steel column SPAC06-1E-EN Parapet, horizontal installation, side eaves SPAC06-2E-EN Parapet, horizontal installation, end eaves SPAC06-3E-EN Parapet, vertical and diagonal inst., side eaves SPAC06-4E-EN Parapet, vertical and diagonal inst., end eaves SPAC06-5E-EN Cantilever eaves, horizontal inst., side eaves, prof. sheet SPAC06-6E-EN Cantilever eaves, horizontal inst., end eaves, prof. sheet SPAC06-7E-EN Vapour barrier and insulation supp. flashing fastening SPAC07-1E-EN Window, horizontal installation SPAC07-2E-EN Window, horizontal installation SPAC07-3E-EN System window, horizontal installation, large window SPAC07-4E-EN System window, horizontal installation, large window SPAC08-1E-EN Door, horizontal installation SPAC08-2E-EN Door, horizontal installation SPAC08-3E-EN Overhead door, horizontal installation SPAC08-4E-EN Overhead door, horizontal installation City sector Building type Block Site/Reg. nr. File nr. Drawing type Contents of drawing Scale Building, Name and address Date Drawn by Designer Checked Work nr. Work nr. Drw. nr. Rev. Nr. Ruukki Construction Oy Vimpelintie 661 tel +358 2059 127 FI - 62900 ALAJÄRVI fax +358 2059 27700 FINLAND www.ruukki.com Ruukki ® Patina Panel Ruukki 07.05.2021 BASE DETAIL DRAWINGS External walls (31 pcs)

Transcript of Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Page 1: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Drawing nr. Contents of drawing

SPAC01-1E-EN Plinth, horizontal installation

SPAC01-2E-EN Plinth, horizontal installation

SPAC01-3E-EN Plinth, horizontal installation

SPAC01-4E-EN Plinth, horizontal installation

SPAC01-5E-EN Plinth, vertical and diagonal installation

SPAC01-6E-EN Plinth, detail

SPAC01-7E-EN Plinth, detail

SPAC01-8E-EN Plinth, detail

SPAC02-1E-EN Joint between panels, horizontal installation

SPAC02-2E-EN Joint between panels, vertical and diagonal installation

SPAC02-3E-EN Joint between panels, horizontal, vertical and diagonal installation

SPAC03-1E-EN Vertical joint, horizontal inst., rectangle steel column, option 1

SPAC03-2E-EN Vertical joint, horizontal inst., rectangle steel column, option 2

SPAC04-1E-EN External corner, horizontal inst., rectangle steel column, option 1

SPAC04-2E-EN External corner, horizontal inst., rectangle steel column, option 2

SPAC05-1E-EN Internal corner, horizontal inst., rectangle steel column

SPAC06-1E-EN Parapet, horizontal installation, side eaves

SPAC06-2E-EN Parapet, horizontal installation, end eaves

SPAC06-3E-EN Parapet, vertical and diagonal inst., side eaves

SPAC06-4E-EN Parapet, vertical and diagonal inst., end eaves

SPAC06-5E-EN Cantilever eaves, horizontal inst., side eaves, prof. sheet

SPAC06-6E-EN Cantilever eaves, horizontal inst., end eaves, prof. sheet

SPAC06-7E-EN Vapour barrier and insulation supp. flashing fastening

SPAC07-1E-EN Window, horizontal installation

SPAC07-2E-EN Window, horizontal installation

SPAC07-3E-EN System window, horizontal installation, large window

SPAC07-4E-EN System window, horizontal installation, large window

SPAC08-1E-EN Door, horizontal installation

SPAC08-2E-EN Door, horizontal installation

SPAC08-3E-EN Overhead door, horizontal installation

SPAC08-4E-EN Overhead door, horizontal installation

City sector

Building type

Block Site/Reg. nr. File nr.

Drawing type

Contents of drawing ScaleBuilding, Name and address

Date

Drawn by

Designer

Checked

Work nr. Work nr. Drw. nr. Rev.

Nr.

Ruukki Construction Oy

Vimpelintie 661 tel +358 2059 127

FI - 62900 ALAJÄRVI fax +358 2059 27700

FINLAND www.ruukki.com

Ruukki ® Patina Panel

Ruukki

07.05.2021

BASE DETAIL DRAWINGS

External walls (31 pcs)

Page 2: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

SANDWICH PANELS

001. Ruukki ® Patina Panel 150, 200, 230

FLASHINGS

100-103. Standard purlins and starter tracks

104-109. Purlins and other t ≥ 2 mm fastening flashings

111-119. Plinth flashings

131-159. Vertical seam-, external- and internal corner

flashings

161-179. Eave flashings

181-194. Window- and door flashings

195-199. Flashings used in uplifted roofs

FASTENERS

201. Self-drilling element screw, washer with sealing,

stainless steel

202. Self-drilling element screw, without washer,

stainless steel

215. Countersink washer

231. Flashing fastener, washer with sealing,

stainless steel

232. Flashing fastener, without washer, stainless steel

234. Flat headed flashing fastener

242. Fastener screw, without washer, stainless steel

243. Fastener screw, without washer, stainless steel

255. Spike fastener, without washer

265. Fastener screw to wood, washer with sealing,

stainless steel

270. Installation sleeve

SEALANTS AND INSULATIONS

300. Expandable sealing band

301. Plinth sealing, expanding

302. Sealing tape for flashings and for wood / steel frame

303. Sealing tape for frame

306. ISO-BUTYL self adhesive tape 2x10 mm

307. Sealing strip Nordic

308. Self adhesive butylband

309. Sealing strip corner Nordic

310. Mineral- / stonewool

312. Mineral wool band

321. Sealing compound

325. Sealing compound during installation

327. Elastic polyurethane, eg. Illbruck FM330

330. PU insulation

331. EPDM sealing

332. Separating piece EPDM

333. Separating strip EPDM

341. Plywood

342. L-profile

350. PVC tape

351. Rubber o-ring sealing

352. Lead-in rubber grommet

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC00-0E-EN

Ruukki

07.05.2021

Accessory numbers in details

Ruukki ® Patina Panel

Page 3: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

48

≥ 40

30

- +

111. COR-TEN Plinth flashing (installed simultaneously with elements)

131. COR-TEN Vertical joint flashing

231. Flashing fastener, washer with sealing *

255. /S5R48038/ Spike fastener, concrete c/c600

265. /S3H55042WA4B/ Fastener *, wood c/c600

312. /EAWS___/ Mineral wool band

341. Plywood, if necessary

Ruukki's delivery

or

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-1E-EN

Ruukki

07.05.2021

1:2

Option 1

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

255

100

312

001

131

265

SPAC01-6E

341

111

001. Ruukki ® Patina Panel

308

350

308. Self adhesive butylband

350. PVC tape

301

231

301. /EA3PSE/ Plinth sealing, expanding

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

100. /EA1U___/ Starter track

*Screw material stainless steel

Page 4: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

48

≥ 40

30

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-2E-EN

Ruukki

07.05.2021

1:2

Option 2

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

100. /EA1U___/ Starter track

306. ISO-BUTYL self adhesive tape 2x10 mm

308. Self adhesive butylband

312. /EAWS___/ Mineral wool band

350. PVC tape

Ruukki's delivery

or

115. Support flashing (installed simultaneously with elements)

131. COR-TEN Vertical joint flashing

255. /S5R48038/ Spike fastener, concrete c/c600

001. Ruukki ® Patina Panel

100

312

265

001

131

SPAC01-6E

255

115

111

308

306

350

111. COR-TEN Plinth flashing (installed simultaneously with elements)

301. /EA3PSE/ Plinth sealing, expanding

301

255

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

265. /S3H55042WA4B/ Fastener *, wood c/c600

*Screw material stainless steel

Page 5: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

48

≥ 40

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-3E-EN

Ruukki

07.05.2021

1:2

Option 3

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

312. /EAWS___/ Mineral wool band

131. COR-TEN Vertical joint flashing

255. /S5R48038/ Spike fastener, concrete c/c600

Ruukki's delivery

or

30

001. Ruukki ® Patina Panel

001

131

SPAC01-7E

231

116

255

115

306

100

312

332

100. /EA1U___/ Starter track

115. Support flashing (installed simultaneously with elements)

116. COR-TEN Plinth flashing (can be installed after element installation)

306. ISO-BUTYL self adhesive tape 2x10 mm

321. /EA3SM310___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

321

301. /EA3PSE/ Plinth sealing, expanding

255

265

301

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

265. /S3H55042WA4B/ Fastener *, wood c/c600

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 6: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-4E-EN

Ruukki

07.05.2021

1:2

Option 3

Horizontal installation, plinth, vertical section

Ruukki ® Patina Panel

Ruukki's delivery

48

≥ 40

30

001. Ruukki ® Patina Panel

001

131

SPAC01-7E

116

255

115

306

100

312

333

321

312. /EAWS___/ Mineral wool band

131. COR-TEN Vertical joint flashing

255. /S5R48038/ Spike fastener, concrete c/c600

301. /EA3PSE/ Plinth sealing, expanding

or

100. /EA1U___/ Starter track

115. Support flashing (installed simultaneously with elements)

116. COR-TEN Plinth flashing (can be installed after element installation)

306. ISO-BUTYL self adhesive tape 2x10 mm

321. /EA3SM310___/ Sealing compound

333. /CA3SE410/ Separating strip EPDM

255

265

301

Special care should be taken

to ensure the smoothness of the

top of plinth, tolerance ± 5 mm

265. /S3H55042WA4B/ Fastener *, wood c/c600

*Screw material stainless steel

Page 7: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

≥ 3

0

301

255

234

118

326

105

302

234

001

131

SPAC01-8E

326

201

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-5E-EN

Ruukki

07.05.2021

1:2

Plinth, vertical section

vertical and diagonal installation

Ruukki ® Patina Panel

118. Cover flashing, according to project

Ruukki's delivery

105. /EA1L75/ Support L-purlin, (t=3mm)

255. /S5R48038/ Spike fastener, concrete c/c600

302. /EA3SS410/ Sealing tape

321. /EA3SM310___/ Sealing compound

326. /EA3SM310___/ Sealing compound during

234. Flat head flashing fastener

inst. to outer female groove full length of element

and inner female groove 60 mm from panel end

48

231

116

255

115

306

332

321

≥ 40

001. Ruukki ® Patina Panel

352/332

115. Support flashing (installed with elements)

116. COR-TEN Plinth flashing (can be installed afterwards)

131. COR-TEN Vertical joint flashing

301. /EA3PSE/ Plinth sealing, expanding

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 8: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-6E-EN

Ruukki

07.05.2021

1:1

Horizontal installation, plinth, detail

Ruukki ® Patina Panel

Elastic sealing strip,

installed on site

Drain holes in the corner of

starter track Ø12 c/c300

Special care should be taken to ensure the

smoothness of the top of plinth, tolerance ± 5 mm

Page 9: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-7E-EN

Ruukki

07.05.2021

1:1

Horizontal installation, plinth, detail

Ruukki ® Patina Panel

Elastic sealing strip,

installed on site

Drain holes in the corner of

starter track Ø12 c/c300

Special care should be taken to ensure the

smoothness of the top of plinth, tolerance ± 5 mm

Page 10: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC01-8E-EN

Ruukki

07.05.2021

1:1

Plinth, detail

vertical and diagonal installation

Ruukki ® Patina Panel

Special care should be taken to ensure the

smoothness of the top of plinth, tolerance ± 5 mm

Sealing compound to female groove

during installation

Sealing compound

after installation

Page 11: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC02-1E-EN

Ruukki

07.05.2021

1:2

Vertical section

Horizontal installation, joint between panels,

Ruukki ® Patina Panel

12

00

±2

12

00

±2

Elastic sealing strip,

installed in the factory

Protective film

is installed in the factory

Ruukki's delivery

325. /EA3SM310___/ Sealing compound during installation to outer female groove

to length equivalent to vertical joint flashing width and inner female groove in length of sealing

001

325

001

001. Ruukki ® Patina Panel

Elastic sealing strip,

installed on site

Page 12: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

-

+

326. /EA3SM310___/ Sealing compound during installation to outer female groove in full length of element and

Ruukki's delivery

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC02-2E-EN

Ruukki

07.05.2021

1:2

Joint between panels, horizontal section

diagonal installation

Ruukki ® Patina Panel vertical- and

inner female groove 60 mm from panel end

001

326

Protective film

is installed in the outer groove

joint as a standard in the factory

Elastic sealing strip,

installed in the factory

001

1200 ±21200 ±2

001. Ruukki ® Patina Panel

Elastic sealing strip,

installed on site

Page 13: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC02-3E-EN

Ruukki

07.05.2021

1:1

Joint between panels

horizontal, vertical- and diagonal installation

Ruukki ® Patina Panel

Horizontal installation:

Sealing compound during installation to outer female groove. Length equivalent to width of vertical joint

flashing. It is important that the groove is completely filled with mastic sealant, i.e. it must be applied before

interlocking the joint.

Vertical installation:

Sealing compound during installation to outer female groove in full length of panel and inner female groove

60 mm in length. It is important that the groove is completely filled with mastic sealant, i.e. it must be applied

before interlocking the joint.

Vertical joint flashing

- +

Sealing

Vertical joint flashing

Separating piece EPDM

Sealing compound during installation,

length equivalent to width of vertical joint flashing

-

+

Protective film is installed in the outer

groove joint as a standard in the factory.

Elastic sealing strip is installed on site.

Sealing compound during installation,

length equivalent to width of vertical joint flashing

Page 14: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC03-1E-EN

Ruukki

07.05.2021

1:2

Vertical joint, horizontal section, option 1

Horizontal installation

Ruukki ® Patina Panel

303. /EA3SS1210/ Sealing tape

Ruukki's delivery

325. /EA3SM310___/ Sealing compound during inst.

to outer female groove in length equivalent to

vertical joint flashing width and inner female groove

in length of sealing

+

-

001. Ruukki ® Patina Panel

325

325

231

332/333

131

312

307

201

001

321

352/332

131. COR-TEN Vertical joint flashing

307. /EA3JSN7525/ Sealing strip Nordic

312. /EAWS___/ Mineral wool band

321. /EA3SM310___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

≥ 30

≥ 50

30

303

327

327. Elastic polyurethane foam

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 15: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Ruukki's delivery

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC03-2E-EN

Ruukki

07.05.2021

1:2

Vertical joint, horizontal section, option 2

Horizontal installation

Ruukki ® Patina Panel

215, requires preholes 27 mm

+

-

001. Ruukki ® Patina Panel

325

231

332/333

131

312

307

202

001

321

351

215. /EA2W40-910S/ Countersunk washer

325. /EA3SM310___/ Sealing compound during inst.

to outer female groove in length equivalent to

vertical joint flashing width and inner female groove

in length of sealing

131. COR-TEN Vertical joint flashing

307. /EA3JSN7525/ Saling strip Nordic

312. /EAWS___/ Mineral wool band

321. /EA3SM310___/ Sealing compound

325

≥ 30

≥ 50

30

303

327

303. /EA3SS1210/ Sealing tape 332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

351. Rubber o-ring sealing

327. Elastic polyurethane foam

202. Self-drilling element screw, without washer *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 16: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

+

-

b

50

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC04-1E-EN

Ruukki

07.05.2021

1:2

External corner, horizontal section, option 1

Horizontal installation

Ruukki ® Patina Panel

141. COR-TEN External corner flashing

Ruukki's delivery

312. /EAWS___/ Mineral wool band

325. /EA3SM310___/ Sealing compound during inst.

to outer female groove in length equivalent to

Facing sheet cutting at site

by length b = element thickness

309. /EA3JSCN30025/ Sealing strip corner Nordic

vertical joint flashing width and inner female groove

in length of sealing

231

332/333

201

141

001

312

325

309

001. Ruukki ® Patina Panel

321

352/332

321. /EA3SM310___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

30 ≥ 30

327

303

303. /EA3SS1210/ Sealing tape 327. Elastic polyurethane foam

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 17: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC04-2E-EN

Ruukki

07.05.2021

1:2

External corner, horizontal section, option 2

Horizontal installation

Ruukki ® Patina Panel

Ruukki's delivery

145. /EA1EC10-__/External corner flashing, t =1 /1.2 mm

Facing sheet cutting at site

by length b = element thickness

+

-

b

50

231

332/333

201

131

001

312

325

309

001. Ruukki ® Patina Panel

321

352/332

145

131. COR-TEN External corner flashing

312. /EAWS___/ Mineral wool band

309. /EA3JSCN30025/ Sealing strip corner Nordic

325. /EA3SM310___/ Sealing compound during inst.

to outer female groove in length equivalent to

vertical joint flashing width and inner female groove

in length of sealing

321. /EA3SM310___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

30 ≥ 30

327

303

303. /EA3SS1210/ Sealing tape 327. Elastic polyurethane foam

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 18: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC05-1E-EN

Ruukki

07.05.2021

1:5

Internal corner, horizontal section

Horizontal installation

Ruukki ® Patina Panel

-

+

+

001. Ruukki ® Patina Panel

≥ 30

≥ 50

001

234

242

201

312

325

231

332/333

201

312

307

151

325

325

50

321

352/332

151. COR-TEN Internal corner flashing

152. Internal corner flashing, t = 0.6 mm, according to project

234. Flat head flashing fastener

242. Fastener screw, without washer

307. /EA3JSN7525/ Sealing strip Nordic

312. /EAWS___/ Mineral wool band

321. /EA3SM310___/ Sealing compound

325. /EA3SM310___/ Sealing compound during installation to outer female groove

332. /CA3SP814/ Separating piece EPDM

352. Lead-in rubber grommet

in length equivalent to vertical joint flashing width and inner female groove in length of sealing

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

30

303

327

303. /EA3SS1210/ Sealing tape

327. Elastic polyurethane foam

Screw drilling tip can be

cut off after installation

152 if necessary

152 if necessary

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 19: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC06-1E-EN

Ruukki

07.05.2021

1:5

Bitumen roofing felt, vertical section

Horizontal installation, parapet, side eaves

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

- +

265

001

131

163

232

161

312

101

162

311

171

350

332/333

306

101. /EA1D___/ Purlin

131. COR-TEN Vertical joint flashing

162. Cover flashing, t = 0.6 mm, according to project

163. Perforated storm flashing, t = 0.6 mm, acc. to project

161. COR-TEN Eave flashing, t = 0.7 mm, acc. to project

171. Insulation support flashing, t = 0.6 mm,

according to project

311. Mineral wool

312. /EAWS___/ Mineral wool band

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

Horizontal

support studwork

Plywood

Vertical

support studwork

Waterproofing is not fastened

to structures below L~400 mm

Reverse dip is made of Leca-gravel,

Siporex chips or woolsheets cut to form

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Secondary steel supports (t-steel)

for the element according to

structural designer.

Vapour barrier and insulation support

fastening, check SPAC06-7E

of the panel)

232. Flashing fastener, without washer *

265. Fastener screw to wood, washer with sealing *

*Screw material stainless steel

Page 20: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC06-2E-EN

Ruukki

07.05.2021

1:5

Bitumen roofing felt, vertical section

Horizontal installation, parapet, end eaves

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

001

131

312

101

265

311

172

332/333

163

232

161

306

350

101. /EA1D___/ Purlin

131. COR-TEN Vertical joint flashing

163. Perforated storm flashing, t = 0.6 mm, acc. to project

161. COR-TEN Eave flashing, t = 0.7 mm, acc. to project

172. Insulation support flashing, t = 0.6 mm,

according to project

311. Mineral wool

312. /EAWS___/ Mineral wool band

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

Ruukki's delivery

Horizontal

support studwork

Plywood

Vertical

support studwork

Waterproofing is not fastened

to structures below L~400 mm

Ventilation grooves

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Secondary steel supports (t-steel)

for the element according to

structural designer.

Vapour barrier and insulation support

fastening, see SPAC06-7E

of the panel)232. Flashing fastener, without washer *

265. Fastener screw to wood, washer with sealing *

*Screw material stainless steel

Page 21: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

- +

102. /EA1EP___/ Purlin

104. Flashing for fastening / insulation support flashing,

162. Cover flashing, t = 0.6 mm, according to project

Ruukki's delivery

163. Perforated storm flashing, t = 0.6 mm, acc. to project

161. Eave flashing, t = 0.6 mm, according to project

326. /EA3SM310___/ Sealing compound during inst.

to outer male groove full length of element and

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Vapour barrier and insulation support

fastening, see SPAC06-7E

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC06-3E-EN

Ruukki

07.05.2021

1:5

Bitumen roofing felt, vertical section

diagonal inst. Parapet, side eaves

Ruukki ® Patina Panel vertical- and

t=3 mm, according to project

inner female groove 60 mm in length of element

001

201

131

326

326

102

Horizontal

support studwork

Plywood

Vertical

support studwork

162

Waterproofing is not fastened

to structures below L~400 mm

311

Reverse dip is made of Leca-gravel,

Siporex chips or woolsheets cut to form

104

242

163

161

306

232

350

265

332/333

321

332/333

352/332

001. Ruukki ® Patina Panel

131. COR-TEN Vertical joint flashing (horizontal inst.)

306. ISO-BUTYL self adhesive tape 2x10 mm

321. /EA3SM310___/ Sealing compound

311. Mineral wool

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

of the panel)

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

232. Flashing fastener, without washer *

265. Fastener screw to wood, washer with sealing *

242. Fastener screw, without washer *

*Screw material stainless steel

Page 22: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

- +

102. /EA1EP___/ Purlin

106. Flashing for fastening / insulation support flashing,

Ruukki's delivery

163. Storm flashing, t = 0.6 mm, according to project

161. Eave flashing, t = 0.6 mm, according to project

311. Mineral wool

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC06-4E-EN

Ruukki

07.05.2021

1:5

Bitumen roofing felt, vertical section

diagonal inst. Parapet, end eaves

Ruukki ® Patina Panel vertical- and

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Vapour barrier and insulation support

fastening, see SPAC06-7E

t=3 mm, according to project

326. /EA3SM310___/ Sealing compound during inst.

to outer male groove full length of element and

inner female groove 60 mm in length of element

102

001

326

326

Horizontal

support studwork

Plywood

Vertical

support studwork

Waterproofing is not fastened

to structures below L~400 mm

311

106

242

Ventilation grooves

265

332/333

163

232

161

306

350

201

131

321

332/333

352/332

001. Ruukki ® Patina Panel

131. COR-TEN Vertical joint flashing (horizontal inst.)

306. ISO-BUTYL self adhesive tape 2x10 mm

321. /EA3SM310___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

of the panel)

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

232. Flashing fastener, without washer *

242. Fastener screw, without washer *

265. Fastener screw to wood, washer with sealing *

*Screw material stainless steel

Page 23: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC06-5E-EN

Ruukki

07.05.2021

1:5

Rofiled sheet roof deck, vertical section

Horizontal installation, cantilever eaves, side eaves

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

167

171

311

312

101

232

001

131

167

350

231

332/333

321

311. Mineral wool

Ruukki's delivery

171. Insulation support flashing, t = 0.6 mm, according to project

164. COR-TEN Storm flashing, t = 0.7 mm, according to project

131. COR-TEN Vertical joint flashing

312. /EAWS___/ Mineral wool band

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

101. /EA1D___/ Purlin

167. COR-TEN Eave flashing, t = 0.7 mm, according to project

321. /EA3SM310___/ Sealing compound

Plywood

Wooden wedge

Load bearing profiled sheet

sealed with a flashing on both sides

Perforated profiled sheet

Water drainage system

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Element is cut at the point where it intersects

with the steel structure. Vapour barrier is

taped around the steel.

Vapour barrier and insulation support

fastening, see SPAC06-7E

of the panel)

232. Flashing fastener, without washer *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 24: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC06-6E-EN

Ruukki

07.05.2021

1:5

Rofiled sheet roof deck, vertical section

Horizontal installation, cantilever eaves, end eaves

Ruukki ® Patina Panel

172

311

312

101

232

168

265

131

001

001. Ruukki ® Patina Panel

350

231

332/333

321

311. Mineral wool

Ruukki's delivery

172. Insulation support flashing, t = 0.6 mm, according to project

312. /EAWS___/ Mineral wool band

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

101. /EA1D___/ Purlin

168. COR-TEN Eave flashing, t = 0.7 mm, according to project

321. /EA3SM310___/ Sealing compound

Insulation thickness is dimensioned

according to project.

Supports and fastening of profiled

sheet according to structural

designer.

Element is cut at the point where it intersects

with the steel structure. Vapour barrier is

taped around the steel.

Vapour barrier and insulation support

fastening, see SPAC06-7E

Ventilation

grooves

Load bearing profiled sheet

sealed with

a flashing on both sides

Plywood

164. COR-TEN Storm flashing, t = 0.7 mm, according to project

131. COR-TEN Vertical joint flashing

of the panel)

232. Flashing fastener, without washer *

231. Flashing fastener, washer with sealing *

265. Fastener screw to wood, washer with sealing *

*Screw material stainless steel

Page 25: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC06-7E-EN

Ruukki

07.05.2021

1:2

and insulation support flashing fastening

Horizontal installation, Vapour barrier

Ruukki ® Patina Panel

232

232

173

302

171. Insulation support flashing, t = 0.6 mm, according to project

172. Insulation support flashing, t = 0.6 mm

173. Flat flashing to vapour barrier fastening, t = 0.6 mm, according to project

232. Flashing fastener, without washer

302. /EA3SS410/ Sealing tape, between panel and vapour barrier

Ruukki's delivery

171 / 172, to be cut at panel support

Vapour barrier movable joint

Page 26: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC07-1E-EN

Ruukki

07.05.2021

1:5

Window, vertical section

Horizontal installation

Ruukki ® Patina Panel

- +

001. Ruukki ® Patina Panel

321

234

234

321

103

001

231

181

231

186

187

231

306

350

350

332/333

332/333

306

188

186. Support- / cover flashing, t = 0.6 mm, acc. to project

187. COR-TEN External window sill, t=0.7 mm

Ruukki's delivery

321. /EA3SM310___/ Sealing compound

181. COR-TEN Drip flashing, t = 0.7 mm, acc. to project

103. /EA1W___/ Window purlin

188. Support- / cover flashing, t = 0.6 mm, acc. to project

234. Flat head flashing fastener

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape (between purlin and external facing

/333. /CA3SE410/ Separating strip EPDM

300

300. /EA3SPBSK___/ Expandable sealing band

Note! Openings must be taken into account in dimensioning of elements.

Note! When thermal purlin (window purlin, for example) is used around the opening, the thermal holes of the purlin must

be sealed with tape (aluminium tape, for example) from the inside of the purlin to ensure tightness of the purlin.

Note! Remember to seal the grooves of the elements joining the window during the installation with elastic sealant to

outer female groove to length equivalent to vertical joint flashing widht).

Supporting structures, if necessary, according to structural designer .

of the panel)

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 27: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC07-2E-EN

Ruukki

07.05.2021

1:2

Window, horizontal section

Horizontal installation

Ruukki ® Patina Panel

-

+

001. Ruukki ® Patina Panel

001

321

234

103

188

231

231

325

325

332/333

306

350

332/333

321

188. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

234. Flat head flashing fastener

321. /EA3SM310___/ Sealing compound103. /EA1W___/ Window purlin

Ruukki's delivery

325. /EA3SM310___/ Sealing compound

during inst. to outer and inner female grooves

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape (between purlin and external facing

300

300. /EA3SPBSK___/ Expandable sealing band

Note! Openings must be taken into account in dimensioning of elements.

Note! When thermal purlin (window purlin, for example) is used around the opening, the thermal holes of the purlin must

be sealed with tape (aluminium tape, for example) from the inside of the purlin to ensure tightness of the purlin.

Note! Remember to seal the grooves of the elements joining the window during the installation with elastic sealant to

outer female groove to length equivalent to vertical joint flashing widht.

Supporting structures, if necessary, according to structural designer.

of the panel)

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 28: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

≥ 5

0≥ 5

0

- +

321

321

001

321

231

201

182

183

321

321

231

201

185

332/333

350

001. Ruukki ® Patina Panel

332/333

231

332/333

350

306

352/332

352/332

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC07-3E-EN

Ruukki

07.05.2021

1:5

vertical section, large window, supporting structure

Horizontal installation, system window,

Ruukki ® Patina Panel

Note! Openings must be taken into account in dimensioning of elements.

Note! System window is installed during installation of elements. Fastening according to window manufacturers

instructions.

Note! Remember to seal the grooves of the elements joining the window during the installation with sealant to outer

female groove to length equivalent to vertical joint flashing and inner female groove in length of sealing (SPAC02-1E).

Supporting structures according to structural designer.

Ruukki's delivery

183. Storm flashing, t = 0.6 mm, according to project

185. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

321. /EA3SM310___/ Sealing compound

182. COR-TEN Drip flashing, t = 0.7 mm, acc. to project 306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

350. PVC tape

/333. /CA3SE410/ Separating strip EPDM

352. Lead-in rubber grommet

300

300

300. Expandable sealing band included in

Ruukki energy window delivery

303

303

303. /EA3SS1210/ Sealing tape

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 29: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

≥ 50

-

+323

185

201

001

325

321

350

332/333

231

321

332/333

325

001. Ruukki ® Patina Panel

352/332

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC07-4E-EN

Ruukki

07.05.2021

1:2

horizontal section, large window

Horizontal installation, system window,

Ruukki ® Patina Panel

Note! Openings must be taken into account in dimensioning of elements.

Note! System window is installed during installation of elements. Fastening according to window manufacturers

instructions.

Note! Remember to seal the grooves of the elements joining the window during the installation with sealant to outer

female groove to length equivalent to vertical joint flashing and inner female groove in length of sealing (SPAC02-1E).

Supporting structures according to structural designer.

185. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

Ruukki's delivery

321. /EA3SM310___/ Sealing compound

325. /EA3SM310___/ Sealing compound

during inst. to outer and inner female grooves

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape

352. Lead-in rubber grommet

300

300. Expandable sealing band included in

Ruukki energy window delivery

303. /EA3SS1210/ Sealing tape

303

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

Page 30: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC08-1E-EN

Ruukki

07.05.2021

1:2

Door, vertical section

Horizontal installation

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

321

310

101

191

232

234

321

001

231

232

181

189

332/333

350

321

306

321

350

191. Cover flashing, t = 0.6 mm,

231. Flashing fastener, washer with sealing

321. /EA3SM310___/ Sealing compound

310. Mineral wool

181. COR-TEN Drip flashing, t = 0.7 mm,

101. EA1D___/ Door jamb batten

189. Cover flashing, t = 0.6 mm,

234. Flat head flashing fastener

Ruukki's delivery

according to project

according to project

according to project

306. ISO-BUTYL self adhesive tape 2x10 mm

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape (between purlin and external facing

300

300. /EA3SPBSK___/ Expandable sealing band

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPAC02-1E).

Supporting structures, if necessary, according to structural designer.

of the panel)

231. Flashing fastener, washer with sealing *

*Screw material stainless steel

232. Flashing fastener, without washer *

Page 31: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

-

+

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC08-2E-EN

Ruukki

07.05.2021

1:2

Door, horizontal section

Horizontal installation

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

234

321

232

310

191

101

321

192

232

231

001

325

332/333

321

350

231. Flashing fastener, washer with sealing

232. Flashing fastener, without washer

321. /EA3SM310___/ Sealing compound

310. Mineral wool

191. Cover flashing, t = 0.6 mm, according to project

192. COR-TEN cover flashing, t = 0.7 mm, acc. to project

101. EA1D___/ Door jamb batten

312. /EAWS___/ Mineral wool band

234. Flat head flashing fastener

Ruukki's delivery

325. /EA3SM310___/ Sealing compound

during inst. to outer and inner female grooves

332. /CA3SP814/ Separating piece EPDM

333. /CA3SE410/ Separating strip EPDM

350. PVC tape (between purlin and external facing

300

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPAC02-1E).

Supporting structures, if necessary, according to structural designer.

of the panel)

231. Flashing fastener, washer with sealing *

232. Flashing fastener, without washer *

*Screw material stainless steel

Page 32: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

- +

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC08-3E-EN

Ruukki

07.05.2021

1:5

Overhead door, vertical section

Horizontal installation

Ruukki ® Patina Panel

001. Ruukki ® Patina Panel

303

330

193

201

231

332/333

001

330

342

331

101

232

312

194

350

321

332/333

321

352/332

201. Self-drilling element screw, washer with sealing

321. /EA3SM310___/ Sealing compound

231. Flashing fastener, washer with sealing

193. COR-TEN Drip- / cover flashing, t = 0.7 mm, acc. to project

Ruukki's delivery

330. PU insulation

331. EPDM sealing

342. L-profile

101. EA1D___/ Door jamb batten

232. Flashing fastener, without washer

312. /EAWS___/ Mineral wool band

194. Drip- / cover flashing, t = 0.6 mm, acc. to project

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape (between purlin and external

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPAC02-1E).

Supporting structures according to structural designer.

303. /EA3SS1210/ Sealing tape

352. Lead-in rubber grommet

facing of the panel)

201. Self-drilling element screw, washer with sealing *

231. Flashing fastener, washer with sealing *

232. Flashing fastener, without washer *

*Screw material stainless steel

Page 33: Ruukki ® Patina Panel BASE DETAIL DRAWINGS External …

+

-

Rev.

Date

Scale

Drawn by

Drawing nr.

File nr.

Rev. date

Building

Copyright © Ruukki Construction Oy. Allowed only for designs with Ruukki's products.

Work nr.

Contents of drawing

SPAC08-4E-EN

Ruukki

07.05.2021

1:5

Overhead door, horizontal section

Horizontal installation

Ruukki ® Patina Panel

001

231

201

193

330

342

331

101

312

232

325

332/333

194

330

350

001. Ruukki ® Patina Panel

321

332/333

321

352/332

231. Flashing fastener, washer with sealing

193. COR-TEN Cover flashing, t = 0.7 mm, acc. to project

201. Self-drilling element screw, washer with sealing

302. /EA3SS410/ Sealing tape

Ruukki's delivery

330. PU insulation

331. EPDM sealing

342. L-profile

232. Flashing fastener, without washer

101. EA1D___/ Door jamb batten

312. /EAWS___/ Mineral wool band

325. /EA3SM310___/ Sealing compound

during inst. to outer and inner female grooves

194. Drip- / cover flashing, t = 0.6 mm, acc. to project

321. /EA3SM310___/ Sealing compound

332. /CA3SP814/ Separating piece EPDM

/333. /CA3SE410/ Separating strip EPDM

350. PVC tape (between purlin and external facing

Note! Openings must be taken into account in dimensioning of elements.

Note! Remember to seal the grooves of the elements joining the door during the installation with elastic sealant to outer

female groove to length equivalent to vertical joint flashing widht (SPAC02-1E).

Supporting structures according to structural designer.

303

352. Lead-in rubber grommet

of the panel)

231. Flashing fastener, washer with sealing *

201. Self-drilling element screw, washer with sealing *

232. Flashing fastener, without washer *

*Screw material stainless steel