R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring...

12
Radiomonitoring & Radiolocation Data Sheet | 01.02 R&S®EB500 Monitoring Receiver Specifications

Transcript of R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring...

Page 1: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Ra

diom

onito

ring &

Rad

iolo

catio

n

Data

She

et |

01.0

2R&S®EB500 Monitoring ReceiverSpecifications

Page 2: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

2 Rohde & Schwarz R&S®EB500 Monitoring Receiver

CONTENTS Definitions ....................................................................................................................................................................... 3 Specifications.................................................................................................................................................................. 4

Frequency ...............................................................................................................................................................................................4 Linearity ..................................................................................................................................................................................................4 Interference rejection ..............................................................................................................................................................................4 Noise figure120.......................................................................................................................................................................................4 Sensitivity................................................................................................................................................................................................5 Demodulation ..........................................................................................................................................................................................5 IF bandwidth............................................................................................................................................................................................5 ADC resolution........................................................................................................................................................................................5 Level and offset measurement................................................................................................................................................................6 IF panorama............................................................................................................................................................................................6 Modulation measurement (with R&S®EB500-IM option) .........................................................................................................................6 Scan characteristics................................................................................................................................................................................6 Antenna input..........................................................................................................................................................................................7 Input and output ......................................................................................................................................................................................7 General data ...........................................................................................................................................................................................8

Ordering information ...................................................................................................................................................... 9

Page 3: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

Rohde & Schwarz R&S®EB500 Monitoring Receiver 3

Definitions General Product data applies under the following conditions:

• Three hours storage at ambient temperature followed by 30 minutes warm-up operation • Specified environmental conditions met • Recommended calibration interval adhered to • All internal automatic adjustments performed, if applicable

Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <, ≤, >, ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable.

Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design.

Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value.

Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production.

Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples.

Uncertainties Represent limits of measurement uncertainty for a given measurement. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear.

Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.

Page 4: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Specifications

Frequency base unit 20 MHz to 3.6 GHz with R&S®EB500-HF option 9 kHz to 3.6 GHz with R&S®EB500-FE option 20 MHz to 6 GHz

Frequency range

with R&S®EB500-HF and R&S®EB500-FE option

9 kHz to 6 GHz

Frequency resolution 1 Hz BFO 0 Hz to ±8 kHz Frequency accuracy ≤ 1 × 10–6 Input for external reference 10 MHz Synthesizer settling time ≤ 1 ms, 900 µs (typ.)

9 kHz to 32 MHz ≤ –130 dBc (1 Hz) at 1 kHz offset, –140 dBc (1 Hz) (typ.)

20 MHz to 650 MHz ≤ –120 dBc (1 Hz) at 10 kHz offset

Oscillator phase noise

650 MHz to 6 GHz ≤ –103 dBc (1 Hz) at 10 kHz offset

Linearity Second-order intercept point (SOI)

low distortion mode 1 MHz ≤ f ≤ 32 MHz ≥ 70 dBm, 80 dBm (typ.)

9 kHz to 32 MHz

normal mode ≥ 55 dBm, 70 dBm (typ.) low distortion mode 50 dBm (typ.) 20 MHz to 6 GHz normal mode 40 dBm (typ.)

Third-order intercept point (TOI) low distortion mode (150 kHz spacing at –5 dBm)

1 MHz ≤ f ≤ 32 MHz ≥ 30 dBm, 35 dBm (typ.) 9 kHz ≤ f < 1 MHz 30 dBm (typ.)

normal mode (150 kHz spacing at –15 dBm) 1 MHz ≤ f ≤ 32 MHz ≥ 20 dBm, 28 dBm (typ.)

9 kHz to 32 MHz

9 kHz ≤ f < 1 MHz 20 dBm (typ.) low distortion mode (2 MHz spacing at –20 dBm)

20 MHz ≤ f ≤ 650 MHz ≥ 15 dBm, 19 dBm (typ.) 650 MHz ≤ f ≤ 6 GHz ≥ 10 dBm, 14 dBm (typ.)

normal mode (2 MHz spacing at –30 dBm) 20 MHz ≤ f ≤ 650 MHz ≥ 7 dBm, 10 dBm (typ.)

20 MHz to 6 GHz

650 MHz ≤ f ≤ 6 GHz ≥ 0 dBm, 5 dBm (typ.)

Interference rejection 9 kHz ≤ f ≤ 32 MHz direct reception (no image frequency

present) Image rejection

20 MHz ≤ f ≤ 6 GHz ≥ 80 dB, 90 dB (typ.) 9 kHz ≤ f ≤ 32 MHz direct reception (no IF present) IF rejection 20 MHz ≤ f ≤ 6 GHz ≥ 80 dB

Noise figure normal mode

400 kHz ≤ f ≤ 30 MHz ≤ 15 dB, 12 dB (typ.) f > 30 MHz ≤ 18 dB, 16 dB (typ.)

9 kHz to 32 MHz

low distortion mode 20 dB (typ.) normal mode ≤ 14 dB, 10 dB (typ.) 20 MHz to 3.6 GHz low distortion mode 20 dB (typ.)

3.6 GHz to 6 GHz normal mode ≤ 20 dB, 15 dB (typ.)

Page 5: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

Rohde & Schwarz R&S®EB500 Monitoring Receiver 5

Sensitivity Sensitivity (demodulation) measurement using telephone filter in line

with ITU-T normal mode

AM: bandwidth = 6 kHz, SINAD = 12 dB, fmod = 1 kHz, m = 0.5

≤ –107 dBm (≤ 1 µV), 400 kHz ≤ f ≤ 32 MHz

FM: bandwidth = 9 kHz, SINAD = 20 dB, fmod = 1 kHz, deviation = 3 kHz

≤ –107 dBm (≤ 1 µV), 400 kHz ≤ f ≤ 32 MHz

SSB: bandwidth = 2.4 kHz, SINAD = 12 dB, ∆f = 1 kHz

≤ –113 dBm (≤ 0.5 µV), 400 kHz ≤ f ≤ 32 MHz

9 kHz to 32 MHz

CW: bandwidth = 600 Hz, SINAD = 12 dB

≤ –119 dBm (≤ 0.25 µV), 400 kHz ≤ f ≤ 32 MHz

normal mode AM: bandwidth = 6 kHz, SINAD = 12 dB, fmod = 1 kHz, m = 0.5

≤ –107 dBm (≤ 1 µV)

FM: bandwidth = 15 kHz, SINAD = 20 dB, fmod = 1 kHz, deviation = 5 kHz

≤ –107 dBm (≤ 1 µV)

SSB: bandwidth = 2.4 kHz, SINAD = 12 dB, ∆f = 1 kHz

≤ –113 dBm (≤ 0.5 µV)

20 MHz to 3.6 GHz

CW: bandwidth = 600 Hz, SINAD = 12 dB

≤ –119 dBm (≤ 0.25 µV)

normal mode AM: bandwidth = 6 kHz, SINAD = 12 dB, fmod = 1 kHz, m = 0.5

≤ –101 dBm (≤ 2 µV)

FM: bandwidth = 15 kHz, SINAD = 20 dB, fmod = 1 kHz, deviation = 5 kHz

≤ –101 dBm (≤ 2 µV)

SSB: bandwidth = 2.4 kHz, SINAD = 12 dB, ∆f = 1 kHz

≤ –107 dBm (≤ 1 µV)

3.6 GHz to 6 GHz

CW: bandwidth = 600 Hz, SINAD = 12 dB

≤ –113 dBm (≤ 0.5 µV)

Demodulation all IF bandwidths AM, FM, PM, PULSE, I/Q IF bandwidths ≤ 9 kHz LSB, USB, CW

Demodulation modes

IF bandwidths ≥ 1 kHz ISB Squelch (squelch level) in 1 dB steps –30 dBμV to +120 dBμV

AGC, MGC, 130 dB AGC mode FAST/DEFAULT/SLOW

Gain control

MGC settable in 1 dB steps Automatic frequency control (AFC) automatic retuning for frequency-unstable

signals ± ½ IF bandwidth (100 Hz to 5 MHz)

Audio filter notch/noise reduction/bandpass

IF bandwidth Bandwidth demodulation, level and offset

measurement (3 dB bandwidth), 29 filters

100/150/300/600 Hz, 1/1.5/2.1/2.4/2.7/3.1/4/4.8/6/9/12/15/30/50/120/150/250/300/500/800 kHz, 1/1.25/1.5/2/5 MHz

3 dB:60 dB ≤ 1:1.7 for filter up to 2 MHz Shape factor 3 dB:50 dB ≤ 1:1.6 for 5 MHz filter

ADC resolution Resolution of A/D converter 16 bit

Page 6: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

6 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Level and offset measurement Signal level –30 dBμV to 120 dBμV,

resolution 0.1 dB Indication error max. ±3 dB, ±1 dB (typ.) Level detector AVG, PEAK, FAST, RMS Measurement modes Continuous, Periodic Measurement time 0.5 ms to 900 s or automatic Frequency offset up to ± ½ IF bandwidth (100 Hz to 5 MHz),

resolution 1 Hz

IF panorama up to 4096-point FFT dynamic, overlapping FFT

automatic or variable with selectable frequency resolution

FFT IF panorama operating mode

0.625/1.25/2.5/3.125/6.25/12.5/25/31.25/ 50/62.5/100/125/200/250/312.5/500/ 625 Hz, 1/1.25/2/2.5/3.125/5/6.25/8.333/10/12.5/ 20/25/50/100/200/500 kHz, 1 MHz, 2 MHz

IF panorama span 1/2/5/10/20/50/100/200/500 kHz, 1/2/5/10/20 MHz

Panorama display ClearWrite, Average, MaxHold, MinHold

Modulation measurement (with R&S®EB500-IM option) AM (modulation index) AM, AM+, AM–,

m = 0 % to 999.9 %, resolution 0.1 %, fmax = 2.5 MHz

Indication error < 5 % for bandwidth ≤ 1 MHz, < 7 % for bandwidth > 1 MHz (S/N > 40 dB, AF = 1 kHz, measurement time < 1 s)

FM (FM deviation) FM, FM+, FM–, ∆f = 0 Hz to 2.5 MHz, resolution 1 Hz, fmax = 2.5 MHz (fmod + deviation)

Indication error < 2 % of IF bandwidth used (absolute) (S/N > 40 dB, AF = 1 kHz, measurement time < 1 s)

φM ∆φ = 0 rad to 12.5 rad, resolution 0.01 rad, fmax = 2.5 MHz (fmod + deviation)

Indication error < (0.1 rad + 3 % of display) (S/N > 40 dB, AF = 1 kHz, measurement time < 1 s)

Bandwidth measurement automatic up to 20 MHz bandwidth, x dB and ß% method

Scan characteristics 10000 programmable memory locations Memory scan speed up to 500 channel/s user-selectable start/stop frequency and

step width Frequency scan

speed up to 500 channel/s with R&S®EB500-PS option RF spectrum with user-selectable

start/stop frequency and step width: 100/125/200/250/500/625 Hz, 1/1.25/2/2.5/3.125/5/6.25/8.333/10/12.5/ 20/25/50/100/200/500 kHz, 1 MHz, 2 MHz

Panorama scan

speed up to 12 GHz/s

Page 7: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

Rohde & Schwarz R&S®EB500 Monitoring Receiver 7

Antenna input HF 1 input, N female, 50 Ω Antenna input HF/VHF/UHF combined 1 input, N female, 50 Ω 9 kHz to 3.6 GHz ≤ 2 VSWR 3.6 GHz to 6 GHz ≤ 2.5

Input level –137 dBm to +10 dBm Max. input level (non-destructive) +15 dBm Oscillator reradiation at antenna input ≤ –90 dBm, –100 dBm (typ.)

9 kHz to 400 kHz lowpass filter 400 kHz to 32 MHz highpass/lowpass filter, switchable 20 MHz to 1.5 GHz tracking preselection 1.5 GHz to 6 GHz bandpass filter

manual or automatic 25 dB in 5 dB steps from 400 kHz to 32 MHz (HF tuner)

Input selection

switchable attenuation

40 dB in 1 dB steps from 20 MHz to 6 GHz (VHF/UHF tuner)

Input and output Input

External reference 10 MHz input level: 0 dBm to 10 dBm Control signals serial, GPS/compass, trigger, blank

Output Internal reference 10 MHz output level: 3 dBm to 7 dBm Video A, video B analog video, AM (A) and FM (B),

DC to ½ IF bandwidth or analog IF, controlled, 2 channels, adjustable center frequency 0 Hz to 70 MHz, bandwidth equal to IF filter width, level ≥ –11 dBm

Digital video LAN, bandwidth ≤ 5 MHz Digital I/Q LAN, bandwidth ≤ 5 MHz

headphone connector 0 V to ≥ 2 V, Ri = 100 Ω, fmin = 10 Hz to 300 Hz, fmax = 12.5 kHz (depending on IF filter and modulation)

AF line 0.5 V ± 0.2 V (m = 0.5), Ri = 100 Ω, fmin = 10 Hz to 300 Hz, fmax = 12.5 kHz (depending on IF filter and modulation)

Analog audio

AF balance 0.4 V ± 0.2 V (m = 0.5), Ri = 600 Ω, fmin = 100 Hz, fmax = 12.5 kHz

Control signals signal > squelch threshold, COR, antenna control

LAN for data transfer and remote control 1 Gbit LAN interface (Ethernet 10/100/1000BaseT)

USB for external storage 1 USB port (model .03 only)

Page 8: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

8 Rohde & Schwarz R&S®EB500 Monitoring Receiver

General data Environmental data

Climatic conditions in line with EN 60068-2-1, EN 60068-2-2 Operating temperature range 0 °C to +50 °C

model .02 –10 °C to + 55 °C Permissible temperature range model .03 0 °C to +55 °C model .02 –40 °C to +70 °C model .03 –30 °C to +70 °C

Storage temperature range

with AC/DC adapter –20 °C to +70 °C model .02 max. 95 %, +25 °C/+55 °C Humidity (non-condensing) model .03 max. 80 %, +25 °C/+40 °C

Environmental tests Shock in line with EN 60068-2-27,

MIL-STD-810E, method 516.4, procedure I sinusoidal 5 Hz to 150 Hz, in line with EN 60068-2-6 Vibration random 10 Hz to 500 Hz,

in line with EN 60068-2-64 Electromagnetic compatibility (EMC) in line with EN 300339,

ETSI EN 301489-1, ETSI EN 301489-22 model .02 > 35000 h MTBF (IEC 1709) model .03 > 17000 h AC 100 V to 240 V

50 Hz to 60 Hz, via external AC/DC supply

Power supply

DC 10 V to 32 V, 12 A to 4 A (depending on options installed)

Mechanical data Dimensions W × H × D 213 mm × 132 mm × 450 mm

(8.39 in × 5.20 in × 17.712 in), ½ 19", 3 HU

Weight approx. 7.5 kg (16.53 lb) (depending on options installed)

Page 9: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

Rohde & Schwarz R&S®EB500 Monitoring Receiver 9

Ordering information Designation Type, description Order No. Monitoring Receiver, with control front panel

R&S®EB500 4072.5004.03

frequency range from 20 MHz to 3.6 GHz, IF spectrum (max. 20 MHz), remote control software supplied with receiver

Monitoring Receiver, without control front panel

R&S®EB500 4072.5004.02

frequency range from 20 MHz to 3.6 GHz, IF spectrum (max. 20 MHz), remote control software supplied with receiver

Hardware options HF Frequency Range Extension R&S®EB500-HF 4072.8003.02 frequency range from 9 kHz to 32 MHz Software options SHF Frequency Range Extension R&S®EB500-FE 4072.9300.02 frequency range from 3.6 GHz to 6 GHz Panorama Scan R&S®EB500-PS 4072.9200.02 RF scan, high-speed FFT scan across user-selectable

range, selectable spectral resolution

ITU Measurement Option R&S®EB500-IM 4072.9100.02 ITU-compliant measurement of AM/FM-modulated

signals in the R&S®EB500

Software Package in line with ITU-R SM.1600 (PC-based Software for ITU-compliant measurement of signals with analog or digital modulation)

R&S®GX430IS 4071.5817.02

Accessories 19" Rack Adapter R&S®ZZA-T04 1109.4187.00 for mounting two R&S®EB500 in a 19" rack

(both receivers side by side)

19" Rack Adapter R&S®ZZA-T02 1109.4164.00 for mounting one R&S®EB500 in a 19” rack

(including one blind plate)

Service options Two-Year Calibration Service R&S®CO2EB500 Three-Year Calibration Service R&S®CO3EB500 Five-Year Calibration Service R&S®CO5EB500 One-Year Repair Service following the warranty period R&S®RO2EB500 Two-Year Repair Service following the warranty period R&S®RO3EB500 Four-Year Repair Service following the warranty period R&S®RO5EB500

Please contact your local Rohde & Schwarz sales office.

For product brochure, see PD 5214.3800.12 and www.rohde-schwarz.com.

Page 10: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

10 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Page 11: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

Version 01.02, February 2011

Rohde & Schwarz R&S®EB500 Monitoring Receiver 11

Page 12: R&S®EB500 Radiolocation Data Sheet | 01.02 Monitoring ...telekomunikacije.etf.rs/predmeti/ot3tm2/nastava/...Version 01.02, February 2011 4 Rohde & Schwarz R&S®EB500 Monitoring Receiver

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG

Trade names are trademarks of the owners | Printed in Germany (sk)

PD 5214.3800.22 | Version 01.02 | February 2011 | R&S®EB500

Subject to change

© 2010 - 2011 Rohde & Schwarz GmbH & Co. KG | 81671 München, Germany

About Rohde & SchwarzRohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solu-tions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established more than 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquar-ters are in Munich, Germany.

Environmental commitment Energy-efficient products Continuous improvement in environmental sustainability ISO 14001-certified environmental management system

Rohde & Schwarz GmbH & Co. KGwww.rohde-schwarz.com

Regional contactEurope, Africa, Middle East +49 89 4129 123 45 [email protected] America 1 888 TEST RSA (1 888 837 87 72) [email protected] America +1 410 910 79 88 [email protected]/Pacific +65 65 13 04 88 [email protected]

Certified Quality System

ISO 9001

Service you can rely onJ Worldwide J Local and personalizedJ Customized and flexibleJ Uncompromising qualityJ Long-term dependability

5214380022