•Warninglinesystemprovidingquickset-upandremoval.•30lb.RecycledRubberBaseweightstaysinplace.Won’tdamagetheroof.•DurableLowDensityPlasticDelineatorConesstackwithorwithoutbase.•Basedropsoverconeforeasyset-up,basesstackforeasytransport&storage.•MeetsOSHARegulation16lb.pulltest.•AvailablewithorwithoutReflectiveSheeting.•AnotherhighqualityproductfromTrafFixDevices,Inc.
47039-CRU-30 CompleteUnit,Cone&Base
OSHA1926.502 Compliance
Roof Edge Delineator Cone for Roof Warning Line SystemsDESIGNEDTOMEETOSHA1926.502
(39”OSHAMaximumTie-OffHeight)
™
160 Avenida La Pata, San Clemente, CA 92673(949) 361-5663 FAX (949) 361-9205
www.traffixdevices.com
Distributed by:
RoofEdgeDelineator™
PB112116
Drop over base for easy set-up
OSHA RegulationsStandard #:1926.502(f) Warning Line Systems
1926.502(f)(2)Warninglinesshallconsistofropes,wires,orchains,andsupportingstanchionserectedasfollows: OSHA Recommedation: A warning line is used 6-15 feet from the edge of the roof, dependaing on the slope. The warning line meets or exceeds the requirements in 1926.502(f)(2).
1926.502(f)(2)(i)Therope,wire,orchainshallbeflaggedatnotmorethan6-foot(1.8m)intervalswithhigh-visibilitymaterial; ManufacturersRecommendation:Spacingbetweentheroofedgedelineatorstobe6’-10’.
1926.502(f)(2)(ii)The rope, wire, or chain shall be rigged and supported in such a way that its lowest point (including sag) is no less than 34 inches (.9 m) from the walking/working surface and its highest point is no more than 39 inches (1.0 m) from the walking/working surface;
1926.502(f)(2)(iii)Afterbeingerected,withtherope,wire,orchainattached,stanchionsshallbecapableofresisting,withouttippingover,aforceofatleast16pounds(71N)appliedhorizontallyagainstthestanchion,30inches(.8m)abovethewalking/workingsurface,perpendiculartothewarningline,andinthedirectionofthefloor,roof,orplatformedge;
1926.502(f)(2)(iv)Therope,wire,orchainshallhaveaminimumtensilestrengthof500pounds(2.22kN),andafterbeingattachedtothestanchions,shallbecapableofsupporting,withoutbreaking,theloadsappliedtothestanchionsasprescribedinparagraph(f)(2)(iii)ofthissection;and
1926.502(f)(2)(v)Thelineshallbeattachedateachstanchioninsuchawaythatpullingononesectionofthelinebetweenstanchionswillnotresultinslackbeingtakenupinadjacentsectionsbeforethestanchiontipsover.
1926.502(f)(3)Noemployeeshallbeallowedintheareabetweenaroofedgeandawarninglineunlesstheemployeeisperformingroofingworkinthatarea.
1926.502(f)(4)Mechanicalequipmentonroofsshallbeusedorstoredonlyinareaswhereemployeesareprotectedbyawarninglinesystem,guardrailsystem,orpersonalfallarrestsystem.
™