RMS alarm under IHA decontamination
description
Transcript of RMS alarm under IHA decontamination
![Page 1: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/1.jpg)
RMS alarm under IHA decontamination
RMS alarm under IHA decontamination
2012. 9. 25
Shin-Kori Nuclear Power Plant
Korea Hydro & Nuclear Power
![Page 2: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/2.jpg)
INTRODUCTIONINTRODUCTION
During the Operation, Occurring the RadiationParticle
Appropriate Protection
Dose reduction
Protection from Internal Exposure
As Low As Resonably Achievable
![Page 3: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/3.jpg)
Title : IHA Cleaning operation
Period : 2012. 1. 26 ~ 2012. 1. 28
Purpose : Removal of the foreign substance attached to IHA
Operation personnel : 12person
INTRODUCTIONINTRODUCTION
![Page 4: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/4.jpg)
WORK PLACEWORK PLACE
refueling pool arearefueling pool area
S/G cavity BS/G cavity B
S/G cavity AS/G cavity A
UCSA & upper Air Plenum AreaUCSA & upper Air Plenum Area
P/HP/H
E/HE/H
IHA storage AreaIHA storage Area
![Page 5: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/5.jpg)
Dry Ice Cleaning TheoryDry Ice Cleaning Theory
![Page 6: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/6.jpg)
1. Sublimate Material
2. Carbon Dioxide Created by Compressing and Cooling
3. Liquefied At a Low Temperature
4. Sublimation as to supply heat to the surround and foreign objects fall as expended
Dry Ice FeaturesDry Ice Features
![Page 7: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/7.jpg)
Work ProcedureWork Procedure
1. Spray DryIce on the IHA
2. The operator wears a mask
3. Work environment Spatial Dose = 5μSv/hr, No airborne particle
4. Work with the Radiation Safety Manager
![Page 8: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/8.jpg)
Attached Boric acid Attached Boric acid
![Page 9: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/9.jpg)
Cleaning of Boric acidCleaning of Boric acid
![Page 10: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/10.jpg)
LCSA CleaningLCSA Cleaning
Cleaning internal IHACleaning internal IHA
![Page 11: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/11.jpg)
Radiation Monitor AlarmRadiation Monitor Alarm
During the Dryice spray, Alarm occurs in the Radiation Monitoring System(RMS)
The alarm Caused by Radioactive particle
Workers complete the decontamination, and leave the workplace
Airsampling is Performed, Checking Exposure
Radioactive Particles blow into the air with the dryice
![Page 12: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/12.jpg)
RMS Alert / HighRMS Alert / High
![Page 13: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/13.jpg)
RMS Line DrawingRMS Line Drawing
![Page 14: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/14.jpg)
PrecautionPrecaution
![Page 15: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/15.jpg)
PrecautionPrecaution
1. Tent is installed in the workspace
2. Workers are wearing a mask
3. Discharged to the outside from inside the tent through the air ventillation
4. More Clothes on the outside, In order to prevent additional contamination
![Page 16: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/16.jpg)
ResultsResults
1. Workers are not internal Exposure
2. Total External Dose = 0.9man-mSv(total : 10person) This Dose is due to the spatial dose
3. IHA thoroughly cleaned
4. Radiation Monitoring System was normal operation
![Page 17: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/17.jpg)
Comparison on decontamination Comparison on decontamination Before work / After workBefore work / After work
![Page 18: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/18.jpg)
ConclusionConclusion
1. Radioactive Particle Floats in the Air. It causes Internal exposure.
2. Maybe necessary Paricles occuring in the workplace should not be entered into the human body
3. IMA cleaning need something like the size of the tent because of the size and installed to perform the operation.
![Page 19: RMS alarm under IHA decontamination](https://reader036.fdocuments.us/reader036/viewer/2022062409/568148b2550346895db5c79e/html5/thumbnails/19.jpg)