Rig Engineering Case Study 2108 R...

1
R.E. scope of work was preparing stress analysis of hull structure for survival storm condition and compare results between as-built plate thicknesses and wasted plate thicknesses (15 % less). The main plating (main deck, bottom deck, side shell, internal BHD, stiffeners and beams) was also checked per applicable ABS minimum scantling requirements. Engagement Condition Upload your problem to us and give us relevant input to allow us to resolve your problem, we will need: 1. As built of structure to create 3D FEA model. 2. Static and environmental loads. 3. Wasted area of structural elements. Rig Name: Harvey H. Ward Rig Type: Jack -up Owner name: Transocean Classification Society: ABS Pertinent code: SNAME Code design: ASD Click below to see model 3D! Rig Engineering Case Study 2108 Harvey H. Ward Global Strength Analysis Get Adobe Reader To view 3D documents R RIG ENGINEERING E www.rig-engineering.com Tel. (+44) 1224 627200 Project description: Jack-up global strength analysis has been prepared to demonstrate that after accounting for wasted areas the jack-up hull is structurally adequate to withstand the maximum survival environmental criteria noted in the Operating Manual. FEA Model Stress Plot R Key word: Rig Engineering, Harvey H. Ward, Jack-up, wasted, FEA analysis. E © Copyrights by Rig-Engineering Rev. 0 Loads

Transcript of Rig Engineering Case Study 2108 R...

Page 1: Rig Engineering Case Study 2108 R Erig-engineering.info/wp-content/uploads/2014/05/Case_Study_2108_… · : Transocean Classification Society: ABS Pertinent code: SNAME Code design:

R Key word: Arctic III, New Lifeboat Installation, Global Assessment of Lifeboat Platform

E

R.E. scope of work

was preparing stress analysis of hull

structure for survival storm

condition and compare results

between as-built plate thicknesses

and wasted plate thicknesses (15 %

less).

The main plating (main deck, bottom

deck, side shell, internal BHD,

stiffeners and beams) was also

checked per applicable ABS

minimum scantling requirements.

Engagement Condition

Upload your problem to us and give

us relevant input to allow us to

resolve your problem, we will need:

1. As built of structure to create 3D

FEA model.

2. Static and environmental loads.

3. Wasted area of structural

elements.

Rig Name: Harvey H. Ward

Rig Type: Jack -up

Owner name: Transocean

Classification Society: ABS

Pertinent code: SNAME

Code design: ASD

Click below to see model 3D!

Rig Engineering Case Study 2108 Harvey H. Ward Global Strength Analysis

Get Adobe Reader To view 3D documents

R RIG ENGINEERING

E

www.rig-engineering.com

Tel. (+44) 1224 627200

Project description: Jack-up global strength analysis has been prepared to demonstrate that after accounting for

wasted areas the jack-up hull is structurally adequate to withstand the maximum survival environmental criteria

noted in the Operating Manual.

FEA Model

Stress Plot

R Key word: Rig Engineering, Harvey H. Ward, Jack-up, wasted, FEA analysis.

E

© Copyrights by Rig-Engineering Rev. 0