Review of tests of superconducting magnets in SM18 - Stephane Sanfilippo AT-MTM-AS Field Quality of...
-
Upload
brook-norris -
Category
Documents
-
view
212 -
download
0
Transcript of Review of tests of superconducting magnets in SM18 - Stephane Sanfilippo AT-MTM-AS Field Quality of...
Review of tests of superconducting magnets in SM18 - Stephane Sanfilippo AT-MTM-AS
Field Quality of MQ.
Measured in SM18
Presented by: Stephane Sanfilippo
AT-MTM-AS
Review of tests of superconducting magnets in SM18 - Stephane Sanfilippo AT-MTM-AS
What we measured so far. 49 arc SSS tested at cold. Field strength :48 MQ measured :
7 MQ measured with the scanner (rotating coils). 40 MQ measured with the SSW system. Analysis performed on 21 MQ.
Field Quality (multipoles) :16 MQ’s magnets cold tested in the SSS. 15 X-section 1+1 X-section 2
Review of tests of superconducting magnets in SM18 - Stephane Sanfilippo AT-MTM-AS
Warm/cold correlation status (MQ).
Offset of~17 units between the two systems.scanner not properly calibrated ?
MQ 120 (X section-2) out of the correlation.
W/C correlation for strength not validated for the MQ.Standard measurements (shaft + SSW) have to be maintained for MQ ‘s in the SSS until
validation.
w/c~5 units (SSW)
w/c~3 units (scanner)
(established at nominal current)
58.1
58.2
58.3
58.4
58.5
58 58.1 58.2 58.3 58.4
warm TF (T / kA)
cold
TF
(T
/ kA
)
SSW
17 units
MQ66?
MQ60?
MQ120?
MQ56?
Scanner (rotating coil)
45 units
Review of tests of superconducting magnets in SM18 - Stephane Sanfilippo AT-MTM-AS
Warm/cold correlation status (MQ).
-5
0
5
10
-5 0 5 10
warm b6- units @ 17 mm
cold
b6 (
unit
s @
17 m
m)
injectionnominal
MQ 120
MQ 120 (X section-2) out of the correlation.+2.3 units of difference.
Nominal : Offset of -0.34 units. w/c~0.22 unitsInjection : Offset of -3.8 units. w/c~0.33 units
-1
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
1
-1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1
warm b4- units @ 17 mm
cold
b4
(unit
s @
17
mm
)
injection
Offset of -0.3 units. w/c~0.36 units
b6 b4