Resolution Assessment in CryoEM

20
Resolution Assessment in CryoEM Kristin Shingler Friday, August 2 nd , 2013

description

Resolution Assessment in CryoEM. Kristin Shingler Friday, August 2 nd , 2013. What is Resolution?. In short, how close two objects can be without appearing as one. Atomic resolution is achieved in x-ray crystallography. - PowerPoint PPT Presentation

Transcript of Resolution Assessment in CryoEM

Page 1: Resolution Assessment in  CryoEM

Resolution Assessment in CryoEM

Kristin ShinglerFriday, August 2nd, 2013

Page 2: Resolution Assessment in  CryoEM

What is Resolution?• In short, how close two objects can be without

appearing as one.• Atomic resolution is achieved in x-ray

crystallography.• Typically, cryoEM generates sub-nanometer

resolution, but recent reconstructions have approached atomic resolution.

Page 3: Resolution Assessment in  CryoEM

Semliki Forest Virus 1986

3.2 nanometer resolution Vogel et al., 1986 Nature

Page 4: Resolution Assessment in  CryoEM

Sub-nanometer Resolution

Hepatitis B Capsid, 9.1Å Resolution Conway et al., 1997 Science

Page 5: Resolution Assessment in  CryoEM

Near-Atomic Resolution

Epsilon 15 Bacteriophage, 4.5Å Resolution Jiang et al., 2008 Nature

Page 6: Resolution Assessment in  CryoEM

Atomic Resolution

Human Adenovirus 5, 3.6Å Resolution Liu et al., 2010 Science

Page 7: Resolution Assessment in  CryoEM

What does resolution really mean?

Zhou, Current Opinions in Structural Biology, 2008

Page 8: Resolution Assessment in  CryoEM

What does resolution really mean?

Baker et al., Methods in Enzymology, 2010

Page 9: Resolution Assessment in  CryoEM

Resolution Assessment in X-ray Crystallography

Modified Figure 5 from Wlodawer et al. 2007

• Determined by how closely the crystal lattice can be packed, while still maintaining diffraction

• Various statistical measurements correlate the resolution

Page 10: Resolution Assessment in  CryoEM

3D Reconstruction Work Flow

Baker, Olson, and Fuller 1999 Microbiology and Molecular Biology Reviews

Page 11: Resolution Assessment in  CryoEM

Fourier Shell Correlation

F1 – Structure Factor for Map #1F2 – Structure Factor for Map #2ri – individual voxel elementr – radius

“measures the normliazed cross-correlation coefficient between two 3D volumes as a function of spatial frequency” - van Heel

Page 12: Resolution Assessment in  CryoEM

Conventional Resolution Estimation versus Gold Standard

Conventional Gold Standard

Model

EvenMap

OddMap

FSC and Resolution Estimate

Model Model

½DataMap

½DataMap

FSC and Resolution Estimate

Page 13: Resolution Assessment in  CryoEM

Conventional Resolution Estimation versus Gold Standard

Scheres and Chene, 2012 Nature Methods

Page 14: Resolution Assessment in  CryoEM
Page 15: Resolution Assessment in  CryoEM

Why this paper?

• Elife is an open access journal• It provides readers with both the reviewers

comments AND the author’s response to reviewers

• An excellent example of high quality work showing the disparity between conventional and gold standard resolution assessment

Page 16: Resolution Assessment in  CryoEM

Timeline of Events

• The authors first reported the resolution of their map to be 4.6Å by using conventional resolution assessment

• This method was challenged by reviewers • The authors reassessed resolution using the

gold standard method and found the map was 5.3Å resolution

Page 17: Resolution Assessment in  CryoEM

Reviewers Comment

Sun et al.,2013 Elife

Page 18: Resolution Assessment in  CryoEM

Author’s Response

Sun et al.,2013 Elife

Page 19: Resolution Assessment in  CryoEM

Chikungunya Virus Structure

Sun et al.,2013 Elife

Page 20: Resolution Assessment in  CryoEM

CryoEM Density Fitting

Sun et al.,2013 Elife