RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor...
Transcript of RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor...
![Page 1: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/1.jpg)
RESIDENTIAL SYSTEM SOLUTIONS
Ventergy® IAQ-BVSBlending/Filtering Ventilator Kits
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2014 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
VZ IAQ-BVS Kits_spec_1114
In order to meet ASHRAE 62.2 requirements, each BVS kit includes filters and Constant Airflow Regulators (CAR-II). The CAR-II accurately balances the amount of fresh air brought into the house. The fresh air is then mixed and filtered with the tempered air and distributed throughout the house. Blending/Filtering Ventilators are suitable for ALL ASHRAE Climatic Zones. In extreme weather conditions, the ratio of inside air can be increased to offset temperature differences. Kits include an ENERGY STAR certified BVS120 or 200 fan.
Ventergy® IAQ-BVS – Blending/Filtering Ventilator Kits*
Number of Bedrooms
House/Apt Square Feet
CFM Per ASHRAE
62.2
Kit(Components listed in table below)
Part Number
1<1500 30
IAQ-BVS120/514 25 7141501+ 45
2<1500 45
IAQ-BVS120/524 25 7241501-3000 60
3
<1500 45IAQ-BVS200/534-3 25 734
1501-3001 60
3001-4500 75 IAQ-BVS200/534-3MAX 25 735
4
1501-3000 75
IAQ-BVS200/534-4 25 7443001-4500 90
4501-6000 105
5
1501-3000 75
IAQ-BVS200/534-5 25 7543001-4500 90
4501-6000 105
Extra Filters (sold separately)Part Number Description
24 91812 Pack of Replacement Pleated Filters 12” x 12” x 1” (1 filter included with BVS Kit)
24 919Optional Electrostatic Permanent Filter 12” x 12” x 1” (Each)
* Galvanized steel standard. Contact American ALDES to request copper or stainless steel.
BVS Kit Components
KitPart
NumberKit Fan
Model
CAR-II (CFM) Supply Air Return Air Intake
5” 4” 4” 4” 6” Algrille
6” Universal
Sleeve
6” Backdraft Damper
6 x 6 x 6 Wye
4” Deco Grille
4” Sleeve with
Backdraft Damper
4 x 4 x 4 Wye
5” Wall Hood*
25 714 IAQ-BVS-120/514 BVS120 35/45/50 35/45/50 -- -- 1 1 1 -- 1 1 -- 1
25 724 IAQ-BVS-120/524 BVS120 35/45/50 35/45/50 35/45/50 -- 1 1 1 -- 2 2 -- 1
25 734 IAQ-BVS-200/534-3 BVS200 40/50/60 35/45/50 35/45/50 35/45/50 2 2 2 1 3 3 -- 1
25 735 IAQ-BVS-200/534-3MAX BVS200 75/90/105 35/45/50 35/45/50 40/50/60 2 2 2 1 3 3 -- 1
25 744 IAQ-BVS-200/534-4 BVS200 75/90/105 10/20/30 10/20/30 40/50/60 2 2 2 1 4 4 1 1
25 754 IAQ-BVS-200/534-5 BVS200 75/90/105 10/20/30 40/50/60 40/50/60 2 2 2 1 5 5 2 1
*Other kits available. Contact American ALDES for additional options.
![Page 2: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/2.jpg)
VENTERGY® SERIES FANSVentergy® Series Ventilator Fans represent years of engineering development to combine the energy efficiency and sound performance of a forward-curved fan with the durability and pressure characteristics of a backward-inclined impeller fan.
GENERALBVS Series Blending Ventilators are highly versatile, continuous-duty rated units for residential applications. They meet ENERGY STAR efficiency criteria for low energy consumption. The BVS is designed to provide fresh outdoor air and blend it with indoor air drawn from bedrooms or areas typically not served by a central thermostat before filtering and distributing this air to the main living areas of the home. Thermal comfort is enhanced because warmer air is drawn naturally from the heated living areas to the cooler bedrooms.
The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of unwanted infiltration through leaks in the building’s envelope. By slightly pressurizing the structure, the BVS also reduces the risk of backdrafting heating appliances, water heaters, and fireplaces. Quiet, continuous-duty, energy-efficient, external-rotor motors with permanently sealed bearings provide many years of maintenance-free performance.
CONSTRUCTIONBVS series fans are constructed of heavy-gauge galvanized steel to prevent corrosion caused by moisture. The cabinet is internally lined with acoustic, closed-cell foam insulation that acts as a vapor barrier. This allows for installation directly above living spaces or in unheated plenum spaces without concern for noise or condensation. Duct connecting collars may be relocated on the fan intake manifold to accommodate different installation requirements.
FAN AND MOTORThe fan motor is an energy-efficient, permanent-split-capacitor type of external-rotor design. Totally sealed to protect against moisture and contaminants, it incorporates permanently lubricated and sealed bearings and automatic-reset thermal-overload protection. It is designed and certified for continuous duty or intermittent operation.
The fan uses a backward-inclined impeller design that minimizes dust collection on blades. Each fan is statically and dynamically balanced at the factory to eliminate vibration and ensure quiet operation. The entire motor and fan assembly is mounted on a
VENTERGY® SERIES FANS
BVS120 & BVS200Blending/Filtering Ventilators
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
drop-down hinged access panel for simple service and inspection, and it can be removed from the fan without disassembling the duct connections.
FAN CONTROLSThe fan can be operated manually or automatically by a programmable timer, dehumidistat, or other appropriate electronic switch device. The fan may also be operated in conjunction with a variable speed control.
FILTERSEach BVS comes standard with a disposable-type pleated MERV 8 filter to comply with ASHRAE 62.2 and ENERGY STAR standards. Permanent, washable, electrostatic-type filters are also available.
LOCATING AND INSTALLING THE FANThe compact dimensions and versatile mounting options permit installation above drop ceilings, between ceiling joists, or within a small soffit location. They can be installed horizontally or vertically.
ACCESSORIESAccessories are available to accommodate applications ranging from single-bedroom apartments to five-bedroom houses. Accessories are included with the BVS only when ordered as a Ventergy® Series Continuous Duty IAQ Ventilation Kit.
AIRFLOW CONTROL OPTION AND BALANCING Each return and fresh air duct take-off can accommodate an automatic self-balancing constant airflow regulator (CAR-II) that ensures precise flow rates at each point, independent of duct lengths. A passive control element in each duct run inflates or deflates automatically in response to system pressure to maintain specified airflow rates.
PERFORMANCEFan airflow and energy performance shall be tested in accordance with HVI standards.
Internally insulated with acoustic vapor barrier insulation
Heavy-gauge G90 galvanized steel construction
AN-CELL™ pleated filter or A+2000 electrostatic permanent filter options
Drop-down hinged motor and filter access panels for easy service
High-efficiency motor meets ENERGY STAR performance criteria
BVS120 & BVS200 COMPONENTS
![Page 3: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/3.jpg)
BLENDING VENTILATOR FANAmerican ALDES Ventilation Corporation, Florida (1-800-255-7749). ALDES model BVS120 or BVS200.
GENERALThe fan shall be continuous-duty type with a backward-inclined centrifugal blower housed in a multi-port enclosure specifically designed for residential and commercial use. The fan shall be safety tested per UL standards and bear the agency listing certified mark, and be approved for use over cooking areas and tub/shower enclosures when used with GFCI branch circuiting. The fan must meet ENERGY STAR performance criteria for energy efficiency and bear the ENERGY STAR mark.
CONSTRUCTIONThe housing shall be of a minimum 22-gauge steel with a G90 galvanized coating or baked enamel paint finish. All interior surfaces of the housing shall be lined with a non-porous, closed-cell foam insulation to allow installation above ceilings and in unheated spaces without concern for condensation or absorption of water. The unit shall not exceed 8" in total height to allow mounting within ceiling/floor joist spaces. The blower shall be a centrifugal-type, external-rotor motor with backward-inclined impeller blades. The motor and blower assembly shall be mounted on a drop-down hinged access panel so as to permit removal from the housing without disassembly of the ducting connections. The filter must be accessible from a hinged drop-down access panel adjacent to the motor access. The intake duct connections shall be dimensioned so as to accept constant airflow regulators with a secure fit. The intake duct dimensions shall be nominal 4” and 5” round. The discharge duct dimension shall be nominal 6” round. The fan housing and intake duct collar(s) shall be designed to allow removal and repositioning in the field to accommodate different installation
WARRANTYThe entire unit is guaranteed for three (3) years, from date of shipment, against all manufacturing defects, provided the material has been installed and operated per manufacturer's instructions and under normal conditions. Warranty is limited to the repair or replacement of the
material upon its return freight paid to our factory. This warranty is not transferable and is limited to the original end user.
BVS120 & BVS200
2
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2014 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
BVS120 & BVS200_spec_1114
6 "
12 "
5 "
5 " 8 "
2-1/2"
1-7/8"
26-1/2"
5 "8 "
6 "
1 ¾"
4 "
4 "
4 "
TOP VIEW
SIDE VIEW
HINGED FILTER ACCESS
requirements. Mounting brackets shall be provided for attachment to the fan housing, allowing vertical or horizontal installations.
MOTOR The motor shall be direct-drive, external-rotor, high-efficiency, PSC type with permanently lubricated and sealed ball bearings and designed for continuous operation. The motor shall have automatic thermal-overload protection and must be totally sealed to protect against contaminants and moisture. Naturally vented air-over motors are not acceptable.
ELECTRICALThe fan shall operate on 115V, 50/60Hz, single-phase current. The motor shall be listed for use with a solid-state speed control.
FILTER The fan shall be provided with an approved 1” pleated panel type disposable filter meeting the ASHRAE standard MERV 8 rating. An optional permanent electrostatic filter shall be provided where specified. The filter shall be fully removable without the use of any tools and without disassembling internal partitions.
CONSTANT AIRFLOW REGULATORSWhen specified, each return air and fresh air intake collar shall accommodate an integral constant airflow control device that operates on duct system pressures and maintains specified airflow rates over a range of 0.2” to 0.8” Ps w.g. Devices shall be installed in the duct connections and calibrated at the factory to the airflow rates as indicated on the drawings. The device shall not exhaust any air to the outside during operation.
ELECTRICAL AND AIRFLOW PERFORMANCE*
Model Nominal RPM HP Watts at
0.2" Ps
CFM vs. Static Pressure
0" 0.2" 0.4" 0.6" 0.8"
BVS120 2146 0.06 43 186 152 122 94 67
BVS200 2960 0.08 66 261 236 210 186 162*Certified airflow rating at 0.2" w.g. is derated from actual test results per HVI Certification procedure 920.
NOTE: Dashed lines indicate alternate side collar location
ELECTRICAL DATA – BVS120 & BVS200120 V, 60 Hz., 0.35/0.53 Amp., 43/66 W Max.,
2146/2960 RPMAbove ratings are intended for sizing electrical wiring only.
Actual consumption will be lower.
6 "
12 "
5 "
5 " 8 "
2-1/2"
1-7/8"
26-1/2"
5 "8 "
6 "
1 ¾"
4 "
4 "
4 "
TOP VIEW
SIDE VIEW
HINGED FILTER ACCESS
Dimensions & Performance
Typical Specification
![Page 4: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/4.jpg)
GENERALThe model CAR-II Constant Airflow Regulator is a modulating orifice that automatically regulates airflows in duct systems to constant levels. The passive control element responds to duct pressure and requires no electric or pneumatic sensors or controls.
The CAR-II compensates for changes in duct pressure caused by thermal stack effect, building pressure, dust-clogged filters, etc. The CAR-II also provides a low-cost solution to balancing forced-air systems for heating, air conditioning and ventilation, eliminating the need for on-site balancing. The CAR-II will regulate airflow in supply, return, or exhaust duct systems.
The active control element of the CAR-II is a unique aerofoil. Using Bernoulli’s Principle, the aero-wing damper lifts in response to increasing static pressure. This operation regulates the free-area opening through the control, resulting in maintenance of velocity and specific airflow set points. Each CAR-II is designed and produced for control of air in temperatures ranging from -25°F to 140°F (-32°C to 60°C).
CONSTRUCTIONThe round CAR-II is constructed of a UL94V-0 ABS plastic, and it is UL 2043 safety classified and labeled for flame and smoke generation. The assembly is sized to fit inside standard rigid round ducting, as well as fittings such as take-offs, tees, etc. A lip or flex-type ring seal gasket around the circumference ensures a tight, no-leak fit.
AIRFLOW & ZONE CONTROLS
CAR-IIConstant Airflow Regulator
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
PERFORMANCEThe CAR-II airflow regulators control airflow accurately to within 10% of rated flow (15% for units 50 CFM or less) throughout the target operating pressure range of 0.2 to 0.8 in. w.g. (50 to 200 Pa). Each CAR-II is factory tested and calibrated to the rated set point before shipping. On-site field adjustment of airflow set points can be made for supply air applications (contact factory). Each diameter of CAR-II regulator is available in multiple factory-calibrated set points (see performance curves).
MAINTENANCEThe CAR-II needs no maintenance when used in normal conditions. There is no risk of dust deposit or obstruction because the CAR-II has no airways subject to clogging. If the intended application includes air heavily loaded with grease or dust, a fitting with an access panel or door, such as that used for flame dampers, should be provided.
WARRANTYGuaranteed for 5 years, from date of shipment, against all defects in material or workmanship, provided that the material has been installed and used under normal conditions. This warranty is limited to the repair or replacement of the material.
CAR-II Dimensions
DUCT CAR-II A B C
4” 4” 3.8” 4.1” 2.3”
5” 5” 4.8” 5.1” 3.5”
6” 6” 5.8” 6.1” 3.5”
8” 8” 7.6” 8.1” 3.5”
10” 10” 9.7” 10.1” 3.7”
SIDE FRONT
![Page 5: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/5.jpg)
Constant airflow is achieved by controlling the free area through the device. At minimum static pressure, the aero-wing is parallel to the air stream. As the static pressure increases, the aero-wing lifts, reducing the amount of free area through the regulator. At the same time, higher static pressure increases the air velocity resulting in CONSTANT AIRFLOW. This occurs regardless of pressure differences in the range of 0.2 to 0.8 in. w.g. (50 to 200 Pa). The air velocity in the duct is in the range of 60 to 700 ft/min. (0.3 to 3.5 m/s).
How the CAR-II Works
(6” EXAMPLE SHOWN)
CAR-II
2
Model CAR-II Constant Airflow Regulators by American ALDES Ventilation Corporation, Bradenton, Florida, shall solely operate on duct pressure and require no external power supply. Each regulator shall be pre-set and factory calibrated, requiring no field adjustment to the airflows as indicated on the schedule, and shall be rated for use in air temperatures ranging from -25° to 140°F (-32° to 60°C.)
Constant airflow regulators shall be capable of maintaining constant airflow within +/- 10% of scheduled flow rates (15% for units 50 CFM or less), within the operating range of 0.2 to 0.8 in. w.g. differential pressure, or 0.6 to 2.4 in. w.g. on high-pressure models (CAR-II-HP), or 0.1 to 0.42 in. w.g. on low-pressure models (CAR-II-LP). Regulators shall be provided as an assembly consisting of a 94V-0 UL ABS plastic body housed within a round sleeve for mounting in round duct. Each round sleeve must be fitted with a lip gasket to ensure perimeter air tightness with the interior surface of the duct. All regulators must be classified per UL 2043 and carry the UL mark indicating compliance. All Constant Airflow Regulators will require no maintenance and must be warranted for a period of no less than five years. Constant Airflow Regulators shall be installed in tight ducting systems in accordance with all applicable codes and manufacturer’s instructions.
Typical Specification
• Supply and exhaust air in offices.
• Balancing exhaust and supply airflows in high-rise building duct risers.
• Bathroom exhaust in nursing homes, hotels, motels, dormitories, apartment buildings, offices, etc.
• Clean room air supply balancing for ceiling filter modules. Maintains constant airflow even as filter resistance increases.
• Regulation of make-up air.
• Controlling conditioned air to sealed crawlspaces.
Typical CAR-II Applications• Balancing supply airflow from packaged roof-top A/C
units.
• Balancing supply and exhaust of heat recovery ventilation systems.
• Regulating outdoor air injection from central supply fan into individual room fan coil units or heat pumps.
• Balancing airflows on series-fan-powered terminal unit systems.
• Supply air to sleeping quarters in military facilities, submarines, etc.
![Page 6: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/6.jpg)
Performance charts reflect airflow measurements taken at 68°F (20°C) at 1 atmosphere pressure. The CAR-II is designed for system pressures between 0.2 and 0.8 in. w.g. Models are also available for applications with system pressures between 0.1 and 0.42 in. w.g (CAR-II-LP) and above 0.8 in. w.g. (CAR-II-HP).
PRESSURE DIFFERENCE (PASCALS)0 25 50 75 100 125 150 175 200
70
60
50
40
30
20
10
0
AIR
FLO
W(C
FM)
PRESSURE DIFFERENCE (IN. W.G.)0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
AIR
FLO
W(M
3H)
00
AIR
FLO
W(L
/S)
520
1040
60
80
100
15
20
25
3060(100)
50(90)45(75)
35(60)30(50)25(45)
20(30)
10(15)
40(70)
4" DIAMETER (100 mm) REGULATING ELEMENT
PART NUMBER AIRFLOW
18 111 10 CFM (15 m3/h)
18 112 20 CFM (30 m3/h)
18 113 25 CFM (45 m3/h)
18 114 30 CFM (50 m3/h)
18 115 35 CFM (60 m3/h)
18 109 40 CFM (70 m3/h)
18 116 45 CFM (75 m3/h)
18 117 50 CFM (90 m3/h)
18 118 60 CFM (100 m3/h)
0AI
RFL
OW
(L
/S)
25
PRESSURE DIFFERENCE (IN. W.G.)
PRESSURE DIFFERENCE (PASCALS)20012550 10075 150
160
200
50
60
40
30
20
10
00
120
80
40
175
AIR
FLO
W
(M3H
)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
100
120
AIR
FLO
W
(CFM
)
80
60
40
20
0
105(180)
90(150)
75(125)
60(100)50(90)
35(60)
5" DIAMETER (125 mm) REGULATING ELEMENT
PART NUMBER AIRFLOW
18 121 35 CFM (60 m3/h)
18 122 50 CFM (90 m3/h)
18 123 60 CFM (100 m3/h)
18 124 75 CFM (125 m3/h)
18 125 90 CFM (150 m3/h)
18 126 105 CFM (180 m3/h)
CAR-II
3
CAR-II Airflow Performance Data
6" DIAMETER (150 mm) REGULATING ELEMENT
50 100750
160
AIR
FLO
W
(CFM
)
AIR
FLO
W
(L/S
)
AIR
FLO
W
(M3H
)
25PRESSURE DIFFERENCE (PASCALS)
200125 150
250
30080
90
70
60
50
40
30
0
200
150
100
0
175
140
120
100
60
80
0
PRESSURE DIFFERENCE (IN. W.G.)0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
180
200
75(125)
90(150)
105(180)
125(210)
140(240)
160(270)
175(300) PART NUMBER AIRFLOW
18 131 75 CFM (125 m3/h)
18 132 90 CFM (150 m3/h)
18 133 105 CFM (180 m3/h)
18 134 125 CFM (210 m3/h)
18 135 140 CFM (240 m3/h)
18 136 160 CFM (270 m3/h)
18 137 175 CFM (300 m3/h)
![Page 7: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/7.jpg)
AIR
FLO
W(L
/S)
AIR
FLO
W(M
3H) 450
500
120
140
100
80
60
0
400
300
350
250
200
PRESSURE DIFFERENCE (IN. W.G.)0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0 25 50PRESSURE DIFFERENCE (PASCALS)
200125100 150 17575
160
120
200
240
280
320
0
AIR
FLO
W(C
FM)
0
295(500)
265(450)
235(400)
205(350)
175(300)160(270)
140(240)125(210)
8" DIAMETER (200 mm) REGULATING ELEMENT
PART NUMBER AIRFLOW
18 141 125 CFM (210 m3/h)
18 142 140 CFM (240 m3/h)
18 143 160 CFM (270 m3/h)
18 144 175 CFM (300 m3/h)
18 145 205 CFM (350 m3/h)
18 146 235 CFM (400 m3/h)
18 147 265 CFM (450 m3/h)
18 148 295 CFM (500 m3/h)
AIR
FLO
W(L
/S)
AIR
FLO
W(M
3H)
PRESSURE DIFFERENCE (PASCALS)
700200
150
100400
500
600
300
200 50
100
0 0
.G.). W(INDIFFERENCESUREPRES0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
AIR
FLO
W(C
FM)
0
50
100
150
200
250
300
350
400
450 2001751501251007550250410(700)380(650)355(600)325(550)295(500)265(450)235(400)205(350)
10" DIAMETER (250 mm) REGULATING ELEMENT
PART NUMBER AIRFLOW
18 151 305 CFM (350 m3/h)
18 152 235 CFM (400 m3/h)
18 153 265 CFM (450 m3/h)
18 154 295 CFM (500 m3/h)
18 155 325 CFM (550 m3/h)
18 156 355 CFM (600 m3/h)
18 157 380 CFM (650 m3/h)
18 158 410 CFM (700 m3/h)
CAR-II
4
CAR-II Airflow Performance Data
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2013 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
CAR-II_spec_0913
Performance charts reflect airflow measurements taken at 68°F (20°C) at 1 atmosphere pressure. The CAR-II is designed for system pressures between 0.2 and 0.8 in. w.g. Models are also available for applications with system pressures between 0.1 and 0.42 in. w.g (CAR-II-LP) and above 0.8 in. w.g. (CAR-II-HP).
![Page 8: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/8.jpg)
ROOF CAPS, WALL HOODS, GRILLES & DUCT FITTINGS
AlgrillesSupply/Exhaust Grilles
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2013 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
Algrilles_spec_1013
ALGRILLES• Supply/Exhaust • Available in 3”, 4”, 5”, 6”, & 8”• Fully adjustable for variable airflow capacity• Rotating center-adjustment cone• Easy to install• Durable white plastic (polypropylene co-polymer with HB
UL rating)
HOW TO USE THE ALGRILLEThe center adjustment cone allows for variable ventilation capacity.
After installing your Algrille vents and connecting them to the ductwork from your ventilator, begin balancing the ventilation ports by increasing openings on the most distant Algrille until the flow is satisfactory throughout the building. Usually two rounds of balancing will provide the desired air distribution.
INSTALLATIONCompression-spring tab clips the Algrille into 4", 5", 6", or 8" round duct.
C
A
B
D
Dimensional DataP/N SIZE A B C D
40 103 3” 2-7/8” 1” 1” to 1-7/8” 4-5/8”
40 104 4" 3-1/4” 1” 1-7/8" to 3-1/4” 5-7/8”
40 105 5" 3-1/2” 1-1/4” 2" to 3-1/4” 6-1/4”
40 106 6" 4-11/16” 1” 1-3/4" to 3-1/4” 7-1/2”
40 108 8" 6 -3/4” 1-3/4” 2-1/2" to 3-3/4” 9-5/8”
PRES
SURE
DRO
P IN
CHES
W.C
.
ALGRILLE FLOW SPECIFICATIONS AND PERFORMANCE GRAPH FULLY OPEN
CFM
0.24
0.20
0.16
0.12
0.08
0.04
0.000 30 90 120 150 180 210 240 270 30060
4" 5"6"
8"
Foam for tight seal and sound attenuation.
![Page 9: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/9.jpg)
ROOF CAPS, WALL HOODS, GRILLES & DUCT FITTINGS
Universal SleevesFor Connecting Grilles to Flex Duct Work
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2013 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
Universal Sleeves_spec_1013
DIMENSIONAL DATA
PART NUMBER DESCRIPTION Dia. A B C Dia.
DDia.
EDia.
F G H
22 094 4” Dia. Sleeve 9” 5-1/2” 7” x 9” 5” 4-1/8” 4” 1/2” 1”
22 095 5” Dia. Sleeve 10” 5” 8” x 10” 5-3/4” 5-1/8” 4-15/16” 1/2” 1”
22 096 6” Dia. Sleeve 11” 5-1/2” 9” x 11” 7” 6” 5-7/8” 1/2” 1”
22 098 8” Dia. Sleeve 11” 7-1/4” 11” x 11” 9-1/8” 8-1/8” 8” 1/2” 1”
C
A
B
D
E
F
G H
![Page 10: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/10.jpg)
AIRFLOW & ZONE CONTROLS
Backdraft DampersSpring-Loaded Backdraft Dampers
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2013 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
BDD_spec_1013
DESCRIPTION• 20-gauge galvanized steel housing.• Aluminum spring-loaded butterfly
damper blades.• Damper seals against EDPM rubber gasket
in closed position for minimal leakage.• Gasket designed for use in temperatures
from -22°F to180°F.• Requires airflows of 0.04 to 0.08 in. w.g. to
begin to open.• May be installed in any position. The 14"
and 16" models require adjusting spring tension if used in vertical position, with airflow down.
• The entire assembly inserts into duct for simple installation.
• Exterior foam gaskets provide a tight seal against interior surface of duct.
NOTE: Not recommended for use with clothes dryer, unless proper provisions are made for regular cleaning. For this application, request P/N 99 504, 4" diameter cape backdraft damper.
NOTE: Position of post in sleeve and number of springs varies according to model.
4"- 8" MODELS STAMPED METAL SLEEVE / CENTER PIN DESIGN
10"- 16" MODELS ROLLED METAL SLEEVE / CENTER POST DESIGN
Center
C
(Center Post)
NOMINAL A B C
4" 1-3/4" 2" 3-3/4"5" 2" 2-1/2" 4-3/4"6" 2-1/2" 3" 5-3/4"7" 2-1/2" 3-1/4" 6-3/4"8" 2-3/4" 3-3/4" 7-9/16"
NOMINAL A B C
10" 4-3/4" 5-3/4" 9-3/4"12" 6-1/4" 6-3/4" 11-3/4"14" 6-1/4" 7-3/4" 13-3/4"16" 6-1/4" 10-3/4" 15-3/4"
PART NUMBER DIAMETER (NOMINAL)
99 023 4" (100 mm)
99 024 5" (125 mm)
99 025 6" (150 mm)
99 035 7" (175 mm)
99 026 8" (200 mm)
99 027 10" (250 mm)
99 028 12" (315 mm)
99 036 14" (355 mm)
99 037 16" (400 mm)
Airflow Performance
![Page 11: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/11.jpg)
ROOF CAPS, WALL HOODS, GRILLES & DUCT FITTINGS
Wyes4” - 10”
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2013 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
Wyes_spec_1013
DIMENSIONAL DATA
PART NUMBER DIA. A DIA. B DIA. C
93 081 4” 3” 3”
93 082 4” 4” 4”
93 087 5” 4” 4”
93 083 5” 5” 5”
93 086 6” 4” 4”
93 085 6” 5” 5”
93 084 6” 6” 6”
93 090 8” 8” 8”
93 091 8” 6” 6”
93 094 10” 10” 10”
93 095 10” 8” 8”
A
C B
![Page 12: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/12.jpg)
ROOF CAPS, WALL HOODS, GRILLES & DUCT FITTINGS
Deco GrillesWhite Plastic Grilles
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2014 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
Deco Grilles_spec_0614
DIMENSIONAL DATA
PART NUMBER SIZE DESCRIPTION A B C D E F
22 073 3" White Plastic ABS Grille 3" 4-3/4" 1/2" 5/8" 1-7/8” 4-3/4”
22 079 4" White Plastic ABS Grille 3-7/8" 5-3/4" 11/16" 1" 2-1/2” 6-1/4”
22 078 5" White Plastic ABS Grille 4-7/8" 6-1/2" 5/8" 1-1/4" 3-1/8” 7-3/4”
A
F
EC
D
B
A
F
EC
D
B
![Page 13: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/13.jpg)
ROOF CAPS, WALL HOODS, GRILLES & DUCT FITTINGS
Universal SleevesWith Gravity Backdraft Dampers
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2013 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
Universal Sleeve with BDD_spec_1013
DIMENSIONAL DATA
PART NUMBER DESCRIPTION Dia. A B C Dia.
DDia.
EDia.
F G H
22 194 4” Dia. Sleeve 9” 5-1/2” 7” x 9” 5” 4-1/8” 4” 1/2” 1”
22 195 5” Dia. Sleeve 10” 5” 8” x 10” 5-3/4” 5-1/8” 4-15/16” 1/2” 1”
22 196 6” Dia. Sleeve 11” 5-1/2” 9” x 11” 7” 6” 5-7/8” 1/2” 1”
C
A
B
D
E
F
G H
![Page 14: RESIDENTIAL SYSTEM SOLUTIONS Ventergy IAQ-BVS & … · The BVS is designed to filter both indoor and incoming fresh air and prevent the introduction of contaminants as a result of](https://reader034.fdocuments.us/reader034/viewer/2022050215/5f60e6311021853b503eabbe/html5/thumbnails/14.jpg)
ROOF CAPS, WALL HOODS, GRILLES & DUCT FITTINGS
High-Performance Wall HoodsWith Screens or Gravity Dampers
PRODUCT SPECIFICATIONS
& TECHNICAL DATA
DESCRIPTIONAmerican ALDES High-Performance Wall Hoods are designed for use in exhaust or supply ventilation systems and fresh air kits. They are engineered to accommodate high airflow pressure and velocities found in premium fan and dryer vent systems. Wall hoods are available as screened or dampered versions. Each wall hood is designed to maximize airflow and minimize noise.
CONSTRUCTIONWall Hoods are available in heavy-gauge G90 galvanized steel, 314 2B finish stainless steel, or solid copper type CA 110.
SCREENED WALL HOODS1/4” galvanized steel mesh. Suitable for use in exhaust or supply ventilation systems and fresh-air kits.
DAMPERED WALL HOODS For use in exhaust ventilation and dryer venting systems. A magnetic-catch damper ensures a tight closure when the fan is not running and eliminates damper flutter in windy conditions. These hoods should be used when backdraft dampers are not present at other locations within the duct system.
American ALDES Ventilation Corporation • 4521 19th Street Court East, Suite 104 • Bradenton, FL 34203 – USA941.351.3441 • 800.255.7749 • 941.351.3442 (fax) • [email protected] • www.aldes.us
© 2013 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice.
HP Wall Hoods_spec_1013
GALVANIZED STEEL
STAINLESS STEEL COPPER
MODELGalvanized** Stainless Steel Copper
DimensionsDampered* Screened Dampered* Screened Dampered* Screened
Size P/N P/N P/N P/N P/N P/N A B C D E F
4" 22 404 22 304 22 404SS 22 304SS 22 404COP 22 304COP 4” 3” 3.0” 4.5” 8” 6”5" 22 405 22 305 22 405SS 22 305SS 22 405COP 22 305COP 5” 3” 3.0” 5.0” 9” 8”6" 22 406 22 306 22 406SS 22 306SS 22 406COP 22 306COP 6” 3” 4.0” 6.0” 10” 9”8" 22 408 22 308 22 408SS 22 308SS 22 408COP 22 308COP 8” 3” 5.0” 8.0” 12” 11”
10" 22 410 22 310 22 410SS 22 310SS 22 410COP 22 310COP 10” 3” 6.5” 10.0” 14” 13”12" 22 412 22 312 22 412SS 22 312SS 22 412COP 22 312COP 12” 3” 8.5” 12.0” 16” 15”
*For wall hoods with screens and backdraft dampers, add backdraft damper to screen model. See Backdraft Damper spec sheet for backdraft damper part numbers.**Galvanized Steel Items (4” to 8” are 26 gauge; 10” and 12” are 24-gauge). Materials: Galvanized Steel G-90, Copper Type Ca110, Stainless Type 314-2B Finish SMACNA GAUGE ACCORDING TO SIZE. Damper: Aluminum sheet, 0.020”
Dimensional DataC
A E
B
D FWith Damper With Screen