Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available....
Transcript of Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available....
![Page 1: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/1.jpg)
![Page 2: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/2.jpg)
![Page 3: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/3.jpg)
![Page 4: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/4.jpg)
![Page 5: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/5.jpg)
![Page 6: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/6.jpg)
![Page 7: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/7.jpg)
VAN BOERUM
& FRANK ASSOCIATES, INC.
CONSULTING
ENGINEERS
W W W . V B F A . C O M
801.530.3148 T
801.530.3150 F
330 South 300 East
Salt Lake City, UT 84111
Salt Lake City ▪ Logan ▪ St. George ▪ Tempe
VBFA Project Number: 19104
LIC
ENSE
D P
ROFESS I ONAL ENGIN
EER
No. 187737
S TA T E O F U TAH
JEFFREY S.WATKINS
PLUMB. GENERAL NOTES
”
MECH. GENERAL NOTES
KEYED NOTES
#
GRILLES, REGISTERS AND DIFFUSERS
ID MANUFACTURER MODEL DESCRIPTION
MOUNTING-FRAME: SURFACE OR LAY-IN,
FACE STYLE: PERFORATED DIFFUSER
(C/W CEILING TYPE.)
FACE SIZE: 24" x 24", 24" x 12" OR 12" x 12" ASPATTERN: 4 WAY
CD-1 EH PRICE PDC REQUIRED TO FIT CEILING TILE SPACE AVAILABLE DAMPER: OPPOSED BLADE
APPLICATION: CONSTANT VOLUME MAX NC - 30
MATERIAL: STEEL REMOVABLE FACE & CORE
FINISH: B12 WHITE POWDERCOAT INDIVIDUALLY ADJUSTABLE CURVED BLADES
PROVIDE: ROUND NECK ADAPTER
FACE STYLE: PERFORATED RETURN AIR UNITMOUNTING-FRAME: SURFACE OR LAY-IN,
FACE SIZE: 24" x 24", 24" x 12" OR 12" x 12" AS
(C/W CEILING TYPE.)
RG-1 EH PRICE PDDR REQUIRED TO FIT CEILING TILE SPACE AVAILABLE. DAMPER: NONE
APPLICATION: AIR RETURN
MATERIAL: STEEL MAX NC - 30
FINISH: B12 WHITE POWDERCOAT REMOVABLE FACE & CORE
![Page 8: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/8.jpg)
NATIONAL ELEC. CODENEC
NEMA
NATIONAL FIRE CODENFC
NFPA
FMC FLEXIBLE METAL CONDUIT
FVNR
FULL VOLTAGE REVERSINGFVR
GROUNDG
GENERATORGEN
MOP
IN/IS
FULL LOAD AMPS
FIRE ALARM CONTROL PANELFACP
FLA
NC NORMALLY CLOSED
NA NOT APPLICABLE
PROTECTION
MOCP MAXIMUM OVER-CURRENT
MLO MAIN LUGS ONLY
MIN MINIMUM
MH MAN HOLE
MDP MAIN DISTRIBUTION PANEL
MCP MOTOR CIRCUIT PROTECTION
MCC MOTOR CONTROL CENTER
MCB MAIN CIRCUIT BREAKER
MCA MINIMUM CIRCUIT AMPS
MC METAL CLAD
MAX MAXIMUM
LV LOW VOLTAGE
LTG LIGHTING
LRC LOCKED ROTOR CURRENT
LPS LOW PRESSURE SODIUM
LFNC
LED LIGHT EMITTING DIODE
kWh KILOWATT HOUR
kW KILOWATT
kVAR KILOVOLT AMPERE REACTIVE
kVA KILOVOLT AMPERE
kV KILOVOLT
IR INFRARED
I/O INPUT/OUTPUT
INSULATED/ISOLATED
IMC
IG ISOLATED GROUND
Hz HERTZ
HV HIGH VOLTAGE
HPS HIGH PRESSURE SODIUM
HP HORSEPOWER
HOA HAND-OFF-AUTOMATIC
HID HIGH INTENSITY DISCHARGE
HD HEAVY DUTY
GFP GROUND FAULT PROTECTION
GFCI
FA
EXIST
EQUIPMENTEQUIP
ENT
EMT
EMERGENCYEM
EACHEA
DOUBLE POLE DOUBLE THROWDPDT
UNIT OF SOUND LEVELdB
COPPERCU
CURRENT TRANSFORMERCT
CONTROL PANELCP
CIRCUITCKT
CUSTOM FINISH AS SELECTED BY ARCHITECT
CFBA
CLOSED CIRCUIT TELEVISIONCCTV
CCBA
CIRCUIT BREAKERCB
COMMUNITY ANTENNA TELE.CATV
BUCK BOOSTBB
AMERICAN WIRE GAGEAWG
FOUR POLE DOUBLE THROW4PDT
ADJACENT
ADA
ADJ
THREE-CONDUCTOR
ATS
ASC
AR
ANN
AMP
AL
AIC
AFG
AFF
4PST
3PH
1PH
3/C
2/C
AUTOMATIC TRANSFER SWITCH
AMPS SHORT CIRCUIT
AS REQUIRED
ANNUNCIATOR
AMPERE
ALUMINUM
ABOVE FINISHED GRADE
ABOVE FINISHED FLOOR
FOUR POLE SINGLE THROW
THREE PHASE
SINGLE PHASE
TWO-CONDUCTOR
THREE POLE
TWO POLE
ONE POLE
2P
3P
1P
EMERGENCY BATTERY PACKBP
GROUNDGND
AMPEREA
C COUNTER TOP HIEGHT
CL CEILING
FVMH
CD CANDELA (LUMEN INTENSITY)
NOT IN CONTRACTNIC
TRANSFORMERXFMR
WATER PROOFWP
WITHOUTW/O
WITHW/
VARIABLE FREQUENCY DRIVEVFD
VOLT AMPEREVA
VOLTSV
UPS
UNDERGROUNDUGND
NIGHT LIGHTNL
NORMALLY OPENNO
NOT TO SCALENTS
ON CENTEROC
OVER CURRENT PROTECTIONOCP
TWISTED SHIELDED PAIRTSP
UF UNDER FLOOR
TYP TYPICAL
TVSS
TV TELEVISION (CABLE)
TTB TELEPHONE TERMINAL BOARD
TP TWISTED PAIR
SWGR SWITCH GEAR
SWBD SWITCH BOARD
ST SINGLE THROW
S/S START/STOP
SPST SINGLE POLE, SINGLE THROW
SPEC SPECIFICATIONS
SPDT SINGLE POLE DOUBLE THROW
SFBA
SF SQUARE FOOT (FEET)
SCBA
SCA SHORT CIRCUIT AMPS
RR REMOVE AND RELOCATE
RPM REVOLUTIONS PER MINUTE
RNC RIGID NONMETALLIC CONDUIT
REL RELOCATED FIXTURE / DEVICE
RCP REFLECTED CEILING PLAN
R REMOVE
QTY QUANTITY
PNL PANEL
PH PHASE
PF POWER FACTOR
PB PUSH BUTTON
OL OVERLOAD
OHD OVERHEAD DOOR
OF/OI
W WALL
RMC RIGID METAL CONDUIT
SPD SURGE PROTECTION DEVICE
CUSTOM COLOR AS SELECTED BY ARCHITECT
ELECTRICAL NONMETALIC CONDUIT
ELECTRICAL METALIC CONDUIT
EXISTING FIRE ALARM
FIELD VERIFY MOUNTING HEIGHT
NATIONAL FIRE PROTECTION ASSOCIATION
NATIONAL ELECTRIC MANUFACTURERS ASSOC.
UNINTERRUPTIBLE POWER SOURCE
TRANSIENT VOLTAGE SURGE SUPPRESSOR
AMERICANS WITH DISABILITIES ACT
AMPERE INTERRUPTING CAPACITY
FULL VOLTAGE NON-REVERSING
GROUND FAULT CIRCUIT INTERRUPTER
OWNER FURNISHED/ OWNER INSTALLED
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE NONMETALIC CONDUIT
STANDARD COLOR AS SELECTED BY ARCHITECT
STANDARD FINISH AS SELECTED BY ARCHITECT
ABBREVIATIONS
1. ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST ADOPTED NATIONAL ELECTRICAL CODE.
2. VERIFY ALL EQUIPMENT DIMENSIONS AND LOCATIONS BEFORE BEGINNING ROUGH-IN. CONSULT ALL APPLICABLE CONTRACT DRAWINGS AND SHOP DRAWINGS. INSURE CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT PER N.E.C. BEFORE ROUGH-IN.
3. NOTIFY ARCHITECT/ENGINEER AND GENERAL CONTRACTOR IMMEDIATELY UPON FINDING ANY DISCREPANCIES. ELECTRICAL, MECHANICAL, AND GENERAL CONTRACTORS SHALL VERIFY ALL ELECTRICAL LOADS, VOLTAGE, PHASE, CONNECTIONS REQUIREMENTS, ETC. OF EQUIPMENT REQUIRED FOR THIS PROJECT FROM APPROVED SHOP DRAWINGS BEFORE BEGINNING ROUGH-IN. ANY DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER AND GENERAL CONTRACTOR IMMEDIATELY.
4. THE ELECTRICAL CONTRACTOR SHALL NOTIFY AND COOPERATE WITH THE MECHANICAL CONTRACTOR SUCH THAT NO PIPING, DUCTS, OR EQUIPMENT FOREIGN TO THE OPERATION OF THE ELETRICAL EQUIPMENT SHALL BE PERMITTED TO BE INSTALLED IN, ENTER, OR PASS THRU ELECTRICAL ROOMS OR SPACES, OR ABOVE OF BELOW ELECTRICAL EQUIPMENT AS PER N.E.C.
5. COORDINATE ELECTRICAL LIGHTING DRAWINGS WITH ARCHITECTURAL RELFECTED CEILING PLANS AND REPORT ANY DISCREPANCIES TO ARCHITECT/ ENGINEER.
6. FINISHES OF ALL LIGHT FIXTURES SHALL BE SELECTED BY ARCHITECT.7. SEE SPECIFICATION FOR ENERGY SAVING LAMP AND BALLAST REQUIREMENTS.8. SEE APPLICABLE SHOP DRAWINGS FOR ROUGH-IN LOCATION OF ALL EQUIPMENT
WIRING DEVICES, ETC. MOUNT ALL ABOVE COUNTER TOP WIRING DEVICES ABOVE BACKSPLASH EXCEPT THOSE SERVING UNDER COUNTER EQUIPMENT.
9. ALL E.W.C.'S SHALL BE WALL MOUNTED WITH ELECTRICAL CONNECTIONS MADE FROM CONVENIENCE OUTLET, FLUSH MOUNTED IN WALL BEHIND COOLER HOUSING, LOCATE THE JUNCTION BOX FOR ACCESSIBILITY FROM WITHIN COOLER HOUSING.
10. ALL CONDUITS PENETRATING ROOF SHALL BE SEALED WITH PITCH POCKETS.11. ELECTRICAL BOXES SHALL NOT BE LOCATED IN MASONRY COLUMNS, IN BLOCK
WALLS, OR IN GROUTED CELLS ADJACENT TO OPENINGS. COORDINATE LOCATION OF BOXES WITH MASONRY CONTRACTOR.
12. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS, AND CEILINGS BY CONDUITS SHALL BE SEALED WITH APPROVED MATERIAL TO MAINTAIN FIRE RATING OF SURFACES PENETRATED. VERIFY WITH ARCHITECT. ALL LIGHT FIXTURES REQUIRING SHEET ROCK BOOTS TO RETAIN CEILING RATING SHOULD BE COORDINATED WITH GENERAL CONTRACTOR BEFORE BID. SHEET ROCK BOOTS TO BE PROVIDED BY OTHERS.
13. PROVIDE ONE PIECE GALVANIZED FLAT ROLLED SHEET STEEL OUTLET BOXES WITH STAMPED KNOCKOUTS. MINIMUM DEPTH OF 1-1/2" WITH BOXES WITH THREE OF MORE CONDUIT ENTRIES SHALL BE 4-SQUARE WITH 1 OR 2 GANG MUD RING, JUNCTION BOXES SHALL BE SHEET STEEL WITH SCREW-ON COVERS.
14. PROVIDE COLOR CODING FOR CONDUCTORS AS FOLLOWS: BROWN/ORANGE/YELLOW/GRAY FOR 277/480 V AND BLACK/RED/BLUE/WHITE FOR 120/208 V.
15. WHEN CONDUCTOR SIZE IS INDICATED FOR A BRANCH CIRCUIT HOMERUN, THE CONDUCTOR SHALL BE UP SIZED TO OVERCOME VOLTAGE DROP AS PER N.E.C. IF NEEDED.
16. CONDUITS SHALL BE EMT. CONDUITS SHALL BE SUPPORTED WITH CONDUIT CLAMPS TRAPEZE HANGERS AND THREADED ROD ATTACHED TO STRUCTURE AT INTERVALS NOT TO EXCEED 8 FEET. PROVIDE FLEXIBLE CONDUIT WITH GROUND CONDUCTOR BETWEEN DISCONNECT AND MOTOR. PROVIDE EXPANSION FITTINGS AS REQUIRED BY N.E.C.
17. IN SEISMIC AREAS, SUPPORT ALL LIGHT FIXTURES WITH A MINIMUM OF (4) 12 GAUGE STEEL WIRE RUN TO STRUCTURE, FROM NEAR EACH CORNER OF THE LIGHT FIXTURE OR EQUIDISTANT AROUND CIRCULAR LIGHT FIXTURES.
18. CLEAN UP ALL EQUIPMENT, CONDUIT, PACKING CARTONS, ETC. AND OTHER DEBRIS RESULTING FROM THIS INSTALLATION. CLEAN INTERIORS AND EXTERIORS OF ALL EQUIPMENT AND REPLACE, OR REPAIR ALL ELECTRICAL EQUIPMENT UPON REQUEST AT SUBSTANTIAL COMPLETION.
19. DIMENSIONS INDICATING LOCATIONS OF DEVICES ARE TO BE TO THE CENTER OF DEVICE BOX.
20. PROVIDE 1 SPARE 3/4" CONDUIT STUBBED OUT OF EACH FLUSH MOUNTED PANELBOARD FOR EACH 3 SPARE CIRCUITS NOTED ON THE PANEL SCHEDULE. IF PANEL IS LOCATED ON A FLOOR ABOVE GRADE, STUB 1/4 OF THE SPACE CONDUITS DOWN INTO THE ACCESSIBLE CEILING SPACE BELOW THE FLOOR ON WHICH THE PANEL IS LOCATED.
21. PROVIDE SEISMIC BRACING FOR ALL ELECTRICAL EQUIPMENT, CONDUITS, CABLES, LIGHT FIXTURES, CALBE TRAY, ETC. AS PER IBC AND PER SPECIFICATIONS.
22. COORDINATE ALL REQUIRED POWER OUTAGES WITH THE OWNER 14 DAYS IN ADVANCE OF PLANNED OUTAGE.
ELECTRICAL GENERAL NOTESAFFLECK
No. 7083854
DAVID L.
LICENSED
PRO
F ESS I ONAL
ENGINEER
STA T E O F U T
AH
07/11/2019
DATE:
Haro
ld P
. W
oodru
ff A
rchi
tect
\Pla
nner
22
3 E
ast
80
0 S
outh
Salt L
ake
City,
Uta
h 8
4111
Pho
ne:
80
1−3
55
−86
84
7105 HIGHLAND DR., STE. 200SALT LAKE CITY, UTAH 84121
(801) 209-2299
Main O
ffic
e −
Lob
by R
emod
el
Hou
sing
Aut
hority
of
the
Cou
nty
of S
alt L
ake
35
95
Sou
th M
ain S
tree
tSalt L
ake
City,
Uta
h 8
4115
EE001
SYMBOLS,ABBREVIATIONS,GENERAL NOTES
08/01/2019
SHEET INDEX
EE001 SYMBOLS, ABBREVIATIONS, GENERAL NOTES
EP101 DEMO, LIGHTING, AND POWER PLANS
PHOTOCELL CLCEILING
CEILING OCCUPANCY SENSOR; DUAL TECHNOLOGY CLCEILING
DIMMER LIGHT SWITCH AFF48"
FOUR-WAY LIGHT SWITCH AFF48"4
THREE-WAY LIGHT SWITCH AFF48"3
LIGHTING CONTROL DEVICES
SINGLE POLE LIGHT SWITCH AFF48"
THERMAL OVERLOAD SWITCH NAFVMHT
MAGNETIC STARTER WITH INTERNAL DISCONNECT (COMBO) NAFVMH
NON-FUSED DISCONNECT NAFVMH
FUSED DISCONNECT NAFVMH
ELECTRICAL EQUIPMENT CONNECTOR NAFVMH
ELECTRICAL PANELBOARD NAFVMH
EQUIPMENT CALLOUT NANA
ELECTRICAL EQUIPMENT AND MOTOR HOOKUPS
LIGHTING (SEE LIGHT FIXTURE SCHEDULE FOR SPECIFICATIONS)
WALL MOUNTED EXIT LIGHT (SHADED AREA REPRESENTS FACE) WSURFACE
EXIT LIGHT WITH DIRECTIONAL ARROW (SHADED AREA REPRESENTS FACE)
CLVARIES
CEILING MOUNTED EXIT LIGHT (SHADED AREA REPRESENTS FACE) CLVARIES
DOWNLIGHT FIXTURE CLSURFACE
RECESSED CAN FIXTURE CLVARIES
WRAP AROUND FIXTURE CLVARIES
LINEAR PENDANT FIXTURE CLVARIES
LINEAR WALL MOUNT FIXTURE CLVARIES
2'x4' VOLUMETRIC TROFFER CLVARIES
2'x2' LENSED TROFFER CLVARIES
2'x4' LENSED TROFFER CLVARIES
HALF-SHADED LIGHTS REPRESENT AN EMERGENCY LIGHT OR LIGHT FIXTURE WIRED WITH AN EMERGENCY BATTERY PACK
NANA
TELEVISION MONITOR DUPLEX RECEPTACLE AFF72"TV
REFRIGERATOR DUPLEX RECEPTACLE AFF42"REF
DRINKING FOUNTAIN DUPLEX RECEPTACLE AFF18"-30"DF
POWER DEVICES
QUADPLEX RECEPTACLE (110V, 20A, 1Φ) AFF18" OR A
GFCI DUPLEX RECEPTACLE (110V, 20A, 1Φ) AFF18" OR A
DUPLEX RECEPTACLE WITH ISOLATED GROUND (110V, 20A, 1Φ) AFF18" OR AIG
WEATHER PROOF GFCI DUPLEX RECEPTACLE (110V, 20A, 1Φ) AFF18" OR AWP
J JUNCTION BOX NAVARIES
ABOVE COUNTER RECEPTACLE AFFAA
DUPLEX RECEPTACLE (110V, 20A, 1Φ) AFF18" OR A
DESCRIPTION FROMMOUNTINGSYMBOL
ELECTRICAL SYMBOL SCHEDULE
DATA RECEPTACLE AFF18" OR A
COMMUNICATIONS DEVICES
VOICE RECEPTACLE AFF18" OR A
VOICE/DATA RECEPTACLE AFF18" OR A
![Page 9: Render Plus - housingconnect.org...rg-1 eh price pddrrequired to fit ceiling tile space available. damper: none application: air return ... main office - lobby remodel. ... existi對ng](https://reader036.fdocuments.us/reader036/viewer/2022081612/5f15a993fa9e945a816784cb/html5/thumbnails/9.jpg)
106
104
107
105
103
101
108
109
102
INTERVIEWROOM
RECEPTION
INTERVIEWROOM
UNISEXRESTROOM
LOBBY
VESTIBULE
OFFICE AREA
MAINTENANCEVESTIBULE
VESTIBULEINNER
PL
AT
EP
RO
DN
AM
EP
RO
DC
LA
SS
MA
TE
RIA
LK
PG
RIP
GU
SE
R1
US
ER
2U
SE
R3
106
104
107
105
103
101
108
109
102
INTERVIEWROOM
RECEPTION
INTERVIEWROOM
UNISEXRESTROOM
LOBBY
VESTIBULE
OFFICE AREA
MAINTENANCEVESTIBULE
VESTIBULEINNER
PL
AT
EP
RO
DN
AM
EP
RO
DC
LA
SS
MA
TE
RIA
LK
PG
RIP
GU
SE
R1
US
ER
2U
SE
R3
105
103
104
102
101
107
108
102
INTERVIEWROOM
RECEPTION
UNISEXRESTROOM
LOBBY
VESTIBULE
MAINTENANCEVESTIBULE
MAINTENANCEOFFICE
VESTIBULEINNER
S
PL
AT
EP
RO
DN
AM
EP
RO
DC
LA
SS
MA
TE
RIA
LK
PG
RIP
GU
SE
R1
US
ER
2U
SE
R3
EXISTING PANEL F 7
7
7
8
9
9
9
DF
10
NL
VM3E
VM3
VM3
VM3E
VM3
VM3E
VM3E
VM3
VM3E
OS
SW2
SW2
3
3
1
1
1
1
1
1
2
2
2
2
3
4
4
4
4
5
6
6
6
1. EXISTING FIRE ALARM DEVICES IN THE AREA OF WORK SHALL REMAIN IN TACT AND SHALL NOT BE REMOVED. NO CHANGES ARE ANTICIPATED. IF NEW EQUIPMENT (LIGHT FIXTURES, MECHANICAL GRILLS, ETC. CONFLICT WITH EXISTING LAYOUT OF EXISTING FIRE ALARM DEVICES, THEN THE EXISTING FIRE ALARM DEVICES SHALL BE RELOCATED WITHIN THE SPACE TO COMPLY WITH THE REQUIREMENTS OF NFPA 72 FOR PLACEMENT AND COVERAGE. CONTRACTOR SHALL REVIEW ANY CHANGES NECESSARY WITH THE FIRE MARSHAL PRIOR TO RELOCATION OF THE DEVICE(S).
AFFLECK
No. 7083854
DAVID L.
LICENSED
PRO
F ESS I ONAL
ENGINEER
STA T E O F U T
AH
07/11/2019
DATE:
Haro
ld P
. W
oodru
ff A
rchi
tect
\Pla
nner
22
3 E
ast
80
0 S
outh
Salt L
ake
City,
Uta
h 8
4111
Pho
ne:
80
1−3
55
−86
84
7105 HIGHLAND DR., STE. 200SALT LAKE CITY, UTAH 84121
(801) 209-2299
Main O
ffic
e −
Lob
by R
emod
el
Hou
sing
Aut
hority
of
the
Cou
nty
of S
alt L
ake
35
95
Sou
th M
ain S
tree
tSalt L
ake
City,
Uta
h 8
4115
EP101
DEMO, LIGHTING,AND POWER PLANS
08/01/2019
1 CONNECT NEW LIGHTING TO EXISTING CIRCUIT.PROVIDE ADDITIONAL WIRING TO CONNECTUNSWITCHED LEG OF THE CIRCUIT TO THE NIGHTLIGHT FIXTURES (NL) AND THE EMERGENCY BATTERYPACKS IN THE EMERGENCY FIXTURES. PROVIDE NEWMANUAL AND AUTOMATIC LIGHTING CONTROLS ASINDICATED.
2 PROVIDE NEW LOW VOLTAGE LIGHTING CONTROLSWITCHES AND CONTROLLERS FOR EACH ROOM.LIGHTING SHALL BE AUTO OFF/MANUAL ON (VACANCYSENSORS) AND SHALL BE DIMMABLE.
3 RECONNECT EXISTING LIGHTS TO NEW SWITCHES.FIELD VERIFY REQUIREMENTS.
4 DEMO EXISTING LIGHTS SHOWN DASHED (TYPICAL)
5 REMOVE EXISTING POWER DEVICES, JUNCTIONBOXES, AND CONDUITS IN THE WALL TO ACCOMODATETHE NEW WINDOW. REMOVE CIRCUIT WIRING BACKTO THE NEAREST JUNCTION BOX.
6 REMOVE EXISTING LIGHT SWITCH(ES). PROVIDEBLANK COVER PLATES WHERE NEEDED. FIELDVERIFY.
7 CONNECT TO EXISTING POWER CIRCUIT TO THECIRCUIT SERVING OTHER OUTLETS IN THE AREA ORDEVICES THAT WERE DEMOLISHED.
8 PROVIDE POWER OUTLETS IN MILLWORK,COORDINATE WITH MILLWORK INSTALLER. CONDUITSFOR OUTLETS SHALL BE ROUTED IN THE FULL HEIGHTPORTIONS OF THE NEW WALL. FIELD VERIFY.
9 PROVIDE A DOUBLE GANG BACKBOX WITH SINGLEGANG MUD RING AND A 1-INCH CONDUIT STUBBED TOABOVE THE ACCESSIBLE CEILING FOR EACH NEWCOMMUNICATIONS DEVICE SHOWN.
10 PROVIDE CONNECTION TO NEW DRINKING FOUNTAINWITH DEDICATED CIRCUIT BACK TO EXISTING PANEL.PROVIDE A NEW 20A/1P CIRCUIT BREAKER IN THEPANEL TO MATCH THE PANEL TYPE AND AIC RATING,FIELD VERIFY. COORDINATE REQUIREMENTS FOREXACT OUTLET MOUNTING HEIGHT AND LOCATIONWITH DRINKING FOUNTAIN INSTALLER.
#Sheet Keynotes
1/8" = 1'-0"EP101
1 LOBBY POWER PLAN1/8" = 1'-0"EP101
2 LOBBY LIGHTING PLAN1/8" = 1'-0"EP101
3 LOBBY DEMO PLAN
FIXTURE ID FIXTURE DESCRIPTION LAMPS WATTS VOLTAGE MANUFACTURER AND CATALOG NUMBER NOTES
LIGHT FIXTURE SCHEDULE
MOUNTING
THIS LIGHT FIXTURE SCHEDULE IS INTENDED TO PROVIDE A BASIS OF DESIGN FOR FIXTURES TO BE USED. EQUIVALENT FIXTURES MAY BE CONSIDERED WITH PRIOR APPROVAL IN WRITING FROM THE ENGINEER AND OWNER. CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT TO MOUNT FIXTURES PER THE MANUFACTURERS' INSTRUCTION AND INTENTION, WHETHER OR NOT ALL REQUIRED OPTIONS ARE INCLUDED IN THE PART NUMBERS LISTED. THE CONTRACTOR SHALL COORDINATE
PROPER MOUNTING WITH THE SURFACE CONDITION OR MOUNTING REQUIREMENTS OF THE STRUCTURE.
SW2
VM3 RECESSED VOLUMETRIC 2'X4', LED, 4000 LUMENS, DIMMING (0-10V), 3500K LED
VM3ERECESSED VOLUMETRIC 2'X4', LED, 4000 LUMENS, DIMMING (0-10V), 3500K, BATTERY
BACKUPLED
RECESS MOUNT IN ACCESSIBLECEILING
LITHONIA 2VTL4-40L-ADP-MVOLT-EZ1-LP835-EL14LOR APPROVED EQUAL
SURFACE MOUNT LITHONIA LBL4-LP835 OR APPROVED EQUAL
LITHONIA 2VTL4-40L-ADP-MVOLT-EZ1-LP835 OR APPROVED EQUAL
SURFACE MOUNT 1X4 LED FIXTURE, 4000 LUMENS LED
RECESS MOUNT IN ACC CEILING
32
40
40
120
120
120
General Notes