Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack...

11
Marco Li Structure Team 20180525 Rack Server Random Vibration FEA (Femap w/ NX-Nastran)

Transcript of Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack...

Page 1: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

■ Marco Li

■ Structure Team

■ 20180525

Rack Server Random Vibration FEA (Femap w/ NX-Nastran)

Page 2: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

2

Agenda

� Rack Server Random Vibration Specification Introduction

� Rack Level Random Vibration Test

� Rack Level Random Vibration FEA

� Automatic Bolt API Sharing

Page 3: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

3

Scalable

Balanced

Performance Driven

Rack Server Random Vibration Specification Introduction -1

� Product Design Experience

Page 4: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

4

� Transportation

Rack Server Random Vibration Specification Introduction -2

� Specification Introduction

Customer I Customer II Customer III

Modes Truck, Air, Rail and Ocean Vibration

Grms 0.8 1.146 0.84 1.2

Test Orientations Z Z X/Y Z

Duration (min) 15 60 60 60

Highest Grms

Rail

Truck

Air

Ocean

Page 5: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

5

Rack Level Random Vibration Test

� Purpose: Verify rack server structure rigidity under random vibration input.

Rack setup on Vibe. table Testing

Case 1 – 1U rack server test (1.2 Grms) result

Case 2 – 2U rack server test (1.146 Grms) result

Page 6: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

6

Rack Level Random Vibration FEA

� Femap w/ NX-Nastran Random Response Solver

Page 7: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

7

Rack Level Random Vibration FEA – Case 1

Case 1 – 1U rack server test (1.2 Grms) result

� FEA model – Femap w/ NX-Nastran

� FEA result� Stress concentrate on the weak point, FEA

result is similar to rack test result.

Rear Wall

Page 8: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

8

Rack Level Random Vibration FEA – Case 2

� Stress concentrate on the weak point, FEA result is similar to rack test result.

Case 2 – 2U rack server test (1.146 Grms) result

� FEA model – Femap w/ NX-Nastran

� FEA result

Page 9: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

9

Solution Implement Result

� Case 1

� Case 2

Rear Wall with solution

Page 10: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

Backup

Page 11: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress

Automatic Bolt

11

Complete:

1. Select bolt surfaces

2. Enter radius range to search curves on bolted surfaces

Next Action:

3. Automatic search multi-circles which have be bolted

together

4. Automatic fixed by each bolted

Efficiency-(15sec)Current-(41sec)

� Manual Curve Selection � Automatic Select Bolt Circle