Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer...
Transcript of Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer...
![Page 1: Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer Information Packet **Recommended wiring: 18/6 shielded for main device, and 18/4 shielded](https://reader033.fdocuments.us/reader033/viewer/2022042918/5f5dfdf9947d387c6e07f4c8/html5/thumbnails/1.jpg)
front page
Quick Install Guide
CellGate Support: 972-231-1999 option 2
2019
Watchman EVO WXP
1
![Page 2: Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer Information Packet **Recommended wiring: 18/6 shielded for main device, and 18/4 shielded](https://reader033.fdocuments.us/reader033/viewer/2022042918/5f5dfdf9947d387c6e07f4c8/html5/thumbnails/2.jpg)
WXP Details & Supported Devices
WXP
Camera (up to 4) 26-bit Wiegand Devices (Up to 4): Card/RFID/Clicker Reader(s) & Keypad(s)
2
Max Dimensions: 17” x 6” x 12” (in inches)
WXP Unit
Width: 6”
Length: 15”
Length of Antenna: 2”
![Page 3: Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer Information Packet **Recommended wiring: 18/6 shielded for main device, and 18/4 shielded](https://reader033.fdocuments.us/reader033/viewer/2022042918/5f5dfdf9947d387c6e07f4c8/html5/thumbnails/3.jpg)
Items Included in Kit • Unify Unit • 12v / 5 Amp power supply (built in) • Quick Install Guide
• Activation & Test Process • Customer Information Packet
**Recommended wiring: 18/6 shielded for main device, and 18/4 shielded for optional wiegand devices**
WXP Unit
Power Supply Wiring (pre-wired)
Important Item
Expansion Board
Power Supply
Router
Command Module
Fuse Box
Antenna
Enlarged
12v Fuse Terminal Ground
Terminal
WXP
3
![Page 4: Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer Information Packet **Recommended wiring: 18/6 shielded for main device, and 18/4 shielded](https://reader033.fdocuments.us/reader033/viewer/2022042918/5f5dfdf9947d387c6e07f4c8/html5/thumbnails/4.jpg)
Expansion Board
Expansion Board Default Configuration
replace
26-bit Wiegand Input
Default Functionality:
Upon activation of Input 2, Relay 1 will
be activated by default.
Custom configuration available upon request.
Default Functionality:
Upon valid entry of a Wiegand credential,
Relay 1 will be activated by default.
Custom configuration available upon request.
3
Relay 2: Auxiliary Relay
Flashing LED:
Connection successful: Flashing slowly; 1 second on, 1 second off. No communication to the other components in the box: Flashing quickly.
26-bit Wiegand
Connection
Input Plug
Relay Plug
Input 1: Gate/Door Status
Relay 1: Gate/Door
Input 2: Request to Exit (REX)
**All wiring drawn should use 18-gauge cable**
WXP
4
![Page 5: Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer Information Packet **Recommended wiring: 18/6 shielded for main device, and 18/4 shielded](https://reader033.fdocuments.us/reader033/viewer/2022042918/5f5dfdf9947d387c6e07f4c8/html5/thumbnails/5.jpg)
Gate/Door Wiring Diagram
CWU-U320
Power Supply
Enlarged
Gate/Door Trigger
Gate Operator or Dry Contact Door Lock
26-bit Wiegand Keypad Wiring
Gate/Door Status Switch
**All wiring drawn should use 18-gauge cable**
WXP
5
![Page 6: Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer Information Packet **Recommended wiring: 18/6 shielded for main device, and 18/4 shielded](https://reader033.fdocuments.us/reader033/viewer/2022042918/5f5dfdf9947d387c6e07f4c8/html5/thumbnails/6.jpg)
Magnetic Lock Wiring – Normally Open
12v Magnetic
Lock
Enlarged
Normally Open: Set jumper on right 2 pins.
Enlarged
Enlarged
Lock Status Switch
**All wiring drawn should use 18-gauge cable**
WXP
6
![Page 7: Quick Install Guide · • Quick Install Guide • Activation & Test Process • Customer Information Packet **Recommended wiring: 18/6 shielded for main device, and 18/4 shielded](https://reader033.fdocuments.us/reader033/viewer/2022042918/5f5dfdf9947d387c6e07f4c8/html5/thumbnails/7.jpg)
Magnetic Lock Wiring – Normally Closed
Enlarged Enlarged
12v Magnetic
Lock
Lock Status Switch Normally Closed:
Set jumper on left 2 pins.
Enlarged
**All wiring drawn should use 18-gauge cable**
WXP
7